1
|
Yang J, Rosenmöller BRAM, van Riet TCT, Tan ML, Jamaludin FS, Ho JPTF, de Lange J. Smart mandibular advancement devices for obstructive sleep apnea: a systematic literature review. Sleep Breath 2024; 28:1879-1887. [PMID: 38886278 PMCID: PMC11449945 DOI: 10.1007/s11325-024-03068-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2024] [Revised: 05/05/2024] [Accepted: 05/22/2024] [Indexed: 06/20/2024]
Abstract
PURPOSE The goal of this review is to provide sleep physicians, dentists, and researchers with an evidence-based overview of the literature on smart mandibular advancement devices (MADs) for the treatment of obstructive sleep apnea. METHODS A systematic literature search was conducted by two blinded reviewers and an information specialist. A smart MAD was defined as any MAD with additional functionality besides mandibular protrusion. The bibliographic databases Medline, Embase, and Scopus were used to identify relevant publications. Studies were included if they described any stage of development of smart MADs. A total of 3162 titles and abstracts were screened for their relevance. In total, 58 articles were selected for full-text screening, 26 of which were included in this review. RESULTS The overall quality of the available literature was low. Most of the studies were observational, clinical or applied-research articles. The authors classified MADs into two main groups: passive and active. Passive MADs measured patient data, most commonly patient compliance. Active MADs adjusted protrusion of the mandible in response to patient data and were found in various phases of technological readiness (in development, demonstration, or deployment). CONCLUSION Innovations in smart mandibular advancement devices most frequently track patient compliance. Devices measuring other health parameters and active, feedback-controlled, devices are increasingly reported on. However, studies demonstrating their added benefit over traditional methods remain sparse. With further study, smart mandibular advancement devices have the potential to improve the efficiency of obstructive sleep apnea treatment and provide new treatment possibilities.
Collapse
Affiliation(s)
- Joshua Yang
- Harvard School of Dental Medicine, Boston, MA, USA
| | - Boudewijn R A M Rosenmöller
- Department of Oral and Maxillofacial Surgery, Amsterdam University Medical Centre, Academic Medical Center (AMC), and Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam, Meibergdreef 9, Amsterdam, 1105 AZ, The Netherlands.
- Department of Orofacial Pain and Dysfunction, Academic Centre for Dentistry Amsterdam (ACTA), Amsterdam, The Netherlands.
| | - Tom C T van Riet
- Department of Oral and Maxillofacial Surgery, Amsterdam University Medical Centre, Academic Medical Center (AMC), and Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam, Meibergdreef 9, Amsterdam, 1105 AZ, The Netherlands
| | - Misha L Tan
- Department of Oral and Maxillofacial Surgery, Amsterdam University Medical Centre, Academic Medical Center (AMC), and Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam, Meibergdreef 9, Amsterdam, 1105 AZ, The Netherlands
| | - Faridi S Jamaludin
- Information Specialist Medical Library, Amsterdam University Medical Centre, Academic Medical Center (AMC), Amsterdam, The Netherlands
| | - Jean-Pierre T F Ho
- Department of Oral and Maxillofacial Surgery, Amsterdam University Medical Centre, Academic Medical Center (AMC), and Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam, Meibergdreef 9, Amsterdam, 1105 AZ, The Netherlands
- Department of Oral and Maxillofacial Surgery, Northwest Clinics, Alkmaar, the Netherlands
| | - Jan de Lange
- Department of Oral and Maxillofacial Surgery, Amsterdam University Medical Centre, Academic Medical Center (AMC), and Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam, Meibergdreef 9, Amsterdam, 1105 AZ, The Netherlands
| |
Collapse
|
2
|
Bazoukis G, Bollepalli SC, Chung CT, Li X, Tse G, Bartley BL, Batool-Anwar S, Quan SF, Armoundas AA. Application of artificial intelligence in the diagnosis of sleep apnea. J Clin Sleep Med 2023; 19:1337-1363. [PMID: 36856067 PMCID: PMC10315608 DOI: 10.5664/jcsm.10532] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Revised: 02/21/2023] [Accepted: 02/21/2023] [Indexed: 03/02/2023]
Abstract
STUDY OBJECTIVES Machine learning (ML) models have been employed in the setting of sleep disorders. This review aims to summarize the existing data about the role of ML techniques in the diagnosis, classification, and treatment of sleep-related breathing disorders. METHODS A systematic search in Medline, EMBASE, and Cochrane databases through January 2022 was performed. RESULTS Our search strategy revealed 132 studies that were included in the systematic review. Existing data show that ML models have been successfully used for diagnostic purposes. Specifically, ML models showed good performance in diagnosing sleep apnea using easily obtained features from the electrocardiogram, pulse oximetry, and sound signals. Similarly, ML showed good performance for the classification of sleep apnea into obstructive and central categories, as well as predicting apnea severity. Existing data show promising results for the ML-based guided treatment of sleep apnea. Specifically, the prediction of outcomes following surgical treatment and optimization of continuous positive airway pressure therapy can be guided by ML models. CONCLUSIONS The adoption and implementation of ML in the field of sleep-related breathing disorders is promising. Advancements in wearable sensor technology and ML models can help clinicians predict, diagnose, and classify sleep apnea more accurately and efficiently. CITATION Bazoukis G, Bollepalli SC, Chung CT, et al. Application of artificial intelligence in the diagnosis of sleep apnea. J Clin Sleep Med. 2023;19(7):1337-1363.
