1
|
Ren A, Yao M, Fang J, Dai Z, Li X, van der Meer W, Medema G, Rose JB, Liu G. Bacterial communities of planktonic bacteria and mature biofilm in service lines and premise plumbing of a Megacity: Composition, Diversity, and influencing factors. Environ Int 2024; 185:108538. [PMID: 38422875 DOI: 10.1016/j.envint.2024.108538] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/28/2023] [Revised: 02/14/2024] [Accepted: 02/26/2024] [Indexed: 03/02/2024]
Abstract
Although simulated studies have provided valuable knowledge regarding the communities of planktonic bacteria and biofilms, the lack of systematic field studies have hampered the understanding of microbiology in real-world service lines and premise plumbing. In this study, the bacterial communities of water and biofilm were explored, with a special focus on the lifetime development of biofilm communities and their key influencing factors. The 16S rRNA gene sequencing results showed that both the planktonic bacteria and biofilm were dominated by Proteobacteria. Among the 15,084 observed amplicon sequence variants (ASVs), the 33 core ASVs covered 72.8 %, while the 12 shared core ASVs accounted for 62.2 % of the total sequences. Remarkably, it was found that the species richness and diversity of biofilm communities correlated with pipe age. The relative abundance of ASV2 (f_Sphingomonadaceae) was lower for pipe ages 40-50 years (7.9 %) than for pipe ages 10-20 years (59.3 %), while the relative abundance of ASV10 (f_Hyphomonadaceae) was higher for pipe ages 40-50 years (19.5 %) than its presence at pipe ages 20-30 years (1.9 %). The community of the premise plumbing biofilm had significantly higher species richness and diversity than that of the service line, while the steel-plastics composite pipe interior lined with polyethylene (S-PE) harbored significantly more diverse biofilm than the galvanized steel pipes (S-Zn). Interestingly, S-PE was enriched with ASV27 (g_Mycobacterium), while S-Zn pipes were enriched with ASV13 (g_Pseudomonas). Moreover, the network analysis showed that five rare ASVs, not core ASVs, were keystone members in biofilm communities, indicating the importance of rare members in the function and stability of biofilm communities. This manuscript provides novel insights into real-world service lines and premise plumbing microbiology, regarding lifetime dynamics (pipe age 10-50 years), and the influences of pipe types (premise plumbing vs. service line) and pipe materials (S-Zn vs. S-PE).
Collapse
Affiliation(s)
- Anran Ren
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600 GA Delft, The Netherlands; University of Chinese Academy of Sciences, Beijing, China
| | - Mingchen Yao
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600 GA Delft, The Netherlands; University of Chinese Academy of Sciences, Beijing, China
| | - Jiaxing Fang
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; Science and Technology, University of Twente, P.O. Box 217, 7500AE Enschede, The Netherlands
| | - Zihan Dai
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Xiaoming Li
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing, China.
| | - Walter van der Meer
- Science and Technology, University of Twente, P.O. Box 217, 7500AE Enschede, The Netherlands; Oasen Drinkwater, PO Box 122, 2800 AC, Gouda, The Netherlands
| | - Gertjan Medema
- Oasen Drinkwater, PO Box 122, 2800 AC, Gouda, The Netherlands; KWR Watercycle Research Institute, P.O. Box 1072, 3430 BB Nieuwegein, The Netherlands; Department of Fisheries and Wildlife, Michigan State University, East Lansing, MI 48823, USA
| | - Joan B Rose
- Department of Fisheries and Wildlife, Michigan State University, East Lansing, MI 48823, USA
| | - Gang Liu
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600 GA Delft, The Netherlands; University of Chinese Academy of Sciences, Beijing, China.
