1
|
TAV-in-TAV in patients with prosthesis embolization: Impact of commissural alignment and global outcomes. Int J Cardiol 2024:132179. [PMID: 38761972 DOI: 10.1016/j.ijcard.2024.132179] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/30/2024] [Revised: 05/02/2024] [Accepted: 05/13/2024] [Indexed: 05/20/2024]
Abstract
BACKGROUND Optimal strategies to manage embolization of transcatheter aortic valve implantation (TAVI) devices are unclear; valve-in-valve (ViV) is often used. We aimed to describe through one-single center experience its rate, causes, consequences, and management as well as the rate and relevance of commissural alignment (CA) in this context. METHODS We identified across 1038 TAVI cases, those cases requiring ViV for the management of first device embolization. CA (absence or mild misalignment) after first and second device was assessed by CT or fluoroscopy. RESULTS A total of 23 cases (2.2%) were identified, 52.3% embolized towards the aorta and 47.7% towards the ventricle. Suboptimal implant height (38%) and embolization at the time of post-dilation (23%) were the most frequent mechanisms together with greater rate of bicuspid valve (p < 0.001) and a trend to greater annular eccentricity. Procedural and 1-year death occurred in 13% and 34%, respectively (vs. 1.1% and 7.8% in the global cohort, p < 0.001). CA was present in 76.9% of the prostheses initially implanted but was only spontaneously achieved in 30.8% of the second ViV device. Adequate CA of both prostheses was identified in only two cases (8.7%). There were no cases of coronary obstruction. CONCLUSIONS TAVI device embolization mechanisms can often be predicted and prevented. Mortality following bail-out ViV is higher than in regular TAVI procedures but 2/3 of these patients survived beyond 1-year follow-up. In them, valve degeneration or coronary re-access might be particularly challenging since CA was rarely achieved with both devices suggesting that greater efforts should be made in this regard.
Collapse
|
2
|
Response by Amat-Santos et al to Letter Regarding Article, "Laser Coronary Atherectomy and Polymeric Coronary Wires in Uncrossable Lesions: a Word of Caution". Circ Cardiovasc Interv 2024; 17:e013996. [PMID: 38502724 DOI: 10.1161/circinterventions.124.013996] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/21/2024]
|
3
|
Laser Coronary Atherectomy and Polymeric Coronary Wires in Uncrossable Lesions: A Word of Caution. Circ Cardiovasc Interv 2024; 17:e013427. [PMID: 38227700 DOI: 10.1161/circinterventions.123.013427] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/18/2024]
|
4
|
Cardiac amyloidosis and left atrial appendage closure. The CAMYLAAC Study. REVISTA ESPANOLA DE CARDIOLOGIA (ENGLISH ED.) 2022:S1885-5857(22)00208-0. [PMID: 35934294 DOI: 10.1016/j.rec.2022.08.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/13/2022] [Accepted: 07/27/2022] [Indexed: 06/15/2023]
Abstract
INTRODUCTION AND OBJECTIVES Transthyretin cardiac amyloidosis (ATTR-CA) patients often have atrial fibrillation and increased bleeding/thrombogenic risks. We aimed to evaluate outcomes of left atrial appendage closure (LAAC) compared with patients without a known diagnosis of CA. METHODS Comparison at long-term of patients diagnosed with ATTR-CA who underwent LAAC between 2009 and 2020 and those without a known diagnosis of CA. RESULTS We studied a total of 1159 patients. Forty patients (3.5%) were diagnosed with ATTR-CA; these patients were older and had more comorbidities, higher HAS-BLED and CHA2DS2-VASc scores, and lower left ventricular function. Successful LAAC was achieved in 1137 patients (98.1%) with no differences between groups. Regarding in-hospital and follow-up complications, there were no differences between the groups in ischemic stroke (5% vs 2.5% in those without a known diagnosis of CA; P=.283), hemorrhagic stroke (2.5% and 0.8% in the control group; P=.284), major or minor bleeding. At the 2-year follow-up, there were no significant differences in mortality (ATTR-CA: 20% vs those without known CA: 13.6%, 0.248); however, the at 5-year follow-up, ATTR-CA patients had higher mortality (40% vs 19.2%; P <.001) but this difference was unrelated to hemorrhagic complications or ischemic stroke. CONCLUSIONS LAAC could reduce the risk of bleeding complications and ischemic cerebrovascular events without increasing the rate of early or mid-term complications. Although long-term survival was impaired in ATTR-CA patients, it was comparable to that of patients without a known diagnosis of CA at the 2-year follow-up, suggesting that LAAC for patients with ATTR-CA might not be futile.
Collapse
|
5
|
Impact of operatoŕs experience on peri-procedural outcomes with Watchman FLX: Insights from the FLX-SPA registry. IJC HEART & VASCULATURE 2022; 38:100941. [PMID: 35024431 PMCID: PMC8728396 DOI: 10.1016/j.ijcha.2021.100941] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 12/09/2021] [Accepted: 12/23/2021] [Indexed: 12/31/2022]
Abstract
BACKGROUND The Watchman FLX is a device upgrade of the Watchman 2.5 that incorporates several design enhancements intended to simplify left atrial appendage occlusion (LAAO) and improve procedural outcomes. This study compares peri-procedural results of LAAO with Watchman FLX (Boston Scientific, Marlborough, Massachusetts) in centers with varying degrees of experience with the Watchman 2.5 and Watchman FLX. METHODS Prospective, multicenter, "real-world" registry including consecutive patients undergoing LAAO with the Watchman FLX at 26 Spanish sites (FLX-SPA registry). Implanting centers were classified according to the center's prior experience with the Watchman 2.5. A further division of centers according to whether or not they had performed ≤ 10 or > 10Watchman FLX implants was prespecified at the beginning of the study. Procedural outcomes of institutions stratified according to their experience with the Watchman 2.5 and FLX devices were compared. RESULTS 359 patients [mean age 75.5 (SD8.1), CHA2DS2-VASc 4.4 (SD1.4), HAS-BLED 3.8(SD0.9)] were included. Global success rate was 98.6%, successful LAAO with the first selected device size was achieved in 95.5% patients and the device was implanted at first attempt in 78.6% cases. There were only 9(2.5%) major peri-procedural complications. No differences in efficacy or safety results according to the centeŕs previous experience with Watchman 2.5 and procedural volume with Watchman FLX existed. CONCLUSIONS The Watchman FLX attains high procedural success rates with complete LAA sealing in unselected, real-world patients, along with a low incidence of peri-procedural complications, regardless of operatoŕs experience with its previous device iteration or the number of Watchman FLX devices implanted.
