1
|
Nguyen T, Park S, Sodager A, Park J, Gallo DM, Luo G, Romero R, Gandjbakhche A. A Wireless and Wearable Multimodal Sensor to Non-Invasively Monitor Transabdominal Placental Oxygen Saturation and Maternal Physiological Signals. BIOSENSORS 2024; 14:481. [PMID: 39451694 PMCID: PMC11506160 DOI: 10.3390/bios14100481] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/03/2024] [Revised: 09/28/2024] [Accepted: 10/05/2024] [Indexed: 10/26/2024]
Abstract
Poor placental development and placental defects can lead to adverse pregnancy outcomes such as pre-eclampsia, fetal growth restriction, and stillbirth. This study introduces two sensors, which use a near-infrared spectroscopy (NIRS) technique to measure placental oxygen saturation transabdominally. The first one, an NIRS sensor, is a wearable device consisting of multiple NIRS channels. The second one, a Multimodal sensor, which is an upgraded version of the NIRS sensor, is a wireless and wearable device, integrating a motion sensor and multiple NIRS channels. A pilot clinical study was conducted to assess the feasibility of the two sensors in measuring transabdominal placental oxygenation in 36 pregnant women (n = 12 for the NIRS sensor and n = 24 for the Multimodal sensor). Among these subjects, 4 participants had an uncomplicated pregnancy, and 32 patients had either maternal pre-existing conditions/complications, neonatal complications, and/or placental pathologic abnormalities. The study results indicate that the patients with maternal complicated conditions (69.5 ± 5.4%), placental pathologic abnormalities (69.4 ± 4.9%), and neonatal complications (68.0 ± 5.1%) had statistically significantly lower transabdominal placental oxygenation levels than those with an uncomplicated pregnancy (76.0 ± 4.4%) (F (3,104) = 6.6, p = 0.0004). Additionally, this study shows the capability of the Multimodal sensor in detecting the maternal heart rate and respiratory rate, fetal movements, and uterine contractions. These findings demonstrate the feasibility of the two sensors in the real-time continuous monitoring of transabdominal placental oxygenation to detect at-risk pregnancies and guide timely clinical interventions, thereby improving pregnancy outcomes.
Collapse
Affiliation(s)
- Thien Nguyen
- Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, 49 Convent Drive, Bethesda, MD 20892, USA; (T.N.); (S.P.); (J.P.)
| | - Soongho Park
- Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, 49 Convent Drive, Bethesda, MD 20892, USA; (T.N.); (S.P.); (J.P.)
- Laboratory of Vascular Thrombosis and Inflammation, National Heart, Lung, and Blood Institute, National Institutes of Health, 49 Convent Dr., Bethesda, MD 20814, USA
| | - Asma Sodager
- Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, 49 Convent Drive, Bethesda, MD 20892, USA; (T.N.); (S.P.); (J.P.)
| | - Jinho Park
- Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, 49 Convent Drive, Bethesda, MD 20892, USA; (T.N.); (S.P.); (J.P.)
| | - Dahiana M. Gallo
- Department of Obstetrics and Gynecology, Wayne State University School of Medicine, 3990 John R. Street, Detroit, MI 48201, USA;
- Division of Maternal-Fetal Medicine, Department of Obstetrics & Gynecology, St. Luke’s University Health Network, 701 Ostrum Street, Suite 303, Bethlehem, PA 18015, USA
| | - Guoyang Luo
- Obstetrics & Gynecology at the University of Virginia School of Medicine, 1340 Jefferson Park Ave, Charlottesville, VA 22903, USA;
- Department of Obstetrics & Gynecology, Division of Maternal Fetal Medicine, Fairfax Hospital, 3300 Gallows Rd, Falls Church, VA 22042, USA
| | - Roberto Romero
- Pregnancy Research Branch, Division of Obstetrics and Maternal-Fetal Medicine, Division of Intramural Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, U.S. Department of Health and Human Services, Bethesda, MD 20892, USA;
- Department of Obstetrics and Gynecology, University of Michigan, Ann Arbor, MI 48109, USA
- Department of Epidemiology and Biostatistics, Michigan State University, East Lansing, MI 48824, USA
| | - Amir Gandjbakhche
- Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, 49 Convent Drive, Bethesda, MD 20892, USA; (T.N.); (S.P.); (J.P.)
