The primary stability of two dental implant systems in low-density bone. Int J Oral Maxillofac Surg 2022; 51:1093-1100. [PMID: 35339332 DOI: 10.1016/j.ijom.2022.02.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Revised: 02/18/2022] [Accepted: 02/23/2022] [Indexed: 11/19/2022]
Abstract
Primary stability in low-density bone is crucial for the long-term success of implants. Tapered implants have shown particularly favourable properties under such conditions. The aim of this study was to compare the primary stability of tapered titanium and novel cylindrical zirconia dental implant systems in low-density bone. Fifty implants (25 tapered, 25 cylindrical) were placed in the anterior maxillary bone of cadavers meeting the criteria of low-density bone. The maximum insertion (ITV) and removal (RTV) torque values were recorded, and the implant stability quotients (ISQ) determined. To establish the isolated influence of cancellous bone on primary stability, the implantation procedure was performed in standardized low-density polyurethane foam bone blocks (cancellous bone model) using the same procedure. The primary stability parameters of both implant types showed significant positive correlations with bone density (Hounsfield units) and cortical thickness. In the cadaver, the cylindrical zirconia implants showed a significantly higher mean ISQ when compared to the tapered titanium implants (50.58 vs 37.26; P < 0.001). Pearson analysis showed significant positive correlations between ITV and ISQ (P = 0.016) and between RTV and ISQ (P = 0.035) for the cylindrical zirconia implants; no such correlations were observed for the tapered titanium implants. Within the limitations of this study, the results indicate that cylindrical zirconia implants represent a comparable viable treatment option to tapered titanium implants in terms of primary implant stability in low-density human bone.
Collapse
|
2
|
Evaluation of symmetry behavior of surgically assisted rapid maxillary expansion with simulation-driven targeted bone weakening. Clin Oral Investig 2021; 25:6717-6728. [PMID: 33948683 PMCID: PMC8602202 DOI: 10.1007/s00784-021-03958-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2020] [Accepted: 04/19/2021] [Indexed: 11/08/2022]
Abstract
OBJECTIVES Surgically assisted rapid maxillary expansion (SARME) is a treatment modality to overcome maxillary constrictions. During the procedure of transverse expansion, unwanted asymmetries can occur. This retrospective study investigates the transverse expansion behavior of the maxilla utilizing a simulation-driven SARME with targeted bone weakening. MATERIALS AND METHODS Cone beam computer tomographies of 21 patients before (T1) and 4 months after treatment (T2) with simulation-driven SARME combined with a transpalatal distractor (TPD) and targeted bone weakening were superimposed. The movements of the left, right, and frontal segments were evaluated at the modified WALA ridge, mid root level, and at the root tip of all upper teeth. Linear and angular measurements were performed to detect dentoalveolar changes. RESULTS Dentoalveolar changes were unavoidable, and buccal tipping of the premolars (6.1° ± 5.0°) was significant (p < 0.05). Transverse expansion in premolar region was higher (6.13 ± 4.63mm) than that in the molar region (4.20 ± 4.64mm). Expansion of left and right segments did not differ significantly (p > 0.05). CONCLUSION Simulation-driven SARME with targeted bone weakening is effective to achieve symmetrical expansion in the transverse plane. CLINICAL RELEVANCE Simulation-driven targeted bone weakening is a novel method for SARME to achieve symmetric expansion. Dental side effects cannot be prohibited.
