1
|
Semino E, Coltman-Patel T, Dance W, Demjén Z, Hardaker C. Pro-vaccination personal narratives in response to online hesitancy about the HPV vaccine: The challenge of tellability. Discourse Soc 2023; 34:752-771. [PMID: 37842205 PMCID: PMC10572096 DOI: 10.1177/09579265231181075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 10/17/2023]
Abstract
Experimental studies have shown that narratives can be effective persuasive tools in addressing vaccine hesitancy, including regarding the vaccine against the human papillomavirus (HPV), which is transmitted via sexual contact and can cause cervical cancer. This paper presents an analysis of a thread from the online parenting forum Mumsnet Talk where an initially undecided Original Poster is persuaded to vaccinate their child against HPV by a respondent's narrative of cervical cancer that they describe as difficult to share. This paper considers this particular narrative alongside all other narratives that precede the decision announced on the Mumsnet thread. It shows how producing pro-vaccination narratives about HPV involves challenges regarding 'tellability' - what makes the events in a narrative reportable or worth telling. We suggest that this has implications for the context-dependent nature of tellability, the role of parenting forums in vaccination-related discussions, and narrative-based communication about vaccinations more generally.
Collapse
|
2
|
Semino E, Coltman-Patel T, Dance W, Deignan A, Demjén Z, Hardaker C, Mackey A. Narratives, Information and Manifestations of Resistance to Persuasion in Online Discussions of HPV Vaccination. Health Commun 2023:1-12. [PMID: 37733392 DOI: 10.1080/10410236.2023.2257428] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/22/2023]
Abstract
There are both theoretical accounts and empirical evidence for the fact that, in health communication, narratives (story telling) may have a persuasive advantage when compared with information (the provision of facts). The dominant explanation for this potential advantage is that narratives inhibit people's resistance to persuasion, particularly in the form of counterarguing. Evidence in this area to date has most often been gathered through lab or field experiments. In the current study we took a novel approach, gathering our data from naturally-occurring, non-experimental and organically evolving online interactions about vaccinations. We focus on five threads from the parenting forum Mumsnet Talk that centered on indecision about the HPV vaccination. Our analysis revealed that narratives and information were used by posters in similar quantities as a means of providing vaccination-related advice. We also found similar frequencies of direct engagement with both narratives and information. However, our findings showed that narratives resulted in a significantly higher proportion of posts exhibiting supportive engagement, whereas information resulted in posts exhibiting a significantly higher proportion of challenges, including counterarguing and other manifestations of posters' resistance to persuasion. The proportions of supportive versus challenging engagement also varied depending on the topic and vaccine stance of narratives. Notwithstanding contextual explanations for these patterns, our findings, based on this original approach of using naturalistic data, provide a novel kind of evidence for the potential of narratives to inhibit counterarguing in authentic health-related discourse.
Collapse
Affiliation(s)
- Elena Semino
- Department of Linguistics and English Language, Lancaster University
| | | | - William Dance
- Department of Linguistics and English Language, Lancaster University
| | | | - Zsófia Demjén
- UCL Centre for Applied Linguistics, UCL Institute of Education, University College London
| | | | | |
Collapse
|
3
|
Isaac GH, Brockett C, Breckon A, van der Jagt D, Williams S, Hardaker C, Fisher J, Schepers A. Ceramic-on-metal bearings in total hip replacement: whole blood metal ion levels and analysis of retrieved components. ACTA ACUST UNITED AC 2009; 91:1134-41. [PMID: 19721036 DOI: 10.1302/0301-620x.91b9.22306] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
This study reports on ceramic-on-metal (CoM) bearings in total hip replacement. Whole blood metal ion levels were measured. The median increase in chromium and cobalt at 12 months was 0.08 microg/1 and 0.22 microg/1, respectively, in CoM bearings. Comparable values for metal-on-metal (MoM) were 0.48 microg/1 and 0.32 microg/1. The chromium levels were significantly lower in CoM than in MoM bearings (p = 0.02). The cobalt levels were lower, but the difference was not significant. Examination of two explanted ceramic heads revealed areas of thin metal transfer. CoM bearings (one explanted head and acetabular component, one explanted head and new acetabular component, and three new heads and acetabular components) were tested in a hip joint simulator. The explanted head and acetabular component had higher bedding-in. However, after one million cycles all the wear rates were the same and an order of magnitude less than that reported for MoM bearings. There were four outliers in each clinical group, primarily related to component malposition.