Collapse
|
6
|
Commissural Versus Coronary Optimized Alignment During Transcatheter Aortic Valve Replacement. JACC Cardiovasc Interv 2022; 15:135-146. [PMID: 35057983 DOI: 10.1016/j.jcin.2021.10.005] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Revised: 09/14/2021] [Accepted: 10/05/2021] [Indexed: 10/19/2022]
Abstract
OBJECTIVES The aims of this study were to determine the rate of noncentered coronary ostia and their risk for coronary overlap (CO) and to develop an improved orientation strategy for transcatheter aortic valve replacement (TAVR) devices taking into account anatomical cues to identify patients at risk for CO regardless of commissural alignment and compute an alternative, CO-free TAVR rotation angle for those patients. BACKGROUND Commissural alignment during TAVR reduces CO risk. However, eccentricity of coronary ostia from the center of the sinus of Valsalva may result in CO even after perfect alignment of TAVR commissures. METHODS Baseline computed tomography from TAVR candidates helped identify distance from commissures to the right coronary artery (RCA) and the left coronary artery (LCA). Then, for each case, a virtual valve was simulated with ideal commissural or coronary alignment, and the degree of CO was determined. On the basis of the potential BASILICA (bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction) efficacy, 3 groups were defined: no risk for CO (>35° from neocommissure to coronary ostia), moderate risk (20°-35°), and severe risk (≤20°). RESULTS Computed tomographic studies from 107 patients were included. After excluding 7 patients (poor quality or bicuspid valve), 100 patients were analyzed. The RCA showed greater eccentricity compared with the LCA (18.5° [IQR: 3.3°-12.8°] vs 6.5° [IQR: 3.3°-12.8°]; P < 0.001). The mean intercoronary angle was 140.0° ± 18.7° (95% CI: 136.3°-143.7°). Thirty-two patients had moderate to severe risk for CO (≤35°) despite ideal commissural alignment. Greater coronary eccentricity (cutoff for RCA, 24.5°; cutoff for LCA, 19°) and intercoronary angle >147.5° or <103° were associated with greater risk for moderate to severe CO despite commissural alignment (area under the curve: 0.97; 95% CI: 0.91-0.99). If optimal coronary alignment was simulated, this prevented severe CO in all cases and reduced moderate CO from 27% to 5% (P < 0.001). CONCLUSIONS One third of patients would have CO during TAVR-in-TAVR despite commissural alignment; a 6-fold decrease in this risk was achieved with optimized coronary alignment. Coronary eccentricity and intercoronary angle were the main predictors.
Collapse
|
7
|
Myval versus alternative balloon- and self-expandable transcatheter heart valves: A central core lab analysis of conduction disturbances. Int J Cardiol 2022; 351:25-31. [PMID: 34979152 DOI: 10.1016/j.ijcard.2021.12.049] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Revised: 12/27/2021] [Accepted: 12/28/2021] [Indexed: 12/29/2022]
Abstract
BACKGROUND Several studies have compared surface electrocardiographic changes following different self-expandable (SE) (Evolut (Medtronic, USA); Acurate (Boston Scientific, USA); Portico (Abbott, USA); and Allegra (NVT, Germany)) and balloon-expandable (BE) Sapien-3 (Edwards Lifesciences, USA) transcatheter heart valves. We aimed to compare these prosthesis with the novel Myval BE prosthesis (Meril Life, India). METHODS Academic European registry of consecutive patients with severe aortic stenosis who received any of the 6 aforementioned valves. Baseline, post-procedural, and discharge 12‑leads electrocardiograms (ECG) were centrally analyzed and compared. RESULTS A total of 1131 patients were included: 135 Myval (11.9%), 290 Sapien-3 (25.6%), 298 Evolut (26.3%), 180 Acurate (15.9%), 125 Portico (11.1%), and 103 Allegra (9.1%). There were no baseline differences in intraventricular conduction disturbances rate. Compared to the novel BE Myval, there were similar procedural and in-hospital outcomes. Similar rates of early new permanent pacemaker implant (PPI) were observed amongst Myval (7.4%), Sapien-3 (13.4%), and Acurate (9.1%), but Evolut, Portico, and Allegra presented significantly higher rates (18.5%, p = 0.003; 29.5% p < 0.001 and 22%, p = 0.001, respectively). Central analysis of ECGs, unraveled significant prolongation of the PR segment with Evolut, Portico and Allegra whereas Evolut, Acurate, and Portico showed significant QRS widening compared to Myval. However, at discharge no differences in PR segment duration were observed while, Evolut, and Portico- but not Acurate, Allegra or Sapien-3 - still presented significant widening of QRS segment compared to Myval. CONCLUSIONS After blinded central ECG analysis, the novel Myval balloon-expandable prosthesis was associated with a low rate of early conduction disturbances.
