1
|
Koosha N, Riazi MS, Janfaza P, Mohammadbeigy I, Rahimi A, Khoshali M, Pourazizi M, Peyman A. Laser vision correction after radial keratotomy: systematic review and meta-analysis. J Cataract Refract Surg 2024; 50:767-776. [PMID: 38353281 DOI: 10.1097/j.jcrs.0000000000001426] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Accepted: 02/09/2024] [Indexed: 06/25/2024]
Abstract
Laser vision correction for residual refractive errors in patients with previous radial keratotomy (RK) presents a challenging task. Different techniques have been used with varying outcomes. This study aimed to systematically review published articles on refractive surgeries in post-RK patients by conducting a search on PubMed, Scopus, and Web of Science. The final analysis included 35 studies that described a total of 888 eyes. Our systematic review and meta-analysis demonstrated a significant improvement in uncorrected distance visual acuity (UDVA) for photorefractive keratectomy (PRK), topography-guided PRK, wavefront-guided PRK, and femtosecond laser-assisted in situ keratomileusis (LASIK) while mechanical microkeratome LASIK did not yield such significant improvements. Moreover, our results suggest that post-RK patients with hyperopia had a significant improvement in UDVA, whereas no such improvement was observed in patients with myopia.
Collapse
Affiliation(s)
- Nima Koosha
- From the Isfahan Eye Research Center, Department of Ophthalmology, Isfahan University of Medical Sciences, Isfahan, Iran (Koosha, Riazi, Janfaza, Mohammadbeigy, Pourazizi, Peyman); Health Information Technology Research Center, Isfahan University Medical Sciences, Isfahan, Iran (Rahimi); Child Growth and Development Research Center, Research Institute for Primordial Prevention of Non-communicable Disease, Isfahan University of Medical Sciences, Isfahan, Iran (Khoshali)
| | | | | | | | | | | | | | | |
Collapse
|
2
|
Kanclerz P, Bazylczyk N, Przewłócka K, Khoramnia R, Atchison DA, Tuuminen R. Risk Factors for Corneal Monochromatic Aberrations and Implications for Multifocal and Extended Depth-of-Focus Intraocular Lens Implantation. J Refract Surg 2024; 40:e420-e434. [PMID: 38848055 DOI: 10.3928/1081597x-20240416-01] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/13/2024]
Abstract
PURPOSE To discuss factors influencing corneal aberrations that might influence the optical quality after intraocular lens (IOL) implantation. METHODS PubMed and Scopus were the main resources used to search the medical literature. An extensive search was performed to identify relevant articles concerning factors influencing the level of corneal aberrations as of August 27, 2023. The following keywords were used in various combinations: corneal, aberrations, defocus, astigmatism, spherical aberration, coma, trefoil, quadrafoil, intraocular lens, and IOL. RESULTS Conclusive evidence is lacking regarding the correlation between age and changes in corneal aberrations. Patients with astigmatism have greater corneal higher-order aberrations than those with minimal astigmatism, particularly concerning trefoil and coma. Increased levels of corneal higher-order aberrations are noted following contact lens wear, in patients with dry eye disease, and with pterygium. Increased higher-order aberrations have been reported following corneal refractive surgery and for 3 months following trabeculectomy; regarding intraocular lens surgery, the results remain controversial. CONCLUSIONS Several factors influence the level of corneal higher-order aberrations. Multifocal and extended depth-of-focus IOLs can share similarities in their optical properties, and the main difference arises in their design and performance with respect to spherical aberration. Preoperative evaluation is critical for proper IOL choice, particularly in corneas with risk of high levels of aberrations. [J Refract Surg. 2024;40(6):e420-e434.].
Collapse
|
3
|
Yan S, Song X, Hu X, Yao K, Qu S. A novel intraocular pressure predicting method based on hyperelastic mechanical model of cornea. J Mech Behav Biomed Mater 2024; 153:106475. [PMID: 38430796 DOI: 10.1016/j.jmbbm.2024.106475] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2023] [Revised: 02/15/2024] [Accepted: 02/24/2024] [Indexed: 03/05/2024]
Abstract
Measuring intraocular pressure (IOP) is crucial and remains challenging in diagnosing glaucoma, as it is associated with cornea deformation during inflation. In this study, a three-dimensional analytical model based on hyperelastic constitutive relationship to predict correlation between cornea vertex displacement and the IOP is proposed. The analytical model is validated by rigorous experiments. Rabbit corneas were selected for this study and their mechanical properties were obtained using uniaxial tensile tests. To mimic the environment in which the cornea exists, an artificial anterior chamber equipped with water-injection pipelines was constructed to study the relationship between the corneal vertex displacement with IOP value in practical situation. The experimental results of rabbits corneas prove that the IOP can be deduced based on the measured corneal vertex displacement by the analytical model. Furthermore, subtle difference occurs when comparing the calculated human IOPs with those measured by medical equipment, demonstrating that the proposed method is suitable for monitoring the IOP of human. This novel IOP predicting method provides new inspiration for the design of eyepieces, as well as the preoperative preparation for laser surgery and evaluation of corneal damage.
Collapse
Affiliation(s)
- Shi Yan
- Eye Center, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, 310009, PR China; State Key Laboratory of Fluid Power & Mechatronic System, Key Laboratory of Soft Machines and Smart Devices of Zhejiang Province, and Department of Engineering Mechanics, Zhejiang University, Hangzhou, 310027, PR China
| | - Xiaohui Song
- Eye Center, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, 310009, PR China
| | - Xiaocheng Hu
- State Key Laboratory of Fluid Power & Mechatronic System, Key Laboratory of Soft Machines and Smart Devices of Zhejiang Province, and Department of Engineering Mechanics, Zhejiang University, Hangzhou, 310027, PR China; China Academy of Space Technology (Xi'an), Xi'an, 710100, PR China.
| | - Ke Yao
- Eye Center, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, 310009, PR China.
| | - Shaoxing Qu
- Eye Center, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, 310009, PR China; State Key Laboratory of Fluid Power & Mechatronic System, Key Laboratory of Soft Machines and Smart Devices of Zhejiang Province, and Department of Engineering Mechanics, Zhejiang University, Hangzhou, 310027, PR China.
| |
Collapse
|
4
|
Cañones-Zafra R, Gros-Otero J, Garcia-Gonzalez M, Casado S, Ketabi S, Villa-Collar C, Teus MA. Atomic force microscopy for the evaluation of corneal surface roughness after femtosecond laser flap creation and excimer ablation. Int Ophthalmol 2023; 43:4131-4136. [PMID: 37505289 DOI: 10.1007/s10792-023-02821-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Accepted: 07/10/2023] [Indexed: 07/29/2023]
Abstract
INTRODUCTION It is well known that the femtosecond laser lamellar cut induces some degree of surface roughness. Nevertheless, as in femtosecond laser-assisted LASIK (FS-LASIK), an excimer LASIK ablation is performed, and the post-ablation stromal bed should show some degree of smoothening. We decided to compare, using atomic force microscopy (AFM), the roughness of the corneal stromal bed, after a femtosecond lasers device flap was created with or without an excimer myopic ablation. METHODS Using 6 freshly enucleated porcine eyes, we created in every eye a flap using a femtosecond laser. Additionally, in 3 eyes, an excimer laser ablation to correct-3 diopters (D) was made. AFM imaging of the remaining corneal stroma was performed. Ten different square areas of 20 μm x 20 μm at the central area of the stroma of each corneal sample were studied. The roughness parameters used were the root-mean-square deviation from a perfectly flat surface. RESULTS The RMS deviation was 360 ± 120 nm in femtosecond laser only, and 110 ± 20 nm in those cases where excimer is also involved (p < 0.0001). CONCLUSIONS Our results show that the roughness of the surface treated with excimer is clearly lower than in the group with no excimer ablation; thus, the application of laser excimer after a flap created by femtosecond laser seems to soften the nano-irregularities created by this technique.
Collapse
Affiliation(s)
- Rafael Cañones-Zafra
- Department of Ophthalmology, Hospital Universitario Príncipe de Asturias, Carretera Alcalá-Meco S/N, 28805, Alcalá de Henares, Madrid, Spain.
- Clínica Novovisión, Madrid, Spain.
| | | | | | | | - Samira Ketabi
- Department of Ophthalmology, Hospital Universitario Príncipe de Asturias, Carretera Alcalá-Meco S/N, 28805, Alcalá de Henares, Madrid, Spain
| | - César Villa-Collar
- Clínica Novovisión, Madrid, Spain
- Department of Pharmacy, Biotechnology, Nutrition, Optics and Optometry, Universidad Europea de, Madrid, Spain
| | - Miguel A Teus
- Department of Ophthalmology, Hospital Universitario Príncipe de Asturias, Carretera Alcalá-Meco S/N, 28805, Alcalá de Henares, Madrid, Spain
- Clínica Novovisión, Madrid, Spain
| |
Collapse
|
5
|
Moshirfar M, Santos JM, Wang Q, Stoakes IM, Porter KB, Theis JS, Hoopes PC. A Literature Review of the Incidence, Management, and Prognosis of Corneal Epithelial-Related Complications After Laser-Assisted In Situ Keratomileusis (LASIK), Photorefractive Keratectomy (PRK), and Small Incision Lenticule Extraction (SMILE). Cureus 2023; 15:e43926. [PMID: 37614825 PMCID: PMC10443604 DOI: 10.7759/cureus.43926] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/22/2023] [Indexed: 08/25/2023] Open
Abstract
Our purpose is to provide a comprehensive investigation into the incidence, treatment modalities, and visual prognosis of epithelial-related complications in corneal refractive surgeries, including laser-assisted in situ keratomileusis (LASIK), photorefractive keratectomy (PRK), and small incision lenticule extraction (SMILE). A systematic search of multiple databases was conducted by two independent examiners using various search terms related to epithelial-related complications and corneal refractive surgeries. A total of 91 research articles were included, encompassing a sample size of 66,751 eyes across the three types of surgeries. The average incidence of epithelial-related complications varied across the different types of corneal refractive surgeries. LASIK had an average incidence of 4.9% for epithelial defects, while PRK and SMILE had lower rates of 3.3% and 3.9%, respectively. Our findings indicate that SMILE has a lower incidence of epithelial defects compared to LASIK, potentially due to the less invasive nature of lenticule incision in SMILE. Visual prognosis after epithelial complications (EC) is generally favorable, with various supportive care and surgical interventions leading to significant improvements in postoperative visual acuity and full recovery. Understanding the incidence rates and management approaches for epithelial-related complications can guide clinicians in enhancing patient safety, refining surgical techniques, and optimizing postoperative outcomes in corneal refractive surgeries.
Collapse
Affiliation(s)
- Majid Moshirfar
- Corneal and Refractive Surgery, Hoopes Vision Research Center, Draper, USA
- Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, USA
- Eye Banking and Corneal Transplantation, Utah Lions Eye Bank, Murray, USA
| | - Jordan M Santos
- Medicine, University of Arizona College of Medicine, Phoenix, USA
| | | | - Isabella M Stoakes
- Osteopathic Medicine, Pacific Northwest University of Health Sciences, Yakima, USA
| | - Kaiden B Porter
- Medicine, University of Arizona College of Medicine, Phoenix, USA
| | - Josh S Theis
- Medicine, University of Arizona College of Medicine, Phoenix, USA
| | | |
Collapse
|
6
|
Mandal S, Namdev V, Sen S, Sinha R. Bilateral post-LASIK exacerbation of granular corneal dystrophy with epithelial ingrowth. BMJ Case Rep 2023; 16:e254328. [PMID: 37316286 PMCID: PMC10277075 DOI: 10.1136/bcr-2022-254328] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/16/2023] Open
Abstract
A male patient in his 30s, with a history of bilateral microkeratome-assisted myopic laser-assisted in situ keratomileusis (LASIK) 8 years ago at another centre, presented to us with gradually progressive diminution of vision and glare in both eyes for the last 4 years. On presentation, uncorrected distance visual acuity (UDVA) was 6/24 and 6/15 in the right eye and left eye, respectively, with normal intraocular pressures. Slit-lamp examination and anterior segment optical coherence tomography revealed well-defined white deposits, limited to an area within the LASIK flap. The deposits were confluent, at the level of the LASIK flap interface, and few discrete opacities were present in the posterior stroma. His father also had a similar clinical picture in both eyes. A diagnosis of both eyes post-LASIK exacerbation of granular corneal dystrophy with epithelial ingrowth was made. He underwent right eye femtosecond laser-assisted sutureless superficial anterior lamellar keratoplasty. At 6-month follow-up, UDVA improved to 6/12 with graft clarity of 4+ and coexistent grade 1 epithelial ingrowth.
