1
|
Karakaya K, Mutluay Ünal S. Evaluation of stress distribution of different marginal designs on PEEK and PEKK substructure materials, cortical and cancellous Bone:A finite element analysis. Comput Biol Med 2024; 178:108708. [PMID: 38861895 DOI: 10.1016/j.compbiomed.2024.108708] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2024] [Revised: 06/01/2024] [Accepted: 06/03/2024] [Indexed: 06/13/2024]
Abstract
BACKGROUND High-performance polymers are used in different fixed prosthesis treatments due to their many advantages such as biocompatibility, shock absorption ability, high fracture resistance. The effects of marginal design on the forces on high-performance polymers are unknown. This study aimed was to investigate the stress distribution of different marginal designs on Polyetheretherketone (PEEK) and Polyetherketoneketone (PEKK) substructure materials, cortical bone and cancellous bone by finite element analysis. METHODS A first maxillary molar tooth was modeled in 3D using the "3D Complex Render" method. Considering the ideal preparation conditions (Taper angle was 6°, step depth was 1 mm, occlusal reduction was 2 mm), four different configurations were modeled by changing the marginal design (chamfer, deep chamfer, shoulder 90°, shoulder 135°). PEEK, PEKK substructure, and composite superstructure were designed on created models. A total of 150 N oblique force from two points and a total of 300 N vertical force from three points were applied from occlusall. and the maximum principal stress, minimum principal stress, von Mises stress findings in the cortical bone, spongiose bone, and substructure were examined. The study was carried out by static linear analysis with a three-dimensional finite element stress analysis method. RESULTS The highest maximum principal stress value in the cortical bone was observed when the PEEK + Shoulder 135° step at vertical force. The highest minimum principal stress value in the cortical bone was observed when the PEEK + Shoulder 90° step, and PEEK + deep chamfer step at oblique force. The highest maximum principal stress value in spongiose bone was observed when the PEEK + Shoulder 90° step. The highest minimum principal stress value in spongiose bone was observed when the PEEK + deep chamfer step at vertical force. The highest von Mises stress value in the substructure was observed when the PEKK + Deep chamfer step at oblique force. The lowest maximum principal stress value in the cortical bone was observed when the PEKK + Shoulder 135° step at oblique force. The lowest minimum principal stress value in the cortical bone was observed when the PEEK + Shoulder 135° step, and PEKK + shoulder 135° step at vertical force. The lowest maximum principal stress value in spongiose bone was observed when the PEEK + Shoulder 90° step. The lowest minimum principal stress value in spongiose bone was observed when the PEEK + Shoulder 135° step and PEKK + Shoulder 135° step at vertical force. The lowest von Mises stress value in the substructure was observed when the PEEK + Deep chamfer step at vertical force. CONCLUSION When cortical and spongiose bone stress were evaluated, no destructive stress was observed. Considering the stresses occurring in the substructure the highest stress was observed in the chamfer step.
Collapse
Affiliation(s)
- Kevser Karakaya
- Afyonkarahisar Health Sciences University, Faculty of Dentistry, Department of Prosthodontics, Afyonkarahisar, Turkey.
| | - Server Mutluay Ünal
- Afyonkarahisar Health Sciences University, Faculty of Dentistry, Department of Prosthodontics, Afyonkarahisar, Turkey.
| |
Collapse
|
2
|
Adeeb Gabra EN, Sadek HMA, Hamdy AM, Wahsh MM. Effect of surface treatment and resin cement type on the bond strength of polyetheretherketone to lithium disilicate ceramic. BMC Oral Health 2024; 24:513. [PMID: 38698366 PMCID: PMC11064278 DOI: 10.1186/s12903-024-04269-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2024] [Accepted: 04/17/2024] [Indexed: 05/05/2024] Open
Abstract
BACKGROUND This study aims to evaluate the effect of surface treatment and resin cement on the shear bond strength (SBS) and mode of failure of polyetheretherketone (PEEK) to lithium disilicate ceramic (LDC). This is suggested to study alternative veneering of PEEK frameworks with a ceramic material. METHODS eighty discs were prepared from PEEK blank and from lithium disilicate ceramic. Samples were divided into four groups according to surface treatment: Group (A) air abraded with 110 μm Al2O3, Group (AP) air abrasion and primer application, Group (S) 98% sulfuric acid etching for 60 s, Group (SP) Sulfuric acid and primer. Each group was subdivided into two subgroups based on resin cement type used for bonding LDC:1) subgroup (L) self- adhesive resin cement and 2) subgroup (B) conventional resin cement (n = 10). Thermocycling was done for all samples. The bond strength was assessed using the shear bond strength test (SBS). Failure mode analysis was done at 50X magnification with a stereomicroscope. Samples were chosen from each group for scanning electron microscope (SEM). The three-way nested ANOVA followed by Tukey's post hoc test were used for statistical analysis of results. Comparisons of effects were done utilizing one way ANOVA and (p < 0.05). RESULTS The highest mean of shear bond strength values was demonstrated in Group of air abrasion with primer application using conventional resin cement (APB) (12.21 ± 2.14 MPa). Sulfuric acid groups showed lower shear bond strength values and the majority failed in thermocycling especially when no primer was applied. The failure mode analysis showed that the predominant failure type was adhesive failure between cement and PEEK, while the remaining was mixed failure between cement and PEEK. CONCLUSION The air abrasion followed by primer application and conventional resin cement used for bonding Lithium Disilicate to PEEK achieved the best bond strength. Primer application did not have an effect when self-adhesive resin cement was used in air-abraded groups. Priming step is mandatory whenever sulfuric acid etching surface treatment is utilized for PEEK.
Collapse
Affiliation(s)
- Engy N Adeeb Gabra
- Lecturer at Fixed Prosthodontics Department, Faculty of Dentistry, Ain Shams University, Cairo, Egypt.
| | | | | | - Marwa M Wahsh
- Fixed Prosthodontics Department, Faculty of Dentistry, Ain Shams University, Galala University, Cairo, Egypt
| |
Collapse
|
3
|
Ma T, Zhang J, Liu X, Sun S, Wu J. Effects of combined modification of sulfonation, oxygen plasma and silane on the bond strength of PEEK to resin. Dent Mater 2024; 40:e1-e11. [PMID: 38365456 DOI: 10.1016/j.dental.2024.02.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2023] [Revised: 01/30/2024] [Accepted: 02/06/2024] [Indexed: 02/18/2024]
Abstract
OBJECTIVE This study aimed to evaluate the combined effects of sulfonation, non-thermal oxygen plasma and silane on the shear bond strength (SBS) of PEEK to resin materials. MATERIALS AND METHODS Two hundred and eighty specimens were randomly divided into four groups: (A) untreated; (B) sulfonation for 60 s; (C) oxygen plasma for 20 min; (D) sulfonation for 60 s and oxygen plasma for 20 min. According to the instructions, 120 samples (N = 30) were coated with silane, adhesive, and resin composites. Each group of bonding specimens was divided into two subgroups (n = 15) to measure immediate and post-aging SBS. The surface morphology and the interface between the samples and adhesive were analyzed through SEM. Physicochemical characteristics of the surface and mechanical properties were determined through XPS, FTIR, light interferometry, contact angle measurement, and three-point bending tests. RESULTS Sulfonation produced a porous layer of approximately 20 µm thickness on the surface, and the oxygen plasma increased the O/C ratio and oxygen-containing groups of the sample surface. After coating with silane, the SBS values of sulfonated PEEK and plasma-treated PEEK increased (9.96 and 10.72 MPa, respectively), and dual-modified PEEK exhibited the highest SBS value (20.99 MPa), which was significantly higher than that of blank group (p > 0.01). After 10,000 thermal cycles, the dual-modified PEEK still displayed a favorable SBS (18.68 MPa). SIGNIFICANCE Sulfonation strengthened the mechanical interlocking between PEEK and the resin while oxygen plasma established a chemical bonding between silane and PEEK. This dual modification of the surface microstructure and chemical state synergistically improved the bond strength of PEEK to resin and resulted in considerable long-term effects.
Collapse
Affiliation(s)
- Tongtong Ma
- Department of Prosthodontics, School and Hospital of Stomatology, Cheeloo College of Medicine, Shandong University & Shandong Key Laboratory of Oral Tissue Regeneration & Shandong Engineering Research Center of Dental Materials and Oral Tissue Regeneration & Shandong Provincial Clinical Research Center for Oral Diseases, No. 44-1 Wenhua Road West, 250012, Jinan, Shandong, China
| | - Jiajia Zhang
- Department of Prosthodontics, School and Hospital of Stomatology, Cheeloo College of Medicine, Shandong University & Shandong Key Laboratory of Oral Tissue Regeneration & Shandong Engineering Research Center of Dental Materials and Oral Tissue Regeneration & Shandong Provincial Clinical Research Center for Oral Diseases, No. 44-1 Wenhua Road West, 250012, Jinan, Shandong, China
| | - Xueye Liu
- Department of Prosthodontics, School and Hospital of Stomatology, Cheeloo College of Medicine, Shandong University & Shandong Key Laboratory of Oral Tissue Regeneration & Shandong Engineering Research Center of Dental Materials and Oral Tissue Regeneration & Shandong Provincial Clinical Research Center for Oral Diseases, No. 44-1 Wenhua Road West, 250012, Jinan, Shandong, China
| | - Shuoyao Sun
- Department of Prosthodontics, School and Hospital of Stomatology, Cheeloo College of Medicine, Shandong University & Shandong Key Laboratory of Oral Tissue Regeneration & Shandong Engineering Research Center of Dental Materials and Oral Tissue Regeneration & Shandong Provincial Clinical Research Center for Oral Diseases, No. 44-1 Wenhua Road West, 250012, Jinan, Shandong, China
| | - Junling Wu
- Department of Prosthodontics, School and Hospital of Stomatology, Cheeloo College of Medicine, Shandong University & Shandong Key Laboratory of Oral Tissue Regeneration & Shandong Engineering Research Center of Dental Materials and Oral Tissue Regeneration & Shandong Provincial Clinical Research Center for Oral Diseases, No. 44-1 Wenhua Road West, 250012, Jinan, Shandong, China.
| |
Collapse
|
4
|
Abdulrazzaq S, Ismael Hamad T. Studying and Characterization of Coating of Zein-CaSiO 3 Composite on Polyetheretherketone Implant Material. Int J Dent 2024; 2024:1592439. [PMID: 38524145 PMCID: PMC10960650 DOI: 10.1155/2024/1592439] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2023] [Revised: 12/30/2023] [Accepted: 03/01/2024] [Indexed: 03/26/2024] Open
Abstract
Material-coated implants are placed in the bone and play an essential role in bone regeneration and rapid healing around implants. Polymeric matrix reinforced with ceramic materials is a promising composite material for coating implants. This study aims to determine the effect of mixing various concentrations of zein with CaSiO3 on polyetheretherketone (PEEK) as implant material. The coating was performed using the electrospray method. PEEK disks were used as a control group. The coated disks with different concentrations of zein-CaSiO3 (Group 1: 10% wt, 90% wt), (Group 2: 20% wt, 80% wt), and (Group 3%: 30% wt, 70% wt) were the experimental group. Each group was characterized by atomic force microscopy, field emission scanning electron microscope, Fourier-transform infrared spectroscopy, water contact angle, and adhesion strength. The lowest water contact angle was obtained for Group 1: 10% wt and 90% wt were (26.64° and 27.13°, respectively), and increasing amounts of zein in comparison to quantities of CaSiO3 resulted in increased adhesion strength of the composite material to the substrate. The current study suggested that the higher amount of zein compared to the amount of CaSiO3 mixture coating is achieved by electrospraying, a favorable candidate for coating implants compared to uncoated and coated disks with low concentrations of zein compared to concentrations of CaSiO3.