Collapse
|
3
|
Fluoride release from two types of fluoride-containing orthodontic adhesives: Conventional versus resin-modified glass ionomer cements-An in vitro study. PLoS One 2021; 16:e0247716. [PMID: 33635885 PMCID: PMC7909673 DOI: 10.1371/journal.pone.0247716] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2020] [Accepted: 02/12/2021] [Indexed: 11/18/2022] Open
Abstract
INTRODUCTION Development of white spot lesions (WSLs) during orthodontic treatment is a common risk factor. Fixation of the orthodontic appliances with glass ionomer cements could reduce the prevalence of WSL's due to their fluoride release capacities. The purpose of this study was to evaluate differences of fluoride release properties from resin-modified and conventional glass ionomer cements (GICs). METHODS The resin-modified GICs Fuji ORTHO LC (GC Orthodontics), Meron Plus QM (VOCO), as well as the conventional GICs Fuji ORTHO (GC Orthodontics), Meron (VOCO) and Ketac Cem Easymix (3M ESPE) were tested in this study. The different types of GICs were applied to hydroxyapatite discs according to the manufacturer's instructions and stored in a solution of TISAB III (Total Ionic Strength Adjustment Buffer III) and fluoride-free water at 37°C. Fluoride measurements were made after 5 minutes, 2 hours, 24 hours, 14 days, 28 days, 2 months, 3 months and 6 months. One factor analysis of variance (ANOVA) was used for the overall comparison of the cumulative fluoride release (from measurement times of 5 minutes to 6 months) between the different materials with the overall level of significance set to 0.05. Tukey's post hoc test was used for post hoc pairwise comparisons in the cumulative fluoride release between the different materials. RESULTS The cumulative fluoride release (mean ± sd) in descending order was: Fuji ORTHO LC (221.7 ± 10.29 ppm), Fuji ORTHO (191.5 ± 15.03 ppm), Meron Plus QM (173.0 ± 5.89 ppm), Meron (161.3 ± 7.84 ppm) and Ketac Cem Easymix (154.6 ± 6.09 ppm) within 6 months. Analysis of variance detected a significant difference in the cumulative fluoride release between at least two of the materials (rounded p-value < 0.001). Pairwise analysis with Tukey's post hoc test showed a significant difference in the cumulative fluoride release for all the comparisons except M and MPQM (p = 0.061) and KCE and M (p = 0.517). CONCLUSION Fluoride ions were released cumulatively over the entire test period for all products. When comparing the two products from the same company (Fuji ORTHO LC vs. Fuji ORTHO from GC Orthodontics Europe GmbH and Meron Plus QM vs. Meron from VOCO GmbH, Mannheim, Germany), it can be said that the resin-modified GICs have a higher release than conventional GICs. The highest individual fluoride release of all GICs was at 24 hours. A general statement, whether resin-modified or conventional GICs have a higher release of fluoride cannot be made.
Collapse
|
4
|
The effect of zirconia and titanium surfaces on biofilm formation and on host-derived immunological parameters. Int J Oral Maxillofac Surg 2021; 50:1361-1374. [PMID: 33618967 DOI: 10.1016/j.ijom.2021.01.021] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2020] [Revised: 01/26/2021] [Accepted: 01/27/2021] [Indexed: 01/15/2023]
Abstract
The aim of this study was to analyse the effect of zirconia and titanium surfaces on biofilm formation and host-derived parameters. Studies comparing zirconia and titanium surfaces were selected up to September 1, 2019. The outcome measures were surface roughness, contact angle, bacterial count, bacterial adherence, biofilm thickness, bacterial distribution, and specifically investigated biofilm and specific host-derived immunological parameters. Random-effects meta-analyses of in vitro and in vivo studies were conducted. A total of 39 studies were included for data extraction. In the systematic review data, 10 studies stated that zirconia accumulated less initial oral biofilm parameters, 16 investigations showed negligible inter-material differences, and only one study showed that zirconia attracted the most biofilm. However, in the meta-analysis, the bacterial coverage was found to be significantly superior for zirconia surfaces (P< 0.00001); the other outcome measures did not show any statistically significant differences between zirconia and titanium for the remaining parameters and the studies presented a substantial degree of heterogeneity. Overall, on the basis of the meta-analysis, the current data situation does not allow a clear preference for the use of zirconia or titanium.