Collapse
Affiliation(s)
- G H Isaac
- DePuy International Ltd., Number 1 White Rose Office Park, Leeds LS11 0BG, UK.
| | | | | | | | | | | | | | | |
Collapse
|
4
|
Hardaker C, Dowson D, Isaac GH. Head replacement, head rotation, and surface damage effects on metal-on-metal total hip replacements: A hip simulator study. Proc Inst Mech Eng H 2006; 220:209-17. [PMID: 16669388 DOI: 10.1243/095441105x69097] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
The possibility of replacing the femoral head alone, in either solid or articular surface replacement form, during revision operations on metal-on-metal total hip replacements remains an attractive feature of such implants. In the present investigation, laboratory simulator studies of the influence upon volumetric wear of inserting a new femoral head, of introducing some head rotation, and of damaging the femoral head by scratches have all been explored. New and rotated heads both involve an additional running-in period, but the experimental studies show that the volumetric wear associated with this process is less than the initial running-in wear. The beneficial effects upon volumetric wear of small clearances have been confirmed, while the processing of high-carbon Co-Cr-Mo materials appears to be much less influential. Scratches did not affect wear as much as head replacement or head rotation, but the ongoing wear rates were somewhat higher.
Collapse
|
5
|
Lin ZM, Meakins S, Morlock MM, Parsons P, Hardaker C, Flett M, Isaac G. Deformation of press-fitted metallic resurfacing cups. Part 1: Experimental simulation. Proc Inst Mech Eng H 2006; 220:299-309. [PMID: 16669396 DOI: 10.1243/095441105x69150] [Citation(s) in RCA: 86] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
The interference press fit of a metallic one-piece acetabular cup employed for metal-on-metal hip resurfacing procedures was investigated experimentally under laboratory conditions in the present study, in particular regarding the cup deformation. Tests were carried out in cadavers as well as polyurethane foams of various grades with different elastic moduli to represent different cancellous bone qualities. The cadaver test was used to establish the most suitable configuration of the foam model representing realistic support and geometrical conditions at the pelvis. It was found that a spherical cavity, with two identical areas relieved on opposite sides, was capable of creating a two-point pinching action of the ischeal and ilial columns on the cup as the worst-case scenario. Furthermore, the cup deformation produced from such a two-point loading model with a grade 30 foam was similar to that measured from the cadaver test. Therefore, such a protocol was employed in subsequent experimental tests. For a given size of the outside diameter of the cup of 60 mm, the cup deflection was shown to be dependent largely on the cup wall thickness and the diametral interference between cup and prepared cavity at implantation. For a relatively thin cup with a wall thickness between 2.3 mm (equator) and 4 mm (pole) and with a modest nominal diametral interference of 1 mm, which corresponds to an actual interference of approximately 0.5 mm, the maximum diametral cup deflection (at the rim) was around 60 μm, compared with a diametral clearance of 80-120 μm between the femoral head and the acetabular cup, generally required for fluid-film lubrication and tribological performances. Stiffening of the cup, by both thickening and lateralizing by 1 mm, reduced the cup deformation to between 30 and 50 μm with actual diametral interferences between 0.5 and 1 mm.