Collapse
Affiliation(s)
- Sama Abdulrazzaq
- Department of Prosthodontics, College of Dentistry, University of Baghdad, Baghdad, Iraq
| | - Thekra Ismael Hamad
- Department of Prosthodontics, College of Dentistry, University of Baghdad, Baghdad, Iraq
| |
Collapse
|
5
|
Jiang L, Li XY, Lu ZC, Yang S, Chen R, Yu H. Er:YAG laser settings for debonding zirconia restorations: An in vitro study. J Mech Behav Biomed Mater 2024; 151:106331. [PMID: 38176195 DOI: 10.1016/j.jmbbm.2023.106331] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Revised: 12/13/2023] [Accepted: 12/14/2023] [Indexed: 01/06/2024]
Abstract
This in vitro study aimed to determine the optimal frequency and energy settings for debonding zirconia restorations using an erbium-doped yttrium aluminum garnet (Er:YAG) laser. A total of 200 zirconia specimens (5 mm × 5 mm × 1.5 mm) were fabricated from two types of materials: (1) 3 mol% yttria oxide stabilized tetragonal zirconia polycrystalline (3Y-TZP) and (2) 5 mol% yttria oxide stabilized tetragonal zirconia polycrystalline (5Y-TZP). The zirconia specimens were bonded to dentin using resin cement (RelyX Ultimate, 3 M) and divided into 20 groups based on their laser treatments (n = 5). Er:YAG laser treatment was applied at various frequencies (10 Hz and 20 Hz) and energies (80 mJ, 100 mJ, 120 mJ, 140 mJ, 160 mJ, 180 mJ, 200 mJ, 220 mJ, 240 mJ, and 260 mJ). The time required to debond the specimens and the temperature changes that dentin underwent during the laser treatment were recorded. The surface morphologies of the debonded dentin and zirconia specimens were observed using scanning electron microscopy (SEM). Additional zirconia specimens were fabricated for 4-point flexural strength testing and surface roughness measurements. Statistical analyses were conducted using three-way analysis of variance (ANOVA) and Student-Newman-Keuls (SNK)-q tests (α = 0.05). The debonding time of each specimen varied between 4.8 and 160.4 s, with an average value of 59.2 s. The dentin temperature change for each specimen ranged from 2.3 to 3.6 °C, with an average value of 2.7 °C. The debonding time was significantly influenced by the zirconia material type and laser energy, but it was not affected by the laser frequency. Among the specimens, those made of 3Y-TZP needed significantly more time for debonding than 5Y-TZP. The optimal energies were 220 mJ for 3Y-TZP and 200 mJ for 5Y-TZP. The laser frequency, laser energy, and type of zirconia material had no effect on the dentin temperature change. Additionally, no surface alternations were observed on the dentin or zirconia materials after laser treatment. The surface roughness and flexural strength of the zirconia materials remained unchanged after laser treatment. In summary, Er:YAG laser treatment effectively and safely removes zirconia restorations without impacting their mechanical properties, with a safe temperature change of less than 5.6 °C. The optimum frequency and energy settings for debonding 3Y-TZP and 5Y-TZP restorations were found to be 10/20 Hz and 220 mJ and 10/20 Hz and 200 mJ, respectively.
Collapse
Affiliation(s)
- Lei Jiang
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Laboratory of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, China; Department of Prosthodontics & Research Center of Dental Esthetics and Biomechanics, Fujian Medical University, China
| | - Xue-Yu Li
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Laboratory of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, China; Department of Prosthodontics & Research Center of Dental Esthetics and Biomechanics, Fujian Medical University, China
| | - Zhi-Cen Lu
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Laboratory of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, China; Department of Prosthodontics & Research Center of Dental Esthetics and Biomechanics, Fujian Medical University, China
| | - Song Yang
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Laboratory of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, China; Department of Prosthodontics & Research Center of Dental Esthetics and Biomechanics, Fujian Medical University, China
| | - Run Chen
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Laboratory of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, China; Department of Prosthodontics & Research Center of Dental Esthetics and Biomechanics, Fujian Medical University, China.
| | - Hao Yu
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Laboratory of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, China; Department of Prosthodontics & Research Center of Dental Esthetics and Biomechanics, Fujian Medical University, China; Clinic of Conservative and Preventive Dentistry, Center for Dental Medicine, University of Zurich, Switzerland; Department of Applied Prosthodontics Graduate School of Biomedical Sciences, Nagasaki University, Japan
| |
Collapse
|
6
|
Peng TY, Shimoe S, Higo M, Kato M, Hirata I, Iwaguro S, Kaku M. Effect of laser engraving on shear bond strength of polyetheretherketone to indirect composite and denture-base resins. J Dent Sci 2024; 19:32-38. [PMID: 38303863 PMCID: PMC10829665 DOI: 10.1016/j.jds.2023.06.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Revised: 06/08/2023] [Indexed: 02/03/2024] Open
Abstract
Background/purpose Polyetheretherketone (PEEK) is a highly sought-after thermoplastic due to its exceptional mechanical properties and biocompatibility. However, bonding PEEK to indirect composite resin (ICR) or denture-based resin (DBR) can be challenging. Laser engraving technology has shown potential to improve bonding for other materials; thus, this study aims to evaluate its effectiveness for PEEK. Materials and methods The experiment involved preparing ingot-shaped PEEK samples, which were then categorized into four groups based on the treatment method employed: without treatment, air abrasion, sulfuric acid etching, and laser engraving (LS). Subsequently, the samples were bonded to ICR or DBR, and their shear bond strength (SBS) was tested with or without thermocycling using a universal testing machine. Furthermore, the failure mode was observed, with statistical analyses conducted to compare the results. Results The grid-like microslit structure of LS group displayed the highest SBS for bonding PEEK to ICR or DBR (P < 0.05). During the bonding of PEEK to ICR, resin residue and penetration into the microslits were frequently observed in the LS group, indicating cohesive failure. However, when PEEK was bonded to DBR, mixture failure was frequently observed without thermocycling. After thermocycling, only the LS group showed cohesive failure, while the majority of specimens exhibited mixture failure. Conclusion Laser engraving significantly improves the SBS between PEEK and both ICR and DBR. Furthermore, it was observed that resin had penetrated the microslits, indicating that laser engraving has great potential as a surface treatment method.
Collapse
Affiliation(s)
- Tzu-Yu Peng
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan
| | - Saiji Shimoe
- Department of Anatomy and Functional Restorations, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima City, Hiroshima, Japan
| | - Momoyo Higo
- Division of Dental Technician, Department of Clinical Practice and Support, Hiroshima University Hospital, Hiroshima, Japan
| | - Mai Kato
- Course for Oral Engineering, Department of Oral Health Science, School of Dentistry, Hiroshima University, Hiroshima City, Hiroshima, Japan
| | - Isao Hirata
- Department of Biomaterials, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima City, Hiroshima, Japan
| | - Shogo Iwaguro
- Division of Dental Technician, Department of Clinical Practice and Support, Hiroshima University Hospital, Hiroshima, Japan
| | - Masato Kaku
- Department of Anatomy and Functional Restorations, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima City, Hiroshima, Japan
| |
Collapse
|
7
|
Alqahtani WMS, Abdul NS, Aslam K, Alanazi A, Ansary N, Alresayes SS, Samran A, Niazi FH. PEEK surface treatment on surface roughness and bond integrity to composite resin utilizing Er: YAG, Rosebengal activated by PDT, and aluminum trioxide particles. Photodiagnosis Photodyn Ther 2023; 44:103879. [PMID: 37923284 DOI: 10.1016/j.pdpdt.2023.103879] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Revised: 10/27/2023] [Accepted: 10/31/2023] [Indexed: 11/07/2023]
Abstract
AIMS To evaluate the impact of conditioning protocols, aluminum trioxide (Al2O3), Er:YAG laser (EYL), and Rosebengal (RB), on the surface roughness (Ra) and shear bond strength (SBS) of polyetheretherketone (PEEK) attached to composite restorations. METHOD Eighty PEEK discs in total were produced and then divided into four groups (n = 20). Group1:Sulfuric acid (SA), Group 2: PDT (RB), Group 3: Al2O3, Group 4 EYL, respectively. The Ra of PEEK discs was evaluated using the surface profilometer. After being luted, the discs were attached to composite resin discs. After that, samples were put to SBS testing on a Universal testing apparatus. A stereo microscope was also used to evaluate the type of breakdown. The data were analyzed using Tukey's test and one-way analysis of variance. RESULTS The SA treated group exhibited the highest Ra. Nevertheless, the RB specimens activated by PDT treatment had the lowest mean Ra score. The group that received the treatment of SA exhibited the highest average score of SBS. In contrast, specimens treated with PDT and activated by RB exhibited the lowest levels of bond fidelity. Cohesive failure emerges as the prevailing kind of fracture within the various groups subjected to testing. CONCLUSION The utilization of Al2O3, RB activated by PDT, and EYL shows promise as a viable substitute for Sulfuric acid in enhancing the bond integrity of composite cement and surface roughness in PEEK materials.
Collapse
Affiliation(s)
- Waleed M S Alqahtani
- Associate Professor, Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha, Saudi Arabia.
| | - Nishath Sayed Abdul
- Department of OMFS and Diagnostic Sciences (Oral Pathology), Faculty of Dentistry, Riyadh Elm University, Riyadh, Saudi Arabia.
| | - Kashif Aslam
- Department of Prosthodontics, Dow Dental College, Dow University of Health Sciences, Pakistan.
| | | | - Nisren Ansary
- College of Dentistry, Dar Al Uloom University, Riyadh, Saudi Arabia
| | - Saad Saleh Alresayes
- Department of Prosthetic Dental Sciences, King Saud University College of Dentistry, Riyadh, Saudi Arabia.
| | - Abdulaziz Samran
- Department of Prosthetic and Restorative Dental Sciences, College of Dentistry, Dar Al Uloom University, Riyadh, Saudi Arabia
| | - Fayez Hussain Niazi
- Department of Prosthetic and Restorative Dental Sciences, College of Dentistry, Dar Al Uloom University, Riyadh, Saudi Arabia.
| |
Collapse
|
8
|
Lyu X, Kanda R, Tsuda S, Hashimoto Y, Fujii T, Kashiwagi K. Novel Carboxylation Method for Polyetheretherketone (PEEK) Surface Modification Using Friedel-Crafts Acylation. Int J Mol Sci 2023; 24:15651. [PMID: 37958636 PMCID: PMC10650194 DOI: 10.3390/ijms242115651] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Revised: 10/23/2023] [Accepted: 10/25/2023] [Indexed: 11/15/2023] Open
Abstract
Recently, polyetheretherketone (PEEK) has shown promising dental applications. Surface treatment is essential for dental applications owing to its poor surface energy and wettability; however, no consensus on an effective treatment method has been achieved. In this study, we attempted to carboxylate PEEK sample surfaces via Friedel-Crafts acylation using succinic anhydride and AlBr3. The possibility of further chemical modifications using carboxyl groups was examined. The samples were subjected to dehydration-condensation reactions with 1H,1H-pentadecafluorooctylamine and N,N'-dicyclohexylcarbodiimide. Furthermore, the sample's surface properties at each reaction stage were evaluated. An absorption band in the 3300-3500 cm-1 wavenumber region was observed. Additionally, peak suggestive of COOH was observed in the sample spectra. Secondary modification diminished the absorption band in 3300-3500 cm-1 and a clear F1s signal was observed. Thus, Friedel-Crafts acylation with succinic anhydride produced carboxyl groups on the PEEK sample surfaces. Further chemical modification of the carboxyl groups by dehydration-condensation reactions is also possible. Thus, a series of reactions can be employed to impart desired chemical structures to PEEK surfaces.
