1
|
Li W, Yu R, Xi F. Enhanced Electrochemiluminescence of Luminol and-Dissolved Oxygen by Nanochannel-Confined Au Nanomaterials for Sensitive Immunoassay of Carcinoembryonic Antigen. Molecules 2024; 29:4880. [PMID: 39459248 PMCID: PMC11510663 DOI: 10.3390/molecules29204880] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2024] [Revised: 10/05/2024] [Accepted: 10/09/2024] [Indexed: 10/28/2024] Open
Abstract
Simple development of an electrochemiluminescence (ECL) immunosensor for convenient detection of tumor biomarker is of great significance for early cancer diagnosis, treatment evaluation, and improving patient survival rates and quality of life. In this work, an immunosensor is demonstrated based on an enhanced ECL signal boosted by nanochannel-confined Au nanomaterial, which enables sensitive detection of the tumor biomarker-carcinoembryonic antigen (CEA). Vertically-ordered mesoporous silica film (VMSF) with a nanochannel array and amine groups was rapidly grown on a simple and low-cost indium tin oxide (ITO) electrode using the electrochemically assisted self-assembly (EASA) method. Au nanomaterials were confined in situ on the VMSF through electrodeposition, which catalyzed both the conversion of dissolved oxygen (O2) to reactive oxygen species (ROS) and the oxidation of a luminol emitter and improved the electrode active surface. The ECL signal was enhanced fivefold after Au nanomaterial deposition. The recognitive interface was fabricated by covalent immobilization of the CEA antibody on the outer surface of the VMSF, followed with the blocking of non-specific binding sites. In the presence of CEA, the formed immunocomplex reduced the diffusion of the luminol emitter, resulting in the reduction of the ECL signal. Based on this mechanism, the constructed immunosensor was able to provide sensitive detection of CEA ranging from 1 pg·mL-1 to 100 ng·mL-1 with a low limit of detection (LOD, 0.37 pg·mL-1, S/N = 3). The developed immunosensor exhibited high selectivity and good stability. ECL determination of CEA in fetal bovine serum was achieved.
Collapse
Affiliation(s)
- Weibin Li
- Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Third Hospital of Shanxi Medical University, Taiyuan 030032, China;
| | - Ruliang Yu
- College of Chemistry and Chemical Engineering, Zhejiang Sci-Tech University, Hangzhou 310018, China;
| | - Fengna Xi
- College of Chemistry and Chemical Engineering, Zhejiang Sci-Tech University, Hangzhou 310018, China;
| |
Collapse
|
2
|
Hajjafari A, Sadr S, Rahdar A, Bayat M, Lotfalizadeh N, Dianaty S, Rezaei A, Moghaddam SP, Hajjafari K, Simab PA, Kharaba Z, Borji H, Pandey S. Exploring the integration of nanotechnology in the development and application of biosensors for enhanced detection and monitoring of colorectal cancer. INORG CHEM COMMUN 2024; 164:112409. [DOI: 10.1016/j.inoche.2024.112409] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/19/2024]
|
3
|
Ma Y, Chen R, Zhang R, Liang J, Ren S, Gao Z. Application of DNA-fueled molecular machines in food safety testing. Compr Rev Food Sci Food Saf 2024; 23:1-22. [PMID: 38284608 DOI: 10.1111/1541-4337.13299] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Revised: 12/15/2023] [Accepted: 12/21/2023] [Indexed: 01/30/2024]
Abstract
Food is consumed by humans, which is indispensable to human life. Therefore, considerable attention of the whole society has been paid to food safety. Over the last few years, dramatic social development has brought new challenges to food safety, making developing new and quick methods for on-site food safety testing an important necessity. As a result, DNA-fueled molecular machines, characterized by high efficiency, accuracy, and sensitivity in testing, have come into the spotlight, based on which sensors can be constructed to detect toxic and harmful substances in food products. This study reviewed recent research on several DNA-fueled molecular machines, including DNA tweezers, DNA walkers, and DNA origami, for rapidly detecting toxic and harmful substances. Based on the above studies, the sensitivity and timeliness of several DNA molecular machines were summarized and compared, and the development prospect of DNA fuel molecular machines in the field of food safety detection was prospected.