Collapse
|
8
|
Self-expandable transcatheter heart valves for aortic stenosis. Short-term outcome and matched hemodynamic performance. REVISTA ESPANOLA DE CARDIOLOGIA (ENGLISH ED.) 2021; 74:1032-1041. [PMID: 33158760 DOI: 10.1016/j.rec.2020.09.014] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Accepted: 09/15/2020] [Indexed: 06/11/2023]
Abstract
INTRODUCTION AND OBJECTIVES Aortic self-expandable (SE) transcatheter aortic valve implantation (TAVI) devices are particularly useful for patients with aortic stenosis and small/tortuous vessels, small aortic annuli, or low coronary ostia. However, it is unclear whether the growing range of SE devices shows comparable hemodynamic and clinical outcomes. We aimed to determine the differential hemodynamic (residual valve area and regurgitation) and clinical outcomes of these devices in comparable scenarios. METHODS All patients were enrolled from 4 institutions and were managed with 4 different SE TAVI devices. Baseline and follow-up clinical data were collected and echocardiographic tests blindly and centrally analyzed. Patients were compared according to valve type and a 1:1 matched comparison was performed according to degree of calcification, aortic annulus dimensions, left ventricular ejection fraction, and body surface area. RESULTS In total, 514 patients were included (Evolut R/PRO, 217; ACURATE neo, 107; ALLEGRA, 102; Portico, 88). Surgical risk scores were comparable in the unmatched population. No differences were observed in the post-TAVI regurgitation rate and in in-hospital mortality (2.7%). The rate of pacemaker implantation at discharge was significantly different among devices (P=.049), with Portico showing the highest rate (23%) and ACURATE neo the lowest (9.5%); Evolut R/PRO and ALLEGRA had rates of 15.9% and 21.2%, respectively. The adjusted comparison showed worse residual TAVI gradients and aortic valve area with ACURATE neo vs ALLEGRA (P=.001) but the latter had higher risk of valve embolization and a tendency for more cerebrovascular events. CONCLUSIONS A matched comparison of 4 SE TAVI devices showed no differences regarding residual aortic regurgitation and in-hospital mortality.
Collapse
|
9
|
Prótesis percutáneas autoexpandibles para la estenosis aórtica: resultados a corto plazo y comparación hemodinámica tras emparejamiento. Rev Esp Cardiol 2021. [DOI: 10.1016/j.recesp.2020.09.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
10
|
Resultados del TAVI emergente comparado con el procedimiento electivo: metan�lisis. REC: INTERVENTIONAL CARDIOLOGY 2021. [DOI: 10.24875/recic.m21000200] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
|
11
|
Accurate commissural alignment during ACURATE neo TAVI procedure. Proof of concept. REVISTA ESPANOLA DE CARDIOLOGIA (ENGLISH ED.) 2021; 75:203-212. [PMID: 33781722 DOI: 10.1016/j.rec.2021.02.004] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/10/2020] [Accepted: 02/12/2021] [Indexed: 10/21/2022]
Abstract
INTRODUCTION AND OBJECTIVES Final position of the neo-commissures is uncontrolled during transcatheter aortic valve implantation (TAVI), potentially hindering coronary access and future procedures. We aimed to develop a standard method to achieve commissural alignment with the ACURATE neo valve. METHODS The relationship between native and TAVI neo-commissures was analyzed in 11 severe aortic stenosis patients undergoing TAVI. Based on computed tomography analysis, an in silico model was developed to predict final TAVI commissural posts position. A modified implantation technique, accurate commissural alignment (ACA) and a dedicated delivery system were developed. TAVI implants were tested in 3-dimensional (3D) printed models and in vivo. Commissural misalignment and coronary overlap (CO) were analyzed. RESULTS The in silico model accurately predicted final position of commissural posts irrespective of the implantation technique performed (correlation coefficient, 0.994; 95%CI, 0.989-0.998; P<.001). TAVI implant with patient-specific rotation was simulated in 3D printed models and in 9 patients. ACA-oriented TAVI implants presented adequate commissural alignment in vivo (mean commissural misalignment of 7.7 ±3.9°). None of the ACA oriented implants showed CO, whereas in silico conventional implants predicted CO in 6 of the 9 cases. CONCLUSIONS Accurate commissural alignment of the ACURATE neo device is feasible by inserting the delivery system with a patient-specific rotation based on computed tomography analysis. This is a simple and reproducible method for commissural alignment that can be potentially used for all kinds of TAVI devices.
Collapse
|
12
|
Transaxillary transcatheter ACURATE neo aortic valve implantation - The TRANSAX multicenter study. Catheter Cardiovasc Interv 2020; 98:E291-E298. [PMID: 33315296 DOI: 10.1002/ccd.29423] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/22/2020] [Revised: 10/25/2020] [Accepted: 11/29/2020] [Indexed: 11/09/2022]
Abstract
BACKGROUND Transcatheter aortic valve replacement (TAVR) via transaxillary (TAx) approach with ACURATE neo valve is an off-label procedure. Our aim was to gather information on ACURATE neo cases implanted via TAx approach and report major outcomes. METHODS AND RESULTS The TRANSAX Study (NCT04274751) retrospectively gathered patients from nine centres in Europe and North America treated with ACURATE neo valve through TAx approach up to May/2019. Follow up was pre-specified at 1-year and was obtained for all patients. A total of 75 patients (79 ± 10 years; 32% women) were included. Left axillary (72%) and conscious sedation (95.2%) were the most common setting. Risk scores were higher when right axillary artery and surgical cut-down were selected. Severe complications including valve embolization, coronary obstruction, annulus rupture, and procedural mortality did not occur. Cardiac tamponade occurred in two cases (2.7%) with one requiring conversion to open surgery (1.3%). Bail-out stenting and surgical vascular repair were required in 7 (9.3%) and 3 (4%) cases, respectively. The need for new permanent pacemaker was 8%. Procedural success (96%), in-hospital (2.7%), and 1-year mortality (8%) were comparable in all settings. Only one case (1.3%) complicated with cerebrovascular event and one (1.3%) presented moderate aortic regurgitation before discharge. CONCLUSIONS TAx TAVR procedures with the ACURATE neo valve were presented high success rate and low in-hospital and 1-year mortality.
