Kobayashi Frisk L, Verma M, Bešlija F, Lin CHP, Patil N, Chetia S, Trobaugh JW, Culver JP, Durduran T. Comprehensive workflow and its validation for simulating diffuse speckle statistics for optical blood flow measurements. Biomed Opt Express 2024; 15:875-899. [PMID: 38404339 PMCID: PMC10890893 DOI: 10.1364/boe.502421] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Revised: 12/19/2023] [Accepted: 12/20/2023] [Indexed: 02/27/2024]
Abstract
Diffuse optical methods including speckle contrast optical spectroscopy and tomography (SCOS and SCOT), use speckle contrast (κ) to measure deep blood flow. In order to design practical systems, parameters such as signal-to-noise ratio (SNR) and the effects of limited sampling of statistical quantities, should be considered. To that end, we have developed a method for simulating speckle contrast signals including effects of detector noise. The method was validated experimentally, and the simulations were used to study the effects of physical and experimental parameters on the accuracy and precision of κ. These results revealed that systematic detector effects resulted in decreased accuracy and precision of κ in the regime of low detected signals. The method can provide guidelines for the design and usage of SCOS and/or SCOT instruments.
Collapse
Affiliation(s)
- Lisa Kobayashi Frisk
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels (Barcelona), Spain
| | - Manish Verma
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels (Barcelona), Spain
| | - Faruk Bešlija
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels (Barcelona), Spain
| | - Chen-Hao P. Lin
- Department of Physics, Washington University in St. Louis, St. Louis, Missouri 63110, USA
- Department of Radiology, Washington University School of Medicine, St. Louis, Missouri 63110, USA
| | - Nishighanda Patil
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels (Barcelona), Spain
| | - Sumana Chetia
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels (Barcelona), Spain
| | - Jason W. Trobaugh
- Department of Electrical and Systems Engineering, Washington University School of Medicine, St. Louis, Missouri 63110, USA
| | - Joseph P. Culver
- Department of Physics, Washington University in St. Louis, St. Louis, Missouri 63110, USA
- Department of Radiology, Washington University School of Medicine, St. Louis, Missouri 63110, USA
| | - Turgut Durduran
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels (Barcelona), Spain
- Institució Catalana de Recerca i Estudis Avançats (ICREA), Barcelona, Spain
| |
Collapse
|
2
|
Lin CHP, Orukari I, Frisk LK, Verma M, Chetia S, Beslija F, Eggebrecht AT, Durduran T, Culver JP, Trobaugh JW. Anatomical Modeling and Optimization of Speckle Contrast Optical Tomography. bioRxiv 2023:2023.09.06.556565. [PMID: 37732196 PMCID: PMC10508753 DOI: 10.1101/2023.09.06.556565] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/22/2023]
Abstract
Traditional methods for mapping cerebral blood flow (CBF), such as positron emission tomography and magnetic resonance imaging, offer only isolated snapshots of CBF due to scanner logistics. Speckle contrast optical tomography (SCOT) is a promising optical technique for mapping CBF. However, while SCOT has been established in mice, the method has not yet been demonstrated in humans - partly due to a lack of anatomical reconstruction methods and uncertainty over the optimal design parameters. Herein we develop SCOT reconstruction methods that leverage MRI-based anatomical head models and finite-element modeling of the SCOT forward problem (NIRFASTer). We then simulate SCOT for CBF perturbations to evaluate sensitivity of imaging performance to exposure time and SD-distances. We find image resolution comparable to intensity-based diffuse optical tomography at superficial cortical tissue depth (~1.5 cm). Localization errors can be reduced by including longer SD-measurements. With longer exposure times speckle contrast decreases, however, noise decreases faster, resulting in a net increase in SNR. Specifically, extending exposure time from 10μs to 10ms increased SCOT SNR by 1000X. Overall, our modeling methods provide anatomically-based image reconstructions that can be used to evaluate a broad range of tissue conditions, measurement parameters, and noise sources and inform SCOT system design.
Collapse
Affiliation(s)
- Chen-Hao P. Lin
- Department of Physics, Washington University in St. Louis, St. Louis, MO, 63130, USA
- Department of Radiology, Washington University School of Medicine, St. Louis, MO, 63110, USA
| | - Inema Orukari
- Department of Radiology, Washington University School of Medicine, St. Louis, MO, 63110, USA
| | - Lisa Kobayashi Frisk
- ICFO - Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels, Barcelona, Spain
| | - Manish Verma
- ICFO - Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels, Barcelona, Spain
| | - Sumana Chetia
- ICFO - Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels, Barcelona, Spain
| | - Faruk Beslija
- ICFO - Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels, Barcelona, Spain
| | - Adam T. Eggebrecht
- Department of Radiology, Washington University School of Medicine, St. Louis, MO, 63110, USA
| | - Turgut Durduran
- ICFO - Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels, Barcelona, Spain
- Institució Catalana de Recerca i Estudis Avançats (ICREA), Barcelona, Spain
| | - Joseph P. Culver
- Department of Physics, Washington University in St. Louis, St. Louis, MO, 63130, USA
- Department of Radiology, Washington University School of Medicine, St. Louis, MO, 63110, USA
- Department of Electrical and Systems Engineering, Washington University in St. Louis, St. Louis, MO, 63130, USA
| | - Jason W. Trobaugh
- Department of Electrical and Systems Engineering, Washington University in St. Louis, St. Louis, MO, 63130, USA
| |
Collapse
|
3
|
Frisk LK, Verma M, Bešlija F, Lin CHP, Patil N, Chetia S, Trobaugh J, Culver JP, Durduran T. A comprehensive workflow and its validation for simulating diffuse speckle statistics for optical blood flow measurements. bioRxiv 2023:2023.08.03.551830. [PMID: 37577491 PMCID: PMC10418286 DOI: 10.1101/2023.08.03.551830] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/15/2023]
Abstract
Diffuse optical methods including speckle contrast optical spectroscopy and tomography (SCOS and SCOT), use speckle contrast (κ ) to measure deep blood flow. In order to design practical systems, parameters such as signal-to-noise ratio (SNR) and the effects of limited sampling of statistical quantities, should be considered. To that end, we have developed a method for simulating speckle contrast signals including effects of detector noise. The method was validated experimentally, and the simulations were used to study the effects of physical and experimental parameters on the accuracy and precision of κ . These results revealed that systematic detector effects resulted in decreased accuracy and precision of κ in the regime of low detected signals. The method can provide guidelines for the design and usage of SCOS and/or SCOT instruments.