| |
Collapse
|
2
|
Wang X, Xu Y, Ou Q, Chen W, van der Meer W, Liu G. Adsorption characteristics and mechanisms of water-soluble polymers (PVP and PEG) on kaolin and montmorillonite minerals. J Hazard Mater 2024; 466:133592. [PMID: 38290331 DOI: 10.1016/j.jhazmat.2024.133592] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2023] [Revised: 01/18/2024] [Accepted: 01/20/2024] [Indexed: 02/01/2024]
Abstract
The excessive use and accumulation of water-soluble polymers (WSPs, known as "liquid plastics") in the environment can pose potential risks to both ecosystems and human health, but the environmental fate of WSPs remains unclear. Here, the adsorption behavior of WSPs with different molecular weight on kaolinite (Kaol) and montmorillonite (Mt) were examined. The results showed that the adsorption of PEG and PVP on minerals were controlled by hydrogen bond and van der Waals force. The Fourier transform infrared (FTIR) spectra and two-dimensional correlation spectroscopy (2D-COS) analysis revealed that there were interactions between the Al-O and Si-O groups of the minerals and the polar O- or N-containing functional groups as well as the alkyl groups of PEG and PVP. The adsorption characteristics of WSPs were closely related to their molecular weight and the pore size of minerals. Due to the relatively large mesopore size of Kaol, both PEG and PVP were absorbed into inner spaces, for which the adsorption capacity increased with molecular weight of the polymers. For Mt, all types of PEG could enter its micropores, while PVP with larger molecular weights appeared to be confined externally, leading to a decrease in the adsorption capacity of PVP with increasing molecular weight. The findings of this study provide a theoretical basis for scientific evaluation of environmental processes of WSPs.
Collapse
Affiliation(s)
- Xintu Wang
- The Guangxi Key Laboratory of Theory and Technology for Environmental Pollution Control, Guilin University of Technology, Guilin 541006, China; Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
| | - Yanghui Xu
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; Section of Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, Stevinweg 1, 2628 CN Delft, the Netherlands
| | - Qin Ou
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; Section of Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, Stevinweg 1, 2628 CN Delft, the Netherlands
| | - Wenwen Chen
- The Guangxi Key Laboratory of Theory and Technology for Environmental Pollution Control, Guilin University of Technology, Guilin 541006, China
| | - Walter van der Meer
- Science and Technology Faculty, Twente University, Enschede 7500AE, the Netherlands; Oasen Drinkwater, Gouda 2800 AC, the Netherlands
| | - Gang Liu
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; Section of Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, Stevinweg 1, 2628 CN Delft, the Netherlands; University of Chinese Academy of Sciences, Beijing, China.
| |
Collapse
|
3
|
Fang J, Dai Z, Li X, van der Hoek JP, Savic D, Medema G, van der Meer W, Liu G. Service-lines as major contributor to water quality deterioration at customer ends. Water Res 2023; 241:120143. [PMID: 37276656 DOI: 10.1016/j.watres.2023.120143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Revised: 05/16/2023] [Accepted: 05/28/2023] [Indexed: 06/07/2023]
Abstract
Biofilm detachment contributes to water quality deterioration. However, the contributions of biofilm detachment from different pipes have not been quantified or compared. Following the introduction of partial reverse osmosis (RO) in drinking water production, this study analyzed particles at customers' ends and tracked their origins to water distribution mains and service lines. For doing so, filter bags were installed in front of water meters to capture upstream detached particles, while biofilm from water main and service line were sampled by cutting pipe specimens. The results showed that elemental concentrations of the biofilm in mains were higher than those of service lines (54.3-268.5 vs. 27.1-44.4 μg/cm2), both dominated by Ca. Differently, filter bags were dominated by Fe/Mn (77.5-98.1%). After introducing RO, Ca significantly decreased in biofilms of mains but not service lines, but the released Fe/Mn rather than Ca arrived at customers' ends. The ATP concentrations of service lines were higher than mains, which decreased on mains but increased in service lines after introducing RO. For the core ASVs, 13/24 were shared by service lines (17), mains (21), and filter bags (17), which were assigned mainly to Nitrospira spp., Methylomagnum spp., Methylocytis spp., and IheB2-23 spp. According to source tracking results, service lines contributed more than mains to the particulate material collected by filter bags (57.6 ± 13.2% vs. 13.0 ± 11.6%). To the best of our knowledge, the present study provides the first evidence of service lines' direct and quantitative contributions to potential water quality deterioration at customers' ends. This highlights the need for the appropriate management of long-neglected service line pipes, e.g., regarding material selection, length optimization, and proper regulation.