Collapse
|
5
|
Immediate dental and skeletal influence of distractor position on surgically assisted rapid palatal expansion with or without pterygomaxillary disjunction. Int J Oral Maxillofac Surg 2020; 50:649-656. [PMID: 33131988 DOI: 10.1016/j.ijom.2020.10.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Revised: 08/18/2020] [Accepted: 10/08/2020] [Indexed: 10/23/2022]
Abstract
The outcome of surgically assisted rapid palatal expansion (SARPE) can be affected by pterygomaxillary disjunction (PMD) and the distractor position. In this study, SARPE was performed, with or without PMD, in 20 fresh cadaver heads. Transverse expansion was conducted twice using a bone-borne distractor in the anterior and posterior positions, resulting in four groups (n=10). Cone beam computed tomography scans were completed before and after SARPE to evaluate maxillary changes. A comparative anterior decrease and posterior increase in midpalatal opening resulted from SARPE with PMD combined with a posteriorly placed distractor. Significant differences in the internal transverse changes were found between the two SARPE techniques combined with an anterior distractor at the level of the premolars and molars for alveolar ridge width (P=0.040, P=0.024), and at the level of the molars for the dental crown width (P=0.017) and corresponding tooth cusp width (P=0.018). In contrast, using a posteriorly placed distractor led to a significant difference for tooth cusp width only (P=0.050). No statistically significant differences were found between external transverse changes or between distractor positions. PMD is more important in achieving a more uniform and parallel transverse expansion pattern than the distractor position. However, a posterior distractor seems to intensify the effects of PMD.
Collapse
|
6
|
Evaluation of a novel osteosynthesis plate system for mandibular defects. Br J Oral Maxillofac Surg 2020; 58:e109-e114. [PMID: 32800607 DOI: 10.1016/j.bjoms.2020.07.018] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2020] [Accepted: 07/16/2020] [Indexed: 11/17/2022]
Abstract
Continuity defects of the jaw can be reconstructed with titanium plates or microvascular bone flaps; osteosynthesis plates are necessary for both. In this study we performed a retrospective review of patients treated with Medartis MODUS® Mandible Trauma/Reco 2.0-2.5, TriLock bridging plates, mandibulectomy and soft tissue free flap or reconstruction with a bony free flap and TriLock mandibular plates from the same system from January 2015 to August 2019. The variables recorded were sex, age, diagnosis, radiotherapy, date of implantation, date of explantation or death of patient, size of mandibular defect, Jewer classification of defect, number of screws used, segments of bony reconstruction, screws per segment, plate exposure, plate breakage, and pseudarthrosis. The bridging plate group consisted of 41 patients, while the mandibular plate group consisted of 24 patients. The percentage of plate exposure was 17.07% for the bridging plate group and 4.17% for the mandibular plate group. Plate breakage was 0 in both groups. Pseudarthrosis was 4.17% in the mandibular plate group. In the bridging plate group, an anterolateral thigh flap covered all exposures. Of 7 plate exposures, 4 were found in a C defect. The complication rate of the investigated plates was lower than the complication rates of other plate systems.
Collapse
|
7
|
Influence of bone density, screw size and surgical procedure on orthodontic mini-implant placement - part B: implant stability. Int J Oral Maxillofac Surg 2020; 50:565-572. [PMID: 32713778 DOI: 10.1016/j.ijom.2020.07.003] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2019] [Revised: 04/17/2020] [Accepted: 07/02/2020] [Indexed: 11/19/2022]
Abstract
This in vitro study aimed to investigate the influence of bone density, implant size, and surgical procedure on the primary stability (PS) of orthodontic mini-implants (OMIs). In total, 640 OMIs of various sizes (2.0 × 7, 2.3 × 7, 2.0 × 11 and 2.3 × 11 mm) were inserted in the artificial bone of different densities (D1-D4). Placement was performed with an insertion angle of 90° or 60° to the bone surface and in 320 cases without predrilling, which resulted in 64 groups. PS was measured on the basis of implant stability quotient (ISQ) and insertion torque (IT). With regard to all possible influencing parameters, the mean PS differed between 39.20 and 60.00 (ISQ), and 10.00 and 39.00 Ncm (IT). The effect of OMI size and surgical procedure was dependent on bone quality. For example, implant size had less effect in high-density bone and was stronger with decreasing density. Overall, implant length had a greater influence than the diameter, and a high correlation was found among both PS measurement techniques. Therefore, a suitable choice of implant size and surgical protocol with regard to bone density can positively influence PS. In principle, ISQ and IT are suitable for measuring OMI stability.
