1
|
Masuda T, Kiguchi M, Fujioka C, Oku T, Ishibashi T, Katsunuma Y, Yoshitake T, Abe S, Awai K. Impact of beam collimation of z-overscanning on dose to the lens and thyroid gland in paediatric thoracic computed tomography imaging. Pediatr Radiol 2024; 54:758-763. [PMID: 38308740 DOI: 10.1007/s00247-024-05862-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 01/17/2024] [Accepted: 01/19/2024] [Indexed: 02/05/2024]
Abstract
BACKGROUND Adaptive collimation reduces the dose deposited outside the imaged volume along the z-axis. An increase in the dose deposited outside the imaged volume (to the lens and thyroid) in the z-axis direction is a concern in paediatric computed tomography (CT). OBJECTIVE To compare the dose deposited outside the imaged volume (to the lens and thyroid) between 40-mm and 80-mm collimation during thoracic paediatric helical CT. MATERIALS AND METHODS We used anthropomorphic phantoms of newborns and 5-year-olds with 40-mm and 80-mm collimation during helical CT. We compared the measured dose deposited outside the imaged volume using optically stimulated luminescence dosimeters (OSLD) at the surfaces of the lens and thyroid and the image noise between the 40-mm and 80-mm collimations. RESULTS There were significant differences in the dose deposited outside the imaged volume (to the lens and thyroid) between the 40-mm and 80-mm collimations for both phantoms (P < 0.01). CONCLUSION Compared with that observed for 80-mm collimation in helical CT scans of the paediatric thorax, the dose deposited outside the imaged volume (to the lens and thyroid) was significantly lower in newborns and 5-year-olds with 40-mm collimation.
Collapse
Affiliation(s)
- Takanori Masuda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Matsushima, Kurashiki, Okayama, 288701-0193, Japan.
| | - Masao Kiguchi
- Department of Radiology, Hiroshima University, Hiroshima, Japan
| | - Chikako Fujioka
- Department of Radiology, Hiroshima University, Hiroshima, Japan
| | - Takayuki Oku
- Department of Radiological Technologist, Tsuchiya General Hospital, Hiroshima, Japan
| | - Toru Ishibashi
- Department of Radiological Technologist, Tsuchiya General Hospital, Hiroshima, Japan
| | - Yasushi Katsunuma
- Department of Radiological Technology, Tokai University Oiso Hospital, Kanagawa, Japan
| | | | - Shuji Abe
- Department of Radiological Technology, Osaka College of High Technology, Osaka, Japan
| | - Kazuo Awai
- Department of Diagnostic Radiology, Hiroshima University, Hiroshima, Japan
| |
Collapse
|
2
|
Masuda T, Nakaura T, Higaki T, Funama Y, Matsumoto Y, Sato T, Okimoto T, Arao K, Imaizumi H, Arao S, Ono A, Hiratsuka J, Awai K. Using Patient-Specific Contrast Enhancement Optimizer Simulation Software During the Transcatheter Aortic Valve Implantation-Computed Tomography Angiography in Patients With Aortic Stenosis. J Comput Assist Tomogr 2024:00004728-990000000-00300. [PMID: 38595080 DOI: 10.1097/rct.0000000000001603] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/11/2024]
Abstract
OBJECTIVES This study assessed whether patient-specific contrast enhancement optimizer simulation software (p-COP) can reduce the contrast material (CM) dose compared with the conventional body weight (BW)-tailored scan protocol during transcatheter aortic valve implantation-computed tomography angiography (TAVI-CTA) in patients with aortic stenosis. METHODS We used the CM injection protocol selected by the p-COP in group A (n = 30). p-COP uses an algorithm that concerns data on an individual patient's cardiac output. Group B (n = 30) was assigned to the conventional BW-tailored CM injection protocol group. We compared the CM dose, CM amount, injection rate, and computed tomography (CT) values in the abdominal aorta between the 2 groups and classified them as acceptable (>280 Hounsfield units (HU)) or unacceptable (<279 HU) based on the optimal CT value and visualization scores for TAVI-CTA. We used the Mann-Whitney U test to compare patient characteristics and assess the interpatient variability of subjects in both groups. RESULTS Group A received 56.2 mL CM and 2.6 mL/s of injection, whereas group B received 76.9 mL CM and 3.4 mL/s of injection (P < 0.01). The CT value for the abdominal aorta at the celiac level was 287.0 HU in group A and 301.7HU in group B (P = 0.46). The acceptable (>280 HU) and unacceptable (<280 HU) CT value rates were 22 and 8 patients in group A and 24 and 6 patients in group B, respectively (P = 0.76). We observed no significant differences in the visualization scores between groups A and B (visualization score = 3, P = 0.71). CONCLUSION The utilization of p-COP may decrease the CM dosage and injection rate by approximately 30% in individuals with aortic stenosis compared with the body-weight-tailored scan protocol during TAVI-CTA.
Collapse
Affiliation(s)
- Takanori Masuda
- From the Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Kurashiki City, Okayama, Japan
| | - Takeshi Nakaura
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, Kumamoto, Japan
| | - Toru Higaki
- Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima, Japan
| | - Yoshinori Funama
- Department of Medical Physics, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japan
| | - Yoriaki Matsumoto
- Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima, Japan
| | - Tomoyasu Sato
- Department of Diagnostic Radiology, Tsuchiya General Hospital, Naka-ku, Hiroshima, Japan
| | - Tomokazu Okimoto
- Department of Cardiovascular Internal Medicine, Edogawa Hospital, Tokyo, Japan
| | - Keiko Arao
- From the Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Kurashiki City, Okayama, Japan
| | - Hiromasa Imaizumi
- From the Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Kurashiki City, Okayama, Japan
| | - Shinichi Arao
- From the Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Kurashiki City, Okayama, Japan
| | - Atsushi Ono
- From the Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Kurashiki City, Okayama, Japan
| | - Junichi Hiratsuka
- From the Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Kurashiki City, Okayama, Japan
| | - Kazuo Awai
- Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima, Japan
| |
Collapse
|
3
|
Yoshiura T, Masuda T, Tahara M, Kobayashi Y, Kikuhara Y, Ishibashi T, Nonaka H, Oku T, Sato T, Funama Y. Cardiac computed tomography angiography with and without bolus tracking methods in infants with congenital heart disease. Radiat Prot Dosimetry 2024; 200:251-258. [PMID: 38088430 DOI: 10.1093/rpd/ncad295] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 10/12/2023] [Accepted: 11/15/2023] [Indexed: 03/05/2024]
Abstract
The study investigated radiation dose, vascular computed tomography (CT) enhancement and image quality of cardiac computed tomography angiography (CCTA) with and without bolus tracking (BT) methods in infants with congenital heart disease (CHD). The volume CT dose index (CTDIvol) and dose length product (DLP) were recorded for all CT scans, and the effective dose was obtained using a conversion factors. The CT number for the ascending aorta (AO) and pulmonary artery (PA), image noise of muscle tissue and contrast-to-noise ratio (CNR) were measured and calculated. The median values in the groups with and without BT were 2.20 mGy versus 0.44 mGy for CTDIvol, 8.10 mGy·cm versus 6.20 mGy·cm for DLP, and 0.66 mSv versus 0.51 mSv for effective dose (p < 0.001). There were no statistical differences in vascular CT enhancement, image noise, and CNR. CCTA without BT methods can reduce the radiation dose while maintaining vascular CT enhancement and image quality compared to CCTA with BT methods.
Collapse
Affiliation(s)
- Takayuki Yoshiura
- Graduate School of Health Sciences, Kumamoto University, 4-24-1 Kuhonji, Kumamoto, 862-0976, Japan
- Department of Medical Technology, Tsuchiya General Hospital, 3-30 Nakajima-cho, Hiroshima, 730-8655, Japan
| | - Takanori Masuda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki-City, Okayama, 701-0193, Japan
| | - Masahiro Tahara
- Hiroshima Central Street Children's Clinic, 7-1 Mikawa-cho, Hiroshima, 730-0029, Japan
| | - Yukie Kobayashi
- Department of Medical Technology, Tsuchiya General Hospital, 3-30 Nakajima-cho, Hiroshima, 730-8655, Japan
| | - Yukari Kikuhara
- Department of Medical Technology, Tsuchiya General Hospital, 3-30 Nakajima-cho, Hiroshima, 730-8655, Japan
| | - Toru Ishibashi
- Department of Medical Technology, Tsuchiya General Hospital, 3-30 Nakajima-cho, Hiroshima, 730-8655, Japan
| | - Haruki Nonaka
- Department of Medical Technology, Tsuchiya General Hospital, 3-30 Nakajima-cho, Hiroshima, 730-8655, Japan
| | - Takayuki Oku
- Department of Medical Technology, Tsuchiya General Hospital, 3-30 Nakajima-cho, Hiroshima, 730-8655, Japan
| | - Tomoyasu Sato
- Department of Medical Technology, Tsuchiya General Hospital, 3-30 Nakajima-cho, Hiroshima, 730-8655, Japan
| | - Yoshinori Funama
- Department of Medical Radiation Sciences, Faculty of Life Sciences, Kumamoto University, 4-24-1 Kuhonji, Kumamoto, 862-0976, Japan
| |
Collapse
|
4
|
Masuda T, Takei Y, Arao S. Is the use of gonad protection protectors necessary during infants chest radiography? Radiologia (Engl Ed) 2024; 66:107-113. [PMID: 38614527 DOI: 10.1016/j.rxeng.2022.08.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Accepted: 08/21/2022] [Indexed: 04/15/2024]
Abstract
INTRODUCTION AND OBJECTIVES To compare gonad doses with and without a gonad protector and to optimize the use of gonadal protectors in infants thorax radiography. MATERIALS AND METHODS Two pediatric anthropomorphic phantoms are used: an X-ray system for KXO-50SS/DRX-3724HD, and a digital radiography system for CALNEO Smart C12, with and without a gonad protector during infants thorax radiography. A real time skin dosimeter is placed on the X-ray system, and a real time skin dosimeter is inserted on the front side of the mammary gland, the front and back sides of the true pelvis level, and on the ovaries and testes. The X-ray system is irradiated 15 times using phantoms with and without a gonad protector. The measured entrance patient doses values of for the real time skin dosimeter are compared for each phantom, with and without the gonad protector. RESULTS The medium of measured entrance patient doses values for front side dose of the true pelvis level with and without the protector are 10.00 and 5.00 μGy at newborn, and 10.00 and 0.00μGy at one year, respectively. The medium of measured entrance patient doses values for the back side dose of the true pelvis level with and without the protector are 0.00 and 0.00 μGy at both newborn one year, respectively. The measured entrance patient doses cannot be detected in the ovaries and testes with or without the protector. No significant differences are observed in the measured entrance patient doses values for the front and back side doses of the pelvis, ovaries, and testes at newborn and one year, with and without the protector (p>0.05). CONCLUSIONS No significant difference was observed in gonad dose measurements with and without the gonad protector during infants chest radiography. We believe that gonadal protector wearing is not necessary.
Collapse
Affiliation(s)
- T Masuda
- Departamento de Tecnología Radiológica, Facultad de Ciencia y Tecnología de la Salud, Universidad de Bienestar Médico de Kawasaki, Kurashiki, Okayama, Japan.
| | - Y Takei
- Departamento de Tecnología Radiológica, Facultad de Ciencia y Tecnología de la Salud, Universidad de Bienestar Médico de Kawasaki, Kurashiki, Okayama, Japan
| | - S Arao
- Departamento de Tecnología Radiológica, Facultad de Ciencia y Tecnología de la Salud, Universidad de Bienestar Médico de Kawasaki, Kurashiki, Okayama, Japan
| |
Collapse
|
5
|
Ikenaga H, Masuda T, Ishikawa T, Tani T, Moriwake R, Yao D. [Investigation of the Correlation between Patient Characteristics and Contrast Enhancement during Hepatic Dynamic CT Scan: Comparison by the Sex]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2024; 80:199-206. [PMID: 38104981 DOI: 10.6009/jjrt.2024-1263] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2023]
Abstract
The purpose of this study was to investigate the correlation between patient characteristics and contrast enhancement during the hepatic arterial phase (HAP) and portal venous phase (PVP) CT scanning. All were examined using a hepatic dynamic CT protocol; the scanning parameters were tube voltage 120 kVp, tube current 50 to 600 mA (noise index 8.0 HU), 0.5-s rotation, 5-mm detector row width, 0.813 or 0.825 beam pitch, and the contrast material 600 mg/kg iodine. We calculated contrast enhancement (per gram of iodine: ΔHU/gI) of the abdominal aorta during the HAP and that of the hepatic parenchyma during the PVP. There was a significant difference in the contrast enhancement of the abdominal aorta during the HAP (8.6±2.7 ΔHU/gI) and (9.5±1.7 ΔHU/gI) and that of the hepatic parenchyma during the PVP (1.4±0.5 ΔHU/gI) and (2.9±0.5 ΔHU/gI) between male and female patients (p<0.05). A significant positive correlation was seen between the ΔHU/gI of aortic enhancement and age in male and female patients (r=-0.382 and 0.213) (p<0.05). A significant inverse correlation was observed between the ΔHU/gI of aortic enhancement and the height (HT; r=-0.466 and -0.251), total body weight (TBW; r=-0.609 and -0.535), body mass index (BMI; r=-0.505 and -0.465), lean body weight (LBW; r=-0.642 and -0.576), and body surface area (BSA; r=-0.644 and -0.557) (p<0.05 for all) in male and female patients. A significant positive correlation was seen between the ΔHU/gI of hepatic parenchymal enhancement and the patient age in male and female patients (r=0.258 and 0.150) (p<0.05). A significant inverse correlation was observed between the ΔHU/gI of hepatic parenchymal enhancement and the HT (r=-0.487 and -0.321), TBW (r=-0.580 and -0.525), BMI (r=-0.473 and -0.413), LBW (r=-0.615 and -0.576) (p<0.05 for all), and BSA (r=-0.617 and -0.558) in male and female patients. The BSA was significantly correlated with the ΔHU/gI of aortic and hepatic parenchymal enhancement of the hepatic dynamic CT in male patients. However, LBW was significantly correlated with the ΔHU/gI of aortic and hepatic parenchymal enhancement of the hepatic dynamic CT in female patients. Since the patient factors that affect the contrast enhancement of the abdominal aorta and hepatic parenchyma may differ from facility to facility, we should therefore consider reassessing at each facility.
Collapse
Affiliation(s)
| | - Takanori Masuda
- Faculty of Health Science and Technology, Kawasaki University of Medical Welfare
| | | | - Tadashi Tani
- Department of Radiology, Kawasaki Medical School Hospital
| | - Ryo Moriwake
- Department of Radiology, Kawasaki Medical School Hospital
| | - Daiki Yao
- Department of Radiology, Kawasaki Medical School Hospital
| |
Collapse
|
6
|
Masuda T, Kiguchi M, Fujioka C, Oku T, Ishibashi T, Katsunuma Y, Yoshitake T, Abe S, Awai K. Effectiveness of low tube voltage scan in the exposure dose for lenses during paediatric thoracic CT examination: anthropomorphic phantoms study. Radiat Prot Dosimetry 2024; 200:143-148. [PMID: 37987195 DOI: 10.1093/rpd/ncad284] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/09/2023] [Revised: 10/04/2023] [Accepted: 10/30/2023] [Indexed: 11/22/2023]
Abstract
To determine whether using lower-tube voltage reduces the scattered dose for the lens during paediatric thoracic computed tomography (CT). Two paediatric anthropomorphic phantoms (ATOM Phantom, CIRS, Norfolk, Virginia, USA) representing a newborn and 5-year-old were placed on the gantry of CT scanner, and optically stimulated luminescence dosemeters were placed on the left and right lenses, in front of the left and right thyroid glands, in front of the left and right mammary glands, and in front of and behind the mammary gland level and we measured scattered dose of the optically stimulated luminescence dosemeter was compared for each phantom between 80 and 120 kVp. Significant differences were observed in the scatter doses for the lens between 80 and 120 kVp (p < 0.01). Compared with the 120 kVp scan, the scatter doses for the lens were ~15-40% lower in newborn and 5-year-olds using the 80 kVp scan during paediatric CT.