Collapse
Affiliation(s)
- George Bazoukis
- Department of Cardiology, Larnaca General Hospital, Larnaca, Cyprus
- Department of Basic and Clinical Sciences, University of Nicosia Medical School, Nicosia, Cyprus
| | | | - Cheuk To Chung
- Cardiac Electrophysiology Unit, Cardiovascular Analytics Group, China-UK Collaboration, Hong Kong
| | - Xinmu Li
- Tianjin Key Laboratory of Ionic-Molecular Function of Cardiovascular disease, Department of Cardiology, Tianjin Institute of Cardiology, the Second Hospital of Tianjin Medical University, Tianjin, China
| | - Gary Tse
- Cardiac Electrophysiology Unit, Cardiovascular Analytics Group, China-UK Collaboration, Hong Kong
- Kent and Medway Medical School, Canterbury, Kent, United Kingdom
| | - Bethany L. Bartley
- Division of Sleep and Circadian Disorders, Brigham and Women’s Hospital, Boston, Massachusetts
| | - Salma Batool-Anwar
- Division of Sleep and Circadian Disorders, Brigham and Women’s Hospital, Boston, Massachusetts
| | - Stuart F. Quan
- Division of Sleep and Circadian Disorders, Brigham and Women’s Hospital, Boston, Massachusetts
- Asthma and Airway Disease Research Center, University of Arizona College of Medicine, Tucson, Arizona
| | - Antonis A. Armoundas
- Cardiovascular Research Center, Massachusetts General Hospital, Boston, Massachusetts
- Broad Institute, Massachusetts Institute of Technology, Cambridge, Massachusetts
| |
Collapse
|
3
|
Mosca EV, Bruehlmann S, Zouboules SM, Chiew AE, Westersund C, Hambrook DA, Jahromi SAZ, Grosse J, Topor ZL, Charkhandeh S, Remmers JE. In-home mandibular repositioning during sleep using MATRx plus predicts outcome and efficacious positioning for oral appliance treatment of obstructive sleep apnea. J Clin Sleep Med 2022; 18:911-919. [PMID: 34747691 PMCID: PMC8883079 DOI: 10.5664/jcsm.9758] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
STUDY OBJECTIVES Oral appliance therapy is not commonly used to treat obstructive sleep apnea due to inconsistent efficacy and lack of established configuration procedures. Both problems may be overcome by information gathered while repositioning the mandible during sleep. The purpose of this investigation was to determine if an unattended sleep study with a mandibular positioner can predict therapeutic success and efficacious mandibular position, assess the contribution of artificial intelligence analytics to such a system, and evaluate symptom resolution using an objective titration approach. METHODS Fifty-eight individuals with obstructive sleep apnea underwent an unattended sleep study with an auto-adjusting mandibular positioner followed by fitting of a custom oral appliance. Therapeutic outcome was assessed by the 4% oxygen desaturation index with therapeutic success defined as oxygen desaturation index < 10 h-1. Outcome was prospectively predicted by an artificial intelligence system and a heuristic, rule-based method. An efficacious mandibular position was also prospectively predicted by the test. Data on obstructive sleep apnea symptom resolution were collected 6 months following initiation of oral appliance therapy. RESULTS The artificial intelligence method had significantly higher predictive accuracy (sensitivity: 0.91, specificity: 1.00) than the heuristic method (P = .016). The predicted efficacious mandibular position was associated with therapeutic success in 83% of responders. Appliances titrated based on oxygen desaturation index effectively resolved obstructive sleep apnea symptoms. CONCLUSIONS The MATRx plus device provides an accurate means for predicting outcome to oral appliance therapy in the home environment and offers a replacement to blind titration of oral appliances. CLINICAL TRIAL REGISTRATION Registry: ClinicalTrials.gov; Name: Predictive Accuracy of MATRx plus in Identifying Favorable Candidates for Oral Appliance Therapy; Identifier: NCT03217383; URL: https://clinicaltrials.gov/ct2/show/NCT03217383. CITATION Mosca EV, Bruehlmann S, Zouboules SM, et al. In-home mandibular repositioning during sleep using MATRx plus predicts outcome and efficacious positioning for oral appliance treatment of obstructive sleep apnea. J Clin Sleep Med. 2022;18(3):911-919.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | - Zbigniew L. Topor
- Zephyr Sleep Technologies, Calgary, Canada,University of Calgary, Calgary, Canada
| | | | - John E. Remmers
- Zephyr Sleep Technologies, Calgary, Canada,University of Calgary, Calgary, Canada,Address correspondence to: John Remmers, MD, Chief Medical Officer, Zephyr Sleep Technologies Inc., #102, 701 64 Ave SE, Calgary, AB, Canada;
| |
Collapse
|
4
|
A pilot study on comparison of subjective titration versus remotely controlled mandibular positioning during polysomnography and drug-induced sleep endoscopy, to determine the effective protrusive position for mandibular advancement device therapy. Sleep Breath 2022; 26:1837-1845. [PMID: 35064876 PMCID: PMC9663400 DOI: 10.1007/s11325-022-02569-3] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Revised: 12/24/2021] [Accepted: 01/05/2022] [Indexed: 11/29/2022]
Abstract
Study objectives The aim of this pilot study was to evaluate the clinical effectiveness of subjective titration versus objectively guided titration during polysomnography (PSG) and drug-induced sleep endoscopy (DISE) in mandibular advancement device (MAD) therapy for patients with obstructive sleep apnea (OSA). Methods In this pilot cross-over study, patients underwent three titration procedures in randomized order: (1) subjective titration, (2) PSG-guided titration using a remotely controlled mandibular positioner (RCMP) and (3) DISE-assisted titration using RCMP. After each titration procedure, patients used the MAD for 1 month at the targeted protrusion obtained according to the preceding titration procedure. For each procedure, a follow-up PSG was performed after 1 month of MAD use in order to evaluate the efficacy of the MAD. Results Ten patients were included in the study. Overall, no significant differences in targeted optimal protrusion compared to maximal comfortable protrusion among the three titration methods were observed. There was no significant difference in reduction in AHI. In this study, PSG titration correctly classified 50% of patients as ‘responder’. A higher predictive accuracy was found for DISE titration with a sensitivity of 83.3% and a specificity of 100%. Conclusions This pilot randomized cross-over trial showed no differences in optimal mandibular positioning and corresponding efficacy of MAD between subjective titration, DISE titration or PSG titration.