Collapse
Affiliation(s)
- Xinghui Lyu
- Department of Fixed Prosthodontics and Occlusion, Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Osaka, Japan; (X.L.); (T.F.); (K.K.)
| | - Ryuhei Kanda
- Division of Creative and Integrated Medicine, Advanced Medicine Research Center, Translational Research Institute for Medical Innovation (TRIMI), Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Osaka, Japan;
| | - Susumu Tsuda
- Department of Chemistry, Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Osaka, Japan;
| | - Yoshiya Hashimoto
- Division of Creative and Integrated Medicine, Advanced Medicine Research Center, Translational Research Institute for Medical Innovation (TRIMI), Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Osaka, Japan;
- Department of Biomaterial, Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Osaka, Japan
| | - Takamasa Fujii
- Department of Fixed Prosthodontics and Occlusion, Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Osaka, Japan; (X.L.); (T.F.); (K.K.)
| | - Kosuke Kashiwagi
- Department of Fixed Prosthodontics and Occlusion, Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Osaka, Japan; (X.L.); (T.F.); (K.K.)
| |
Collapse
|
9
|
Alsmael MA, Mohammed Al-Khafaji A. Improving Surface Properties of PEEK for Dental Applications by Using Piranha Solution. Int J Dent 2023; 2023:7840601. [PMID: 37771363 PMCID: PMC10533222 DOI: 10.1155/2023/7840601] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2023] [Revised: 08/06/2023] [Accepted: 09/01/2023] [Indexed: 09/30/2023] Open
Abstract
Background "Polyetheretherketone (PEEK)" is a biocompatible, high-strength polymer that is well-suited for use in dental applications due to its unique properties. However, achieving good adhesion between PEEK and hydrophilic materials such as dental adhesives or cement can be challenging. Also, this hydrophobicity may affect the use of PEEK as an implant material. Surface treatment or conditioning is often necessary to improve surface properties. The piranha solution is the treatment of choice to be explored for this purpose. Methods PEEK disks of 10 mm diameter and 2 mm thickness were used in this study. Those samples were divided into five groups (each group has five samples). The first is the control group, in which no acid treatment was used; the second group undergoes sulfuric acid treatment. The remaining three groups were treated with Piranha solution; each group used a different concentration (1 : 3, 1 : 5, and 1 : 7 hydrogen peroxide to sulfuric acid, respectively). The period of treatment was 60 s for all groups. Wettability and surface roughness tests were done for the five groups. In statistical analysis, Shapiro-Wilk test was used to check the assumption of normality and to determine the statistical significance among groups; a one-way analysis of variance was employed. Subsequently, for multiple comparisons, Tukey's honestly significant difference post hoc test was performed. Results The Piranha solution treatment groups showed a higher wettability compared to the control group and the group treated with sulfuric acid. Additionally, the Piranha solution treatment with a higher concentration of hydrogen peroxide (1 : 3) resulted in greater improvement in surface roughness compared to the control group and the lower concentration groups (1 : 5 and 1 : 7), while the sulfuric acid treated group showed the highest surface roughness. Conclusion The results of this study suggest that the piranha solution can be an effective method for improving the surface characteristics of PEEK to be used in different dental applications, especially as a dental implant material, due to the increase in wettability and surface roughness.
Collapse
Affiliation(s)
- Mohammed A. Alsmael
- Department of Prosthodontics, College of Dentistry, University of Baghdad, Baghdad, Iraq
| | | |
Collapse
|
10
|
Peng TY, Ma TL, Lee IT, Wu SH, Mine Y, Lin CC. Enhancing Dental Cement Bond Strength with Autofocus-Laser-Cutter-Generated Grooves on Polyetheretherketone Surfaces. Polymers (Basel) 2023; 15:3670. [PMID: 37765524 PMCID: PMC10536987 DOI: 10.3390/polym15183670] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Revised: 08/21/2023] [Accepted: 08/30/2023] [Indexed: 09/29/2023] Open
Abstract
Polyetheretherketone (PEEK) is widely used in dentistry owing to its exceptional properties, including its natural appearance; however, existing surface treatment methods for bonding PEEK have limitations. Autofocus laser cutters, known for their precise engraving and cutting capabilities, offer potential for surface treatment of PEEK; thus, the objective of this study was to investigate the creation of laser groove structures on PEEK to enhance its bonding capability with dental resin cement. A dental computer-aided design and manufacturing system was used to fabricate PEEK samples, and three groove patterns (circle, line, and grid) were generated on PEEK surfaces, with air-abrasion used as the control group. The surface characteristics, cell viability, and bond strength were evaluated, and the data were statistically analyzed using one-way analysis of variance and post hoc Tukey's tests (α = 0.05). Laser-treated PEEK exhibited a uniform texture with a groove depth of approximately 39.4 µm, hydrophobic properties with a contact angle exceeding 90°, a surface roughness of 7.3-12.4 µm, consistent topography, and comparable cell viability compared with untreated PEEK. Despite a decrease in bond strength after thermal cycling, no significant intergroup differences were observed, except for the line-shaped laser pattern. These findings indicate that the autofocus laser cutter effectively enhances the surface characteristics of PEEK by creating a uniform texture and grooves, showing promise in improving bonding properties, even considering the impact of thermal cycling effects.
Collapse
Affiliation(s)
- Tzu-Yu Peng
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei 11031, Taiwan; (T.-Y.P.); (S.-H.W.)
- Research Center of Digital Oral Science and Technology, College of Oral Medicine, Taipei Medical University, Taipei 11031, Taiwan
| | - Tien-Li Ma
- Research Center of Digital Oral Science and Technology, College of Oral Medicine, Taipei Medical University, Taipei 11031, Taiwan
| | - I-Ta Lee
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei 11031, Taiwan; (T.-Y.P.); (S.-H.W.)
| | - Sheng-Han Wu
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei 11031, Taiwan; (T.-Y.P.); (S.-H.W.)
| | - Yuichi Mine
- Department of Medical Systems Engineering, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima 734-8553, Japan;
| | - Chia-Cheng Lin
- Department of Dentistry, Shin Kong Wu Ho-Su Memorial Hospital, Taipei 11101, Taiwan
- School of Dental Technology, College of Oral Medicine, Taipei Medical University, Taipei 11031, Taiwan
| |
Collapse
|
11
|
Qamar Z, Zeeshan T, Alqahtani WMS, Alanazi A, Khalid Aqeel Almejlad N, Ahmed Khan T, Samran A. Modulation of implants PEEK to composite resin shear bond strength and surface roughness on pre-treatment with contemporary air abrasion techniques vs photodynamic therapy vs conventional diamond grit bur. Photodiagnosis Photodyn Ther 2023; 43:103689. [PMID: 37414110 DOI: 10.1016/j.pdpdt.2023.103689] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2023] [Revised: 05/30/2023] [Accepted: 06/01/2023] [Indexed: 07/08/2023]
Abstract
AIM The chief aim of the study was to determine/equate the surface roughness (SRa) and shear bond strength (BS) of pretreated PEEK discs with contemporary air abrasion techniques, photodynamic (PD) therapy by curcumin photosensitizer (PS) and conventional diamond grit straight fissure bur adhered to the composite resin discs. MATERIAL AND METHOD Two hundred discs of PEEK were prepared of 6 mm × 2 mm × 10 mm dimension. The discs were randomly divided into five groups (n = 40) for treatment, Group I: treatment with deionized distilled water (control group); Group II: PD therapy using curcumin PS; Group III: discs treated and abraded with air-borne particles (ABP) silica (30 μm particle size) modified alumina (Al); Group IV: ABP of alumina (110 μm particle size); and Group V: The PEEK were finished with 600-μm grit size straight diamond cutting bur installed in high speed hand-piece. The surface profilometer was used to evaluate the values of surface roughness (SRa) of pretreated PEEK discs. The discs were luted and bonded to discs of composite resin. The bonded PEEK samples were placed in Universal testing machine to evaluate shear BS. The type of BS failure for PEEK discs pre-treated with five regimes respectively was evaluated under stereo-microscope. The data was statistically analyzed using one-way ANOVA and the comparisons between mean values of shear BS were evaluated by Tukey's test (ρ≤0.05). RESULTS The PEEK samples pre-treated with diamond cutting straight fissure burs displayed statistically significant highest value of SRa values (3.258± 0.785 µm). Similarly, the shear BS was observed to be higher for the PEEK discs pre-treated with straight fissure bur (22.37±0.78 MPa). A comparable difference but not statistically significant difference was observed between PEEK discs pre-treated by curcumin PS and ABP-silica modified alumina (ρ ≥ 0.05). CONCLUSION PEEK discs pre-treated with diamond grit straight fissure bur displayed highest values of SRa and shear BS. It was trailed by ABP-Al pre-treated discs; whereas the SRa and shear BS values for the discs pre-treated with ABP-silica modified Al and curcumin PS did not show competitive difference.
Collapse
Affiliation(s)
- Zeeshan Qamar
- Department of O&MFS and Diagnostic Sciences, Faculty of Dentistry, Riyadh Elm University, Riyadh, Saudi Arabia.
| | - Tayyaba Zeeshan
- Department of Oral and Craniofacial Sciences, Faculty of Dentistry, University of Malaya, Kuala Lumpur, Malaysia
| | - Waleed M S Alqahtani
- Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | | | | | - Tanveer Ahmed Khan
- Faculty of Pharmacy, Riyadh Elm University, Riyadh, Kingdom of Saudi Arabia
| | - Abdulaziz Samran
- Department of Restorative and Prosthetic Dental Sciences, College of Dentistry, Dar Aluloom University, Riyadh, KSA; Department of Prosthodontics, College of Dentistry, Ibb University, Ibb, Yemen
| |
Collapse
|
12
|
Su Q, Qiao Y, Xiao Y, Yang S, Wu H, Li J, He X, Hu X, Yang H, Yong X. Research progress of 3D printed poly (ether ether ketone) in the reconstruction of craniomaxillofacial bone defects. Front Bioeng Biotechnol 2023; 11:1259696. [PMID: 37662437 PMCID: PMC10469012 DOI: 10.3389/fbioe.2023.1259696] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2023] [Accepted: 08/07/2023] [Indexed: 09/05/2023] Open
Abstract
The clinical challenge of bone defects in the craniomaxillofacial region, which can lead to significant physiological dysfunction and psychological distress, persists due to the complex and unique anatomy of craniomaxillofacial bones. These critical-sized defects require the use of bone grafts or substitutes for effective reconstruction. However, current biomaterials and methods have specific limitations in meeting the clinical demands for structural reinforcement, mechanical support, exceptional biological performance, and aesthetically pleasing reconstruction of the facial structure. These drawbacks have led to a growing need for novel materials and technologies. The growing development of 3D printing can offer significant advantages to address these issues, as demonstrated by the fabrication of patient-specific bioactive constructs with controlled structural design for complex bone defects in medical applications using this technology. Poly (ether ether ketone) (PEEK), among a number of materials used, is gaining recognition as a feasible substitute for a customized structure that closely resembles natural bone. It has proven to be an excellent, conformable, and 3D-printable material with the potential to replace traditional autografts and titanium implants. However, its biological inertness poses certain limitations. Therefore, this review summarizes the distinctive features of craniomaxillofacial bones and current methods for bone reconstruction, and then focuses on the increasingly applied 3D printed PEEK constructs in this field and an update on the advanced modifications for improved mechanical properties, biological performance, and antibacterial capacity. Exploring the potential of 3D printed PEEK is expected to lead to more cost-effective, biocompatible, and personalized treatment of craniomaxillofacial bone defects in clinical applications.