Collapse
Affiliation(s)
- Takanori Masuda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama 701-0193, Japan
| | - Masao Kiguchi
- Department of Radiology, Hiroshima University, 2-3, Kasumi, Minami-ku, Hiroshima 734-0037, Japan
| | - Chikako Fujioka
- Department of Radiology, Hiroshima University, 2-3, Kasumi, Minami-ku, Hiroshima 734-0037, Japan
| | - Takayuki Oku
- Department of Radiological Technologist, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - Toru Ishibashi
- Department of Radiological Technologist, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - Yasushi Katsunuma
- Department of Radiological Technology, Tokai University Oiso Hospital, 143, Shimokasuya, Iseharashi, Kanagawa 259-1193, Japan
| | - Takayasu Yoshitake
- TOWCAR WORKS Co., Ltd Hoashi 233-1, Kusu-machi, Kusugun, Oita 879-4403, Japan
| | - Shuji Abe
- Department of Radiological Technologist, Osaka College of High Technology, 1-2-43, Miyahara, Yogogawa-ku, Osaka 532-0003, Japan
| | - Kazuo Awai
- Department of Diagnostic Radiology, Hiroshima University, 2-3, Kasumi, Minami-ku, Hiroshima 734-0037, Japan
| |
Collapse
|
7
|
Kobayashi N, Masuda T, Nakaura T, Shiraishi K, Uetani H, Nagayama Y, Kidoh M, Funama Y, Hirai T. The Feasibility of Using a Deep Learning-Based Model to Determine Cardiac Computed Tomographic Contrast Dose. J Comput Assist Tomogr 2024; 48:85-91. [PMID: 37531644 DOI: 10.1097/rct.0000000000001532] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/04/2023]
Abstract
PURPOSE This study aimed to predict contrast effects in cardiac computed tomography (CT) from CT localizer radiographs using a deep learning (DL) model and to compare the prediction performance of the DL model with that of conventional models based on patients' physical size. METHODS This retrospective study included 473 (256 men and 217 women) cardiac CT scans between May 2014 and August 2017. We developed and evaluated DL models that predict milligrams of iodine per enhancement of the aorta from CT localizer radiographs. To assess the model performance, we calculated and compared Pearson correlation coefficient ( r ) between the actual iodine dose that was necessary to obtain a contrast effect of 1 HU (iodine dose per contrast effect [IDCE]) and IDCE predicted by DL, body weight, lean body weight, and body surface area of patients. RESULTS The model was tested on 52 cases for the male group (mean [SD] age, 63.7 ± 11.4) and 44 cases for the female group (mean [SD] age, 69.8 ± 11.6). Correlation coefficients between the actual and predicted IDCE were 0.607 for the male group and 0.412 for the female group, which were higher than the correlation coefficients between the actual IDCE and body weight (0.539 for male, 0.290 for female), lean body weight (0.563 for male, 0.352 for female), and body surface area (0.587 for male, 0.349 for female). CONCLUSIONS The performance for predicting contrast effects by analyzing CT localizer radiographs with the DL model was at least comparable with conventional methods using the patient's body size, notwithstanding that no additional measurements other than CT localizer radiographs were required.
Collapse
Affiliation(s)
- Naoki Kobayashi
- From the Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University1, Kumamoto
| | - Takanori Masuda
- Department of Radiological Technology, Tsuchiya General Hospital, Hiroshima
| | - Takeshi Nakaura
- From the Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University1, Kumamoto
| | - Kaori Shiraishi
- From the Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University1, Kumamoto
| | - Hiroyuki Uetani
- From the Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University1, Kumamoto
| | - Yasunori Nagayama
- From the Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University1, Kumamoto
| | - Masafumi Kidoh
- From the Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University1, Kumamoto
| | | | - Toshinori Hirai
- From the Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University1, Kumamoto
| |
Collapse
|
8
|
Ikenaga H, Masuda T, Yamamoto A, Moriwake R, Yoshida K, Ishikawa T, Yao D, Ono A, Hiratsuka J, Tamada T. Influence of splenomegaly on aortic and liver parenchymal CT numbers during contrast-enhance CT in patients with cirrhosis. Radiography (Lond) 2024; 30:382-387. [PMID: 38150883 DOI: 10.1016/j.radi.2023.12.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2023] [Revised: 12/05/2023] [Accepted: 12/10/2023] [Indexed: 12/29/2023]
Abstract
INTRODUCTION To compare CT (computed tomography) values for enhancement of the abdominal aorta and liver parenchyma during dynamic contrast enhancement (CE) CT in cirrhotic patients with and without splenomegaly (SM). METHODS We considered 258 patients (83 males and 46 females for the splenomegaly group, and 83 males and 46 females for the control group) for this retrospective study. We measured CT values in the abdominal aorta and hepatic parenchyma during the hepatic arterial (HAP) and portal venous (PVP) phases. The aortic CE at HAP and the hepatic parenchymal CE at PVP were compared between the two groups. For success rate of scans, we also calculated the optimal CE rates (>280 HU in the abdominal aorta and >50 HU in the hepatic parenchyma) for each group. RESULTS In the SM group, the CE for abdominal aorta was decreased during the aortic phase for a dynamic CE-CT (p < 0.05). When evaluating the success rates, they were found to be 65.1 % and 58.9 % in the SM group and 81.4 % and 72.3 % in the non-SM group (p < 0.05). CONCLUSION The success rate of scans and CE for the abdominal aorta during the aortic phase exhibited a significant decrease during dynamic CE-CT scans on patients with SM. Patients with SM may have reduced diagnostic ability with typical contrast injection protocols. IMPLICATIONS FOR PRACTICE It may be necessary to change the injection rates and contrast medium volume during CE-CT depending on the presence or absence of SM.
Collapse
Affiliation(s)
- H Ikenaga
- Department of Radiological Technology, Kawasaki Medical School Hospital, 577, Matsushima, Kurashiki-city, Okayama, 701-0192, Japan
| | - T Masuda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan.
| | - A Yamamoto
- Department of Radiology, Kawasaki Medical School, 577, Matsushima, Kurashiki-city, Okayama, 701-0192, Japan
| | - R Moriwake
- Department of Radiological Technology, Kawasaki Medical School Hospital, 577, Matsushima, Kurashiki-city, Okayama, 701-0192, Japan
| | - K Yoshida
- Department of Radiological Technology, Kawasaki Medical School Hospital, 577, Matsushima, Kurashiki-city, Okayama, 701-0192, Japan
| | - T Ishikawa
- Department of Radiological Technology, Kawasaki Medical School Hospital, 577, Matsushima, Kurashiki-city, Okayama, 701-0192, Japan
| | - D Yao
- Department of Radiological Technology, Kawasaki Medical School Hospital, 577, Matsushima, Kurashiki-city, Okayama, 701-0192, Japan
| | - A Ono
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan
| | - J Hiratsuka
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan
| | - T Tamada
- Department of Radiology, Kawasaki Medical School, 577, Matsushima, Kurashiki-city, Okayama, 701-0192, Japan
| |
Collapse
|
9
|
Yoshiura T, Masuda T, Kobayashi Y, Kikuhara Y, Ishibashi T, Nonaka H, Oku T, Sato T, Funama Y. Iodine contrast volume reduction in preoperative transcatheter aortic valve implantation computed tomography: Comparison with 64- and 256-multidetector row computed tomography. Radiography (Lond) 2024; 30:408-415. [PMID: 38176131 DOI: 10.1016/j.radi.2023.12.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Revised: 12/24/2023] [Accepted: 12/25/2023] [Indexed: 01/06/2024]
Abstract
INTRODUCTION This study aimed to compare the vascular enhancement and radiation dose in preoperative transcatheter aortic valve implantation (TAVI) computed tomography (CT) with a reduced contrast medium (CM) using volume scans in 256-multidetector row CT (MDCT) with a standard CM using 64-MDCT. METHODS This study included 78 patients with preoperative TAVI CT with either 64- or 256-MDCT. The CM was injected at 1.5 mL/kg in the 64-MDCT group and 1.0 mL/kg in the 256-MDCT group. We compared vascular enhancement of the aortic root and access routes, image quality (IQ) scores, and radiation dose in both groups. RESULTS Despite the reduced CM (by 33 %) in the 256-MDCT group, the mean vascular enhancement of the right and left subclavian arteries was significantly higher than that in the 64-MDCT group [284 and 267 Hounsfield units (HU) vs. 376 and 359 HU; p < 0.05]; however, no significant differences in the mean vascular enhancement in the ascending aorta, abdominal aorta at the celiac level, and bilateral common femoral arteries were observed between the two groups (p > 0.05 for all). The median IQ scores at the aortic root were higher in the 256-MDCT group than in the 64-MDCT group (3 vs. 4; p < 0.05), and those at the femoral access routes were comparable (4 vs. 4; p = 0.33). The mean effective dose was significantly reduced by 30 % in the 256-MDCT group (23.6 vs. 16.3 mSv; p < 0.05). CONCLUSION In preoperative TAVI CT, volume scans using 256-MDCT provide comparable or better vascular enhancement and IQ with a 30 % reduction in CM and radiation dose than those using 64-MDCT. IMPLICATIONS FOR PRACTICE Volume scan using 256-MDCT for preoperative TAVI CT may reduce CM and radiation dose in TAVI patients with renal dysfunction.
Collapse
Affiliation(s)
- T Yoshiura
- Graduate School of Health Sciences, Kumamoto University, Kuhonji 4-24-1, Chuo-ku, Kumamoto, 860-0976, Japan; Department of Medical Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima, 730-8655, Japan.
| | - T Masuda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Matsushima 288, Okayama, 701-0193, Japan.
| | - Y Kobayashi
- Department of Medical Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima, 730-8655, Japan.
| | - Y Kikuhara
- Department of Medical Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima, 730-8655, Japan.
| | - T Ishibashi
- Department of Medical Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima, 730-8655, Japan.
| | - H Nonaka
- Department of Medical Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima, 730-8655, Japan.
| | - T Oku
- Department of Medical Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima, 730-8655, Japan.
| | - T Sato
- Department of Medical Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima, 730-8655, Japan.
| | - Y Funama
- Department of Medical Radiation Sciences, Faculty of Life Sciences, Kumamoto University, Honjo 1-1-1, Chuo-ku, Kumamoto, 860-8556, Japan.
| |
Collapse
|
10
|
Nishiyama N, Masuda T, Nakagawa J, Terami K, Nakaura T. Optimization of wrist tendon detection in virtual monochromatic images using dual energy-computed tomography. Jpn J Radiol 2023; 41:1397-1404. [PMID: 37460747 DOI: 10.1007/s11604-023-01467-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Accepted: 07/05/2023] [Indexed: 12/01/2023]
Abstract
OBJECTIVES To evaluate the depiction of wrist tendons in virtual monochromatic images (VMIs) during a dual-energy CT (DE-CT) with the VMI image of conventional equivalent to 120 kVp. MATERIALS AND METHODS Using Catphan600 and phantom analysis software for CT evaluation, measurements of VMI in a DE-CT were performed corresponding to the tube voltages of single-energy CT at 120 kVp. Using a Discovery CT750 HD CT scanner (GE Healthcare) with DE-CT technology, 73 patients were scanned. We calculated the CT number, image noise, visual score, and contrast noise ratio (CNR) at the extensor pollicis tendon, extensor digitorum tendon, and flexor tendon in 11 VMIs from the DE-CT and VMI image of conventional equivalent to 120 kVp. The results from the optimal VMIs were then compared with that of the VMI image of the conventional equivalent to 120 kVp. RESULTS The highest CT number and CNR for the tendon were for the 140 keV VMI in the DE-CT compared to the other energy levels. There were significantly higher CT numbers, CNR values, and visual scores for each tendon at 140 keV VMI with the DE-CT (p < 0.01) compared with a VMI image of conventional equivalent to 120 kVp. CONCLUSION Energy level of the VMIs during DE-CT for the best wrist tendon delineation was 140 keV. This value of 140 keV for the DE-CT was significantly higher than the CT number and CNR for the extensor pollicis, extensor digitorum, and flexor tendon compared with a VMI image of conventional equivalent to 120 kVp.
Collapse
Affiliation(s)
- Norimi Nishiyama
- Department of Radiological Technologist, Okayama Saiseikai General Hospital, 2-25, Kokutai-cho, Kita-ku, Okayama-shi, Okayama, 700-8511, Japan
| | - Takanori Masuda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki, Okayama, 701-0193, Japan.
| | - Junnichi Nakagawa
- Department of Radiological Technologist, Okayama Saiseikai General Hospital, 2-25, Kokutai-cho, Kita-ku, Okayama-shi, Okayama, 700-8511, Japan
| | - Keisuke Terami
- Department of Radiological Technologist, Okayama Saiseikai General Hospital, 2-25, Kokutai-cho, Kita-ku, Okayama-shi, Okayama, 700-8511, Japan
| | - Takeshi Nakaura
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto, 860-8556, Japan
| |
Collapse
|
11
|
Arao S, Masuda T, Oku T, Ono A, Okura Y. Utility of lower tube voltage scans in reducing exposure of healthcare workers within computed tomography room to scattered radiation. Radiat Prot Dosimetry 2023; 199:2338-2343. [PMID: 37646071 DOI: 10.1093/rpd/ncad240] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Revised: 07/25/2023] [Accepted: 08/11/2023] [Indexed: 09/01/2023]
Abstract
The aim of this study was to estimate the effect of tube voltage on the scattered dose in a computed tomography (CT) room. To this end, we conducted experiments using anthropomorphic phantoms and a CT scanner at different tube voltages during CT. The scattered dose was measured using an electronic pocket dosemeter at 50-cm intervals from the centre of the gantry. The structure of the CT room was measured at 57 points (28 points in the front of the gantry (on the bed side), 6 points on the side of the gantry and 23 points behind the gantry) to be up to 200 cm. We compared the scattered dose distributions between 80 and 120 kVp at heights of 50, 100 and 150 cm above the floor surface. The scattered dose was reduced by ~30% when the tube voltage was reduced from 120 to 80 kVp.