Collapse
Affiliation(s)
- Sohini Mandal
- Ophthalmology, All India Institute of Medical Sciences, New Delhi, Delhi, India
| | - Vaibhav Namdev
- Ophthalmology, All India Institute of Medical Sciences, New Delhi, Delhi, India
| | - Seema Sen
- Ocular Pathology, All India Institute of Medical Sciences, New Delhi, Delhi, India
| | - Rajesh Sinha
- Ophthalmology, All India Institute of Medical Sciences, New Delhi, Delhi, India
| |
Collapse
|
7
|
Tian H, Gao W, Xu C, Wang Y. Clinical outcomes and higher order aberrations of wavefront-guided LASIK versus SMILE for correction of myopia: A systemic review and meta-analysis. Acta Ophthalmol 2023. [PMID: 36726315 DOI: 10.1111/aos.15638] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Revised: 11/27/2022] [Accepted: 01/08/2023] [Indexed: 02/03/2023]
Abstract
To systematically evaluate the clinical effect of wavefront-guided laser in situ keratomileusis (WFG-LASIK) and small incision lenticule extraction (SMILE) in terms of refractive errors and high-order aberrations. A systematic literature search of PubMed, EMBASE, the Cochrane Library, Web of Science and China National Knowledge Internet was performed to identify studies evaluating the clinical outcomes of SMILE and WFG-LASIK ended in May 2022. Meta-analyses were performed according to the PRISMA guidelines. The risk of bias of the RCTs was evaluated using the Cochrane Handbook criteria, and the quality of the non-randomised controlled studies was assessed using the Newcastle-Ottawa Scale. In total, 1385 eyes (SMILE group, 750 eyes; WFG-LASIK group, 635 eyes) from 12 studies were included. The meta-analysis demonstrated that spherical aberration was smaller in the SMILE group than in the WFG-LASIK group (standardised mean difference [SMD]: -0.34, 95% confidence interval [CI]: -0.47, -0.22; p < 0.00001), and that the postoperative values of vertical coma (SMD: 0.83; 95% CI: 0.63, 1.03; p < 0.00001) and trefoil (SMD: 0.37; 95% CI: 0.02, 0.72; p = 0.04) were higher in the SMILE group compared to the WFG LASIK group. There were no significant differences in the clinical outcomes and the values of induced total higher order aberrations between the WFG-LASIK and SMILE groups (SMD: 0.05; 95% CI: -0.09, 0.19; p = 0.47). Both SMILE and WFG-LASIK were found to be safe, effective, and predictable. SMILE may induce more vertical coma and trefoil, whereas WFG LASIK may induce more spherical aberrations, but no significant differences were found in the total higher order aberrations between SMILE and WFG-LASIK.
Collapse
Affiliation(s)
- He Tian
- School of Medicine, Nankai University, Tianjin, China.,Nankai University Eye Institute, Nankai University Affiliated Eye Hospital, Nankai University, Tianjin, China.,Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Tianjin Eye Hospital, Tianjin, China
| | - Wenjing Gao
- Nankai University Eye Institute, Nankai University Affiliated Eye Hospital, Nankai University, Tianjin, China.,Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Tianjin Eye Hospital, Tianjin, China.,Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China
| | - Caohui Xu
- School of Medicine, Nankai University, Tianjin, China.,Nankai University Eye Institute, Nankai University Affiliated Eye Hospital, Nankai University, Tianjin, China.,Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Tianjin Eye Hospital, Tianjin, China
| | - Yan Wang
- Nankai University Eye Institute, Nankai University Affiliated Eye Hospital, Nankai University, Tianjin, China.,Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Tianjin Eye Hospital, Tianjin, China.,Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China
| |
Collapse
|
8
|
Peñarrocha‐Oltra S, Soto‐Peñaloza R, Alonso‐Arroyo A, Vidal‐Infer A, Pascual‐Segarra J. Laser-based refractive surgery techniques to treat myopia in adults. An overview of systematic reviews and meta-analyses. Acta Ophthalmol 2022; 100:878-893. [PMID: 35535010 PMCID: PMC9790262 DOI: 10.1111/aos.15160] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2021] [Revised: 03/22/2022] [Accepted: 04/18/2022] [Indexed: 12/30/2022]
Abstract
Systematic reviews (SRs) and meta-analyses (MAs) are of great importance for basing clinical decisions. However, misleading interpretations may result when informed decisions rest on biased review papers with methodological issues. To evaluate which treatment is optimal, an overview was made of SRs and MAs to establish the quality and certainty of meta-evidence published on the efficacy of laser-based refractive surgery techniques for treating myopia in adults. A search was made in five databases and was updated using Really Simple Syndication (RSS) feed appliances up to April 2021; SRs with or without MAs were included. Methodological quality was appraised using the AMSTAR-2 tool. The best available reviews were summarized using the GRADE approach. The corrected covered area (CCA) was used to determine the degree of over-representation of publications. The risk of bias of the primary studies was disclosed visually. Thirty-six studies published between 2003 and 2021 were included. Twenty SRs (56%) were conducted in China. The most studied comparisons were SMILE versus FS-LASIK (19%) and FS-LASIK versus MM-LASIK (11%). Of the 251 overlapping index publications, 165 were unique (CCA = 0.015%), representing a negligible risk of skewed reporting. The AMSTAR-2 tool showed most SRs to have critically low or low quality. Nine reviews presented moderate quality. The GRADE approach of the 41 a priori outcomes evidenced critically low and low certainty of evidence. Only the spherical equivalent refraction changes at 12 months between LASEK and PRK showed moderate certainty of evidence, favouring PRK (mean difference 0.06, 95%CI [-0.02 to 0.14], I2 = 0%; p ≥ 0.05). Index trials among less biased reviews are prone to selection, performance and reporting bias. The appraised techniques exhibit comparable results in terms of efficacy. There is moderate certainty of evidence in favour of the use of PRK over LASEK in terms of the spherical equivalent refraction error changes at 1 year of follow-up. Most appraised SRs presented methodological flaws in critical domains, resulting in a low to critically low certainty of evidence after GRADE appraisal. Therefore, investigators need to study and compare the different laser-based refractive techniques to provide better evidence-based medicine. Further well-designed, high-quality clinical trials and SRs are needed to reappraise the current findings.
Collapse
Affiliation(s)
- Sonia Peñarrocha‐Oltra
- Hospital Lluís AlcanyísXàtivaSpain,Faculty of Medicine and DentistryUniversity of ValenciaValenciaSpain
| | | | - Adolfo Alonso‐Arroyo
- UISYS. Department of History of Science and Information ScienceSchool of Medicine and Dentistry, University of ValenciaValenciaSpain
| | - Antonio Vidal‐Infer
- UISYS. Department of History of Science and Information ScienceSchool of Medicine and Dentistry, University of ValenciaValenciaSpain
| | | |
Collapse
|
9
|
Vieira R, Marta A, Abreu AC, Monteiro S, Brochado MDC. Quality of Vision After LASIK, PRK and FemtoLASIK: An Analysis Using the Double Pass Imaging System HD AnalyzerTM ®. Clin Ophthalmol 2022; 16:3351-3359. [PMID: 36237491 PMCID: PMC9553308 DOI: 10.2147/opth.s373448] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2022] [Accepted: 07/13/2022] [Indexed: 11/06/2022] Open
Abstract
Purpose Analyze and compare the quality of vision of Photorefractive keratectomy (PRK), LASER in situ keratomileusis with mechanical microkeratome (LASIK) and femtosecond-assisted LASIK (FS-LASIK) using the double-pass imaging system HD AnalyzerTM®. Setting Ophthalmology department of Centro Hospitalar Universitário do Porto (CHUPorto). Design Retrospective, non-randomized, single center study. Methods Analysis of three equivalent groups of patients submitted to PRK, LASIK and FS-LASIK at our department. The objective quality of vision assessment included the objective scatter index (OSI), the modular transfer function cutoff frequency (MTF) and the predicted visual acuity within the 100% (PVA), 20% (PVA20) and 9% contrast levels (PVA9) that were evaluated at baseline, 1st week, 1 and 6 months after surgery. Results 118 eyes were included: 40 underwent LASIK, 43 FS-LASIK and 35 PRK. The mean age was 30.6±4.6 years old and 56% were female. There was a significant impact concerning the type of procedure in the objective quality of vision analysis (Repeated measures ANOVA): the FS-LASIK group showed lower OSI values overtime [F(1,2)=4.566, p=0.012, OSI 0.83±0.53 (FS-LASIK) vs 0.87±0.47 (PRK) and 1.21±1.44 (LASIK)], higher MTF values [F(1,2)=6.569, p=0.002, MTF 40.17±8.33 vs 32.37±11.4 (PRK) and 30.26±10.28 (LASIK)], higher PVA 100% [F(1,2)=10.871, p<0.001], PVA 20% [F(1,2)=9.737, p<0.001] and PVA 9% [F(1,2)=6.335), p=0.003]. Conclusion In our study, FS-LASIK showed an excellent optical performance through the HD AnalyzerTM technology, with significantly lower OSI and higher MTF, PVA100, PVA20 and PVA9 values. According to our results, this procedure seems to be superior to PRK and LASIK regarding visual quality objective parameters.
Collapse
Affiliation(s)
- Rita Vieira
- Refractive Surgery Unit of Ophthalmology Department of Centro Hospitalar Universitário do Porto (CHUPorto), Oporto, Portugal,Correspondence: Rita Vieira, Tel +351 913748812, Email
| | - Ana Marta
- Refractive Surgery Unit of Ophthalmology Department of Centro Hospitalar Universitário do Porto (CHUPorto), Oporto, Portugal
| | - Ana Carolina Abreu
- Refractive Surgery Unit of Ophthalmology Department of Centro Hospitalar Universitário do Porto (CHUPorto), Oporto, Portugal
| | - Sílvia Monteiro
- Refractive Surgery Unit of Ophthalmology Department of Centro Hospitalar Universitário do Porto (CHUPorto), Oporto, Portugal
| | - Maria do Céu Brochado
- Refractive Surgery Unit of Ophthalmology Department of Centro Hospitalar Universitário do Porto (CHUPorto), Oporto, Portugal
| |
Collapse
|
10
|
Yan Q, Han B, Ma ZC. Femtosecond Laser-Assisted Ophthalmic Surgery: From Laser Fundamentals to Clinical Applications. MICROMACHINES 2022; 13:1653. [PMID: 36296006 PMCID: PMC9611681 DOI: 10.3390/mi13101653] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Revised: 09/19/2022] [Accepted: 09/28/2022] [Indexed: 06/16/2023]
Abstract
Femtosecond laser (FSL) technology has created an evolution in ophthalmic surgery in the last few decades. With the advantage of high precision, accuracy, and safety, FSLs have helped surgeons overcome surgical limits in refractive surgery, corneal surgery, and cataract surgery. They also open new avenues in ophthalmic areas that are not yet explored. This review focuses on the fundamentals of FSLs, the advantages in interaction between FSLs and tissues, and typical clinical applications of FSLs in ophthalmology. With the rapid progress that has been made in the state of the art research on FSL technologies, their applications in ophthalmic surgery may soon undergo a booming development.
Collapse
Affiliation(s)
- Quan Yan
- Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200080, China
- National Clinical Research Center for Eye Diseases, Shanghai 200080, China
- Shanghai Engineering Center for Visual Science and Photomedicine, Shanghai 200080, China
| | - Bing Han
- Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Zhuo-Chen Ma
- Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai 200240, China
| |
Collapse
|
11
|
Pluma-Jaramago I, Rocha-de-Lossada C, Rachwani-Anil R, Sánchez-González JM. Small-aperture intracorneal inlay implantation in emmetropic presbyopic patients: a systematic review. Eye (Lond) 2022; 36:1747-1753. [PMID: 35347289 PMCID: PMC9391325 DOI: 10.1038/s41433-022-02032-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2020] [Revised: 01/22/2022] [Accepted: 03/14/2022] [Indexed: 11/09/2022] Open
Abstract
Small-aperture corneal inlays, commonly known as KAMRA, are tiny optical devices inserted in the corneal stroma aiming to gain near vision in patients with presbyopia. The purpose of this study was to systematically review case series of small-aperture corneal inlays performed in presbyopic emmetropic patients and to evaluate the visual outcomes of this procedure. This systematic review included 18 articles published between 2011 and 2018, overall studying 2724 eyes from 2691 participants. The mean longest follow-up was 19 months. Results showed that 78.5% of eyes reported an uncorrected near visual acuity of 20/32 or better and 90.50% of eyes achieved an uncorrected distance visual acuity of 20/25 or better. All patients experienced an improvement in uncorrected near visual acuity with a patient satisfaction ranging between 60% and 90%. The highlighted complications were keratocyte activation leading to corneal stromal haze, epithelial growth, iron deposits and poor distance visual acuity. Explantation was carried out in 101 eyes (3.7%) due to distance vision blurriness, development of epithelial microcysts, incorrect implant placement or hyperopic shift changes. KAMRA demonstrated high efficacy. However, safety and satisfaction rates remain unclear. Despite the low explantation rates reported in the literature, some complications were permanent. The results and conclusions should be taken with caution due to the conflict of interest stated in the reviewed articles.
Collapse
Affiliation(s)
- Inés Pluma-Jaramago
- Department of Physics of Condensed Matter., Optics Area, University of Seville, Seville, Spain
| | - Carlos Rocha-de-Lossada
- Department of Ophthalmology, Hospital Universitario Virgen de las Nieves, Granada, Spain
- Department of Ophthalmology, Ceuta Medical Center, Ceuta, Spain
- Department of Ophthalmology (Qvision), Vithas Almería, Almería, Spain
| | | | | |
Collapse
|
12
|
Smadja D, Mimouni M, Shoshani A, Kaiserman I, Lavy I, Santhiago MR. Accuracy of the Preoperative Predicted Percentage of Tissue Altered Calculation in Refractive Surgery Planning for Myopic LASIK. J Refract Surg 2022; 38:422-427. [PMID: 35858196 DOI: 10.3928/1081597x-20220602-02] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To determine the reliability of the percentage of tissue altered (PTA) calculation as part of the planning strategy for myopic laser in situ keratomileusis (LASIK) by comparing the estimated PTA provided by preoperative calculation to the postoperative PTA actually achieved in microkeratome-assisted myopic LASIK. METHODS This retrospective study included 3,624 eyes of 3,624 patients who underwent mechanical microkeratome-assisted LASIK surgery for myopic correction. The calculated preoperative PTA values based on the planned flap thickness and ablation depth were compared with the actual achieved postoperative PTA using the difference of corneal central thickness postoperatively for assessing the achieved ablation depth and the intraoperative ultrasound-assisted flap thickness measurement. Regression analysis was performed to reveal preoperative parameters that might influence PTA calculation accuracy. RESULTS The mean difference between the estimated and achieved PTA was 0.451 ± 3.45% (P < .001) (95% CI: 0.3708 to 0.5322) with a preoperative and postoperative mean PTA of 31.07 ± 4.07% and 31.52 ± 5.78%, respectively. The differences between the achieved and planned maximum ablation depth and flap thickness were 4.32 ± 13.70 µm (P < .001) and -1.61 ± 13.66 µm (P < .001), respectively. CONCLUSIONS Although a statistically significant difference was found between the preoperative calculated PTA and actually achieved PTA, the difference in PTA value (less than 1%) was clinically non-significant and indicated a highly reliable metric for preoperative refractive surgery planning. [J Refract Surg. 2022;38(7):422-427.].