| |
Collapse
|
2
|
Park J, Nguyen T, Park S, Hill B, Shadgan B, Gandjbakhche A. Two-Stream Convolutional Neural Networks for Breathing Pattern Classification: Real-Time Monitoring of Respiratory Disease Patients. Bioengineering (Basel) 2024; 11:709. [PMID: 39061791 PMCID: PMC11273486 DOI: 10.3390/bioengineering11070709] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2024] [Revised: 06/26/2024] [Accepted: 07/11/2024] [Indexed: 07/28/2024] Open
Abstract
A two-stream convolutional neural network (TCNN) for breathing pattern classification has been devised for the continuous monitoring of patients with infectious respiratory diseases. The TCNN consists of a convolutional neural network (CNN)-based autoencoder and classifier. The encoder of the autoencoder generates deep compressed feature maps, which contain the most important information constituting data. These maps are concatenated with feature maps generated by the classifier to classify breathing patterns. The TCNN, single-stream CNN (SCNN), and state-of-the-art classification models were applied to classify four breathing patterns: normal, slow, rapid, and breath holding. The input data consisted of chest tissue hemodynamic responses measured using a wearable near-infrared spectroscopy device on 14 healthy adult participants. Among the classification models evaluated, random forest had the lowest classification accuracy at 88.49%, while the TCNN achieved the highest classification accuracy at 94.63%. In addition, the proposed TCNN performed 2.6% better in terms of classification accuracy than an SCNN (without an autoencoder). Moreover, the TCNN mitigates the issue of declining learning performance with increasing network depth, as observed in the SCNN model. These results prove the robustness of the TCNN in classifying breathing patterns despite using a significantly smaller number of parameters and computations compared to state-of-the-art classification models.
Collapse
Affiliation(s)
- Jinho Park
- Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, 49 Convent Dr., Bethesda, MD 20894, USA; (J.P.); (T.N.); (S.P.); (B.H.)
| | - Thien Nguyen
- Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, 49 Convent Dr., Bethesda, MD 20894, USA; (J.P.); (T.N.); (S.P.); (B.H.)
| | - Soongho Park
- Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, 49 Convent Dr., Bethesda, MD 20894, USA; (J.P.); (T.N.); (S.P.); (B.H.)
- National Heart, Lung and Blood Institute, National Institutes of Health, 10 Center Dr., Bethesda, MD 20892, USA
| | - Brian Hill
- Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, 49 Convent Dr., Bethesda, MD 20894, USA; (J.P.); (T.N.); (S.P.); (B.H.)
| | - Babak Shadgan
- Implantable Biosensing Laboratory, International Collaboration on Repair Discoveries, Vancouver, BC V5Z 1M9, Canada;
- Department of Pathology & Laboratory Medicine, University of British Columbia, Vancouver, BC V6T 1Z7, Canada
| | - Amir Gandjbakhche
- Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, 49 Convent Dr., Bethesda, MD 20894, USA; (J.P.); (T.N.); (S.P.); (B.H.)
| |
Collapse
|
3
|
Hao Z, Wang Y, Li F, Ding G, Gao Y. mmWave-RM: A Respiration Monitoring and Pattern Classification System Based on mmWave Radar. SENSORS (BASEL, SWITZERLAND) 2024; 24:4315. [PMID: 39001094 PMCID: PMC11243972 DOI: 10.3390/s24134315] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/30/2024] [Revised: 06/11/2024] [Accepted: 07/01/2024] [Indexed: 07/16/2024]
Abstract
Breathing is one of the body's most basic functions and abnormal breathing can indicate underlying cardiopulmonary problems. Monitoring respiratory abnormalities can help with early detection and reduce the risk of cardiopulmonary diseases. In this study, a 77 GHz frequency-modulated continuous wave (FMCW) millimetre-wave (mmWave) radar was used to detect different types of respiratory signals from the human body in a non-contact manner for respiratory monitoring (RM). To solve the problem of noise interference in the daily environment on the recognition of different breathing patterns, the system utilised breathing signals captured by the millimetre-wave radar. Firstly, we filtered out most of the static noise using a signal superposition method and designed an elliptical filter to obtain a more accurate image of the breathing waveforms between 0.1 Hz and 0.5 Hz. Secondly, combined with the histogram of oriented gradient (HOG) feature extraction algorithm, K-nearest neighbours (KNN), convolutional neural network (CNN), and HOG support vector machine (G-SVM) were used to classify four breathing modes, namely, normal breathing, slow and deep breathing, quick breathing, and meningitic breathing. The overall accuracy reached up to 94.75%. Therefore, this study effectively supports daily medical monitoring.
Collapse
Affiliation(s)
- Zhanjun Hao
- College of Computer Science and Engineering, Northwest Normal University, Lanzhou 730070, China; (Y.W.); (F.L.); (G.D.); (Y.G.)
