1
|
Kim B, Kim Y, Lee Y, Oh J, Jung Y, Koh WG, Chung JJ. Reactive Oxygen Species Suppressive Kraft Lignin-Gelatin Antioxidant Hydrogels for Chronic Wound Repair. Macromol Biosci 2022; 22:e2200234. [PMID: 36067493 DOI: 10.1002/mabi.202200234] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2022] [Revised: 08/05/2022] [Indexed: 12/25/2022]
Abstract
Chronic wound is difficult to repair because the normal wound healing mechanism is inhibited by the continuous inflammatory response. The delayed inflammatory responses generate high level of reactive oxygen species (ROS) at the wound sites, which leads to a longer inflammatory phase and induces a vicious cycle that interferes with the normal wound healing process. Therefore, ROS scavenging is an important factor for chronic wound healing. In this study, antioxidant hydrogel is developed by cross-linking kraft lignin, an antioxidant agent, and gelatin (Klig-Gel). Klig-Gel hydrogel is fabricated via ring opening reaction with epichlorohydrin as a cross-linker. High ROS scavenging activities are confirmed by various antioxidant evaluations, and in vitro natural antioxidant expression tests show reduction of oxidative stress. Mechanical properties of Klig-Gel hydrogel are tailorable by introducing different amount of kraft lignin to the hydrogel system. Biocompatibility is confirmed regardless of the kraft lignin content. Klig-Gel hydrogel is a promising ROS scavenging material that can be applied in various chronic wound healing applications.
Collapse
Affiliation(s)
- Byulhana Kim
- Transdisciplinary Department of Medicine and Advanced Technology, Seoul National University Hospital, Seoul, 03080, Republic of Korea.,Department of Chemical and Biomolecular Engineering, College of Engineering, Yonsei University, Seoul, 03722, Republic of Korea
| | - Young Kim
- Transdisciplinary Department of Medicine and Advanced Technology, Seoul National University Hospital, Seoul, 03080, Republic of Korea.,Program in Nanoscience and Technology, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, 08826, Republic of Korea
| | - Yoonho Lee
- Transdisciplinary Department of Medicine and Advanced Technology, Seoul National University Hospital, Seoul, 03080, Republic of Korea
| | - Joomin Oh
- Transdisciplinary Department of Medicine and Advanced Technology, Seoul National University Hospital, Seoul, 03080, Republic of Korea
| | - Youngmee Jung
- Biomaterials Research Center, Biomedical Research Division, Korea Institute of Science and Technology, Seoul, 02792, Republic of Korea.,School of Electrical and Electronic Engineering, YU-KIST, Yonsei University, Seoul, 03722, Republic of Korea
| | - Won-Gun Koh
- Department of Chemical and Biomolecular Engineering, College of Engineering, Yonsei University, Seoul, 03722, Republic of Korea
| | - Justin J Chung
- Transdisciplinary Department of Medicine and Advanced Technology, Seoul National University Hospital, Seoul, 03080, Republic of Korea.,Department of Medicine, Seoul National University College of Medicine, Seoul, 03080, Republic of Korea
| |
Collapse
|
2
|
Pang R, Miseki Y, Sayama K. Enhanced HClO production from chloride by dual cocatalyst loaded WO 3 under visible light. Catal Sci Technol 2022. [DOI: 10.1039/d1cy02194j] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
Photocatalytic production of HClO was improved more than twice by co-loading of Mn compared to the standard Pt/WO3.
Collapse
Affiliation(s)
- Rui Pang
- Artificial Photosynthesis Research Team, Global Zero Emission Research Center, National Institute of Advanced Industrial Science and Technology, Tsukuba West, 16-1, Onogawa, Tsukuba, Ibaraki, 305-0053, Japan
| | - Yugo Miseki
- Artificial Photosynthesis Research Team, Global Zero Emission Research Center, National Institute of Advanced Industrial Science and Technology, Tsukuba West, 16-1, Onogawa, Tsukuba, Ibaraki, 305-0053, Japan
| | - Kazuhiro Sayama
- Artificial Photosynthesis Research Team, Global Zero Emission Research Center, National Institute of Advanced Industrial Science and Technology, Tsukuba West, 16-1, Onogawa, Tsukuba, Ibaraki, 305-0053, Japan
| |
Collapse
|
3
|
Lu N, Sun S, Chu F, Wang M, Zhao Q, Shi J, Jia R. Identification and inactivation of Gordonia, a new chlorine-resistant bacterium isolated from a drinking water distribution system. JOURNAL OF WATER AND HEALTH 2020; 18:995-1008. [PMID: 33328370 DOI: 10.2166/wh.2020.143] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Chlorine-resistant bacteria threaten drinking water safety in water distribution systems. In this study, a novel chlorine-resistant bacterium identified as Gordonia was isolated from the drinking water supply system of Jinan City for the first time. We examined the resistance and inactivation of the isolate by investigating cell survival, changes in cell morphology, and the permeability of cell membranes exposed to chlorine. After 240 min chlorine exposure, the chlorine residual was greater than 0.5 mg L-1 and the final inactivation was about 3 log reduction, which showed that the Gordonia strain had high chlorine tolerance. Flow-cytometric analysis indicated that, following sodium hypochlorite treatments with increasing membrane permeability, culturable cells enter a viable but nonculturable state and then die. We also investigated the inactivation kinetics of Gordonia following chlorine dioxide and ultraviolet radiation treatment. We found that these treatments can effectively inactivate Gordonia, which suggests that they may be used for the regulation of chlorine-resistant microorganisms.
Collapse
Affiliation(s)
- Nannan Lu
- Shandong Province Water Supply and Drainage Monitoring Center, No.5111, Aotizhong Road, Jinan, China E-mail:
| | - Shaohua Sun
- Shandong Province Water Supply and Drainage Monitoring Center, No.5111, Aotizhong Road, Jinan, China E-mail:
| | - Fumin Chu
- Shandong Province Water Supply and Drainage Monitoring Center, No.5111, Aotizhong Road, Jinan, China E-mail:
| | - Mingquan Wang
- Shandong Province Water Supply and Drainage Monitoring Center, No.5111, Aotizhong Road, Jinan, China E-mail:
| | - Qinghua Zhao
- Shandong Province Water Supply and Drainage Monitoring Center, No.5111, Aotizhong Road, Jinan, China E-mail:
| | - Jinmiao Shi
- Shandong Province Water Supply and Drainage Monitoring Center, No.5111, Aotizhong Road, Jinan, China E-mail:
| | - Ruibao Jia
- Shandong Province Water Supply and Drainage Monitoring Center, No.5111, Aotizhong Road, Jinan, China E-mail:
| |
Collapse
|
4
|
Evaluation of Fecal Coliform Prevalence and Physicochemical Indicators in the Effluent from a Wastewater Treatment Plant in the North-West Province, South Africa. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:ijerph17176381. [PMID: 32887228 PMCID: PMC7503972 DOI: 10.3390/ijerph17176381] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/20/2020] [Revised: 08/15/2020] [Accepted: 08/23/2020] [Indexed: 11/17/2022]
Abstract
Compliance of the effluents from wastewater treatment plants (WWTPs) to the regulatory standards, which mostly entail the removal/reduction of organic waste and deactivation of the potential microbial pathogens is of great importance. The detection of indicator parameters can be used to determine the effectiveness of a WWTP and the level of compliance with the South African regulatory standards. The performance of the WWTP was assessed by biological, physical and chemical measures in wastewater final effluent. The Escherichia coli ranged from 0 and 2420 count/100 mL in the final effluent. The recorded values for the physicochemical parameters were within the following ranges: pH (7.03-8.49), electrical conductivity (81.63-126.5 mS/m), suspended solids (0.40-20.4 mg/L), ammonia (0-22.15 mg/L), Chemical Oxygen Demand (COD) (1-73 mg/L), nitrate (0-16.1 mg/L), ortho-phosphate (0-8.58 mg/L) and free chlorine (0-3.21 mg/L). Furthermore, the concentration of toxic heavy metals was recorded to be between 1-10 ug/L for arsenic, cadmium, lead and mercury. In conclusion, all the parameters that were evaluated in this study indicate that the studied WWTP is performing in accordance with the prescribed general limits.