Collapse
Affiliation(s)
- Shinichi Arao
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki, Okayama 701-0193, Japan
| | - Takanori Masuda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki, Okayama 701-0193, Japan
| | - Takayuki Oku
- Department of Diagnostic Radiology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima, Hiroshima 730-8655, Japan
| | - Atsushi Ono
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki, Okayama 701-0193, Japan
| | - Yasuhiko Okura
- Department of Clinical Radiology, Faculty of Health Sciences, Hiroshima International University, 555-36 Kurosegakuendai, Higashihiroshima, Hiroshima 739-2695, Japan
| |
Collapse
|
12
|
Masuda T, Funama Y, Nakaura T, Sato T, Oku T, Gotanda R, Arao K, Imaizumi H, Arao S, Ono A, Hiratsuka J, Awai K. Usefulness of electrocardiogram mA modulation during the electrocardiogram-gated CT scan in paediatrics with high heart rate for different helical pitch: a phantom-based assessment study. Radiat Prot Dosimetry 2023:ncad180. [PMID: 37337642 DOI: 10.1093/rpd/ncad180] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/08/2023] [Revised: 04/08/2023] [Accepted: 05/29/2023] [Indexed: 06/21/2023]
Abstract
We investigated the effect of electrocardiographic (ECG) mA-modulation of ECG-gated scans of computed tomography (CTA) on radiation dose and image noise at high heart rates (HR) above 100 bpm between helical pitches (HP) 0.16 and 0.24. ECG mA-modulation range during ECG-gated CTA is 50-100 mA, the phase setting is 40-60% and the scan range is 90 mm for clinical data during HR for 90, 120 and 150 bpm. Radiation dose and image noise in Housfield units are measured for CT equipment during HR for 90, 120 and 150 bpm between HP 0.16 and 0.24. ECG mA-modulation, dose reduction ratio for HR 90, 120 and 150 bpm are 19.1, 13.4 and 8.7% at HP 0.16 and 17.1, 13.3 and 7.7% at HP 0.24, respectively. No significant differences were observed in image noise between both HP. Dose reductions of 8-24% are achieved with ECG mA-modulation during ECG-gated CCTA scan, which is beneficial even in high HR more than 100 bpm.
Collapse
Affiliation(s)
- Takanori Masuda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki City 701-0193 Japan
| | - Yoshinori Funama
- Department of Medical Physics, Faculty of Life Sciences, Kumamoto University, Kumamoto 860-8555, Japan
| | - Takeshi Nakaura
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto 860-8556, Japan
| | - Tomoyasu Sato
- Department of Diagnostic Radiology, Tsuchiya General Hospital, Nakajima-cho 3-30, Hiroshima 730-8655, Japan
| | - Takayuki Oku
- Department of Radiological Technologist, Tsuchiya General Hospital, Nakajima-cho 3-30, Hiroshima 730-8655, Japan
| | - Rumi Gotanda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki City 701-0193 Japan
| | - Keiko Arao
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki City 701-0193 Japan
| | - Hiromasa Imaizumi
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki City 701-0193 Japan
| | - Shinichi Arao
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki City 701-0193 Japan
| | - Atsushi Ono
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki City 701-0193 Japan
| | - Junichi Hiratsuka
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki City 701-0193 Japan
| | - Kazuo Awai
- Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima 739-0046, Japan
| |
Collapse
|
13
|
Uemura T, Takabe Y, Okazaki H, Matsumura N, Masuda T, Hoshikawa Y. Influences of changing inorganic nitrogen concentration on accumulation and degradation of organic components in indigenous microalgae cultivated with secondary effluent. Environ Technol 2023; 44:2462-2472. [PMID: 35080483 DOI: 10.1080/09593330.2022.2034977] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/11/2020] [Accepted: 01/20/2022] [Indexed: 06/08/2023]
Abstract
Climatic changes due to emission of greenhouse gases are a global concern. These emissions occur by combustion of fossil fuels whose drought is near in which case renewable energy is the only alternative. Microalgae are promising sources of sustainable bioenergy production, and utilisation of wastewater as cultures is recommended for economical production cost. In this study, indigenous microalgae, which had adaptability for wastewater samples, were cultivated with a municipal secondary effluent, and influences of changes in inorganic nitrogen (IN) concentration, specifically IN increase, on temporal accumulation and degradation of organic components in indigenous microalgae were investigated. Indigenous microalgae accumulated total lipids and carbohydrates against reduced IN, and increase in superoxide dismutase suggested that the accumulation was possibly induced by generating reactive oxygen species. Continued cultivation of indigenous microalgae under the IN exhausted condition should be avoided because of the resulting total carbohydrate degradation. IN replenishment when IN was decreased but still existed in the culture and that when IN was exhausted in the culture triggered sharp degradation of the total carbohydrate, which possibly utilised to accumulate crude protein and/or chlorophyll a for continuous growth or regrowth. The total carbohydrate was accumulated and recovered after the degradation; meanwhile, two or three days were required for the recovery of the total carbohydrate. In addition, the IN replenishment also resulted in total lipid degradation. Therefore, to produce indigenous microalgae with high and stable total carbohydrate and lipid content, it was critical to prevent IN increase in the culture.
Collapse
Affiliation(s)
- Takumi Uemura
- Graduate School of Engineering, Tottori University, Tottori, Japan
| | - Yugo Takabe
- Graduate School of Engineering, Tottori University, Tottori, Japan
| | - Hironori Okazaki
- Graduate School of Engineering, Tottori University, Tottori, Japan
| | | | - Takanori Masuda
- Graduate School of Engineering, Tottori University, Tottori, Japan
| | | |
Collapse
|
14
|
Ishibashi T, Takei Y, Kato M, Yamashita Y, Tsukamoto A, Matsumoto K, Sakamoto H, Masuda T, Miyazaki O. Patient dosimetry survey of pediatric diagnostic and therapeutic cardiac catheterisation in Japan. Radiat Prot Dosimetry 2023:7135728. [PMID: 37092251 DOI: 10.1093/rpd/ncad139] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Revised: 11/28/2022] [Accepted: 02/27/2023] [Indexed: 05/03/2023]
Abstract
To propose reference values for air-kerma at the reference point (Ka,r), air-kerma area product (PKA), fluoroscopy time (FT) and number of cine images (CI) for four age groups in Japan, a nationwide questionnaire was posted to 132 pediatric catheterisation of certified facility in Japan, using the conventional post system, to which 43 facilities responded. For diagnostic cardiac angiography, reference values were as follows: Ka,r: 86, 102, 165 and 264 mGy; PKA: 9.3, 9.5, 16 and 34 Gy.cm2; FT: 33, 29, 26 and 30 min and CI: 1904, 1966, 2405 and 1871 images. For therapeutic cardiac angiography, reference values were as follows: Ka,r: 107, 163, 103 and 202 mGy; PKA: 7.5, 18, 7 and 24 Gy.cm2; FT: 56, 52, 42 and 30 min and CI: 3886, 3232, 2212 and 4316 images for less than 1, 1-5, 6-10 and 11-15 y, respectively. To optimal patient exposure from diagnostic and therapeutic cardiac catheterisation, it is therefore necessary to establish reference values for pediatric cardiac catheterisation examinations for four age groups.
Collapse
Affiliation(s)
- Toru Ishibashi
- Department of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - Yasutaka Takei
- Department of Radiological Technology, Faculty of Health Science and Technology, School of Health Sciences, Ishikawa 920-0942, Japan
| | - Mamoru Kato
- Department of Radiology and Nuclear Medicine, Akita Cerebrospinal and Cardiovascular Center, Akita 010-0874, Japan
| | - Yukari Yamashita
- Department of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - Atsuko Tsukamoto
- Department of Radiology, NTT Medical Center Tokyo, Tokyo 141-8625, Japan
| | - Kazuma Matsumoto
- Department of Clinical Radiology, Hyogo College of Medicine College Hospital, Hyogo 663-8131, Japan
| | - Hajime Sakamoto
- Department of Radiological Technology, Faculty of Health Science, Juntendo University, Tokyo 113-8421, Japan
| | - Takanori Masuda
- Department of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - Osamu Miyazaki
- Department of Radiology, National Center for Child Health and Development, Tokyo 157-1535, Japan
| |
Collapse
|
15
|
Masuda T, Nakaura T, Funama Y, Sato T, Masuda S, Gotanda R, Arao K, Imaizumi H, Arao S, Ono A, Hiratsuka J, Awai K. RADIATION DOSE REDUCTION AT LOW TUBE VOLTAGE WITH CORONARY ARTERY BYPASS GRAFT COMPUTED TOMOGRAPHY ANGIOGRAPHY BASED ON THE CONTRAST NOISE RATIO INDEX. Radiat Prot Dosimetry 2023; 199:527-532. [PMID: 36881907 DOI: 10.1093/rpd/ncad049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Revised: 02/08/2023] [Accepted: 02/10/2023] [Indexed: 06/18/2023]
Abstract
To compare the radiation dose and diagnostic ability of the 100-kVp protocol, based on the contrast noise ratio (CNR) index, during coronary artery bypass graft (CABG) vessels with those of the 120-kVp protocol. For the 120-kVp scans (150 patients), the targeted image level was set at 25 Hounsfield units (HU) (CNR120 = iodine contrast/25 HU). For the 100-kVp scans (150 patients), the targeted noise level was set at 30 HU to obtain the same CNR as in the 120-kVp scans (i.e. using 1.2-fold higher iodine contrast, CNR100 = 1.2 × iodine contrast/(1.2 × 25 HU) = CNR120). We compared the CNRs, radiation doses, detection of CABG vessels and visualisation scores of the scans acquired at 120 and 100 kVp, respectively. At the same CNR, the 100-kVp protocol may help reduce the radiation dose by ⁓30% compared with the 120-kVp protocol, without degradation of diagnostic ability during CABG.
Collapse
Affiliation(s)
- Takanori Masuda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama 701-0193, Japan
| | - Takeshi Nakaura
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto 860-8556, Japan
| | - Yoshinori Funama
- Department of Medical Physics, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japan
| | - Tomoyasu Sato
- Department of Diagnostic Radiology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - Shouko Masuda
- Department of Radiological Technology, Kawamura clinic Otemachi, Naka-ku, Hiroshima 730-0051, Japan
| | - Rumi Gotanda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama 701-0193, Japan
| | - Keiko Arao
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama 701-0193, Japan
| | - Hiromasa Imaizumi
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama 701-0193, Japan
| | - Shinichi Arao
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama 701-0193, Japan
| | - Atsushi Ono
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama 701-0193, Japan
| | - Junichi Hiratsuka
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama 701-0193, Japan
| | - Kazuo Awai
- Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima, Japan
| |
Collapse
|
16
|
Masuda T, Nakaura T, Funama Y, Sato T, Masuda S, Yoshiura T, Gotanda R, Arao K, Imaizumi H, Arao S, Ono A, Hiratsuka J, Awai K. Effect of patient characteristics on vessel enhancement on arterio-venous fistula CT angiography in a retrospective cohort study. Medicine (Baltimore) 2023; 102:e33328. [PMID: 36961162 PMCID: PMC10036065 DOI: 10.1097/md.0000000000033328] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/05/2021] [Accepted: 02/28/2023] [Indexed: 03/25/2023] Open
Abstract
To evaluate the effects of various patient characteristics on vessel enhancement on arterio-venous fistula (AVF) computed tomography (CT) angiography (AVF-CT angiography). A total of 127 patients with suspected or confirmed shunt stenosis and internal AVF complications were considered for inclusion in a retrospective cohort study. The tube voltage was 120 kVp, and the tube current was changed from 300 to 770 mA to maintain the image quality (noise index: 14) using automatic tube current modulation. To evaluate the effects of age, sex, body size, and scan delay on the CT number of the brachial artery or vein, we used correlation coefficients and multivariate regression analyses. There was a significant positive correlation between the CT number of the brachial artery or vein and age (R = 0.21 or 0.23, P < .01). The correlations were inverse with the height (r = -0.45 or -0.42), total body weight (r = -0.52 or -0.50), body mass index (r = -0.21 or -0.23), body surface area (body surface area [BSA]; r = -0.56 or -0.54), and lean body weight (r = -0.55 or -0.53) in linear regression analysis (P < .01 for all). There was a significant correlation between the CT number of the brachial artery or vein and scan delay (R = 0.19 or 01.9, P < .01). Only the BSA had significant effects on the CT number in multivariate regression analysis (P < .01). The BSA was significantly correlated with the CT number of the brachial artery or vein on AVF-CT angiography.
Collapse
Affiliation(s)
- Takanori Masuda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Kurashiki, Okayama, Japan
| | - Takeshi Nakaura
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, Kumamoto, Japan
| | - Yoshinori Funama
- Department of Medical Physics, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japan
| | - Tomoyasu Sato
- Department of Diagnostic Radiology, Tsuchiya General Hospital, Naka-ku, Hiroshima, Japan
| | - Shouko Masuda
- Department of Radiological Technologist, Kawamura Clinic, Hiroshima, Japan
| | - Takayuki Yoshiura
- Department of Radiological Technology, Tsuchiya General Hospital, Naka-ku, Hiroshima, Japan
| | - Rumi Gotanda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Kurashiki, Okayama, Japan
| | - Keiko Arao
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Kurashiki, Okayama, Japan
| | - Hiromasa Imaizumi
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Kurashiki, Okayama, Japan
| | - Shinichi Arao
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Kurashiki, Okayama, Japan
| | - Atsushi Ono
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Kurashiki, Okayama, Japan
| | - Junichi Hiratsuka
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Kurashiki, Okayama, Japan
| | - Kazuo Awai
- Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima, Japan
| |
Collapse
|
17
|
Moriwake R, Masuda T, Yamamoto A, Ikenaga H, Yoshida K, Takei Y, Yao D, Ono A, Hiratsuka J, Tamada T. COMPARISON OF THE 64- AND 80-DETECTOR ROW COMPUTED TOMOGRAPHY AMONG THE CT NUMBER AND RADIATION DOSE DURING LOWER EXTREMITY COMPUTED TOMOGRAPHY ANGIOGRAPHY. Radiat Prot Dosimetry 2023; 199:356-362. [PMID: 36609697 DOI: 10.1093/rpd/ncac277] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/05/2022] [Revised: 11/12/2022] [Accepted: 11/28/2022] [Indexed: 06/17/2023]
Abstract
To compare the computed tomography (CT) number and the radiation dose between the 64 (group A) and 80-detector row (group B) during lower extremity computed tomography angiography (LE-CTA). We enrolled 144 patients underwent LE-CTA and compared the CT number for the popliteal arteries, radiation dose and the rate of the optimal CT number during the LE-CTA exceeding 200 HU between the two groups. The CT number for the popliteal arteries and mean dose-length product was significantly higher in Group A than in Group B (P < 0.01). The rate of the optimal CT number for the popliteal arteries was 23.6% with Group B scanner and 56.9% with Group A (P < 0.05). The 64-detector row CT was significantly higher in the CT number for the popliteal arteries, radiation dose and rate of the optimal CT number during the LE-CTA than the 80-detector row. Depiction ability did not improve by using a high CT scanner with a wider detector during LE-CTA.