Collapse
|
13
|
Gros-Otero J, Rodríguez-Pérez I, Teus MA, Katsanos A, Mikropoulos DG, García-González M. Myopic LASIK Outcomes: Comparison of Three Different Femtosecond Lasers and a Mechanical Microkeratome Using the Same Excimer Laser. Ophthalmol Ther 2022; 11:1047-1066. [PMID: 35262896 PMCID: PMC9114235 DOI: 10.1007/s40123-022-00486-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Accepted: 02/11/2022] [Indexed: 10/28/2022] Open
Abstract
INTRODUCTION To compare the influence of one microkeratome and three femtosecond lasers on myopic laser in situ keratomileusis (LASIK) outcomes. METHODS Retrospective, observational cohort study. We compared 134 eyes treated with the IntraLase 60 kHz, 112 eyes treated with the Femto LDV Z6, 206 eyes treated with the FS200, and 98 eyes treated with the Hansatome zero compression microkeratome. All eyes were operated on using the same surgical protocol with the same excimer laser (Wavelight Allegretto) and were allocated to refraction-matched groups. RESULTS One day and one week postoperatively, uncorrected distance visual acuity was significantly lower in the FS200 group compared to others (P = 0.0001). This difference disappeared at the 1- and 3-month postoperative visits. Significant differences were found among groups in terms of safety index (P = 0.0001), residual sphere (P = 0.0001), and residual cylinder (P = 0.02) at the 3-month postoperative visit. No significant differences were found in corrected distance visual acuity or efficacy index. CONCLUSION According to our results, a slight delay in visual restoration after FS200 LASIK surgery might be expected. This delay was statistically significant at 1 day and 1 week postoperatively, but there were no differences from the 1-month visit onwards. Additionally, significant differences were found among devices in terms of safety index and the refractive results, which were found not to be clinically relevant.
Collapse
Affiliation(s)
| | | | - Miguel A Teus
- Clínica Novovisión, Paseo de la Castellana 54, 28046, Madrid, Spain.,Hospital Universitario "Príncipe de Asturias", University of Alcalá, Alcalá de Henares, Madrid, Spain
| | - Andreas Katsanos
- Department of Ophthalmology, University of Ioannina, Ioannina, Greece
| | - Dimitrios G Mikropoulos
- 3rd University Department of Ophthalmology, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | | |
Collapse
|
14
|
Kloft LJ, Hill JE, Leang RS, Gwon AE, Huang LC. Preclinical Safety and Efficacy Assessments for Novel Femtosecond Lasers in Corneal Refractive Surgery. Ophthalmol Ther 2022; 11:521-532. [PMID: 35122607 PMCID: PMC8927562 DOI: 10.1007/s40123-022-00465-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2021] [Accepted: 01/11/2022] [Indexed: 11/24/2022] Open
Abstract
Preclinical safety requirements and test methods have been standardized over time to guide medical device developers in the path needed to manufacture safe devices and achieve regulatory approval. Today, femtosecond lasers are commonly used in cataract and refractive surgeries. Currently, an industry standard to guide developers in preclinical testing of ophthalmic lasers does not exist. Consequently, the data presented in regulatory submissions may vary between manufacturers, making the regulatory review process more ambiguous. Here, the authors present a comprehensive discussion of preclinical test methods applied to the evaluation of an ophthalmic laser. We include in vitro and ex vivo models, as well as an in vivo rabbit model subject to corneal refractive treatments, for consideration in a preclinical safety evaluation plan. Scientific rationale to support the ocular endpoints of evaluation in the rabbit model to demonstrate safety is also presented and discussed.
Collapse
Affiliation(s)
- Lisa J Kloft
- Research & Development, Johnson & Johnson Surgical Vision, Inc., 1700 East Saint Andrew Place, Santa Ana, CA, 92705, USA
| | - James E Hill
- Research & Development, Johnson & Johnson Surgical Vision, Inc., 1700 East Saint Andrew Place, Santa Ana, CA, 92705, USA
| | - Ronika S Leang
- Research & Development, Johnson & Johnson Surgical Vision, Inc., 1700 East Saint Andrew Place, Santa Ana, CA, 92705, USA
| | - Arlene E Gwon
- Gavin Herbert Eye Institute, University of California, Irvine, Irvine, CA, USA
| | - Ling C Huang
- Research & Development, Johnson & Johnson Surgical Vision, Inc., 1700 East Saint Andrew Place, Santa Ana, CA, 92705, USA.
| |
Collapse
|
15
|
KARADAĞ MF. Comparison of visual and refractive outcomes between femtosecond laser-assisted in situ keratomileusis (FS-LASIK) and photorefractive keratectomy (PRK): a long-term outcomes analysis. JOURNAL OF HEALTH SCIENCES AND MEDICINE 2022. [DOI: 10.32322/jhsm.1011444] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
|
16
|
Menon J. Refractive Corneal surgeries: A Review. KERALA JOURNAL OF OPHTHALMOLOGY 2022. [DOI: 10.4103/kjo.kjo_21_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
17
|
Özbilen KT, Altinkurt E, Ceylan NA, Bilgin GS, Gözüm N. Effect of Myopic Femtosecond Laser-Assisted LASIK on Anterior Chamber Inflammation (Flare Values) and Corneal Endothelium: A Prospective before and after Study. J Ophthalmol 2021; 2021:2395028. [PMID: 34868671 PMCID: PMC8642012 DOI: 10.1155/2021/2395028] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Revised: 11/03/2021] [Accepted: 11/09/2021] [Indexed: 11/29/2022] Open
Abstract
PURPOSE This study aimed to investigate whether femtosecond laser-assisted LASIK (FS-LASIK) surgery causes inflammation in the anterior chamber and to analyze its effect on endothelial cells. METHODS This prospective, longitudinal study included left eyes of 30 patients (19 females) who had undergone FS-LASIK surgery due to myopia and myopic astigmatism. Endothelial cell density (ECD) and morphological measurements were performed using a specular microscopy, and laser flare photometry was used to measure the anterior chamber flare values on the day of surgery. iFS™ Advanced FS and VISX STAR S4-IR Wavescan Excimer Laser platforms were used. Flare measurements were repeated on the postoperative 1st day and 7th day and the 1st and 3rd months. The endothelial measurements were repeated in the 3rd month. RESULTS Preoperatively, the mean flare was 5.59 ± 1.24 photons/ms; it was 6.49 ± 2.42 on the postoperative 1st day, 5.87 ± 2.27 on the 7th day, 5.68 ± 1.66 on the 1st month, and 5.35 ± 1.24 on the 3rd month. A significant difference was observed only between the preoperative and postoperative 1st day flare values (p=0.047). The decrease in the ECD was clinically insignificant but statistically significant, with an average of 97.0 ± 209.9 cell count/mm2 (3.3%, p=0.017). However, there was no significant change in the coefficient of variation (p=0.448) and hexagonality (p=0.096). No significant correlation was found between the increase in the flare value on the postoperative 1st day and variables. A significant correlation was found between the decrease in ECD and the preoperative ECD (r = 0.356, p=0.027). CONCLUSION FS-LASIK caused minimal inflammation in the anterior chamber on only the 1st postoperative day; additionally, a minimal decrease of cell count with no morphological changes were noted in the endothelial cells on postoperative 3rd month. This trial is registered with NCT04899258.
Collapse
Affiliation(s)
- Kemal Turgay Özbilen
- Istanbul University, Istanbul Faculty of Medicine, Department of Ophthalmology, Istanbul, Turkey
| | - Emre Altinkurt
- Istanbul University, Istanbul Faculty of Medicine, Department of Ophthalmology, Istanbul, Turkey
| | - Nihan Aksu Ceylan
- Istanbul University, Istanbul Faculty of Medicine, Department of Ophthalmology, Istanbul, Turkey
| | - Gizem Sayar Bilgin
- Istanbul University, Istanbul Faculty of Medicine, Department of Ophthalmology, Istanbul, Turkey
| | - Nilüfer Gözüm
- Istanbul University, Istanbul Faculty of Medicine, Department of Ophthalmology, Istanbul, Turkey
| |
Collapse
|
18
|
Sánchez-González JM, Borroni D, Rachwani-Anil R, Rocha-de-Lossada C. Refractive corneal inlay implantation outcomes: a preliminary systematic review. Int Ophthalmol 2021; 42:713-722. [PMID: 34599717 DOI: 10.1007/s10792-021-02024-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2020] [Accepted: 09/22/2021] [Indexed: 11/26/2022]
Abstract
PURPOSE To review all case series of refractive corneal inlay implantation: Flexivue (Presbia, Netherlands), Invue (BioVision, Brügg, Switzerland) and Icolens (Neoptics, Hünenberg, Switzerland) performed in presbyopia patients and to evaluate the reported visual outcomes. In addition, our aim is to provide assessment for complications and to report the satisfaction rates. METHODS PubMed, Web of Science and Scopus databases were consulted using "refractive corneal inlay", "Flexivue Inlay", "Invue Inlay" and "Icolens inlay" as keywords. 147 articles were found, and they were assessed considering the inclusion and exclusion criteria. After filtering, this systemic review included ten articles, published between 2011 and 2020. RESULTS 308 eyes from 308 participants were enrolled in this systematic review. Mean maximum follow-up was 13.9 months. Nine of the ten case series included used femtosecond laser for the corneal pocket creation. Mean pocket depth was 293.75 µm. 77.5% of the eyes reported a postoperative uncorrected near visual acuity of 20/32 or better, and 19.20% of the inlay-implanted eyes achieved an uncorrected distance visual acuity of 20/20 or better. The most prominent complications were halos, pain, photophobia, and poor distance visual acuity. 27 eyes (8.7%) had to be explanted due to complications, such as near-distance spectacle dependence or blurred distance vision. CONCLUSION Refractive corneal inlay outcomes demonstrated high efficacy, safety, and satisfaction rates. Furthermore, it is a reversible technique. However, the findings must be viewed with caution due potential conflict of interest. Further research with higher sample size is needed to validate these findings.
Collapse
Affiliation(s)
- José-María Sánchez-González
- Department of Physics of Condensed Matter, Optics Area, University of Seville, Reina Mercedes St., Seville, Spain.
- Department of Ophthalmology and Optometry, Tecnolaser Clinic Vision, Seville, Spain.
| | - Davide Borroni
- Department of Ophthalmology, Fondazione Banca Degli Occhi Del Veneto Onlus, Zelarino, Venezia, Italy
- Department of Doctoral Studies, Riga Stradins University, Riga, Latvia
| | - Rahul Rachwani-Anil
- Department of Ophthalmology, Hospital Regional Universitario de Málaga, Málaga, Spain
| | - Carlos Rocha-de-Lossada
- Department of Ophthalmology, Hospital Virgen de la Nieves, Granada, Spain
- Department of Ophthalmology (Qvision), Vithas Virgen del Mar Hospital, Almería, Spain
| |
Collapse
|
19
|
Flap Thickness and the Risk of Complications in Mechanical Microkeratome and Femtosecond Laser In Situ Keratomileusis: A Literature Review and Statistical Analysis. Diagnostics (Basel) 2021; 11:diagnostics11091588. [PMID: 34573930 PMCID: PMC8468565 DOI: 10.3390/diagnostics11091588] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2021] [Revised: 08/11/2021] [Accepted: 08/17/2021] [Indexed: 11/16/2022] Open
Abstract
INTRODUCTION A recent Cochrane review found no difference in visual acuity outcomes between femtosecond-assisted laser in situ keratomileusis (LASIK) and LASIK using mechanical microkeratomes (MMKs). This study compares the flap thickness and risk of complications related to flap creation using femtosecond lasers and MMKs. METHODS PubMed and the Web of Science are used to search the medical literature. An extensive search is performed to identify the flap thickness and complications of LASIK as reported up to 15 July 2021. The following keywords are used in various combinations: Corneal flap, femtosecond laser, laser in situ keratomileusis, laser-assisted in situ keratomileusis, LASIK, mechanical microkeratome. RESULTS After removing duplicates and irrelevant studies, 122 articles were included for review. Pooled differences for intended vs. postoperative flap thickness using MMKs and femtosecond laser were -4.07 μm (95% CI: -19.55, 3.24 μm) in studies on the MMK and 5.43 μm (95% CI: 2.30, 7.84 μm; p < 0.001), respectively. After removing the studies evaluating outcomes of the old generation Hansatome MMKs (which had a significantly greater variation of flap thickness), the pooled difference for newer MMKs was 4.97 μm (95% CI: 0.35, 9.58 μm; p < 0.001), but the results still favored the femtosecond laser. Uncommon and mild complications unique for the femtosecond LASIK are epithelial gas breakthrough, opaque bubble layer, transient light sensitivity syndrome, and rainbow glare. A single study reported a very low, but stastically different risk of postoperative flap slippage (0.033% for MMK LASIK, and 0.003% for femtosecond LASIK, respectively). CONCLUSION In both manual microkeratome and femtosecond LASIK, intra- and postoperative complications were uncommon. The evidence of the superiority of one technique in terms of complications over another cannot be indisputably stated.