Collapse
Affiliation(s)
- Jiaxing Fang
- Key Lab of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, 100085, Beijing, PR China; Membrane Science and Technology, Faculty of Science and Technology, University of Twente, P.O. Box 217, 7500, AE, Enschede, the Netherlands; Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600, GA, Delft, the Netherlands
| | - Zihan Dai
- Key Lab of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, 100085, Beijing, PR China
| | - Xiaoming Li
- Key Lab of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, 100085, Beijing, PR China
| | - Jan Peter van der Hoek
- Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600, GA, Delft, the Netherlands; Waternet, P.O. Box 94370, 1090, GJ Amsterdam, the Netherlands
| | - Dragan Savic
- KWR Water Research Institute, P.O. Box 1072, 3430, BB, Nieuwegein, the Netherlands; Centre for Water Systems, University of Exeter, Exeter EX4 4QF, United Kingdom; University of Belgrade, Faculty of Civil Engineering, Department for Hydraulic and environmental engineering, Bulevar kralja Aleksandra 73, Belgrade, Serbia
| | - Gertjan Medema
- Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600, GA, Delft, the Netherlands; KWR Water Research Institute, P.O. Box 1072, 3430, BB, Nieuwegein, the Netherlands; Department of Fisheries and Wildlife, Michigan State University, East Lansing, MI, 48823, USA
| | - Walter van der Meer
- Membrane Science and Technology, Faculty of Science and Technology, University of Twente, P.O. Box 217, 7500, AE, Enschede, the Netherlands; Oasen Water Company, PO BOX 122, 2800, AC, Gouda, the Netherlands
| | - Gang Liu
- Key Lab of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, 100085, Beijing, PR China; Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600, GA, Delft, the Netherlands.
| |
Collapse
|
4
|
Yao M, Zhang Y, Dai Z, Ren A, Fang J, Li X, van der Meer W, Medema G, Rose JB, Liu G. Building water quality deterioration during water supply restoration after interruption: Influences of premise plumbing configuration. Water Res 2023; 241:120149. [PMID: 37270942 DOI: 10.1016/j.watres.2023.120149] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/26/2023] [Revised: 05/26/2023] [Accepted: 05/28/2023] [Indexed: 06/06/2023]
Abstract
Premise plumbing plays an essential role in determining the final quality of drinking water consumed by customers. However, little is known about the influences of plumbing configuration on water quality changes. This study selected parallel premise plumbing in the same building with different configurations, i.e., laboratory and toilet plumbing. Water quality deteriorations induced by premise plumbing under regular and interrupted water supply were investigated. The results showed that most of the water quality parameters did not vary under regular supply, except Zn, which was significantly increased by laboratory plumbing (78.2 to 260.7 µg/l). For the bacterial community, the Chao1 index was significantly increased by both plumbing types to a similar level (52 to 104). Laboratory plumbing significantly changed the bacterial community, but toilet plumbing did not. Remarkably, water supply interruption/restoration led to serious water quality deterioration in both plumbing types but resulted in different changes. Physiochemically, discoloration was observed only in laboratory plumbing, along with sharp increases in Mn and Zn. Microbiologically, the increase in ATP was sharper in toilet plumbing than in laboratory plumbing. Some opportunistic pathogen-containing genera, e.g., Legionella spp. and Pseudomonas spp., were present in both plumbing types but only in disturbed samples. This study highlighted the esthetic, chemical, and microbiological risks associated with premise plumbing, for which system configuration plays an important role. Attention should be given to optimizing premise plumbing design for managing building water quality.
Collapse
Affiliation(s)
- Mingchen Yao
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing, China; Sanitary engineering, Department of Water management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, Delft, GA 2600, the Netherlands
| | - Yue Zhang
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing, China
| | - Zihan Dai
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing, China
| | - Anran Ren
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing, China
| | - Jiaxing Fang
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; Membrane Science and Technology, Faculty of Science and Technology, University of Twente, P.O. Box 217, Enschede 7500AE, the Netherlands
| | - Xiaoming Li
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing, China
| | - Walter van der Meer
- Membrane Science and Technology, Faculty of Science and Technology, University of Twente, P.O. Box 217, Enschede 7500AE, the Netherlands; Oasen Drinkwater, PO BOX 122, Gouda, AC 2800, the Netherlands
| | - Gertjan Medema
- Sanitary engineering, Department of Water management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, Delft, GA 2600, the Netherlands; KWR Watercycle Research Institute, P.O. Box 1072, Nieuwegein 3430 BB, the Netherlands; Department of Fisheries and Wildlife, Michigan State University, East Lansing, MI 48823, United States of America
| | - Joan B Rose
- Department of Fisheries and Wildlife, Michigan State University, East Lansing, MI 48823, United States of America
| | - Gang Liu
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing, China.
