1
|
Molenaar R, Prangsma JC, van der Werf KO, Bennink ML, Blum C, Subramaniam V. Microcantilever based distance control between a probe and a surface. Rev Sci Instrum 2015; 86:063706. [PMID: 26133843 DOI: 10.1063/1.4922885] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
We demonstrate a method to control the distance between a custom probe and a sample on a μm to nm scale. The method relies on the closed-loop feedback on the angular deflection of an in-contact AFM microcantilever. High performance in stability and accuracy is achieved in this method by taking advantage of the small mechanical feedback path between surface and probe. We describe how internal error sources that find their origin in the microcantilever and feedback can be minimized to achieve an accurate and precise control up to 3 nm. In particular, we investigated how hysteresis effects in the feedback caused by friction forces between tip and substrate can be minimized. By applying a short calibration procedure, distance control from contact to several micrometers probe-sample distance can be obtained with an absolute nanometer-scale accuracy. The method presented is compatible with any probe that can be fixed on a microcantilever chip and can be easily built into existing AFM systems.
Collapse
Affiliation(s)
- R Molenaar
- Nanobiophysics Group, MESA+ Institute for Nanotechnology and MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, P.O. Box 217, 7500AE Enschede, The Netherlands
| | - J C Prangsma
- Nanobiophysics Group, MESA+ Institute for Nanotechnology and MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, P.O. Box 217, 7500AE Enschede, The Netherlands
| | - K O van der Werf
- Nanobiophysics Group, MESA+ Institute for Nanotechnology and MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, P.O. Box 217, 7500AE Enschede, The Netherlands
| | - M L Bennink
- Nanobiophysics Group, MESA+ Institute for Nanotechnology and MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, P.O. Box 217, 7500AE Enschede, The Netherlands
| | - C Blum
- Nanobiophysics Group, MESA+ Institute for Nanotechnology and MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, P.O. Box 217, 7500AE Enschede, The Netherlands
| | - V Subramaniam
- Nanobiophysics Group, MESA+ Institute for Nanotechnology and MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, P.O. Box 217, 7500AE Enschede, The Netherlands
| |
Collapse
|
2
|
Yang L, van der Werf KO, Dijkstra PJ, Feijen J, Bennink ML. Micromechanical analysis of native and cross-linked collagen type I fibrils supports the existence of microfibrils. J Mech Behav Biomed Mater 2011; 6:148-58. [PMID: 22301184 DOI: 10.1016/j.jmbbm.2011.11.008] [Citation(s) in RCA: 58] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2011] [Revised: 11/10/2011] [Accepted: 11/16/2011] [Indexed: 01/28/2023]
Abstract
The mechanical properties of individual collagen fibrils of approximately 200 nm in diameter were determined using a slightly adapted AFM system. Single collagen fibrils immersed in PBS buffer were attached between an AFM cantilever and a glass surface to perform tensile tests at different strain rates and stress relaxation measurements. The stress-strain behavior of collagen fibrils immersed in PBS buffer comprises a toe region up to a stress of 5 MPa, followed by the heel and linear region at higher stresses. Hysteresis and strain-rate dependent stress-strain behavior of collagen fibrils were observed, which suggest that single collagen fibrils have viscoelastic properties. The stress relaxation process of individual collagen fibrils could be best fitted using a two-term Prony series. Furthermore, the influence of different cross-linking agents on the mechanical properties of single collagen fibrils was investigated. Based on these results, we propose that sliding of microfibrils with respect to each other plays a role in the viscoelastic behavior of collagen fibrils in addition to the sliding of collagen molecules with respect to each other. Our finding provides a better insight into the relationship between the structure and mechanical properties of collagen and the micro-mechanical behavior of tissues.