Collapse
|
5
|
Assessing the Impact of Cyanuric Acid on Bather’s Risk of Gastrointestinal Illness at Swimming Pools. WATER 2019. [DOI: 10.3390/w11061314] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Current regulatory codes for swimming pool disinfection separately regulate free chlorine (FC) and cyanuric acid (CYA). It is well-known that CYA affects disinfection rates by reversibly binding to FC in aqueous solutions. However, limits for these regulated parameters have neither systematically accounted for this chemistry nor been based on the risk of gastrointestinal illness. This study was intended to determine the minimum concentration of FC relative to CYA based on the risk of gastrointestinal illness from normal fecal sloughing of selected pathogens and to find a simple regulatory rule for jointly managing FC and CYA for consistent disinfection. Literature data on CYA’s effect on microbial inactivation rates were reanalyzed based on the equilibria governing hypochlorous acid (HOCl) concentration. A model was developed that considers the rates of pathogen introduction into pool water, disinfection, turbulent diffusive transport, and pathogen uptake by swimmers to calculate the associated risk of illness. Model results were compared to U.S. Environmental Protection Agency (EPA) untreated recreational water acceptable gastrointestinal illness risk. For Cryptosporidium, correlation between log inactivation and Chick–Watson Ct was far better when C refers to HOCl concentration than to FC (r = −0.96 vs. −0.06). The HOCl concentration had a small variation (± 1.8%) at a constant CYA/FC ratio for typical FC and CYA ranges in swimming pools. In 27 U.S. states, the allowed FC and CYA results in HOCl concentrations spanning more than a factor of 500. Using conservative values for a high bather load pool with 2 mg/L FC and 90 mg/L CYA, the model predicted a 0.071 annual probability of infection for Giardia, exceeding the EPA regulatory 0.036 limit for untreated recreational waters. FC and CYA concentrations in swimming pools should be jointly regulated as a ratio. We recommend a maximum CYA/FC ratio of 20.
Collapse
|
6
|
Efficacy of Flushing and Chlorination in Removing Microorganisms from a Pilot Drinking Water Distribution System. WATER 2019. [DOI: 10.3390/w11050903] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
To ensure delivery of microbiologically safe drinking water, the physical integrity of the distribution system is an important control measure. During repair works or an incident the drinking water pipe is open and microbiologically contaminated water or soil may enter. Before taking the pipe back into service it must be cleaned. The efficacy of flushing and shock chlorination was tested using a model pipe-loop system with a natural or cultured biofilm to which a microbial contamination (Escherichia coli, Clostridium perfringens spores and phiX174) was added. On average, flushing removed 1.5–2.7 log microorganisms from the water, but not the biofilm. In addition, sand added to the system was not completely removed. Flushing velocity (0.3 or 1.5 m/s) did not affect the efficacy. Shock chlorination (10 mg/L, 1–24 h) was very effective against E. coli and phiX174, but C. perfringens spores were partly resistant. Chlorination was slightly more effective in pipes with a natural compared to a cultured biofilm. Flushing alone is thus not sufficient after high risk repair works or incidents, and shock chlorination should be considered to remove microorganisms to ensure microbiologically safe drinking water. Prevention via hygienic working procedures, localizing and isolating the contamination source and issuing boil water advisories remain important, especially during confirmed contamination events.
Collapse
|
7
|
Keithley SE, Fakhreddine S, Kinney KA, Kirisits MJ. Effect of Treatment on the Quality of Harvested Rainwater for Residential Systems. ACTA ACUST UNITED AC 2018. [DOI: 10.1002/awwa.1054] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Sarah E. Keithley
- Tighe & Bond; Westwood Mass
- Department of Civil, Architectural and Environmental Engineering; University of Texas; Austin Tex
| | - Sarah Fakhreddine
- Department of Civil, Architectural and Environmental Engineering; University of Texas; Austin Tex
- Department of Earth System Sciences; Stanford University; Stanford Calif
| | - Kerry A. Kinney
- Department of Civil, Architectural and Environmental Engineering; University of Texas; Austin Tex
| | - Mary Jo Kirisits
- Department of Civil, Architectural and Environmental Engineering; University of Texas; Austin Tex
| |
Collapse
|
8
|
Murray AL, Kumpel E, Peletz R, Khush RS, Lantagne DS. The effect of sodium thiosulfate dechlorination on fecal indicator bacteria enumeration: laboratory and field data. JOURNAL OF WATER AND HEALTH 2018; 16:70-77. [PMID: 29424720 DOI: 10.2166/wh.2017.077] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
In microbiological water quality testing, sample dechlorination with sodium thiosulfate is recommended to ensure that results accurately reflect the water quality at sample collection. Nevertheless, monitoring institutions in low-resource settings do not always dechlorinate samples, and there is limited research describing how this practice impacts drinking water quality results. The effect of dechlorination on indicator bacteria counts was evaluated by spiking laboratory water with five Escherichia coli (E. coli) concentrations (104-108 CFU/100 mL), chlorinating at six doses (0-0.6 mg/L), holding samples with and without sodium thiosulfate for 5-7 hours, and enumerating E. coli by membrane filtration with m-lauryl sulfate media. Additionally, sub-Saharan African water suppliers enumerated thermotolerant coliform by membrane filtration in paired chlorinated water samples collected with and without sodium thiosulfate. Across all E. coli and chlorine doses in the laboratory, and all field tests, samples held without sodium thiosulfate had lower bacteria counts (p < 0.001). Additionally, chlorinated water supply samples held without sodium thiosulfate had an 87.5% false negative rate. Results indicate the importance of dechlorinating microbiological water quality samples, discarding data from chlorinated samples collected without dechlorination, and reinforcing dechlorination recommendations in resource-limited environments to improve water safety management.