Collapse
|
20
|
Comparison of the optical quality after SMILE and FS-LASIK for high myopia by OQAS and iTrace analyzer: a one-year retrospective study. BMC Ophthalmol 2021; 21:292. [PMID: 34340669 PMCID: PMC8330115 DOI: 10.1186/s12886-021-02048-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2021] [Accepted: 07/09/2021] [Indexed: 01/02/2023] Open
Abstract
BACKGROUND To compare the correction effect and optical quality after small-incision lenticule extraction (SMILE) and femtosecond laser assisted laser in situ keratomileusis (FS-LASIK) for high myopia. METHODS 51 high myopia eyes after SMILE and 49 high myopia eyes after FS-LASIK were enrolled and divided into two groups retrospectively. The OQAS and iTrace analyzer were used for optical quality inspection. Between the two groups the spherical equivalent (SE), astigmatism, uncorrected distant visual acuity (UDVA), strehl ratio (SR), modulation transfer function cutoff frequency (MTF cutoff), objective scatter index (OSI) and wavefront aberrations were analyzed and compared before surgery and at 1, 6 and 12 months after surgery. RESULTS After the operation: (1) SE and astigmatism declined and UDVA increased significantly in both groups, and UDVA was better after SMILE than FS-LASIK. (2) SR and MTF cutoff reduced and OSI increased significantly after SMILE and FS-LASIK. SR and MTF cutoff were significantly higher after SMILE than FS-LASIK. OSI was significantly lower after SMILE than FS-LASIK. (3) The total wavefront aberration, total low-order wavefront aberration, defocus and astigmatism aberration as well as trefoil aberration reduced significantly in both groups. The total high-order wavefront aberration increased significantly after FS-LASIK. The spherical and coma aberration increased significantly in both groups. The total high-order wavefront aberration and coma aberration at 1 month were higher after FS-LASIK than SMILE. CONCLUSION The optical quality descended after SMILE and FS-LASIK. SMILE was superior to FS-LASIK at the correction effect and optical quality for high myopia. The combination of OQAS and iTrace analyzer is a valuable complementary measurement in evaluating the optical quality after the refractive surgery. TRIAL REGISTRATION This is a retrospective study. This research was approved by the ethics committee of Xiangya Hospital and the IRB approval number is 201612074.
Collapse
|
21
|
Das S, Garg P, Mullick R, Annavajjhala S. Keratitis following laser refractive surgery: Clinical spectrum, prevention and management. Indian J Ophthalmol 2021; 68:2813-2818. [PMID: 33229656 PMCID: PMC7856934 DOI: 10.4103/ijo.ijo_2479_20] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Laser refractive surgery (LRS) is one of the most demanding areas of ophthalmic surgery and high level of precision is required to meet outcome expectations of patients. Post-operative recovery is of vital importance. Keratitis occurring after LRS can delay visual recovery. Both surface ablations [Photorefractive keratectomy (PRK)] as well as flap procedures [Laser in-situ keratomileusis (LASIK)/Small incision lenticule extraction] are prone to this complication. Reported incidence of post-LRS infectious keratitis is between 0% and 1.5%. The rate of infections after PRK seems to be higher than that after LASIK. Staphylococci, streptococci, and mycobacteria are the common etiological organisms. About 50–60% of patients present within the first week of surgery. Of the non-infectious keratitis, diffuse lamellar keratitis (DLK) is the most common with reported rates between 0.4% and 4.38%. The incidence of DLK seems to be higher with femtosecond LASIK than with microkeratome LASIK. A lot of stress is laid on prevention of this complication through proper case selection, asepsis, and use of improved protocols. Once keratitis develops, the right approach can help resolve this condition quickly. In cases of suspected microbial keratitis, laboratory identification of the organism is important. Most lesions resolve with medical management alone. Interface irrigation, flap amputation, collagen cross-linking and therapeutic penetrating keratoplasty (TPK) are reserved for severe/non-resolving cases. About 50–75% of all infectious keratitis cases post LRS resolve with a final vision of 20/40 or greater. Improved awareness, early diagnosis, and appropriate intervention can help limit the damage to cornea and preserve vision.
Collapse
Affiliation(s)
- Shilpa Das
- Cornea and Refractive Services, Narayana Nethralaya Eye Hospital, Bengaluru, Karnataka, India
| | - Prashant Garg
- Paul Dubord Chair of Cornea, L.V Prasad Eye Institute, Hyderabad, Telangana, India
| | - Ritika Mullick
- Cornea and Refractive Services, Narayana Nethralaya Eye Hospital, Bengaluru, Karnataka, India
| | - Sriram Annavajjhala
- Cornea and Refractive Services, Narayana Nethralaya Eye Hospital, Bengaluru, Karnataka, India
| |
Collapse
|
22
|
Femtosecond-Laser Assisted Surgery of the Eye: Overview and Impact of the Low-Energy Concept. MICROMACHINES 2021; 12:mi12020122. [PMID: 33498878 PMCID: PMC7912418 DOI: 10.3390/mi12020122] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/15/2020] [Revised: 01/13/2021] [Accepted: 01/18/2021] [Indexed: 11/16/2022]
Abstract
This article provides an overview of both established and innovative applications of femtosecond (fs)-laser-assisted surgical techniques in ophthalmology. Fs-laser technology is unique because it allows cutting tissue at very high precision inside the eye. Fs lasers are mainly used for surgery of the human cornea and lens. New areas of application in ophthalmology are on the horizon. The latest improvement is the high pulse frequency, low-energy concept; by enlarging the numerical aperture of the focusing optics, the pulse energy threshold for optical breakdown decreases, and cutting with practically no side effects is enabled.
Collapse
|
23
|
Niparugs M, Supalaset S, Tangmonkongvoragul C, Tananuvat N, Chaidaroon W, Ausayakhun S. Incidence and predisposing factors of anterior chamber gas bubbles during femtosecond laser flap creation. Int J Ophthalmol 2020; 13:1334-1337. [PMID: 32821690 PMCID: PMC7387908 DOI: 10.18240/ijo.2020.08.22] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2019] [Accepted: 02/12/2020] [Indexed: 11/23/2022] Open
Abstract
AIM To investigate the incidence and the predisposing factors of anterior chamber (AC) gas bubbles during femtosecond laser (FS) flap creation for laser in situ keratomileusis (LASIK). METHODS All patients who underwent FS-LASIK surgery at CMU LASIK Center between January 2013 and May 2016 were retrospective reviewed. Preoperative and intraoperative data including keratometry, white-to-white (WTW) corneal diameter, flap parameters (diameter, thickness, hinge position, and tunnel length) and pulse energy were reviewed and compared between incident group and control group. To determine the risk factors, univariate and multivariate conditional logistic regression were used; the eye was unit of analysis. RESULTS The incidence of AC gas bubbles was 1.6% (22 out of 1378 eyes). The median WTW in the AC bubbles group was 11.5 mm (range 11.1-12.1), which was significantly different from the control group (11.7 mm, range 10.5-12.8, P=0.021). The result of the median WTW minus the flap diameter in the AC bubbles group was 2.5 mm (range 2.1-3.2), which was statistically different to the control group (2.7 mm, range 1.5-3.8, P=0.008). The logistic regression analysis showed that the result of the WTW minus the flap diameter in the AC bubbles group had an adjusted odds ratio of 0.204 (95%CI; 0.056-0.747, P=0.016). CONCLUSION Development of AC gas bubbles during FS flap creation is not an uncommon event in Asian eyes which typically have a small WTW. The flap diameter when adjusted relatively to the WTW is a predisposing factor to the possibility of AC gas bubbles occurrence.
Collapse
Affiliation(s)
- Muanploy Niparugs
- Chiang Mai University LASIK Center, Center of Medical Excellence; Department of Ophthalmology, Faculty of Medicine, Chiang Mai University, Chiang Mai 50200, Thailand
| | - Sumet Supalaset
- Chiang Mai University LASIK Center, Center of Medical Excellence; Department of Ophthalmology, Faculty of Medicine, Chiang Mai University, Chiang Mai 50200, Thailand
| | - Chulaluck Tangmonkongvoragul
- Chiang Mai University LASIK Center, Center of Medical Excellence; Department of Ophthalmology, Faculty of Medicine, Chiang Mai University, Chiang Mai 50200, Thailand
| | - Napaporn Tananuvat
- Chiang Mai University LASIK Center, Center of Medical Excellence; Department of Ophthalmology, Faculty of Medicine, Chiang Mai University, Chiang Mai 50200, Thailand
| | - Winai Chaidaroon
- Chiang Mai University LASIK Center, Center of Medical Excellence; Department of Ophthalmology, Faculty of Medicine, Chiang Mai University, Chiang Mai 50200, Thailand
| | - Somsanguan Ausayakhun
- Chiang Mai University LASIK Center, Center of Medical Excellence; Department of Ophthalmology, Faculty of Medicine, Chiang Mai University, Chiang Mai 50200, Thailand
| |
Collapse
|
24
|
Gulmez M, Tekce A, Kamıs U. Comparison of refractive outcomes and high-order aberrations after small incision lenticule extraction and wavefront-guided femtosecond-assisted laser in situ keratomileusis for correcting high myopia and myopic astigmatism. Int Ophthalmol 2020; 40:3481-3489. [PMID: 32737727 DOI: 10.1007/s10792-020-01534-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2020] [Accepted: 07/25/2020] [Indexed: 10/23/2022]
Abstract
PURPOSE To compare the results of using small incision lenticule extraction (SMILE) and wavefront-guided femtosecond-assisted laser in situ keratomileusis (WFG FS-LASIK) to correct high myopia and myopic astigmatism. MATERIAL AND METHODS The 94 eyes of 47 patients with high myopia or myopic astigmatism, if not both, who had undergone SMILE were compared with the 94 eyes of 47 patients with high myopia or myopic astigmatism, also if not both, who had undergone WFG FS-LASIK. Only eyes with high myopic or myopic astigmatism errors greater than - 6.0 diopter (D) spherical refraction and 0-3 D cylindrical refraction were included. Values of uncorrected distance visual acuity, corrected distance visual acuity, efficacy index, safety index, predictability, and high-order aberration between the patient groups were compared. RESULTS The SMILE and WFG FS-LASIK groups did not significantly differ according to sex or age. Values of preoperative and postoperative spherical refraction, cylindrical refraction, spherical equivalent, uncorrected distance visual acuity, and corrected distance visual acuity between the groups also did not significantly differ nor did values of predictability, the efficacy index, or the safety index. SMILE induced more coma and trefoil (p < 0.001), whereas WFG FS-LASIK induced more spherical aberration (p < 0.001). CONCLUSION Both SMILE and WFG FS-LASIK are efficient, safe, predictable procedures for correcting high myopia and myopic astigmatism. SMILE may induce more coma and trefoil, whereas WFG FS-LASIK may induce more spherical aberration.
Collapse
Affiliation(s)
- Mehmet Gulmez
- Department of Ophthalmology, The Dunya Goz Eye Hospital, Konya, Turkey.
| | - Abdulhakim Tekce
- Department of Ophthalmology, The Dunya Goz Eye Hospital, Baku, Azerbaijan
| | - Umit Kamıs
- Department of Ophthalmology, The Dunya Goz Eye Hospital, Konya, Turkey
| |
Collapse
|
25
|
Abd El-Fattah EA, El Dorghamy AA, Ghoneim AM, Saad HA. Comparison of corneal biomechanical changes after LASIK and F-SMILE with CorVis ST. Eur J Ophthalmol 2020; 31:1762-1770. [PMID: 32698618 DOI: 10.1177/1120672120945664] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE To evaluate changes in corneal biomechanics after LASIK and F-SMILE. SETTING Elite Eye Center, Tanta, Egypt. DESIGN Prospective, randomized, unmasked, interventional comparative case series. PATIENTS AND METHODS A total of 60 eyes were equally divided into two groups; group A: received LASIK and group B: received F-SMILE. Pentacam and CorVis ST parameters were compared before and 6 months after procedures. P ⩽ 0.05 was used for significance of results. RESULTS bIOP decreased by 0.762 ± 1.211 mmHg in group A (p = 0.092), and by 2.52 ± 1.389 mmHg in group B (p < 0.001) and the difference between groups became significant (p = 0.001). A1 increased significantly in group A only (p = 0.036); while A2 decreased insignificantly in both groups. DAR increased significantly in both groups (p < 0.001, p = 0.022), but the difference between groups remained insignificant (p = 0.461). IR increased significantly in group A only (p < 0.001) and the difference between groups became significant (p = 0.026). ARTH decreased in both groups (p = 0.245, p = 0.695) and the difference remained insignificant (p = 0.928). SP-A1 decreased in group A by 8.89 ± 1.38 mmHg/mm (p = 0.637), and by 32.6 ± 4.39 mmHg/mm in group B (p < 0.001) and the postoperative difference between groups was significant (p = 0.013). CBI increased significantly in group A (p < 0.001), but insignificantly in group B (p = 0.098) and postoperative difference between groups was highly significant (p < 0.001). A significant correlation was found between change in CCT and corresponding changes in DAR, IR, and ARTH after surgery in both groups. CONCLUSION The significant differences between groups postoperatively as regards bIOP (p = 0.001), IR (p = 0.026), SP-A1 (p = 0.013), and CBI (p < 0.001) indicate stiffer corneas after F-SMILE and suggest less influence on corneal biomechanics than LASIK.
Collapse
Affiliation(s)
- Eman A Abd El-Fattah
- Department of Ophthalmology, Faculty of Medicine, Tanta University, Tanta, Egypt
| | - Alaa A El Dorghamy
- Department of Ophthalmology, Faculty of Medicine, Tanta University, Tanta, Egypt
| | - Ahmed M Ghoneim
- Department of Ophthalmology, Faculty of Medicine, Tanta University, Tanta, Egypt
| | - Hisham A Saad
- Department of Ophthalmology, Faculty of Medicine, Tanta University, Tanta, Egypt
| |
Collapse
|
26
|
Application of Femtosecond Laser in Anterior Segment Surgery. J Ophthalmol 2020; 2020:8263408. [PMID: 32351726 PMCID: PMC7171667 DOI: 10.1155/2020/8263408] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2020] [Accepted: 03/12/2020] [Indexed: 11/24/2022] Open
Abstract
Femtosecond laser (FSL) is a near-infrared laser that can create reliable and reproducible tissue cutting with minimal damage to adjacent tissue. As the laser can also create incisions with various orientations, depths, and shapes, it is expected to be a useful tool for anterior segment surgery, such as cornea, refractive, and cataract surgery. In this review, the authors will introduce the application of FSL in various anterior segment surgeries and discuss the results of studies regarding the efficacy and safety of FSL in cornea, refractive, and cataract surgery. Experimental studies regarding the potential use of FSL will also be introduced. The studies discussed in this review suggest that FSL may be a useful tool for improving the prognosis and safety of surgeries of the anterior segment.