| |
Collapse
|
5
|
Chen L, Li X, van der Meer W, Medema G, Liu G. Capturing and tracing the spatiotemporal variations of planktonic and particle-associated bacteria in an unchlorinated drinking water distribution system. Water Res 2022; 219:118589. [PMID: 35597222 DOI: 10.1016/j.watres.2022.118589] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Revised: 05/05/2022] [Accepted: 05/10/2022] [Indexed: 06/15/2023]
Abstract
The aperiodic changes in the quantity and community of planktonic and particle-associated bacteria have hampered the understanding and management of microbiological water quality in drinking water distribution systems. In this study, online sampling was combined with the microbial fingerprint-based SourceTracker2 to capture and trace the spatiotemporal variations in planktonic and particle-associated bacteria in an unchlorinated distribution system. The results showed that spatially, the particle load significantly increased, while in contrast, the quantity of particle-associated bacteria decreased sharply from the treatment plant to the distribution network. Similar to the trend of particle-associated bacterial diversity, the number of observed OTUs first slightly decreased from the treatment plant to the transportation network and then sharply increased from the transportation network to the distribution network. The SourceTracker2 results revealed that the contribution of particle-associated bacteria from the treatment plant decreased along the distribution distance. The spatial results indicate the dominant role of sedimentation of particles from the treatment plant, while the observed increases in particles and the associated bacteria mainly originated from the distribution network, which were confirmed directly by the increased contributions of loose deposits and biofilm. Temporally, the daily peaks of particle-associated bacterial quantity, observed OTU number, and contributions of loose deposits and biofilms were captured during water demand peaks (e.g., 18-21 h). The temporal results reveal clear linkages between the distribution system harboring bacteria (e.g., within loose deposits and biofilms) and the planktonic and particle-associated bacteria flowing through the distribution system, which are dynamically connected and interact. This study highlights that the spatiotemporal variations in planktonic and particle-associated bacteria are valuable and unneglectable for the widely on-going sampling campaigns required by water quality regulations and/or drinking water microbiological studies.
Collapse
Affiliation(s)
- Lihua Chen
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, P.R China; Department of Water Management, Sanitary Engineering, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, Delft 2600 GA, the Netherlands
| | - Xuan Li
- Department of Water Management, Sanitary Engineering, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, Delft 2600 GA, the Netherlands
| | - Walter van der Meer
- Membrane Science and Technology, University of Twente, Drienerlolaan 5, Enschede 7522 NB, the Netherlands; Oasen Drinkwater, Nieuwe Gouwe O.Z. 3, Gouda 2801 SB, the Netherlands
| | - Gertjan Medema
- Department of Water Management, Sanitary Engineering, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, Delft 2600 GA, the Netherlands; KWR Water Research Institute, P.O. Box 1072, Nieuwegein 3430 BB, the Netherlands; Michigan State University, 1405 S Harrison Rd, East-Lansing, MI 48823, United States
| | - Gang Liu
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, P.R China; Department of Water Management, Sanitary Engineering, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, Delft 2600 GA, the Netherlands.
| |
Collapse
|
6
|
Pappaterra M, Xu P, van der Meer W, Faria JA, Fernandez Rivas D. Cavitation intensifying bags improve ultrasonic advanced oxidation with Pd/Al 2O 3 catalyst. Ultrason Sonochem 2021; 70:105324. [PMID: 32947211 PMCID: PMC7786540 DOI: 10.1016/j.ultsonch.2020.105324] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/24/2020] [Revised: 08/26/2020] [Accepted: 08/27/2020] [Indexed: 06/11/2023]
Abstract
Advanced oxidation processes can potentially eliminate organic contaminants from industrial waste streams as well as persistent pharmaceutical components in drinking water. We explore for the first time the utilization of Cavitation Intensifying Bags (CIB) in combination with Pd/Al2O3 catalyst as possible advanced oxidation technology for wastewater streams, oxidizing terephthalic acid (TA) to 2-hydroxyterephthalic acid (HTA). The detailed characterization of this novel reaction system reveals that, during sonication, the presence of surface pits of the CIB improves the reproducibility and thus the control of the sonication process, when compared to oxidation in non-pitted bags. Detailed reaction kinetics shows that in the CIB reactor the reaction order to TA is zero, which is attributed to the large excess of TA in the system. The rate of HTA formation increased ten-fold from ~0.01 μM*min-1 during sonication in the CIB, to ~0.10 μM*min-1 for CIB in the presence of the Pd/Al2O3 catalyst. This enhancement was ascribed to a combination of improved mass transport, the creation of thermal gradients, and Pd/Al2O3 catalyst near the cavitating bubbles. Further analysis of the kinetics of HTA formation on Pd/Al2O3 indicated that initially the reaction underwent through an induction period of 20 min, where the HTA concentration was ~0.3 μM. After this, the reaction rate increased reaching HTA concentrations ~6 μM after 40 min. This behavior resembled that observed during oxidation of hydrocarbons on metal catalysts, where the slow rate formation of hydroperoxides on the metal surface is followed by rapid product formation upon reaching a critical concentration. Finally, a global analysis using the Intensification Factor (IF) reveals that CIB in combination with the Pd/Al2O3 catalyst is a desirable option for the oxidation of TA when considering increased oxidation rates and costs.