Collapse
Affiliation(s)
- Anna L Murray
- Department of Civil and Environmental Engineering, Tufts University, 200 College Avenue, Medford, MA 02155, USA E-mail:
| | - Emily Kumpel
- The Aquaya Institute, Riara Corporate Suites, Suite #203, Riara Road, Kilimani Estate, Nairobi, Kenya
| | - Rachel Peletz
- The Aquaya Institute, Riara Corporate Suites, Suite #203, Riara Road, Kilimani Estate, Nairobi, Kenya
| | - Ranjiv S Khush
- The Aquaya Institute, 12 E Sir Francis Drake Blvd Suite E, Larkspur, CA 94939, USA
| | - Daniele S Lantagne
- Department of Civil and Environmental Engineering, Tufts University, 200 College Avenue, Medford, MA 02155, USA E-mail:
| |
Collapse
|
9
|
Shazer A, Stewart D, Deng K, Tortorello M. Approaches toward Identification of Surrogates To Validate Antimicrobial Washes as Preventive Controls for Fresh-Cut Leafy Greens. J Food Prot 2017; 80:1600-1604. [PMID: 28853631 DOI: 10.4315/0362-028x.jfp-17-069] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
In fresh-cut produce production, antimicrobials may be used during washing to control the risk of cross-contamination by microbial hazards. Surrogate microorganisms have long been used to validate processes, but none have been identified for validating the efficacy of antimicrobial washing of fresh-cut produce. The objective of this study was to develop procedures by which surrogates may be identified for use in validating the control of cross-contamination for fresh-cut lettuce operations. Four microbial characteristics, which may be important factors in cross-contamination events, were quantitatively evaluated in potential surrogate microorganisms for comparison to a reasonably foreseeable hazard, Escherichia coli O157:H7: sensitivity to chlorine in solution, sensitivity to chlorine on lettuce leaf surfaces, shedding from contaminated lettuce leaves into the water during washing, and cross-contamination from inoculated to uninoculated lettuce leaves during chorine washing. A procedure of practical quantitative experiments for comparing the characteristics reduced the original pool of 80 potential strains, which consisted of lactic acid bacteria, probiotics, and isolates obtained from lettuce enrichment cultures, to five strains: Lactobacillus plantarum, Pediococcus pentosaceus, probiotic 22C, and two lettuce enrichment isolates. These strains may be evaluated in additional studies involving comparisons to other reasonably foreseeable hazards and including other potential process variables that should be understood and controlled to prevent cross-contamination in fresh-cut lettuce operations.
Collapse
Affiliation(s)
- A Shazer
- 1 U.S. Food and Drug Administration, Division of Food Processing Science and Technology, Illinois Institute of Technology, 6502 South Archer Road, Bedford Park, Illinois 60501, USA
| | - D Stewart
- 1 U.S. Food and Drug Administration, Division of Food Processing Science and Technology, Illinois Institute of Technology, 6502 South Archer Road, Bedford Park, Illinois 60501, USA
| | - K Deng
- 2 Institute for Food Safety and Health, Illinois Institute of Technology, 6502 South Archer Road, Bedford Park, Illinois 60501, USA
| | - M Tortorello
- 1 U.S. Food and Drug Administration, Division of Food Processing Science and Technology, Illinois Institute of Technology, 6502 South Archer Road, Bedford Park, Illinois 60501, USA
| |
Collapse
|
10
|
Chlorine Tolerance and Inactivation of Escherichia coli recovered from Wastewater Treatment Plants in the Eastern Cape, South Africa. APPLIED SCIENCES-BASEL 2017. [DOI: 10.3390/app7080810] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
11
|
Effects of phenyllactic acid as sanitizing agent for inactivation of Listeria monocytogenes biofilms. Food Control 2017. [DOI: 10.1016/j.foodcont.2017.02.050] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
12
|
Swanson S, Fu TJ. Effect of Water Hardness on Efficacy of Sodium Hypochlorite Inactivation of Escherichia coli O157:H7 in Water. J Food Prot 2017; 80:497-501. [PMID: 28207312 DOI: 10.4315/0362-028x.jfp-16-112] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
This study examined how the hardness of water affected the efficacy of sodium hypochlorite in inactivating Escherichia coli O157:H7 in water. Water was prepared at different degrees of total hardness (0, 50, 100, 200, 500, 1,000, 2,000, and 5,000 mg/liter CaCO3). Inactivation was assessed at different levels of free chlorine (0, 0.2, 0.5, and 1.0 ppm) at 2 to 4°C and pH 6.5. Thirty milliliters of chlorinated water was inoculated with 6 log CFU/ml of E. coli O157:H7 and allowed to mix for 3, 10, 20, or 30 s. In the absence of sodium hypochlorite, no reduction in counts of E. coli O157:H7 was observed regardless of the degree of water hardness. However, in the presence of hard water, under certain chlorine concentrations and exposure times, the reduction of E. coli O157:H7 in chlorinated hard water was significantly less than the reduction observed in chlorinated deionized water. For example, after exposure to 0.5 ppm of free chlorine for 10 s, E. coli O157:H7 counts were reduced by 4.8 ± 1.4, 2.0 ± 1.3, 1.6 ± 0.7, 0.5 ± 0.7, and 0.0 ± 0.1 log CFU/ml in water containing 0, 100, 1,000, 2,000, and 5,000 mg/liter CaCO3, respectively. With the exception of 5,000 mg/liter CaCO3, the effect of water hardness was no longer visible after 20 s of exposure to 0.5 ppm of free chlorine. Also, hard water significantly lowered the efficacy of sodium hypochlorite at 3 s of exposure to 1.0 ppm of free chlorine. But after 20 s of exposure to 1.0 ppm of free chlorine, the impact of water hardness was no longer observed. This study demonstrated that water hardness can affect the germicidal efficacy of sodium hypochlorite, and such an impact may or may not be apparent depending on the condition of the solution and the treatment time at which the observation is made. Under the conditions typically seen in commercial produce washing operations, the impact of water hardness on chlorine efficacy is likely to be insignificant compared with that of organic load.
Collapse
Affiliation(s)
- Sara Swanson
- Institute for Food Safety and Health, Illinois Institute of Technology, 6502 South Archer Road, Bedford Park, Illinois 60501
| | - Tong-Jen Fu
- U.S. Food and Drug Administration, Division of Food Processing Science and Technology, 6502 South Archer Road, Bedford Park, Illinois 60501, USA
| |
Collapse
|
13
|
Maharjan P, Clark T, Kuenzel C, Foy M, Watkins S. On farm monitoring of the impact of water system sanitation on microbial levels in broiler house water supplies. J APPL POULTRY RES 2016. [DOI: 10.3382/japr/pfw010] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
14
|
Gil MI, Marín A, Andujar S, Allende A. Should chlorate residues be of concern in fresh-cut salads? Food Control 2016. [DOI: 10.1016/j.foodcont.2015.08.023] [Citation(s) in RCA: 63] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
15
|
Hessain AM, Al-Arfaj AA, Zakri AM, El-Jakee JK, Al-Zogibi OG, Hemeg HA, Ibrahim IM. Molecular characterization of Escherichia coli O157:H7 recovered from meat and meat products relevant to human health in Riyadh, Saudi Arabia. Saudi J Biol Sci 2015; 22:725-9. [PMID: 26587000 PMCID: PMC4625360 DOI: 10.1016/j.sjbs.2015.06.009] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2015] [Revised: 05/31/2015] [Accepted: 06/10/2015] [Indexed: 11/17/2022] Open
Abstract
Raw meat can harbor pathogenic bacteria, potentially harmful to humans such as Escherichia coli O157:H7 causing diarrhea and hemolytic-uremic syndrome (HS). Therefore, the current study was carried out to evaluate the prevalence and the molecular detection characterization of E. coli serotype O157:H7 recovered from raw meat and meat products collected from Saudi Arabia. During the period of 25th January 2013 to 25th March 2014, 370 meat samples were collected from abattoirs and markets located in Riyadh, Saudi Arabia "200 raw meat samples and 170 meat products". Bacteriological analysis of the meat samples and serotyping of the isolated E. coli revealed the isolation of 11 (2.97%) strains of E. coli O157:H7. Isolation of E. coli O157:H7 in raw beef, chicken and mutton were 2%, 2.5%, and 2.5%, respectively, however, there was no occurrence in raw turkey. The incidences of E. coli O157:H7 in ground beef, beef burgers, beef sausage, ground chicken and chicken burgers were 5%, 10%, 0.0%, 5% and 0.0%, respectively. The multiplex PCR assay revealed that 3 (27.27%) out of 11 E. coli O157:H7 isolates from raw beef, chicken and mutton had stx1, stx2, and eae while 5 (45.45%) E. coli O157:H7 isolates from ground beef, ground chicken, and raw beef had both stx1 and stx2. However, from beef burgers, only one E. coli O157:H7 isolate had stx1 while two were positive for hlyA gene. These results call for urgent attention toward appropriate controls and good hygienic practices in dealing with raw meat.