Collapse
|
5
|
Mohammadieh AM, Sutherland K, Chan ASL, Cistulli PA. Mandibular Advancement Splint Therapy. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2022; 1384:373-385. [PMID: 36217096 DOI: 10.1007/978-3-031-06413-5_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Mandibular advancement splint (MAS) therapy is the leading alternative to continuous positive airway pressure (CPAP) therapy for the treatment of obstructive sleep apnoea. A MAS is an oral appliance which advances the mandible in relation to the maxilla, thus increasing airway calibre and reducing collapsibility. Although it is less effective than CPAP in reducing the apnoea-hypopnoea index (AHI), it has demonstrated equivalence to CPAP in a number of key neurobehavioural and cardiovascular health outcomes, perhaps due to increased tolerability and patient adherence when compared to CPAP. However, response to MAS is variable, and reliable prediction tools for patients who respond best to MAS therapy have thus far been elusive; this is one of the key clinical barriers to wider uptake of MAS therapy. In addition, the most effective MAS devices are custom-made by a dentist specialising in the treatment of sleep disorders, which may present financial or accessibility barriers for some patients. MAS devices are generally well tolerated but may have side effects including temporomandibular joint (TMJ) dysfunction, hypersalivation, tooth pain and migration as well as occlusal changes. A patient-centred approach to treatment from a multidisciplinary team perspective is recommended. Evidence-based clinical practice points and areas of future research are summarised at the conclusion of the chapter.
Collapse
Affiliation(s)
- Anna M Mohammadieh
- Department of Respiratory & Sleep Medicine, Royal North Shore Hospital, St Leonards, NSW, Australia.
- Sleep Research Group, Charles Perkins Centre, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, Australia.
- Faculty of Medicine and Health, Northern Clinical School, The University of Sydney, Sydney, NSW, Australia.
| | - Kate Sutherland
- Department of Respiratory & Sleep Medicine, Royal North Shore Hospital, St Leonards, NSW, Australia
- Sleep Research Group, Charles Perkins Centre, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, Australia
- Faculty of Medicine and Health, Northern Clinical School, The University of Sydney, Sydney, NSW, Australia
| | - Andrew S L Chan
- Department of Respiratory & Sleep Medicine, Royal North Shore Hospital, St Leonards, NSW, Australia
- Faculty of Medicine and Health, Northern Clinical School, The University of Sydney, Sydney, NSW, Australia
| | - Peter A Cistulli
- Department of Respiratory & Sleep Medicine, Royal North Shore Hospital, St Leonards, NSW, Australia
- Sleep Research Group, Charles Perkins Centre, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, Australia
- Faculty of Medicine and Health, Northern Clinical School, The University of Sydney, Sydney, NSW, Australia
| |
Collapse
|
6
|
Pae EK, Harper RM. Elevated Hyoid Bone Position in Response to Mandibular Advancing Appliance Predicts Effectiveness of the Appliance for Obstructive Sleep Apnea. FRONTIERS IN DENTAL MEDICINE 2021. [DOI: 10.3389/fdmed.2021.672936] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] Open
Abstract
The objective was to determine whether hyoid bone elevation induced by an anterior mandibular positioning appliance (AMP) predicts the effectiveness of the AMP in patients with obstructive sleep apnea (OSA). Fifteen patients (12 males and 3 females) underwent polysomnographic recordings and lateral cephalograms before and after AMP use of at least 6 months. Measurements of sleep variables and upper airway morphology were compared between pre-AMP and with-AMP states. The AMP appliance reduced apnea-hypopnea indices (AHI) ~53% (33.77 ± 3.29 vs. 15.85 ± 3.78, P = 0.0013). Cephalograms of the oropharyngeal airway showed that the hyoid bone moved superiorly toward the inferior mandibular border (Δ H-MP) ~5 mm (23.4 ± 1.44 vs. 18.27 ± 1.86, P = 0.0377), with the AMP inserted in the oral cavity; no airway measurement other than hyoid bone position changed. No significant correlations emerged between AHI improvement (Δ AHI) and amounts of hyoid elevation (Δ H-MP) when all patients were pooled. However, when the samples were subcategorized, the correlation coefficients increased significantly (P < 0.01) in both subgroups. This outcome suggests the presence of two distinct types among the “Good-Responders” to AMP appliance use. Overall use of the AMP appliance is effective; however, the effectiveness of the appliance appears to depend on the mode of hyoid elevations, likely resulting from muscle responsiveness in patients with AMP use. The results suggest that Δ H-MP measurements may be a useful marker to segregate patients with tongue and hyoid muscles responsive to AMP from those not-so-responsive.
Collapse
|
7
|
Stern J, Lee K, Kuhns D, Martinez-Kratz JF. Efficacy and Effectiveness of the ProSomnus® [IA] Sleep Device for the Treatment of Obstructive Sleep Apnea: EFFECTS Study. Cureus 2021; 13:e15391. [PMID: 34249542 PMCID: PMC8252976 DOI: 10.7759/cureus.15391] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/02/2021] [Indexed: 12/04/2022] Open
Abstract
Objectives To evaluate the effectiveness of a new mandibular advancement device (MAD) (Prosomnus® [IA] Sleep Device, Prosomnus Sleep Technologies, Pleasanton CA) fitted with a compliance tracker as a first-line treatment in a population of patients with mild to severe obstructive sleep apnea (OSA). Methods Treatment effectiveness was measured using pre and post-treatment home sleep testing (HST) and validated sleep and quality of life questionnaires. Mean disease alleviation (MDA) was calculated to compare the treatment effectiveness of MAD to historical continuous positive airway pressure (CPAP) effectiveness data. Results MAD was found to be an effective first-line treatment for patients with mild, moderate, and severe sleep apnea with excellent compliance rates, similar to or better than CPAP, and an equal or better MDA of 56.7% compared to literature values of 50% for CPAP. Conclusions MAD should be considered an effective first-line treatment for patients with mild and moderate sleep apnea and for severe sleep apnea for patients who prefer, refuse, or are not candidates for CPAP.
