1
|
D'Alessandro C, Josic U, Mazzitelli C, Maravic T, Graham L, Barausse C, Mazzoni A, Breschi L, Blatz MB. Is zirconia surface etching a viable alternative to airborne particle abrasion? A systematic review and meta-analysis of in vitro studies. J Dent 2024; 151:105394. [PMID: 39374733 DOI: 10.1016/j.jdent.2024.105394] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2024] [Revised: 10/03/2024] [Accepted: 10/04/2024] [Indexed: 10/09/2024] Open
Abstract
OBJECTIVES This systematic review aimed to determine the effectiveness of various etching surface treatments on zirconia bond strength with the following research question: "Can zirconia etching serve as a viable alternative to airborne particle abrasion (APA) for achieving reliable bonding?". DATA In vitro studies comparing APA, performed with either conventional or silica-coated aluminum oxide (Al2O3) particles, with various etching protocols in terms of bonding performance were included. The risk of bias of the included studies was assessed using the QUIN's tool for in vitro studies. Meta-analyses were performed using RevMan; random-effects models were applied, and heterogeneity was tested using the I2 index. The significance level was set at p < 0.05. SOURCES A comprehensive literature search was conducted across electronic databases, including Clarivate Analytics' Web of Science, Cochrane Library, EMBASE, PubMed, Scopus and ProQuest. STUDY SELECTION Fifty-four relevant articles were included in this systematic review. According to the QUIN's tool, 7 studies were rated as "high risk of bias", 46 studies were rated as "medium risk", and 1 study was rated as "low risk". Nineteen studies were used for meta-analyses. Mostly, APA demonstrated significantly higher bond strength compared to various etching protocols (p < 0.05). However, no statistical difference was found between APA and high concentrations (40-48 %) of hydrofluoric acid (HF) in terms of immediate- and medium-term bond strength to resin composite (p > 0.05). On enamel, an experimental hot etching solution performed significantly better than APA in short-term follow-up (p < 0.05). A novel multi-acid solution exhibited significantly higher immediate shear bond strength to resin cement than APA (p < 0.05). Variable heterogeneity, ranging from low to high, was observed. CONCLUSIONS APA remains the surface treatment with the strongest evidence in the literature and it is usually more efficacious than zirconia etching. However, highly concentrated HF and an experimental hot etching solution have demonstrated similar or significantly higher bond strength values over time compared to APA, depending on the adhesive substrate. A recently introduced multi-acid solution (Zircos-E) needs to be further explored, especially in regards to long-term bond durability. CLINICAL SIGNIFICANCE This systematic review provides a comprehensive analysis of the existing in vitro evidence on the potential of zirconia etching and the bond durability of resin-based materials after artificial aging. Selecting appropriate surface treatment protocols is crucial for achieving optimal clinical outcomes.
Collapse
Affiliation(s)
- Carlo D'Alessandro
- Dental Clinic, Department of Biomedical and Neuromotor Science (DIBINEM), Alma Mater Studiorum - University of Bologna, Bologna, Italy
| | - Uros Josic
- Dental Clinic, Department of Biomedical and Neuromotor Science (DIBINEM), Alma Mater Studiorum - University of Bologna, Bologna, Italy
| | - Claudia Mazzitelli
- Dental Clinic, Department of Biomedical and Neuromotor Science (DIBINEM), Alma Mater Studiorum - University of Bologna, Bologna, Italy
| | - Tatjana Maravic
- Dental Clinic, Department of Biomedical and Neuromotor Science (DIBINEM), Alma Mater Studiorum - University of Bologna, Bologna, Italy
| | - Laurel Graham
- School of Dental Medicine, Levy Dental Medicine Library, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Carlo Barausse
- Dental Clinic, Department of Biomedical and Neuromotor Science (DIBINEM), Alma Mater Studiorum - University of Bologna, Bologna, Italy
| | - Annalisa Mazzoni
- Dental Clinic, Department of Biomedical and Neuromotor Science (DIBINEM), Alma Mater Studiorum - University of Bologna, Bologna, Italy