Collapse
Affiliation(s)
- L Yang
- Polymer Chemistry and Biomaterials, Faculty of Science & Technology and Institute for Biomedical Technology and Technical Medicine (MIRA), University of Twente, P.O. Box 217, 7500 AE, Enschede, The Netherlands
| | | | | | | | | |
Collapse
|
3
|
Huisstede JHG, van der Werf KO, Bennink ML, Subramaniam V. Force constant calibration corrections for silicon position detectors in the near-infrared. Opt Express 2006; 14:8476-8481. [PMID: 19529225 DOI: 10.1364/oe.14.008476] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
The accurate calibration of the force constant of the probe in atomic force microscopy and optical tweezers applications is extremely important for force spectroscopy. The commonly used silicon detectors exhibit a complex transfer function for wavelengths >850 nm, which limits the detection bandwidth leading to serious errors in the force constant determination. We show that this low-pass effect can be compensated for using the frequency response of the detector. This is applicable for calibrations in both atomic force microscopy and optical tweezers. For optical tweezers an additional correction method is discussed based on fitting an expression in which the low-pass characteristics are already accounted for.
Collapse
|
4
|
Hopman WCL, van der Werf KO, Hollink AJF, Bogaerts W, Subramaniam V, de Ridder RM. Nano-mechanical tuning and imaging of a photonic crystal micro-cavity resonance. Opt Express 2006; 14:8745-8752. [PMID: 19529256 DOI: 10.1364/oe.14.008745] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
We show that nano-mechanical interaction using atomic force microscopy (AFM) can be used to map out mode-patterns of an optical micro-resonator with high spatial accuracy. Furthermore we demonstrate how the Q-factor and center wavelength of such resonances can be sensitively modified by both horizontal and vertical displacement of an AFM tip consisting of either Si(3)N(4) or Si material. With a silicon tip we are able to tune the resonance wavelength by 2.3 nm, and to set Q between values of 615 and zero, by expedient positioning of the AFM tip. We find full on/off switching for less than 100 nm vertical, and for 500 nm lateral displacement at the strongest resonance antinode locations.
Collapse
|
5
|
Huisstede JHG, van Rooijen BD, van der Werf KO, Bennink ML, Subramaniam V. Dependence of silicon position-detector bandwidth on wavelength, power, and bias. Opt Lett 2006; 31:610-2. [PMID: 16570414 DOI: 10.1364/ol.31.000610] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
We have developed a two-LED wobbler system to generate the spatial displacement of total light intensity on a detector surface, facilitating the acquisition of frequency responses up to 600 kHz with high accuracy. We have used this setup to characterize the low-pass filtering behavior of silicon-based position detectors for wavelengths above 850 nm by acquiring the frequency responses of several quadrant detectors and position-sensitive detectors as functions of wavelength, applied bias voltage, and total light power. We observed an increase in bandwidth for an increase in applied bias voltage and incident-light intensity. The combined effect of these parameters is strongly dependent on the detector used and has significant implications for the use of these detectors in scanning probe and optical tweezers applications.
Collapse
Affiliation(s)
- J H G Huisstede
- Biophysical Engineering and MESA + Institute for Nanotechnology, Department of Science and Technology, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands.
| | | | | | | | | |
Collapse
|
6
|
Kassies R, van der Werf KO, Lenferink A, Hunter CN, Olsen JD, Subramaniam V, Otto C. Combined AFM and confocal fluorescence microscope for applications in bio-nanotechnology. J Microsc 2005; 217:109-16. [PMID: 15655068 DOI: 10.1111/j.0022-2720.2005.01428.x] [Citation(s) in RCA: 125] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
We present a custom-designed atomic force fluorescence microscope (AFFM), which can perform simultaneous optical and topographic measurements with single molecule sensitivity throughout the whole visible to near-infrared spectral region. Integration of atomic force microscopy (AFM) and confocal fluorescence microscopy combines the high-resolution topographical imaging of AFM with the reliable (bio)-chemical identification capability of optical methods. The AFFM is equipped with a spectrograph enabling combined topographic and fluorescence spectral imaging, which significantly enhances discrimination of spectroscopically distinct objects. The modular design allows easy switching between different modes of operation such as tip-scanning, sample-scanning or mechanical manipulation, all of which are combined with synchronous optical detection. We demonstrate that coupling the AFM with the fluorescence microscope does not compromise its ability to image with a high spatial resolution. Examples of several modes of operation of the AFFM are shown using two-dimensional crystals and membranes containing light-harvesting complexes from the photosynthetic bacterium Rhodobacter sphaeroides.