Collapse
Affiliation(s)
- Jordan Stern
- Otolaryngology, Icahn School of Medicine at Mount Sinai, New York, USA
- Sleep Medicine, BlueSleep, New York, USA
| | | | - Dave Kuhns
- Sleep Apnea, ProSomnus Sleep Technologies, Pleasanton, USA
| | | |
Collapse
|
8
|
A Phenotypic Approach for Personalised Management of Obstructive Sleep Apnoea. CURRENT OTORHINOLARYNGOLOGY REPORTS 2021. [DOI: 10.1007/s40136-021-00346-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
9
|
The acoustical and perceptual features of snore-related sounds in patients with obstructive sleep apnea sleeping with the dynamic mandibular advancement system MATRx plus®. Sleep Breath 2021; 26:215-224. [PMID: 33956293 DOI: 10.1007/s11325-021-02392-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2020] [Revised: 04/20/2021] [Accepted: 04/28/2021] [Indexed: 10/21/2022]
Abstract
PURPOSE The effect of snoring on the bed partner can be studied through the evaluation of in situ sound records by the bed partner or unspecialized raters as a proxy of real-life snoring perception. The aim was to characterize perceptual snore events through acoustical features in patients with obstructive sleep apnea (OSA) with an advanced mandibular position. METHODS Thirty-minute sound samples of 29 patients with OSA were retrieved from overnight, in-home recordings of a study to validate the MATRx plus® dynamic mandibular advancement system. Three unspecialized raters identified sound events and classified them as noise, snore, or breathing. The raters provided ratings for classification certainty and annoyance. Data were analyzed with respect to respiratory phases, and annoyance. RESULTS When subdividing perceptual events based on respiratory phase, the logarithm-transformed Mean Power, Spectral Centroid, and Snore Factor differed significantly between event types, although not substantially for the spectral centroid. The variability within event type was high and distributions suggested the presence of subpopulations. The general linear model (GLM) showed a significant patient effect. Inspiration segments occurred in 65% of snore events, expiration segments in 54%. The annoyance correlated with the logarithm of mean power (r = 0.48) and the Snore Factor (0.46). CONCLUSION Perceptual sound events identified by non-experts contain a non-negligible mixture of expiration and inspiration phases making the characterization through acoustical features complex. The present study reveals that subpopulations may exist, and patient-specific features need to be introduced.
Collapse
|
10
|
De Meyer MMD, Jahromi SAZ, Hambrook DA, Remmers JE, Marks LAM, Jacquet W. Perceptual snoring as a basis for a psychoacoustical modeling and clinical patient profiling. Sleep Breath 2021; 26:75-80. [PMID: 33797031 DOI: 10.1007/s11325-021-02348-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2020] [Revised: 03/04/2021] [Accepted: 03/09/2021] [Indexed: 11/30/2022]
Abstract
PURPOSE The perceptual burden and social nuisance for mainly the co-sleeper can affect the relationship between snorer and bedpartner. Mandibular advancement devices (MAD) are commonly recommended to treat sleep-related breathing such as snoring or sleep apnea. There is no consensus about the definition of snoring particularly with MAD, which is essential for assessing the effectiveness of treatment. We aimed to stablish a notion of perceptual snoring with MAD in place. METHODS Sound samples, each 30 min long, were recorded during in-home, overnight, automatic mandibular repositioning titration studies in a population of 29 patients with obstructive sleep apnea syndrome (OSAS) from a clinical trial carried out to validate the MATRx plus. Three unspecialized and calibrated raters identified sound events and classified them as noise, snore, or breathing as well as providing scores for classification certainty and annoyance. Data were analyzed with respect to expiration-inspiration, duration, annoyance, and classification certainty. RESULTS A Fleiss' kappa (>0.80) and correlation duration of events (>0.90) between raters were observed. Prevalence of all breath sounds: snore 55.6% (N = 6398), breathing sounds 31.7% (N = 3652), and noise 9.3% (N = 1072). Inspiration occurs in 88.3% of events, 96.8% contained at least on expiration phase. Snore and breath events had similar duration, respectively 2.58s (sd 1.43) and 2.41s (sd 1.22). Annoyance is lowest for breathing events (8.00 sd 0.98) and highest for snore events (4.90 sd 1.92) on a VAS from zero to ten. CONCLUSION Perceptual sound events can be a basis for analysis in a psychosocial context. Perceived snoring occurs during both expiration as well as inspiration. Substantial amount of snoring remains despite repositioning of the mandible aimed at the reduction of AHI-ODI.
Collapse
Affiliation(s)
- Micheline M D De Meyer
- Oral Health in Special Needs, Sleep Breathing Disorders, Oral Health Sciences, Ghent University Hospital, Gent, Belgium. .,Department of Dentistry, Radboud University Medical Center and Radboud Institute for Health Sciences, Nijmegen, The Netherlands. .,Department of Pneumology, UZ Brussels, Brussels, Belgium.
