1
|
Ambrin G, Cai S, Singh BR. Critical analysis in the advancement of cell-based assays for botulinum neurotoxin. Crit Rev Microbiol 2023; 49:1-17. [PMID: 35212259 DOI: 10.1080/1040841x.2022.2035315] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
The study on botulinum neurotoxins (BoNTs) has rapidly evolved for their structure and functions as opposed to them being poisons or cures. Since their discoveries, the scientific community has come a long way in understanding BoNTs' structure and biological activity. Given its current application as a tool for understanding neurocellular activity and as a drug against over 800 neurological disorders, relevant and sensitive assays have become critical for biochemical, physiological, and pharmacological studies. The natural entry of the toxin being ingestion, it has also become important to examine its mechanism while crossing the epithelial cell barrier. Several techniques and methodologies have been developed, for its entry, pharmacokinetics, and biological activity for identification, and drug efficacy both in vivo and in vitro conditions. However, each of them presents its own challenges. The cell-based assay is a platform that exceeds the sensitivity of mouse bioassay while encompassing all the steps of intoxication including cell binding, transcytosis, endocytosis, translocation and proteolytic activity. In this article we review in detail both the neuronal and nonneuronal based cellular interaction of BoNT involving its transportation, and interaction with the targeted cells, and intracellular activities.
Collapse
Affiliation(s)
- Ghuncha Ambrin
- Department of Biomedical Engineering and Biotechnology, University of Massachusetts, Dartmouth, MA, USA.,Department of Chemistry and Biochemistry, University of Massachusetts, Dartmouth, MA, USA
| | - Shuowei Cai
- Department of Chemistry and Biochemistry, University of Massachusetts, Dartmouth, MA, USA
| | - Bal Ram Singh
- Institute of Advanced Sciences, Botulinum Research Center, Dartmouth, MA, USA
| |
Collapse
|
2
|
Rasetti-Escargueil C, Popoff MR. Recent Developments in Botulinum Neurotoxins Detection. Microorganisms 2022; 10:microorganisms10051001. [PMID: 35630444 PMCID: PMC9145529 DOI: 10.3390/microorganisms10051001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2022] [Revised: 04/29/2022] [Accepted: 05/03/2022] [Indexed: 02/04/2023] Open
Abstract
Botulinum neurotoxins (BoNTs) are produced as protein complexes by bacteria of the genus Clostridium that are Gram-positive, anaerobic and spore forming (Clostridium botulinum, C. butyricum, C. baratii and C. argentinense spp.). BoNTs show a high immunological and genetic diversity. Therefore, fast, precise, and more reliable detection methods are still required to monitor outbreaks and ensure surveillance of botulism. The botulinum toxin field also comprises therapeutic uses, basic research studies and biodefense issues. This review presents currently available detection methods, and new methods offering the potential of enhanced precision and reproducibility. While the immunological methods offer a range of benefits, such as rapid analysis time, reproducibility and high sensitivity, their implementation is subject to the availability of suitable tools and reagents, such as specific antibodies. Currently, the mass spectrometry approach is the most sensitive in vitro method for a rapid detection of active or inactive forms of BoNTs. However, these methods require inter-laboratory validation before they can be more widely implemented in reference laboratories. In addition, these surrogate in vitro models also require full validation before they can be used as replacement bioassays of potency. Cell-based assays using neuronal cells in culture recapitulate all functional steps of toxin activity, but are still at various stages of development; they are not yet sufficiently robust, due to high batch-to-batch cell variability. Cell-based assays have a strong potential to replace the mouse bioassay (MBA) in terms of BoNT potency determination in pharmaceutical formulations; they can also help to identify suitable inhibitors while reducing the number of animals used. However, the development of safe countermeasures still requires the use of in vivo studies to complement in vitro immunological or cell-based approaches.