- Gansu Province Internet of Things Engineering Research Center, Lanzhou 730070, China
| | - Yue Wang
- College of Computer Science and Engineering, Northwest Normal University, Lanzhou 730070, China; (Y.W.); (F.L.); (G.D.); (Y.G.)
| | - Fenfang Li
- College of Computer Science and Engineering, Northwest Normal University, Lanzhou 730070, China; (Y.W.); (F.L.); (G.D.); (Y.G.)
| | - Guozhen Ding
- College of Computer Science and Engineering, Northwest Normal University, Lanzhou 730070, China; (Y.W.); (F.L.); (G.D.); (Y.G.)
| | - Yifei Gao
- College of Computer Science and Engineering, Northwest Normal University, Lanzhou 730070, China; (Y.W.); (F.L.); (G.D.); (Y.G.)
| |
Collapse
|
4
|
Lingawi S, Hutton J, Khalili M, Shadgan B, Christenson J, Grunau B, Kuo C. Cardiorespiratory Sensors and Their Implications for Out-of-Hospital Cardiac Arrest Detection: A Systematic Review. Ann Biomed Eng 2024; 52:1136-1158. [PMID: 38358559 DOI: 10.1007/s10439-024-03442-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2023] [Accepted: 01/03/2024] [Indexed: 02/16/2024]
Abstract
Out-of-hospital cardiac arrest (OHCA) is a major health problem, with a poor survival rate of 2-11%. For the roughly 75% of OHCAs that are unwitnessed, survival is approximately 2-4.4%, as there are no bystanders present to provide life-saving interventions and alert Emergency Medical Services. Sensor technologies may reduce the number of unwitnessed OHCAs through automated detection of OHCA-associated physiological changes. However, no technologies are widely available for OHCA detection. This review identifies research and commercial technologies developed for cardiopulmonary monitoring that may be best suited for use in the context of OHCA, and provides recommendations for technology development, testing, and implementation. We conducted a systematic review of published studies along with a search of grey literature to identify technologies that were able to provide cardiopulmonary monitoring, and could be used to detect OHCA. We searched MEDLINE, EMBASE, Web of Science, and Engineering Village using MeSH keywords. Following inclusion, we summarized trends and findings from included studies. Our searches retrieved 6945 unique publications between January, 1950 and May, 2023. 90 studies met the inclusion criteria. In addition, our grey literature search identified 26 commercial technologies. Among included technologies, 52% utilized electrocardiography (ECG) and 40% utilized photoplethysmography (PPG) sensors. Most wearable devices were multi-modal (59%), utilizing more than one sensor simultaneously. Most included devices were wearable technologies (84%), with chest patches (22%), wrist-worn devices (18%), and garments (14%) being the most prevalent. ECG and PPG sensors are heavily utilized in devices for cardiopulmonary monitoring that could be adapted to OHCA detection. Developers seeking to rapidly develop methods for OHCA detection should focus on using ECG- and/or PPG-based multimodal systems as these are most prevalent in existing devices. However, novel sensor technology development could overcome limitations in existing sensors and could serve as potential additions to or replacements for ECG- and PPG-based devices.
Collapse
Affiliation(s)
- Saud Lingawi
- British Columbia Resuscitation Research Collaborative, Vancouver, BC, Canada.
- School of Biomedical Engineering, University of British Columbia, Vancouver, BC, Canada.
- Centre for Aging SMART, University of British Columbia, 2635 Laurel St., Vancouver, BC, V5Z 1M9, Canada.
