Marshall NW, Vandenbroucke D, Cockmartin L, Wanninger F, Smet M, Feng Y, Ni Y, Bosmans H. Seven general radiography x-ray detectors with pixel sizes ranging from 175 to 76 μm: technical evaluation with the focus on orthopaedic imaging. Phys Med Biol 2023; 68:195007. [PMID: 37659394 DOI: 10.1088/1361-6560/acf642] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2023] [Accepted: 09/01/2023] [Indexed: 09/04/2023]
Abstract
Aim. Flat panel detectors with small pixel sizes general can potentially improve imaging performance in radiography applications requiring fine detail resolution. This study evaluated the imaging performance of seven detectors, covering a wide range of pixel sizes, in the frame of orthopaedic applications.Material and methods. Pixel sizes ranged from 175 (detector A175) to 76μm (detector G76). Modulation transfer function (MTF) and detective quantum efficiency (DQE) were measured using International Electrotechnical Commission (IEC) RQA3 beam quality. Threshold contrast (CT) and a detectability index (d') were measured at three air kerma/image levels. Rabbit shoulder images acquired at 60 kV, over five air kerma levels, were evaluated in a visual grading study for anatomical sharpness, image noise and overall diagnostic image quality by four radiologists. The detectors were compared to detector E124.Results. The 10% point of the MTF ranged from 3.21 to 4.80 mm-1, in going from detector A175to detector G76. DQE(0.5 mm-1) measured at 2.38μGy/image was 0.50 ± 0.05 for six detectors, but was higher for F100at 0.62. High frequency DQE was superior for the smaller pixel detectors, howeverCTfor 0.25 mm discs correlated best with DQE(0.5 mm-1). Correlation betweenCTand the detectability model was good (R2= 0.964).CTfor 0.25 mm diameter discs was significantly higher for D150and F100compared to E124. The visual grading data revealed higher image quality ratings for detectors D125and F100compared to E124. An increase in air kerma was associated with improved perceived sharpness and overall quality score, independent of detector. Detectors B150, D125, F100and G76, performed well in specific tests, however only F100consistently outperformed the reference detector.Conclusion. Pixel size alone was not a reliable predictor of small detail detectability or even perceived sharpness in a visual grading analysis study.
Collapse
Affiliation(s)
- N W Marshall
- UZ Gasthuisberg, Department of Radiology, Herestraat 49, B-3000 Leuven, Belgium
- Medical Imaging Research Center, Medical Physics and Quality Assessment, Katholieke Universiteit Leuven, B-3000 Leuven, Belgium
- Agfa N.V., Septestraat 27, B-2640 Mortsel, Belgium
| | | | - L Cockmartin
- UZ Gasthuisberg, Department of Radiology, Herestraat 49, B-3000 Leuven, Belgium
| | - F Wanninger
- Agfa-Gevaert HealthCare GmbH, München, Germany
| | - M Smet
- UZ Gasthuisberg, Department of Radiology, Herestraat 49, B-3000 Leuven, Belgium
| | - Y Feng
- Theragnostic Laboratory, Biomedical Group, Katholieke Universiteit Leuven, B-3000 Leuven, Belgium
| | - Y Ni
- Theragnostic Laboratory, Biomedical Group, Katholieke Universiteit Leuven, B-3000 Leuven, Belgium
| | - H Bosmans
- UZ Gasthuisberg, Department of Radiology, Herestraat 49, B-3000 Leuven, Belgium
- Medical Imaging Research Center, Medical Physics and Quality Assessment, Katholieke Universiteit Leuven, B-3000 Leuven, Belgium
| |
Collapse
|
2
|
Notohamiprodjo S, Roeper KM, Treitl KM, Hoberg B, Wanninger F, Verstreepen L, Mueck FG, Maxien D, Fischer F, Peschel O, Wirth S. Image quality is resilient against tube voltage variations in post-mortem skeletal radiography with a digital flat-panel detector. Sci Rep 2021; 11:7701. [PMID: 33833315 PMCID: PMC8032833 DOI: 10.1038/s41598-021-87294-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2020] [Accepted: 03/24/2021] [Indexed: 11/09/2022] Open
Abstract
In recent phantom studies low-contrast detectability was shown to be independent from variations in tube voltage in digital radiography (DR) systems. To investigate the transferability to a clinical setting, the lower extremities of human cadavers were exposed at constant detector doses with different tube voltages in a certain range, as proposed in the phantom studies. Three radiologists independently graded different aspects of image quality (IQ) in a comparative analysis. The grades show no correlation between IQ and kV, which means that the readers were not able to recognize a significant IQ difference at different kV. Signal-to-noise and contrast-to-noise ratios showed no significant differences in IQ despite the kV-setting variations. These findings were observed from a limited kV range setting. Higher kV-settings resulted in lowest patient exposure at constant IQ. These results confirm the potential of DR-systems to contribute to standardization of examination protocols comparable to computed tomography. This may prevent the trend to overexpose. Further investigations in other body regions and other DR-systems are encouraged to determine transferability.