Collapse
Affiliation(s)
- Qiao Su
- Key Laboratory of Birth Defects and Related Diseases of Women and Children, Department of Paediatrics, West China Second University Hospital, State Key Laboratory of Biotherapy and Collaborative Innovation Center of Biotherapy, Sichuan University, Chengdu, Sichuan, China
- State Key Laboratory of Oral Diseases and National Clinical Research Center for Oral Diseases and West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan, China
- West China School of Stomatology, Sichuan University, Chengdu, Sichuan, China
| | - Yixin Qiao
- Department of Otolaryngology-Head and Neck Surgery, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Yile Xiao
- Beijing Shijitan Hospital, Capital Medical University, Beijing, China
| | - Shuhao Yang
- Clinical Medical College and Affiliated Hospital of Chengdu University, Chengdu, Sichuan, China
| | - Haoming Wu
- Clinical Medical College and Affiliated Hospital of Chengdu University, Chengdu, Sichuan, China
| | - Jianan Li
- State Key Laboratory of Biotherapy, State Key Laboratory and Collaborative Innovation Center of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Xinlong He
- State Key Laboratory of Biotherapy, State Key Laboratory and Collaborative Innovation Center of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Xulin Hu
- Clinical Medical College and Affiliated Hospital of Chengdu University, Chengdu, Sichuan, China
- State Key Laboratory of Biotherapy, State Key Laboratory and Collaborative Innovation Center of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Hui Yang
- State Key Laboratory of Oral Diseases and National Clinical Research Center for Oral Diseases and West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan, China
| | - Xin Yong
- Key Laboratory of Birth Defects and Related Diseases of Women and Children, Department of Paediatrics, West China Second University Hospital, State Key Laboratory of Biotherapy and Collaborative Innovation Center of Biotherapy, Sichuan University, Chengdu, Sichuan, China
| |
Collapse
|
13
|
Cevik P, Yildirim AZ, Demir Sevinc EH, Gonder A, Kiat-Amnuay S. Using Peek as a Framework Material for Maxillofacial Silicone Prosthesis: An In Vitro Study. Polymers (Basel) 2023; 15:2694. [PMID: 37376341 DOI: 10.3390/polym15122694] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Revised: 06/09/2023] [Accepted: 06/12/2023] [Indexed: 06/29/2023] Open
Abstract
There are often bonding problems between acrylic resins and silicone. PEEK (polyetheretherketone), which is a high-performance polymer, has great potential for the implant, and fixed or removable prosthodontics. The aim of this study was to evaluate the effect of different surface treatments on PEEK to be bonded to maxillofacial silicone elastomers. A total of 48 specimens were fabricated from either PEEK or PMMA (Polymethylmethacrylate) (n = 8). PMMA specimens acted as a positive control group. PEEK specimens were divided into five study groups as surface treatments as control PEEK, silica-coating, plasma etching, grinding, or nano-second fiber laser. Surface topographies were evaluated by scanning electron microscopy (SEM). A platinum-primer was used on top of all specimens including control groups prior to silicone polymerization. The peel bond strength of the specimens to a platinum-type silicone elastomer was tested at a cross-head speed of 5 mm/min. The data were statistically analyzed (α = 0.05). The control PEEK group showed the highest bond strength (p < 0.05) among the groups. No statistical difference was found between control PEEK, grinding, or plasma etching groups (p > 0.05). The lowest bond strength was seen in the laser group, which was not statistically different from silica-coating (p > 0.05), and statistically different from control PEEK, grinding, or plasma groups (p < 0.05). Positive control PMMA specimens had statistically lower bond strength than either control PEEK or plasma etching groups (p < 0.05). All specimens exhibited adhesive failure after a peel test. The study results indicate that PEEK could serve as a potential alternative substructure for implant-retained silicone prostheses.
Collapse
Affiliation(s)
- Pinar Cevik
- Department of Prosthodontics, Faculty of Dentistry, Gazi University, Ankara 06490, Turkey
- Department of General Practice and Dental Public Health, School of Dentistry, The University of Texas Health Science Center at Houston, Houston, TX 77054, USA
- Houston Center of Biomaterials and Biomimetics, Houston, TX 77054, USA
| | - Arzu Zeynep Yildirim
- Department of Prosthodontics, Faculty of Dentistry, Gazi University, Ankara 06490, Turkey
| | | | - Aykut Gonder
- Department of Prosthodontics, Faculty of Dentistry, Gazi University, Ankara 06490, Turkey
| | - Sudarat Kiat-Amnuay
- Department of General Practice and Dental Public Health, School of Dentistry, The University of Texas Health Science Center at Houston, Houston, TX 77054, USA
- Houston Center of Biomaterials and Biomimetics, Houston, TX 77054, USA
| |
Collapse
|
14
|
Alkhudhairy F, Aljamhan AS. Surface conditioning of PEEK post using Nd: YVO4 laser, Photodynamic therapy, and sulfuric acid on the pushout bond strength to canal dentin. Photodiagnosis Photodyn Ther 2023; 42:103601. [PMID: 37169168 DOI: 10.1016/j.pdpdt.2023.103601] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Revised: 05/05/2023] [Accepted: 05/08/2023] [Indexed: 05/13/2023]
Abstract
AIM To assess the push-out bond strength (PBS) of polyetheretherketone (PEEK) post-to-root dentin using post-surface conditioners i.e., Neodymium-doped yttrium orthovanadate (Nd: YVO4) and Riboflavin (RF) and Rose Bengal (RB) mediated photodynamic therapy (PDT) compared to sulfuric acid (SA). MATERIALS AND METHODS Decoronation of forty human single-rooted premolar teeth was performed. Followed by chamber opening, working length (WL) was established at 15 mm. Root canal preparation was completed using ProTaper Ni-Ti rotary system till F3 finishing file along with root canal disinfection. The canals were dried with paper cones followed by obturation using gutta-percha (GP) and AH sealer. Post space was prepared by drilling out 11 mm of GP using a Gates Glidden drill #3. PEEK posts were fabricated using the CAD-CAM system and then randomly allocated into 4 groups based on the post-surface conditioning (n=10). Group 1: SA, group 2: PDT RF, group 3: PDT RB, and group 4: Nd: YVO4 laser. The PEEK post was then cemented in their respective canal. PBS and failure mode assessment were performed using a universal testing machine and stereomicroscope at 40x magnification. The SBS data set was subjected to a one-way analysis of variance (ANOVA) and Tukey's Post Hoc test at a significance level of 0.05. RESULTS The samples in group 4 (Nd: YVO4 laser) coronal third (7.99±0.24 MPa) demonstrated the highest PBS. The apical third of samples in group 1 PEEK post surface conditioned with SA (5.15± 0.52 MPa) exhibited the minimum values of PBS. Intergroup comparison analysis showed that samples in group 1 (SA), group 2 (RF activated by PDT), group 3 (RB activated by PDT), and group 4 (Nd: YVO4 laser) demonstrated comparable outcomes of bond scores (p>0.05) CONCLUSION: Neodymium-doped yttrium orthovanadate (Nd: YVO4) and riboflavin and Rose bengal activated by photodynamic therapy (PDT) have been investigated as potential alternatives for the surface conditioning of PEEK (polyetheretherketone) posts.
Collapse
Affiliation(s)
- Fahad Alkhudhairy
- Restorative Dental Sciences Department, College of Dentistry, King Saud University, Riyadh, Saudi Arabia.
| | - Abdullah S Aljamhan
- Restorative Dental Sciences Department, College of Dentistry, King Saud University, Riyadh, Saudi Arabia.
| |
Collapse
|
15
|
Hata K, Komagata Y, Nagamatsu Y, Masaki C, Hosokawa R, Ikeda H. Bond Strength of Sandblasted PEEK with Dental Methyl Methacrylate-Based Cement or Composite-Based Resin Cement. Polymers (Basel) 2023; 15:polym15081830. [PMID: 37111977 PMCID: PMC10145247 DOI: 10.3390/polym15081830] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 04/07/2023] [Accepted: 04/08/2023] [Indexed: 04/29/2023] Open
Abstract
Poly-ether-ether-ketone (PEEK) is commonly employed in dental prostheses owing to its excellent mechanical properties; however, it is limited by its low bond strength with dental resin cement. This study aimed to clarify the type of resin cement most suitable for bonding to PEEK: methyl methacrylate (MMA)-based resin cement or composite-based resin cement. For this purpose, two MMA-based resin cements (Super-Bond EX and MULTIBOND II) and five composite-based resin cements (Block HC Cem, RelyX Universal Resin Cement, G-CEM LinkForce, Panavia V5, and Multilink Automix) were used in combination with appropriate adhesive primers. A PEEK block (SHOFU PEEK) was initially cut, polished, and sandblasted with alumina. The sandblasted PEEK was then bonded to resin cement with adhesive primer according to the manufacturer's instructions. The resulting specimens were immersed in water at 37 °C for 24 h, followed by thermocycling. Subsequently, the tensile bond strengths (TBSs) of the specimens were measured; the TBSs of the composite-based resin cements after thermocycling were found to be zero (G-CEM LinkForce, Panavia V5, and Multilink Automix), 0.03 ± 0.04 (RelyX Universal Resin Cement), or 1.6 ± 2.7 (Block HC Cem), whereas those of Super-Bond and MULTIBOND were 11.9 ± 2.6 and 4.8 ± 2.3 MPa, respectively. The results demonstrated that MMA-based resin cements exhibited stronger bonding to PEEK than composite-based resin cements.
Collapse
Affiliation(s)
- Kentaro Hata
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University, Kitakyushu 803-8580, Japan
- Division of Oral Reconstruction and Rehabilitation, Department of Oral Functions, Kyushu Dental University, Kitakyushu 803-8580, Japan
| | - Yuya Komagata
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University, Kitakyushu 803-8580, Japan
| | - Yuki Nagamatsu
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University, Kitakyushu 803-8580, Japan
| | - Chihiro Masaki
- Division of Oral Reconstruction and Rehabilitation, Department of Oral Functions, Kyushu Dental University, Kitakyushu 803-8580, Japan
| | - Ryuji Hosokawa
- Division of Oral Reconstruction and Rehabilitation, Department of Oral Functions, Kyushu Dental University, Kitakyushu 803-8580, Japan
| | - Hiroshi Ikeda
- Division of Biomaterials, Department of Oral Functions, Kyushu Dental University, Kitakyushu 803-8580, Japan
| |
Collapse
|
16
|
Przykaza K, Jurak M, Kalisz G, Mroczka R, Wiącek AE. Characteristics of Hybrid Bioglass-Chitosan Coatings on the Plasma Activated PEEK Polymer. Molecules 2023; 28:molecules28041729. [PMID: 36838717 PMCID: PMC9967460 DOI: 10.3390/molecules28041729] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 01/26/2023] [Accepted: 01/31/2023] [Indexed: 02/17/2023] Open
Abstract
Polyetheretherketone (PEEK) is a biocompatible, chemically and physically stable radiolucent polymer that exhibits a similar elastic modulus to the normal human bone, making it an attractive orthopedic implant material. However, PEEK is biologically inert, preventing strong enough bonding with the surrounding bone tissue when implanted in vivo. Surface modification and composite preparation are the two main strategies for the improvement of the bioactivity of PEEK. In this study, the plasma activated PEEK surfaces with the embedded bioglass, chitosan, and bioglass-chitosan mixed layers applying from the solution dip-coating technique were investigated. The most prominent factors affecting the coating biocompatibility are strictly connected with the composition of its outer surface (its charge and functional groups), hydrophilic-hydrophobic character, wettability and surface free energy, and topography (size of pores/substructures, roughness, stiffness), as well as the personal characteristics of the patient. The obtained surfaces were examined in terms of wettability and surface-free energy changes. Additionally, FTIR (Fourier Transformation Infrared Spectrometry) and SIMS (Secondary Ion Mass Spectrometry) were applied to establish and control the coating composition. Simultaneously the structure of coatings was visualized with the aid of SEM (Scanning Electron Microscopy). Finally, the obtained systems were incubated in SBF (Simulated Body Fluid) to verify the modifications' influence on the bioactivity/biocompatibility of the PEEK surface. Different structures with variable compositions, as well as changes of the wettability, were observed depending on the applied modification. In addition, the incubation in SBF suggested that the bioglass-chitosan ratio influenced the formation of apatite-like structures on the modified PEEK surfaces.
Collapse
Affiliation(s)
- Kacper Przykaza
- Department of Interfacial Phenomena, Institute of Chemical Sciences, Faculty of Chemistry, Maria Curie-Sklodowska University, Maria Curie-Sklodowska Sq. 3, 20-031 Lublin, Poland
- Department of Bioanalytics, Faculty of Biomedicine, Medical University of Lublin, Jaczewskiego St. 8b, 20-090 Lublin, Poland
- Correspondence:
| | - Małgorzata Jurak
- Department of Interfacial Phenomena, Institute of Chemical Sciences, Faculty of Chemistry, Maria Curie-Sklodowska University, Maria Curie-Sklodowska Sq. 3, 20-031 Lublin, Poland
| | - Grzegorz Kalisz
- Independent Unit of Spectroscopy and Chemical Imaging, Medical University of Lublin, Chodzki St. 4a, 20-093 Lublin, Poland
| | - Robert Mroczka
- Laboratory of X-ray Optics, Centre for Interdisciplinary Research, The John Paul II Catholic University of Lublin, Konstantynow St. 1J, 20-708 Lublin, Poland
| | - Agnieszka Ewa Wiącek
- Department of Interfacial Phenomena, Institute of Chemical Sciences, Faculty of Chemistry, Maria Curie-Sklodowska University, Maria Curie-Sklodowska Sq. 3, 20-031 Lublin, Poland
| |
Collapse
|
17
|
Luo C, Liu Y, Peng B, Chen M, Liu Z, Li Z, Kuang H, Gong B, Li Z, Sun H. PEEK for Oral Applications: Recent Advances in Mechanical and Adhesive Properties. Polymers (Basel) 2023; 15:386. [PMID: 36679266 PMCID: PMC9864167 DOI: 10.3390/polym15020386] [Citation(s) in RCA: 25] [Impact Index Per Article: 25.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Revised: 01/06/2023] [Accepted: 01/07/2023] [Indexed: 01/15/2023] Open
Abstract
Polyetheretherketone (PEEK) is a thermoplastic material widely used in engineering applications due to its good biomechanical properties and high temperature stability. Compared to traditional metal and ceramic dental materials, PEEK dental implants exhibit less stress shielding, thus better matching the mechanical properties of bone. As a promising medical material, PEEK can be used as implant abutments, removable and fixed prostheses, and maxillofacial prostheses. It can be blended with materials such as fibers and ceramics to improve its mechanical strength for better clinical dental applications. Compared to conventional pressed and CAD/CAM milling fabrication, 3D-printed PEEK exhibits excellent flexural and tensile strength and parameters such as printing temperature and speed can affect its mechanical properties. However, the bioinert nature of PEEK can make adhesive bonding difficult. The bond strength can be improved by roughening or introducing functional groups on the PEEK surface by sandblasting, acid etching, plasma treatment, laser treatment, and adhesive systems. This paper provides a comprehensive overview of the research progress on the mechanical properties of PEEK for dental applications in the context of specific applications, composites, and their preparation processes. In addition, the research on the adhesive properties of PEEK over the past few years is highlighted. Thus, this review aims to build a conceptual and practical toolkit for the study of the mechanical and adhesive properties of PEEK materials. More importantly, it provides a rationale and a general new basis for the application of PEEK in the dental field.