| | - Lorenzo Breschi
- Dental Clinic, Department of Biomedical and Neuromotor Science (DIBINEM), Alma Mater Studiorum - University of Bologna, Bologna, Italy
| | - Markus B Blatz
- School of Dental Medicine, Department of Preventive and Restorative Sciences, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
| |
Collapse
|
2
|
Gonçalves F, Ayala-Perez MD, Reis FCDS, Miranda-Júnior WG, Boaro LCC. Exploring Zirconia Adhesion: Pre and Postsintering Physical Surface Treatment, Chemical Treatment, and Cement Interactions. BIOMED RESEARCH INTERNATIONAL 2024; 2024:5394652. [PMID: 39220997 PMCID: PMC11362578 DOI: 10.1155/2024/5394652] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/15/2024] [Accepted: 07/31/2024] [Indexed: 09/04/2024]
Abstract
Background: Adhesion to zirconia remains a significant dental challenge. This study is aimed at assessing the bond strength of zirconia based on surface treatment with pre or postsintering sandblasting associated with different chemical treatments and resin cements. Methods: Zirconia blocks were divided into 12 experimental groups based on the surface treatment (presintering sandblasting or postsintering sandblasting/tribochemical abrasion treatment), chemical treatment (none, Single Bond Universal, or Signum Zirconia Bond), and choice of cement (Panavia F or RelyX™ U200). The bond strength was measured by shear tests using a universal testing machine. The fracture analysis was performed using stereomicroscopy. Data were analyzed using three-way ANOVA and Tukey's test (α = 5%). Results: Triple and double factor's interactions were not significant (p > 0.05). Regarding the surface treatment factor, the bond strength following postsintering sandblasting treatment associated with tribochemical abrasion (9.15 ± 3.62 MPa) was significantly higher than presintering sandblasting treatment (5.24 ± 3.53 MPa). Concerning the chemical treatment factor, bond strengths were ranked as follows: Signum Zirconia Bond > Single Bond Universal > no treatment. The bond strength of the resin cements did not differ among them. Most fractures (67%) were classified as adhesive, and 32% were categorized as mixed fractures. Conclusion: Surface treatment via postsintering sandblasting combined with tribochemical abrasion demonstrated superior efficacy than in presintering sandblasting. Additionally, chemical treatment with zirconia primer increased the bond strength of zirconia irrespective of the surface physical treatment.
Collapse
Affiliation(s)
- Flávia Gonçalves
- Faculdade de OdontologiaUniversidade Santo Amaro, Av. Prof. Eneas de Siqueira Neto, 340 04829-900, São Paulo, SP, Brazil
| | - Mirko Dennys Ayala-Perez
- Faculdade de OdontologiaUniversidade Santo Amaro, Av. Prof. Eneas de Siqueira Neto, 340 04829-900, São Paulo, SP, Brazil
| | | | - Walter Gomes Miranda-Júnior
- Departamento de Biomateriais e Biologia OralFaculdade de Odontologia da Universidade de São Paulo, Av. Prof. Lineu Prestes, 2222 05508-000, São Paulo, SP, Brazil
| | | |
Collapse
|
3
|
You GE, Lim MJ, Min KS, Yu MK, Lee KW. Surface property changes observed in zirconia during etching with high-concentration hydrofluoric acid over various immersion times. Dent Mater J 2024; 43:52-57. [PMID: 38044145 DOI: 10.4012/dmj.2023-091] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/05/2023]
Abstract
This study investigated the degree of phase transformation, surface roughness, and bond strength of zirconia immersed for various times in a 40% hydrofluoric acid (HF) solution. Non-etched sintered zirconia specimens were used as the control, while experimental groups were etched with a 40% HF solution for 5, 10, 20, 40, 80, 160 and 320 min. In each of the control and experimental groups, five specimens for X-ray diffraction analysis, four for surface morphology and surface roughness analysis, and ten for bonding strength measurement were used. As a result, the surface roughness of zirconia increased as the application time increased during the 40% HF etching, but the bond strength between zirconia and resin cement did not increase proportionally. The phase transformation from tetragonal to monoclinic also gradually increased with application time.