Collapse
Affiliation(s)
- Ashgan M. Hessain
- Department of Health Science, College of Applied Studies and Community Service, King Saud University, P.O. Box 22459, Riyadh 11495, Saudi Arabia
- Department of Microbiology, Faculty of Veterinary Medicine, Cairo University, P.O. Box 2446, Cairo 14242, Giza, Egypt
| | - Abdullah A. Al-Arfaj
- Department of Botany and Microbiology, College of Science, King Saud University, P.O. Box 2455, Riyadh 11451, Saudi Arabia
| | - Adel M. Zakri
- Department of Plant Production, College of Food and Agriculture Science, King Saud University, P.O. Box 2466, Riyadh 11451, Saudi Arabia
| | - Jakeen K. El-Jakee
- Department of Microbiology, Faculty of Veterinary Medicine, Cairo University, P.O. Box 2446, Cairo 14242, Giza, Egypt
| | - Onizan G. Al-Zogibi
- Department of Biology, Faculty of Science, King Abdulaziz University, P.O. Box 80203, Jeddah, Saudi Arabia
| | - Hassan A. Hemeg
- Department of Medical Technology/Microbiology, College of Applied Medical Science, Taibah University, Madinah, Saudi Arabia
| | - Ihab M. Ibrahim
- Department of Botany and Microbiology, College of Science, King Saud University, P.O. Box 2455, Riyadh 11451, Saudi Arabia
| |
Collapse
|
16
|
Ovissipour M, Al-Qadiri HM, Sablani SS, Govindan BN, Al-Alami N, Rasco B. Efficacy of acidic and alkaline electrolyzed water for inactivating Escherichia coli O104:H4, Listeria monocytogenes, Campylobacter jejuni, Aeromonas hydrophila, and Vibrio parahaemolyticus in cell suspensions. Food Control 2015. [DOI: 10.1016/j.foodcont.2015.01.006] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
17
|
Van Haute S, Tryland I, Veys A, Sampers I. Wash water disinfection of a full-scale leafy vegetables washing process with hydrogen peroxide and the use of a commercial metal ion mixture to improve disinfection efficiency. Food Control 2015. [DOI: 10.1016/j.foodcont.2014.08.028] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
18
|
Lantagne D. Comment on "household effectiveness vs. laboratory efficacy of point-of-use chlorination". WATER RESEARCH 2015; 69:328-330. [PMID: 25500331 DOI: 10.1016/j.watres.2014.10.053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/31/2014] [Revised: 10/21/2014] [Accepted: 10/24/2014] [Indexed: 06/04/2023]
Affiliation(s)
- Daniele Lantagne
- Department of Civil and Environmental Engineering, Tufts University, USA.
| |
Collapse
|
19
|
Zhao T, Zhao P, Chen D, Jadeja R, Hung YC, Doyle MP. Reductions of Shiga toxin-producing Escherichia coli and Salmonella typhimurium on beef trim by lactic acid, levulinic acid, and sodium dodecyl sulfate treatments. J Food Prot 2014; 77:528-37. [PMID: 24680063 DOI: 10.4315/0362-028x.jfp-13-335] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Studies were done at 21 °C to determine the bactericidal activity of lactic acid, levulinic acid, and sodium dodecyl sulfate (SDS) applied individually and in combination on Shiga toxin-producing Escherichia coli (STEC) in pure culture and to compare the efficacy of lactic acid and levulinic acid plus SDS treatments applied by spray or immersion to inactivate STEC and Salmonella (10(7) CFU/cm2) on beef trim pieces (10 by 10 by 7.5 cm). Application of 3% lactic acid for 2 min to pure cultures was shown to reduce E. coli O26:H11, O45:H2, O111:H8, O103:H2, O121:H2, O145:NM, and O157:H7 populations by 2.1, 0.4, 0.3, 1.4, 0.3, 2.1, and 1.7 log CFU/ml, respectively. Treatment with 0.5% levulinic acid plus 0.05% SDS for <1 min reduced the populations of all STEC strains to undetectable levels (>6 log/ml reduction). Beef surface temperature was found to affect the bactericidal activity of treatment with 3 % levulinic acid plus 2% SDS (LV-SDS). Treating cold (4 °C) beef trim with LV-SDS at 21, 62, or 81 °C for 30 s reduced E. coli O157:H7 by 1.0, 1.1, or 1.4 log CFU/cm2, respectively, whereas treating beef trim at 8 °C with LV-SDS at 12 °C for 0.1, 1, 3, or 5 min reduced E. coli O157:H7 by 1.4, 2.4, 2.5, or 3.3 log CFU/cm(2), respectively. Spray treatment of beef trim at 4 °C with 5 % lactic acid only reduced the E. coli O157:H7 population by 1.3 log CFU/cm2. Treating beef trim at 8 °C with LV-SDS for 1, 2, or 3 min reduced Salmonella Typhimurium by 2.1, 2.6, and >5.0 log CFU/cm2, respectively. Hand massaging the treated beef trim substantially reduced contamination of both pathogens, with no detectable E. coli O157:H7 or Salmonella Typhimurium (<5 CFU/cm2) on beef trim pieces treated with LV-SDS. Reduction of E. coli O157:H7 and Salmonella Typhimurium populations was enhanced, but bactericidal activity was affected by the meat temperature.
Collapse
Affiliation(s)
- Tong Zhao
- Center for Food Safety, College of Agricultural and Environmental Sciences, The University of Georgia, 1109 Experiment Street, Griffin, Georgia 30223, USA
| | - Ping Zhao
- Center for Food Safety, College of Agricultural and Environmental Sciences, The University of Georgia, 1109 Experiment Street, Griffin, Georgia 30223, USA
| | - Dong Chen
- Center for Food Safety, College of Agricultural and Environmental Sciences, The University of Georgia, 1109 Experiment Street, Griffin, Georgia 30223, USA
| | - Ravirajsinh Jadeja
- Department of Food Science and Technology, College of Agricultural and Environmental Sciences, The University of Georgia, 1109 Experiment Street, Griffin, Georgia 30223, USA
| | - Yen-Con Hung
- Department of Food Science and Technology, College of Agricultural and Environmental Sciences, The University of Georgia, 1109 Experiment Street, Griffin, Georgia 30223, USA
| | - Michael P Doyle
- Center for Food Safety, College of Agricultural and Environmental Sciences, The University of Georgia, 1109 Experiment Street, Griffin, Georgia 30223, USA.
| |
Collapse
|
20
|
Effect of chlorine exposure on the survival and antibiotic gene expression of multidrug resistant Acinetobacter baumannii in water. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2014; 11:1844-54. [PMID: 24514427 PMCID: PMC3945572 DOI: 10.3390/ijerph110201844] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/12/2013] [Revised: 01/23/2014] [Accepted: 01/28/2014] [Indexed: 02/05/2023]
Abstract
Acinetobacter baumannii is a multidrug resistant pathogen capable of causing a wide spectrum of clinical conditions in humans. Acinetobacter spp. is ubiquitously found in different water sources. Chlorine being the most commonly used disinfectant in water, the study investigated the effect of chlorine on the survival of A. baumannii in water and transcription of genes conferring antibiotic resistance. Eight clinical isolates of A. baumannii, including a fatal meningitis isolate (ATCC 17978) (~108 CFU/mL) were separately exposed to free chlorine concentrations (0.2, 1, 2, 3 and 4 ppm) with a contact time of 30, 60, 90 and 120 second. The surviving pathogen counts at each specified contact time were determined using broth dilution assay. In addition, real-time quantitative PCR (RT-qPCR) analysis of the antibiotic resistance genes (efflux pump genes and those encoding resistance to specific antibiotics) of three selected A. baumannii strains following exposure to chlorine was performed. Results revealed that all eight A. baumannii isolates survived the tested chlorine levels during all exposure times (p > 0.05). Additionally, there was an up-regulation of all or some of the antibiotic resistance genes in A. baumannii, indicating a chlorine-associated induction of antibiotic resistance in the pathogen.