Collapse
|
3
|
Kumar DN, Baider Z, Elad D, Blum SE, Shtenberg G. Botulinum Neurotoxin C Dual Detection through Immunological Recognition and Endopeptidase Activity Using Porous Silicon Interferometers. Anal Chem 2022; 94:5927-5936. [PMID: 35385264 DOI: 10.1021/acs.analchem.2c00255] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Botulinum neurotoxins (BoNTs) are the most potent toxins known in nature produced by Clostridium botulinum strains, which can cause life-threatening diseases in both humans and animals. The latter is of serious environmental and economic concern, resulting in high mortality, production losses, and rejection of contaminated animal feed. The available in vivo mouse assay is inadequate for real-time and on-site assessment of outbreaks. Herein, we present a reflective-based approach for the detection of BoNT/C while estimating its activity. Two adjacent porous Si Fabry-Pérot interferometers are simultaneously utilized to quantify minute BoNT/C concentrations by a competitive immunoassay and to assess their endopeptidase activity. The reflectivity signals of each interferometer are amplified by biochemical reaction products infiltration into the scaffold or by peptide fragments detachment from the nanostructure. The optical assay is highly sensitive in compliance with the in vivo approach by presenting a detection limit of 4.24 pg mL-1. The specificity and selectivity of the designed platform are cross-validated against BoNT/B and BoNT/D, also relevant to animal health. Finally, the analytical performances of both interferometers for real-life scenarios are confirmed using actual toxins while depicting excellent compliance to complex media analysis. Overall, the presented sensing scheme offers an efficient, rapid, and label-free approach for potential biodiagnostic elucidation of botulism outbreaks.
Collapse
Affiliation(s)
- D Nanda Kumar
- Institute of Agricultural Engineering, ARO, Volcani Institute, Rishon LeZion 7505101, Israel
| | - Zina Baider
- Botulism National Reference Laboratory, Department of Bacteriology, Kimron Veterinary Institute, Bet Dagan 50200, Israel
| | - Daniel Elad
- Botulism National Reference Laboratory, Department of Bacteriology, Kimron Veterinary Institute, Bet Dagan 50200, Israel
| | - Shlomo E Blum
- Botulism National Reference Laboratory, Department of Bacteriology, Kimron Veterinary Institute, Bet Dagan 50200, Israel
| | - Giorgi Shtenberg
- Institute of Agricultural Engineering, ARO, Volcani Institute, Rishon LeZion 7505101, Israel
| |
Collapse
|
4
|
Rapid Detection of Clostridium botulinum in Food Using Loop-Mediated Isothermal Amplification (LAMP). INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:ijerph18094401. [PMID: 33919101 PMCID: PMC8122632 DOI: 10.3390/ijerph18094401] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/30/2021] [Revised: 04/16/2021] [Accepted: 04/17/2021] [Indexed: 12/13/2022]
Abstract
Botulinum neurotoxins are considered as one of the most potent toxins and are produced by Clostridium botulinum. It is crucial to have a rapid and sensitive method to detect the bacterium Clostridium botulinum in food. In this study, a rapid detection assay of C. botulinum in food using loop-mediated isothermal amplification (LAMP) technology was developed. The optimal primers were identified among three sets of primers designed specifically based on the partial ntnh gene encoding nontoxic-nonhaemagglutinin (NTNH) for rapid detection of the target DNA in plasmids. The optimal temperature and reaction time of the LAMP assay were determined to be 64 °C and 60 min, respectively. The chemical kit could be assembled based on these optimized reaction conditions for quick, initial high-throughput screening of C. botulinum in food samples. The established LAMP assay showed high specificity and sensitivity in detecting the target DNA with a limit of 0.0001 pg/ul (i.e., ten times more sensitive than that of the PCR method) and an accuracy rate of 100%. This study demonstrated a potentially rapid, cost-effective, and easy-operating method to detect C. botulinum in food and clinical samples based on LAMP technology.