| | | | | | | | - Luc A M Marks
- Special Care in Dentistry, Oral Health Sciences, Ghent University Hospital, Gent, Belgium.,Center for Dentistry and Oral hygiene, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Wolfgang Jacquet
- Department of Surgical Clinical Sciences CHIR-ORHE, Faculty of Medicine and Pharmacy, Vrije Universiteit Brussel, Brussels, Belgium.,Department of Educational Sciences EDWE-LOCI, Faculty of Psychology and Educational Sciences, Vrije Universiteit Brussel, Brussels, Belgium
| |
Collapse
|
11
|
Levendowski DJ, Olmstead R, Sall E, Westbrook PR, Beine B, Munafo D. Criteria for oral appliance and/or supine avoidance therapy selection based on outcome optimization and cost-effectiveness. J Med Econ 2021; 24:757-763. [PMID: 33990168 DOI: 10.1080/13696998.2021.1930549] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
AIM Produce empirical support for further enhancements to a therapy selection protocol for obstructive sleep apnea (OSA) patients intolerant of positive airway pressure. METHODS A retrospective analysis was conducted in 101 men and 69 women patients. Two-night home sleep apnea studies were conducted at baseline and with a trial oral appliance. Twenty-minutes in-position sleep was required to compute supine and non-supine apnea-hypopnea indexes (AHI). Data analyses were applied after stratification by sex and response to oral appliance therapy (OAT), and the results used for to calculate incremental cost-effectiveness ratios (ICER). RESULTS Compared with men, women had significantly lower pre-treatment supine and non-supine AHI values (p < .05). OAT non-responders had higher non-supine AHIs, resulting in less positional-OSA and more cases with severe OSA (p < .05). Across the cohort, 21% had positional-OSA with a pre-treatment non-supine AHI < 5 events/h. In those who met this criterion, supine avoidance therapy (SAT) could have reduced the AHI values more than OAT by an average of 33% (p < .0001). The ICER for SAT instead of OAT in this group was negative, a condition that only occurs when one therapy is both less expensive and more effective than the other. A greater proportion of non-responders had post-OAT overall AHI ≥ 10 events/h with residual positional-OSA compared with responders (p < .0001). Combination therapy could reduce the AHI values by an average of 68%, resulting in ICER estimates five-times less than the reimbursement decision-making threshold. CONCLUSIONS AND LIMITATIONS Based on pre-treatment non-supine AHI values, SAT would provide a superior first-line treatment outcome as compared to OAT in 21% of patients diagnosed with OSA. SAT would also provide a cost-effective adjuvant to OAT in an additional 15% of cases. The benefit of SAT could not be determined in one-fifth of the cohort who slept exclusively supine.
Collapse
Affiliation(s)
| | - Richard Olmstead
- Semel Institute for Neuroscience and Human Behavior, Department of Psychiatry and Biobehavioral Sciences, David Geffen School of Medicine, University of California, Los Angeles, CA, USA
| | - Edward Sall
- Sleep Alliance, BetterNight Medical Group, Inc, San Diego, CA, USA
| | - Philip R Westbrook
- Sleep and Respiratory, Advanced Brain Monitoring, Inc, Carlsbad, CA, USA
| | | | | |
Collapse
|
12
|
Mehta N. Now what? Where do we go from here? Cranio 2020; 39:4. [PMID: 33357139 DOI: 10.1080/08869634.2020.1849975] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Affiliation(s)
- Noshir Mehta
- Sleep Editor, CRANIO, Tufts Craniofacial Pain Center , Boston, MA, USA.,
| |
Collapse
|
13
|
Herrero Babiloni A, Beetz G, Dal Fabbro C, Martel MO, Huynh N, Masse JF, Sessle B, Lavigne GJ. Dental sleep medicine: Time to incorporate sleep apnoea education in the dental curriculum. EUROPEAN JOURNAL OF DENTAL EDUCATION : OFFICIAL JOURNAL OF THE ASSOCIATION FOR DENTAL EDUCATION IN EUROPE 2020; 24:605-610. [PMID: 32320121 DOI: 10.1111/eje.12533] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/06/2020] [Revised: 02/10/2020] [Accepted: 04/17/2020] [Indexed: 06/11/2023]
Abstract
Dental sleep medicine is a discipline that includes conditions such as sleep breathing disorders (eg snoring and sleep apnoea), sleep bruxism, orofacial pain and sleep-related complaints, and to some extent gastro-oesophageal reflux disorder and/or insomnia. Obstructive sleep apnoea (OSA) is a life-threatening condition that dentists need to identify and manage when indicated in order to increase patient well-being and to be taken in consideration in the dental curriculum. The main objective of this paper is to highlight the relevance of dental sleep medicine in the context of dental education, and to discuss potential educational content for integration in the dental curriculum with a focus on OSA, a condition that is not yet integrated in many dental training curricula around the world.
Collapse
Affiliation(s)
- Alberto Herrero Babiloni
- Sacré-Coeur Hospital, University of Montreal, Montreal, QC, Canada
- Faculty of Dental Medicine, University of Montreal, Montreal, QC, Canada
- Division of Experimental Medicine, McGill University, Montreal, QC, Canada
| | - Gabrielle Beetz
- Sacré-Coeur Hospital, University of Montreal, Montreal, QC, Canada
| | | | - Marc O Martel
- Division of Experimental Medicine, McGill University, Montreal, QC, Canada
- Faculty of Dentistry & Department of Anesthesia, McGill University, Montreal, QC, Canada
| | - Nelly Huynh
- Faculty of Dental Medicine, University of Montreal, Montreal, QC, Canada
| | | | - Barry Sessle
- Faculty of Medicine, Faculty of Dentistry and Department of Physiology, University of Toronto, Toronto, ON, Canada
| | - Gilles J Lavigne
- Sacré-Coeur Hospital, University of Montreal, Montreal, QC, Canada
- Faculty of Dental Medicine, University of Montreal, Montreal, QC, Canada
- Division of Experimental Medicine, McGill University, Montreal, QC, Canada
| |
Collapse
|
14
|
Sutherland K, Cistulli PA. Oral Appliance Therapy for Obstructive Sleep Apnoea: State of the Art. J Clin Med 2019; 8:jcm8122121. [PMID: 31810332 PMCID: PMC6947472 DOI: 10.3390/jcm8122121] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2019] [Revised: 11/26/2019] [Accepted: 11/27/2019] [Indexed: 12/17/2022] Open
Abstract
Obstructive sleep apnoea (OSA) represents a significant global health burden, with impact on cardiometabolic health, chronic disease, productivity loss and accident risk. Oral appliances (OA) are an effective therapy for OSA and work by enlarging and stabilising the pharyngeal airway to prevent breathing obstructions during sleep. Although recommended in clinical guidelines for OSA therapy, they are often considered only as second-line therapy following positive airway pressure (PAP) therapy failure. There has been a long-standing barrier to selecting OA over PAP therapy due to the inability to be certain about the level of efficacy in individual OSA patients. A range of methods to select OSA patients for OA therapy, based on the outcome of a single sleep study night, have been proposed, although none has been widely validated for clinical use. Emergent health outcome data suggest that equivalent apnoea–hypopnea index reduction may not be necessary to produce the same health benefits of PAP. This may be related to the more favourable adherence to OA therapy, which can now be objectively verified. Data on longer term health outcomes are needed, and there are additional opportunities for device improvement and combination therapy approaches. OAs have an important role in precision care of OSA as a chronic disorder through a multi-disciplinary care team. Future studies on real-world health outcomes following OA therapy are needed.