Collapse
Affiliation(s)
- Chengfeng Luo
- School of Stomatology, China Medical University, Shenyang 110002, China
- Liaoning Provincial Key Laboratory of Oral Diseases, Shenyang 110002, China
| | - Ying Liu
- The Affiliated Taian City Central Hospital of Qingdao University, Taian 271000, China
| | - Bo Peng
- School of Stomatology, China Medical University, Shenyang 110002, China
- Liaoning Provincial Key Laboratory of Oral Diseases, Shenyang 110002, China
| | - Menghao Chen
- School of Stomatology, China Medical University, Shenyang 110002, China
- Liaoning Provincial Key Laboratory of Oral Diseases, Shenyang 110002, China
| | - Zhaogang Liu
- The Affiliated Taian City Central Hospital of Qingdao University, Taian 271000, China
| | - Zhanglong Li
- School of Stomatology, China Medical University, Shenyang 110002, China
- Liaoning Provincial Key Laboratory of Oral Diseases, Shenyang 110002, China
| | - Hai Kuang
- Department of Oral and Maxillofacial Surgery, College of Stomatology, Guangxi Medical University, Nanning 530021, China
- Key Laboratory of Research and Application of Stomatological Equipment (College of Stomatology, Guangxi Medical University), Education Department of Guangxi Zhuang Autonomous Region, Nanning 530021, China
| | - Baijuan Gong
- School of Stomatology, China Medical University, Shenyang 110002, China
- Liaoning Provincial Key Laboratory of Oral Diseases, Shenyang 110002, China
| | - Zhimin Li
- School of Stomatology, China Medical University, Shenyang 110002, China
- Liaoning Provincial Key Laboratory of Oral Diseases, Shenyang 110002, China
| | - Hongchen Sun
- Hospital of Stomatology, Jilin University, Changchun 130021, China
| |
Collapse
|
18
|
Pidhatika B, Widyaya VT, Nalam PC, Swasono YA, Ardhani R. Surface Modifications of High-Performance Polymer Polyetheretherketone (PEEK) to Improve Its Biological Performance in Dentistry. Polymers (Basel) 2022; 14:polym14245526. [PMID: 36559893 PMCID: PMC9787615 DOI: 10.3390/polym14245526] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Revised: 11/17/2022] [Accepted: 11/20/2022] [Indexed: 12/23/2022] Open
Abstract
This comprehensive review focuses on polyetheretherketone (PEEK), a synthetic thermoplastic polymer, for applications in dentistry. As a high-performance polymer, PEEK is intrinsically robust yet biocompatible, making it an ideal substitute for titanium-the current gold standard in dentistry. PEEK, however, is also inert due to its low surface energy and brings challenges when employed in dentistry. Inert PEEK often falls short of achieving a few critical requirements of clinical dental materials, such as adhesiveness, osseoconductivity, antibacterial properties, and resistance to tribocorrosion. This study aims to review these properties and explore the various surface modification strategies that enhance the performance of PEEK. Literatures searches were conducted on Google Scholar, Research Gate, and PubMed databases using PEEK, polyetheretherketone, osseointegration of PEEK, PEEK in dentistry, tribology of PEEK, surface modifications, dental applications, bonding strength, surface topography, adhesive in dentistry, and dental implant as keywords. Literature on the topics of surface modification to increase adhesiveness, tribology, and osseointegration of PEEK were included in the review. The unavailability of full texts was considered when excluding literature. Surface modifications via chemical strategies (such as sulfonation, plasma treatment, UV treatment, surface coating, surface polymerization, etc.) and/or physical approaches (such as sandblasting, laser treatment, accelerated neutral atom beam, layer-by-layer assembly, particle leaching, etc.) discussed in the literature are summarized and compared. Further, approaches such as the incorporation of bioactive materials, e.g., osteogenic agents, antibacterial agents, etc., to enhance the abovementioned desired properties are explored. This review presents surface modification as a critical and essential approach to enhance the biological performance of PEEK in dentistry by retaining its mechanical robustness.
Collapse
Affiliation(s)
- Bidhari Pidhatika
- Research Center for Polymer Technology, National Research and Innovation Agency, Republic of Indonesia PRTPL BRIN Indonesia, Serpong, Tangerang Selatan 15314, Indonesia
- Collaborative Research Center for Biomedical Scaffolds, National Research and Innovation Agency of the Republic Indonesia and Universitas Gadjah Mada, Jalan Denta No. 1, Sekip Utara, Yogyakarta 55281, Indonesia
| | - Vania Tanda Widyaya
- Research Center for Polymer Technology, National Research and Innovation Agency, Republic of Indonesia PRTPL BRIN Indonesia, Serpong, Tangerang Selatan 15314, Indonesia
| | - Prathima C. Nalam
- Department of Materials Design and Innovation, University at Buffalo, Buffalo, NY 14260-1900, USA
| | - Yogi Angga Swasono
- Research Center for Polymer Technology, National Research and Innovation Agency, Republic of Indonesia PRTPL BRIN Indonesia, Serpong, Tangerang Selatan 15314, Indonesia
| | - Retno Ardhani
- Department of Dental Biomedical Science, Faculty of Dentistry, Universitas Gadjah Mada, Jalan Denta No. 1, Sekip Utara, Yogyakarta 55281, Indonesia
- Correspondence:
| |
Collapse
|
19
|
Clinical report of six-month follow-up after cementing PEEK crown on molars. Sci Rep 2022; 12:19070. [PMID: 36351981 PMCID: PMC9646781 DOI: 10.1038/s41598-022-23458-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Accepted: 10/31/2022] [Indexed: 11/11/2022] Open
Abstract
We conducted a six-month clinical follow-up on computer-aided design/computer-aided manufacturing-fabricated molar polyetheretherketone PEEK crowns to investigate their therapeutic effect. Only the PEEK crowns were examined as our study focused on short-term clinical evaluation of the new PEEK material. Twenty-three cases of PEEK crowns placed on the molars of 20 subjects (7 males and 13 females, mean age: 60.6 ± 14.2 years) were included in the study. The evaluation items were the condition of the crowns at the time of cementation and after six months, patient satisfaction, masticatory ability, and occlusal force. Mann-Whitney U tests with a significance level of 5% were used to examine the difference in glucose concentration by masticatory ability, occlusal pressure, and occlusal force, with and without PEEK crowns. The occlusion, margin fit, and contact of all 23 cases at the time of cementing were good. Six months after cementation, there was no crown desorption, fracture or crack, and prosthodontics was not needed in the 22 cases (one patient dropped out). No wear of the dental antagonist was observed. Patient satisfaction was generally high. There was no significant difference in masticatory ability between the groups with and without PEEK crowns. The subject's occlusal force was within the normal range. PEEK crowns used on molars can replace metal crowns and hold promise for an appropriate and effective treatment.
Collapse
|
20
|
Saisho H, Marcolina G, Perucelli F, Goulart da Costa R, Machado de Souza E, Rached RN. Fracture strength, pull-out bond strength, and volume of luting agent of tooth-colored CAD-CAM post-and-cores. J Prosthet Dent 2022; 129:599-606. [PMID: 36127164 DOI: 10.1016/j.prosdent.2022.06.012] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Revised: 06/27/2022] [Accepted: 06/28/2022] [Indexed: 11/18/2022]
Abstract
STATEMENT OF PROBLEM Little is known about the fracture strength, retention, and adaptation of post-and-cores fabricated with novel tooth-colored materials by computer-aided design and computer-aided manufacturing (CAD-CAM). PURPOSE The purpose of this in vitro study was to investigate the fracture strength, pull-out bond strength (POBS), and volume of luting agent of endodontically treated premolars restored with post-and-cores milled from different CAD-CAM materials. MATERIAL AND METHODS Post spaces were prepared in 80 human premolars in which post-and-cores fabricated with polyetheretherketone (PK; Ceramill PEEK), nanohybrid composite resin (BB; Brava Block), polymer-infiltrated ceramic (EN; VITA Enamic), and fiber-reinforced epoxy resin (GF; Fiber Cad Post & Core) CAD-CAM materials were luted (n=20). All specimens were subjected to thermal aging (3000 cycles at 5 °C and 55 °C with a 20-second dwell time). Half of the specimens were subjected to mechanical fatigue (250 000 cycles at 5 Hz) before fracture strength testing, while the other half was submitted to POBS testing and volume of luting agent measurement. Fracture strength data were analyzed by 1-way ANOVA, while POBS and volume of luting agent data were submitted to Kruskal-Wallis followed by the Bonferroni-Dunn multiple comparison tests. The correlation between POBS and the volume of luting agent was determined by the Spearman test (α=.05). RESULTS POBS of GF was significantly higher than that for PK (P<.001); however, failure load (P=.160) and volume of luting agent (P=.390) values did not differ. EN showed the highest percentage of catastrophic failures (20%), while PK exhibited only core deformations. POBS and cement film volume were not significantly correlated (P>.05). CONCLUSIONS Different CAD-CAM materials did not influence the fracture strength and volume of luting agent of post-and-cores. Post-and-cores made with PEEK blocks showed lower bond strength to intracanal dentin than those made with fiber-reinforced epoxy resin blocks. No significant correlation was found between bond strength and the volume of luting agent.
Collapse
Affiliation(s)
- Hiromi Saisho
- Master's student, Graduate Program in Dentistry, School of Life Sciences, Pontifícia Universidade Católica do Paraná (PUCPR), Curitiba, PR, Brazil
| | - Gabriela Marcolina
- Predoctoral student, Dental Course, School of Life Sciences, Pontifícia Universidade Católica do Paraná (PUCPR), Curitiba, PR, Brazil
| | - Fabricio Perucelli
- Master's Student, Graduate Program in Dentistry, School of Life Sciences, Pontifícia Universidade Católica do Paraná (PUCPR), Curitiba, PR, Brazil
| | - Rogério Goulart da Costa
- Professor, Dental Prosthesis Course, Federal Institute of Paraná (IFPR), Curitiba, PR, Brazil; Professor, Graduate Program in Dentistry, School of Life Sciences, Pontifícia Universidade Católica do Paraná (PUCPR), Curitiba, PR, Brazil
| | - Evelise Machado de Souza
- Professor, Graduate Program in Dentistry, School of Life Sciences, Pontifícia Universidade Católica do Paraná (PUCPR), Curitiba, PR, Brazil
| | - Rodrigo Nunes Rached
- Professor, Graduate Program in Dentistry, School of Life Sciences, Pontifícia Universidade Católica do Paraná (PUCPR), Curitiba, PR, Brazil.
| |
Collapse
|
21
|
Wang B, Huang M, Dang P, Xie J, Zhang X, Yan X. PEEK in Fixed Dental Prostheses: Application and Adhesion Improvement. Polymers (Basel) 2022; 14:polym14122323. [PMID: 35745900 PMCID: PMC9228596 DOI: 10.3390/polym14122323] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2022] [Revised: 06/06/2022] [Accepted: 06/07/2022] [Indexed: 01/27/2023] Open
Abstract
Polyetheretherketone (PEEK) has been widely applied in fixed dental prostheses, comprising crowns, fixed partial dentures, and post-and-core. PEEK’s excellent mechanical properties facilitate better stress distribution than conventional materials, protecting the abutment teeth. However, the stiffness of PEEK is not sufficient, which can be improved via fiber reinforcement. PEEK is biocompatible. It is nonmutagenic, noncytotoxic, and nonallergenic. However, the chemical stability of PEEK is a double-edged sword. On the one hand, PEEK is nondegradable and intraoral corrosion is minimized. On the other hand, the inert surface makes adhesive bonding difficult. Numerous strategies for improving the adhesive properties of PEEK have been explored, including acid etching, plasma treatment, airborne particle abrasion, laser treatment, and adhesive systems.