Collapse
|
5
|
Toxemia in Human Naturally Acquired Botulism. Toxins (Basel) 2020; 12:toxins12110716. [PMID: 33202855 PMCID: PMC7697460 DOI: 10.3390/toxins12110716] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2020] [Revised: 11/07/2020] [Accepted: 11/10/2020] [Indexed: 12/18/2022] Open
Abstract
Human botulism is a severe disease characterized by flaccid paralysis and inhibition of certain gland secretions, notably salivary secretions, caused by inhibition of neurotransmitter release. Naturally acquired botulism occurs in three main forms: food-borne botulism by ingestion of preformed botulinum neurotoxin (BoNT) in food, botulism by intestinal colonization (infant botulism and intestinal toxemia botulism in infants above one year and adults), and wound botulism. A rapid laboratory confirmation of botulism is required for the appropriate management of patients. Detection of BoNT in the patient's sera is the most direct way to address the diagnosis of botulism. Based on previous published reports, botulinum toxemia was identified in about 70% of food-borne and wound botulism cases, and only in about 28% of infant botulism cases, in which the diagnosis is mainly confirmed from stool sample investigation. The presence of BoNT in serum depends on the BoNT amount ingested with contaminated food or produced locally in the intestine or wound, and the timeframe between serum sampling and disease onset. BoNT levels in patient's sera are most frequently low, requiring a highly sensitive method of detection. Mouse bioassay is still the most used method of botulism identification from serum samples. However, in vitro methods based on BoNT endopeptidase activity with detection by mass spectrometry or immunoassay have been developed and depending on BoNT type, are more sensitive than the mouse bioassay. These new assays show high specificity for individual BoNT types and allow more accurate differentiation between positive toxin sera from botulism and autoimmune neuropathy patients.
Collapse
|
6
|
Lonati D, Schicchi A, Crevani M, Buscaglia E, Scaravaggi G, Maida F, Cirronis M, Petrolini VM, Locatelli CA. Foodborne Botulism: Clinical Diagnosis and Medical Treatment. Toxins (Basel) 2020; 12:toxins12080509. [PMID: 32784744 PMCID: PMC7472133 DOI: 10.3390/toxins12080509] [Citation(s) in RCA: 37] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Revised: 08/04/2020] [Accepted: 08/06/2020] [Indexed: 12/14/2022] Open
Abstract
Botulinum neurotoxins (BoNTs) produced by Clostridia species are the most potent identified natural toxins. Classically, the toxic neurological syndrome is characterized by an (afebrile) acute symmetric descending flaccid paralysis. The most know typical clinical syndrome of botulism refers to the foodborne form. All different forms are characterized by the same symptoms, caused by toxin-induced neuromuscular paralysis. The diagnosis of botulism is essentially clinical, as well as the decision to apply the specific antidotal treatment. The role of the laboratory is mandatory to confirm the clinical suspicion in relation to regulatory agencies, to identify the BoNTs involved and the source of intoxication. The laboratory diagnosis of foodborne botulism is based on the detection of BoNTs in clinical specimens/food samples and the isolation of BoNT from stools. Foodborne botulism intoxication is often underdiagnosed; the initial symptoms can be confused with more common clinical conditions (i.e., stroke, myasthenia gravis, Guillain–Barré syndrome—Miller–Fisher variant, Eaton–Lambert syndrome, tick paralysis and shellfish or tetrodotoxin poisoning). The treatment includes procedures for decontamination, antidote administration and, when required, support of respiratory function; few differences are related to the different way of exposure.