Collapse
Affiliation(s)
- Ryo Moriwake
- Department of Radiological Technology, Kawasaki Medical School Hospital, 577, Matsushima, Kurashiki, Okayama 701-0192, Japan
| | - Takanori Masuda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama 701-0193, Japan
| | - Akira Yamamoto
- Department of Radiology, Kawasaki Medical School, 577, Matsushima, Kurashiki, Okayama 701-0192, Japan
| | - Hiroyuki Ikenaga
- Department of Radiological Technology, Kawasaki Medical School Hospital, 577, Matsushima, Kurashiki, Okayama 701-0192, Japan
| | - Koji Yoshida
- Department of Radiological Technology, Kawasaki Medical School Hospital, 577, Matsushima, Kurashiki, Okayama 701-0192, Japan
| | - Yasutaka Takei
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama 701-0193, Japan
| | - Daiki Yao
- Department of Radiological Technology, Kawasaki Medical School Hospital, 577, Matsushima, Kurashiki, Okayama 701-0192, Japan
| | - Atsushi Ono
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama 701-0193, Japan
| | - Junichi Hiratsuka
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama 701-0193, Japan
| | - Tsutomu Tamada
- Department of Radiology, Kawasaki Medical School, 577, Matsushima, Kurashiki, Okayama 701-0192, Japan
| |
Collapse
|
18
|
Masuda T, Nakaura T, Funama Y, Sato T, Nagayama Y, Kidoh M, Yoshida M, Arao S, Ono A, Hiratsuka J, Hirai T, Awai K. Can Machine Learning Identify the Intravenous Contrast Dose and Injection Rate Needed for Optimal Enhancement on Dynamic Liver Computed Tomography? J Comput Assist Tomogr 2023; Publish Ahead of Print:00004728-990000000-00168. [PMID: 37380150 DOI: 10.1097/rct.0000000000001468] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/30/2023]
Abstract
OBJECTIVES This study aimed to investigate whether machine learning (ML) is useful for predicting the contrast material (CM) dose required to obtain a clinically optimal contrast enhancement in hepatic dynamic computed tomography (CT). METHODS We trained and evaluated ensemble ML regressors to predict the CM doses needed for optimal enhancement in hepatic dynamic CT using 236 patients for a training data set and 94 patients for a test data set. After the ML training, we randomly divided using the ML-based (n = 100) and the body weight (BW)-based protocols (n = 100) by the prospective trial. The BW protocol was performed using routine protocol (600 mg/kg of iodine) by the prospective trial. The CT numbers of the abdominal aorta and hepatic parenchyma, CM dose, and injection rate were compared between each protocol using the paired t test. Equivalence tests were performed with equivalent margins of 100 and 20 Hounsfield units for the aorta and liver, respectively. RESULTS The CM dose and injection rate for the ML and BW protocols were 112.3 mL and 3.7 mL/s, and 118.0 mL and 3.9 mL/s (P < 0.05). There were no significant differences in the CT numbers of the abdominal aorta and hepatic parenchyma between the 2 protocols (P = 0.20 and 0.45). The 95% confidence interval for the difference in the CT number of the abdominal aorta and hepatic parenchyma between 2 protocols was within the range of predetermined equivalence margins. CONCLUSIONS Machine learning is useful for predicting the CM dose and injection rate required to obtain the optimal clinical contrast enhancement for hepatic dynamic CT without reducing the CT number of the abdominal aorta and hepatic parenchyma.
Collapse
Affiliation(s)
- Takanori Masuda
- From the Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Okayama
| | - Takeshi Nakaura
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University
| | - Yoshinori Funama
- Department of Medical Physics, Faculty of Life Sciences, Kumamoto University, Kumamoto
| | - Tomoyasu Sato
- Department of Diagnostic Radiology, Tsuchiya General Hospital
| | - Yasunori Nagayama
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University
| | - Masafumi Kidoh
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University
| | - Masato Yoshida
- Department of Diagnostic Radiology, Tsuchiya General Hospital
| | - Shinichi Arao
- From the Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Okayama
| | - Atsushi Ono
- From the Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Okayama
| | - Junichi Hiratsuka
- From the Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Okayama
| | - Toshinori Hirai
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University
| | - Kazuo Awai
- Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima, Japan
| |
Collapse
|
19
|
Noda N, Masuda T, Yoshiura T, Sato T, Funama Y. [Comparison of Lower Extremity Computed Tomography Angiography by Using Different Subtraction Techniques]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2023; 79:440-445. [PMID: 36878532 DOI: 10.6009/jjrt.2023-1211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/08/2023]
Abstract
PURPOSE To compare the diagnostic capabilities of orbital synchronized helical scanning at lower extremity computed tomography angiography between the Add/Sub software and the deformable image registration. METHODS From March 2015 to December 2016, 100 dialysis patients underwent orbital synchronized lower limb CT subtraction angiography and lower limb endovascular treatment within 4 months. For the visual evaluation of blood vessels in the lower extremities, a stenosis rate of 50% or more was considered to be stenosis. It was classified into two areas: above-knee (AK) region (superficial femoral artery and popliteal artery) and below-knee (BK) region (anterior tibial artery, posterior tibial artery, and fibula artery). Considering angiography for the lower limb endovascular treatment as the golden standard, we calculated the sensitivity, specificity, positive-predictive value, negative-predictive value, and diagnostic capabilities. Receiver operating characteristic curve (ROC) analysis was performed to calculate the area under curve (AUC). RESULTS Calcification subtraction failure was observed to be 11% in the AK region and 2% in the BK region using the Add/Sub software. The specificity, positive-predictive value, diagnostic capabilities, and AUC of the deformable image registration were lower than those of the Add/Sub software. CONCLUSIONS Add/Sub software and deformable image registration have high diagnostic capability to remove calcification. On the other hand, the specificity and AUC of the deformable image registration were lower than those of the Add/Sub software. Also, even if the same deformable image registration is used, caution is required because the diagnostic performance varies depending on the site.
Collapse
Affiliation(s)
| | - Takanori Masuda
- Department of Radiological Technology, Faculty of Medical Science and Technology, Kawasaki University of Medical Welfare
| | | | | | - Yoshinori Funama
- Department of Medical Radiation Sciences, Faculty of Life Sciences, Kumamoto University
| |
Collapse
|
20
|
Masuda T, Funama Y, Nakaura T, Sato T, Urayama K, Kiguchi M, Oku T, Yoshida M, Arao S, Ono A, Hiratsuka J, Awai K. Usefulness of large beam-shaping filters at different tube voltages of newborn chest CT. Phys Eng Sci Med 2023; 46:289-293. [PMID: 36633769 DOI: 10.1007/s13246-023-01217-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 11/10/2022] [Accepted: 01/03/2023] [Indexed: 01/13/2023]
Abstract
BACKGROUND To investigate optimizing the use of different beam shaping filters (viz. small, medium and large) when using different tube voltages during the newborn chest computed tomography (CT) on a GE Lightspeed VCT scanner. METHODS We used pediatric anthropomorphic phantoms with a 64 detector-row CT scanner while scanning the chest. A real-time skin dosimeter (RD - 1000; Trek Corporation, Kanagawa, Japan) was positioned into the phantom center of the body, the surface of the body back, and the right and left mammary glands. We performed and compared six scan protocols using small, medium, and large beam shaping filters at 80 and 120 kVp protocols. RESULT There were no significant differences in the image noise for the chest scan among the different beam shaping filters. By using the large beam shaping filter at 80 kVp, it was possible to reduce the exposure dose by 5% in comparison with the small beam shaping filter, and by 10% in comparison with the medium beam shaping filter. By using the large beam shaping filter at 120 kVp, it was possible to reduce the exposure dose by 15% in comparison with the small beam shaping filter and by 20% in comparison with the medium beam shaping filter (p < 0.01). CONCLUSION The large beam shaping filter had the most dose reduction effect during newborn chest CT on a GE Lightspeed VCT scanner. The additional copper filtration being present in the large bowtie filter of the GE Lightspeed CT scanner when using different tube voltages is more effective in reducing radiation exposure in children.
Collapse
Affiliation(s)
- Takanori Masuda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, 701-0193, Kurashiki-city, Okayama, Japan.
| | - Yoshinori Funama
- Department of Medical Physics, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjo, 860-8556, Kumamoto, Japan
| | - Takeshi Nakaura
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, 860-8556, Kumamoto, Japan
| | - Tomoyasu Sato
- Department of Diagnostic Radiology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, 730-8655, Hiroshima, Japan
| | - Kotaro Urayama
- Department of Pediatric cardiology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, 730-8655, Hiroshima, Japan
| | - Masao Kiguchi
- Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Kasumi 1-2-3 Minami-ku, 734-8551, Hiroshima, Japan
| | - Takayuki Oku
- Department of Radiological technologist, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, 730-8655, Hiroshima, Japan
| | - Masato Yoshida
- Department of Radiological technologist, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, 730-8655, Hiroshima, Japan
| | - Shinichi Arao
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, 701-0193, Kurashiki-city, Okayama, Japan
| | - Atsushi Ono
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, 701-0193, Kurashiki-city, Okayama, Japan
| | - Junichi Hiratsuka
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, 701-0193, Kurashiki-city, Okayama, Japan
| | - Kazuo Awai
- Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Kasumi 1-2-3 Minami-ku, 734-8551, Hiroshima, Japan
| |
Collapse
|
21
|
Matsumoto H, Takei Y, Matsuda E, Masuda T. [Measurement of the Lens Dose for Radiological Technologists during Mobile Radiography]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2023; 79:38-45. [PMID: 36418072 DOI: 10.6009/jjrt.2023-1295] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
The radiological technologists often assist patients near the X-ray area during mobile radiography. Therefore, it is expected that the lens of eye of radiological technologists is exposed to much radiation. The purposes of this study were to measure the lens dose received by radiological technologists during mobile radiography using radiation protection goggles with a personal dosimeter and a small optically stimulated luminescence dosimeter and discuss the need for radiation protection goggles and additional radiation protection measures. From October 2017 to March 2018, lens doses were measured for eight radiological technologists during mobile radiography using radiation protection goggles with a small optically stimulated luminescence dosimeter and a personal dosimeter. The maximum value of the lens dose received by radiological technologists in mobile radiography was 0.3 mSv per month with a personal dosimeter attached to the neck. The dose-reduction effect of radiation protection glasses during mobile radiography was about 45%. The radiation protection goggles are effective for reducing radiation exposure of lens of eye during mobile radiography. Since there is concern about an increase in lens dose, it is desirable to use the radiation protection goggles for reducing the lens of eye exposure.
Collapse
Affiliation(s)
- Hiroki Matsumoto
- Department of Radiological Technology, Kawasaki Medical School Hospital
| | - Yasutaka Takei
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare
| | - Eiji Matsuda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare
| | - Takanori Masuda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare
| |
Collapse
|
22
|
Masuda T, Takei Y, Arao S. ¿Es necesario utilizar protectores de gónadas durante la realización de radiografías de tórax en los lactantes? Radiología 2022. [DOI: 10.1016/j.rx.2022.08.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
23
|
Masuda T, Funama Y, Nakaura T, Sato T, Urayama K, Kiguchi M, Oku T, Arao S, Ono A, Hiratsuka J, Awai K. COMPARISON OF PEDIATRIC LENS DOSE MEASUREMENTS BETWEEN AXIAL SCAN MODE WITHOUT ACTIVE COLLIMATOR AND HELICAL SCAN MODE WITH ACTIVE COLLIMATOR BY USING A 64 DETECTOR-ROW COMPUTED TOMOGRAPHY SCANNER. Radiat Prot Dosimetry 2022; 198:1522-1527. [PMID: 36193882 DOI: 10.1093/rpd/ncac196] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Revised: 08/11/2022] [Accepted: 09/06/2022] [Indexed: 06/16/2023]
Abstract
To investigate the pediatric eye lens entrance surface dose for both axial scan modes without an active collimator and helical scan modes with an active collimator on 64 detector-row computed tomography (CT) scanner. We used three pediatric anthropomorphic phantoms with axial and helical scan modes from the superior orbitomeatal line to the crown of the head. We compared the measured dose values of the real-time skin dosemeter at the surfaces of the lens and the image noise at different scan modes. The median measured dose values for the lens of newborn, 1-year-old and the 5-year-old phantom were 31.3, 0.97 and 0.65 mGy, respectively, in the axial scan mode and 0.89, 1.21 and 0.71 mGy, respectively, in the helical scan mode. Compared with helical scans with an active collimators, axial scans can reduce the lens dose by ∼10% during head CT on 64 detector-row CT scanner without deterioration of image noise.
Collapse
Affiliation(s)
- Takanori Masuda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama 701-0193, Japan
| | - Yoshinori Funama
- Department of Medical Physics, Faculty of Life Sciences, Kumamoto University, Kumamoto, 1-1-1 Honjo, Kumamoto 860-8556, Japan
| | - Takeshi Nakaura
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto 860-8556, Japan
| | - Tomoyasu Sato
- Department of Diagnostic Radiology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - Kotaro Urayama
- Department of Pediatric Cardiology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - Masao Kiguchi
- Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Kasumi 1-2-3 Minami-ku, Hiroshima 734-8551, Japan
| | - Takayuki Oku
- Department of Radiological Technologist, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - Shinichi Arao
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama 701-0193, Japan
| | - Atsushi Ono
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama 701-0193, Japan
| | - Junichi Hiratsuka
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama 701-0193, Japan
| | - Kazuo Awai
- Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Kasumi 1-2-3 Minami-ku, Hiroshima 734-8551, Japan
| |
Collapse
|
24
|
Sato Y, Fujiwara S, Hata A, Kida Y, Masuda T, Amimoto H, Matsumoto H, Miyoshi K, Otsuka K, Tomii K. 1545P A multicenter prospective observational study of pre-existing autoantibodies in patients with small cell lung cancer treated with ICI. Ann Oncol 2022. [DOI: 10.1016/j.annonc.2022.07.1639] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022] Open
|
25
|
Hazama D, Uemura T, Kenmotsu H, Meano K, Wakuda K, Teraoka S, Kobe H, Azuma K, Yamaguchi T, Masuda T, Yokoyama T, Otsubo K, Haratani K, Hayakawa D, Oki M, Takemoto S, Ozaki T, Okabe T, Hata A, Hashimoto H, Yamamoto N, Nakagawa K. EP16.02-005 Liquid Biopsy Detects Genomic Drivers in Non-small Cell Lung Cancer without EGFR Mutations by Single-plex Testing: WJOG13620L. J Thorac Oncol 2022. [DOI: 10.1016/j.jtho.2022.07.1036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
26
|
Oka M, Kurose K, Sakaeda K, Fukuda M, Sakai Y, Atarashi Y, Shimizu K, Masuda T, Nakatomi K, Kawase S, Suetsugu T, Mizuno K, Takemoto S, Yamaguchi H, Inoue H, Hattori N, Nakata M, Mukae H, Oga T. EP08.01-064 Serum NY-ESO-1 and XAGE1 Antibodies Predict and Monitor Clinical Responses to Immune Checkpoint Therapy for NSCLC. J Thorac Oncol 2022. [DOI: 10.1016/j.jtho.2022.07.636] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
27
|
Yoshiura T, Masuda T, Sato T, Kikuhara Y, Kobayashi Y, Ishibashi T, Oku T, Yoshida M, Funama Y. [Coronary Artery Visualization by Using the 64-row MDCT in Pediatric Patients]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2022; 78:856-863. [PMID: 35858799 DOI: 10.6009/jjrt.2022-1194] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
PURPOSE We retrospectively evaluated the visualization of pediatric coronary computed tomography angiography (CCTA) images by using the 64-detector row CT scanner between the electrocardiogram-gated helical scan and non-electrocardiogram-gated helical scan. METHODS From January 2015 to March 2019, 100 children who underwent CT angiography examination were retrospectively enrolled. Group A consisted of 50 patients with electrocardiogram-gated helical scan. Group B consisted of 50 patients with non-electrocardiogram-gated helical scan. All patients were scanned using a 64-detector row CT scanner (LightSpeed VCT), and helical scans were acquired. The CT scanning parameters were 0.4-s rotation, 0.625-mm slice thickness, 0.24 (group A) helical pitch (beam pitch), 1.375 (group B) helical pitch (beam pitch), 80 kVp, and 50-300 mA (noise index 40). A retrospective method was used for electrocardiogram gated. To compare the radiation dose, CT volume dose index (CTDIvol) and dose length product (DLP) displayed on the console were recorded. The visualization scores of the coronary artery images were compared between each group. RESULTS In group A, CTDIvol and DLP values were 6.74 (1.05-11.97) mGy and 79.87 (15.90-146.65) mGy·cm, respectively. In group B, CTDIvol and DLP values were 0.51 (0.39-0.95) mGy and 8.15 (6.30-17.50) mGy·cm, respectively. There were significant differences in CTDIvol and DLP values between both groups (p<0.05). The visualization rates for the proximal and distal coronary arteries were 88% and 54% for the right coronary artery, 84% and 58% for the left anterior descending artery, and 66% and 30% for the left circumflex branch in group A, respectively. The visualization rates for the proximal and distal coronary arteries were 52% and 0% for the right coronary artery, 56% and 0% for the left anterior descending artery, and 32% and 0% for the left circumflex branch in group B. CONCLUSION In 64-row multidetector computed tomography (MDCT), the visualization rates for the proximal and distal coronary arteries were significantly higher in the electrocardiogram-gated scan, but the exposure dose was several times higher in the pediatric CCTA. For accurate diagnosis in pediatric coronary arteries, electrocardiogram-gated helical scan should be performed.