Collapse
Affiliation(s)
- Maria Pappaterra
- Mesoscale Chemical Systems Group, Faculty of Science and Technology, MESA+ Institute for Nanotechnology, and University of Twente, PO Box 217, 7500 AE Enschede, The Netherlands; Delft University of Technology, Delft, The Netherlands
| | - Pengyu Xu
- Catalytic Processes and Materials Group, Faculty of Science and Technology, MESA+ Institute for Nanotechnology, University of Twente, PO Box 217, 7500 AE Enschede, The Netherlands
| | - Walter van der Meer
- Oasen Water Company, PO BOX 122, 2800 AC Gouda, The Netherlands; Membranes Science and Technology, Faculty of Science and Technology, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands
| | - Jimmy A Faria
- Catalytic Processes and Materials Group, Faculty of Science and Technology, MESA+ Institute for Nanotechnology, University of Twente, PO Box 217, 7500 AE Enschede, The Netherlands.
| | - David Fernandez Rivas
- Mesoscale Chemical Systems Group, Faculty of Science and Technology, MESA+ Institute for Nanotechnology, and University of Twente, PO Box 217, 7500 AE Enschede, The Netherlands.
| |
Collapse
|
7
|
Sousi M, Liu G, Salinas-Rodriguez SG, Chen L, Dusseldorp J, Wessels P, Schippers JC, Kennedy MD, van der Meer W. Multi-parametric assessment of biological stability of drinking water produced from groundwater: Reverse osmosis vs. conventional treatment. Water Res 2020; 186:116317. [PMID: 32841931 DOI: 10.1016/j.watres.2020.116317] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/22/2020] [Revised: 08/16/2020] [Accepted: 08/17/2020] [Indexed: 06/11/2023]
Abstract
Although water produced by reverse osmosis (RO) filtration has low bacterial growth potential (BGP), post-treatment of RO permeate, which is necessary prior to distribution and human consumption, needs to be examined because of the potential re-introduction of nutrients/contaminants. In this study, drinking water produced from anaerobic groundwater by RO and post-treatment (ion exchange, calcite contactors, and aeration) was compared with that produced by conventional treatment comprising (dry) sand filtration, pellet softening, rapid sand filtration, activated carbon filtration, and UV disinfection. The multi-parametric assessment of biological stability included bacterial quantification, nutrient concentration and composition as well as bacterial community composition and diversity. Results showed that RO permeate remineralised in the laboratory has an extremely low BGP (50 ± 12 × 103 ICC/mL), which increased to 130 ± 10 × 103 ICC/mL after site post-treatment. Despite the negative impact of post-treatment, the BGP of the finished RO-treated water was >75% lower than that of conventionally treated water. Organic carbon limited bacterial growth in both RO-treated and conventionally treated waters. The increased BGP in RO-treated water was caused by the re-introduction of nutrients during post-treatment. Similarly, OTUs introduced during post-treatment, assigned to the phyla of Proteobacteria and Bacteroidetes (75-85%), were not present in the source groundwater. Conversely, conventionally treated water shared some OTUs with the source groundwater. It is clear that RO-based treatment achieved an extremely low BGP, which can be further improved by optimising post-treatment, such as using high purity calcite. The multi-parametric approach adopted in this study can offer insights into growth characteristics including limiting nutrients (why) and dominating genera growing (who), which is essential to manage microbiological water quality in water treatment and distribution systems.
Collapse
Affiliation(s)
- Mohaned Sousi
- Department of Environmental Engineering and Water Technology, IHE Delft Institute for Water Education, Westvest 7, AX Delft 2611, the Netherlands; Faculty of Science and Technology, University of Twente, Drienerlolaan 5, NB Enschede 7522, the Netherlands
| | - Gang Liu
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, PR China; Department of Water Management, Faculty of Civil Engineering and Geoscience, Delft University of Technology, Mekelweg 2, CD Delft 2628, the Netherlands.