Collapse
Affiliation(s)
- Davide Lonati
- Correspondence: ; Tel.: +39-0382-26261; Fax: +39-0382-24605
| | | | | | | | | | | | | | | | | |
Collapse
|
7
|
T U V, Ghosh S, Milleman A, Nguyen T, Ahn CH. A new polymer lab-on-a-chip (LOC) based on a microfluidic capillary flow assay (MCFA) for detecting unbound cortisol in saliva. LAB ON A CHIP 2020; 20:1961-1974. [PMID: 32347263 DOI: 10.1039/d0lc00071j] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Unbound cortisol in saliva, which can be detected with non-invasive sampling, is now considered as one of the most effective biomarkers for the biochemical evaluation of common mental disorders. In this work, a new polymer lab-on-a-chip (LOC) based on a microfluidic capillary flow assay (MCFA) with on-chip dried reagents was newly developed and fully characterized for the detection of unbound cortisol in saliva. The new MCFA device consisted of serially connected microchannels for sample loading, dried detection antibodies, time delay for incubation time control, a spiral reaction chamber for testing, positive and negative controls, and a capillary pump for waste fluid collection. In addition, a portable fluorescence analyzer was also developed for the rapid quantitative measurement of salivary cortisol with high accuracy. A linear dynamic range of 7.0 pg mL-1-16.0 ng mL-1 was achieved from spiked artificial saliva samples with an inter-chip CV of around 4.0% using the developed LOC and fluorescence analyzer. The achieved results support the effective biochemical analysis of common mental disorders such as chronic stress, depression, anxiety and post traumatic stress disorder (PTSD). The new LOC based on a microfluidic capillary flow assay (MCFA) developed in this work can be one of the most promising LOC platforms for high-sensitivity and quantitative POCT with saliva and blood plasma/serum samples.
Collapse
Affiliation(s)
- Vinitha T U
- Microsystems and BioMEMS Laboratory, Department of Electrical Engineering and Computing Systems, University of Cincinnati, Cincinnati, OH 45221, USA.
| | - Sthitodhi Ghosh
- Microsystems and BioMEMS Laboratory, Department of Electrical Engineering and Computing Systems, University of Cincinnati, Cincinnati, OH 45221, USA.
| | - Alexander Milleman
- Microsystems and BioMEMS Laboratory, Department of Electrical Engineering and Computing Systems, University of Cincinnati, Cincinnati, OH 45221, USA.
| | - Thinh Nguyen
- Microsystems and BioMEMS Laboratory, Department of Electrical Engineering and Computing Systems, University of Cincinnati, Cincinnati, OH 45221, USA.
| | - Chong H Ahn
- Microsystems and BioMEMS Laboratory, Department of Electrical Engineering and Computing Systems, University of Cincinnati, Cincinnati, OH 45221, USA.
| |
Collapse
|
8
|
Rudnicka K, Durka K, Chwaluk P, Chmiela M. Metody stosowane do wykrywania i identyfikacji toksyn botulinowych w próbkach klinicznych i żywności*. POSTEP HIG MED DOSW 2020. [DOI: 10.5604/01.3001.0014.1439] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Botulism is a severe neuroparalytic illness, which affects the nervous system. It is caused by botulinum neurotoxins (BoNTs), produced by anaerobic gram-positive bacteria Clostridium botulinum. There are 7 serotypes of BoNT A-G, but BoNT A/B/D/E plays a major role in botulism affecting humans. Foodborne botulism (classic botulism) is the most frequent
clinical manifestation occurring after consumption of food containing botulinum neurotoxins.
The diagnosis of botulism is based on clinical symptoms; however, recommended
and alternative laboratory methods are used to confirm the etiology of symptoms and the
identification of BoNT toxin type. The aim of this work was to present the epidemiology of
foodborne botulism in Poland and to gather and analyze the available diagnostic methods
that allow us to detect BoNT in clinical samples. Using the epidemiological reports of National
Institute of Hygiene in Poland and findings presented in the Przegląd Epidemiologiczny,
the incidence of classical botulism in Poland has been presented over a period of recent
18 years. Searching for the optimal diagnostic method for BoNT identification in various
samples, we have confronted the sensitivity and specificity of recently available alternative
methods with classical biological assay.