Collapse
Affiliation(s)
- Takayuki Yoshiura
- Department of Medical Technology, Tsuchiya General Hospital
- Graduate School of Health Sciences, Kumamoto University
| | - Takanori Masuda
- Department of Medical Technology, Tsuchiya General Hospital (Current address: Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare)
| | - Tomoyasu Sato
- Department of Medical Technology, Tsuchiya General Hospital
| | | | | | | | - Takayuki Oku
- Department of Medical Technology, Tsuchiya General Hospital
| | - Masato Yoshida
- Department of Medical Technology, Tsuchiya General Hospital
| | - Yoshinori Funama
- Department of Medical Physics, Faculty of Life Sciences, Kumamoto University
| |
Collapse
|
28
|
Masuda T, Nakaura T, Funama Y, Oda S, Okimoto T, Sato T, Noda N, Yoshiura T, Baba Y, Arao S, Hiratsuka J, Awai K. Corrigendum to “Deep learning with convolutional neural network for estimation of the characterisation of coronary plaques: Validation using IB-IVUS” [Radiography 28 (2022) 61–67]. Radiography (Lond) 2022; 28:661-662. [DOI: 10.1016/j.radi.2022.05.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
29
|
Masuda T, Baba Y, Nakaura T, Funama Y, Sato T, Masuda S, Gotanda R, Arao K, Imaizumi H, Arao S, Ono A, Hiratsuka J, Awai K. Applying patient characteristics, stent-graft selection, and pre-operative computed tomographic angiography data to a machine learning algorithm: Is endoleak prediction possible? Radiography (Lond) 2022; 28:906-911. [PMID: 35785641 DOI: 10.1016/j.radi.2022.06.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Revised: 05/28/2022] [Accepted: 06/06/2022] [Indexed: 10/31/2022]
Abstract
INTRODUCTION This study aims to predict endoleak after endovascular aneurysm repair (EVAR) using machine learning (ML) integration of patient characteristics, stent-graft configuration, and a selection of vessel lengths, diameters and angles measured using pre-operative computed tomography angiography (CTA). METHODS We evaluated 1-year follow-up CT scans (arterial and delayed phases) in patients who underwent EVAR for the presence or absence of an endoleak. We also obtained data on the patient characteristics, stent-graft selection, and preoperative CT vessel morphology (diameter, length, and angle). The extreme gradient boosting (XGBoost) for the ML system was trained on 30 patients with endoleaks and 81 patients without. We evaluated 5217 items in 111 patients with abdominal aortic aneurysms, including the patient characteristics, stent-graft configuration and vascular morphology acquired using pre-EVAR abdominal CTA. We calculated the area under the curve (AUC) of our receiver operating characteristic analysis using the ML method. RESULTS The AUC, accuracy, 95% confidence interval (CI), sensitivity, and specificity were 0.88, 0.88, 0.79-0.97, 0.85, and 0.91 for ML applying XGBoost, respectively. CONCLUSIONS The diagnostic performance of the ML method was useful when factors such as the patient characteristics, stent-graft configuration and vessel length, diameter and angle of the vessels were considered from pre-EVAR CTA. IMPLICATIONS FOR PRACTICE Based on our findings, we suggest that this is a potential application of ML for the interpretation of abdominal CTA scans in patients with abdominal aortic aneurysms scheduled for EVAR.
Collapse
Affiliation(s)
- T Masuda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan.
| | - Y Baba
- Department of Diagnostic Radiology, Saitama Medical University International Medical Center, 1397-1, Yamane, Hidaka-City, Saitama-Pref 350-1298, Japan
| | - T Nakaura
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto 860-8556, Japan
| | - Y Funama
- Department of Medical Physics, Faculty of Life Sciences, Kumamoto University, Kumamoto, 1-1-1 Honjo, Kumamoto 860-8556, Japan
| | - T Sato
- Department of Diagnostic Radiology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - S Masuda
- Department of Radiological Technology, Kawamura Clinic, Otemachi, Naka-ku, Hiroshima 730-0051, Japan
| | - R Gotanda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan
| | - K Arao
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan
| | - H Imaizumi
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan
| | - S Arao
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan
| | - A Ono
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan
| | - J Hiratsuka
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan
| | - K Awai
- Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Kasumi 1-2-3 Minami-ku, Hiroshima 734-8551, Japan
| |
Collapse
|
30
|
Miyoshi T, Simazaki D, Tokuyasu M, Masuda T, Akiba M. Metal leaching test of commercially available faucets in the Japanese market in 2016-2020. J Water Health 2022; 20:1112-1125. [PMID: 35902993 DOI: 10.2166/wh.2022.080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
In this study, metal leaching was investigated in commercially available faucets in Japan to clarify their compliance to Japanese regulations. We purchased 37 faucets from the market and analyzed the leaching of cadmium, mercury, selenium, lead (Pb), arsenic, hexavalent chromium, boron, zinc (Zn), copper, manganese, and nickel. The leaching tests were performed with and without a conditioning treatment, that simulated approximately 1-month intermittent use of faucets on weekdays, and the results were compared to estimate the changes in metal leaching during the use of faucets. The results revealed that metal leaching from most of the faucets complied with Japanese regulations. However, the levels of Pb leaching from several faucets produced by certain manufacturers exceeded the Japanese standard. The conditioning treatment was generally effective in reducing metal leaching. However, the reductions in Pb and Zn leaching tended to be lower than those of the other metals. Nickel is not legally regulated in Japan; although the number of cases where nickel concentration in leachate exceeded the water quality management target value was greater, such cases were limited to faucets primarily made of copper alloys. We believe that these results will be helpful to improve the public health associated with metal leaching from faucets.
Collapse
Affiliation(s)
- Taro Miyoshi
- Department of Environmental Health, National Institute of Public Health, Saitama, Japan E-mail:
| | - Dai Simazaki
- Department of Environmental Health, National Institute of Public Health, Saitama, Japan E-mail:
| | - Marina Tokuyasu
- Department of Environmental Health, National Institute of Public Health, Saitama, Japan E-mail:
| | - Takanori Masuda
- Department of Environmental Health, National Institute of Public Health, Saitama, Japan E-mail:
| | - Michihiro Akiba
- Department of Environmental Health, National Institute of Public Health, Saitama, Japan E-mail:
| |
Collapse
|
31
|
Otani T, Iwamoto H, Horimasu Y, Yamaguchi K, Sakamoto S, Masuda T, Miyamoto S, Nakashima T, Fujitaka K, Hamada H, Hattori N. Effect of dupilumab in a patient with severe asthma complicated with recurrent anaphylaxis: a case report. J Investig Allergol Clin Immunol 2022:0. [DOI: 10.18176/jiaci.0840] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
32
|
Masuda T, Funama Y, Nakaura T, Sato T, Tahara M, Yamashita Y, Masuda S, Yoshiura T, Oku T, Arao S, Hiratsuka J, Awai K. Influence of contrast enhancement at the contrast injection location for the arm or leg in neonatal and infant patients during cardiac computed tomography. Radiología (English Edition) 2022; 64:525-532. [DOI: 10.1016/j.rxeng.2021.10.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2021] [Accepted: 07/13/2021] [Indexed: 10/18/2022]
|
33
|
Nonaka H, Masuda T, Yoneyama M, Tahara M, Okano M, Morikawa Y, Sanada K, Sato T. Pitfall for systemic artery aneurysms evaluation using electrocardiogram-gated subtracted three-dimensional fast spin echo sequence of magnetic resonance imaging in patients with Kawasaki disease. Radiol Case Rep 2022; 17:1440-1444. [PMID: 35265237 PMCID: PMC8899111 DOI: 10.1016/j.radcr.2022.01.083] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2021] [Revised: 01/24/2022] [Accepted: 01/25/2022] [Indexed: 11/26/2022] Open
Abstract
Kawasaki disease (KD) is described as a syndrome that causes both coronary and systemic artery aneurysms (SAAs). This report describes the pitfall for SAAs’ evaluation when using electrocardiogram (ECG)-gated subtracted three-dimensional fast spin echo (3D FSE) sequence of magnetic resonance imaging in KD patients. A 12-year-old male was diagnosed with KD at 3 months of age. We acquired ECG-gated 3D FSE images in the diastole and systole phases with coronal sections. Subtraction was then performed from diastolic phase imaging to systolic phase imaging. A 15.5 mm right axillary artery aneurysm and an 8.0 mm left axillary artery aneurysm were identified with ECG-gated 3D FSE in the diastolic phase. However, we observed signal loss in the right axillary artery aneurysm when subtraction was performed to selectively detect arteries; further, the brachial artery was poorly detected. ECG-gated subtracted 3D FSE sequence of magnetic resonance imaging can compromise the image quality of both aneurysm and peripheral artery images when detecting SAAs.
Collapse
|
34
|
Masuda T, Funama Y, Nakaura T, Sato T, Okimoto T, Gotanda R, Arao K, Imaizumi H, Arao S, Ono A, Hiratsuka J, Awai K. Radiation dose reduction method combining the ECG-Edit function and high helical pitch in retrospectively-gated CT angiography. Radiography (Lond) 2022; 28:766-771. [PMID: 35428572 DOI: 10.1016/j.radi.2022.03.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Revised: 03/14/2022] [Accepted: 03/17/2022] [Indexed: 11/26/2022]
Abstract
INTRODUCTION The purpose of this study was to demonstrate that dose reduction does not compromise image quality when combining high helical pitch (HP) and the ECG-Edit function during low HP retrospectively gated computed tomography angiography (CTA). METHODS This study made use of a pulsating cardiac phantom (ALPHA 1 VTPC). The heart rate (HR) of the cardiac phantom was changed in five intervals, every 5 beats per minute (bpm), from 40 to 60 bpm. Evaluation of a range of HR was important because data loss might occur when combining a low HR and high HP. We performed retrospectively gated CTA scans five times using a low HP (0.16) and high HP (0.24), for each of the five HR intervals, using a 64-detector row CT scanner. The CT volume dose index (CTDIvol) was recorded from the CT console of each scan. For the images with data loss, data were repaired using the ECG-Edit function. We compared the CTDIvol, estimated cardiac phantom volume, and the visualization of the coronary ladder phantom between HP 0.16, with or without repaired HP 0.24, using the ECG-Edit function. RESULTS Data loss occurred with a HR of 40 bpm and 45 bpm when using HP 0.24. The CTDIvol was reduced by approximately 33% with HP 0.24 when compared with HP 0.16. There were no significant differences in the mean cardiac motion phantom volume and visualization scores between HP 0.16 and with and without repaired HP 0.24 using the ECG-Edit function (p < 0.05). CONCLUSION The ECG-Edit function is potential useful for repairing the lost data in patients with a low HR, and when combined with a high HP, it is possible to reduce the radiation dose by approximately 33%. IMPLICATIONS FOR PRACTICE The ECG-Edit function and high HP may be a viable option in pediatric CTA studies.
Collapse
Affiliation(s)
- T Masuda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki-city, Okayama 701-0193, Japan.
| | - Y Funama
- Department of Medical Physics, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japan
| | - T Nakaura
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto 860-8556, Japan
| | - T Sato
- Department of Diagnostic Radiology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - T Okimoto
- Department of Cardiovascular Internal Medicine, Edogawa Hospital, Tokyo, Japan
| | - R Gotanda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki-city, Okayama 701-0193, Japan
| | - K Arao
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki-city, Okayama 701-0193, Japan
| | - H Imaizumi
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki-city, Okayama 701-0193, Japan
| | - S Arao
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki-city, Okayama 701-0193, Japan
| | - A Ono
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki-city, Okayama 701-0193, Japan
| | - J Hiratsuka
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki-city, Okayama 701-0193, Japan
| | - K Awai
- Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima, Japan
| |
Collapse
|
35
|
Ishibashi T, Masuda T, Kato M, Yamashita Y, Takei Y, Tsukamoto A, Matsumoto K, Sakamoto H. NATIONWIDE SURVEY OF RADIATION EXPOSURE FOR RADIOFREQUENCY CATHETER ABLATION FOR PULMONARY VEIN ISOLATION AND NONPULMONARY VEIN ISOLATION IN JAPAN. Radiat Prot Dosimetry 2022; 198:16-22. [PMID: 35021232 DOI: 10.1093/rpd/ncab185] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/01/2021] [Revised: 12/17/2021] [Accepted: 12/19/2021] [Indexed: 06/14/2023]
Abstract
To propose typical values for the arrhythmia region between pulmonary vein isolation (PVI) and nonpulmonary vein isolation (non-PVI) in Japan. A nationwide questionnaire was posted to 343 facilities, to which 125 facilities (36.4%) responded. Results is the median for PVI and non-PVI were in terms of Ka,r (317 and 196 mGy), PKA (40.8 and 26.3 Gy.cm2), FT (43.0 and 27.3 min), and CI (326 and 102 images). When comparing PVI and non-PVI procedures, there were significant differences in Ka, r, PKA, FT, and CI (p < 0.05). In other words, by classifying into two types, PVI and non-PVI, we contributed to the establishment of typical values in Japan's RFCA.