Collapse
Affiliation(s)
- Z M Lin
- School of Mechanical Engineering, University of Leeds, Leeds, UK.
| | | | | | | | | | | | | |
Collapse
|
6
|
Fisher J, Hu XQ, Stewart TD, Williams S, Tipper JL, Ingham E, Stone MH, Davies C, Hatto P, Bolton J, Riley M, Hardaker C, Isaac GH, Berry G. Wear of surface engineered metal-on-metal hip prostheses. J Mater Sci Mater Med 2004; 15:225-235. [PMID: 15334994 DOI: 10.1023/b:jmsm.0000015482.24542.76] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
The wear of existing metal-on-metal (MOM) hip prostheses (1 mm3/million cycles) is much lower than the more widely used polyethylene-on-metal bearings (30-100 mm3/million cycles). However, there remain some potential concerns about the toxicity of metal wear particles and elevated metal ion levels, both locally and systemically in the human body. The aim of this study was to investigate the wear, wear debris and ion release of fully coated surface engineered MOM bearings for hip prostheses. Using a physiological anatomical hip joint simulator, five different bearing systems involving three thick (8-12 microm) coatings, TiN, CrN and CrCN, and one thin (2 microm) coating diamond like carbon (DLC) were evaluated and compared to a clinically used MOM cobalt chrome alloy bearing couple. The overall wear rates of the surface engineered prostheses were at least 18-fold lower than the traditional MOM prostheses after 2 million cycles and 36-fold lower after 5 million cycles. Consequently, the volume of wear debris and the ion levels in the lubricants were substantially lower. These parameters were also much lower than in half coated (femoral heads only) systems that have been reported previously. The extremely low volume of wear debris and concentration of metal ions released by these surface engineered systems, especially with CrN and CrCN coatings, have considerable potential for the clinical application of this technology.
Collapse
Affiliation(s)
- J Fisher
- Institute of Medical and Biological Engineering Research Group (iMBE), School of Mechanical Engineering, The University of Leeds, Leeds LS2 9JT, UK.
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
7
|
Fisher J, Hu XQ, Tipper JL, Stewart TD, Williams S, Stone MH, Davies C, Hatto P, Bolton J, Riley M, Hardaker C, Isaac GH, Berry G, Ingham E. An in vitro study of the reduction in wear of metal-on-metal hip prostheses using surface-engineered femoral heads. Proc Inst Mech Eng H 2002; 216:219-30. [PMID: 12206518 DOI: 10.1243/09544110260138709] [Citation(s) in RCA: 66] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Although the wear of existing metal-on-metal (MOM) hip prostheses (1 mm3/10(6) cycles) is much lower than the more widely used polyethylene-on-metal bearings, there are concerns about the toxicity of metal wear particles and elevated metal ion levels, both locally and systemically, in the human body. The aim of this study was to investigate the possibility of reducing the volume of wear, the concentration of metal debris and the level of metal ion release through using surface-engineered femoral heads. Three thick (8-12 microm) coatings (TiN, CrN and CrCN) and one thin (2 microm) coating (diamond-like carbon, DLC), were evaluated on the femoral heads when articulating against high carbon content cobalt-chromium alloy acetabular inserts (HC CoCrMo) and compared with a clinically used MOM cobalt-chromium alloy bearing couple using a physiological anatomical hip joint simulator (Leeds Mark II). This study showed that CrN, CrCN and DLC coatings produced substantially lower wear volumes for both the coated femoral heads and the HC CoCrMo inserts. The TiN coating itself had little wear, but it caused relatively high wear of the HC CoCrMo inserts compared with the other coatings. The majority of the wear debris for all half-coated couples comprised small, 30 nm or less, CoCrMo metal particles. The Co, Cr and Mo ion concentrations released from the bearing couples of CrN-, CrCN- and DLC-coated heads articulating against HC CoCrMo inserts were at least 7 times lower than those released from the clinical MOM prostheses. These surface-engineered femoral heads articulating on HC CoCrMo acetabular inserts produced significantly lower wear volumes and rates, and hence lower volumetric concentrations of wear particles, compared with the clinical MOM prosthesis. The substantially lower ion concentration released by these surface-engineered components provides important evidence to support the clinical application of this technology.