Collapse
Affiliation(s)
- Karolina Rudnicka
- Pracownia Gastroimmunologii, Katedra Immunologii i Biologii Infekcyjnej, Wydział Biologii i Ochrony Środowiska, Uniwersytet Łódzki
| | - Karolina Durka
- Pracownia Gastroimmunologii, Katedra Immunologii i Biologii Infekcyjnej, Wydział Biologii i Ochrony Środowiska, Uniwersytet Łódzki
| | - Paweł Chwaluk
- Wojewódzki Szpital Specjalistyczny w Białej Podlaskiej, Biała Podlaska
| | - Magdalena Chmiela
- Pracownia Gastroimmunologii, Katedra Immunologii i Biologii Infekcyjnej, Wydział Biologii i Ochrony Środowiska, Uniwersytet Łódzki
| |
Collapse
|
9
|
Real-Time Monitoring of a Botulinum Neurotoxin Using All-Carbon Nanotube-Based Field-Effect Transistor Devices. SENSORS 2018; 18:s18124235. [PMID: 30513867 PMCID: PMC6308983 DOI: 10.3390/s18124235] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/12/2018] [Revised: 11/23/2018] [Accepted: 11/27/2018] [Indexed: 02/01/2023]
Abstract
The possibility of exposure to botulinum neurotoxin (BoNT), a powerful and potential bioterrorism agent, is considered to be ever increasing. The current gold-standard assay, live-mouse lethality, exhibits high sensitivity but has limitations including long assay times, whereas other assays evince rapidity but lack factors such as real-time monitoring or portability. In this study, we aimed to devise a novel detection system that could detect BoNT at below-nanomolar concentrations in the form of a stretchable biosensor. We used a field-effect transistor with a p-type channel and electrodes, along with a channel comprising aligned carbon nanotube layers to detect the type E light chain of BoNT (BoNT/E-Lc). The detection of BoNT/E-Lc entailed observing the cleavage of a unique peptide and the specific bonding between BoNT/E-Lc and antibody BoNT/E-Lc (Anti-BoNT/E-Lc). The unique peptide was cleaved by 60 pM BoNT/E-Lc; notably, 52 fM BoNT/E-Lc was detected within 1 min in the device with the antibody in the bent state. These results demonstrated that an all-carbon nanotube-based device (all-CNT-based device) could be produced without a complicated fabrication process and could be used as a biosensor with high sensitivity, suggesting its potential development as a wearable BoNT biosensor.
Collapse
|
10
|
Tam CC, Flannery AR, Cheng LW. A Rapid, Sensitive, and Portable Biosensor Assay for the Detection of Botulinum Neurotoxin Serotype A in Complex Food Matrices. Toxins (Basel) 2018; 10:toxins10110476. [PMID: 30445734 PMCID: PMC6266793 DOI: 10.3390/toxins10110476] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2018] [Revised: 11/09/2018] [Accepted: 11/12/2018] [Indexed: 12/14/2022] Open
Abstract
Botulinum neurotoxin (BoNT) intoxication can lead to the disease botulism, characterized by flaccid muscle paralysis that can cause respiratory failure and death. Due to the significant morbidity and mortality costs associated with BoNTs high toxicity, developing highly sensitive, rapid, and field-deployable assays are critically important to protect the nation’s food supply against either accidental or intentional contamination. We report here that the B-cell based biosensor assay CANARY® (Cellular Analysis and Notification of Antigen Risks and Yields) Zephyr detects BoNT/A holotoxin at limits of detection (LOD) of 10.0 ± 2.5 ng/mL in assay buffer. Milk matrices (whole milk, 2% milk and non-fat milk) with BoNT/A holotoxin were detected at similar levels (7.4–7.9 ng/mL). BoNT/A complex was positive in carrot, orange, and apple juices at LODs of 32.5–75.0 ng/mL. The detection of BoNT/A complex in solid complex foods (ground beef, smoked salmon, green bean baby puree) ranged from 14.8 ng/mL to 62.5 ng/mL. Detection of BoNT/A complex in the viscous liquid egg matrix required dilution in assay buffer and gave a LOD of 171.9 ± 64.7 ng/mL. These results show that the CANARY® Zephyr assay can be a highly useful qualitative tool in environmental and food safety surveillance programs.