Collapse
|
27
|
Kahuam-López N, Navas A, Castillo-Salgado C, Graue-Hernandez EO, Jimenez-Corona A, Ibarra A. Laser-assisted in-situ keratomileusis (LASIK) with a mechanical microkeratome compared to LASIK with a femtosecond laser for LASIK in adults with myopia or myopic astigmatism. Cochrane Database Syst Rev 2020; 4:CD012946. [PMID: 32255519 PMCID: PMC7137867 DOI: 10.1002/14651858.cd012946.pub2] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND Laser-assisted in-situ keratomileusis (LASIK) is a surgical procedure that corrects refractive errors. This technique creates a flap of the outermost parts of the cornea (epithelium, bowman layer, and anterior stroma) to expose the middle part of the cornea (stromal bed) and reshape it with excimer laser using photoablation. The flaps can be created by a mechanical microkeratome or a femtosecond laser. OBJECTIVES To compare the effectiveness and safety of mechanical microkeratome versus femtosecond laser in LASIK for adults with myopia. SEARCH METHODS We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2019, Issue 2); Ovid MEDLINE; Embase; PubMed; LILACS; ClinicalTrials.gov and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP). We used no date or language restrictions. We searched the reference lists of included trials. We searched the electronic databases on 22 February 2019. SELECTION CRITERIA We included randomized controlled trials (RCTs) of LASIK with a mechanical microkeratome compared to a femtosecond laser in people aged 18 years or older with more than 0.5 diopters of myopia or myopic astigmatism. DATA COLLECTION AND ANALYSIS We used standard methodological procedures expected by Cochrane. MAIN RESULTS We included 16 records from 11 trials enrolling 943 adults (1691 eyes) with spherical or spherocylindrical myopia, who were suitable candidates for LASIK. Five hundred and forty-seven participants (824 eyes) received LASIK with a mechanical microkeratome and 588 participants (867 eyes) with a femtosecond laser. Each trial included between nine and 360 participants. In six trials, the same participants received both interventions. Overall, the trials were at an uncertain risk of bias for most domains. At 12 months, data from one trial (42 eyes) indicates no difference in the mean uncorrected visual acuity (logMAR scale) between LASIK with a mechanical microkeratome and LASIK with a femtosecond laser (mean difference (MD) -0.01, 95% confidence interval (CI) -0.06 to 0.04; low-certainty evidence). Similar findings were observed at 12 months after surgery, regarding participants achieving 0.5 diopters within target refraction (risk ratio (RR) 0.97, 95% CI 0.85 to 1.11; 1 trial, 79 eyes; low-certainty evidence) as well as mean spherical equivalent of the refractive error 12 months after surgery (MD 0.09, 95% CI -0.01 to 0.19; 3 trials, 168 eyes [92 participants]; low-certainty evidence). Based on data from three trials (134 eyes, 66 participants), mechanical microkeratome was associated with lower risk of diffuse lamellar keratitis compared with femtosecond laser (RR 0.27, 95% CI 0.10 to 0.78; low-certainty evidence). Thus, diffuse lamellar keratitis was a more common adverse event with femtosecond laser than with mechanical microkeratome, decreasing from an assumed rate of 209 per 1000 people in the femtosecond laser group to 56 per 1000 people in the mechanical microkeratome group. Data from one trial (183 eyes, 183 participants) indicates that dry eye as an adverse event may be more common with mechanical microkeratome than with femtosecond laser, increasing from an assumed rate of 80 per 1000 people in the femtosecond laser group to 457 per 1000 people in the mechanical microkeratome group (RR 5.74, 95% CI 2.92 to 11.29; low-certainty evidence). There was no evidence of a difference between the two groups for corneal haze (RR 0.33, 95% CI 0.01 to 7.96; 1 trial, 43 eyes) and epithelial ingrowth (RR 1.04, 95% CI 0.11 to 9.42; 2 trials, 102 eyes [50 participants]). The certainty of evidence for both outcomes was very low. AUTHORS' CONCLUSIONS Regarding the visual acuity outcomes, there may be no difference between LASIK with mechanical microkeratome and LASIK with femtosecond laser. Dry eye and diffuse lamellar keratitis are likely adverse events with mechanical microkeratome and femtosecond laser, respectively. The evidence is uncertain regarding corneal haze and epithelial ingrowth as adverse events of each intervention. The limited number of outcomes reported in the included trials, some with potentially significant risk of bias, makes it difficult to draw a firm conclusion regarding the effectiveness and safety of the interventions investigated in this review.
Collapse
Affiliation(s)
- Nicolás Kahuam-López
- Universidad Anáhuac México, Campus Norte, Centro de Investigación en Ciencias de la Salud (CICSA), Facultad de Ciencias de la Salud, Av. Universidad Anáhuac 46, Huixquilucan, Mexico, Mexico, 52786
- Instituto de Oftalmología Fundación Conde de Valenciana, Cornea and Refractive Surgery Department, Chimalpopoca 14, Mexico City, Mexico City, Mexico, 06800
| | - Alejandro Navas
- Instituto de Oftalmología Fundación Conde de Valenciana, Cornea and Refractive Surgery Department, Chimalpopoca 14, Mexico City, Mexico City, Mexico, 06800
| | - Carlos Castillo-Salgado
- Johns Hopkins Bloomberg School of Public Health, Department of Epidemiology, 615 N. Wolfe Street, Room E-6136, Baltimore, Maryland, USA, 21205
| | - Enrique O Graue-Hernandez
- Instituto de Oftalmología Fundación Conde de Valenciana, Cornea and Refractive Surgery Department, Chimalpopoca 14, Mexico City, Mexico City, Mexico, 06800
| | - Aida Jimenez-Corona
- Instituto de Oftalmología Fundación Conde de Valenciana, Ocular Epidemiology and Visual Sciences Department, Chimalpopoca 14 Col Obrera del Cuauhtemoc, Mexico City, Mexico, 06800
| | - Antonio Ibarra
- Universidad Anáhuac México, Campus Norte, Centro de Investigación en Ciencias de la Salud (CICSA), Facultad de Ciencias de la Salud, Av. Universidad Anáhuac 46, Huixquilucan, Mexico, Mexico, 52786
| |
Collapse
|
28
|
Zhang Y, Lan J, Cao D, Yang C, Yang D, Xie W, Zeng J. Microvascular changes in macula and optic nerve head after femtosecond laser-assisted LASIK: an optical coherence tomography angiography study. BMC Ophthalmol 2020; 20:107. [PMID: 32183742 PMCID: PMC7079532 DOI: 10.1186/s12886-020-01368-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2019] [Accepted: 03/04/2020] [Indexed: 11/13/2022] Open
Abstract
Background To measure the microcirculation change of macula and optic nerve head before and after femtosecond laser assisted laser in situ keratomileusis. Methods In total 45 eyes from 45 subjects, who underwent FS-LASIK during June 2017 to December 2017 in Guangdong Provincial People’s Hospital, were recruited in this study. Vessel density in macula and optic nerve head were measured by optical coherence tomography angiography before and after transient elevation in intraocular pressure caused by application of suction ring during surgery. Results Vessel density (VD) at superficial (SCP) plexus of macular region did not differ after surgery (F(3,132) = 1.41, P = 0.24), while the deep (DCP) plexus of macular region significantly decreased 1 day after surgery (P = 0.001) but returned to its baseline value 1 month postoperatively (P = 0.1). Vessel density of optic nerve head region had no significant changes after surgery (F(2.51,95.18) = 0.6, P = 0.59). Conclusions A short-term temporary decrease of vessel density at deep layer of macular region was observed in eyes undergoing FS-LASIK. However, the retinal capillary density went back to preoperative level 1 month after surgery. Therefore, transient IOP spike during FS-LASIK did not cause long-term decline of retinal microcirculation.
Collapse
Affiliation(s)
- Yan Zhang
- Department of Ophthalmology, Guangdong Eye Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, No. 106 Zhongshan Er Road, Guangzhou, 510080, China
| | - Jianqing Lan
- Department of Ophthalmology, Guangdong Eye Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, No. 106 Zhongshan Er Road, Guangzhou, 510080, China
| | - Dan Cao
- Department of Ophthalmology, Guangdong Eye Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, No. 106 Zhongshan Er Road, Guangzhou, 510080, China
| | - Cheng Yang
- Department of Ophthalmology, Guangdong Eye Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, No. 106 Zhongshan Er Road, Guangzhou, 510080, China
| | - Dawei Yang
- Department of Ophthalmology, Guangdong Eye Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, No. 106 Zhongshan Er Road, Guangzhou, 510080, China
| | - Wenjuan Xie
- Department of Ophthalmology, Guangdong Eye Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, No. 106 Zhongshan Er Road, Guangzhou, 510080, China
| | - Jin Zeng
- Department of Ophthalmology, Guangdong Eye Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, No. 106 Zhongshan Er Road, Guangzhou, 510080, China.
| |
Collapse
|
29
|
Biscevic A, Bohac M, Pjano MA, Grisevic S, Patel S, Pidro A. Treatment of High Astigmatism with WaveLight Allegretto Eye-Q Excimer Laser Platform. Acta Inform Med 2019; 27:177-180. [PMID: 31762574 PMCID: PMC6853724 DOI: 10.5455/aim.2019.27.177-180] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022] Open
Abstract
Introduction The WaveLight Allegretto Eye-Q is a flying-spot excimer laser, with a pulse repetition rate of 400Hz, with two galvanometric scanners for positioning laser pulses. The system has an infrared high speed camera operating at 400Hz to track the patient's eye movements that either compensates for changes in eye position or interrupts the treatment if the eye moves outside a preset predetermined range. Aim The purpose of this study was to investigate WaveLight Allegretto Eye-Q 400Hz laser delivery platform aimed to correct astigmatism by subjecting the pre and postoperative astigmatic values to vector analysis. Methods Patients were divided into two groups, depending on the type of astigmatism. Astigmatism was between 2 and 7 diopters (D). A total of 188 eyes (110 patients), 127 eyes (71 patients) with myopic astigmatism and 61 eyes (39 patients) with mixed astigmatism underwent unremarkable LASIK correction on WaveLight Allegretto Eye-Q 400Hz. The preoperative and postoperative sphere, negative cylinder [C] and axis (ø) of manifest refractions were subjected to vector analysis by calculations of the standard J0 (cos [4π(ø-90)/360]xC/2) and J45 (sin[4π(ø-90)/ 360]xC/2). Results Reporting the key results, we found that J0 significantly reduced after LASIK (p<0.001) but not J45. There was no significant association between individual pairs of pre and postoperative J0 &J45 values. Conclusion WaveLight Allegretto 400Hz showed excellent results for treating patients with high astigmatism, regardless whether it is mixed or myopic astigmatism. The J45 did not reduce significantly possibly because of the low number of eyes with oblique astigmatism. There was no genuine difference postoperatively between groups treated on WaveLight Allegretto platform according to the vector analyses.
Collapse
Affiliation(s)
- Alma Biscevic
- Eye Clinic Svjetlost Sarajevo, Sarajevo, Bosnia and Herzegovina.,University Eye Clinic Svjetlost Zagreb, Zagreb, Croatia
| | - Maja Bohac
- University Eye Clinic Svjetlost Zagreb, Zagreb, Croatia
| | | | - Senad Grisevic
- Eye Clinic Svjetlost Sarajevo, Sarajevo, Bosnia and Herzegovina
| | - Sudi Patel
- NHS National Services Scotland, Edinburgh, United Kingdom
| | - Ajla Pidro
- Eye Clinic Svjetlost Sarajevo, Sarajevo, Bosnia and Herzegovina
| |
Collapse
|
30
|
LASIK und Femto-LASIK 2019: eine Standortbestimmung. SPEKTRUM DER AUGENHEILKUNDE 2019. [DOI: 10.1007/s00717-019-00437-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
31
|
Outcomes of Flap Lift Laser In Situ Keratomileusis Enhancements in a Large Patient Population: Does Application of a Bandage Contact Lens Affect Incidence of Epithelial Ingrowth? Cornea 2019; 38:1531-1535. [DOI: 10.1097/ico.0000000000002132] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
32
|
Lau YTY, Shih KC, Tse RHK, Chan TCY, Jhanji V. Comparison of Visual, Refractive and Ocular Surface Outcomes Between Small Incision Lenticule Extraction and Laser-Assisted In Situ Keratomileusis for Myopia and Myopic Astigmatism. Ophthalmol Ther 2019; 8:373-386. [PMID: 31325106 PMCID: PMC6692806 DOI: 10.1007/s40123-019-0202-x] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2019] [Indexed: 12/12/2022] Open
Abstract
Laser-assisted in situ keratomileusis (LASIK) is the most commonly performed laser refractive surgical technique worldwide for the treatment of myopia and myopic astigmatism. In recent years, small incision lenticule extraction (SMILE) has emerged as a promising alternative to LASIK, requiring only a single femtosecond laser to create an intrastromal lenticule, which is then removed via a small incision. The technique obviates the need for a corneal flap. A number of published studies have compared the two techniques in terms of visual, refractive and ocular surface outcomes. This review compares the clinical outcomes between LASIK and SMILE in treating myopia and myopic astigmatism based on studies published in the last 5 years. Twenty-two studies were included, all of which were observational in nature. Results suggest that the two techniques have comparable visual outcomes in terms of safety, efficacy and predictability, although recovery in visual acuity may be slower in SMILE-treated than LASIK-treated eyes. SMILE is found to result in less severe postoperative dry eye symptoms and faster recovery of corneal sensitivity than LASIK. It is important to note, however, that the SMILE technique is limited by the lack of a cyclotorsion-compensation system and option for customized treatment profile. The heterogeneity of results in this review may be attributable to the use of different LASIK platforms in different studies. Few studies compared the outcomes regarding severity of myopia. Future prospective randomized controlled trials with a larger sample size and longer follow-up period will be highly beneficial for progress in this field.