Collapse
Affiliation(s)
- Biyao Wang
- Liaoning Provincial Key Laboratory of Oral Diseases, The VIP Department, School and Hospital of Stomatology, China Medical University, No. 117 North Street Nanjing Road, Shenyang 110002, China; (B.W.); (P.D.); (J.X.)
| | - Minghao Huang
- Liaoning Provincial Key Laboratory of Oral Diseases, Center of Implant Dentistry, School and Hospital of Stomatology, China Medical University, No. 117 North Street Nanjing Road, Shenyang 110002, China;
| | - Pengrui Dang
- Liaoning Provincial Key Laboratory of Oral Diseases, The VIP Department, School and Hospital of Stomatology, China Medical University, No. 117 North Street Nanjing Road, Shenyang 110002, China; (B.W.); (P.D.); (J.X.)
| | - Jiahui Xie
- Liaoning Provincial Key Laboratory of Oral Diseases, The VIP Department, School and Hospital of Stomatology, China Medical University, No. 117 North Street Nanjing Road, Shenyang 110002, China; (B.W.); (P.D.); (J.X.)
| | - Xinwen Zhang
- Liaoning Provincial Key Laboratory of Oral Diseases, Center of Implant Dentistry, School and Hospital of Stomatology, China Medical University, No. 117 North Street Nanjing Road, Shenyang 110002, China;
- Correspondence: (X.Z.); (X.Y.); Tel.: +86-024-31927731 (X.Z.); +86-024-31927715 (X.Y.)
| | - Xu Yan
- Liaoning Provincial Key Laboratory of Oral Diseases, The VIP Department, School and Hospital of Stomatology, China Medical University, No. 117 North Street Nanjing Road, Shenyang 110002, China; (B.W.); (P.D.); (J.X.)
- Correspondence: (X.Z.); (X.Y.); Tel.: +86-024-31927731 (X.Z.); +86-024-31927715 (X.Y.)
| |
Collapse
|
22
|
Karaokutan I, Cinel Şahin S, Sagesen HLE. Impact of Resin Cement and Adhesive Systems on the Bond Strength of Polyetheretherketone Dental Restorations. MEANDROS MEDICAL AND DENTAL JOURNAL 2022. [DOI: 10.4274/meandros.galenos.2021.55823] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
23
|
Binhasan M, Alhamdan MM, Al-Aali KA, Vohra F, Abduljabbar T. Shear bond characteristics and surface roughness of poly-ether-ether ketone treated with contemporary surface treatment regimes bonded to composite resin. Photodiagnosis Photodyn Ther 2022; 38:102765. [PMID: 35182780 DOI: 10.1016/j.pdpdt.2022.102765] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2022] [Revised: 02/10/2022] [Accepted: 02/15/2022] [Indexed: 11/26/2022]
Abstract
AIM To evaluate and compare the influence of contemporary surface treatments of air abrasions, sulfuric acid, and Photodynamic therapy (PDT) on the adhesive bonding and surface roughness of Poly-ether-ether-ketone (PEEK) bonded to resin composite. MATERIAL AND METHODS One hundred and fifty PEEK (disc-shaped) specimens of 10 mm diameter and 2mm thickness were prepared. Specimens were subjected to the following surface treatments, Control (no treatment), PDT, air abrasion using Alumina particles (110 μm) (AA-AP), Sulfuric acid (SA), and air abrasion using diamond particles (10-20 μm) AA-DP. Surface roughness (Ra) of treated samples were evaluated using surface profilometer. Universal testing machine was used to evaluate shear bond strength after composite resin build-up. Stereomicroscope was utilized for failure analysis of de-bonded samples of all five groups. Statistical analysis was performed utilizing one-way analysis of variance (ANOVA) to measure means and standard deviations of SBS among studied groups and the means of SBS were paralleled by Tukey multiple comparison tests (p>0.05). RESULTS The highest SBS was observed by 98% SA (19.25 ± 0.68 MPa). While specimen treated with PDT (11.69 ± 0.12 MPa) showed the lowest SBS. PEEK surface, treated with PDT and AA-DP demonstrated comparable SBS (p>0.05). PEEK when pretreated with 98% SA (2.658 ± 0.658μm) exhibited a significantly higher Ra value as compared to other surface-treated groups (p< 0.05). CONCLUSION PEEK surface treated with SA showed the highest SBS and surface roughness compared to other groups. Surface roughness of PEEK treated with PDT, AA-AP, and AA-DP demonstrated no difference in Ra. PEEK surface treatment technique should be further investigated to develop reliable adhesive resin bonding.
Collapse
Affiliation(s)
- Mashael Binhasan
- Department of Restorative Dentistry, Division of Operative Dentistry College of Dentistry, King Saud University.
| | - Mai M Alhamdan
- Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University. Riyadh, Saudi Arabia.
| | - Khulud A Al-Aali
- Department Of Clinical Dental Sciences, College of Dentistry, Princess Nourah Bint Abdulrahman University.
| | - Fahim Vohra
- Department of Prosthetic Dental Science, College of Dentistry, King Saud University Riyadh 11545, Saudi Arabia.
| | - Tariq Abduljabbar
- Department of Prosthetic Dental Science, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia.
| |
Collapse
|
24
|
Parkar U, Dugal R, Madanshetty P, Devadiga T, Khan AS, Godil A. Assessment of different surface treatments and shear bond characteristics of poly-ether-ether-ketone: An in vitro SEM analysis. J Indian Prosthodont Soc 2021; 21:412-419. [PMID: 34810370 PMCID: PMC8617443 DOI: 10.4103/jips.jips_199_21] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/04/2022] Open
Abstract
Aim: The aim of this study is to assess the surface roughness and shear bond characteristics of pol-ether-ether-ketone after different surface treatments. Setting and Design: An in vitro, prospective. Materials and Methods: One hundred and twenty disc-shaped samples of 10 mm diameter and 2 mm thickness were milled and subjected to following surface treatments: 110 μm alumina particles, 98% concentrated sulfuric acid, and 10–20 μm synthetic diamond particles. Surface characteristics of treated sample were studied under SEM with ×500 and ×1000 magnification. Shear bond strength (SBS) with composite resin discs embedded in acrylic blocks after luting with self-etch resin cement and resin-modified glass ionomer cement (RMGIC) was evaluated using the universal testing machine (Instron®, Massachusetts U. S. A). Statistical Analysis Used: The data collected were evaluated using the Analysis of variance and Tukey's honest significant difference post hoc test. Results: Highest SBS and SR were noted with self-etch resin cement in the given order: 98% sulfuric acid (2.106 ± 0.186 μm), followed by alumina particles (1.706 ± 0.160 μm) and synthetic diamond particles (1.101 ± 0.167 μm). Conclusion: The SBS of self-etch resin cement was higher compared to RMGIC for all three surface treatments done on test samples. Hundred percent samples treated by all three surface treatment methods showed mixed type of failure.
Collapse
Affiliation(s)
- Umair Parkar
- Department of Prosthodontics, M. A. Rangoonwala College of Dental Science and Research Centre, Pune, Maharashtra, India
| | - Ramandeep Dugal
- Department of Prosthodontics, M. A. Rangoonwala College of Dental Science and Research Centre, Pune, Maharashtra, India
| | - Pallavi Madanshetty
- Department of Prosthodontics, Rural Dental College, PMT PIMS, Loni, Uttar Pradesh, India
| | - Trupti Devadiga
- Department of Prosthodontics, M. A. Rangoonwala College of Dental Science and Research Centre, Pune, Maharashtra, India
| | - Abid Sharifullah Khan
- Department of Prosthodontics, M. A. Rangoonwala College of Dental Science and Research Centre, Pune, Maharashtra, India
| | - Aamir Godil
- Department of Prosthodontics, M. A. Rangoonwala College of Dental Science and Research Centre, Pune, Maharashtra, India
| |
Collapse
|
25
|
Barragán-Paredes MA, Mosquera-Victoria I, Viveros-Rebolledo CA, Rodríguez-Paz ML, Muñoz-Velez MF, Valencia - Llano CH. Comparison of the Mechanical Properties of Temporary Abutments Made of Polyetheretherketone and Photopolymeric Resin. Open Dent J 2021. [DOI: 10.2174/1874210602115010512] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Background:
Provisional abutments are widely used in the rehabilitation of dental implants as it allows the use of a provisional crown in order to restore patient aesthetics while the final restoration is being carried out; most of the temporary abutments available on the market are made of titanium alloygrade V (type Ti-6Al-4Va) and polyetheretherketone (PEEK), a material that exhibits very low adhesion to polymethylmethacrylate (PMMA).
Objective:
This research is aimed to compare the mechanical properties of commercially available PEEK abutments and abutments made using an additive technique with photopolymeric resin.
Methods:
Eighteen commercial temporary abutments manufactured in PEEK and eighteen experimental abutments manufactured by 3D printing using photopolymeric resin were used. The two groups of abutments were subjected to compression, bending and adhesion tests using six abutments of each type by test. Statistical analysis was performed with STATA 14 software. The data were analyzed by means of the Wilcoxon Mann-Whitney test, as these were two independent samples of reduced size. Values lower than (p <0.05) were considered statistically significant in all tests and rejected the null hypothesis of equality between the group medians.
Conclusion:
The results indicate that it is possible to make abutments with good mechanical properties in photopolymeric resin (CLEAR FLGP04) using additive techniques to be used as temporary abutments.
Collapse
|
26
|
Özarslan M, Büyükkaplan UŞ, Özarslan MM. Comparison of the fracture strength of endodontically treated teeth restored with polyether ether ketone, zirconia and glass-fibre post-core systems. Int J Clin Pract 2021; 75:e14440. [PMID: 34096673 DOI: 10.1111/ijcp.14440] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Accepted: 05/25/2021] [Indexed: 11/28/2022] Open
Abstract
PURPOSE This study aimed to compare the fracture resistance and fracture mode of maxillary central incisors restored with four different sizes and three different post-core systems. MATERIALS AND METHODS One hundred and twenty maxillary incisors were endodontically treated and randomly divided into three groups (12 subgroups). Post cavities for the narrow subgroups were prepared with 1.4-mm-diameter drills in lengths of 7.5 mm (SN) and 10 mm (LN). Post cavities for the wide subgroups were prepared with 1.6-mm-diameter drills in lengths of 7.5 mm (SW) and 10 mm (LW) (n = 10). Group F was restored with glass-fibre post and composite resin core, Group P was restored with custom PEEK post-core and Group Z was restored with custom zirconia post-core. All posts were cemented with a dual-cure resin cement. Zirconia copings were cemented. Specimens were loaded on the palatal surface with a universal testing machine, and the fracture strengths of the teeth were statistically analysed using ANOVA and post hoc Tukey tests. RESULTS Statistically significant differences existed between the fracture strengths of the post materials. The highest fracture strength was in Group F, and the lowest was in Group P. Evaluation of the fracture strengths of the post lengths and diameters demonstrated that the short-narrow group of Group Z had the lowest fracture strength (P < .05). The long-wide group of Group F showed the highest fracture resistance. In Group P, no statistically significant difference existed between the post-cores of different dimensions (P > .05). Irreparable fractures were observed mostly in Group Z, and decementation was more common in Group P. CONCLUSIONS PEEK post-cores showed sufficient fracture strength for the anterior region, similar to the other two post-core materials. PEEK post-cores showed more decementation and repairable fractures at lower forces, while restoration failure was mostly catastrophic for glass-fibre and zirconia posts.