Collapse
Affiliation(s)
- R Kassies
- BMTI Institute for Biomedical Technology, University of Twente, PO Box 217, 7500 AE Enschede, The Netherlands
| | | | | | | | | | | | | |
Collapse
|
7
|
Willemsen OH, Snel MM, van Noort SJ, van der Werf KO, de Grooth BG, Figdor CG, Greve J. Optimization of adhesion mode atomic force microscopy resolves individual molecules in topography and adhesion. Ultramicroscopy 1999; 80:133-44. [PMID: 10526398 DOI: 10.1016/s0304-3991(99)00099-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
The force sensor of an atomic force microscope (AFM) is sensitive enough to measure single molecular binding strengths by means of a force-distance curve. In order to combine high-force sensitivity with the spatial resolution of an AFM in topography mode, adhesion mode has been developed. Since this mode generates a force-distance curve for every pixel of an image, the measurement speed in liquid is limited by the viscous drag of the cantilever. We have equipped our adhesion mode AFM with a cantilever that has a low viscous drag in order to reach pixel frequencies of 65 Hz. Optimized filtering techniques combined with an auto-zero circuitry that reduces the drift in the deflection signal, limited high- and low-frequency fluctuations in the height signal to 0.3 nm. This reduction of the height noise, in combination with a thermally stabilized AFM, allowed the visualization of individual molecules on mica with an image quality comparable to tapping mode. The lateral resolution in both the topography and the simultaneously recorded adhesion image are only limited by the size of the tip. Hardware and software position feedback systems allows individual molecules to be followed in time during more than 30 min with scan sizes down to 60 x 60 nm2.
Collapse
Affiliation(s)
- O H Willemsen
- Department of Applied Physics, University of Twente, Enschede, The Netherlands
| | | | | | | | | | | | | |
Collapse
|
8
|
Willemsen OH, Snel MM, van der Werf KO, de Grooth BG, Greve J, Hinterdorfer P, Gruber HJ, Schindler H, van Kooyk Y, Figdor CG. Simultaneous height and adhesion imaging of antibody-antigen interactions by atomic force microscopy. Biophys J 1998; 75:2220-8. [PMID: 9788917 PMCID: PMC1299896 DOI: 10.1016/s0006-3495(98)77666-0] [Citation(s) in RCA: 178] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Specific molecular recognition events, detected by atomic force microscopy (AFM), so far lack the detailed topographical information that is usually observed in AFM. We have modified our AFM such that, in combination with a recently developed method to measure antibody-antigen recognition on the single molecular level (Hinterdorfer, P., W. Baumgartner, H. J. Gruber, K. Schilcher, and H. Schindler, Proc. Natl. Acad. Sci. USA 93:3477-3481 (1996)), it allows imaging of a submonolayer of intercellular adhesion molecule-1 (ICAM-1) in adhesion mode. We demonstrate that for the first time the resolution of the topographical image in adhesion mode is only limited by tip convolution and thus comparable to tapping mode images. This is demonstrated by imaging of individual ICAM-1 antigens in both the tapping mode and the adhesion mode. The contrast in the adhesion image that was measured simultaneously with the topography is caused by recognition between individual antibody-antigen pairs. By comparing the high-resolution height image with the adhesion image, it is possible to show that specific molecular recognition is highly correlated with topography. The stability of the improved microscope enabled imaging with forces as low as 100 pN and ultrafast scan speed of 22 force curves per second. The analysis of force curves showed that reproducible unbinding events on subsequent scan lines could be measured.