Collapse
Affiliation(s)
- Yujing Ma
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin, China
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science & Technology, Tianjin, China
| | - Ruipeng Chen
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin, China
| | - Rui Zhang
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin, China
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science & Technology, Tianjin, China
| | - Jun Liang
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science & Technology, Tianjin, China
| | - Shuyue Ren
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin, China
| | - Zhixian Gao
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin, China
| |
Collapse
|
4
|
Xu Y, Zhang Y, Li N, Yang S, Chen J, Hou J, Hou C, Huo D. An ultrasensitive ratiometric electrochemical aptasensor based on metal-organic frameworks and nanoflower-like Bi 2CuO 4 for human epidermal growth factor receptor 2 detection. Bioelectrochemistry 2023; 154:108542. [PMID: 37591183 DOI: 10.1016/j.bioelechem.2023.108542] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2023] [Revised: 07/28/2023] [Accepted: 08/06/2023] [Indexed: 08/19/2023]
Abstract
An ultra-sensitive ratiometric electrochemical aptasensor was constructed based on metal-organic frameworks (MOFs) and bimetallic oxides for the detection of the human epidermal growth factor receptor 2 (HER2), a breast cancer marker. The aluminum metal-organic framework (Al-MOF) and cerium-metal-organic framework (Ce-MOF) have higher specific surface area, which is conducive to load more aptamers or complementary DNA (cDNA), and realize the amplification of internal reference signal Fc. Furthermore, nanoflower-like bismuth copper oxide (Bi2CuO4) with abundant active sites was introduced to modify more aptamers on its surface, which were then fixed to the glassy carbon electrode (GCE) to amplify the detection signal. The quantitative detection of HER2 was achieved by differential pulse voltammetry (DPV), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The materials were characterized by scanning electron microscope, transmission electron microscope, Zeta potential analyzer, X-ray diffraction and X-ray photoelectron spectroscopy. The ratiometric electrochemical aptasensor based on nanomaterial and chain displacement signal amplification technology could discern HER2 in a very wide range (0.001-20.0 ng/mL) with an extremely low detection limit (0.049 pg/mL) and has demonstrated good performance in clinical serum analysis. This strategy also provides a feasible idea for sensitive analysis of other clinical tumor markers.
Collapse
Affiliation(s)
- Ying Xu
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing 400044, PR China
| | - Ya Zhang
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing 400044, PR China
| | - Ning Li
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing 400044, PR China
| | - Siyi Yang
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing 400044, PR China
| | - Jian Chen
- Chongqing University Three Gorges Hospital, Chongqing 404000, PR China
| | - Jingzhou Hou
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing 400044, PR China; Postdoctoral Research Station, Chongqing University, Bioengineering College of Chongqing University, Chongqing 400044, PR China.
| | - Changjun Hou
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing 400044, PR China; Chongqing Key Laboratory of Bio-perception & Intelligent Information Processing, School of Microelectronics and Communication Engineering, Chongqing University, Chongqing 400044, PR China.
| | - Danqun Huo
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing 400044, PR China; Postdoctoral Research Station, Chongqing University, Bioengineering College of Chongqing University, Chongqing 400044, PR China.