Collapse
|
21
|
Van Haute S, Sampers I, Holvoet K, Uyttendaele M. Physicochemical quality and chemical safety of chlorine as a reconditioning agent and wash water disinfectant for fresh-cut lettuce washing. Appl Environ Microbiol 2013; 79:2850-61. [PMID: 23396332 PMCID: PMC3623159 DOI: 10.1128/aem.03283-12] [Citation(s) in RCA: 148] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2012] [Accepted: 02/01/2013] [Indexed: 11/20/2022] Open
Abstract
Chlorine was assessed as a reconditioning agent and wash water disinfectant in the fresh-cut produce industry. Artificial fresh-cut lettuce wash water, made from butterhead lettuce, was used for the experiments. In the reconditioning experiments, chlorine was added to artificial wash water inoculated with Escherichia coli O157 (6 log CFU/ml). Regression models were constructed based on the inactivation data and validated in actual wash water from leafy vegetable processing companies. The model that incorporated chlorine dose and chemical oxygen demand (COD) of the wash water accurately predicted inactivation. Listeria monocytogenes was more resistant to chlorine reconditioning in artificial wash water than Salmonella spp. and Escherichia coli O157. During the washing process with inoculated lettuce (4 log CFU/g), in the absence of chlorine, there was a rapid microbial buildup in the water that accumulated to 5.4 ± 0.4 log CFU/100 ml after 1 h. When maintaining a residual concentration of 1 mg/liter free chlorine, wash water contamination was maintained below 2.7, 2.5, and 2.5 log CFU/100 ml for tap water and artificial process water with COD values of 500 and 1,000 mg O2/liter, respectively. A model was developed to predict water contamination during the dynamic washing process. Only minor amounts of total trihalomethanes were formed in the water during reconditioning. Total trihalomethanes accumulated to larger amounts in the water during the wash water disinfection experiments and reached 124.5 ± 13.4 μg/liter after 1 h of execution of the washing process in water with a COD of 1,000 mg O2/liter. However, no total trihalomethanes were found on the fresh-cut lettuce after rinsing.
Collapse
Affiliation(s)
- Sam Van Haute
- Laboratory of Food Microbiology and Food Preservation, Department of Food Safety and Food Quality, Faculty of Bioscience Engineering, Ghent University, Ghent, Belgium
- Research Group EnBiChem, Department of Industrial Engineering and Technology, University College West Flanders, Association Ghent University (Howest-AUGent), Kortrijk, Belgium
| | - Imca Sampers
- Research Group EnBiChem, Department of Industrial Engineering and Technology, University College West Flanders, Association Ghent University (Howest-AUGent), Kortrijk, Belgium
| | - Kevin Holvoet
- Laboratory of Food Microbiology and Food Preservation, Department of Food Safety and Food Quality, Faculty of Bioscience Engineering, Ghent University, Ghent, Belgium
- Research Group EnBiChem, Department of Industrial Engineering and Technology, University College West Flanders, Association Ghent University (Howest-AUGent), Kortrijk, Belgium
| | - Mieke Uyttendaele
- Laboratory of Food Microbiology and Food Preservation, Department of Food Safety and Food Quality, Faculty of Bioscience Engineering, Ghent University, Ghent, Belgium
| |
Collapse
|
22
|
Shen C, Luo Y, Nou X, Wang Q, Millner P. Dynamic effects of free chlorine concentration, organic load, and exposure time on the inactivation of Salmonella, Escherichia coli O157:H7, and non-O157 Shiga toxin-producing E. coli. J Food Prot 2013; 76:386-93. [PMID: 23462074 DOI: 10.4315/0362-028x.jfp-12-320] [Citation(s) in RCA: 79] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
This study evaluated the dynamic effects of free-chlorine (FC) concentration, contact time, and organic load on the inactivation of Salmonella, Escherichia coli O157:H7, and non-O157 Shiga toxin-producing E. coli (STEC) in suspension. Bacterial cells from four strains each of Salmonella, E. coli O157:H7, and non-O157 STEC were inoculated separately or as a multistrain cocktail into solutions with varying FC concentrations. Lettuce or tomato extract was used to simulate the organic matter present during commercial fresh and fresh-cut produce wash operations. After exposure to FC for various lengths of time, the bacterial survival and water-quality changes were determined. In the absence of organic matter in a wash solution, pathogen inactivation is primarily a function of initial FC concentration (P < 0.0001), exposure time (P < 0.0001), and pathogen strains (P < 0.0001). In general, an over 4.5-log CFU/ml pathogen reduction was found after exposure to >0.5 mg/liter FC for over 30 s, or to >1.0 mg/liter FC for over 5 s. When the combination of FC concentration and contact time were less than or equal to the above conditions, survival of pathogens was strain dependant and ranked as: Salmonella > E. coli O157:H7 > non-O157 STEC. When organic matter was present in the wash solution, pathogen inactivation efficacy was specifically dependent on the residual FC concentration, which directly relates to both the initial FC concentration and the organic load. Prevention of pathogen survival in chlorinated produce wash solutions can be achieved by maintaining sufficient FC concentration and reducing the accumulation of organic matter.
Collapse
Affiliation(s)
- Cangliang Shen
- U.S. Department of Agriculture, Agricultural Research Service, Environmental Microbial and Food Safety Laboratory, 10300 Baltimore Avenue, Beltsville, Maryland 20705, USA
| | | | | | | | | |
Collapse
|
23
|
Munther D, Wu J. Enhanced surveillance on food-borne disease outbreaks: dynamics of cross-contamination in biocidal wash procedure. J Theor Biol 2013; 321:28-35. [PMID: 23298732 DOI: 10.1016/j.jtbi.2012.12.024] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2012] [Revised: 12/18/2012] [Accepted: 12/29/2012] [Indexed: 11/30/2022]
Abstract
Understanding the geographic and temporal spread of food-borne diseases associated with fresh produce is crucial for informing adequate surveillance and control. As a first step towards this goal, we develop and analyze a novel three stage model at the processing/sanitization juncture in the fresh produce supply chain. The key feature of our model is its ability to describe the dynamics of cross-contamination during commercial wash procedures. In general, we quantify the degree of cross-contamination in terms of model parameters. Applying these results in the case of Escherichia coli O157:H7 contamination of fresh-cut romaine lettuce, we identify the mean wash time and free chlorine concentration as critical parameters. In addition to showing how these parameters affect contamination levels, we recommend that in order to prevent potential source misidentification, at least 2.2 mg/L of free chlorine should be used during a wash lasting at least 30s.