Collapse
|
13
|
|
14
|
Balloon-expandable Myval transcatheter aortic valve implantation. First experience in Spain. ACTA ACUST UNITED AC 2020; 73:596-597. [PMID: 32376228 DOI: 10.1016/j.rec.2020.01.021] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2019] [Accepted: 01/23/2020] [Indexed: 11/25/2022]
|
15
|
Comparison of Figulla Flex® and Amplatzer™ devices for atrial septal defect closure: A meta-analysis. Cardiol J 2020; 27:524-532. [PMID: 32329042 DOI: 10.5603/cj.a2020.0058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2019] [Revised: 06/30/2019] [Accepted: 07/04/2019] [Indexed: 11/25/2022] Open
Abstract
BACKGROUND Atrial septal defect (ASD) is one of the most common congenital heart diseases. Percutaneous closure is the preferred treatment, but certain complications remain a concern. The most common devices are AMPLATZER™ (ASO) (St. Jude Medical, St. Paul, MN, USA) and Figulla Flex® septal occluders (FSO) (Occlutech GmbH, Jena, Germany). The present study aimed to assess main differences in outcomes. METHODS A systematic search in Pubmed and Google scholarship was performed by two independent reviewers for any study comparing ASO and FSO. Searched terms were "Figulla", "Amplatzer", and "atrial septal defect". A random-effects model was used. RESULTS A total of 11 studies including 1770 patients (897 ASO; 873 FSO) were gathered. Baseline clinical and echocardiographic characteristics were comparable although septal aneurysm was more often reported in patients treated with ASO (32% vs. 25%; p = 0.061). Success rate (94% vs. 95%; OR: 0.81; 95% CI: 0.38-1.71; p = 0.58) and peri-procedural complications were comparable. Procedures were shorter, requiring less fluoroscopy time with an FSO device (OR: 0.59; 95% CI: 0.20-0.97; p = 0.003). Although the global rate of complications in long-term was similar, the ASO device was associated with a higher rate of supraventricular arrhythmias (14.7% vs. 7.8%, p = 0.009). CONCLUSIONS Percutaneous closure of ASD is a safe and effective, irrespective of the type of device. No differences exist regarding procedural success between the ASO and FSO devices but the last was associated to shorter procedure time, less radiation, and lower rate of supraventricular arrhythmias in follow-up. Late cardiac perforation did not occur and death in the follow-up was exceptional.
Collapse
|
16
|
Estratificación basal de riesgo en pacientes mayores de 75 años con infarto y shock cardiogénico referidos para angioplastia primaria. Rev Esp Cardiol (Engl Ed) 2019. [DOI: 10.1016/j.recesp.2018.08.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
17
|
Incidence, Predictors, and Prognostic Value of Acute Kidney Injury Among Patients Undergoing Left Atrial Appendage Closure. JACC Cardiovasc Interv 2019; 11:1074-1083. [PMID: 29880102 DOI: 10.1016/j.jcin.2018.03.022] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/11/2017] [Revised: 03/05/2018] [Accepted: 03/13/2018] [Indexed: 11/17/2022]
Abstract
OBJECTIVES The aims of this registry were to determine the incidence, predictors, and prognostic value of periprocedural acute kidney injury (AKI) after left atrial appendage closure (LAAC). BACKGROUND No data exist on the occurrence of AKI after LAAC. METHODS A total of 355 patients undergoing LAAC were included in the study. AKI was defined as an absolute or a relative increase in serum creatinine of >0.3 mg/dl or ≥50%, respectively, after the procedure or the need for hemodialysis during index hospitalization. RESULTS The incidence of AKI was 9%, and patients with worse baseline renal function were at higher risk for developing AKI (odds ratio: 1.32; 95% confidence interval [CI]: 1.09 to 1.61; p = 0.004 for each 10 ml/min decrease in glomerular filtration rate). In-hospital bleeding events occurred more frequently in the AKI group (5.3% vs. 15.6%; p = 0.037). After a median follow-up period of 18 months, patients in the AKI group had higher mortality (hazard ratio [HR]: 2.59; 95% CI: 1.36 to 4.92; p = 0.004), more embolic events (HR: 6.14; 95% CI: 2.23 to 16.92; p = 0.001) and major bleeding events (HR: 2.36; 95% CI: 0.89 to 6.24; p = 0.083). The occurrence of AKI was an independent predictor of midterm mortality (HR: 2.00; 95% CI: 1.02 to 3.91; p = 0.044). CONCLUSIONS The occurrence of AKI was relatively frequent following LAAC, and patients with lower renal glomerular filtration rates were at high risk for developing this complication. AKI identified a group of patients with worse midterm outcomes, highlighting the importance of further preventive strategies in this population.
Collapse
|
18
|
Fracture of small Mitroflow® aortic bioprosthesis following valve‐in‐valve transcatheter aortic valve replacement with ACURATE neo valve—From bench testing to clinical practice. Catheter Cardiovasc Interv 2019; 95:E120-E122. [DOI: 10.1002/ccd.28347] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/02/2019] [Revised: 03/31/2019] [Accepted: 05/16/2019] [Indexed: 11/06/2022]
|
19
|
Mimicking physiological O2 tension in the female reproductive tract improves assisted reproduction outcomes in pig. Mol Hum Reprod 2019; 24:260-270. [PMID: 29490063 DOI: 10.1093/molehr/gay008] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2017] [Accepted: 02/26/2018] [Indexed: 01/20/2023] Open
Abstract
STUDY QUESTION Is O2 tension in the pig oviduct and uterus affected by the estrous cycle stage and the animal's age, and can the outcome of in vitro embryo development be improved by mimicking these physiological values? SUMMARY ANSWER O2 tension within the pig reproductive organs is affected by the animal's age, and values close to those measured in vivo have a positive impact on embryo development and quality when used during IVF and embryo culture (EC). WHAT IS KNOWN ALREADY To obtain a healthy embryo in vitro, it is necessary to adopt a culture microenvironment that approximates physiological conditions. Despite advances in surgical procedures and sensitive probes that allow accurate assessment of in vivo O2 tension, few such studies have been conducted recently in mammals. In addition, no reference values of physiological O2 tension in the reproductive tract exist for large animal models such as pig, and the effect of O2 tension on ART outcomes is unknown. STUDY DESIGN, SIZE, DURATION This study was conducted in pigs. We measured oviductal and uterine O2 tension (n = 29 and 13, respectively) and then examined how the use of