Collapse
Affiliation(s)
- Yumi Tsz-Ying Lau
- Department of Ophthalmology, Li Ka Shing Faculty of Medicine, University of Hong Kong, Hong Kong SAR, China
| | - Kendrick Co Shih
- Department of Ophthalmology, Li Ka Shing Faculty of Medicine, University of Hong Kong, Hong Kong SAR, China.
| | - Ryan Hin-Kai Tse
- Department of Ophthalmology, Li Ka Shing Faculty of Medicine, University of Hong Kong, Hong Kong SAR, China
| | - Tommy Chung-Yan Chan
- Department of Ophthalmology, Hong Kong Sanatorium and Hospital, Hong Kong SAR, China
- Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Hong Kong SAR, China
| | - Vishal Jhanji
- Department of Ophthalmology, University of Pittsburgh Medical Center, Pittsburgh, USA
| |
Collapse
|
33
|
Chiam NP, Mehta JS. Comparing Patient-Reported Outcomes of Laser In Situ Keratomileusis and Small-Incision Lenticule Extraction: A Review. Asia Pac J Ophthalmol (Phila) 2019; 8:377-384. [PMID: 31478935 PMCID: PMC6784778 DOI: 10.1097/apo.0000000000000258] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2019] [Accepted: 07/30/2019] [Indexed: 11/26/2022] Open
Abstract
PURPOSE Laser in situ keratomileusis (LASIK) and small-incision lenticule extraction (SMILE) are popular refractive surgeries. The objective refractive outcomes of LASIK and SMILE have been studied extensively; both procedures have comparable safety, efficacy, and predictability. However, owing to various psychosocial factors, refractive patients may report dissatisfaction despite good postoperative vision. Hence the importance of studies on subjective patient-reported outcomes. This review discusses the role of psychometric-technique-based validated questionnaires when evaluating subjective outcomes. It also summarizes the literature on patient-reported outcomes for LASIK and SMILE. DESIGN A literature search was performed on PubMed database to identify studies that have assessed patient-reported outcomes for LASIK and SMILE. RESULTS Several studies have looked into patient-reported outcome measures for LASIK, but the number of equivalent studies for SMILE is limited. Questionnaires (validated and non-validated) are used to evaluate patient-reported outcomes. Validated questionnaires are designed based on psychometric techniques, such as Classic Test Theory, Item Response Theory, and Rasch analysis. The Quality of Life Impact of Refractive Correction (QIRC) questionnaire, a validated questionnaire administered to both LASIK and SMILE patients, suggests that both groups have comparable vision-related quality of life in the first few months postoperatively; but SMILE might confer a slight advantage in the later postoperative period (postoperative month 6). CONCLUSIONS Future LASIK-SMILE comparative studies utilizing standardized validated questionnaires for patient-reported outcome measures with longer follow-up durations would be a welcome contribution to this important aspect of refractive surgery.
Collapse
Affiliation(s)
| | - Jodhbir S. Mehta
- Singapore National Eye Centre, Singapore
- Singapore Eye Research Institute, Singapore
| |
Collapse
|
34
|
Changes in corneal biomechanics during small-incision lenticule extraction (SMILE) and femtosecond-assisted laser in situ keratomileusis (FS-LASIK). Lasers Med Sci 2019; 35:599-609. [DOI: 10.1007/s10103-019-02854-w] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2019] [Accepted: 07/26/2019] [Indexed: 10/26/2022]
|
35
|
Taha S, Azzam S, Anis M, Zaazou C, Hosny M. Verification and measurement of the side-cut angle of corneal flap in patients undergoing LASIK surgery using FS 200 kHz femtosecond laser system versus conventional mechanical microkeratome. Clin Ophthalmol 2019; 13:985-992. [PMID: 31354232 PMCID: PMC6572716 DOI: 10.2147/opth.s201150] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2019] [Accepted: 04/08/2019] [Indexed: 11/24/2022] Open
Abstract
Introduction: This is a prospective nonrandomized interventional clinical trial conducted to measure and verify the intended versus the achieved LASIK flap side-cut angle in two groups of patients, Femtosecond laser-assisted in-situ keratomileusis (FS-LASIK) using Wavelight FS200 (Alcon Laboratories Inc. Fort Worth, TX, USA) and the conventional mechanical microkeratme (Moria M2 90). Methods: This prospective clinical trial was conducted on 40 eyes of 20 patients (20 eyes in each group) in the interval between December 2017 and August 2018. Heidelberg anterior segment OCT was done for the patients 2 weeks postoperatively to measure the corneal flap side cut angle. Results: The achieved side-cut angles of all the patients in the first group (the femtosecond laser-assisted in-situ keratomileusis group) were equal to or more inverted than the intended angle (110–115°) in all the study candidates with a minimum angle (110°) and maximum angle (155°). Unlike the achieved side-cut angle in the second group (the mechanical microkeratome group) in which all the achieved side-cut angle were acute with a minimum angle (30°) and maximum angle (65°) which is more acute than the intended side-cut angle (70°). Conclusion: In our study we found that the femtoLASIK technology was capable of making the flap side-cut angle more obtuse than the intended angle, unlike the achieved flap side-cut angle done using the mechanical microkeratome which was more acute than the intended angle in 100% of cases.
Collapse
Affiliation(s)
- Sarah Taha
- Department of Ophthalmology, Cairo University Hospital, Cairo, Egypt
| | - Sarah Azzam
- Department of Ophthalmology, Cairo University Hospital, Cairo, Egypt
| | - Mohamed Anis
- Department of Ophthalmology, Cairo University Hospital, Cairo, Egypt
| | - Cherif Zaazou
- Department of Ophthalmology, Cairo University Hospital, Cairo, Egypt
| | - Mohamed Hosny
- Department of Ophthalmology, Cairo University Hospital, Cairo, Egypt
| |
Collapse
|
36
|
Garcia-Gonzalez M, Gros-Otero J, Rodriguez-Perez I, Rodero A, Teus MA. Effect of age on visual and refractive results after LASIK: mechanical microkeratome versus femtosecond laser. Int J Ophthalmol 2019; 12:488-495. [PMID: 30918820 DOI: 10.18240/ijo.2019.03.21] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2018] [Accepted: 08/06/2018] [Indexed: 11/23/2022] Open
Abstract
AIM To evaluate the effect of age on visual and refractive results after laser in situ keratomileusis (LASIK) obtained with a mechanical microkeratome or a femtosecond laser. METHODS Retrospective, nonrandomized, cohort study. A total of 3826 eyes were included in the study (1725 eyes treated with mechanical LASIK and 2101 eyes treated with femtosecond LASIK). The relationship between patient age and the 3-month postoperative visual and refractive results of both procedures were analyzed by linear regression analysis. RESULTS Three months postoperatively, we found a significant correlation between age and the postoperative spherical equivalent (SE; r 2=0.004, P=0.006), efficacy (r 2=0.006, P=0.001), and safety indexes (r 2=0.05, P=0.0001) in the mechanical LASIK group. On the other hand, we found a significant correlation between age and the postoperative SE (r 2=0.02, P=0.0001) and the efficacy index (r 2=0.01, P=0.0001) but not the safety index in the femtosecond laser group. Mechanical LASIK provided slightly but significantly better efficacy and predictability in patients 18 to 40 years of age and femtosecond LASIK did so in patients older than 40 years of age. The femtosecond laser provided better safety results than the mechanical microkeratome in both age groups. CONCLUSION A tendency toward undercorrection and less predictability is found with aging after myopic LASIK regardless of whether the flap was created with a mechanical microkeratome or a femtosecond laser. However, femtosecond laser provides significantly better outcomes in terms of efficacy, safety and predictability compared to mechanical microkeratome for the correction of myopia in patients over 40y.
Collapse
Affiliation(s)
| | | | - Isabel Rodriguez-Perez
- Clínica Novovisión Madrid, Madrid 28046, Spain.,Universidad Europea de Madrid, Villaviciosa de Odón 28670, Madrid, Spain
| | | | - Miguel A Teus
- Clínica Novovisión Madrid, Madrid 28046, Spain.,Hospital Universitario "Príncipe de Asturias", University of Alcalá, Alcalá de Henares, Madrid 28805, Spain
| |
Collapse
|
37
|
Chua D, Htoon HM, Lim L, Chan CM, Mehta JS, Tan DTH, Rosman M. Eighteen-year prospective audit of LASIK outcomes for myopia in 53 731 eyes. Br J Ophthalmol 2018; 103:1228-1234. [PMID: 30355717 DOI: 10.1136/bjophthalmol-2018-312587] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2018] [Revised: 09/28/2018] [Accepted: 10/06/2018] [Indexed: 11/04/2022]
Abstract
BACKGROUND To assess the outcomes of laser-assisted in situ keratomileusis (LASIK) performed for the treatment of myopia in terms of safety, efficacy and predictability in an 18-year clinical audit. METHOD In this single-centre, prospective, non-randomised study, preoperative and postoperative refractions, uncorrected (UCVA), best-corrected Snellen visual acuity (BCVA) and complications of all eyes undergoing myopic LASIK were recorded. Safety, efficacy, refractive predictability, treatment trends, retreatment rates and complication rates were evaluated. RESULTS Between 1998 and 2015, 53 731 eyes of 27312 patients underwent myopic LASIK. Patients' median age was 31.6 years (mean, 32.6±7.3 years); there were 9703 males (35.5%). Patients were predominantly ethnic Chinese (87.4%). Mean follow-up time was 78±75.6 days (median, 86 days). Overall efficacy index was 0.91 with >99% of eyes achieving UCVA of ≥20/40 and >70% achieving 20/20 since 2010. 95.43% of eyes had no loss of vision postoperatively and 4.2% and 0.37% lost 1 and ≥2 lines BCVA, respectively. From 2010 the safety index has been >1.05. More than 94.0% of eyes achieved within ±1.0 D of target refraction and at least 70% achieved within ±0.50 D of target from 2010 onwards. Retreatment rate was 2.55% and after retreatment 98.4% of eyes achieved ≥20/40 UCVA and 63.5% achieved ≥20/20 UCVA. The overall complication rate is 0.98%, and since 2010, the annual complication rate has been <0.8%. CONCLUSIONS Myopic LASIK performed in Asian eyes is safe and effective with high refractive predictability in a comprehensive LASIK programme with appropriate clinical audit.
Collapse
Affiliation(s)
- Daniel Chua
- Singapore National Eye Centre, Singapore, Singapore.,Singapore Eye Research Institute, Singapore, Singapore
| | - Hla Myint Htoon
- Singapore National Eye Centre, Singapore, Singapore.,Singapore Eye Research Institute, Singapore, Singapore
| | - Li Lim
- Singapore National Eye Centre, Singapore, Singapore.,Singapore Eye Research Institute, Singapore, Singapore
| | - Cordelia Ml Chan
- Singapore National Eye Centre, Singapore, Singapore.,Singapore Eye Research Institute, Singapore, Singapore
| | - Jodhbir S Mehta
- Singapore National Eye Centre, Singapore, Singapore.,Singapore Eye Research Institute, Singapore, Singapore
| | - Donald T H Tan
- Singapore National Eye Centre, Singapore, Singapore.,Singapore Eye Research Institute, Singapore, Singapore
| | - Mohamad Rosman
- Singapore National Eye Centre, Singapore, Singapore .,Singapore Eye Research Institute, Singapore, Singapore
| |
Collapse
|
38
|
Adib-Moghaddam S, Soleyman-Jahi S, Salmanian B, Omidvari AH, Adili-Aghdam F, Noorizadeh F, Eslani M. Single-step transepithelial photorefractive keratectomy in myopia and astigmatism: 18-month follow-up. J Cataract Refract Surg 2018; 42:1570-1578. [PMID: 27956283 DOI: 10.1016/j.jcrs.2016.08.029] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2016] [Revised: 08/01/2016] [Accepted: 08/16/2016] [Indexed: 11/29/2022]
Abstract
PURPOSE To evaluate the long-term quantitative and qualitative optical outcomes of 1-step transepithelial photorefractive keratectomy (PRK) to correct myopia and astigmatism. SETTING Bina Eye Hospital, Tehran, Iran. DESIGN Prospective interventional case series. METHODS Eyes with myopia with or without astigmatism were evaluated. One-step transepithelial PRK was performed with an aberration-free aspheric optimized profile and the Amaris 500 laser. Eighteen-month follow-up results for refraction, visual acuities, vector analysis, higher-order aberrations, contrast sensitivity, postoperative pain, and haze grade were assessed. RESULTS The study enrolled 146 eyes (74 patients). At the end of follow-up, 93.84% of eyes had an uncorrected distance visual acuity of 20/20 or better and 97.94% of eyes were within ±0.5 diopter of the targeted spherical refraction. On vector analysis, the mean correction index value was close to 1 and the mean index of success and magnitude of error values were close to 0. The achieved correction vector was on an axis counterclockwise to the axis of the intended correction. Photopic and mesopic contrast sensitivities and ocular and corneal spherical, cylindrical, and corneal coma aberrations significantly improved (all P < .001). A slight amount of trefoil aberration was induced (P < .001, ocular aberration; P < .01, corneal aberration). No eye lost more than 1 line of corrected distance visual acuity. No eye had a haze grade of 2+ degrees or higher throughout the follow-up. CONCLUSIONS Eighteen-month results indicate the efficacy and safety of transepithelial PRK to correct myopia and astigmatism. It improved refraction and quality of vision. FINANCIAL DISCLOSURE None of the authors has a financial or proprietary interest in any material or method mentioned.