Collapse
Affiliation(s)
- J Fisher
- Medical and Biological Engineering Research Group, School of Mechanical Engineering, University of Leeds, UK
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
8
|
Sakoda H, Voice AM, McEwen HM, Isaac GH, Hardaker C, Wroblewski BM, Fisher J. A comparison of the wear and physical properties of silane cross-linked polyethylene and ultra-high molecular weight polyethylene. J Arthroplasty 2001; 16:1018-23. [PMID: 11740757 DOI: 10.1054/arth.2001.27234] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
Cross-linked polyethylenes are being introduced widely in acetabular cups in hip prostheses as a strategy to reduce the incidence of wear debris-induced osteolysis. It will be many years before substantial clinical data can be collected on the wear of these new materials. Silane cross-linked polyethylene (XLPE) was introduced into clinical practice in a limited series of acetabular cups in 1986 articulating against 22.225-mm alumina ceramic femoral heads and showed reduced wear rates compared with conventionally sterilized (gamma irradiation in air) ultra-high molecular weight polyethylene (UHMWPE). We compared the wear of XLPE manufactured in 1986 with the wear of UHMWPE manufactured in 1986 in nonirradiated and irradiated forms. In the nonirradiated forms, the wear of XLPE was 3 times less than UHWMPE when articulating against smooth counterfaces. The nonirradiated materials did not show signs of oxidation. In the irradiated forms, only UHMWPE showed high levels of oxidation, and this caused a substantial increase in wear. Antioxidants added to XLPE during processing gave resistance to oxidative degradation. When sliding against scratched counterfaces, the wear of UHMWPE increased by a factor of 2 to 3 times. Against the same scratched counterfaces, the wear of XLPE increased dramatically by 30 to 200 times. This difference may be attributed to the reduction in toughness of XLPE. Clinically, XLPE has been articulated against damage-resistant ceramic heads, and this probably has been an important factor in contributing to reduced wear. New cross-linked polyethylenes differ considerably from XLPE. This study indicates that it is prudent to examine the wear of new polyethylenes under a range of conditions that may occur in vivo.
Collapse
Affiliation(s)
- H Sakoda
- Department of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, United Kingdom
| | | | | | | | | | | | | |
Collapse
|
9
|
McEwen HM, Fisher J, Goldsmith AA, Auger DD, Hardaker C, Stone MH. Wear of fixed bearing and rotating platform mobile bearing knees subjected to high levels of internal and external tibial rotation. J Mater Sci Mater Med 2001; 12:1049-1052. [PMID: 15348363 DOI: 10.1023/a:1012850224565] [Citation(s) in RCA: 60] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
In order to extend the lifetime of total knee replacements (TKR) in vivo, reduction of the volumetric wear rate of ultra high molecular weight polyethylene (UHMWPE) bearings remains an important goal. The volume of wear debris generated in fixed bearing total knee devices increases significantly when subjected to higher levels of internal-external rotation and anterior-posterior displacement. Six PFC Sigma fixed bearing TKR were compared with six LCS rotating platform mobile bearing knees using a physiological knee simulator with high rotation kinematic inputs. The rotating platform polyethylene inserts exhibited a mean wear rate which was one-third of that of the fixed bearing inserts despite having increased femoral contact areas and additional tibial wear surfaces. The rotating platform design decouples knee motions, by allowing unidirectional motion at the tray-insert articulation, which reduces rotation at the femoral-insert counterface. This translation of complex knee motions into more unidirectional motions results in molecular orientation of the UHMWPE and reduced volumetric wear.