Collapse
Affiliation(s)
- Merve Özarslan
- Department of Prosthetic Dentistry, Faculty of Dentistry, Akdeniz University, Antalya, Turkey
| | | | - Mehmet Mustafa Özarslan
- Department of Prosthetic Dentistry, Faculty of Dentistry, Akdeniz University, Antalya, Turkey
| |
Collapse
|
27
|
Ozkan Ata S, Akay C, Ata N. Evaluation of bond strength of polyether ether ketone (PEEK) to composite resin on hypobaric and hyperbaric conditions. INT J POLYM MATER PO 2021. [DOI: 10.1080/00914037.2021.1960343] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Affiliation(s)
- Secil Ozkan Ata
- Department of Prosthodontics, Oral and Dental Health Hospital, Eskisehir, Turkey
| | - Canan Akay
- Department of Prosthodontics, Faculty of Dentistry, Eskişehir Osmangazi University, Eskisehir, Turkey
- Advanced Material Technologies Application and Research Center, Osmangazi University, Eskisehir, Turkey
- Translational Medicine Research and Clinical Center, Osmangazi University, Eskisehir, Turkey
| | - Nazim Ata
- Aeromedical Research and Training Center, Eskisehir, Turkey
| |
Collapse
|
28
|
On the synergistic effect of sulfonic functionalization and acidic adhesive conditioning to enhance the adhesion of PEEK to resin-matrix composites. Dent Mater 2021; 37:741-754. [PMID: 33589269 DOI: 10.1016/j.dental.2021.01.017] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2020] [Revised: 08/02/2020] [Accepted: 01/20/2021] [Indexed: 11/22/2022]
Abstract
OBJECTIVE The objective of this study was to evaluate the combined effect of the sulfuric acid etching and an acidic adhesive conditioning on the shear bond strength of PEEK to a resin-matrix composite. MATERIALS AND METHODS Forty PEEK specimens were assigned randomly to 4 groups for H2SO4 etching followed by universal adhesive (pH at 2.5) conditioning for 0, 1, 3, and 5 min. Thirty PEEK specimens were divided into 3 groups for only acidic adhesive conditioning for 0, 1, 3, and 5 min. After the light-curing of the adhesive, a nanohybrid resin composite was applied onto the surfaces and then light-cured following the manufacturer`s guidelines. All specimens were stored in distilled water at 37 °C for 24 h mechanical testing. Shear bond strength tests were performed using a universal testing machine. Surfaces were analyzed by SEM, light interferometry, FTIR, and liquid contact angle measurement. Statistical analysis was performed by one-way ANOVA and Tukey's post hoc tests (p < 0.05). RESULTS No adhesion was achieved between untreated PEEK a resin-matrix composite, regardless of the adhesive conditioning time points. Shear bond strength of H2SO4-etched PEEK to resin-matrix composite increased with time (0 mmin. 4.95 ± 2.86 MPa < 1 min: 9.35 ± 2.26 MPa < 3 min: 17.84 ± 2.82 MPa < 5 min: 21.43 ± 5.00 MPa). SEM images revealed a significant modification of PEEK surface topography after the H2SO4 etching. SIGNIFICANCE The acidic adhesive was unable to modify the untreated PEEK surface to establish an effective adhesion although a synergistic effect was noticed when the universal (acidic) adhesive was applied over a H2SO4-etched PEEK surface, thus improving the PEEK to resin-matrix composite adhesion.
Collapse
|
29
|
Dede DÖ, Küçükekenci AS, Kahveci Ç. Influence of chairside surface treatments on the shear bond strength of PEKK polymer to veneering resin materials: An in vitro study. J Prosthet Dent 2021; 125:703.e1-703.e7. [PMID: 33551138 DOI: 10.1016/j.prosdent.2020.10.031] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2020] [Revised: 10/20/2020] [Accepted: 10/20/2020] [Indexed: 11/17/2022]
Abstract
STATEMENT OF PROBLEM High-performance thermoplastics have been adopted as an alternative restorative material to metal or ceramics. However, a straightforward surface modification process to provide a durable bond strength between the polymer and the veneering material is lacking. PURPOSE The purpose of this in vitro study was to evaluate the shear bond strength (SBS) of different veneering resin materials to polyetherketoneketone (PEKK) after different surface treatments. MATERIAL AND METHODS Rectangular (7×7×2 mm) PEKK specimens (N=120) were randomly allocated to the following 6 groups (n=20): untreated (Cnt); nonthermal plasma (NTP) treated; tribochemical silica airborne-particle abrasion with 30-μm silica-modified Al2O3 (Tbc); abraded with a coarse-grit diamond rotary instrument (Ab); tribochemical silica airborne-particle abrasion + plasma treated (Tbc_NTP); abraded + plasma treated (Ab_NTP). After a bonding agent (PEKK Bond) was applied to the specimens, each group was divided into 2 subgroups according to the applied veneering resin materials: polymethylmethacrylate (PMMA) and nanohybrid composite resin (NHC, n=10). The specimens were stored in water for 24 hours at 37 °C and subjected to the SBS test by using a universal testing machine, and failure modes were evaluated using a stereomicroscope. Two-way analysis of variance (ANOVA) was performed followed by the Tukey honestly significant difference (HSD) test to statistically analyze the data (α=.05). RESULTS The 2-way ANOVA showed that surface treatment methods, veneering material, and their interactions were significantly different on the SBS values (P<.001). The highest SBS values were determined for the Tbc and Tbc_NTP treatment groups not only for PMMA (10.71 to 11.63 MPa) but also for NHC (19.80 to 20.60 MPa) veneering resin materials (P<.05). CONCLUSIONS The bonding capacity of PEKK to the PMMA and NHC veneering resin materials can be significantly improved by using tribochemical silica airborne-particle abrasion alone or with nonthermal plasma surface treatment techniques. Furthermore, using NHC veneering resin material is recommended over PMMA.
Collapse
Affiliation(s)
- Doğu Ömür Dede
- Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Ordu University, Ordu, Turkey.
| | - Ahmet Serkan Küçükekenci
- Assistant Professor, Department of Prosthodontics, Faculty of Dentistry, Ordu University, Ordu, Turkey
| | - Çiğdem Kahveci
- Research Assistant, Department of Prosthodontics, Faculty of Dentistry, Ordu University, Ordu, Turkey
| |
Collapse
|
30
|
Teng R, Meng Y, Zhao X, Liu J, Ding R, Cheng Y, Zhang Y, Zhang Y, Pei D, Li A. Combination of Polydopamine Coating and Plasma Pretreatment to Improve Bond Ability Between PEEK and Primary Teeth. Front Bioeng Biotechnol 2021; 8:630094. [PMID: 33585424 PMCID: PMC7880054 DOI: 10.3389/fbioe.2020.630094] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2020] [Accepted: 12/21/2020] [Indexed: 12/14/2022] Open
Abstract
Preformed crowns are preferred to reduce the failure risk of restoration of primary teeth, but some drawback of conventional material is still a main barrier for their clinical use. Polyether etherketone (PEEK), a tooth colored, high-performance thermoplastic polymer, has been recognized as a promising alternative to manufacture the restoration of primary teeth. However, the hydrophobic surface and low surface energy of PEEK make it hard to establish a strong and durable adhesion. In this study, we have evaluated a modification method of polydopamine (PDA) coating with plasma pretreatment for the PEEK films by physical and chemical characterization, bonding properties, and biocompatibility. The surface properties of PEEK were well-characterized by scanning electron microscope (SEM) and X-ray photoelectron spectroscopy (XPS). The adhesive strength of the PEEK films was greatly improved without significant reduction of the proliferation rate of human gingival fibroblast cells in MTT and Live/Dead assays. Therefore, PDA coating with plasma pretreatment may give a new solution for effective clinical application of PEEK in primary performed crowns.
Collapse
Affiliation(s)
- Rui Teng
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, China
| | - Yuchen Meng
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, China
| | - Xiaodan Zhao
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, China
| | - Jie Liu
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, China
| | - Rui Ding
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, China
| | - Yilong Cheng
- School of Chemistry, Xi'an Jiaotong University, Xi'an, China
| | - Yunhe Zhang
- Engineering Research Center of Super Engineering Plastics, Ministry of Education, College of Chemistry, Jilin University, Changchun, China
| | - Yanfeng Zhang
- School of Chemistry, Xi'an Jiaotong University, Xi'an, China
| | - Dandan Pei
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, China
| | - Ang Li
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, China.,Department of Periodontology, College of Stomatology, Xi'an Jiaotong University, Xi'an, China
| |
Collapse
|
31
|
Attia MA, Shokry TE, Abdel-Aziz M. Effect of different surface treatments on the bond strength of milled polyetheretherketone posts. J Prosthet Dent 2021; 127:866-874. [PMID: 33495042 DOI: 10.1016/j.prosdent.2020.08.033] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2020] [Revised: 08/08/2020] [Accepted: 08/10/2020] [Indexed: 12/01/2022]
Abstract
STATEMENT OF PROBLEM Polyetheretherketone (PEEK) can be used as a framework material for removable and fixed dental prostheses. However, information about the use of PEEK as a post-and-core restoration is scarce. PURPOSE The purpose of this in vitro study was to evaluate the effect of different surface treatments on the push-out bond strength of milled polyetheretherketone posts to resin cement. MATERIAL AND METHODS Sixty intact human maxillary central incisors were selected and endodontically treated, and standardized post spaces were prepared. Sixty PEEK posts were milled from a prefabricated PEEK blank by using a computer-aided design and computer-aided manufacturing (CAD-CAM) system and divided into 3 groups (n=15) according to the surface treatment: acid etching by using 98% sulfuric acid (AE); airborne-particle abrasion by using 50-μm Al2O3 (AA); nonthermal plasma treatment (NTP); in addition, PEEK posts (n=15) received no treatment (NT) and served as a control. All posts were bonded by using a self-adhesive resin cement. Three sections (coronal, middle, and apical) were obtained for each specimen. Push-out bond strength measurements (MPa) for each section were recorded by using a universal testing machine at a crosshead speed of 0.5 mm/min until failure occurred. The post-cement interfaces and failure modes were evaluated by using scanning electron microscopy. The data obtained were statistically analyzed by using 1-way ANOVA and the pair-wise Tukey (HSD) test to study the difference between group mean values (α=.05). RESULTS The overall mean ±standard deviation of the push-out bond strength was 11 ±2 MPa for AE group, 6 ±1 MPa for AA group, 5 ±1 MPa for NTP group, and 3 ±1 MPa for NT group. A statistically significant difference was found among all groups subjected to different surface treatments as indicated by the ANOVA test (P<.001). The pair-wise Tukey honestly significant difference (HSD) test showed a significant difference among the AE group and all groups (P<.001); however, no significant difference was observed between the AA and NTP groups (P>.05). Moreover, a significant difference was observed among all root sections (P<.001). CONCLUSIONS Surface treatment of PEEK posts with 98% sulfuric acid for 60 seconds showed significantly higher bond strength values than those in other groups. The bond strength of PEEK posts to resin cement was significantly higher in the coronal section than that in other sections.