Collapse
Affiliation(s)
- Soheil Adib-Moghaddam
- From the Bina Eye Hospital (Adib-Moghaddam, Soleyman-Jahi, Salmanian, Omidvari, Adili-Aghdam, Noorizadeh), theTransPRK Research Center (Adib-Moghaddam, Soleyman-Jahi, Salmanian, Omidvari, Adili-Aghdam, Noorizadeh), and the Universal Council of Ophthalmology (Adib-Moghaddam, Soleyman-Jahi, Salmanian, Omidvari, Adili-Aghdam, Noorizadeh), Universal Scientific Education and Research Network, Tehran, Iran; the Department of Ophthalmology and Visual Sciences (Eslani), University of Illinois at Chicago, Chicago, Illinois, USA.
| | - Saeed Soleyman-Jahi
- From the Bina Eye Hospital (Adib-Moghaddam, Soleyman-Jahi, Salmanian, Omidvari, Adili-Aghdam, Noorizadeh), theTransPRK Research Center (Adib-Moghaddam, Soleyman-Jahi, Salmanian, Omidvari, Adili-Aghdam, Noorizadeh), and the Universal Council of Ophthalmology (Adib-Moghaddam, Soleyman-Jahi, Salmanian, Omidvari, Adili-Aghdam, Noorizadeh), Universal Scientific Education and Research Network, Tehran, Iran; the Department of Ophthalmology and Visual Sciences (Eslani), University of Illinois at Chicago, Chicago, Illinois, USA
| | - Bahram Salmanian
- From the Bina Eye Hospital (Adib-Moghaddam, Soleyman-Jahi, Salmanian, Omidvari, Adili-Aghdam, Noorizadeh), theTransPRK Research Center (Adib-Moghaddam, Soleyman-Jahi, Salmanian, Omidvari, Adili-Aghdam, Noorizadeh), and the Universal Council of Ophthalmology (Adib-Moghaddam, Soleyman-Jahi, Salmanian, Omidvari, Adili-Aghdam, Noorizadeh), Universal Scientific Education and Research Network, Tehran, Iran; the Department of Ophthalmology and Visual Sciences (Eslani), University of Illinois at Chicago, Chicago, Illinois, USA
| | - Amir-Houshang Omidvari
- From the Bina Eye Hospital (Adib-Moghaddam, Soleyman-Jahi, Salmanian, Omidvari, Adili-Aghdam, Noorizadeh), theTransPRK Research Center (Adib-Moghaddam, Soleyman-Jahi, Salmanian, Omidvari, Adili-Aghdam, Noorizadeh), and the Universal Council of Ophthalmology (Adib-Moghaddam, Soleyman-Jahi, Salmanian, Omidvari, Adili-Aghdam, Noorizadeh), Universal Scientific Education and Research Network, Tehran, Iran; the Department of Ophthalmology and Visual Sciences (Eslani), University of Illinois at Chicago, Chicago, Illinois, USA
| | - Fatemeh Adili-Aghdam
- From the Bina Eye Hospital (Adib-Moghaddam, Soleyman-Jahi, Salmanian, Omidvari, Adili-Aghdam, Noorizadeh), theTransPRK Research Center (Adib-Moghaddam, Soleyman-Jahi, Salmanian, Omidvari, Adili-Aghdam, Noorizadeh), and the Universal Council of Ophthalmology (Adib-Moghaddam, Soleyman-Jahi, Salmanian, Omidvari, Adili-Aghdam, Noorizadeh), Universal Scientific Education and Research Network, Tehran, Iran; the Department of Ophthalmology and Visual Sciences (Eslani), University of Illinois at Chicago, Chicago, Illinois, USA
| | - Farsad Noorizadeh
- From the Bina Eye Hospital (Adib-Moghaddam, Soleyman-Jahi, Salmanian, Omidvari, Adili-Aghdam, Noorizadeh), theTransPRK Research Center (Adib-Moghaddam, Soleyman-Jahi, Salmanian, Omidvari, Adili-Aghdam, Noorizadeh), and the Universal Council of Ophthalmology (Adib-Moghaddam, Soleyman-Jahi, Salmanian, Omidvari, Adili-Aghdam, Noorizadeh), Universal Scientific Education and Research Network, Tehran, Iran; the Department of Ophthalmology and Visual Sciences (Eslani), University of Illinois at Chicago, Chicago, Illinois, USA
| | - Medi Eslani
- From the Bina Eye Hospital (Adib-Moghaddam, Soleyman-Jahi, Salmanian, Omidvari, Adili-Aghdam, Noorizadeh), theTransPRK Research Center (Adib-Moghaddam, Soleyman-Jahi, Salmanian, Omidvari, Adili-Aghdam, Noorizadeh), and the Universal Council of Ophthalmology (Adib-Moghaddam, Soleyman-Jahi, Salmanian, Omidvari, Adili-Aghdam, Noorizadeh), Universal Scientific Education and Research Network, Tehran, Iran; the Department of Ophthalmology and Visual Sciences (Eslani), University of Illinois at Chicago, Chicago, Illinois, USA
| |
Collapse
|
39
|
Abstract
PURPOSE To analyze the incidence, indications, and outcomes associated with early flap relifting after uncomplicated laser in situ keratomileusis (LASIK). METHODS All LASIK cases from a single surgical center between 2007 and 2015 were reviewed. Early postoperative flap lift cases (<15 d after surgery) were identified. RESULTS Overall, 25,712 eyes were included, of which 366 (1.42%) underwent early postoperative flap lifting. There was a significant reduction in early postoperative flap lifting rates from 2006 (2.46%) to 2015 (0.92%) (P = 0.001). Reasons for early flap lifting included striae (n = 301, 1.17%), diffuse lamellar keratitis (n = 62, 0.24%), flap dislocation (n = 20, 0.08%), epithelial ingrowth (n = 18, 0.07%), and interface debris (n = 15, 0.06%). There was a significant difference in rates and outcomes of flap relifting among high-volume surgeons (P < 0.001). The flap lift group had a significantly lower final safety index (0.95 ± 0.16 vs. 1.01 ± 0.15, P < 0.001), efficacy index (0.85 ± 0.26 vs. 0.94 ± 0.26, P < 0.001), and a higher distance from target refraction (0.39 ± 0.61 vs. 0.21 ± 0.46 D). In unilateral cases, the study eye had a lower safety index (P < 0.001), efficacy index (P < 0.001), and greater distance from target refraction (P = 0.003) compared with the fellow eye. After intervention, 81.1% of cases achieved full resolution, 10.1% achieved partial resolution, 4.1% required additional flap relifting, and 4.7% were nonresolved by the end of follow-up. CONCLUSIONS The main indication for early flap relifting after LASIK was striae, and most cases achieved full resolution. Although refractive and visual outcomes are lower in this group, they are, nevertheless, satisfactory.
Collapse
|
40
|
Niparugs M, Tananuvat N, Chaidaroon W, Tangmonkongvoragul C, Ausayakhun S. Outcomes of LASIK for Myopia or Myopic Astigmatism Correction with the FS200 Femtosecond Laser and EX500 Excimer Laser Platform. Open Ophthalmol J 2018; 12:63-71. [PMID: 29872485 PMCID: PMC5960747 DOI: 10.2174/1874364101812010063] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2018] [Revised: 03/28/2018] [Accepted: 04/25/2018] [Indexed: 11/22/2022] Open
Abstract
Purpose: To evaluate the efficacy, predictability, stability and safety of laser in situ keratomileusis (LASIK) using the FS200 femtosecond laser and EX500 excimer laser platform. Methods: The outcomes of 254 eyes of 129 consecutive patients with myopia or myopic astigmatism who underwent full correction femtosecond laser-assisted LASIK at CMU LASIK Center were assessed. Pre-operative and post-operative parameters including manifest refraction, Uncorrected Distance Visual Acuity (UDVA), Best Corrected Distance Visual Acuity (BDVA), corneal topography and tomography were analyzed. The results between low to moderate myopia and high myopia were compared up to 12 months. Results: Mean pre-operative Spherical Equivalent (SE) was -5.15±2.41 Diopters (D) (range -0.50 to -11.50 D) and -0.13±0.28 D, -0.13±0.27 D, -0.13±0.28 D and -0.14±0.30 D at 1, 3, 6, and 12 months, post-operatively. At 12 months, the propor¬tion of eyes achieving UDVA ≥ 20/20 was 90.0% and ≥20/40 was 98.8%. The proportion of eyes achieving post-operative mean SE ±0.5 D, and ±1 D was 91.3%, and 98.5%. No eyes lost more than two lines of BDVA. The low to moderate myopic group had a statistically significant better UDVA at one (p=0.017) and three months (p=0.014) but no difference at six (p=0.061) and 12 months (p=0.091). The mean post-operative SE was better in low to moderate myopic group at every follow-up visit (p=0.001, 0.007, <0.001 and <0.001). Conclusion: One-year clinical results of LASIK with the FS200 femtosecond laser and EX500 excimer laser showed high efficacy, predictability, stability and safety.
Collapse
Affiliation(s)
- Muanploy Niparugs
- Chiang Mai University LASIK Center, Center for Medical Excellence, and Department of Ophthalmology, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand
| | - Napaporn Tananuvat
- Chiang Mai University LASIK Center, Center for Medical Excellence, and Department of Ophthalmology, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand
| | - Winai Chaidaroon
- Chiang Mai University LASIK Center, Center for Medical Excellence, and Department of Ophthalmology, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand
| | - Chulaluck Tangmonkongvoragul
- Chiang Mai University LASIK Center, Center for Medical Excellence, and Department of Ophthalmology, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand
| | - Somsanguan Ausayakhun
- Chiang Mai University LASIK Center, Center for Medical Excellence, and Department of Ophthalmology, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand
| |
Collapse
|
41
|
Yan MK, Chang JS, Chan TC. Refractive regression after laser in situ keratomileusis. Clin Exp Ophthalmol 2018; 46:934-944. [PMID: 29700964 DOI: 10.1111/ceo.13315] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2017] [Revised: 04/13/2018] [Accepted: 04/19/2018] [Indexed: 12/23/2022]
Abstract
Uncorrected refractive errors are a leading cause of visual impairment across the world. In today's society, laser in situ keratomileusis (LASIK) has become the most commonly performed surgical procedure to correct refractive errors. However, regression of the initially achieved refractive correction has been a widely observed phenomenon following LASIK since its inception more than two decades ago. Despite technological advances in laser refractive surgery and various proposed management strategies, post-LASIK regression is still frequently observed and has significant implications for the long-term visual performance and quality of life of patients. This review explores the mechanism of refractive regression after both myopic and hyperopic LASIK, predisposing risk factors and its clinical course. In addition, current preventative strategies and therapies are also reviewed.
Collapse
Affiliation(s)
- Mabel K Yan
- The Alfred Hospital, Melbourne, Victoria, Australia
| | - John Sm Chang
- Department of Ophthalmology, Hong Kong Sanatorium and Hospital, Hong Kong.,Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Hong Kong
| | - Tommy Cy Chan
- Department of Ophthalmology, Hong Kong Sanatorium and Hospital, Hong Kong.,Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Hong Kong
| |
Collapse
|
42
|
Williams GP, Wu B, Liu YC, Teo E, Nyein CL, Peh G, Tan DT, Mehta JS. Hyperopic refractive correction by LASIK, SMILE or lenticule reimplantation in a non-human primate model. PLoS One 2018; 13:e0194209. [PMID: 29590157 PMCID: PMC5874005 DOI: 10.1371/journal.pone.0194209] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2017] [Accepted: 02/27/2018] [Indexed: 01/23/2023] Open
Abstract
Hyperopia is a common refractive error, apparent in 25% of Europeans. Treatments include spectacles, contact lenses, laser interventions and surgery including implantable contact lenses and lens extraction. Laser treatment offers an expedient and reliable means of correcting ametropia. LASIK is well-established however SMILE (small-incision lenticule extraction) or lenticule implantation (derived from myopic laser-correction) are newer options. In this study we compared the outcomes of hyperopic LASIK, SMILE and lenticule re-implantation in a primate model at +2D/+4D treatment. While re-implantation showed the greatest regression, broadly comparable refractive results were seen at 3-months with SMILE and LASIK (<1.4D of intended), but a greater tendency to regression in +2D lenticule reimplantation. Central corneal thickness showed greater variation at +2D treatment, but central thickening during lenticule reimplantation at +4D treatment was seen (-17± 27μm LASIK, -45 ± 18μm SMILE and 28 ± 17μm Re-implantation; p <0.01) with expected paracentral thinning following SMILE. Although in vivo confocal microscopy appeared to show higher reflectivity in all +4D treatment groups, there were minimal and inconsistent changes in inflammatory responses between modalities. SMILE and lenticule re-implantation may represent a safe and viable method for treating hyperopia, but further optimization for lower hyperopic treatments is warranted.