Collapse
Affiliation(s)
- Ga-Eul You
- Department of Conservative Dentistry, Jeonbuk National University School of Dentistry
| | - Myung-Jin Lim
- Department of Conservative Dentistry, Jeonbuk National University School of Dentistry
| | - Kyung-San Min
- Department of Conservative Dentistry, Jeonbuk National University School of Dentistry
- Research Institute of Clinical Medicine Jeonbuk National University-Biomedical Research Institute of Jeonbuk National University Hospital
| | - Mi-Kyung Yu
- Department of Conservative Dentistry, Jeonbuk National University School of Dentistry
- Research Institute of Clinical Medicine Jeonbuk National University-Biomedical Research Institute of Jeonbuk National University Hospital
| | - Kwang-Won Lee
- Department of Conservative Dentistry, Jeonbuk National University School of Dentistry
- Research Institute of Clinical Medicine Jeonbuk National University-Biomedical Research Institute of Jeonbuk National University Hospital
| |
Collapse
|
4
|
Rigos AE, Sarafidou K, Kontonasaki E. Zirconia bond strength durability following artificial aging: A systematic review and meta-analysis of in vitro studies. JAPANESE DENTAL SCIENCE REVIEW 2023; 59:138-159. [PMID: 37274447 PMCID: PMC10238491 DOI: 10.1016/j.jdsr.2023.04.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2022] [Revised: 03/27/2023] [Accepted: 04/19/2023] [Indexed: 06/06/2023] Open
Abstract
The present study systematically reviewed the literature regarding the bond strength durability of zirconia ceramics to resin-based luting cements after application of different bonding protocols and aging conditions. Electronic searches in PubMed, Scopus, and Web of Science databases were performed for relevant literature published between January 1st 2015 and November 15th 2022. Ninety-three (93) English language in-vitro studies were included. The percentage of the mean bond strength change was recorded prior to and after artificial aging, and the weighted mean values and 95% confidence intervals were calculated. Bonding protocols were classified based on the combination of MDP/non-MDP containing cement/primer and surface pretreatment, as well as the level of artificial aging performed. Alumina sandblasting (SA) was identified as the most frequently used surface pre-treatment while an insufficient number of studies was identified for each category of alternative surface treatments. The combination of MDP cement with tribochemical silica coating (TSC) or SA yielded more durable results after aging, while the application of SA and TSC improved bond durability when a non-MDP cement and a non-MDP primer were used. TSC may lead to increased bond durability compared to SA, whereas MDP cements may act similarly when combined with SA or TSC.
Collapse
Affiliation(s)
- Athanasios E. Rigos
- Resident, Graduate Prosthodontics, Texas A&M School of Dentistry, Dallas, TX, USA
| | - Katia Sarafidou
- Postdoctoral Researcher, Department of Prosthodontics, School of Dentistry, Faculty of Health Sciences, Aristotle University of Thessaloniki, Greece
| | - Eleana Kontonasaki
- Associate Professor, Department of Prosthodontics, School of Dentistry, Faculty of Health Sciences, Aristotle University of Thessaloniki, Greece
| |
Collapse
|
5
|
Wongsue S, Thanatvarakorn O, Prasansuttiporn T, Nimmanpipug P, Sastraruji T, Hosaka K, Foxton RM, Nakajima M. Effect of surface topography and wettability on shear bond strength of Y-TZP ceramic. Sci Rep 2023; 13:18249. [PMID: 37880480 PMCID: PMC10600127 DOI: 10.1038/s41598-023-45510-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2023] [Accepted: 10/20/2023] [Indexed: 10/27/2023] Open
Abstract
Zirconia ceramics have been widely used as dental restorations due to their esthetic appearance and high flexural strength. The bonding of zirconia with resin cement should rely on both mechanical and chemical bonds. This study was performed to investigate the effect of zirconia surface topography and its wettability after surface pretreatments on the microshear bond strength (μSBS) of a resin cement. Zirconia slabs were prepared and randomly divided into 5 groups based on the surface treatment as follows: no treatment (control), air abrasion (AB), etching with hydrofluoric acid (F), the mixture of hydrofluoric acid and nitric acid (FN), or the mixture of hydrochloric acid and nitric acid (CN) for 10 min. The specimens were subjected to investigation of surface roughness characteristics [average roughness (Ra), peak-to-valley average distance (Rpv), skewness (Rsk), and kurtosis (Rku)] using atomic force microscopy (AFM) and measurements of surface contact angle (θc) and μSBS of a resin cement. In addition, the area % of the nanoscale surface irregularity (nSI%) was calculated from the AFM images. The effects of nSI%, Ra and θc on the μSBS were analyzed by multiple linear regression analysis (p < 0.05). Multiple regression analysis revealed that the nSI% was the most predominant factor for the μSBS (p < 0.001). A surface with larger nSI%, higher Ra and relatively lower θc was essential for establishing a reliable resin-zirconia bond.