Collapse
Affiliation(s)
- Daniel Munther
- Centre for Disease Modelling, Department of Mathematics and Statistics, York University, Toronto, Canada.
| | | |
Collapse
|
24
|
Kalin R, Ongor H, Cetinkaya B. Isolation and molecular characterization of Escherichia coli O157 from broiler and human samples. Foodborne Pathog Dis 2012; 9:313-8. [PMID: 22304630 DOI: 10.1089/fpd.2011.0991] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
There is a lack of information about the role of poultry, specifically chicken, in transmission of Escherichia coli (E. coli) O157 and subsequent human illnesses. This study was therefore aimed at investigating the presence of E. coli O157 and its virulence genes in various samples collected from broiler chickens and humans in Eastern Turkey by culture, immunomagnetic separation (IMS), and polymerase chain reaction (PCR). The genetic relationship between broiler and human isolates was also examined by pulsed-field gel electrophoresis (PFGE). In the PCR analysis of sorbitol-negative isolates, E. coli O157 was identified in 0.1% (1/1000) and 0.4% (4/1000) of the liver and cecum samples of broiler chickens, respectively. On the other hand, none of the carcass samples were determined to be positive for E. coli O157. Overall, the results indicated that 12% (3/25) of the flocks were positive for E. coli O157. The differences between the flocks in terms of the positivity were determined to be statistically significant (p<0.001). Ten (2.7%) of 367 human stool samples were also positive for E. coli O157 in the PCR examination. None of the broiler and human E. coli O157 isolates possessed H7, shigatoxins 1-2, or enterohemolysin genes, whereas all the broiler isolates and one of the human isolates were positive for intimin gene. In the PFGE analysis, a total of eight different profiles (four from broiler and four from human isolates) were observed. However, there were no genetic relationships between broiler and human E. coli O157 isolates. It can be concluded that more detailed studies are needed in poultry to better understand the role of these species in the epidemiology of E. coli 0157 infections in humans.
Collapse
Affiliation(s)
- Recep Kalin
- Department of Microbiology, Faculty of Veterinary Medicine, University of Firat, Elazig, Turkey.
| | | | | |
Collapse
|
25
|
Luo Y, Nou X, Yang Y, Alegre I, Turner E, Feng H, Abadias M, Conway W. Determination of free chlorine concentrations needed to prevent Escherichia coli O157:H7 cross-contamination during fresh-cut produce wash. J Food Prot 2011; 74:352-8. [PMID: 21375869 DOI: 10.4315/0362-028x.jfp-10-429] [Citation(s) in RCA: 135] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
This study was conducted to investigate the effect of free chlorine concentrations in wash water on Escherichia coli O157:H7 reduction, survival, and transference during washing of fresh-cut lettuce. The effectiveness of rewashing for inactivation of E. coli O157:H7 on newly cross-contaminated produce previously washed with solutions containing an insufficient amount of chlorine also was assessed. Results indicate that solutions containing a minimum of 0.5 mg/liter free chlorine were effective for inactivating E. coli O157:H7 in suspension to below the detection level. However, the presence of 1 mg/liter free chlorine in the wash solution before washing was insufficient to prevent E. coli O157:H7 survival and transfer during washing because the introduction of cut lettuce to the wash system quickly depleted the free chlorine. Although no E. coli O157:H7 was detected in the wash solution containing 5 mg/liter free chlorine before washing a mix of inoculated and uninoculated lettuce, low numbers of E. coli O157:H7 cells were detected on uninoculated lettuce in four of the seven experimental trials. When the prewash free chlorine concentration was increased to 10 mg/liter or greater, no E. coli O157:H7 transfer was detected. Furthermore, although rewashing newly cross-contaminated lettuce in 50 mg/liter free chlorine for 30 s significantly reduced (P = 0.002) the E. coli O157:H7 populations, it failed to eliminate E. coli O157:H7 on lettuce. This finding suggests that rewashing is not an effective way to correct for process failure, and maintaining a sufficient free chlorine concentration in the wash solution is critical for preventing pathogen cross-contamination.
Collapse
Affiliation(s)
- Yaguang Luo
- U.S. Department of Agriculture, Agricultural Research Service, Environmental Microbial and Food Safety Laboratory, Beltsville, MD 20705, USA.
| | | | | | | | | | | | | | | |
Collapse
|
26
|
Erkmen O. Antimicrobial Effects of Hypochlorite onEscherichia coliin Water and Selected Vegetables. Foodborne Pathog Dis 2010; 7:953-8. [DOI: 10.1089/fpd.2009.0509] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Affiliation(s)
- Osman Erkmen
- Department of Food Engineering, Faculty of Engineering, University of Gaziantep, Gaziantep, Turkey
| |
Collapse
|
27
|
Variability of Burkholderia pseudomallei strain sensitivities to chlorine disinfection. Appl Environ Microbiol 2009; 75:5405-9. [PMID: 19542324 DOI: 10.1128/aem.00062-09] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Burkholderia pseudomallei is a select agent and the causative agent of melioidosis. Variations in previously reported chlorine and monochloramine concentration time (Ct) values for disinfection of this organism make decisions regarding the appropriate levels of chlorine in water treatment systems difficult. This study identified the variation in Ct values for 2-, 3-, and 4-log(10) reductions of eight environmental and clinical isolates of B. pseudomallei in phosphate-buffered water. The greatest calculated Ct values for a 4-log(10) inactivation were 7.8 mg.min/liter for free available chlorine (FAC) at pH 8 and 5 degrees C and 550 mg.min/liter for monochloramine at pH 8 and 5 degrees C. Ionic strength of test solutions, culture hold times in water, and cell washing were ruled out as sources of the differences in prior observations. Tolerance to FAC was correlated with the relative amount of extracellular material produced by each isolate. Solid-phase cytometry analysis using an esterase-cleaved fluorochrome assay detected a 2-log(10)-higher level of organisms based upon metabolic activity than did culture, which in some cases increased Ct values by fivefold. Despite strain-to-strain variations in Ct values of 17-fold for FAC and 2.5-fold for monochloramine, standard FAC disinfection practices utilized in the United States should disinfect planktonic populations of these B. pseudomallei strains by 4 orders of magnitude in less than 10 min at the tested temperatures and pH levels.
Collapse
|
28
|
Zhao T, Zhao P, West JW, Bernard JK, Cross HG, Doyle MP. Inactivation of enterohemorrhagic Escherichia coli in rumen content- or feces-contaminated drinking water for cattle. Appl Environ Microbiol 2006; 72:3268-73. [PMID: 16672466 PMCID: PMC1472328 DOI: 10.1128/aem.72.5.3268-3273.2006] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2005] [Accepted: 02/26/2006] [Indexed: 11/20/2022] Open
Abstract
Cattle drinking water is a source of on-farm Escherichia coli O157:H7 transmission. The antimicrobial activities of disinfectants to control E. coli O157:H7 in on-farm drinking water are frequently neutralized by the presence of rumen content and manure that generally contaminate the drinking water. Different chemical treatments, including lactic acid, acidic calcium sulfate, chlorine, chlorine dioxide, hydrogen peroxide, caprylic acid, ozone, butyric acid, sodium benzoate, and competing E. coli, were tested individually or in combination for inactivation of E. coli O157:H7 in the presence of rumen content. Chlorine (5 ppm), ozone (22 to 24 ppm at 5 degrees C), and competing E. coli treatment of water had minimal effects (<1 log CFU/ml reduction) on killing E. coli O157:H7 in the presence of rumen content at water-to-rumen content ratios of 50:1 (vol/wt) and lower. Four chemical-treatment combinations, including (i) 0.1% lactic acid, 0.9% acidic calcium sulfate, and 0.05% caprylic acid (treatment A); (ii) 0.1% lactic acid, 0.9% acidic calcium sulfate, and 0.1% sodium benzoate (treatment B); (iii) 0.1% lactic acid, 0.9% acidic calcium sulfate, and 0.5% butyric acid (treatment C); and (iv) 0.1% lactic acid, 0.9% acidic calcium sulfate, and 100 ppm chlorine dioxide (treatment D); were highly effective (>3 log CFU/ml reduction) at 21 degrees C in killing E. coli O157:H7, O26:H11, and O111:NM in water heavily contaminated with rumen content (10:1 water/rumen content ratio [vol/wt]) or feces (20:1 water/feces ratio [vol/wt]). Among them, treatments A, B, and C killed >5 log CFU E. coli O157:H7, O26:H11, and O111:NM/ml within 30 min in water containing rumen content or feces, whereas treatment D inactivated approximately 3 to 4 log CFU/ml under the same conditions. Cattle given water containing treatment A or C or untreated water (control) ad libitum for two 7-day periods drank 15.2, 13.8, and 30.3 liters/day, respectively, and cattle given water containing 0.1% lactic acid plus 0.9% acidic calcium sulfate (pH 2.1) drank 18.6 liters/day. The amounts of water consumed for all water treatments were significantly different from that for the control, but there were no significant differences among the water treatments. Such treatments may best be applied periodically to drinking water troughs and then flushed, rather than being added continuously, to avoid reduced water consumption by cattle.