the physiological values in pig IVF and EC affected pig ART output (n = 1447 oocytes). PARTICIPANTS/MATERIALS, SETTING, METHODS The oviductal and uterine O2 tension at the different stages of the estrous cycle was monitored using a laparo-endoscopic single-site surgery (LESS) assisted approach along with a flexible and thin miniaturized luminescent probe. Two groups of pigs, Large-white × Landrace breed, were used: for the first group, 16 pre-pubertal gilts (5 months old and 95 kg) were induced to ovulate with equine chorionic gonadotropin (eCG) and human chorionic gonadotropin (hCG); in the second group 13 mature sows (24-48 months and 185 kg) were used. IVF and EC were performed at two different O2 tensions: Atmospheric O2 (20%) and the mean in vivo value measured (7%). At 18-20 h post-insemination (hpi), a small sample of presumptive zygotes were fixed, stained and examined under epifluorescence microscopy to assess the fertilization rates. At 48 hpi, cleavage was evaluated under the stereomicroscope. Finally, at 180 hpi, development to the blastocyst stage was quantified, blastocyst morphology was assessed, and embryos were fixed and stained to count the mean cell number per blastocyst. MAIN RESULTS AND THE ROLE OF CHANCE The mean O2 content within the pig oviduct and uterus was always lower than in ambient air. The average O2 percentage was higher in gilts (10.0%) than in sows (7.6%) (P < 0.0001). The cleavage rate of porcine in vitro fertilized embryos maintained under 7% O2 during IVF and EC was significantly higher (60.0 ± 2.3) compared with those cultured under 20% O2 (32.0 ± 2.2) (P < 0.05). An increase in the number of cells in embryos cultured under the low O2 concentration (88.9 ± 5.9) was observed compared to those cultured under 20% O2 (59.0 ± 5.0) (P < 0.05). LARGE SCALE DATA None. LIMITATIONS, REASONS FOR CAUTION Although minimally invasive surgery was used the effect of anesthesia and manipulations on O2 tension within the organs are unknown. WIDER IMPLICATIONS OF THE FINDINGS Using physiological oxygen concentrations in IVF/EC could improve ART outcomes. STUDY FUNDING AND COMPETING INTEREST(S) This study was funded by Spanish Ministry of Economy and Competitiveness (MINECO) and European Regional Development Fund (FEDER). Grants AGL2012-40180-C03-01 and AGL2015-66341-R. The authors declare no conflict of interest.
Collapse
|
20
|
<i>Quantitative flow ratio</i> en infarto de miocardio para la evaluaci�n de lesiones en arterias no culpables. Estudio piloto QIMERA. REC: INTERVENTIONAL CARDIOLOGY 2019. [DOI: 10.24875/recic.m19000017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
|
21
|
Device specificity of vascular healing following implantation of bioresorbable vascular scaffolds and bioabsorbable polymer metallic drug-eluting stents in human coronary arteries: the ESTROFA OCT BVS vs. BP-DES study. EUROINTERVENTION 2018; 14:e1295-e1303. [PMID: 29901443 DOI: 10.4244/eij-d-17-00952] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
AIMS We sought to compare vascular healing with bioresorbable everolimus-eluting vascular scaffolds (BVS) and drug-eluting stents with bioabsorbable polymers (BP-DES) at six and 12 months both implanted in the same patients. METHODS AND RESULTS This was a multicentre and prospective study including patients with at least two comparable lesions to treat. In every patient both BVS and BP-DES (SYNERGY, Orsiro or BioMatrix Flex) were implanted by lesion randomisation. Patients included were evaluated with optical coherence tomography at six or 12 months (2:1). Finally, 68 patients had an examination at six months and 27 patients at 12 months. The rates of uncovered struts at six months were 1.7±3.2% for BVS and 5.3±5.6% for BP-DES (p=0.0001), and at 12 months 0.48±0.72% and 4.8±5%, respectively (p=0.001). Rates of strut malapposition were significantly lower with BVS. There was no significant intra-patient correlation with BP-DES/BVS for endpoints. Evaginations were more frequent and larger with BVS. Discontinuities in BVS were observed in 19.4% at six months and 14.3% at 12 months. CONCLUSIONS Vascular healing with BVS and BP-DES could be more device-specific than patient-specific. At follow-up, BVS presented fewer uncovered or non-apposed struts than BP-DES but more frequent and larger evaginations. Discontinuities in BVS were relatively frequent at both time points.
Collapse
|
22
|
Baseline Risk Stratification of Patients Older Than 75 Years With Infarction and Cardiogenic Shock Undergoing Primary Angioplasty. ACTA ACUST UNITED AC 2018; 72:1005-1011. [PMID: 30297278 DOI: 10.1016/j.rec.2018.09.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2018] [Accepted: 08/14/2018] [Indexed: 10/28/2022]
Abstract
BACKGROUND AND OBJECTIVES Patients older than 75 years with ST-segment elevation myocardial infarction undergoing primary angioplasty in cardiogenic shock have high mortality. Identification of preprocedural predictors of short- and long-term mortality could be useful to guide decision-making and further interventions. METHODS We analyzed a nationwide registry of primary angioplasty in the elderly (ESTROFA MI+75) comprising 3576 patients. The characteristics and outcomes of the subgroup of patients in cardiogenic shock were analyzed to identify associated factors and prognostic predictors in order to derive a baseline risk prediction score for 1-year mortality. The score was validated in an independent cohort. RESULTS A total of 332 patients were included. Baseline independent predictors of mortality were anterior myocardial infarction (HR 2.8, 95%CI, 1.4-6.0 P=.005), ejection fraction<40% (HR 2.3, 95%CI, 1.14-4.50 P=.018), and time from symptom onset to angioplasty >6hours (HR 3.2, 95%CI, 1.6-7.5; P=.001). A score was designed that included these predictive factors (score "6-ANT-40"). Survival at 1 year was 54.5% for patients with score 0, 32.3% for score 1, 27.4% for score 2 and 17% for score 3 (P=.004, c-statistic 0.70). The score was validated in an independent cohort of 124 patients, showing 1-year survival rates of 64.5%, 40.0%, 28.9%, and 22.2%, respectively (P=.008, c-statistic 0.68). CONCLUSIONS A preprocedural score based on 3 simple clinical variables (anterior location, ejection fraction<40%, and delay time >6 hours) may be used to estimate survival after primary angioplasty in elderly patients with cardiogenic shock and to guide preinterventional decision-making.