Collapse
Affiliation(s)
- O H Willemsen
- Department of Applied Physics, Applied Optics Group, University of Twente, Enschede, The Netherlands
| | | | | | | | | | | | | | | | | | | |
Collapse
|
9
|
Agronskaia A, Florians A, van der Werf KO, Schins JM, de Grooth BG, Greve J. Photon-counting device compatible with conventional flow cytometric data acquisition electronics. Cytometry 1998; 32:255-9. [PMID: 9667515] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
We present an electronic scheme that enables us to use a photon-counting device (photomultiplier or avalanche photodetector) for measuring extremely weak signals in a flow cytometer. It can be used as a sole detector, or in combination with other (conventional) detectors using the data acquisition hardware of a conventional flow cytometer. The essential principle is that photon-counting pulses are converted to an analogue signal that is continuously proportional to the number of detected photons during the last integration time. The integration time should be approximately equal to the time an object is illuminated in the flow chamber. In this way, the photon burst due to real events is measured correctly and discriminated from the background pulses (fluorescence and Raman). The use of this scheme for the measurement of single DNA molecules is illustrated.
Collapse
Affiliation(s)
- A Agronskaia
- Department of Applied Physics, University of Twente, Enschede, The Netherlands
| | | | | | | | | | | |
Collapse
|
10
|
van Noort SJ, van der Werf KO, Eker AP, Wyman C, de Grooth BG, van Hulst NF, Greve J. Direct visualization of dynamic protein-DNA interactions with a dedicated atomic force microscope. Biophys J 1998; 74:2840-9. [PMID: 9635738 PMCID: PMC1299625 DOI: 10.1016/s0006-3495(98)77991-3] [Citation(s) in RCA: 81] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
Photolyase DNA interactions and the annealing of restriction fragment ends are directly visualized with the atomic force microscope (AFM). To be able to interact with proteins, DNA must be loosely bound to the surface. When MgCl2 is used to immobilize DNA to mica, DNA is attached to the surface at distinct sites. The pieces of DNA in between are free to move over the surface and are available for protein interaction. After implementation of a number of instrumental improvements, the molecules can be visualized routinely, under physiological conditions and with molecular resolution. Images are acquired reproducibly without visible damage for at least 30 min, at a scan rate of 2 x 2 microm2/min and a root mean square noise of less than 0.2 nm. Nonspecific photolyase DNA complexes were visualized, showing association, dissociation, and movement of photolyase over the DNA. The latter result suggests a sliding mechanism by which photolyase can scan DNA for damaged sites. The experiments illustrate the potential that AFM presents for modern molecular biology.
Collapse
Affiliation(s)
- S J van Noort
- Department of Applied Physics, University of Twente, Enschede, The Netherlands.
| | | | | | | | | | | | | |
Collapse
|
11
|
Abstract
Investigations have been performed on the dynamics of a distance regulation system based on an oscillating probe at resonance. This was examined at a tuning fork shear-force feedback system, which is used as a distance control mechanism in near-field scanning optical microscopy. In this form of microscopy, a tapered optical fiber is attached to the tuning fork and scanned over the sample surface to be imaged. Experiments were performed measuring both amplitude and phase of the oscillation of the tuning fork as a function of driving frequency and tip-sample distance. These experiments reveal that the resonance frequency of the tuning fork changes upon approaching the sample. Both the amplitude and the phase of the tuning fork can be used as distance control parameter in the feedback system. Using the amplitude a second-order behavior is observed, while with phase only a first-order behavior is observed. Numerical calculations confirm these observations. This first-order behavior results in an improved stability of the feedback system. As an example, a sample consisting of DNA strands on mica was imaged which showed the height of the DNA as 1.4 +/- 0.2 nm.