Collapse
Affiliation(s)
- Kate Sutherland
- Sleep Research Group, Charles Perkins Centre and Northern Clinical School, Faculty of Medicine and Health, University of Sydney, Sydney, NSW 2006, Australia;
- Department of Respiratory Medicine, Royal North Shore Hospital, Sydney, NSW 2065, Australia
- Correspondence:
| | - Peter A. Cistulli
- Sleep Research Group, Charles Perkins Centre and Northern Clinical School, Faculty of Medicine and Health, University of Sydney, Sydney, NSW 2006, Australia;
- Department of Respiratory Medicine, Royal North Shore Hospital, Sydney, NSW 2065, Australia
| |
Collapse
|
15
|
Viviano J, Klauer D, Olmos S, Viviano JD. Retrospective comparison of the George Gauge™ registration and the sibilant phoneme registration for constructing OSA oral appliances. Cranio 2019; 40:5-13. [PMID: 31770076 DOI: 10.1080/08869634.2019.1694776] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
Objective: To compare outcomes for appliances manufactured utilizing the George Gauge™ Registration (GGR) and the Sibilant Phoneme Registration (SPR). It was hypothesized that there would be no difference in outcomes.Methods: This study is a retrospective analysis of two groups. Each group consisted of 20 oral appliances manufactured utilizing the GGR and 20 utilizing the SPR.Results: For the two-site data, no difference in outcomes was demonstrated (p = .24). The SPR method required fewer calibrations (p = 5.6 × 10-3) and less jaw movement (p = 3.33 × 10-4). Both bite methods resulted in similarly variable post-AHI scores (p = .52). For the eight-site data, no difference in outcomes was demonstrated (p = .76). The SPR required less movement of the jaw (p = 4.52 × 10-5); however, outcome variance was larger for the SPR (p = .036).Conclusion: The study null hypothesis of no difference in outcomes was supported.Abbreviations: AHI: Apnea-Hypopnea Index; GGR: George Gauge Registration; SPR: Sibilant Phoneme Registration; OSA: Obstructive Sleep Apnea; OA: Oral Appliance; OAT: Oral Appliance Therapy; MA: Mandibular Advancement; VDO: Vertical Dimensional Opening; AADSM: American Academy of Dental Sleep Medicine; ABDSM: American Board of Dental Sleep Medicine; BMI: Body Mass Index.
Collapse
Affiliation(s)
- John Viviano
- Private Practice, Sleep Disorders Dentistry RLC, Mississauga, ON, Canada
| | | | | | - Joseph D Viviano
- Private Practice, Sleep Disorders Dentistry RLC, Mississauga, ON, Canada
| |
Collapse
|
16
|
Dieltjens M, Vanderveken OM. Oral Appliances in Obstructive Sleep Apnea. Healthcare (Basel) 2019; 7:healthcare7040141. [PMID: 31717429 PMCID: PMC6956298 DOI: 10.3390/healthcare7040141] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2019] [Revised: 10/29/2019] [Accepted: 11/01/2019] [Indexed: 12/25/2022] Open
Abstract
Oral appliance therapy is increasingly prescribed as a non-invasive treatment option for patients diagnosed with obstructive sleep apnea. The custom-made titratable mandibular advancement devices (MAD) are the recommended type of oral appliances. Mandibular advancement devices are efficacious in reducing the severity of obstructive sleep apnea, however, only to a lesser extent than standard therapy using continuous positive airway pressure (CPAP). Although oral appliance therapy is known to reduce the severity of obstructive sleep apnea in most of the patients, one out of three patients still show negligible improvement under MAD therapy. Therefore, the selection of the appropriate candidates for this therapy is imperative and several upfront prediction tools are described. Overall, the health outcome of mandibular advancement device therapy is similar to that of CPAP, probably due to the inferior compliance of CPAP compared to MAD therapy, resulting in similar clinical effectiveness.
Collapse
Affiliation(s)
- Marijke Dieltjens
- Department of Translational neurosciences, Faculty of Medicine and Health Sciences, University of Antwerp, 2610 Wilrijk, Belgium;
- Special Dentistry Care, Antwerp University Hospital, 2650 Edegem, Belgium
- ENT, Head and Neck Surgery, Antwerp University Hospital, 2650 Edegem, Belgium
| | - Olivier M. Vanderveken
- Department of Translational neurosciences, Faculty of Medicine and Health Sciences, University of Antwerp, 2610 Wilrijk, Belgium;
- ENT, Head and Neck Surgery, Antwerp University Hospital, 2650 Edegem, Belgium
- Multidisciplinary Sleep Disorders Centre, Antwerp University Hospital, 2650 Edegem, Belgium
- Correspondence:
| |
Collapse
|
17
|
Lavigne G, Herrero Babiloni A, Beetz G, Dal Fabbro C, Sutherland K, Huynh N, Cistulli P. Critical Issues in Dental and Medical Management of Obstructive Sleep Apnea. J Dent Res 2019; 99:26-35. [DOI: 10.1177/0022034519885644] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
This critical review focuses on obstructive sleep apnea (OSA) and its management from a dental medicine perspective. OSA is characterized by ≥10-s cessation of breathing (apnea) or reduction in airflow (hypopnea) ≥5 times per hour with a drop in oxygen and/or rise in carbon dioxide. It can be associated with sleepiness and fatigue, impaired mood and cognition, cardiometabolic complications, and risk for transportation and work accidents. Although sleep apnea is diagnosed by a sleep physician, its management is interdisciplinary. The dentist’s role includes 1) screening patients for OSA risk factors (e.g., retrognathia, high arched palate, enlarged tonsils or tongue, enlarged tori, high Mallampati score, poor sleep, supine sleep position, obesity, hypertension, morning headache or orofacial pain, bruxism); 2) referring to an appropriate health professional as indicated; and 3) providing oral appliance therapy followed by regular dental and sleep medical follow-up. In addition to the device features and provider expertise, anatomic, behavioral, demographic, and neurophysiologic characteristics can influence oral appliance effectiveness in managing OSA. Therefore, OSA treatment should be tailored to each patient individually. This review highlights some of the putative action mechanisms related to oral appliance effectiveness and proposes future research directions.