Collapse
Affiliation(s)
- Suriyakul Wongsue
- Dental Section, Buddhasothorn Hospital, Na Muang, Muang, 24000, Chachoengsao, Thailand
| | - Ornnicha Thanatvarakorn
- Faculty of Dentistry, Bangkokthonburi University, 16/10 Leab Klong Taweewatana Rd., Taweewatana, 10170, Bangkok, Thailand
| | - Taweesak Prasansuttiporn
- Department of Restorative Dentistry and Periodontology, Faculty of Dentistry, Chiang Mai University, Suthep, Muang Chiang Mai, 50200, Chiang Mai, Thailand.
| | - Piyarat Nimmanpipug
- Department of Chemistry, Faculty of Science, Chiang Mai University, Suthep, Muang Chiang Mai, 50200, Chiang Mai, Thailand
| | - Thanapat Sastraruji
- Dental Research Center, Faculty of Dentistry, Chiang Mai University, Suthep, Muang Chiang Mai, 50200, Chiang Mai, Thailand
| | - Keiichi Hosaka
- Department of Regenerative Dental Medicine, Graduate School of Biomedical Sciences, Tokushima University, 3-18-15, Kuramoto-cho, Tokushima, 770-8504, Japan
| | - Richard M Foxton
- King's College London Dental Institute, King's College London, Floor 25, London Bridge, London, SE1-9RT, UK
| | - Masatoshi Nakajima
- Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45, Yushima, Bunkyo-ku, Tokyo, 113-8549, Japan
| |
Collapse
|
6
|
Ribeiro RF, Oliveira DF, Tovani CB, Ramos AP, Borges AFS, Faria ACL, de Almeida RP, Rodrigues RCS. Y-TZP Physicochemical Properties Conditioned with ZrO 2 and SiO 2 Nanofilms and Bond Strength to Dual Resin Cement. MATERIALS (BASEL, SWITZERLAND) 2022; 15:7905. [PMID: 36431390 PMCID: PMC9694964 DOI: 10.3390/ma15227905] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 10/24/2022] [Accepted: 11/07/2022] [Indexed: 06/16/2023]
Abstract
Commercial Yttria-tetragonal zirconia polycrystalline (Y-TZP) was subjected to surface treatments, and the bond strength of dual resin cement to Y-TZP and failure modes were evaluated. Disks (12 mm × 2 mm), cylinders (7 mm × 3.3 mm), and bars (25 mm × 5 mm × 2 mm) were milled from Y-TZP CAD-CAM blocks, divided into seven groups, and subjected to different surface treatments; silicatization was used as control. On the basis of the literature, this study evaluated modifications with films containing SiO2 nanoparticles and silane; SiO2+ZrO2—SiO2 (50%) and ZrO2 (50%) nanoparticles, SiO2+ZrO2/Silane-SiO2 (50%) and ZrO2 (50%) nanoparticles, and silane. Specimens were analyzed by wettability (n = 3), surface free energy (n = 3), X-ray diffraction (n = 1), Fourier transform infrared spectroscopy (FTIR) (n = 1), roughness (n = 5), shear bond test (n = 10), and dynamic modulus (n = 3). Specimens treated with hydrofluoric acid—HF 40% presented significantly higher contact angle and lowest surface free energy (p < 0.05). The SiO2/Silane presented crystalline SiO2 on the surface. The surface roughness was significantly higher for groups treated with nanofilms (p < 0.05). Shear bond strength was significantly higher for silicatization, HF 40%/silicatization, SiO2/Silane, and SiO2+ZrO2/Silane groups. The proposed treatments with nanofilms had potentially good results without prejudice to the physicochemical characteristics of zirconia. Generally, groups that underwent silica surface deposition and silanization had better bond strength (p < 0.005).
