1
|
Raymenants J, Geenen C, Budts L, Thibaut J, Thijssen M, De Mulder H, Gorissen S, Craessaerts B, Laenen L, Beuselinck K, Ombelet S, Keyaerts E, André E. Indoor air surveillance and factors associated with respiratory pathogen detection in community settings in Belgium. Nat Commun 2023; 14:1332. [PMID: 36898982 PMCID: PMC10005919 DOI: 10.1038/s41467-023-36986-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2022] [Accepted: 02/27/2023] [Indexed: 03/12/2023] Open
Abstract
Currently, the real-life impact of indoor climate, human behaviour, ventilation and air filtration on respiratory pathogen detection and concentration are poorly understood. This hinders the interpretability of bioaerosol quantification in indoor air to surveil respiratory pathogens and transmission risk. We tested 341 indoor air samples from 21 community settings in Belgium for 29 respiratory pathogens using qPCR. On average, 3.9 pathogens were positive per sample and 85.3% of samples tested positive for at least one. Pathogen detection and concentration varied significantly by pathogen, month, and age group in generalised linear (mixed) models and generalised estimating equations. High CO2 and low natural ventilation were independent risk factors for detection. The odds ratio for detection was 1.09 (95% CI 1.03-1.15) per 100 parts per million (ppm) increase in CO2, and 0.88 (95% CI 0.80-0.97) per stepwise increase in natural ventilation (on a Likert scale). CO2 concentration and portable air filtration were independently associated with pathogen concentration. Each 100ppm increase in CO2 was associated with a qPCR Ct value decrease of 0.08 (95% CI -0.12 to -0.04), and portable air filtration with a 0.58 (95% CI 0.25-0.91) increase. The effects of occupancy, sampling duration, mask wearing, vocalisation, temperature, humidity and mechanical ventilation were not significant. Our results support the importance of ventilation and air filtration to reduce transmission.
Collapse
Affiliation(s)
- Joren Raymenants
- Laboratory of Clinical Microbiology, KU Leuven, Herestraat 49, 3000, Leuven, Belgium.
- Department of General Internal Medicine, University Hospitals Leuven, Herestraat 49, 3000, Leuven, Belgium.
| | - Caspar Geenen
- Laboratory of Clinical Microbiology, KU Leuven, Herestraat 49, 3000, Leuven, Belgium
| | - Lore Budts
- Department of Laboratory Medicine, National Reference Center of Respiratory Pathogens, University Hospitals Leuven, Herestraat 49, 3000, Leuven, Belgium
| | - Jonathan Thibaut
- Laboratory of Clinical Microbiology, KU Leuven, Herestraat 49, 3000, Leuven, Belgium
| | - Marijn Thijssen
- Laboratory of Clinical and Epidemiological Virology (Rega Institute), KU Leuven, Herestraat 49, 3000, Leuven, Belgium
| | - Hannelore De Mulder
- Laboratory of Clinical Microbiology, KU Leuven, Herestraat 49, 3000, Leuven, Belgium
| | - Sarah Gorissen
- Laboratory of Clinical Microbiology, KU Leuven, Herestraat 49, 3000, Leuven, Belgium
| | - Bastiaan Craessaerts
- Department of Laboratory Medicine, National Reference Center of Respiratory Pathogens, University Hospitals Leuven, Herestraat 49, 3000, Leuven, Belgium
| | - Lies Laenen
- Laboratory of Clinical Microbiology, KU Leuven, Herestraat 49, 3000, Leuven, Belgium
- Department of Laboratory Medicine, National Reference Center of Respiratory Pathogens, University Hospitals Leuven, Herestraat 49, 3000, Leuven, Belgium
| | - Kurt Beuselinck
- Department of Laboratory Medicine, National Reference Center of Respiratory Pathogens, University Hospitals Leuven, Herestraat 49, 3000, Leuven, Belgium
| | - Sien Ombelet
- Department of Laboratory Medicine, National Reference Center of Respiratory Pathogens, University Hospitals Leuven, Herestraat 49, 3000, Leuven, Belgium
| | - Els Keyaerts
- Department of Laboratory Medicine, National Reference Center of Respiratory Pathogens, University Hospitals Leuven, Herestraat 49, 3000, Leuven, Belgium
| | - Emmanuel André
- Laboratory of Clinical Microbiology, KU Leuven, Herestraat 49, 3000, Leuven, Belgium
- Department of Laboratory Medicine, National Reference Center of Respiratory Pathogens, University Hospitals Leuven, Herestraat 49, 3000, Leuven, Belgium
| |
Collapse
|