Collapse
Affiliation(s)
- G.J. Lavigne
- Faculté de médicine dentaire, Université de Montréal, Montréal, Canada
- Research Center, CIUSSS du Nord-de-l’Île-de-Montréal, Montréal, Canada
- Division of Experimental Medicine, McGill University, Montréal, Canada
| | - A. Herrero Babiloni
- Faculté de médicine dentaire, Université de Montréal, Montréal, Canada
- Research Center, CIUSSS du Nord-de-l’Île-de-Montréal, Montréal, Canada
- Division of Experimental Medicine, McGill University, Montréal, Canada
| | - G. Beetz
- Research Center, CIUSSS du Nord-de-l’Île-de-Montréal, Montréal, Canada
| | | | - K. Sutherland
- Charles Perkins Centre and Sydney Medical School, University of Sydney, and Royal North Shore Hospital, Sydney, Australia
| | - N. Huynh
- Faculté de médicine dentaire, Université de Montréal, Montréal, Canada
| | - P.A. Cistulli
- Charles Perkins Centre and Sydney Medical School, University of Sydney, and Royal North Shore Hospital, Sydney, Australia
| |
Collapse
|
18
|
Chan ASL, Sutherland K, Cistulli PA. Mandibular advancement splints for the treatment of obstructive sleep apnea. Expert Rev Respir Med 2019; 14:81-88. [PMID: 31663416 DOI: 10.1080/17476348.2020.1686978] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Introduction: Obstructive sleep apnea (OSA) is a chronic condition which requires a comprehensive chronic disease management model, rather than a device-focused approach, so as to achieve the best possible health outcomes. Oral appliances are the main alternative to continuous positive airway pressure (CPAP) for the treatment of OSA. There has been an expansion of the research evidence to support the use of oral appliances in clinical practice and the clinical use of oral appliances for the treatment of OSA has become a mainstream practice.Areas covered: This review summarizes the evidence base for the use of oral appliances for the treatment of OSA. The types of oral appliances; their mechanism of action and clinical efficacy for the treatment of OSA; adverse effects, and the impact on patient acceptability and treatment adherence; and clinical effectiveness and health outcomes are discussed.Expert opinion: Personalization of treatment is vitally important in OSA and is a pre-requisite for optimizing adherence with treatment which, in turn, is a key determinant of clinical effectiveness. Treatment of OSA with mandibular advancement splints could provide an equivalent health benefit to CPAP despite not achieving a complete normalization of polysomnographic indices, mediated by differences in adherence profiles.
Collapse
Affiliation(s)
- Andrew S L Chan
- Centre for Sleep Health and Research, Department of Respiratory and Sleep Medicine, Royal North Shore Hospital, St Leonards, Australia.,Northern Clinical School, Faculty of Medicine and Health, The University of Sydney, Australia
| | - Kate Sutherland
- Centre for Sleep Health and Research, Department of Respiratory and Sleep Medicine, Royal North Shore Hospital, St Leonards, Australia.,Northern Clinical School, Faculty of Medicine and Health, The University of Sydney, Australia.,Charles Perkins Centre, Faculty of Medicine and Health, The University of Sydney, Australia
| | - Peter A Cistulli
- Centre for Sleep Health and Research, Department of Respiratory and Sleep Medicine, Royal North Shore Hospital, St Leonards, Australia.,Northern Clinical School, Faculty of Medicine and Health, The University of Sydney, Australia.,Charles Perkins Centre, Faculty of Medicine and Health, The University of Sydney, Australia
| |
Collapse
|
19
|
Marklund M, Braem MJA, Verbraecken J. Update on oral appliance therapy. Eur Respir Rev 2019; 28:190083. [PMID: 31554705 PMCID: PMC9488498 DOI: 10.1183/16000617.0083-2019] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2019] [Accepted: 08/14/2019] [Indexed: 12/26/2022] Open
Abstract
Oral appliances are increasingly recommended for selected patients with obstructive sleep apnoea (OSA) and those who do not tolerate nor prefer continuous positive airway pressure. The most commonly used oral appliance advances the lower jaw during sleep, the so-called mandibular advancement device (MAD). Patients seek treatment because of disturbing snoring, daytime symptoms, apnoeas that disturb sleep and the longer term consequences with regard to cardiovascular risks. MADs reduce the apnoea-hypopnoea index, although to various degrees among patients. Effects on daytime sleepiness have been observed mainly among the more severe OSA patients. Blood pressure may be reduced in MAD-treated OSA patients. There is, however, uncertainty about which patients will respond to this therapy in terms of apnoea reductions, decreased sleepiness and other symptoms, and reduced risk for future impaired health. The occurrence of side-effects also remains difficult to predict at present. The majority of sleep apnoea patients suffer from various comorbidities in terms of cardiovascular diseases, type 2 diabetes and depression. The most recent findings indicate that phenotyping of patients, considering various aspects of this multifaceted disease, will shed more light on the indications for MADs in patients with nightly sleep breathing disturbances. This review summarises the most recent knowledge about MAD treatment.