Collapse
Affiliation(s)
- Toru Ishibashi
- Department of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - Takanori Masuda
- Department of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - Mamoru Kato
- Department of Radiological Technology, Tsuchiya General Hospital, 3-30 Nakajima-cho, Naka-ku, Hiroshima 730-8655, Japan
| | - Yukari Yamashita
- Department of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - Yasutaka Takei
- Department of Radiological Technology, Faculty of Health Science and Technology, 288 Matsushima, Kurashiki-City, Okayama 701-0193, Japan
| | - Atsuko Tsukamoto
- Department of Radiology, NTT Medical Center Tokyo, 5-9-22 Higashi-Gotanda, Shinagawa-ku, Tokyo 141-8625, Japan
| | - Kazuma Matsumoto
- Department of Clinical Radiology, Hyogo College of Medicine College Hospital, 1-3-6 Minatojima, Chuo-ku, Kobe City, Hyogo 663-8501, Japan
| | - Hajime Sakamoto
- Department of Radiological Technology, Faculty of Health Science, Juntendo University, 2-1-1 Hongo, bunkyou-ku, Tokyo 113-8421, Japan
| |
Collapse
|
36
|
Takabe Y, Fujiyama M, Yamasaki Y, Masuda T. Influences of electrode distance and electrolysis time on phosphorus precipitation and composition during electrolysis of anaerobic digestion effluent. Sci Total Environ 2022; 803:150114. [PMID: 34525711 DOI: 10.1016/j.scitotenv.2021.150114] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/11/2021] [Revised: 08/29/2021] [Accepted: 08/30/2021] [Indexed: 06/13/2023]
Abstract
Global demand for phosphorus (P) is increasing, which has led to concerns over future drought and has driven efforts to recover P from wastewater streams for reuse. In this study, platinum-coated titanium electrodes were applied to the electrochemical precipitation of P from anaerobic digestion effluent that was collected from a domestic wastewater treatment plant. The influence of the electrode distance on P removal and precipitation was investigated. In addition, the influence of the electrolysis time on the chemical structure and composition of the P precipitate was evaluated from the viewpoint of utilising the P precipitate as fertiliser. Regardless of the electrode distance (10, 5 and 1 mm), PO43-, Ca2+ and Mg2+ were removed. The bulk solution pH increased during electrolysis because of the consumption of generated H+ as HCO3- transitioned to H2CO3 near the anode. A greater increase in the bulk solution pH was observed when the electrode distance was narrowed because of the enhanced H+ consumption. Narrowing the electrode distance reduced the energy consumption for P precipitation. The increase in the bulk solution pH with the narrowing electrode distance changed the dominant P precipitation pathway from onto the cathode to in the bulk solution. X-ray diffraction spectra of the precipitates showed that increasing the electrolysis time transformed amorphous P to hydroxyapatite and struvite. Most P existed in a citric acid-soluble form, which is recommended for use as a slow P release fertiliser. There were no significant changes in the citric acid-soluble P content of the precipitates with increasing electrolysis time. Therefore, increasing the electrolysis time has little influence on the suitability of the precipitate as a slow P release fertiliser.
Collapse
Affiliation(s)
- Yugo Takabe
- Graduate School of Engineering, Tottori University, 4-101 Koyama-Minami, Tottori 6808552, Japan.
| | - Masaya Fujiyama
- Graduate School of Engineering, Tottori University, 4-101 Koyama-Minami, Tottori 6808552, Japan
| | - Yukiyo Yamasaki
- Materials and Resources Research Group, Innovative Materials and Resources Research Center, Public Works Research Institute, 1-6 Minamihara, Tsukuba, Ibaraki 3058516, Japan
| | - Takanori Masuda
- Graduate School of Engineering, Tottori University, 4-101 Koyama-Minami, Tottori 6808552, Japan
| |
Collapse
|
37
|
Masuda T, Funama Y, Nakaura T, Sato T, Tahara M, Masuda S, Yoshiura T, Gotanda R, Arao K, Imaizumi H, Arao S, Hiratsuka J, Awai K. Effect of injection duration on contrast enhancement during cardiac computed tomography angiography in newborns and infants. Radiography (Lond) 2021; 28:440-446. [PMID: 34844859 DOI: 10.1016/j.radi.2021.11.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2021] [Revised: 11/08/2021] [Accepted: 11/10/2021] [Indexed: 10/19/2022]
Abstract
INTRODUCTION To investigate how changing the injection duration at cardiac computed tomography angiography (CCTA) affects contrast enhancement in newborns and infants. METHODS Included were 142 newborns and infants with confirmed congenital heart disease who underwent CCTA between January 2015 and December 2018. In group 1 (n = 71 patients), the injection duration was 8 s; in group 2 (n = 71) it was 16 s. Our findings were assessed by one-to-one matching analysis to estimate the propensity score of each patient. We compare the CT number for the pulmonary artery (PA), ascending aorta (AAO), left superior vena cava (SVC), AAO and PA enhancement ratio, and the scores for visualization between the two groups. RESULTS In group 1, median CT number and ranges was 345 (211-591) HU in the AAO, 324 (213-567) HU in the PA, and 62 (1-70) HU in the SVC. These values were 465 (308-669) HU, 467 (295-638) HU, and 234 (67-443) HU, respectively, in group 2 (p < 0.05). The median score for volume-rendering visualization on 3D images of the CCTA was 2 in group 1 and 3 in group 2; the score for visualization of the left SVC of the maximum intensity projection images was 2 in group 1 and 3 in group 2 (p < 0.05). The CT number for the AAO and PA enhancement ratio was 15.2 in group 1 and 9.2 in group 2 (p < 0.05). CONCLUSION The 16-sec injection protocol yielded significantly higher CT numbers for the AAO, PA, and the SVC than the 8-sec injection protocol; the visualization scores were also significantly higher in group 2. IMPLICATIONS FOR PRACTICE In newborns and infants, the longer injection time for CCTA yields stable and higher contrast enhancement at identical CM concentrations.
Collapse
Affiliation(s)
- T Masuda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan.
| | - Y Funama
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto, 860-8556, Japan
| | - T Nakaura
- Department of Medical Physics, Faculty of Life Sciences, Kumamoto University, Kumamoto, 1-1-1 Honjo, Kumamoto, 860-8556, Japan
| | - T Sato
- Department of Diagnostic Radiology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima, 730-8655, Japan
| | - M Tahara
- Department of Pediatric Cardiology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima, 730-8655, Japan
| | - S Masuda
- Department of Radiological Technology, Kawamura Clinic, Otemachi, Naka-ku, Hiroshima, 730-0051, Japan
| | - T Yoshiura
- Department of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima, 730-8655, Japan
| | - R Gotanda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan
| | - K Arao
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan
| | - H Imaizumi
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan
| | - S Arao
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan
| | - J Hiratsuka
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan
| | - K Awai
- Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Kasumi 1-2-3 Minami-ku, Hiroshima, 734-8551, Japan
| |
Collapse
|
38
|
Gotoh M, Nakaura T, Funama Y, Morita K, Sakabe D, Uetani H, Nagayama Y, Kidoh M, Hatemura M, Masuda T, Hirai T. Virtual magnetic resonance lumbar spine images generated from computed tomography images using conditional generative adversarial networks. Radiography (Lond) 2021; 28:447-453. [PMID: 34774411 DOI: 10.1016/j.radi.2021.10.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2021] [Revised: 10/07/2021] [Accepted: 10/09/2021] [Indexed: 11/26/2022]
Abstract
INTRODUCTION The aim of this study was to generate virtual Magnetic resonance (MR) from computed tomography (CT) using conditional generative adversarial networks (cGAN). METHODS We selected examinations from 22 adults who obtained their CT and MR lumbar spine examinations. Overall, 4 examinations were used as test data, and 18 examinations were used as training data. A cGAN was trained to generate virtual MR images from the CT images using the corresponding MR images as targets. After training, the generated virtual MR images from test data in epochs 1, 10, 50, 100, 500, and 1000 were compared with the original ones using the mean square error (MSE) and structural similarity index (SSIM). Additionally, two radiologists also performed qualitative assessments. RESULTS The MSE of the virtual MR images decreased as the epoch of the cGANs increased from the original CT images: 8876.7 ± 1192.9 (original CT), 1567.5 ± 433.9 (Epoch 1), 1242.4 ± 442.0 (Epoch 10), 1065.8 ± 478.1 (Epoch 50), 1276.1 ± 718.9 (Epoch 100), 1046.7 ± 488.2 (Epoch 500), and 1031.7 ± 400.0 (Epoch 1000). No considerable differences were observed in the qualitative evaluation between the virtual MR images and the original ones, except in the structure of the spinal canal. CONCLUSION Virtual MR lumbar spine images using cGANs could be a feasible technique to generate near-MR images from CT without MR examinations for evaluation of the vertebral body and intervertebral disc. IMPLICATIONS FOR PRACTICE Virtual MR lumbar spine images using cGANs can offer virtual CT images with sufficient quality for attenuation correction for PET or dose planning in radiotherapy.
Collapse
Affiliation(s)
- M Gotoh
- Department of Radiology, Kumamoto University Hospital, Japan
| | - T Nakaura
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, Japan.
| | - Y Funama
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, Japan
| | - K Morita
- Department of Radiology, Kumamoto University Hospital, Japan
| | - D Sakabe
- Department of Radiology, Kumamoto University Hospital, Japan
| | - H Uetani
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, Japan
| | - Y Nagayama
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, Japan
| | - M Kidoh
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, Japan
| | - M Hatemura
- Department of Radiology, Kumamoto University Hospital, Japan
| | - T Masuda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Japan
| | - T Hirai
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, Japan
| |
Collapse
|
39
|
Masuda T, Nakaura T, Funama Y, Sato T, Arataki K, Oku T, Yoshiura T, Masuda S, Gotanda R, Arao K, Imaizumi H, Arao S, Hiratsuka J, Awai K. Enhancement rate of venous phase to portal venous phase computed tomography and its correlation with ultrasound elastography determination of liver fibrosis. Radiography (Lond) 2021; 28:412-419. [PMID: 34702666 DOI: 10.1016/j.radi.2021.10.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2021] [Revised: 10/06/2021] [Accepted: 10/09/2021] [Indexed: 11/16/2022]
Abstract
INTRODUCTION This study aimed to compare the correlation between the computed tomography (CT) enhancement rate of the venous to portal venous phase (VP-ER) and the extracellular volume (ECV) fraction with shear-wave ultrasound elastography (USE) findings in patients with liver fibrosis. METHODS We included 450 patients with clinically suspected liver cirrhosis who underwent triphasic dynamic CT studies and USE. We compared the USE results with the unenhanced CT phase, with enhancement in the hepatic artery phase (HAP), portal venous phase (PVP), and venous phase (VP), and with the ECV fraction and the VP-ER. We also compared the area under the curve (AUC) of the receiver operating characteristic (ROC) curve of the ECV fraction and VP-ER with that of the values obtained with USE. RESULTS The VP-ER was the most highly correlated with the liver stiffness value determined with USE (Pearson's correlation coefficient: r = 0.37), followed by enhancement in the PVP (r = -0.25), CT number on unenhanced CT scans (r = -0.22), the ECV fraction (r = 0.19), enhancement in the VP (r = 0.059), and enhancement in the HAP (r = -0.023) (all p < 0.01). The VP-ER showed a significantly higher AUC than the ECV fraction (0.75 vs 0.62) when the liver stiffness was >15 kPa in USE studies (p = 0.04). CONCLUSION Compared to the ECV fraction, the VP-ER is more useful for predicting all degrees of liver fibrosis on routine triphasic dynamic CT images. IMPLICATIONS FOR PRACTICE Although improvement is needed, the VP-ER has a higher diagnostic ability for liver fibrosis than the ECV fraction in clinical practice.
Collapse
Affiliation(s)
- T Masuda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki-city, Okayama, 701-0193, Japan.
| | - T Nakaura
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto, 860-8556, Japan
| | - Y Funama
- Department of Medical Physics, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japan
| | - T Sato
- Department of Diagnostic Radiology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima, 730-8655, Japan
| | - K Arataki
- Department of Gastroenterology Internal Medicine, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima, 730-8655, Japan
| | - T Oku
- Department of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima, 730-8655, Japan
| | - T Yoshiura
- Department of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima, 730-8655, Japan
| | - S Masuda
- Department of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima, 730-8655, Japan
| | - R Gotanda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki-city, Okayama, 701-0193, Japan
| | - K Arao
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki-city, Okayama, 701-0193, Japan
| | - H Imaizumi
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki-city, Okayama, 701-0193, Japan
| | - S Arao
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki-city, Okayama, 701-0193, Japan
| | - J Hiratsuka
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki-city, Okayama, 701-0193, Japan
| | - K Awai
- Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima, Japan
| |
Collapse
|
40
|
Masuda T, Funama Y, Nakaura T, Sato T, Tahara M, Yamashita Y, Yoshiura T, Masuda S, Gotanda R, Arao K, Imaizumi H, Arao S, Hiratsuka J, Awai K. Efficacy of the spiral flow generating extended tube during paediatric CCTA. Radiography (Lond) 2021; 28:420-425. [PMID: 34702665 DOI: 10.1016/j.radi.2021.10.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2021] [Revised: 09/30/2021] [Accepted: 10/09/2021] [Indexed: 11/19/2022]
Abstract
INTRODUCTION To compare the computed tomography (CT) number for paediatric cardiac computed tomography angiography (CCTA) and visualisation score of the three-dimensional (3D) images using the conventional T-shaped extended tube (T-tube) and spiral flow-generating extended tube (spiral-tube) connected between the contrast injector and cannula. METHODS In total, 108 patients suspected to have congenital heart disease (CHD) were considered for inclusion. We utilised the T-tube for intravenous contrast and spiral-tube in 54 patients each. Observers individually inspected randomized volume rendering images of the internal thoracic artery, each acquired from the with or without spiral-tube groups, using a four-point scale. We compared the mean CT number of the ascending aorta (AAO) and pulmonary artery (PA), contrast noise ratio (CNR), CT number for the AAO and PA enhancement ratio, and the visualisation scores between the groups. RESULTS There were no significant differences in patient characteristics between the with or without spiral-tube groups (p > 0.05). The mean CT number ±standard deviation for the AAO and PA, and the CNR without or with spiral-tube groups were 441.2 ± 89.2 and 489.8 ± 86.1 HU for the AAO, 436.3 ± 100.6 and 475.3 ± 85.2 HU for the PA, and 9.5 ± 2.2 and 10.8 ± 2.4 for the CNR, respectively (p < 0.05). In the spiral-tube group, the CT number, CNR, and visualisations score of the 3D images were significantly higher for the AAO and PA than those in the T-tube group (p < 0.05). CONCLUSION The spiral-tube proved to be beneficial in improving the CT number for the AAO and PA, CNR, and visualisation score compared with the conventional T-tube during paediatric CCTA. IMPLICATIONS FOR PRACTICE The spiral-tube may allow the visualisation of smaller blood vessels than those visualised by the conventional T-tube for paediatric patients in CCTA.