Collapse
Affiliation(s)
- Tong Zhao
- Center for Food Safety, University of Georgia, Griffin, GA 30223, USA
| | | | | | | | | | | |
Collapse
|
29
|
AL-HAQ MI, SUGIYAMA J, ISOBE S. Applications of Electrolyzed Water in Agriculture & Food Industries. FOOD SCIENCE AND TECHNOLOGY RESEARCH 2005. [DOI: 10.3136/fstr.11.135] [Citation(s) in RCA: 140] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
30
|
Stevenson SML, Cook SR, Bach SJ, McAllister TA. Effects of water source, dilution, storage, and bacterial and fecal loads on the efficacy of electrolyzed oxidizing water for the control of Escherichia coli O157:H7. J Food Prot 2004; 67:1377-83. [PMID: 15270489 DOI: 10.4315/0362-028x-67.7.1377] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
To evaluate the potential of using electrolyzed oxidizing (EO) water for controlling Escherichia coli O157:H7 in water for livestock, the effects of water source, electrolyte concentration, dilution, storage conditions, and bacterial or fecal load on the oxidative reduction potential (ORP) and bactericidal activity of EO water were investigated. Anode and combined (7:3 anode:cathode, vol/vol) EO waters reduced the pH and increased the ORP of deionized water, whereas cathode EO water increased pH and lowered ORP. Minimum concentrations (vol/vol) of anode and combined EO waters required to kill 10(4) CFU/ml planktonic suspensions of E. coli O157:H7 strain H4420 were 0.5 and 2.0%, respectively. Cathode EO water did not inhibit H4420 at concentrations up to 16% (vol/vol). Higher concentrations of anode or combined EO water were required to elevate the ORP of irrigation or chlorinated tap water compared with that of deionized water. Addition of feces to EO water products (0.5% anode or 2.0% combined, vol/vol) significantly reduced (P < 0.001) their ORP values to < 700 mV in all water types. A relationship between ORP and bactericidal activity of EO water was observed. The dilute EO waters retained the capacity to eliminate a 10(4) CFU/ml inoculation of E. coli O157:H7 H4420 for at least 70 h regardless of exposure to UV light or storage temperature (4 versus 24 degrees C). At 95 h and beyond, UV exposure reduced ORP, significantly more so (P < 0.05) in open than in closed containers. Bactericidal activity of EO products (anode or combined) was lost in samples in which ORP value had fallen to < or = 848 mV. When stored in the dark, the diluted EO waters retained an ORP of > 848 mV and bactericidal efficacy for at least 125 h; with refrigeration (4 degrees C), these conditions were retained for at least 180 h. Results suggest that EO water may be an effective means by which to control E. coli O157:H7 in livestock water with low organic matter content.
Collapse
Affiliation(s)
- S M L Stevenson
- Agriculture and Agri-Food Canada Research Centre, Lethbridge, Alberta, Canada T1J 4B1
| | | | | | | |
Collapse
|
31
|
Abstract
The inactivation kinetics of Listeria monocytogenes in a phosphate buffer (PB) was determined at different hypochlorite concentrations, pH values and temperatures. D-values, using a linear regression, of L. monocytogenes in PB (pH 6.5) were 23.54, 17.40, 14.24 and 12.00s at 5, 10, 50 and 100 mg l(-1) hypochlorite, respectively, at 30 degrees C. The k-values ranged from 0.098 to 0.192s(-1) and 0.007 to 0.018s(-1) for hypochlorite concentrations (from 5 to 100 mg l(-1)) in PB (pH 6.5) and PB containing 0.1% peptone (pH 6.5), respectively, at 30 degrees C. D-values of L. monocytogenes exposed to hypochlorite were decreased with decreasing pH of PB (pH from 8.5 to 4.5). Hypochlorite showed higher antimicrobial activity at higher temperature. Not only the effect of hypochlorite concentration on the inactivation of L. monocytogenes but also other parameters like temperature, pH and suspending solutions effect the inactivation rates.
Collapse
Affiliation(s)
- Osman Erkmen
- Department of Food Engineering, Faculty of Engineering, University of Gaziantep, 27310 Gaziantep, Turkey.
| |
Collapse
|
32
|
Park H, Hung YC, Chung D. Effects of chlorine and pH on efficacy of electrolyzed water for inactivating Escherichia coli O157:H7 and Listeria monocytogenes. Int J Food Microbiol 2004; 91:13-8. [PMID: 14967556 DOI: 10.1016/s0168-1605(03)00334-9] [Citation(s) in RCA: 112] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2002] [Revised: 04/12/2003] [Accepted: 05/19/2003] [Indexed: 11/29/2022]
Abstract
The effects of chlorine and pH on the bactericidal activity of electrolyzed (EO) water were examined against Escherichia coli O157:H7 and Listeria monocytogenes. The residual chlorine concentration of EO water ranged from 0.1 to 5.0 mg/l, and the pH effect was examined at pH 3.0, 5.0, and 7.0. The bactericidal activity of EO water increased with residual chlorine concentration for both pathogens, and complete inactivation was achieved at residual chlorine levels equal to or higher than 1.0 mg/l. The results showed that both pathogens are very sensitive to chlorine, and residual chlorine level of EO water should be maintained at 1.0 mg/l or higher for practical applications. For each residual chlorine level, bactericidal activity of EO water increased with decreasing pH for both pathogens. However, with sufficient residual chlorine (greater than 2 mg/l), EO water can be applied in a pH range between 2.6 (original pH of EO water) and 7.0 while still achieving complete inactivation of E. coli O157:H7 and L. monocytogenes.