Collapse
Affiliation(s)
- Marie Marklund
- Dept of Odontology, Medical Faculty, Umeå University, Umeå, Sweden
| | - Marc J A Braem
- Translational Neurosciences, Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium
- Dept of Special Dentistry Care, Antwerp University Hospital, Antwerp, Belgium
| | - Johan Verbraecken
- LEMP, Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium
- Multidisciplinary Sleep Disorders Centre, Antwerp University Hospital, Antwerp, Belgium
| |
Collapse
|
20
|
Metz JE, Attarian HP, Harrison MC, Blank JE, Takacs CM, Smith DL, Gozal D. High-Resolution Pulse Oximetry and Titration of a Mandibular Advancement Device for Obstructive Sleep Apnea. Front Neurol 2019; 10:757. [PMID: 31379712 PMCID: PMC6650535 DOI: 10.3389/fneur.2019.00757] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2019] [Accepted: 07/01/2019] [Indexed: 11/17/2022] Open
Abstract
Background: To determine whether utilizing high-resolution pulse oximetry is a viable method for evaluating the successful titration of oral appliances for the treatment of obstructive sleep apnea (OSA) patients. Methods: Of 136 consecutive potentially eligible OSA patients, 133 were fitted with mandibular advancement devices (MADs), and 101 completed all phases of treatment. The vertical and horizontal dimensions of the appliances were adjusted based on three-nights with a high-resolution pulse oximeter during sleep and associated software after each adjustment. Results: Significant improvements in OSA severity were apparent in patients at all disease severity levels. High-resolution pulse oximetry provided reliable guidance in the titration process of mandibular advancement therapy. In 67 subjects (66.3%), a respiratory event index of <5 events/hour was achieved. Conclusions: OSA can be effectively treated with a MAD at any severity level, and high-resolution pulse oximetry provides critical information to guide oral appliance titration.
Collapse
Affiliation(s)
- James E Metz
- The Metz Center for Sleep Apnea, Columbus, OH, United States
| | - Hrayr P Attarian
- Circadian Rhythms and Sleep Research Lab, Northwestern University Feinberg School of Medicine, Chicago, IL, United States
| | | | - James E Blank
- The Metz Center for Sleep Apnea, Columbus, OH, United States
| | | | - Dale L Smith
- Department of Behavioral Sciences, Olivet Nazarene University, Bourbonnais, IL, United States
| | - David Gozal
- Department of Child Health, University of Missouri School of Medicine, Columbia, MO, United States
| |
Collapse
|
21
|
|
22
|
Donovan TE, Marzola R, Murphy KR, Cagna DR, Eichmiller F, McKee JR, Metz JE, Albouy JP, Troeltzsch M. Annual review of selected scientific literature: A report of the Committee on Scientific Investigation of the American Academy of Restorative Dentistry. J Prosthet Dent 2018; 120:816-878. [DOI: 10.1016/j.prosdent.2018.09.010] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2018] [Accepted: 09/24/2018] [Indexed: 02/08/2023]
|
23
|
Kastoer C, Dieltjens M, Op de Beeck S, Braem MJ, Van de Heyning PH, Vanderveken OM. Remotely Controlled Mandibular Positioning During Drug-Induced Sleep Endoscopy Toward Mandibular Advancement Device Therapy: Feasibility and Protocol. J Clin Sleep Med 2018; 14:1409-1413. [PMID: 30092892 DOI: 10.5664/jcsm.7284] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2017] [Accepted: 02/05/2018] [Indexed: 11/13/2022]
Abstract
STUDY OBJECTIVES The potential of a remotely controlled mandibular positioner (RCMP) during sleep studies in individual patients suffering from obstructive sleep apnea (OSA) for the determination of the effective target protrusive position (ETPP) of the mandible has been demonstrated. The research goal of this study was to assess the feasibility of the application of RCMP during drug-induced sleep endoscopy (DISE) for the determination of ETPP. METHODS Ten patients in whom OSA was diagnosed (50% male; age 54 ± 9.5 years; body mass index 26.9 ± 2.1 kg/m2; apnea-hypopnea index 28.4 ± 13.2 events/h) were enrolled prospectively. Dental RCMP trays were fitted during wakefulness. Maximal protrusion and edge-to-edge positions were measured. Upper airway collapsibility was scored during DISE, including full-range mandibular RCMP titration within 45 minutes. ETPP was defined as the mandibular threshold protrusion yielding a stable upper airway in the absence of snoring, oxygen desaturation and apneas. RESULTS RCMP trays were retentive and no adverse reactions occurred. RCMP was fitted intraorally prior to sedation with maxillary and mandibular trays in edge-to-edge position. Upon sedation, progressive protrusion was performed followed by reversed titration until ETPP was noted. In one patient ETPP was not within the mandibular range of motion. In one patient RCMP needed to be removed because of clenching. CONCLUSIONS The results of this study illustrate that it is feasible to use RCMP during DISE and to determine ETPP within 45 minutes. Comparative research with polysomnography would be useful to further validate the therapy outcome upon use of RCMP during DISE.
Collapse
Affiliation(s)
- Chloé Kastoer
- Department of Otorhinolaryngology, Head and Neck Surgery, Antwerp University Hospital, Antwerp, Belgium.,Translational Neurosciences, Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium
| | - Marijke Dieltjens
- Department of Otorhinolaryngology, Head and Neck Surgery, Antwerp University Hospital, Antwerp, Belgium.,Translational Neurosciences, Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium.,Department of Special Dentistry Care, Antwerp University Hospital, Antwerp, Belgium
| | - Sara Op de Beeck
- Translational Neurosciences, Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium
| | - Marc J Braem
- Translational Neurosciences, Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium.,Department of Special Dentistry Care, Antwerp University Hospital, Antwerp, Belgium
| | - Paul H Van de Heyning
- Department of Otorhinolaryngology, Head and Neck Surgery, Antwerp University Hospital, Antwerp, Belgium.,Translational Neurosciences, Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium.,Multidisciplinary Sleep Disorders Centre, Antwerp University Hospital, Antwerp, Belgium
| | - Olivier M Vanderveken
- Department of Otorhinolaryngology, Head and Neck Surgery, Antwerp University Hospital, Antwerp, Belgium.,Translational Neurosciences, Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium.,Multidisciplinary Sleep Disorders Centre, Antwerp University Hospital, Antwerp, Belgium
| |
Collapse
|