Collapse
Affiliation(s)
- A G Ruiter
- Department of Applied Physics, University of Twente, AE Enschede, The Netherlands.
| | | | | | | | | | | |
Collapse
|
12
|
Putman CA, van der Werf KO, de Grooth BG, van Hulst NF, Greve J. Viscoelasticity of living cells allows high resolution imaging by tapping mode atomic force microscopy. Biophys J 1994; 67:1749-53. [PMID: 7819507 PMCID: PMC1225537 DOI: 10.1016/s0006-3495(94)80649-6] [Citation(s) in RCA: 158] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023] Open
Abstract
Application of atomic force microscopy (AFM) to biological objects and processes under physiological conditions has been hampered so far by the deformation and destruction of the soft biological materials invoked. Here we describe a new mode of operation in which the standard V-shaped silicon nitride cantilever is oscillated under liquid and damped by the interaction between AFM tip and sample surface. Because of the viscoelastic behavior of the cellular surface, cells effectively "harden" under such a tapping motion at high frequencies and become less susceptible to deformation. Images obtained in this way primarily reveal the surface structure of the cell. It is now possible to study physiological processes, such as cell growth, with a minimal level of perturbation and high spatial resolution (approximately 20 nm).
Collapse
Affiliation(s)
- C A Putman
- Department of Applied Physics, University of Twente, Enschede, The Netherlands
| | | | | | | | | |
Collapse
|
13
|
Neagu C, van der Werf KO, Putman CA, Kraan YM, de Grooth BG, van Hulst NF, Greve J. Analysis of immunolabeled cells by atomic force microscopy, optical microscopy, and flow cytometry. J Struct Biol 1994; 112:32-40. [PMID: 8031640 DOI: 10.1006/jsbi.1994.1004] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
In this study we investigated the applicability of the (silver-enhanced) immunogold labeling method for atomic force microscopy. Human lymphocytes were labeled with anti-CD3 conjugated to fluorescein isothiocyanate and a secondary antibody (goat anti-mouse) linked with 1- or 30-nm colloidal gold particles. Silver enhancement was applied on these labeled cells to increase the size of the labels. In a setup combining an inverted optical microscope and a stand-alone atomic force microscope, a direct correlation was made between the force and the fluorescent images. Additionally, we performed flow cytometric analysis. From the results we conclude that immunogold labeling using small labels (1 nm) in combination with silver enhancement (30 min) proves to be a reliable method for high-resolution cell surface antigen detection in atomic force microscopy.
Collapse
Affiliation(s)
- C Neagu
- MESA-Research Institute, University of Twente, Enschede, The Netherlands
| | | | | | | | | | | | | |
Collapse
|
14
|
van Graft M, Oosterhuis B, van der Werf KO, de Grooth BG, Greve J. A simple optical fiber device for quantitative fluorescence microscopy of single living cells. J Immunol Methods 1993; 159:145-51. [PMID: 8445247 DOI: 10.1016/0022-1759(93)90152-w] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
A simple and relatively inexpensive system is described for obtaining quantitative fluorescence measurements on single living cells loaded with a fluorescent probe to study cell physiological processes. The light emitted from the fluorescent cells is captured by and transported through an optical fiber. After passage through appropriate filters the light is measured using a photomultiplier tube. The optical fiber is mounted in one of the microscope outlets. Signals derived from the photomultiplier are converted to voltage, amplified, and displayed on a recorder. In the excitation pathway a shutter control unit is mounted. With this control unit the period that the excitation pathway is 'opened' and 'closed' can be adjusted, to reduce cell damage and/or bleaching of the probe. This option allows time-lapse recording of experiments up to 1 h. We have used this set-up with a single and dual emission fluorescent probe to determine intracellular calcium concentrations and pH, respectively. In Fluo-3-loaded K562 target cells bound to natural killer cells, a temporary rise in [Ca2+]i was accompanied by bleb formation. The simple construction of this set-up is interchangeable between different types of fluorescence microscopes and can easily be combined with other microscopy techniques, e.g., patch clamp.
Collapse
Affiliation(s)
- M van Graft
- Department of Applied Physics, University of Twente, Enschede, Netherlands
| | | | | | | | | |
Collapse
|