Collapse
Affiliation(s)
- Hoon Park
- Department of Food Science and Technology, College of Agricultural and Environmental Sciences, University of Georgia, Griffin, GA 30223 1797, USA
| | | | | |
Collapse
|
33
|
Sanz S, Giménez M, Olarte C. Survival and growth of Listeria monocytogenes and enterohemorrhagic Escherichia coli O157:H7 in minimally processed artichokes. J Food Prot 2003; 66:2203-9. [PMID: 14672214 DOI: 10.4315/0362-028x-66.12.2203] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The ability of Listeria monocytogenes and Escherichia coli O157:H7 inoculated by immersion (at 4.6 and 5.5 log CFU/ g, respectively) to survive on artichokes during various stages of preparation was determined. Peeling, cutting, and disinfecting operations (immersion in 50 ppm of a free chlorine solution at 4 degrees C for 5 min) reduced populations of L. monocytogenes and E. coli O157:H7 by only 1.6 and 0.8 log units, respectively. An organic acid rinse (0.02% citric acid and 0.2% ascorbic acid) was more effective than a tap water rinse in removing these pathogens. Given the possibility of both pathogens being present on artichokes at the packaging stage, their behavior during the storage of minimally processed artichokes was investigated. For this purpose, batches of artichokes inoculated with L. monocytogenes or E. coli O157:H7 (at 5.5 and 5.2 log CFU/g, respectively) were packaged in P-Plus film bags and stored at 4 degrees C for 16 days. During this period, the equilibrium atmosphere composition and natural background microflora (mesophiles, psychrotrophs, anaerobes, and fecal coliforms) were also analyzed. For the two studied pathogens, the inoculum did not have any effect on the final atmospheric composition (10% O2, 13% CO2) or on the survival of the natural background microflora of the artichokes. L. monocytogenes was able to survive during the entire storage period in the inoculated batches, while the E. coli O157:H7 level increased by 1.5 log units in the inoculated batch during the storage period. The modified atmosphere was unable to control the behavior of either pathogen.
Collapse
Affiliation(s)
- Susana Sanz
- Area de Tecnología de los Alimentos, Departamento Agricultura y Alimentación, Universidad de La Rioja, C/Madre de Dios, 51 26006-Logroño, Spain.
| | | | | |
Collapse
|
34
|
Kwon NH, Kim SH, Kim JY, Lim JY, Kim JM, Jung WK, Park KT, Bae WK, Noh KM, Choi JW, Hur J, Park YH. Antimicrobial performance of alkaline ionic fluid (GC-100X) and its ability to remove Escherichia coli O157:H7 from the surface of tomatoes. J Food Prot 2003; 66:1604-10. [PMID: 14503713 DOI: 10.4315/0362-028x-66.9.1604] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
An efficacy test of GC-100X, a noncorrosive alkaline ionic fluid (pH 12) composed of free radicals and supplemented with xylitol, was carried out against six major foodborne pathogens-Staphylococcus aureus FRI 913, Salmonella enterica serovar Enteritidis ATCC 13076, S. enterica serovar Typhimurium DT104 Korean isolate, Vibrio parahaemolyticus ATCC 17803, Escherichia coli O157:H7 ATCC 43894, and Pseudomonas aeruginosa KCTC 1637-at three different temperatures (4, 25, and 36 degrees C) with or without organic load (2% yeast extract). Results revealed a more than 4-log10 (CFU/ml) reduction (1.0 x 10(4) CFU/ml reduction) against all pathogens reacted at 37 degrees C for 3 h in the absence of organic material. GC-100X solution diluted with an equal volume of distilled or standard hard water (300 ppm CaCO3) showed effective bactericidal activity, particularly against gram-negative bacteria. Washing efficacy of GC-100X solution was compared against E. coli O157:H7 on cherry tomato surfaces with those of a commercially used detergent and chlorine water (100 ppm). Viable cell counts of E. coli O157:H7 that had penetrated to the cores of tomatoes after sanitizing treatment revealed that GC-100X stock and its 5% diluted solutions had similar washing effects to 100-ppm chlorine water and were more effective than the other kitchen detergent. These results indicate that GC-100X has good bactericidal and sanitizing activities and is useful as a new sanitizer for food safety and kitchen hygiene.
Collapse
Affiliation(s)
- N H Kwon
- Department of Microbiology, College of Veterinary Medicine and School of Agricultural Biotechnology, Seoul National University, Shilim 9-Dong, Kwanak-Gu, Seoul, 151-742, Korea
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
35
|
McGee P, Bolton DJ, Sheridan JJ, Earley B, Kelly G, Leonard N. Survival of Escherichia coli O157:H7 in farm water: its role as a vector in the transmission of the organism within herds. J Appl Microbiol 2002; 93:706-13. [PMID: 12234355 DOI: 10.1046/j.1365-2672.2002.01752.x] [Citation(s) in RCA: 41] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
AIMS The study aimed to investigate the survival characteristics of Escherichia coli O157:H7 in farm water (FW), and in sterile distilled municipal water (SDW), stored outdoors under field conditions, with or without the addition of faeces (1% w/v), in a farmyard shed and the laboratory at 15 degrees C. METHODS AND RESULTS Water samples were inoculated with E. coli O157:H7 at 10(3) and 10(6) ml(-1), and sampled over a 31-day period. In FW stored outdoors in a field, E. coli O157:H7 survived for 14 days at temperatures <15 degrees C, at both inoculation levels, while in the laboratory at 15 degrees C, the organism was still detectable at low levels (<1 log10 cfu ml(-1)) after 31 days. The addition of bovine faeces to water outdoors (1% w/v) resulted in survival for 24 days. In SDW inoculated at 10(6) ml(-1) and stored in the laboratory (15 degrees C), only a 2.5 log reduction was observed after 31 days, while the organism could not be detected after 17 days in the field. Preliminary screening of water samples stored outdoors isolated a bacterium which exhibited antimicrobial activity towards E. coli O157:H7. CONCLUSIONS The survival of E. coli O157:H7 observed in this study illustrates the potential of farm water to act as a vehicle in the transfer of the organism across a herd. SIGNIFICANCE AND IMPACT OF THE STUDY The difficulty in extrapolating results from controlled laboratory situations to on-farm conditions is also highlighted in this study.
Collapse
Affiliation(s)
- P McGee
- Teagasc, The National Food Centre, Dublin, Ireland.
| | | | | | | | | | | |
Collapse
|
36
|
Park H, Hung YC, Kim C. Effectiveness of electrolyzed water as a sanitizer for treating different surfaces. J Food Prot 2002; 65:1276-80. [PMID: 12182480 DOI: 10.4315/0362-028x-65.8.1276] [Citation(s) in RCA: 95] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The effectiveness of electrolyzed (EO) water at killing Enterobacter aerogenes and Staphylococcus aureus in pure culture was evaluated. One milliliter (approximately 10(9) CFU/ml) of each bacterium was subjected to 9 ml of EO water or control water (EO water containing 10% neutralizing buffer) at room temperature for 30 s. Inactivation (reduction of > 9 log10 CFU/ ml) of both pathogens occurred within 30 s after exposure to EO water containing approximately 25 or 50 mg of residual chlorine per liter. The effectiveness of EO water in reducing E. aerogenes and S. aureus on different surfaces (glass, stainless steel, glazed ceramic tile, unglazed ceramic tile, and vitreous china) was also evaluated. After immersion of the tested surfaces in EO water for 5 min without agitation, populations of E. aerogenes and S. aureus were reduced by 2.2 to 2.4 log10 CFU/ cm2 and by 1.7 to 1.9 log10 CFU/cm2, respectively, whereas washing with control water resulted in a reduction of only 0.1 to 0.3 log10 CFU/cm2. The washing of tested surfaces in EO water with agitation (50 rpm) reduced populations of viable cells on the tested surfaces to < 1 CFU/cm2. For the control water treatment with agitation, the surviving numbers of both strains on the tested surfaces were approximately 3 log10 CFU/cm2. No viable cells of either strain were observed in the EO water after treatment, regardless of agitation. However, large populations of both pathogens were recovered from control wash solution after treatment.
Collapse
Affiliation(s)
- Hoon Park
- Department of Food Science and Technology, College of Agricultural and Environmental Sciences, University of Georgia, Griffin 30223-1797, USA
| | | | | |
Collapse
|