Collapse
Affiliation(s)
- Christina C Tam
- Foodborne Toxin Detection and Prevention Research Unit, Western Regional Research Center, Agricultural Research Services, United States Department of Agriculture, 800 Buchanan Street, Albany, CA 94710, USA.
| | | | - Luisa W Cheng
- Foodborne Toxin Detection and Prevention Research Unit, Western Regional Research Center, Agricultural Research Services, United States Department of Agriculture, 800 Buchanan Street, Albany, CA 94710, USA.
| |
Collapse
|
11
|
Walper SA, Lasarte Aragonés G, Sapsford KE, Brown CW, Rowland CE, Breger JC, Medintz IL. Detecting Biothreat Agents: From Current Diagnostics to Developing Sensor Technologies. ACS Sens 2018; 3:1894-2024. [PMID: 30080029 DOI: 10.1021/acssensors.8b00420] [Citation(s) in RCA: 85] [Impact Index Per Article: 14.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Although a fundamental understanding of the pathogenicity of most biothreat agents has been elucidated and available treatments have increased substantially over the past decades, they still represent a significant public health threat in this age of (bio)terrorism, indiscriminate warfare, pollution, climate change, unchecked population growth, and globalization. The key step to almost all prevention, protection, prophylaxis, post-exposure treatment, and mitigation of any bioagent is early detection. Here, we review available methods for detecting bioagents including pathogenic bacteria and viruses along with their toxins. An introduction placing this subject in the historical context of previous naturally occurring outbreaks and efforts to weaponize selected agents is first provided along with definitions and relevant considerations. An overview of the detection technologies that find use in this endeavor along with how they provide data or transduce signal within a sensing configuration follows. Current "gold" standards for biothreat detection/diagnostics along with a listing of relevant FDA approved in vitro diagnostic devices is then discussed to provide an overview of the current state of the art. Given the 2014 outbreak of Ebola virus in Western Africa and the recent 2016 spread of Zika virus in the Americas, discussion of what constitutes a public health emergency and how new in vitro diagnostic devices are authorized for emergency use in the U.S. are also included. The majority of the Review is then subdivided around the sensing of bacterial, viral, and toxin biothreats with each including an overview of the major agents in that class, a detailed cross-section of different sensing methods in development based on assay format or analytical technique, and some discussion of related microfluidic lab-on-a-chip/point-of-care devices. Finally, an outlook is given on how this field will develop from the perspective of the biosensing technology itself and the new emerging threats they may face.