Collapse
Affiliation(s)
- S Notohamiprodjo
- Department of Nuclear Medicine, Klinikum Rechts Der Isar, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany.
| | - K M Roeper
- Department of Ophtalmology, Klinikum Rechts Der Isar, Technical University of Munich, Munich, Germany
| | - K M Treitl
- Department of Radiology, University Hospital of Munich, LMU Munich, Munich, Germany
| | - B Hoberg
- Agfa HealthCare Germany GmbH, Bonn, Germany
| | - F Wanninger
- Agfa-Gevaert HealthCare GmbH, Munich, Germany
| | | | - F G Mueck
- Department of Radiology, HELIOS Klinikum München West, Munich, Germany
| | - D Maxien
- Radiologie Zentrum München, Munich, Germany
| | - F Fischer
- Institute of Forensic Medicine, LMU Munich, Munich, Germany
| | - O Peschel
- Institute of Forensic Medicine, LMU Munich, Munich, Germany
| | - S Wirth
- Institute of Radiology, Schwarzwald-Baar Klinikum, Villingen-Schwenningen, Germany
| |
Collapse
|
3
|
Notohamiprodjo S, Verstreepen L, Wanninger F, Hoberg B, Röper KM, Mück FG, Treitl KM, Maxien D, Wirth S. Dependence of low contrast detail on exposure dose and tube voltage in digital flat-panel detector radiography—a pre-clinical phantom study. Biomed Phys Eng Express 2018. [DOI: 10.1088/2057-1976/aa9b8a] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
4
|
Grahn A, Hemdal B, Andersson I, Ruschin M, Thilander-Klang A, Börjesson S, Tingberg A, Mattsson S, Håkansson M, Båth M, Månsson LG, Medin J, Wanninger F, Panzer W. Clinical evaluation of a new set of image quality criteria for mammography. Radiat Prot Dosimetry 2005; 114:389-94. [PMID: 15933143 DOI: 10.1093/rpd/nch573] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
The European Commission (EC) quality criteria for screen-film mammography are used as a tool to assess image quality. A new set of criteria was developed and initially tested in a previous study. In the present study, these criteria are further evaluated using screen-film mammograms that have been digitised, manipulated to simulate different image quality levels and reprinted on film. Expert radiologists have evaluated these manipulated images using both the original (EC) and the new criteria. A comparison of three different simulated dose levels reveals that the new criteria yield a larger separation of image criteria scores than the old ones. These results indicate that the new set of image quality criteria has a higher discriminative power than the old set and thus seems to be more suitable for evaluation of image quality in mammography.
Collapse
Affiliation(s)
- A Grahn
- Department of Medical Radiation Physics, Lund University, Malmö University Hospital, 205 02 Malmö, Sweden.
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
5
|
Treiber O, Wanninger F, Führ H, Panzer W, Regulla D, Winkler G. An adaptive algorithm for the detection of microcalcifications in simulated low-dose mammography. Phys Med Biol 2003; 48:449-66. [PMID: 12630741 DOI: 10.1088/0031-9155/48/4/303] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
This paper uses the task of microcalcification detection as a benchmark problem to assess the potential for dose reduction in x-ray mammography. We present the results of a newly developed algorithm for detection of microcalcifications as a case study for a typical commercial film-screen system (Kodak Min-R 2000/2190). The first part of the paper deals with the simulation of dose reduction for film-screen mammography based on a physical model of the imaging process. Use of a more sensitive film-screen system is expected to result in additional smoothing of the image. We introduce two different models of that behaviour, called moderate and strong smoothing. We then present an adaptive, model-based microcalcification detection algorithm. Comparing detection results with ground-truth images obtained under the supervision of an expert radiologist allows us to establish the soundness of the detection algorithm. We measure the performance on the dose-reduced images in order to assess the loss of information due to dose reduction. It turns out that the smoothing behaviour has a strong influence on detection rates. For moderate smoothing. a dose reduction by 25% has no serious influence on the detection results. whereas a dose reduction by 50% already entails a marked deterioration of the performance. Strong smoothing generally leads to an unacceptable loss of image quality. The test results emphasize the impact of the more sensitive film-screen system and its characteristics on the problem of assessing the potential for dose reduction in film-screen mammography. The general approach presented in the paper can be adapted to fully digital mammography.
Collapse
Affiliation(s)
- O Treiber
- Institute of Biomathematics and Biometry, GSF-National Research Center for Environment and Health, Ingolstädter Landstrasse 1, 85764 Neuherberg, Germany
| | | | | | | | | | | |
Collapse
|
6
|
Magin TM, Schröder R, Leitgeb S, Wanninger F, Zatloukal K, Grund C, Melton DW. Lessons from keratin 18 knockout mice: formation of novel keratin filaments, secondary loss of keratin 7 and accumulation of liver-specific keratin 8-positive aggregates. J Cell Biol 1998; 140:1441-51. [PMID: 9508776 PMCID: PMC2132680 DOI: 10.1083/jcb.140.6.1441] [Citation(s) in RCA: 175] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/1997] [Revised: 01/15/1998] [Indexed: 02/06/2023] Open
Abstract
Here, we report on the analysis of keratin 18 null mice. Unlike the ablation of K8, which together with K18 is expressed in embryonic and simple adult epithelia, K18 null mice are viable, fertile, and show a normal lifespan. In young K18 null mice, hepatocytes were completely devoid of keratin filaments. Nevertheless, typical desmosomes were formed and maintained. Old K18 null mice, however, developed a distinctive liver pathology with abnormal hepatocytes containing K8-positive aggregates. These stained positively for ubiquitin and MM120-1 and were identified as Mallory bodies, one hallmark of human alcoholic hepatitis. This is the first demonstration that the ablation of one keratin leads to the accumulation of its single partner. Another striking finding was the absence or drastic down regulation of K7 in several tissues despite its ongoing transcription. Moreover, K18 null mice revealed new insights in the filament-forming capacity of the tail-less K19 in vivo. Due to the unexpected secondary loss of K7, only K8/19 are expressed in the uterine epithelium of K18 null mice. Immunoelectron microscopy of this tissue demonstrated the presence of typical K8/19 IF, thus highlighting in vivo that K19 is a fully competent partner for K8.
Collapse
Affiliation(s)
- T M Magin
- Institut fuer Genetik, Abteilung Molekulargenetik, Universitat Bonn, Bonn, Germany.
| | | | | | | | | | | | | |
Collapse
|