Collapse
|
23
|
Comparación de la hemodinámica valvular de la prótesis transcatéter con balón expandible SAPIEN 3 frente a la autoexpandible Evolut R: estudio de casos emparejados. Rev Esp Cardiol 2018. [DOI: 10.1016/j.recesp.2017.10.032] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
24
|
Functional and Structural Coronary Recovery at the 5-year Follow-up After Bioresorbable Vascular Scaffold Implantation. An Optical Coherence Tomography Analysis. ACTA ACUST UNITED AC 2018; 72:357-359. [PMID: 30905344 DOI: 10.1016/j.rec.2018.04.026] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2018] [Accepted: 04/02/2018] [Indexed: 11/30/2022]
|
25
|
Abstract
AIMS The aim of this study was to describe the incidence, mechanisms, management and outcomes of intracardiac shunts (ICS) following TAVI. METHODS AND RESULTS This was a multicentre registry across 10 centres aimed at gathering all cases of ICS (1.1%) including infection-related (IRICS, 0.3%) or aseptic (AICS, 0.8%) shunts. Patients presented porcelain aorta (24% vs. 6.8%, p=0.024) and had been treated with predilation (88% vs. 68.5%, p=0.037) or post-dilation (59.1% vs. 19.3%, p<0.001) more often. Median time from intervention to diagnosis of ICS was 10 days (IQR: 2-108), being longer for IRICS (171 [63-249] vs. 3 [1-12] days, p=0.002). Interventricular septum (55.6%) and anterior mitral leaflet (57.2%) were the most common locations for AICS and IRICS, respectively. Most patients (76%) developed heart failure but 64% were medically managed. Seven patients (38.9%) underwent percutaneous closure of AICS. The in-hospital mortality rate was 44% (IRICS 100%, AICS 27.8%) compared to global TAVI recipients (8.1%, p<0.001). At one-year follow-up, 76% of the patients had died. ICS, logistic EuroSCORE, and moderate-severe residual aortic regurgitation were independent predictors of death. CONCLUSIONS Post-TAVI ICS are an uncommon complication independently associated with high early mortality. Currently, most therapeutic alternatives yield poor results but percutaneous closure of AICS was feasible and is a promising alternative.
Collapse
|
26
|
Effect of direct intramyocardial autologous stem cell grafting in the sub-acute phase after myocardial infarction. THE JOURNAL OF CARDIOVASCULAR SURGERY 2018; 59:259-267. [PMID: 29582623 DOI: 10.23736/s0021-9509.17.10126-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND To assess the efficacy and safety of intramyocardial autologous bone marrow mononuclear stem cells (BMMNC) grafting combined with coronary artery bypass grafting (CABG) on ventricular remodeling and global and regional wall motion after acute transmural myocardial infarction (AMI). METHODS Randomized controlled trial including 20 patients with non-revascularized transmural AMI, left ventricular ejection fraction (LVEF) lower than 50% and surgical indication for CABG. The stem cell group was treated with BMMNC grafting by direct intramyocardial injection between the 10th and 15th days after AMI (subacute phase) combined with CABG under cardiopulmonary bypass; the control group was only treated with CABG. Magnetic resonance imaging with gadolinium and stress echocardiography were performed presurgery and 9 months postsurgery. RESULTS Seventeen patients completed the follow-up. The baseline characteristics of both groups were homogeneous. No significant differences were found in the increase in LVEF (control: 6.99±4.60, cells: 7.47±6.61, P=0.876) or in the decrease in global (control: 0.28±0.39, cells: 0.22±0.28, P=0.759) or regional (control: 0.52±0.38, cells: 0.74±0.60, P=0.415) wall motion indices between the control and stem cell groups of AMI patients. No differences were found in the recovered non-viable segments (control: 1.29±1.11, cells: 2.50±1.41, P=0.091) or in the decrease in end-diastolic (control: 14.05±19.72, cells: 18.40±29.89, P=0.725) or end-systolic (control: 15.42±13.93, cells: 23.06±25.03, P=0.442) volumes. No complications from stem cell grafting were observed. CONCLUSIONS The results from our study reported herein suggest that intramyocardial BMMNC administration during CABG in patients with AMI causes no medium- to long-term improvement in ventricular remodeling.
Collapse
|
27
|
Transubclavian approach: A competitive access for transcatheter aortic valve implantation as compared to transfemoral. Catheter Cardiovasc Interv 2018; 92:935-944. [DOI: 10.1002/ccd.27485] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/23/2017] [Revised: 10/16/2017] [Accepted: 12/17/2017] [Indexed: 11/11/2022]
|
28
|
Comparison of the Hemodynamic Performance of the Balloon-expandable SAPIEN 3 Versus Self-expandable Evolut R Transcatheter Valve: A Case-matched Study. ACTA ACUST UNITED AC 2017; 71:735-742. [PMID: 29191782 DOI: 10.1016/j.rec.2017.10.025] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2017] [Accepted: 10/06/2017] [Indexed: 11/17/2022]
Abstract
INTRODUCTION AND OBJECTIVES The SAPIEN 3 (S3) valve and the Medtronic Evolut R (EVR) are second-generation transcatheter valves, designed to further reduce the rate of paravalvular aortic regurgitation (AoR). The aim of this study was to compare the 2 devices in terms of valve performance in a case-matched study with independent echocardiographic analysis. METHODS Of a population of 201 patients who underwent transcatheter aortic valve implantation, 144 patients (S3, n = 80; EVR, n = 64) were matched according to aortic annulus diameter and aortic valve calcium score, as assessed by computed tomography. All echocardiographic examinations collected at baseline and at 1- and 6-month follow-up were centrally analyzed. RESULTS The 2 groups were well balanced in baseline clinical and echocardiographic characteristics. The EVR valve showed a better hemodynamic profile as assessed by peak aortic gradient (EVR 13 ± 7 vs S3 20 ± 10mmHg; P<.001), mean aortic gradient (EVR 7 ± 3 vs S3 11 ± 6mmHg; P<.001), and Doppler velocity index (EVR 0.65±0.15 vs S3 0.51±0.16; P<.001). The rate of moderate-severe or any paravalvular (≥ mild) AoR was higher in the EVR group (11% and 50%) than in the S3 group (2.5% and 21%; P <.05, respectively), with a larger number of paravalvular jets (P <.001). CONCLUSIONS In a case-matched cohort of transcatheter aortic valve implantation patients, the S3 valve was associated with a lower rate of paravalvular AoR but also with a higher residual gradient than the EVR system.