Collapse
Affiliation(s)
- Scott A. Walper
- Center for Bio/Molecular Science and Engineering, Code 6900, U.S. Naval Research Laboratory, Washington, D.C. 20375, United States
| | - Guillermo Lasarte Aragonés
- Center for Bio/Molecular Science and Engineering, Code 6900, U.S. Naval Research Laboratory, Washington, D.C. 20375, United States
- College of Science, George Mason University Fairfax, Virginia 22030, United States
| | - Kim E. Sapsford
- OMPT/CDRH/OIR/DMD Bacterial Respiratory and Medical Countermeasures Branch, U.S. Food and Drug Administration, Silver Spring, Maryland 20993, United States
| | - Carl W. Brown
- Center for Bio/Molecular Science and Engineering, Code 6900, U.S. Naval Research Laboratory, Washington, D.C. 20375, United States
- College of Science, George Mason University Fairfax, Virginia 22030, United States
| | - Clare E. Rowland
- Center for Bio/Molecular Science and Engineering, Code 6900, U.S. Naval Research Laboratory, Washington, D.C. 20375, United States
- National Research Council, Washington, D.C. 20036, United States
| | - Joyce C. Breger
- Center for Bio/Molecular Science and Engineering, Code 6900, U.S. Naval Research Laboratory, Washington, D.C. 20375, United States
| | - Igor L. Medintz
- Center for Bio/Molecular Science and Engineering, Code 6900, U.S. Naval Research Laboratory, Washington, D.C. 20375, United States
| |
Collapse
|
12
|
Thirunavukkarasu N, Johnson E, Pillai S, Hodge D, Stanker L, Wentz T, Singh B, Venkateswaran K, McNutt P, Adler M, Brown E, Hammack T, Burr D, Sharma S. Botulinum Neurotoxin Detection Methods for Public Health Response and Surveillance. Front Bioeng Biotechnol 2018; 6:80. [PMID: 29988463 PMCID: PMC6024544 DOI: 10.3389/fbioe.2018.00080] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2018] [Accepted: 05/30/2018] [Indexed: 01/06/2023] Open
Abstract
Botulism outbreak due to consumption of food contaminated with botulinum neurotoxins (BoNTs) is a public health emergency. The threat of bioterrorism through deliberate distribution in food sources and/or aerosolization of BoNTs raises global public health and security concerns due to the potential for high mortality and morbidity. Rapid and reliable detection methods are necessary to support clinical diagnosis and surveillance for identifying the source of contamination, performing epidemiological analysis of the outbreak, preventing and responding to botulism outbreaks. This review considers the applicability of various BoNT detection methods and examines their fitness-for-purpose in safeguarding the public health and security goals.
Collapse
Affiliation(s)
- Nagarajan Thirunavukkarasu
- Division of Microbiology, Office of Regulatory Science, Center for Food Safety and Applied Nutrition, U.S. Food and Drug Administration, College Park, MD, United States
| | - Eric Johnson
- Department of Bacteriology, University of Wisconsin-Madison, Madison, WI, United States
| | - Segaran Pillai
- U.S. Food and Drug Administration Office of Laboratory Science and Safety, Silver Spring, MD, United States
| | - David Hodge
- Chemical and Biological Defense Division, Science and Technology Directorate, U.S. Department of Homeland Security, Washington, DC, United States
| | - Larry Stanker
- U.S. Department of Agriculture, Agriculture Research Service Albany, Albany, CA, United States
| | - Travis Wentz
- Division of Microbiology, Office of Regulatory Science, Center for Food Safety and Applied Nutrition, U.S. Food and Drug Administration, College Park, MD, United States
| | - BalRam Singh
- Institute of Advanced Sciences, Botulinum Research Center, Dartmouth, MA, United States
| | | | - Patrick McNutt
- United States Army Medical Research Institute of Chemical Defense, Aberdeen, MD, United States
| | - Michael Adler
- United States Army Medical Research Institute of Chemical Defense, Aberdeen, MD, United States
| | - Eric Brown
- Division of Microbiology, Office of Regulatory Science, Center for Food Safety and Applied Nutrition, U.S. Food and Drug Administration, College Park, MD, United States
| | - Thomas Hammack
- Division of Microbiology, Office of Regulatory Science, Center for Food Safety and Applied Nutrition, U.S. Food and Drug Administration, College Park, MD, United States
| | - Donald Burr
- Office of Regulatory Affairs, Center for Food Safety and Applied Nutrition, U.S. Food and Drug Administration, Silver Spring, MD, United States
| | - Shashi Sharma
- Division of Microbiology, Office of Regulatory Science, Center for Food Safety and Applied Nutrition, U.S. Food and Drug Administration, College Park, MD, United States
| |
Collapse
|
13
|
Weng X, Neethirajan S. Ensuring food safety: Quality monitoring using microfluidics. Trends Food Sci Technol 2017. [DOI: 10.1016/j.tifs.2017.04.015] [Citation(s) in RCA: 102] [Impact Index Per Article: 14.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|