Collapse
Affiliation(s)
- Lisa Kobayashi Frisk
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels (Barcelona), Spain
| | - Manish Verma
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels (Barcelona), Spain
| | - Faruk Bešlija
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels (Barcelona), Spain
| | - Chen-Hao P. Lin
- Department of Physics, Washington University in St. Louis, St. Louis, Missouri 63110, USA
- Department of Radiology, Washington University School of Medicine, St. Louis, Missouri 63110, USA
| | - Nishighanda Patil
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels (Barcelona), Spain
| | - Sumana Chetia
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels (Barcelona), Spain
| | - Jason Trobaugh
- Department of Electrical and Systems Engineering, Washington University School of Medicine, St. Louis, Missouri 63110, USA
| | - Joseph P. Culver
- Department of Physics, Washington University in St. Louis, St. Louis, Missouri 63110, USA
- Department of Radiology, Washington University School of Medicine, St. Louis, Missouri 63110, USA
| | - Turgut Durduran
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels (Barcelona), Spain
- Institució Catalana de Recerca i Estudis Avançats (ICREA), Barcelona, Spain
| |
Collapse
|
4
|
Lin CHP, Orukari I, Tracy C, Frisk LK, Verma M, Chetia S, Durduran T, Trobaugh JW, Culver JP. Multi-mode fiber-based speckle contrast optical spectroscopy: analysis of speckle statistics. Opt Lett 2023; 48:1427-1430. [PMID: 36946944 DOI: 10.1364/ol.478956] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Accepted: 02/03/2023] [Indexed: 06/18/2023]
Abstract
Speckle contrast optical spectroscopy/tomography (SCOS/T) provides a real-time, non-invasive, and cost-efficient optical imaging approach to mapping of cerebral blood flow. By measuring many speckles (n>>10), SCOS/T has an increased signal-to-noise ratio relative to diffuse correlation spectroscopy, which measures one or a few speckles. However, the current free-space SCOS/T designs are not ideal for large field-of-view imaging in humans because the curved head contour cannot be readily imaged with a single flat sensor and hair obstructs optical access. Herein, we evaluate the feasibility of using cost-efficient multi-mode fiber (MMF) bundles for use in SCOS/T systems. One challenge with speckle contrast measurements is the potential for confounding noise sources (e.g., shot noise, readout noise) which contribute to the standard deviation measure and corrupt the speckle contrast measure that is central to the SCOS/T systems. However, for true speckle measurements, the histogram of pixel intensities from light interference follows a non-Gaussian distribution, specifically a gamma distribution with non-zero skew, whereas most noise sources have pixel intensity distributions that are Gaussian. By evaluating speckle data from static and dynamic targets imaged through an MMF, we use histograms and statistical analysis of pixel histograms to evaluate whether the statistical properties of the speckles are retained. We show that flow-based speckle can be distinguished from static speckle and from sources of system noise through measures of skew in the pixel intensity histograms. Finally, we illustrate in humans that MMF bundles relay blood flow information.
Collapse
|
5
|
Paul R, Murali K, Chetia S, Varma HM. A simple algorithm for diffuse optical tomography without Jacobian inversion. Biomed Phys Eng Express 2022; 8. [PMID: 35447616 DOI: 10.1088/2057-1976/ac6909] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2022] [Accepted: 04/21/2022] [Indexed: 11/11/2022]
Abstract
A computationally simpler algorithm to reconstruct the optical property distribution of turbid media using diffuse optical tomographic principles is presented. The proposed algorithm eliminates the requirement of large Jacobian matrix inversion which otherwise is essential for tomographic imaging. The most significant Jacobians are identified based on proper thresholding of the measurement and the intersection of these Jacobians gives the approximate spatial location of the inhomogeneity. The algorithm is tested and optimized using simulations and further validated using tissue-mimicking phantom-based experiments andin-vivosmall-animal experiments.
Collapse
Affiliation(s)
- Ria Paul
- Indian Institute of Technology Bombay (IITB), Mumbai-400076, India
| | - K Murali
- Indian Institute of Technology Bombay (IITB), Mumbai-400076, India
| | - Sumana Chetia
- Indian Institute of Technology Bombay (IITB), Mumbai-400076, India
| | - Hari M Varma
- Indian Institute of Technology Bombay (IITB), Mumbai-400076, India
| |
Collapse
|