Kotzerke J, van den Hoff J, Burchert W, Wagner TF, Emter M, Hundeshagen H. A compartmental model for alveolar clearance of pertechnegas.
J Nucl Med 1996;
37:2066-71. [PMID:
8970536]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023] Open
Abstract
UNLABELLED
The washout of an inhaled water soluble radiotracer from the lungs is a measure of alveolar integrity. Data evaluation of 99mTc-DTPA studies were previously performed mainly with monoexponential fitting with or without background subtraction. The introduction of 99mTc-pertechnegas for the assessment of alveolar permeability necessitates the investigation of adequate data evaluation schemes for this radiotracer.
METHODS
We developed a three-compartmental model to describe 99mTc-pertechnegas kinetics after inhalation. Monoexponential fitting of the first 5 min was investigated as simplification for clinical use. Different background corrections based on blood samples or representative regions of interest were compared.
RESULTS
Correction of intra- and extravascular background by subtraction of calibrated curves, which are derived from blood or background areas, resulted in monoexponential washout curves. Clearance rates based on the three-compartmental model were nearly the same as those derived from a monoexponential fit after blood-activity subtraction (r = 0.96). A monoexponential analysis of the first 5 min without any background correction correlates well with the first component of the biexponential analysis (r = 0.97).
CONCLUSION
A dynamic study of more than 45 min allows quantitative determination of the transfer rate of 99mTc-pertechnegas from the alveoli into the blood using compartmental analysis. A simplified monoexponential analysis of the first 5 min allows assessment of lung clearance without any background correction.
Collapse