| |
Collapse
|
5
|
Shi Y, Li T, Zhao L, Liu Y, Ding K, Li D, He P, Jiang D, Liu J, Zhou H. Ultrathin MXene nanosheet-based TiO2/CdS heterostructure as a photoelectrochemical sensor for detection of CEA in human serum samples. Biosens Bioelectron 2023; 230:115287. [PMID: 37012191 DOI: 10.1016/j.bios.2023.115287] [Citation(s) in RCA: 12] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Revised: 03/18/2023] [Accepted: 03/28/2023] [Indexed: 04/03/2023]
Abstract
To develop highly accurate and ultrasensitive strategies is of great importance for the clinical measurement, in particular, the detection of cancer biomarkers. Herein, we synthesized an ultrasensitive TiO2/MXene/CdS QDs (TiO2/MX/CdS) heterostructure as a photoelectrochemical immunosensor, which favors energy levels matching and fast electron transfer from CdS to TiO2 in the help of ultrathin MXene nanosheet. Dramatic photocurrent quenching can be observed upon incubation of the TiO2/MX/CdS electrode by Cu2+ solution from 96-well microplate, which caused by the formation of CuS and subsequent CuxS (x = 1, 2), reducing the absorption of light and boosting the electron-hole recombination upon irradiation. As a result, the as-prepared biosensor demonstrates a linearly increased photocurrent quenching percentage (Q%) value with CEA concentration ranging from 1 fg/mL to 10 ng/mL, as well as a low detection limit of 0.24 fg/mL. Benefit from its excellent stability, high selectivity and good reproducibility of as-prepared PEC immunosensor, we believe that this proposed strategy might provide new opportunities for clinical diagnosis of CEA and other tumor markers.
Collapse
|
6
|
Yan Q, Zhao G, Wang B, Wang N, Duolihong B, Xia X. Construction of an electrochemical immunosensor based on the OER signal of Au@CoFe-(oxy)hydroxide for ultrasensitive detection of CEA. J Electroanal Chem (Lausanne) 2023. [DOI: 10.1016/j.jelechem.2023.117327] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/17/2023]
|
7
|
Domínguez-Aragón A, Zaragoza-Contreras EA, Figueroa-Miranda G, Offenhäusser A, Mayer D. Electrochemical Immunosensor Using Electroactive Carbon Nanohorns for Signal Amplification for the Rapid Detection of Carcinoembryonic Antigen. BIOSENSORS 2022; 13:bios13010063. [PMID: 36671898 PMCID: PMC9855668 DOI: 10.3390/bios13010063] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Revised: 12/15/2022] [Accepted: 12/22/2022] [Indexed: 05/31/2023]
Abstract
In this work, a novel sandwich-type electrochemical immunosensor was developed for the quantitative detection of the carcinoembryonic antigen, an important tumor marker in clinical tests. The capture antibodies were immobilized on the surface of a gold disk electrode, while detection antibodies were attached to redox-tagged single-walled carbon nanohorns/thionine/AuNPs. Both types of antibody immobilization were carried out through Au-S bonds using the novel photochemical immobilization technique that ensures control over the orientation of the antibodies. The electroactive SWCNH/Thi/AuNPs nanocomposite worked as a signal tag to carry out both the detection of carcinoembryonic antigen and the amplification of the detection signal. The current response was monitored by differential pulse voltammetry. A clear dependence of the thionine redox peak was observed as a function of the carcinoembryonic antigen concentration. A linear detection range from 0.001-200 ng/mL and a low detection limit of 0.1385 pg/mL were obtained for this immunoassay. The results showed that carbon nanohorns represent a promising matrix for signal amplification in sandwich-type electrochemical immune assays working as a conductive and binding matrix with easy and versatile modification routes to antibody and redox tag immobilization, which possesses great potential for clinical diagnostics of CEA and other biomarkers.
Collapse
Affiliation(s)
- Angélica Domínguez-Aragón
- Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, 52428 Jülich, Germany
- Centro de Investigación en Materiales Avanzados, S.C. Miguel de Cervantes 120, Complejo Industrial Chihuahua, Chihuahua 31136, Mexico
| | - Erasto Armando Zaragoza-Contreras
- Centro de Investigación en Materiales Avanzados, S.C. Miguel de Cervantes 120, Complejo Industrial Chihuahua, Chihuahua 31136, Mexico
| | - Gabriela Figueroa-Miranda
- Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, 52428 Jülich, Germany
| | - Andreas Offenhäusser
- Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, 52428 Jülich, Germany
| | - Dirk Mayer
- Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, 52428 Jülich, Germany
| |
Collapse
|