Collapse
Affiliation(s)
- H M McEwen
- School of Mechanical Engineering, University of Leeds, Leeds LS2 9JT, UK
| | | | | | | | | | | |
Collapse
|
10
|
Jones VC, Barton DC, Auger DD, Hardaker C, Stone MH, Fisher J. Simulation of tibial counterface wear in mobile bearing knees with uncoated and ADLC coated surfaces. Biomed Mater Eng 2001; 11:105-15. [PMID: 11352110] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/16/2023]
Abstract
A multidirectional pin-on-plate reciprocating machine was used to compare the wear performance of UHMWPE sliding against cast cobalt chrome (CoCr) plates that were either untreated or coated with Amorphous Diamond Like Carbon (ADLC). The test conditions were based on a 1/5 scale model representative of in vivo motion at the tibial counterfaces of unconstrained mobile bearing knees. The average +/- STERR wear rates were 13.78+/-1.06 mm3/Mcycles for the ADLC counterfaces and 0.504+/-0.12 mm3/Mcycles for the control CoCr counterfaces. All of the pins run on the ADLC counterfaces exhibited the same patterns of blistering along the central axis, and severe abrasion elsewhere to the extent that all of the original machining marks were removed after just one week of testing. The average value of friction coefficient was 0.24 for the ADLC counterfaces and 0.073 for the control CoCr counterfaces. The factor of 3.5 increase was statistically significant at p < 0.05. In the tribological evaluation of ADLC coatings for tibial trays in mobile bearing knees, this study shows that this specific Physical Vapour Deposition (PVD) ADLC showed significantly poorer frictional and wear performance than uncoated surfaces which was sufficient to negate any potential benefits of improved resistance to third body damage.
Collapse
Affiliation(s)
- V C Jones
- Medical and Biological Engineering Group, School of Mechanical Engineering, University of Leeds, UK
| | | | | | | | | | | |
Collapse
|
11
|
Abstract
Twenty-eight standard Charnley sockets were retrieved at revision surgery. The penetration angle with respect to the cup coordinate system, beta, and penetration depth, d, of the sockets were measured using both the traditional shadowgraph technique and by analysing data obtained from a coordinate measuring machine (CMM). In addition, d was deduced radiographically from pre-revision X-rays. Limits of agreement between the three methods of measuring d were of the order of +/- 0.5 mm. Using the data obtained from the CMM it was possible to deduce the wear volume Vmeas directly. It was found that, in general, values of the wear volume calculated from d and beta using equations cited elsewhere (1, 2) were both imprecise and inaccurate. The direct measurement of the wear volume using the CMM depends on the location of reference points external to the wear surface. If such surfaces were damaged, then it was concluded that the shadowgraph technique provided the most suitable method for measuring the dimensional changes in the retrieved socket, due to its relative ease of use.
Collapse
Affiliation(s)
- R M Hall
- Centre for Biomedical Engineering, University of Durham
| | | | | | | | | | | |
Collapse
|
12
|
Derbyshire B, Fisher J, Dowson D, Hardaker C, Brummitt K. Comparative study of the wear of UHMWPE with zirconia ceramic and stainless steel femoral heads in artificial hip joints. Med Eng Phys 1994; 16:229-36. [PMID: 8061909 DOI: 10.1016/1350-4533(94)90042-6] [Citation(s) in RCA: 119] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
The wear of ultra high molecular weight polyethylene (UHMWPE) when sliding against zirconia ceramic and stainless steel counterfaces has been compared in a pin-on-plate reciprocator and in a hip joint simulator. A lower wear factor was found for the UHMWPE when sliding on the zirconia ceramic counterfaces in the pin-on-plate tests. In the hip joint simulator test, the acetabular cups articulating on zirconia heads showed consistently lower volume changes than the cups articulating on stainless steel heads. The higher volume changes found with the stainless steel heads were associated with an increased roughness of the femoral heads during the tests. This roughening was caused by the adherence of a rough polymer transfer film.
Collapse
Affiliation(s)
- B Derbyshire
- Department of Mechanical Engineering, University of Leeds, UK
| | | | | | | | | |
Collapse
|
13
|
Hall R, Unsworth A, Wroblewski B, Hardaker C. Tribological characterisation of explanted charnley hip prostheses. J Biomech 1994. [DOI: 10.1016/0021-9290(94)91416-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|