Collapse
|
29
|
Resultados funcionales tras entrenamiento fisioterapéutico que incluye la realidad virtual en mayores de 60 años con artroplastia total de cadera: estudio descriptivo. ACTA ACUST UNITED AC 2017. [DOI: 10.1016/j.ft.2017.04.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|
30
|
Bioresorbable Vascular Scaffolds for Patients With In-Stent Restenosis. JACC Cardiovasc Interv 2017; 10:1841-1851. [DOI: 10.1016/j.jcin.2017.06.064] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/09/2017] [Revised: 06/22/2017] [Accepted: 06/22/2017] [Indexed: 10/19/2022]
|
31
|
Expression of the vascular endothelial growth factor system (VEGF) in the porcine oviduct during the estrous cycle. Theriogenology 2017; 93:46-54. [DOI: 10.1016/j.theriogenology.2017.01.028] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2016] [Revised: 01/15/2017] [Accepted: 01/15/2017] [Indexed: 11/25/2022]
|
32
|
Culotte Technique With a Bioresorbable Vascular Scaffold: 12 Months' Follow-up. ACTA ACUST UNITED AC 2016; 69:973-974. [PMID: 27085839 DOI: 10.1016/j.rec.2015.12.030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2015] [Accepted: 12/23/2015] [Indexed: 10/22/2022]
|
33
|
Predictors and Impact of Myocardial Injury After Transcatheter Aortic Valve Replacement. J Am Coll Cardiol 2015; 66:2075-2088. [DOI: 10.1016/j.jacc.2015.08.881] [Citation(s) in RCA: 48] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/27/2015] [Revised: 08/21/2015] [Accepted: 08/28/2015] [Indexed: 10/22/2022]
|
34
|
[Initial experience and valve-in-valve implantation with the balloon-expandable SAPIEN 3 transcatheter prosthesis]. ARCHIVOS DE CARDIOLOGIA DE MEXICO 2015; 86:88-90. [PMID: 26067355 DOI: 10.1016/j.acmx.2015.04.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2015] [Revised: 03/22/2015] [Accepted: 04/27/2015] [Indexed: 11/18/2022] Open
|
35
|
Comparison of Different Bone Marrow–Derived Stem Cell Approaches in Reperfused STEMI. J Am Coll Cardiol 2015; 65:2372-82. [DOI: 10.1016/j.jacc.2015.03.563] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/01/2015] [Revised: 02/23/2015] [Accepted: 03/24/2015] [Indexed: 11/25/2022]
|
36
|
Late Cardiac Death in Patients Undergoing Transcatheter Aortic Valve Replacement. J Am Coll Cardiol 2015; 65:437-48. [DOI: 10.1016/j.jacc.2014.11.027] [Citation(s) in RCA: 172] [Impact Index Per Article: 19.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/26/2014] [Revised: 10/28/2014] [Accepted: 11/04/2014] [Indexed: 11/29/2022]
|
37
|
Bioresorbable scaffold T-stenting evaluated with optical coherence tomography. ACTA ACUST UNITED AC 2014; 67:949. [PMID: 25443817 DOI: 10.1016/j.rec.2014.01.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2013] [Accepted: 01/23/2014] [Indexed: 11/17/2022]
|
38
|
|
39
|
Problemas de un corazón adolescente. Rev Esp Cardiol (Engl Ed) 2011; 64:1223-4. [DOI: 10.1016/j.recesp.2011.02.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2010] [Accepted: 02/07/2011] [Indexed: 11/27/2022]
|
40
|
Absence of accelerated atherosclerotic disease progression after intracoronary infusion of bone marrow derived mononuclear cells in patients with acute myocardial infarction--angiographic and intravascular ultrasound--results from the TErapia Celular Aplicada al Miocardio Pilot study. Am Heart J 2010; 159:1154.e1-8. [PMID: 20569733 DOI: 10.1016/j.ahj.2010.03.030] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/09/2009] [Accepted: 03/20/2010] [Indexed: 10/19/2022]
Abstract
BACKGROUND We tried to evaluate a putative negative effect on coronary atherosclerosis in patients receiving intracoronary infusion of unfractionated bone marrow mononuclear cells (BMMC) following an acute ST-elevation myocardial infarction. Peripheral blood mononuclear cells or enriched CD133(+) BMMC have been associated with accelerated atherosclerosis of the distal segment of the infarct related artery (IRA). METHODS Thirty-seven patients with ST-elevation myocardial infarction from the TECAM pilot study underwent intracoronary infusion of autologous BMMC 9 +/- 3.1 days after onset of symptoms. We compared angiographic changes from baseline to 9 months of follow-up in the distal non-stented segment of the IRA, as well as in the contralateral coronary artery, with a matched control group. A subgroup of 15 treated patients underwent additional IVUS within the distal segment of the IRA. RESULTS No difference between stem cell and control group were found regarding changes in minimum lumen diameter (0.006 +/- 0.42 vs 0.06 +/- 0.41 mm, P = ns) and the percentage of stenosis (-2.68 +/- 12.33% vs -1.78 +/- 8.75%, P = ns) at follow-up. Likewise, no differences were seen regarding changes in the contralateral artery (minimum lumen diameter -0.004 +/- 0.54 mm vs -0.06 +/- 0.35 mm, P = ns). In the intravascular ultrasound substudy, no changes were demonstrated comparing baseline versus follow-up in maximum area stenosis and plaque volume. CONCLUSIONS In this pilot study, analysis of a subgroup of patients found that intracoronary injection of unfractionated BMMC in patients with acute ST-elevation myocardial infarction was not associated with accelerated atherosclerosis progression at mid term. Prospective, randomised studies in large cohorts with long-term angiographic and intravascular ultrasound follow-up are necessary to determine the safety of this therapy.