Collapse
|
8
|
Influence of bone density, screw size and surgical procedure on orthodontic mini-implant placement - part A: temperature development. Int J Oral Maxillofac Surg 2020; 50:555-564. [PMID: 32694036 DOI: 10.1016/j.ijom.2020.07.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2019] [Revised: 04/17/2020] [Accepted: 07/02/2020] [Indexed: 10/23/2022]
Abstract
The aim of this in vitro study was to determine the influence of bone density, orthodontic mini-implant (OMI) size, and the surgical procedure on temperature increase during implant site osteotomy and placement. OMIs of different sizes (2.0×7, 2.3×7, 2.0×11, and 2.3×11mm) were placed in artificial bone blocks of different densities (D1-D4). Optionally, the drilling and insertion angle was 90° or 60° to the bone surface. A total of 640 OMIs were inserted, and predrilling was performed in 320 cases. All insertions were done without irrigation with an axial load of 20N, which resulted in 64 groups. Temperature measurements were performed during implant site preparation and placement using Type-K-thermocouples. Mean temperature increase differed for OMI osteotomy between 1.38°C and 8.75°C and placement between 3.8°C and 18.74°C, respectively. Critical thermal increase was especially reached during placement using long implants. Increasing bone density and implant size (diameter <length) correlated with thermal increase. Predrilling and angulated implant placement resulted in less heat development. Critical temperature behaviour in high-density bone could be partially responsible for the high failure rates of OMI placement in the lower jaw. The influence of the implant size on temperature development should be considered when selecting an OMI.
Collapse
|
9
|
Aesthetic aspects of adjacent maxillary single-crown implants-influence of zirconia and titanium as implant materials. Int J Oral Maxillofac Surg 2020; 49:1489-1496. [PMID: 32362537 DOI: 10.1016/j.ijom.2020.04.003] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2019] [Revised: 01/30/2020] [Accepted: 04/02/2020] [Indexed: 10/24/2022]
Abstract
The purpose of this retrospective survey was to assess the esthetic aspects of adjacent zirconia and titanium implants in the anterior maxillary area. A total of 40 patients and 109 adjacent implants (17 patients with 47 titanium implants and 23 patients with 62 zirconia implants) was included. The primary aim of this survey was to assess the papillary fill (Jemt score). Additionally, further esthetic aspects were assessed. Papillae were fully present (Jemt score 3) around 39.1% of adjacent zirconia implants and 17.4% of adjacent titanium implants (p<0.01). The papilla deficit was significantly higher 1.64 mm (SD 1.35) around titanium compared to zirconia implants 0.92 mm (SD 0.94, p<0.01). The evaluation of the soft tissue recessions revealed no differences between implant materials, whereas titanium implants presented more visible implant shadows (p<0.01). Zirconia implants had more implants with papillae that filled the entire proximal space compared to titanium implants. Furthermore, titanium implants had a greater frequency of visible implant shadowing than the zirconia implants. Esthetic rules such as the interdental contact area and golden percentage rules did not differ significantly between the titanium and zirconia implants.
Collapse
|
10
|
Evaluation of SPECT/CT in the assessment of inflammatory jaw pathologies. Eur J Radiol 2020; 125:108917. [PMID: 32120276 DOI: 10.1016/j.ejrad.2020.108917] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2019] [Revised: 12/19/2019] [Accepted: 02/21/2020] [Indexed: 11/28/2022]
Abstract
PURPOSE Since accurate diagnosis of inflammatory jaw diseases is still challenging, this study investigated the performance of three phase bone scintigraphy including SPECT/CT in the assessment of correct diagnosis and size of the affected bone tissue. METHOD This retrospective study contained 31 patients with suspected jaw-related osteoradionecrosis, osteomyelitis or medication-related osteonecrosis of the jaw, which underwent 3-phase bone scintigraphy including SPECT/CT. Results were reviewed by two nuclear medicine physicians. Positive cases received surgery; negative ones were followed-up for six months. Both served as reference standard. Inflamed bone length was measured in the SPECT/CT images and postoperatively by a pathologist. RESULTS 19 out of 20 positive cases and 10 out of 11 negative ones were classified correctly by SPECT/CT (sensitivity 95 %, specificity 91 %, accuracy 94 %, positive predictive value 95 %, negative predictive value 91 %). Regarding the length of affected bone, no significant difference (p = 0.23) could be observed between SPECT/CT and postoperative obtained values. Both correlated significantly (r = 0.86, p = 0.0001). CONCLUSION SPECT/CT can safely detect different kinds of inflammatory jaw pathologies compared to other conventional imaging modalities. Lack of specificity of conventional scintigraphy ranging from 17 % to 71 % in earlier studies could be improved by adding CT-analysis. Additionally, SPECT/CT assists the surgeon in determining the expansion of the process (with focus on the length) preoperatively and thereby optimizing surgery planning.