Collapse
Affiliation(s)
- T Masuda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan.
| | - Y Funama
- Department of Medical Physics, Faculty of Life Sciences, Kumamoto University, Kumamoto, 1-1-1 Honjo, Kumamoto, 860-8556, Japan
| | - T Nakaura
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto, 860-8556, Japan
| | - T Sato
- Department of Diagnostic Radiology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima, 730-8655, Japan
| | - M Tahara
- Department of Pediatric Cardiology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima, 730-8655, Japan
| | - Y Yamashita
- Department of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima, 730-8655, Japan
| | - T Yoshiura
- Department of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima, 730-8655, Japan
| | - S Masuda
- Department of Radiological Technology, Kawamura Clinic, Otemachi, Naka-ku, Hiroshima, 730-0051, Japan
| | - R Gotanda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan
| | - K Arao
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan
| | - H Imaizumi
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan
| | - S Arao
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan
| | - J Hiratsuka
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan
| | - K Awai
- Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Kasumi 1-2-3 Minami-ku, Hiroshima, 734-8551, Japan
| |
Collapse
|
41
|
Ueo H, Ueo H, Minoura I, Gamachi A, Doi T, Yamaguchi M, Yamashita T, Tsuda H, Moriya T, Yamaguchi R, Kozuka Y, Sasaki T, Masuda T, Kai Y, Kubota Y, Urano Y, Mori M, Mimori K. Clinical usefulness of a novel fluorescence technique for the intraoperative diagnosis of surgical margins in patients with breast cancer. Br J Surg 2021; 108:e340-e342. [PMID: 34428279 DOI: 10.1093/bjs/znab265] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2021] [Revised: 06/02/2021] [Accepted: 06/22/2021] [Indexed: 11/12/2022]
Abstract
In both 5- and 15-min data, FI was significantly higher in malignant tissues than in benign tissues. The diagnostic accuracy was similar at 5 and 15 min. Therefore, the 5-min FI was enough applying in the further analyses.
Collapse
Affiliation(s)
- H Ueo
- Department of Surgery and Sciences, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan.,Ueo Breast Cancer Hospital, Oita, Japan
| | - H Ueo
- Ueo Breast Cancer Hospital, Oita, Japan
| | - I Minoura
- Goryo Chemical, Inc., Sapporo, Japan
| | - A Gamachi
- Department of Pathology, Almeida Memorial Hospital, Oita, Japan
| | - T Doi
- Breast Cancer Centre, Shonan Memorial Hospital, Kamakura, Japan
| | - M Yamaguchi
- Department of Breast Surgery, JCHO Kurume General Hospital, Kurume, Japan
| | - T Yamashita
- Department of Breast and Endocrine Surgery, Kanagawa Cancer Centre, Yokohama, Japan
| | - H Tsuda
- Department of Basic Pathology, National Defence Medical College, Tokorozawa, Japan
| | - T Moriya
- Department of Pathology, Kawasaki Medical School, Kurashiki, Japan
| | - R Yamaguchi
- Department of Pathology and Laboratory Medicine, Kurume University Medical Centre, Kurume, Japan
| | - Y Kozuka
- Department of Pathology, Mie University Hospital, Tsu, Japan
| | - T Sasaki
- Department of Next-Generation Pathology Information and Networking, Faculty of Medicine, The University of Tokyo, Tokyo, Japan
| | - T Masuda
- Department of Surgery, Kyushu University Beppu Hospital, Beppu, Japan
| | - Y Kai
- Ueo Breast Cancer Hospital, Oita, Japan
| | - Y Kubota
- Ueo Breast Cancer Hospital, Oita, Japan
| | - Y Urano
- Graduate School of Medicine and Graduate School of Pharmaceutical Sciences, The University of Tokyo, Tokyo, Japan
| | - M Mori
- Department of Surgery and Sciences, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - K Mimori
- Department of Surgery, Kyushu University Beppu Hospital, Beppu, Japan
| |
Collapse
|
42
|
Masuda T, Nakaura T, Funama Y, Oda S, Okimoto T, Sato T, Noda N, Yoshiura T, Baba Y, Arao S, Hiratsuka J, Awai K. Deep learning with convolutional neural network for estimation of the characterisation of coronary plaques: Validation using IB-IVUS. Radiography (Lond) 2021; 28:61-67. [PMID: 34404578 DOI: 10.1016/j.radi.2021.07.024] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Revised: 07/08/2021] [Accepted: 07/27/2021] [Indexed: 10/20/2022]
Abstract
INTRODUCTION Deep learning approaches have shown high diagnostic performance in image classifications, such as differentiation of malignant tumors and calcified coronary plaque. However, it is unknown whether deep learning is useful for characterizing coronary plaques without the presence of calcification using coronary computed tomography angiography (CCTA). The purpose of this study was to compare the diagnostic performance of deep learning with a convolutional neural network (CNN) with that of radiologists in the estimation of coronary plaques. METHODS We retrospectively enrolled 178 patients (191 coronary plaques) who had undergone CCTA and integrated backscatter intravascular ultrasonography (IB-IVUS) studies. IB-IVUS diagnosed 81 fibrous and 110 fatty or fibro-fatty plaques. We manually captured vascular short-axis images of the coronary plaques as Portable Network Graphics (PNG) images (150 × 150 pixels). The display window level and width were 100 and 700 Hounsfield units (HU), respectively. The deep-learning system (CNN; GoogleNet Inception v3) was trained on 153 plaques; its performance was tested on 38 plaques. The area under the curve (AUC) obtained by receiver operating characteristic analysis of the deep learning system and by two board-certified radiologists was compared. RESULTS With the CNN, the AUC and the 95% confidence interval were 0.83 and 0.69-0.96, respectively; for radiologist 1 they were 0.61 and 0.42-0.80; for radiologist 2 they were 0.68 and 0.51-0.86, respectively. The AUC for CNN was significantly higher than for radiologists 1 (p = 0.04); for radiologist 2 it was not significantly different (p = 0.22). CONCLUSION DL-CNN performed comparably to radiologists for discrimination between fatty and fibro-fatty plaque on CCTA images. IMPLICATIONS FOR PRACTICE The diagnostic performance of the CNN and of two radiologists in the assessment of 191 ROIs on CT images of coronary plaques whose type corresponded with their IB-IVUS characterization was comparable.
Collapse
Affiliation(s)
- T Masuda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki-city, Okayama 701-0193, Japan.
| | - T Nakaura
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto 860-8556, Japan
| | - Y Funama
- Department of Medical Physics, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japan
| | - S Oda
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto 860-8556, Japan
| | - T Okimoto
- Department of Cardiovascular Internal Medicine, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - T Sato
- Department of Diagnostic Radiology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - N Noda
- Department of Radiological Technologist, Medical Corporation JR Hiroshima Hospital, Hiroshima, Japan
| | - T Yoshiura
- Department of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - Y Baba
- Saitama Medical University International Medical Center, 1397-1, Yamane, Hidaka-City, Saitama-Pref, 350-1298, Japan
| | - S Arao
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki-city, Okayama 701-0193, Japan
| | - J Hiratsuka
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki-city, Okayama 701-0193, Japan
| | - K Awai
- Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima, Japan
| |
Collapse
|
43
|
Masuda T, Funama Y, Nakaura T, Sato T, Tahara M, Takei Y, Yamashita Y, Oku T, Masuda S, Kiguchi M, Awai K. USE OF VACUUM MATTRESSES CAN REDUCE THE ABSORBED DOSE DURING PEDIATRIC CT. Radiat Prot Dosimetry 2021; 194:201-207. [PMID: 34227663 DOI: 10.1093/rpd/ncab102] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/05/2020] [Revised: 05/10/2021] [Accepted: 06/12/2021] [Indexed: 06/13/2023]
Abstract
To evaluate and compare the absorbed dose and image quality when applying a commercially produced fixation device (group A) and a vaccum mattress fixation device to pediatric patients (group B). We compared the absorbed dose and image noise between the groups at the phantom and clinical study. For phantom study, the measurement absorbed dose for a real time skin dosimeter was 3.0 mGy at the group A and 1.9 mGy at the group B (p < 0.05). For clinical study, computed tomography dose index product, dose-length and effective radiation dose were significantly lower with the group B compared to the group A, (3.4 mGy, 27.0 mGy-cm, and 2.2 mSv vs 4.4 mGy, and 36.7 mGy-cm, and 3.0 mSv), p < 0.05 for all comparisons. Compared to the commercially produced fixation device, the vaccum mattress fixation device composed of a less absorptive material enabled a reduction in the absorbed dose while maintaining the image quality during pediatric CT examinations.
Collapse
Affiliation(s)
- Takanori Masuda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama 701-0193, Japan
| | - Yoshinori Funama
- Department of Medical Physics, Faculty of Life Sciences, Kumamoto University, Kumamoto, 1-1-1 Honjo, Kumamoto 860-8556, Japan
| | - Takeshi Nakaura
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto 860-8556, Japan
| | - Tomoyasu Sato
- Department of Diagnostic Radiology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - Masahiro Tahara
- Department of Pediatric cardiology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - Yasutaka Takei
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama 701-0193, Japan
| | - Yukari Yamashita
- Department of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - Takayuki Oku
- Department of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - Shouko Masuda
- Department of Radiological Technology, kawamura clinic, Otemachi, Naka-ku, Hiroshima 730-0051, Japan
| | - Masao Kiguchi
- Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Kasumi 1-2-3 Minami-ku, Hiroshima 734-8551, Japan
| | - Kazuo Awai
- Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Kasumi 1-2-3 Minami-ku, Hiroshima 734-8551, Japan
| |
Collapse
|
44
|
Affiliation(s)
- Takanori Masuda
- Department of Radiological Technology,Faculty of Health Science and Technology,Kawasaki University of Medical Welfare
| |
Collapse
|
45
|
Masuda T, Funama Y, Nakaura T, Sato T, Okimoto T, Masuda S, Yamashita Y, Yoshiura T, Noda N, Baba Y, Awai K. Diagnostic performance of computed tomography digital subtraction angiography of the lower extremities during haemodialysis in patients with suspected peripheral artery disease. Radiography (Lond) 2021; 27:888-896. [PMID: 33820690 DOI: 10.1016/j.radi.2021.02.007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2020] [Revised: 01/22/2021] [Accepted: 02/11/2021] [Indexed: 11/30/2022]
Abstract
INTRODUCTION With intra-arterial digital subtraction angiography (DSA) considered as the gold standard, we compared the diagnostic value of computed tomography angiography (CTA) and computed tomography-digital subtraction angiography (CT-DSA in hemodialysis (HD) patients suspected of having lower limb peripheral artery disease (PAD). METHODS In this retrospective study, we enrolled 220 HD patients with suspected PAD. CT-DSA images were obtained by subtracting unenhanced images from enhanced images. The research team calculated the area under the curve (AUC), sensitivity, specificity, positive and negative predictive value (PPV, NPV), and recorded the diagnostic accuracy between the CTA and CT-DSA images using the DSA as gold standard. Visual evaluation of calcifications in the peripheral arteries were also compared between CTA and CT-DSA images. RESULTS At the above-knee level, the CTA AUC [95% confidence interval (CI)] was 0.68 (CI 0.64-0.72), sensitivity and specificity were 60 and 81%, PPV and NPV were 85 and 53%, and accuracy was 67%. Below the knee, these values were 0.66 (CI 0.62-0.70), 71 and 79%, 79 and 47%, and 66%. For CT-DSA, above-knee, the AUC [95% CI] was 0.88 (CI 0.85-0.91), sensitivity and specificity were 84 and 92%, PPV and NPV were 89 and 97%, and accuracy was 93%. Below the knee, these values were 0.95 (CI 0.93-0.97), 95 and 93%, 96 and 83%, and 93%. The scores for the visualization of calcification in the peripheral arteries was significantly higher for CT-DSA than CTA (p < 0.05). CONCLUSIONS CT-DSA helps to assess stenotic PAD with high calcification in the lower extremities of HD patients. IMPLICATIONS FOR PRACTICE On CT-DSA images, the severity of vascular calcification can be assessed for HD patients suspected of PAD of the lower extremities.
Collapse
Affiliation(s)
- T Masuda
- Department of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan; Saitama Medical University International Medical Center, 1397-1, Yamane, Hidaka-City, Saitama-Pref 350-1298, Japan.
| | - Y Funama
- Department of Medical Physics, Faculty of Life Sciences, Kumamoto University, Kumamoto, 1-1-1 Honjo, Kumamoto 860-8556, Japan
| | - T Nakaura
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto 860-8556, Japan
| | - T Sato
- Department of Diagnostic Radiology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - T Okimoto
- Department of Cardiovascular Internal Medicine, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - S Masuda
- Department of Radiological Technology, Kawamura Clinic, Otemachi, Naka-ku, Hiroshima 730-0051, Japan
| | - Y Yamashita
- Department of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - T Yoshiura
- Department of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - N Noda
- Department of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - Y Baba
- Saitama Medical University International Medical Center, 1397-1, Yamane, Hidaka-City, Saitama-Pref 350-1298, Japan
| | - K Awai
- Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Kasumi 1-2-3 Minami-ku, Hiroshima 734-8551, Japan
| |
Collapse
|
46
|
Ahn JK, Beckford B, Campbell M, Chen SH, Comfort J, Dona K, Farrington MS, Hanai K, Hara N, Haraguchi H, Hsiung YB, Hutcheson M, Inagaki T, Isoe M, Kamiji I, Kato T, Kim EJ, Kim JL, Kim HM, Komatsubara TK, Kotera K, Lee SK, Lee JW, Lim GY, Lin QS, Lin C, Luo Y, Mari T, Masuda T, Matsumura T, Mcfarland D, McNeal N, Miyazaki K, Murayama R, Nakagiri K, Nanjo H, Nishimiya H, Noichi Y, Nomura T, Nunes T, Ohsugi M, Okuno H, Redeker JC, Sanchez J, Sasaki M, Sasao N, Sato T, Sato K, Sato Y, Shimizu N, Shimogawa T, Shinkawa T, Shinohara S, Shiomi K, Shiraishi R, Su S, Sugiyama Y, Suzuki S, Tajima Y, Taylor M, Tecchio M, Togawa M, Toyoda T, Tung YC, Vuong QH, Wah YW, Watanabe H, Yamanaka T, Yoshida HY, Zaidenberg L. Study of the K_{L}→π^{0}νν[over ¯] Decay at the J-PARC KOTO Experiment. Phys Rev Lett 2021; 126:121801. [PMID: 33834796 DOI: 10.1103/physrevlett.126.121801] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2020] [Accepted: 02/18/2021] [Indexed: 06/12/2023]
Abstract
The rare decay K_{L}→π^{0}νν[over ¯] was studied with the dataset taken at the J-PARC KOTO experiment in 2016, 2017, and 2018. With a single event sensitivity of (7.20±0.05_{stat}±0.66_{syst})×10^{-10}, three candidate events were observed in the signal region. After unveiling them, contaminations from K^{±} and scattered K_{L} decays were studied, and the total number of background events was estimated to be 1.22±0.26. We conclude that the number of observed events is statistically consistent with the background expectation. For this dataset, we set an upper limit of 4.9×10^{-9} on the branching fraction of K_{L}→π^{0}νν[over ¯] at the 90% confidence level.