Collapse
Affiliation(s)
- Mazen A Attia
- Associate Professor, Department of Fixed Prosthodontics, Faculty of Dentistry, Beni-Suef University, Beni-Suef, Egypt.
| | - Tamer E Shokry
- Professor, Department of Fixed Prosthodontics, Faculty of Dental Medicine, Al-Azhar University, Cairo, Egypt
| | - Mohamed Abdel-Aziz
- Associate Professor, Department of Fixed Prosthodontics, Faculty of Dental Surgery, Ahram Canadian University, Cairo, Egypt
| |
Collapse
|
32
|
LÜmkemann N, Eichberger M, Murphy RJ, Stawarczyk B. Suitability of the new Aryl-Ketone-Polymer indicated for removable partial dentures: Analysis of elastic properties and bond strength to denture resin. Dent Mater J 2020; 39:539-546. [PMID: 32092725 DOI: 10.4012/dmj.2019-125] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Elastic properties of Aryl-Ketone-Polymer (UAKP) and tensile bond strength (TBS) to denture resin (PalaXpress) were tested. Indentation modulus (EIT) and indentation hardness (HIT) were measured via Martens hardness (n=10 specimens) with 4.2±0.6 kN/mm2 and 261±8 N/mm2 respectively. TBS was tested in dependence of different adhesives (visio.link (VL), Adhese Universal (AU), All-Bond Universal (ABU), CLEARFIL UNIVERSAL BOND (CUB), G-Premio BOND (GPB), iBOND Universal (IBU), ONE COAT 7 UNIVERSAL (OCU), Scotchbond Universal (SBU) and without adhesive (CG), n=18/group) and the application of opaquer (n=9/group) after thermocycling (5°C/55°C, 10,000×). TBS was affected by the adhesive (η (P2=0.715, p<0.001) followed by the opaquer (ηP2=0.335, p<0.001). VL and CG showed highest TBS followed by AU and ABU. IBU and GPB resulted in lowest TBS. Opaquer increased TBS for all adhesives (p<0.05), except VL and CG (p<0.258). Elastic properties are well-suited for the indication of removable partial dentures. Bonding to denture resin is no limiting factor.
Collapse
Affiliation(s)
- Nina LÜmkemann
- Department of Prosthetic Dentistry, University Hospital, Ludwig-Maximilians-University Munich
| | - Marlis Eichberger
- Department of Prosthetic Dentistry, University Hospital, Ludwig-Maximilians-University Munich
| | | | - Bogna Stawarczyk
- Department of Prosthetic Dentistry, University Hospital, Ludwig-Maximilians-University Munich
| |
Collapse
|
33
|
Surface characterization and bonding properties of milled polyetheretherketone dental posts. Odontology 2020; 108:596-606. [PMID: 31965408 DOI: 10.1007/s10266-020-00484-1] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2019] [Accepted: 01/05/2020] [Indexed: 10/25/2022]
Abstract
PEEK has been used in many dental applications except intra-radicular post. The aim of this study is to test polyetheretherketone (PEEK) as a dental post material through tensile bond strength (TBS) and surface roughness (SR), and to compare it with glass-fiber and cast-metal posts. Thus, 60 human maxillary central incisors with a single root were endodontically treated and divided into three groups (n = 20) according to the type of post (Group P: PEEK, Group F: Glass-fiber, Group M: Cast-metal). Appropriate surface treatment was employed for each group and SR was determined by a three-dimensional non-contact profilometer before cementation. All posts were luted to the canal dentin using self-etch resin cement (Panavia F2.0). Pull-out test was performed on a universal testing machine at a speed of 0.5 mm/min crosshead speed until failure, and TBS were calculated. One-way ANOVA, Tukey's HSD, and Pearson chi-squared tests were performed for statistical analyses (α = 0.05). According to the results, group F demonstrated the highest SR (2.93 ± 0.18 µm) and lowest TBS values (10.05 ± 0.53 MPa), while group P exhibited lowest SR (1.37 ± 0.11 µm) and highest TBS values (14.33 ± 0.58 MPa) (p < 0.001). No significant differences in failure modes were identified among groups, mostly adhesive (p = 0.243). As conclusion, PEEK may be a reliable and contemporary option for dental post systems when used with appropriate surface treatment and luting agent. This high-performance polymer may be a novel candidate as a contemporary dental post system due to its superior mechanical, chemical, thermal, and esthetical properties with low risk of fracture.
Collapse
|
34
|
Three-Dimensionally-Printed Polyether-Ether-Ketone Implant with a Cross-Linked Structure and Acid-Etched Microporous Surface Promotes Integration with Soft Tissue. Int J Mol Sci 2019; 20:ijms20153811. [PMID: 31382697 PMCID: PMC6695707 DOI: 10.3390/ijms20153811] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2019] [Revised: 07/25/2019] [Accepted: 08/02/2019] [Indexed: 12/13/2022] Open
Abstract
Polyether-ether-ketone (peek) is one of the most common materials used for load-bearing orthopedic devices owing to its radiolucency and favorable mechanical properties. However, current smooth-surfaced peek implants can lead to fibrous capsule formation. To overcome this issue, here, peek specimens with well-defined internal cross-linked structures (macropore diameters of 1.0–2.0 mm) were fabricated using a three-dimensional (3D) printer, and an acid-etched microporous surface was achieved using injection-molding technology. The cell adhesion properties of smooth and microporous peek specimens was compared in vitro through a scanning electron microscope (SEM), and the soft tissue responses to the both microporous and cross-linked structure of different groups were determined in vivo using a New Zealand white rabbit model, and examined through histologic staining and separating test. The results showed that the acid-etched microporous surface promoted human skin fibroblasts (HSF) adherence, while internal cross-linked structure improved the ability of the peek specimen to form a mechanical combination with soft tissue, especially with the 1.5 mm porous specimen. The peek specimens with both the internal cross-linked structure and external acid-etched microporous surface could effectively promote the close integration of soft tissue and prevent formation of fibrous capsules, demonstrating the potential for clinical application in surgical repair.
Collapse
|
35
|
Kurahashi K, Matsuda T, Ishida Y, Ichikawa T. Effect of Surface Treatments on Shear Bond Strength of Polyetheretherketone to Autopolymerizing Resin. Dent J (Basel) 2019; 7:dj7030082. [PMID: 31374927 PMCID: PMC6784460 DOI: 10.3390/dj7030082] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2019] [Revised: 07/24/2019] [Accepted: 07/24/2019] [Indexed: 11/16/2022] Open
Abstract
These days, new prosthodontic materials are appearing with the development of digitalization. Among these, the use of polyetheretherketone (PEEK) as the clasp of removable partial dentures has been proposed. The adhesive strength between the PEEK and acrylic resin influences the probability of denture fracture. To investigate the effect of PEEK surface treatments on the shear bond strength to acrylic resin, five surface treatment conditions of PEEK were analyzed: 1. no treatment; 2. ceramic primer application; 3. Al2O3 sandblasting; 4. Rocatec; and 5. Rocatec with ceramic primer application, comparing with a metal primer-treated Co-Cr alloy. Two kinds of autopolymerizing resin (Unifast II and Palapress Vario) were used as bonding materials. The specimens were evaluated to determine the bond strength. Rocatec treatment with ceramic primer application yielded the highest bond strengths (12.71 MPa and 15.32 MPa, respectively, for Unifast II and Palapress Vario). When compared to a metal primer-treated Co-Cr alloy, the bond strength of PEEK to Unifast II was similar, whereas it was about 60% of that to Palapress Vario. Rocatec treatment, combined with ceramic primer, showed the highest bond strength of PEEK to acrylic resin. Treatment of PEEK will enable its use as the clasp of removable dentures and the fixation of PEEK prostheses.
Collapse
Affiliation(s)
- Kosuke Kurahashi
- Department of Prosthodontics & Oral rehabilitation, Tokushima University, Graduate School of Biomedical Sciences, 3-18-15 Kuramoto, Tokushima 770-8504, Japan
| | - Takashi Matsuda
- Department of Prosthodontics & Oral rehabilitation, Tokushima University, Graduate School of Biomedical Sciences, 3-18-15 Kuramoto, Tokushima 770-8504, Japan
| | - Yuichi Ishida
- Department of Prosthodontics & Oral rehabilitation, Tokushima University, Graduate School of Biomedical Sciences, 3-18-15 Kuramoto, Tokushima 770-8504, Japan
| | - Tetsuo Ichikawa
- Department of Prosthodontics & Oral rehabilitation, Tokushima University, Graduate School of Biomedical Sciences, 3-18-15 Kuramoto, Tokushima 770-8504, Japan.
| |
Collapse
|
36
|
Rikitoku S, Otake S, Nozaki K, Yoshida K, Miura H. Influence of SiO 2 content of polyetheretherketone (PEEK) on flexural properties and tensile bond strength to resin cement. Dent Mater J 2019; 38:464-470. [PMID: 30971651 DOI: 10.4012/dmj.2018-234] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
In the present study, the influence of the SiO2 content of polyetheretherketone (PEEK) on the bonding between PEEK and resin cement, and the corresponding mechanical properties, were evaluated. Three experimental PEEK samples with varying amounts of SiO2, and PEEK containing 20 wt% of TiO2 (DK), were investigated. The tensile bond strength (TBS) was evaluated before and after 10,000 thermal cycles, upon polishing, sandblasting, and conditioning of the specimens with BONDMER lightless containing a silane coupling agent, and bonded with ESTECEM II. The crystallinity, flexural modulus, and flexural strength were determined after 10,000 thermal cycles. TBS values were analyzed by two-way ANOVA and a t-test with Bonferroni correction (α<0.05), while the crystallinity, flexural modulus, and flexural strength were analyzed with one-way ANOVA followed by a t-test with Bonferroni correction (α<0.05). The TBS improved with increasing SiO2 content in PEEK; moreover, DK and the sample with 40 wt% SiO2 exhibited the highest flexural strength.
Collapse
Affiliation(s)
- Shiro Rikitoku
- Department of Fixed Prosthodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU)
| | - Shiho Otake
- Department of Fixed Prosthodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU)
| | - Kosuke Nozaki
- Department of Material Biofunctions, Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University (TMDU)
| | - Keiichi Yoshida
- Department of Fixed Prosthodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU)
| | - Hiroyuki Miura
- Department of Fixed Prosthodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU)
| |
Collapse
|
37
|
Tsuka H, Morita K, Kato K, Kimura H, Abekura H, Hirata I, Kato K, Tsuga K. Effect of laser groove treatment on shear bond strength of resin-based luting agent to polyetheretherketone (PEEK). J Prosthodont Res 2018; 63:52-57. [PMID: 30220621 DOI: 10.1016/j.jpor.2018.08.001] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2017] [Revised: 08/03/2018] [Accepted: 08/05/2018] [Indexed: 11/18/2022]
Abstract
PURPOSE The mechanical properties of polyetheretherketone (PEEK) are ideally suited for fixed dental prostheses. However, PEEK typically has low adhesion strength to resin-based luting agent. This study assessed the shear bond strength between laser groove treated PEEK and resin-based luting agent. METHODS A total of 230 specimens were randomly divided into five groups (n=46): no-treatment, air abrasion treatment, 100μm-deep, 150μm-deep, and 200μm-deep laser groove treatments. The surface roughness was measured, scanning electron microscopy was used to observe the specimen surfaces, and X-ray photoelectron spectroscopy (XPS) was used to analyze the surfaces. Each group was divided into four resin-based luting agent subgroups: Panavia V5, RelyX Ultimate Resin Cement, G-CEM Link Force, and Super-Bond C&B. After the resin-based luting agent was bonded to the specimens, the bond strength was measured using shear tests and the failure modes were assessed by stereomicroscopy. The surfaces were also observed by scanning electron microscopy (SEM) after the shear bond strength measurements. The data were statistically analyzed using a two-way analysis of variance and Tukey's honest significant difference test (α=0.05). RESULTS The PEEK surface after laser groove treatment groups exhibited the highest mean Ra values. In the XPS analysis, the laser treated PEEK surface exhibited an effective surface composition for bonding with resin-based luting agent. The shear bond strengths for the laser groove treated samples were significantly higher (p<0.05) than those of the no-treatment and air abrasion treatment groups. CONCLUSIONS The shear bond strength between PEEK and resin-based luting agent was substantially improved by laser groove treatment.
Collapse
Affiliation(s)
- Hiroki Tsuka
- Department of Advanced Prosthodontics, Applied Life Sciences, Institute of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan.
| | - Koji Morita
- Department of Advanced Prosthodontics, Applied Life Sciences, Institute of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| | - Kan Kato
- Department of Advanced Prosthodontics, Applied Life Sciences, Institute of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| | - Hitomi Kimura
- Department of Advanced Prosthodontics, Applied Life Sciences, Institute of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| | - Hitoshi Abekura
- Department of Advanced Prosthodontics, Applied Life Sciences, Institute of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| | - Isao Hirata
- Department of Biomaterials, Applied Life Sciences, Institute of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| | - Koichi Kato
- Department of Biomaterials, Applied Life Sciences, Institute of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| | - Kazuhiro Tsuga
- Department of Advanced Prosthodontics, Applied Life Sciences, Institute of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| |
Collapse
|