Collapse
|
11
|
Objective computerised assessment of residual ridge resorption in the human maxilla and maxillary sinus pneumatisation. Clin Oral Investig 2020; 24:3223-3235. [PMID: 32095886 DOI: 10.1007/s00784-020-03196-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2019] [Accepted: 01/03/2020] [Indexed: 01/13/2023]
Abstract
OBJECTIVES Atrophic resorption of the maxillary alveolar ridge is a complication that makes implantological rehabilitation critical. Our aim was to develop a novel computer aided procedure for the accurate quantitative assessment of maxillary residual ridge resorption including pneumatisation of the maxillary sinus that goes beyond previously described approaches and to apply it to a large dataset. MATERIALS AND METHODS To develop and refine the method, we performed a retrospective analysis using computed tomography data from 405 patients to generate segmented, three-dimensional models of zygomaticomaxillary bones and maxillary sinuses. Using anatomical landmarks and orientation lines or planes, all models were aligned automatically to subsequently generate cross-sectional images (n = 2835), enabling the classification of atrophy as well as the quantification of volumes and caudal extensions of the maxillary sinuses. RESULTS We developed and implemented an accurate and reproducible workflow for the semi-automated analysis of volumetric maxillary images. Comprehensive statistical analysis of the large quantitative dataset revealed various correlations of maxillary process heights and sinus volumes with atrophy class, age and region and identified conjectural trends over the patient group. CONCLUSIONS The method was used successfully to process a large dataset to classify atrophy, to measure alveolar height parameters, and to quantify maxillary sinus volume, bottom volume and pneumatisation. CLINICAL RELEVANCE Apart from the anthropometric value of the generated dataset, the method could be applied to provide additional and more accurate data to assess the necessity of bone augmentation in the context of three-dimensional planning before implantation.
Collapse
|
12
|
Evaluation of the bactericidal effect of cold atmospheric pressure plasma on contaminated human bone: an in vitro study. Br J Oral Maxillofac Surg 2020; 58:329-333. [PMID: 31969253 DOI: 10.1016/j.bjoms.2020.01.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2019] [Accepted: 01/03/2020] [Indexed: 01/03/2023]
Abstract
The use of cold atmospheric pressure plasma (CAPP) as a bacterial decontaminant for chronic wounds has shown good results. The purpose of this in vitro study was to evaluate the bactericidal effects of CAPP on the cancellous area of the bone. Sterile glass slides and processed sterile human bone allografts 1, 2, 3, and 4mm thick were used for initial contamination and further CAPP treatment. Each block was contaminated with Staphylococcus aureus suspension on one side. Each slide was turned 180° and treated on the reverse side. The bacterial count in colony-forming units (CFU) was then measured and compared with that of a control group, and the bactericidal effects of CAPP in relation to bone density evaluated. A significant reduction in count was measured between treated and untreated groups (groups A-D: p<0.01 and group E: p=0.04). A strong positive linear relation was found between bone density and the S aureus count (r=0.844, p=0.156). Treatment with CAPP had a bactericidal effect on bone structures with a penetration depth of up to 4mm. It might be used for all diseases involving infected bone, and so extends the existing range of treatments.