Collapse
Affiliation(s)
- Geraint P. Williams
- Tissue Engineering and Stem Cell Group, Singapore Eye Research Institute, Singapore
- Singapore National Eye Centre, Singapore
| | - Benjamin Wu
- Ophthalmology Academic Clinical Program, Duke-NUS Graduate Medical School, Singapore
| | - Yu Chi Liu
- Tissue Engineering and Stem Cell Group, Singapore Eye Research Institute, Singapore
| | - Ericia Teo
- Tissue Engineering and Stem Cell Group, Singapore Eye Research Institute, Singapore
| | - Chan L. Nyein
- Tissue Engineering and Stem Cell Group, Singapore Eye Research Institute, Singapore
| | - Gary Peh
- Tissue Engineering and Stem Cell Group, Singapore Eye Research Institute, Singapore
| | - Donald T. Tan
- Tissue Engineering and Stem Cell Group, Singapore Eye Research Institute, Singapore
- Singapore National Eye Centre, Singapore
- Ophthalmology Academic Clinical Program, Duke-NUS Graduate Medical School, Singapore
- Department of Ophthalmology, Yong Loo Lin School of Medicine, National University of Singapore, Singapore
| | - Jodhbir S. Mehta
- Tissue Engineering and Stem Cell Group, Singapore Eye Research Institute, Singapore
- Singapore National Eye Centre, Singapore
- Ophthalmology Academic Clinical Program, Duke-NUS Graduate Medical School, Singapore
- Department of Clinical Sciences, Duke-NUS Graduate Medical School, Singapore
- * E-mail:
| |
Collapse
|
43
|
Xia LK, Ma J, Liu HN, Shi C, Huang Q. Three-year results of small incision lenticule extraction and wavefront-guided femtosecond laser-assisted laser in situ keratomileusis for correction of high myopia and myopic astigmatism. Int J Ophthalmol 2018; 11:470-477. [PMID: 29600182 DOI: 10.18240/ijo.2018.03.18] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2017] [Accepted: 11/28/2017] [Indexed: 11/23/2022] Open
Abstract
AIM To compare and calculate the 3-year refractive results, higher-order aberrations (HOAs), contrast sensitivity (CS) and dry eye parameters after small incision lenticule extraction (SMILE) and wavefront-guided femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for correction of high myopia and myopic astigmatism. METHODS In this prospective, non-randomized comparative study, 78 eyes with spherical equivalent (SE) of -8.11±1.09 diopters (D) received a SMILE surgery, and 65 eyes with SE of -8.05±1.12 D received a wavefront-guided FS-LASIK surgery with the VisuMax femtosecond laser (Carl Zeiss Meditec, Jena, Germany) for flap cutting. Visual acuity, manifest refraction, CS, HOAs, ocular surface disease index (OSDI) and tear break-up time (TBUT) were evaluated during a 3-year follow-up. RESULTS The difference of uncorrected distance visual acuity (UDVA) postoperatively was achieved at 1mo and at 3mo, whereas the difference of the mean UDVA between two groups at 3y were not statistically significant (t=-1.59, P=0.13). The postoperative change of SE was 0.89 D in the FS-LASIK group (t=5.76, P=0.00), and 0.14 D in the SMILE group (t=0.54, P=0.59) from 1mo to 3y after surgery. At 3-year postoperatively, both HOAs and spherical aberrations in the SMILE group were obviously less than those in the FS-LASIK group (P=0.00), but the coma root mean square (RMS) was higher in the SMILE group (0.59±0.26) than in the FS-LASIK group (0.29±0.14, P=0.00). The mesopic CS values between two groups were not statistically significant at 3y postoperatively. Compared with the FS-LASIK group, lower OSDI scores and longer TBUT values were found in the SMILE group at 1mo and 3mo postoperatively. With regard to safety, no eye lost any line of CDVA in both groups at 3y after surgery. CONCLUSION Both SMILE and wavefront-guided FS-LASIK procedures provide good visual outcomes. Both procedures are effective and safe, but SMILE surgery achieve more stable long-term refractive outcome and better control of early postoperative dry eye as compared to FS-LASIK.
Collapse
Affiliation(s)
- Li-Kun Xia
- Department of Ophthalmology, Shengjing Hospital, China Medical University, Shenyang 110004, Liaoning Province, China
| | - Jing Ma
- Department of Ophthalmology, the General Hospital of Shenyang Military, Shenyang 110016, Liaoning Province, China
| | - He-Nan Liu
- Department of Ophthalmology, Shengjing Hospital, China Medical University, Shenyang 110004, Liaoning Province, China
| | - Ce Shi
- Department of Ophthalmology, Shengjing Hospital, China Medical University, Shenyang 110004, Liaoning Province, China
| | - Qing Huang
- Department of Ophthalmology, Shengjing Hospital, China Medical University, Shenyang 110004, Liaoning Province, China
| |
Collapse
|
44
|
Garcia-Gonzalez M, Bouza-Miguens C, Parafita-Fernandez A, Gros-Otero J, Cañones-Zafra R, Villa-Collar C, Teus MA. Comparison of visual outcomes and flap morphology using 2 femtosecond-laser platforms. J Cataract Refract Surg 2018; 44:78-84. [DOI: 10.1016/j.jcrs.2017.10.041] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2017] [Revised: 10/18/2017] [Accepted: 10/20/2017] [Indexed: 10/17/2022]
|
45
|
Zhang J, Yu KM. Femtosecond laser corneal refractive surgery for the correction of high myopic anisometropic amblyopia in juveniles. Int J Ophthalmol 2017; 10:1678-1685. [PMID: 29181310 DOI: 10.18240/ijo.2017.11.07] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2016] [Accepted: 08/01/2017] [Indexed: 11/23/2022] Open
Abstract
AIM To evaluate the effects of femtosecond laser-assisted in situ keratomileusis (FS-LASIK) and small-incision lenticule extraction (SMILE) to correct high myopic anisometropic amblyopia in juvenile patients. METHODS From November 2013 to January 2015, 33 amblyopic patients with high myopic anisometropic amblyopia were studied. FS-LASIK (30 eyes) or SMILE (3 eyes) was performed in the amblyopic eyes. Visual acuity, refraction, contrast sensitivity, stereoacuity and complications were evaluated. Patients completed follow-up examinations at 3d, 1mo, 3mo and the last follow-up time (mean 8.17±3.23mo) after surgery. RESULTS The mean age at surgery was 9.04±3.04y (range 6-16y). The mean spherical equivalent in the amblyopic eyes was significantly decreased from -10.00±2.39 D preoperatively to -0.06±1.06 D at 1mo, -0.19±1.33 D at 3mo and -0.60±1.43 D at approximately 8mo postoperatively (P<0.05 for all). The mean myopic anisometropia was significantly decreased from -9.45±2.33 D preoperatively to +0.37±1.48 D at 1mo, -0.46±1.47 D at 3mo and -0.09±1.83 D at approximately 8mo (P<0.05 for all). The logarithm of the minimum angle of resolution (logMAR) for uncorrected and corrected distance visual acuity (UDVA and CDVA, respectively) of the amblyopic eye improved from 1.74±0.35 and 0.98±0.63 preoperatively to 0.45±0.31 and 0.41±0.33 at approximately 8mo after surgery, respectively. The logMAR CDVA at 3d, 1, 3 and 8mo postoperatively improved by means of 1.42, 2.22, 2.96, and 4.39 lines, and a gain of more than two lines accounted for 45%, 50%, 74% and 86% of all patients, respectively. The contrast sensitivity of both amblyopic eyes and dominant eyes at 0.5, 2, 8 cycles per degree was significantly improved postoperatively (P<0.05 for all). Of the 33 pediatric patients, no patients had near stereopsis preoperatively and seven patients (21.2%) recovered near stereopsis (400″ to 60″) at approximately 8mo after surgery. No intraoperative or postoperative complications occurred in any patient. CONCLUSION FS-LASIK or SMILE can be promising alternative methods to correct high myopic anisometropic amblyopia in juvenile patients who have failed with traditional approaches.
Collapse
Affiliation(s)
- Jing Zhang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou 510060, Guangdong Province, China
| | - Ke-Ming Yu
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou 510060, Guangdong Province, China
| |
Collapse
|
46
|
[LenSx® femto-LASIK, FEMTO LDV Z4® femto-LASIK, and PRK : Comparison of refractive results and an analysis of complications]. Ophthalmologe 2017; 115:928-940. [PMID: 29085999 DOI: 10.1007/s00347-017-0598-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
BACKGROUND The aim of this study is to evaluate three refractive procedures: LenSx® (Alcon, Fort Worth, TX, USA) femto-laser in situ keratomileusis (LASIK), FEMTO LDV Z4® (Ziemer, Port, Switzerland) femto-LASIK, and photorefractive keratectomy (PRK) in terms of refractive outcome, perioperative complications, pain, and patient satisfaction. MATERIALS AND METHODS Data of 168 eyes (myopic n = 84) were included in this retrospective study. Of these, 54 eyes (n = 27, 33.85 ± 7.64 years) were treated with LenSx® femto-LASIK, 60 eyes (n = 30, 35.03 ± 7.46 years) with FEMTO LDV Z4® femto-LASIK, and 54 eyes (n = 27, 33.24 ± 8.52 years) with PRK. Photoablation was induced by a MEL80 Excimerlaser (Zeiss, Oberkochen, Germany). The corrected (Vsc) and uncorrected (Vcc) distance subjective visual acuity, corneal topography (Pentacam® HR; Wetzlar, Germany), and objective astigmatism (ARK-760A Refractometer ; Nidek, Fremont, CA, USA) were measured preoperatively, and 1 day, 1 week, 1 month, and 3 months postoperatively. Subjective pain (verbal rating scale) and patient satisfaction were also recorded. RESULTS Subjective Vsc showed significantly better results in both femto-LASIK cohorts compared to PRK (p < 0.05) 1 day and 1 week postoperatively. There was no significant difference between the groups in terms of spherical equivalent and astigmatism 3 months postoperatively. The LenSx® femto-LASIK caused flap complications. The highest patient satisfaction results were shown in the LDV Z4® group, followed by the LenSx® and PRK cohorts (p = 0.072). LDV Z4® femto-LASIK showed the lowest pain score 1 day postoperatively (p < 0.001). There was no significant correlation between target refraction and preoperative corneal thickness and astigmatism. DISCUSSION Femtosecond laser-assisted LASIK is an effective procedure enabling rapid rehabilitation of visual acuity with low postoperative pain compared to PRK. There is no difference between the three techniques regarding refractive outcome after 3 months follow-up. LDV Z4® femto-LASIK can be recommended, if available, due to its low intraoperative complication rate and higher patient satisfaction compared to LenSx® femto-LASIK.
Collapse
|
47
|
Brenner JE, Fadlallah A, Hatch KM, Choi C, Sayegh RR, Kouyoumjian P, Wu S, Frangieh GT, Melki SA. Accuracy of Visual Estimation of LASIK Flap Thickness. J Refract Surg 2017; 33:765-767. [DOI: 10.3928/1081597x-20170821-01] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2017] [Accepted: 08/08/2017] [Indexed: 11/20/2022]
|
48
|
|
49
|
Lei Y, Hou J, Zheng X. Redo surgery using IntraLase femtosecond laser for treating a decentered laser in situ keratomileusis flap. J Int Med Res 2017; 46:901-907. [PMID: 28875760 PMCID: PMC5971497 DOI: 10.1177/0300060517718989] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Objective Decentered flaps are rarely reported after femtosecond laser-assisted in situ keratomileusis flap procedures. We present a patient with a decentered flap after preparation of a corneal flap using the Femto LDV technique. Methods The 22-year-old man required a redo operation because of a decentered corneal flap. It was performed the same day at the patient's insistence and with his consent. The new corneal flap for the redo surgery was prepared using the femtosecond laser technique and IntraLase. Results Uncorrected visual acuity for each eye was 1.2 during the 12-month follow-up. The results of the Femtosecond laser technique showed good predictability and repeatability regarding the preparation of corneal flaps, but it still may cause some intraoperative complications. Conclusion Once redo surgery is needed, the size and depth of the initially prepared flap should be determined using anterior segment optical coherence tomography to pre-set the parameters for preparation of the redo flap.
Collapse
Affiliation(s)
- Yulin Lei
- Department of Ophthalmology, Jinan Mingshui Eye Hospital, Zhangqiu, China
| | - Jie Hou
- Department of Ophthalmology, Jinan Mingshui Eye Hospital, Zhangqiu, China
| | - Xiuyun Zheng
- Department of Ophthalmology, Jinan Mingshui Eye Hospital, Zhangqiu, China
| |
Collapse
|
50
|
The quality of systematic reviews about interventions for refractive error can be improved: a review of systematic reviews. BMC Ophthalmol 2017; 17:164. [PMID: 28870179 PMCID: PMC5584039 DOI: 10.1186/s12886-017-0561-9] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2017] [Accepted: 08/30/2017] [Indexed: 01/08/2023] Open
Abstract
BACKGROUND Systematic reviews should inform American Academy of Ophthalmology (AAO) Preferred Practice Pattern® (PPP) guidelines. The quality of systematic reviews related to the forthcoming Preferred Practice Pattern® guideline (PPP) Refractive Errors & Refractive Surgery is unknown. We sought to identify reliable systematic reviews to assist the AAO Refractive Errors & Refractive Surgery PPP. METHODS Systematic reviews were eligible if they evaluated the effectiveness or safety of interventions included in the 2012 PPP Refractive Errors & Refractive Surgery. To identify potentially eligible systematic reviews, we searched the Cochrane Eyes and Vision United States Satellite database of systematic reviews. Two authors identified eligible reviews and abstracted information about the characteristics and quality of the reviews independently using the Systematic Review Data Repository. We classified systematic reviews as "reliable" when they (1) defined criteria for the selection of studies, (2) conducted comprehensive literature searches for eligible studies, (3) assessed the methodological quality (risk of bias) of the included studies, (4) used appropriate methods for meta-analyses (which we assessed only when meta-analyses were reported), (5) presented conclusions that were supported by the evidence provided in the review. RESULTS We identified 124 systematic reviews related to refractive error; 39 met our eligibility criteria, of which we classified 11 to be reliable. Systematic reviews classified as unreliable did not define the criteria for selecting studies (5; 13%), did not assess methodological rigor (10; 26%), did not conduct comprehensive searches (17; 44%), or used inappropriate quantitative methods (3; 8%). The 11 reliable reviews were published between 2002 and 2016. They included 0 to 23 studies (median = 9) and analyzed 0 to 4696 participants (median = 666). Seven reliable reviews (64%) assessed surgical interventions. CONCLUSIONS Most systematic reviews of interventions for refractive error are low methodological quality. Following widely accepted guidance, such as Cochrane or Institute of Medicine standards for conducting systematic reviews, would contribute to improved patient care and inform future research.
Collapse
|