| | - Jacob Hutton
- British Columbia Resuscitation Research Collaborative, Vancouver, BC, Canada
- British Columbia Emergency Health Services, Vancouver, Canada
- Department of Emergency Medicine, University of British Columbia and St. Paul's Hospital, Vancouver, BC, Canada
- Centre for Advancing Health Outcomes, University of British Columbia, Vancouver, BC, Canada
| | - Mahsa Khalili
- British Columbia Resuscitation Research Collaborative, Vancouver, BC, Canada
- Centre for Aging SMART, University of British Columbia, 2635 Laurel St., Vancouver, BC, V5Z 1M9, Canada
- Department of Emergency Medicine, University of British Columbia and St. Paul's Hospital, Vancouver, BC, Canada
- Centre for Advancing Health Outcomes, University of British Columbia, Vancouver, BC, Canada
| | - Babak Shadgan
- British Columbia Resuscitation Research Collaborative, Vancouver, BC, Canada
- School of Biomedical Engineering, University of British Columbia, Vancouver, BC, Canada
- Department of Orthopedic Surgery, University of British Columbia, Vancouver, BC, Canada
- International Collaboration on Repair Discoveries, Vancouver, BC, Canada
| | - Jim Christenson
- British Columbia Resuscitation Research Collaborative, Vancouver, BC, Canada
- British Columbia Emergency Health Services, Vancouver, Canada
- Department of Emergency Medicine, University of British Columbia and St. Paul's Hospital, Vancouver, BC, Canada
- Centre for Advancing Health Outcomes, University of British Columbia, Vancouver, BC, Canada
| | - Brian Grunau
- British Columbia Resuscitation Research Collaborative, Vancouver, BC, Canada
- British Columbia Emergency Health Services, Vancouver, Canada
- Department of Emergency Medicine, University of British Columbia and St. Paul's Hospital, Vancouver, BC, Canada
- Centre for Advancing Health Outcomes, University of British Columbia, Vancouver, BC, Canada
| | - Calvin Kuo
- British Columbia Resuscitation Research Collaborative, Vancouver, BC, Canada
- School of Biomedical Engineering, University of British Columbia, Vancouver, BC, Canada
- Centre for Aging SMART, University of British Columbia, 2635 Laurel St., Vancouver, BC, V5Z 1M9, Canada
| |
Collapse
|
5
|
Park J, Mah AJ, Nguyen T, Park S, Ghazi Zadeh L, Shadgan B, Gandjbakhche AH. Modification of a Conventional Deep Learning Model to Classify Simulated Breathing Patterns: A Step toward Real-Time Monitoring of Patients with Respiratory Infectious Diseases. SENSORS (BASEL, SWITZERLAND) 2023; 23:5592. [PMID: 37420758 PMCID: PMC10300752 DOI: 10.3390/s23125592] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Revised: 06/08/2023] [Accepted: 06/13/2023] [Indexed: 07/09/2023]
Abstract
The emergence of the global coronavirus pandemic in 2019 (COVID-19 disease) created a need for remote methods to detect and continuously monitor patients with infectious respiratory diseases. Many different devices, including thermometers, pulse oximeters, smartwatches, and rings, were proposed to monitor the symptoms of infected individuals at home. However, these consumer-grade devices are typically not capable of automated monitoring during both day and night. This study aims to develop a method to classify and monitor breathing patterns in real-time using tissue hemodynamic responses and a deep convolutional neural network (CNN)-based classification algorithm. Tissue hemodynamic responses at the sternal manubrium were collected in 21 healthy volunteers using a wearable near-infrared spectroscopy (NIRS) device during three different breathing conditions. We developed a deep CNN-based classification algorithm to classify and monitor breathing patterns in real time. The classification method was designed by improving and modifying the pre-activation residual network (Pre-ResNet) previously developed to classify two-dimensional (2D) images. Three different one-dimensional CNN (1D-CNN) classification models based on Pre-ResNet were developed. By using these models, we were able to obtain an average classification accuracy of 88.79% (without Stage 1 (data size reducing convolutional layer)), 90.58% (with 1 × 3 Stage 1), and 91.77% (with 1 × 5 Stage 1).
Collapse
Affiliation(s)
- Jinho Park
- Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, 49 Convent Dr., Bethesda, MD 20894, USA; (J.P.); (T.N.); (S.P.)
| | - Aaron James Mah
- Implantable Biosensing Laboratory, International Collaboration on Repair Discoveries, Vancouver, BC V5Z 1M9, Canada; (A.J.M.); (L.G.Z.); (B.S.)
- Department of Pathology & Laboratory Medicine, University of British Columbia, Vancouver, BC V6T 1Z7, Canada
| | - Thien Nguyen
- Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, 49 Convent Dr., Bethesda, MD 20894, USA; (J.P.); (T.N.); (S.P.)
| | - Soongho Park
- Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, 49 Convent Dr., Bethesda, MD 20894, USA; (J.P.); (T.N.); (S.P.)
| | - Leili Ghazi Zadeh
- Implantable Biosensing Laboratory, International Collaboration on Repair Discoveries, Vancouver, BC V5Z 1M9, Canada; (A.J.M.); (L.G.Z.); (B.S.)
- Department of Pathology & Laboratory Medicine, University of British Columbia, Vancouver, BC V6T 1Z7, Canada
| | - Babak Shadgan
- Implantable Biosensing Laboratory, International Collaboration on Repair Discoveries, Vancouver, BC V5Z 1M9, Canada; (A.J.M.); (L.G.Z.); (B.S.)
- Department of Pathology & Laboratory Medicine, University of British Columbia, Vancouver, BC V6T 1Z7, Canada
| | - Amir H. Gandjbakhche
- Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, 49 Convent Dr., Bethesda, MD 20894, USA; (J.P.); (T.N.); (S.P.)
| |
Collapse
|