Collapse
|
13
|
Predicting primary stability of orthodontic mini‐implants, according to position, screw‐size, and bone quality, in the maxilla of aged patients: a cadaveric study. Eur J Oral Sci 2019; 127:462-471. [DOI: 10.1111/eos.12651] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/07/2019] [Indexed: 11/29/2022]
|
14
|
Effects on primary stability of three different techniques for implant site preparation in synthetic bone models of different densities. Br J Oral Maxillofac Surg 2016; 54:980-986. [PMID: 27461557 DOI: 10.1016/j.bjoms.2016.07.004] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2015] [Accepted: 07/05/2016] [Indexed: 10/21/2022]
Abstract
Preparation of implant sites affect the primary stability of implants that is necessary for osseointegration. We have investigated the effect on the primary stability of implants of three techniques used to prepare the site for implants in synthetic bone models of different densities. A total of 540 implants of varying diameters (3.3 (narrow), 4.1 (standard), and 4.8 (wide) mm) and lengths (8 or 12mm) were inserted into three artificial bone blocks (the density of which decreased from D2, D3, to D4), and we compared conventional, fully-guided, and condensing preparation of the site. After insertion, primary stability was measured using resonance frequency analysis. There were significant differences between conventional and condensing procedures (p <0.0001 in all cases) and between fully-guided and condensing procedures (p<0.01 in all cases), but there were no differences between fully-guided and conventional procedures when short implants were used, with a standard or wide diameter in low-density bone blocks (D3 and D4). In low-density bone blocks (D3 and D4) wide implants (4.8mm) compared with narrow (3.3mm) resulted in significantly better primary stability (p<0.0001 in all cases). Fully-guided preparation of the implant site is associated with increased primary stability, but is not an alternative to bone condensing. Use of longer or wider implants can increase primary stability, but the effect is less pronounced after bone condensing.
Collapse
|
15
|
Impairment of an atrophic mandible by preparation of the implant cavity: a biomechanical study. Br J Oral Maxillofac Surg 2016; 54:619-24. [PMID: 27068851 DOI: 10.1016/j.bjoms.2016.03.013] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2015] [Accepted: 03/14/2016] [Indexed: 11/30/2022]
|
16
|
Corrigendum to "Heat generation and drill wear during dental implant site preparation: systematic review" [Br. J. Oral Maxillofac. Surg. 53(8) (2015) 679–689]. Br J Oral Maxillofac Surg 2016; 54:117. [PMID: 27110618 DOI: 10.1016/j.bjoms.2015.11.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
The authors regret D. A. Mitchell’s affiliation address was listed incorrectly in the original paper. The correct affiliation addressis: Maxillofacial Unit, Bradford Teaching Hospitals NHS Foundation Trust, St Lukes, Hospital, Little Horton Lane, Bradford,West Yorkshire, BD5 0NA, England, UK.The authors would like to apologise for any inconvenience caused.
Collapse
|
17
|
Heat generation and drill wear during dental implant site preparation: systematic review. Br J Oral Maxillofac Surg 2015; 53:679-89. [PMID: 26051868 DOI: 10.1016/j.bjoms.2015.05.004] [Citation(s) in RCA: 77] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2014] [Accepted: 05/07/2015] [Indexed: 10/23/2022]
Abstract
To identify factors that minimise damage during the drilling of sites for dental implants, we reviewed published papers on the amount of heat that is generated. We systematically searched English language studies published between January 2000 and February 2014 on MEDLINE/PubMed and found 41 articles, of which 27 related to an increase in temperature during preparation of the site. We found only basic research with a low level of evidence. Most of the studies were in vitro, and osteotomies were usually made in non-vital bone from cows or pigs. To measure heat in real time, thermocouples were used in 18 studies and infrared thermographs in 7. Three studies reported the use of immunohistochemical analysis to investigate immediate viability of cells. The highest temperature measured was 64.4°C and the lowest 28.4°C. Drill wear was reported after preparation of 50 sites, and there was a significant increase in temperature and a small change in the physiological balance of the proteins in the bone cells. Differences in the study designs meant that meta-analysis was not appropriate. For future work, we recommend the use of standard variables: an axial load of 2kg, drilling speed of 1500rpm, irrigation, standard artificial bone blocks, and the use of infrared thermography.
Collapse
|