Collapse
Affiliation(s)
- Ricardo Faria Ribeiro
- Department of Dental Materials and Prosthodontics, Ribeirao Preto School of Dentistry, University of Sao Paulo-FORP-USP, Ribeirao Preto 14040-904, SP, Brazil
| | - Danilo Flamini Oliveira
- Department of Dental Materials and Prosthodontics, Ribeirao Preto School of Dentistry, University of Sao Paulo-FORP-USP, Ribeirao Preto 14040-904, SP, Brazil
| | - Camila Bussola Tovani
- Department of Chemistry, Faculty of Philosophy, Sciences and Letters at Ribeirao Preto, University of Sao Paulo-FFCLRP-USP, Ribeirao Preto 14040-901, SP, Brazil
| | - Ana Paula Ramos
- Department of Chemistry, Faculty of Philosophy, Sciences and Letters at Ribeirao Preto, University of Sao Paulo-FFCLRP-USP, Ribeirao Preto 14040-901, SP, Brazil
| | - Ana Flavia Sanches Borges
- Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of Sao Paulo-FOB/USP, Bauru 17012-901, SP, Brazil
| | - Adriana Claudia Lapria Faria
- Department of Dental Materials and Prosthodontics, Ribeirao Preto School of Dentistry, University of Sao Paulo-FORP-USP, Ribeirao Preto 14040-904, SP, Brazil
| | - Rossana Pereira de Almeida
- Department of Dental Materials and Prosthodontics, Ribeirao Preto School of Dentistry, University of Sao Paulo-FORP-USP, Ribeirao Preto 14040-904, SP, Brazil
| | - Renata Cristina Silveira Rodrigues
- Department of Dental Materials and Prosthodontics, Ribeirao Preto School of Dentistry, University of Sao Paulo-FORP-USP, Ribeirao Preto 14040-904, SP, Brazil
| |
Collapse
|
7
|
Tang S, Wang Y, Zong Z, Ding N, Zhang Z. Enhanced osteogenic activity of titania-modified zirconia implant by ultraviolet irradiation. Front Bioeng Biotechnol 2022; 10:945869. [PMID: 36003530 PMCID: PMC9393212 DOI: 10.3389/fbioe.2022.945869] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Accepted: 07/12/2022] [Indexed: 11/13/2022] Open
Abstract
Zirconia is a superior implant material owing to its high mechanical strength, durable corrosion resistance, superior aesthetic effect and excellent biocompatibility. However, the bioactivity of zirconia surfaces remains a great challenge for implant osseointegration. A titania (TiO2) coating was innovatively synthesized on the surface of zirconia by infiltration in a suspension of zirconium oxychloride and titania for dense sintering. Subsequently, the coating was subjected to ultraviolet (UV) light to enhance the biological inertness of zirconia. Scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), X-ray diffraction (XRD) and contact angle analysis were conducted to confirm the surface characteristics. Afterwards, in vitro assessments of cell adhesion, proliferation and osteogenic differentiation of MC3T3-E1 cells were performed. Zirconia samples were implanted into rat femurs to assess biocompatibility and host tissue response in vivo. Micro-CT evaluation and histological testing were conducted. After UV irradiation, the content of hydroxyl groups and hydrophilicity of TiO2-modified zirconia were significantly increased. The results of in vitro experiments showed that TiO2-modified zirconia subjected to UV light could promote cell proliferation and spreading, enhance ALP activity and the degree of mineralization, and upregulate osteogenesis-related genes. Furthermore, in vivo assessments confirmed that UV-irradiated TiO2-modified zirconia implants maximized the promotion of osseointegration. TiO2-modified zirconia after UV treatment will have broad clinical application prospects in improving the osseointegration of zirconia implants.
Collapse
|
8
|
Adhesive Cementation of Zirconia Based Ceramics-Surface Modification Methods Literature Review. COATINGS 2022. [DOI: 10.3390/coatings12081067] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Introduction: The conditioning procedures for glass-based ceramic restorations before adhesive cementation are generally recognized. In the case of polycrystalline ceramics, which include zirconium oxide, there is still no standardized protocol. The aim of this work was to present conditioning methods of the cementation surface of zirconium oxide fixed dentures. The new generation high translucency zirconia has been also considered. Material and method: The following keywords for the PUBMED and EMBASE databases were used: zirconium oxide, zirconium oxide with increased translucency, bond strength, bending strength, surface treatment. The inclusion criteria were original papers in English published between 2015–2021. Results: Out of 1537 publications, 53 articles were selected for the study, covering methods of conditioning zirconium ceramics, including new materials with increased translucency. These procedures were divided into 5 main groups. Summary: Due to the widespread use of zirconia ceramics and the introduction of new zirconia-based materials, the use of a predictable and standardized cementation protocol is one of the most important factors contributing to the long-term clinical success of prosthetic restorations. Therefore, the research showed differences in the properties of the covered materials after conditioning. It suggests the need to create separate conditioning protocols for highly translucent and traditional zirconia.
Collapse
|