Collapse
|
41
|
Incidence Of Graft-Versus-Host Disease (GVHD) In Patients With Allogeneic Peripheral Hematopoietic Stem Cell Transplantation After A Non-Myeloablative Conditioning. Biol Blood Marrow Transplant 2010. [DOI: 10.1016/j.bbmt.2009.12.471] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
42
|
Outpatient Haploidentical Stem Cell Transplantation In Pediatric Patients. Preliminary Results In A Single Institution In Mexico. Biol Blood Marrow Transplant 2010. [DOI: 10.1016/j.bbmt.2009.12.419] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
43
|
Optical coherence tomography. Initial experience in patients undergoing percutaneous coronary intervention. Rev Esp Cardiol 2008; 61:976-979. [PMID: 18775241] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Optical coherence tomography is a new intracoronary diagnostic technique that has a higher resolution than other techniques, such as intravascular ultrasound. We used optical coherence tomography to study outcomes after stent implantation in six patients who had undergone percutaneous coronary intervention, and in whom angiography showed normal results after revascularization. Material was observed to protrude through the stent struts in all patients, small dissections were seen at the stent edges in four patients, and there was incomplete stent apposition in four patients. In two patients, small amounts of thrombus were observed to form around the tomography catheter. With optical coherence tomography, it was possible to detect areas in which the results of percutaneous coronary intervention were suboptimal, despite a satisfactory appearance on angiography.
Collapse
|
44
|
Tomografía de coherencia óptica. Experiencia inicial en pacientes sometidos a intervencionismo coronario percutáneo. Rev Esp Cardiol 2008. [DOI: 10.1157/13125521] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
45
|
Carbo-stent liberador de tacrolimus Janus®. Resultados inmediatos y seguimiento clínico a medio plazo. Rev Esp Cardiol 2007. [DOI: 10.1157/13099467] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
46
|
[Janus tacrolimus-eluting carbostent. Immediate and medium-term clinical results]. Rev Esp Cardiol 2007; 60:197-200. [PMID: 17338885] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
This observational and clinical follow-up study involved the first 50 patients who were treated with the Janus tacrolimus-eluting carbostent (Sorin Group) at our hospital. The patients' mean age was 66 (10) years, 38% were diabetic, and 56% were admitted with acute coronary syndrome. In total, 56 lesions were treated (52% were type B2/C), of which 12% involved in-stent restenosis, 5% were chronic occlusions, 23% were long lesions (>20 mm), 25% were in small vessels (< or = 2.5 mm), 7% were aorto-ostial lesions, 5% were in vein grafts, and 14% involved angiographically visible thrombus. Some 63 Janus carbostents were implanted (i.e., 1.26 [0.49] stents/patient). A successful outcome was achieved for all lesions. One patient (2%) required reintervention at the target lesion because of acute thrombosis. During a follow-up period of 10 (3) months, eight (16%) major adverse cardiac events occurred: there was one (2%) death due to heart failure and seven patients (14%) required revascularization, in five (10%) cases because of restenosis of the Janus carbostent.
Collapse
|
47
|
|
48
|
[Neuropsychological and pathobiographical sketches of General Rafael Urdaneta]. REVISTA DE LA SOCIEDAD VENEZOLANA DE HISTORIA DE LA MEDICINA 2001; 37:147-59. [PMID: 11640728] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/22/2023]
|
49
|
Unusually high prevalence rates of obesity in four Mexican rural communities. Eur J Clin Nutr 2001; 55:833-40. [PMID: 11593344 DOI: 10.1038/sj.ejcn.1601238] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2000] [Revised: 03/15/2001] [Accepted: 03/19/2001] [Indexed: 11/09/2022]
Abstract
OBJECTIVE To establish the nutritional status of previously studied rural populations. DESIGN AND SUBJECTS A total of 139 households with 245 males and 301 females from four relatively isolated Mexican rural communities were randomly selected to be surveyed in 1996. RESULTS Underweight was not a problem in either children or adults. In children <5 y only three (4.2%) were stunted but the age- and sex-specific distributions of body mass index (BMI) in children showed 17% of boys and 19% of girls exceeded the proposed International Obesity Task Force limits for classifying the overweight. Triceps skinfold values were similar to NHANESI values for white USA children. Of the adult men 42% were overweight (BMI 25.0-29.9) and 9% obese; 40% of adult women were overweight and a further 33% obese. Adjusting BMI values with corrected total heights by relating them to measured knee height reduced the BMI of women >50 y by 2.0 units; the male data were essentially unchanged. The prevalence of abdominal obesity in women, based on waist measurements and WHO cut-off points was high with 25% of women having elevated values despite a normal BMI; 43% of the overweight women had substantial increases in waist measurements, indicative of high risk, as did 91% of obese women. The men's waist measurements were greater in relation to both BMI and body fat but the prevalence of values in excess of the suggested sex-specific WHO limits was less than half that of women. CONCLUSIONS The high prevalence of overweight and obesity is now evident in poor and relatively isolated rural communities of Mexico. SPONSORSHIP The Chronic Disease Office, from the Ministry of Health in Mexico partially financed this study.
Collapse
|
50
|
Differential participation of the NBM in the acquisition and retrieval of conditioned taste aversion and Morris water maze. Behav Brain Res 2000; 116:89-98. [PMID: 11090888 DOI: 10.1016/s0166-4328(00)00250-3] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Deficits in both learning and memory after lesions of the cholinergic basal forebrain, in particular the nucleus basalis magnocellularis (NBM), have been widely reported. However, the participation of the cholinergic system in either acquisition or retrieval of memory process is still unclear. In this study, we tested the possibility that excitotoxic lesions of the NBM affect either acquisition or retrieval of two tasks. In the first experiment, animals were trained for two conditioned taste aversion tasks using different flavors, saccharine and saline. The acquisition of the first task was before NBM lesions (to test retrieval) and the acquisition of the second task was after the lesions (to test acquisition). Accordingly, in the first part of the second experiment, animals were trained in the Morris water maze (MWM), lesioned and finally tested. In the final part of this experiment, another set of animals was lesioned, then trained in the MWM and finally tested. All animals were able to retrieve conditioned taste aversion (CTA) and MWM when learned before NBM lesions; however, lesions disrupted the acquisition of CTA and MWM. The results suggest that the NBM and cholinergic system may play an important role in acquisition but not during retrieval of aversive memories.
Collapse
|