Collapse
Affiliation(s)
- J K Ahn
- Department of Physics, Korea University, Seoul 02841, Republic of Korea
| | - B Beckford
- Department of Physics, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - M Campbell
- Department of Physics, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - S H Chen
- Department of Physics, National Taiwan University, Taipei, Taiwan 10617, Republic of China
| | - J Comfort
- Department of Physics, Arizona State University, Tempe, Arizona 85287, USA
| | - K Dona
- Department of Physics, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - M S Farrington
- Enrico Fermi Institute, University of Chicago, Chicago, Illinois 60637, USA
| | - K Hanai
- Department of Physics, Osaka University, Toyonaka, Osaka 560-0043, Japan
| | - N Hara
- Department of Physics, Osaka University, Toyonaka, Osaka 560-0043, Japan
| | - H Haraguchi
- Department of Physics, Osaka University, Toyonaka, Osaka 560-0043, Japan
| | - Y B Hsiung
- Department of Physics, National Taiwan University, Taipei, Taiwan 10617, Republic of China
| | - M Hutcheson
- Department of Physics, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - T Inagaki
- Institute of Particle and Nuclear Studies, High Energy Accelerator Research Organization (KEK), Tsukuba, Ibaraki 305-0801, Japan
| | - M Isoe
- Department of Physics, Osaka University, Toyonaka, Osaka 560-0043, Japan
| | - I Kamiji
- Department of Physics, Kyoto University, Kyoto 606-8502, Japan
| | - T Kato
- Department of Physics, Osaka University, Toyonaka, Osaka 560-0043, Japan
| | - E J Kim
- Division of Science Education, Jeonbuk National University, Jeonju 54896, Republic of Korea
| | - J L Kim
- Division of Science Education, Jeonbuk National University, Jeonju 54896, Republic of Korea
| | - H M Kim
- Division of Science Education, Jeonbuk National University, Jeonju 54896, Republic of Korea
| | - T K Komatsubara
- Institute of Particle and Nuclear Studies, High Energy Accelerator Research Organization (KEK), Tsukuba, Ibaraki 305-0801, Japan
- J-PARC Center, Tokai, Ibaraki 319-1195, Japan
| | - K Kotera
- Department of Physics, Osaka University, Toyonaka, Osaka 560-0043, Japan
| | - S K Lee
- Division of Science Education, Jeonbuk National University, Jeonju 54896, Republic of Korea
| | - J W Lee
- Department of Physics, Osaka University, Toyonaka, Osaka 560-0043, Japan
| | - G Y Lim
- Institute of Particle and Nuclear Studies, High Energy Accelerator Research Organization (KEK), Tsukuba, Ibaraki 305-0801, Japan
- J-PARC Center, Tokai, Ibaraki 319-1195, Japan
| | - Q S Lin
- Enrico Fermi Institute, University of Chicago, Chicago, Illinois 60637, USA
| | - C Lin
- Department of Physics, National Taiwan University, Taipei, Taiwan 10617, Republic of China
| | - Y Luo
- Enrico Fermi Institute, University of Chicago, Chicago, Illinois 60637, USA
| | - T Mari
- Department of Physics, Osaka University, Toyonaka, Osaka 560-0043, Japan
| | - T Masuda
- Research Institute for Interdisciplinary Science, Okayama University, Okayama 700-8530, Japan
| | - T Matsumura
- Department of Applied Physics, National Defense Academy, Kanagawa 239-8686, Japan
| | - D Mcfarland
- Department of Physics, Arizona State University, Tempe, Arizona 85287, USA
| | - N McNeal
- Department of Physics, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - K Miyazaki
- Department of Physics, Osaka University, Toyonaka, Osaka 560-0043, Japan
| | - R Murayama
- Department of Physics, Osaka University, Toyonaka, Osaka 560-0043, Japan
| | - K Nakagiri
- Department of Physics, Kyoto University, Kyoto 606-8502, Japan
| | - H Nanjo
- Department of Physics, Kyoto University, Kyoto 606-8502, Japan
| | - H Nishimiya
- Department of Physics, Osaka University, Toyonaka, Osaka 560-0043, Japan
| | - Y Noichi
- Department of Physics, Osaka University, Toyonaka, Osaka 560-0043, Japan
| | - T Nomura
- Institute of Particle and Nuclear Studies, High Energy Accelerator Research Organization (KEK), Tsukuba, Ibaraki 305-0801, Japan
- J-PARC Center, Tokai, Ibaraki 319-1195, Japan
| | - T Nunes
- Department of Physics, Osaka University, Toyonaka, Osaka 560-0043, Japan
| | - M Ohsugi
- Department of Physics, Osaka University, Toyonaka, Osaka 560-0043, Japan
| | - H Okuno
- Institute of Particle and Nuclear Studies, High Energy Accelerator Research Organization (KEK), Tsukuba, Ibaraki 305-0801, Japan
| | - J C Redeker
- Enrico Fermi Institute, University of Chicago, Chicago, Illinois 60637, USA
| | - J Sanchez
- Department of Physics, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - M Sasaki
- Department of Physics, Yamagata University, Yamagata 990-8560, Japan
| | - N Sasao
- Research Institute for Interdisciplinary Science, Okayama University, Okayama 700-8530, Japan
| | - T Sato
- Institute of Particle and Nuclear Studies, High Energy Accelerator Research Organization (KEK), Tsukuba, Ibaraki 305-0801, Japan
| | - K Sato
- Department of Physics, Osaka University, Toyonaka, Osaka 560-0043, Japan
| | - Y Sato
- Department of Physics, Osaka University, Toyonaka, Osaka 560-0043, Japan
| | - N Shimizu
- Department of Physics, Osaka University, Toyonaka, Osaka 560-0043, Japan
| | - T Shimogawa
- Department of Physics, Saga University, Saga 840-8502, Japan
| | - T Shinkawa
- Department of Applied Physics, National Defense Academy, Kanagawa 239-8686, Japan
| | - S Shinohara
- Department of Physics, Kyoto University, Kyoto 606-8502, Japan
| | - K Shiomi
- Institute of Particle and Nuclear Studies, High Energy Accelerator Research Organization (KEK), Tsukuba, Ibaraki 305-0801, Japan
- J-PARC Center, Tokai, Ibaraki 319-1195, Japan
| | - R Shiraishi
- Department of Physics, Osaka University, Toyonaka, Osaka 560-0043, Japan
| | - S Su
- Department of Physics, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Y Sugiyama
- Department of Physics, Osaka University, Toyonaka, Osaka 560-0043, Japan
| | - S Suzuki
- Department of Physics, Saga University, Saga 840-8502, Japan
| | - Y Tajima
- Department of Physics, Yamagata University, Yamagata 990-8560, Japan
| | - M Taylor
- Department of Physics, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - M Tecchio
- Department of Physics, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - M Togawa
- Department of Physics, Osaka University, Toyonaka, Osaka 560-0043, Japan
| | - T Toyoda
- Department of Physics, Osaka University, Toyonaka, Osaka 560-0043, Japan
| | - Y-C Tung
- Enrico Fermi Institute, University of Chicago, Chicago, Illinois 60637, USA
| | - Q H Vuong
- Department of Physics, Osaka University, Toyonaka, Osaka 560-0043, Japan
| | - Y W Wah
- Enrico Fermi Institute, University of Chicago, Chicago, Illinois 60637, USA
| | - H Watanabe
- Institute of Particle and Nuclear Studies, High Energy Accelerator Research Organization (KEK), Tsukuba, Ibaraki 305-0801, Japan
- J-PARC Center, Tokai, Ibaraki 319-1195, Japan
| | - T Yamanaka
- Department of Physics, Osaka University, Toyonaka, Osaka 560-0043, Japan
| | - H Y Yoshida
- Department of Physics, Yamagata University, Yamagata 990-8560, Japan
| | - L Zaidenberg
- Department of Physics, University of Michigan, Ann Arbor, Michigan 48109, USA
| |
Collapse
|
47
|
Masuda T, Nakaura T, Funama Y, Sugino K, Sato T, Yoshiura T, Baba Y, Awai K. Machine learning to identify lymph node metastasis from thyroid cancer in patients undergoing contrast-enhanced CT studies. Radiography (Lond) 2021; 27:920-926. [PMID: 33762147 DOI: 10.1016/j.radi.2021.03.001] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2020] [Revised: 02/14/2021] [Accepted: 03/02/2021] [Indexed: 02/07/2023]
Abstract
INTRODUCTION We compared the diagnostic performance of morphological methods such as the major axis, the minor axis, the volume and sphericity and of machine learning with texture analysis in the identification of lymph node metastasis in patients with thyroid cancer who had undergone contrast-enhanced CT studies. METHODS We sampled 772 lymph nodes with histology defined tissue types (84 metastatic and 688 benign lymph nodes) that were visualised on CT images of 117 patients. A support vector machine (SVM), free programming software (Python), and the scikit-learn machine learning library were used to discriminate metastatic-from benign lymph nodes. We assessed 96 texture and 4 morphological features (major axis, minor axis, volume, sphericity) that were reported useful for the differentiation between metastatic and benign lymph nodes on CT images. The area under the curve (AUC) obtained by receiver operating characteristic analysis of univariate logistic regression and SVM classifiers were calculated for the training and testing datasets. RESULTS The AUC for all classifiers in training and testing datasets was 0.96 and 0.86, at the SVM for machine learning. When we applied conventional methods to the training and testing datasets, the AUCs were 0.63 and 0.48 for the major axis, 0.70 and 0.44 for the minor axis, 0.66 and 0.43 for the volume, and 0.69 and 0.54 for sphericity, respectively. The SVM using texture features yielded significantly higher AUCs than univariate logistic regression models using morphological features (p = 0.001). CONCLUSION For the identification of metastatic lymph nodes from thyroid cancer on contrast-enhanced CT images, machine learning combined with texture analysis was superior to conventional diagnostic methods with the morphological parameters. IMPLICATIONS FOR PRACTICE Our findings suggest that in patients with thyroid cancer and suspected lymph node metastasis who undergo contrast-enhanced CT studies, machine learning using texture analysis is high diagnostic value for the identification of metastatic lymph nodes.
Collapse
Affiliation(s)
- T Masuda
- Department of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan; Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima, Japan.
| | - T Nakaura
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto 860-8556, Japan
| | - Y Funama
- Department of Medical Physics, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japan
| | - K Sugino
- Department of Surgery, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - T Sato
- Department of Diagnostic Radiology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - T Yoshiura
- Department of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - Y Baba
- Saitama Medical University International Medical Center, 1397-1, Yamane, Hidaka-City, Saitama-Pref 350-1298, Japan
| | - K Awai
- Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima, Japan
| |
Collapse
|
48
|
Masuda T, Funama Y, Nakaura T, Sato T, Muraoka Y, Okimoto T, Yamashita Y, Oku T, Matsumoto Y, Masuda S, Kiguchi M, Awai K. The combined application of the contrast-to-noise index and 80 kVp for cardiac CTA scanning before atrial fibrillation ablation reduces radiation dose exposure. Radiography (Lond) 2021; 27:840-846. [PMID: 33549491 DOI: 10.1016/j.radi.2021.01.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2020] [Revised: 12/26/2020] [Accepted: 01/13/2021] [Indexed: 11/27/2022]
Abstract
INTRODUCTION To compare the radiation dose, diagnostic accuracy, and the resultant ablation procedures using 80 and 120-kVp cardiac computed tomography angiography (CCTA) protocols with the same contrast-to-noise ratio in patients scheduled for atrial fibrillation (AF) ablation. METHODS This retrospective study was performed following institutional review board approval. We divided 140 consecutive patients who had undergone CCTA using a 64-MDCT scanner into two equal groups. Standard deviation (SD) of the CT number was set at 25 Hounsfield units (HU) for the 120-kVp protocol. To facilitate a reduction in radiation dose it was set at 40 HU for the 80 kVp protocol. We compared the two protocols with respect to the radiation dose, the diagnostic accuracy for detecting left atrial appendage (LAA) thrombi, matching for surface registration, and the resultant ablation procedures. RESULTS At 120 kVp, the dose length product (DLP) was 2.2 times that at 80 kVp (1269.0 vs 559.0 mGy cm, p < 0.01). The diagnostic accuracy for thrombus detection was 100% using both protocols. There was no difference between the two protocols with respect to matching for surface registration. The protocols did not differ with respect to the subsequent time required for the ablation procedures and the ablation fluoroscopy time, and the radiation dose (p = 0.54, 0.33, and 0.32, respectively). CONCLUSION For the same CNR, the DLP at 80 kVp (559.0 mGy cm) was 56% of that delivered at 120 kVp (1269.0 mGy cm). There was no reduction in diagnostic accuracy. IMPLICATIONS FOR PRACTICE Maintaining CNR allows for a reduction in the radiation dose without reducing the image quality.
Collapse
Affiliation(s)
- T Masuda
- Department of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima, 730-8655, Japan; Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima, Japan.
| | - Y Funama
- Department of Medical Physics, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japan
| | - T Nakaura
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto, 860-8556, Japan
| | - T Sato
- Department of Diagnostic Radiology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - Y Muraoka
- Department of Cardiovascular Internal Medicine, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - T Okimoto
- Department of Cardiovascular Internal Medicine, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - Y Yamashita
- Department of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima, 730-8655, Japan
| | - T Oku
- Department of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima, 730-8655, Japan
| | - Y Matsumoto
- Department of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima, 730-8655, Japan
| | - S Masuda
- Department of Radiological Technology, Kawamura Clinic, Otemachi, Naka-ku, Hiroshima, 730-0051, Japan
| | - M Kiguchi
- Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima, Japan
| | - K Awai
- Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima, Japan
| |
Collapse
|
49
|
Nonaka H, Masuda T, Nakaura T, Tahara M, Nitta T, Yoneyama M, Okano M, Morikawa Y, Sato T. Evaluating for systemic artery aneurysms using noncontrast magnetic resonance angiography in patients with Kawasaki disease: A report of two cases. Radiol Case Rep 2021; 16:621-627. [PMID: 33425086 PMCID: PMC7785888 DOI: 10.1016/j.radcr.2020.12.062] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2020] [Revised: 12/23/2020] [Accepted: 12/25/2020] [Indexed: 12/17/2022] Open
Abstract
Kawasaki disease (KD) involves coronary aneurysms and can infrequently cause systemic artery aneurysms (SAAs). Therefore, patients with KD should be evaluated for both coronary and systemic arterial aneurysms. This report describes 2 cases of SAA evaluated using the diastolic phase image of electrocardiogram-gated three-dimensional fast spin echo during noncontrast magnetic resonance angiography. The first case was a 1-year-old male who diagnosed with KD at 2 months of age. Multiple right axillary artery aneurysms measuring 6.0 mm and 2.5 mm and left axillary artery aneurysms measuring 12.0 mm, 4.0 mm, and 3.0 mm were observed by scanning for 94 seconds. The second case was a 13-year-old male who diagnosed with KD at 4 months of age, with a 7.0-mm right axillary artery aneurysm observed by scanning for 101 seconds. Electrocardiogram-gated three-dimensional fast spin echo in the diastolic phase can help evaluate SAA in patients with KD and does not require a prolonged scanning time or contrast medium.
Collapse
Affiliation(s)
- Haruki Nonaka
- Department of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - Takanori Masuda
- Department of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - Takeshi Nakaura
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto 860-8556, Japan
| | - Masahiro Tahara
- Department of Pediatric Cardiology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - Tetsuya Nitta
- Nitta Pediatric Clinic, Yokogawa-cho 3-9-14, Nishi-ku, Hiroshima 733-0011, Japan
| | - Masami Yoneyama
- Philips Japan, 2-13-37 Konan, Minato-ku, Tokyo 108-8507, Japan
| | - Mio Okano
- Department of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - Yuko Morikawa
- Department of Radiological Technology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - Tomoyasu Sato
- Department of Diagnostic Radiology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| |
Collapse
|
50
|
Ogawa Y, Naganuma A, Kudou T, Hoshino T, Ishii K, Kishi A, Shimoda C, Masuda T, Ogawa T, Ishihara H. Relationship between sarcopenia and length of hospital stay in patients with ulcerative colitis. Clin Nutr ESPEN 2020. [DOI: 10.1016/j.clnesp.2020.09.148] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|