| | - Sergio G Salinas-Rodriguez
- Department of Environmental Engineering and Water Technology, IHE Delft Institute for Water Education, Westvest 7, AX Delft 2611, the Netherlands
| | - Lihua Chen
- Department of Water Management, Faculty of Civil Engineering and Geoscience, Delft University of Technology, Mekelweg 2, CD Delft 2628, the Netherlands
| | - Jos Dusseldorp
- Oasen Drinkwater, Nieuwe Gouwe O.Z. 3, SB Gouda 2801, the Netherlands
| | - Peter Wessels
- Oasen Drinkwater, Nieuwe Gouwe O.Z. 3, SB Gouda 2801, the Netherlands
| | - Jan C Schippers
- Department of Environmental Engineering and Water Technology, IHE Delft Institute for Water Education, Westvest 7, AX Delft 2611, the Netherlands
| | - Maria D Kennedy
- Department of Environmental Engineering and Water Technology, IHE Delft Institute for Water Education, Westvest 7, AX Delft 2611, the Netherlands; Department of Water Management, Faculty of Civil Engineering and Geoscience, Delft University of Technology, Mekelweg 2, CD Delft 2628, the Netherlands
| | - Walter van der Meer
- Faculty of Science and Technology, University of Twente, Drienerlolaan 5, NB Enschede 7522, the Netherlands; Oasen Drinkwater, Nieuwe Gouwe O.Z. 3, SB Gouda 2801, the Netherlands
| |
Collapse
|
8
|
Liu G, Zhang Y, Liu X, Hammes F, Liu WT, Medema G, Wessels P, van der Meer W. 360-Degree Distribution of Biofilm Quantity and Community in an Operational Unchlorinated Drinking Water Distribution Pipe. Environ Sci Technol 2020; 54:5619-5628. [PMID: 32259432 PMCID: PMC7203839 DOI: 10.1021/acs.est.9b06603] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
In the present study, triplicate rings of 360° pipe surfaces of an operational drinking water distribution pipe were swabbed. Each ring was equally divided into 16 parts for swabbing. The collected swabs were grouped into 3 sections and compared with the biofilm samples sampled by sonication of specimens from the same pipe. The results showed that the biofilm is unevenly distributed over the 16 parts and the 3 sections of the pipe surface. Both the active biomass and the number of observed OTUs increased as the measurements proceeded from the top to the bottom of the pipe. The bacterial community was dominated in all sections by Proteobacteria. At the genus level, Nitrospira spp., Terrimonas spp., and Hyphomicrobium spp. were dominant in all sections. Gaiella spp. and Vicinamibacter spp. dominated in S-I, Blastopirellula spp. and Pirellula spp. dominated in S-II, while Holophaga spp. and Phaeodactylibacter spp. dominated in S-III. When swabbing and pipe specimen sonication were compared, the results showed that the sampling strategy significantly influences the obtained biofilm bacterial community. A consistent multisectional swabbing strategy is proposed for future biofilm sampling; it involves collecting swabs from all sections and comparing the swabs from the same position/section across locations.
Collapse
Affiliation(s)
- Gang Liu
- Key
Laboratory of Drinking Water Science and Technology, Research Centre
for Eco-Environmental Sciences, Chinese
Academy of Sciences, Beijing, 100085, P. R. China
- Oasen
Drinkwater, P.O. Box
122, 2801SB, Gouda, The Netherlands
- Sanitary
Engineering, Department of Water Management, Faculty of Civil Engineering
and Geosciences, Delft University of Technology, P.O. Box 5048, 2600GA Delft, The Netherlands
- Phone: 0086 17600879707; e-mail: ,
| | - Ya Zhang
- Department
of Civil and Environmental Engineering, University of Illinois at Urbana−Champaign, 205 North Mathews Avenue, Urbana, Illinois 61801, United States
| | - Xinlei Liu
- Catalysis
Engineering, Chemical Engineering Department, Delft University of Technology, van der Maasweg 9, 2629 HZ Delft, The Netherlands
| | - Frederik Hammes
- Eawag,
Swiss
Federal Institute of Aquatic Science and Technology, Dübendorf, Switzerland
| | - Wen-Tso Liu
- Department
of Civil and Environmental Engineering, University of Illinois at Urbana−Champaign, 205 North Mathews Avenue, Urbana, Illinois 61801, United States
| | - Gertjan Medema
- Sanitary
Engineering, Department of Water Management, Faculty of Civil Engineering
and Geosciences, Delft University of Technology, P.O. Box 5048, 2600GA Delft, The Netherlands
- KWR
Watercycle Research Institute, P.O. Box 1072, 3430 BB Nieuwegein, The Netherlands
| | - Peter Wessels
- Oasen
Drinkwater, P.O. Box
122, 2801SB, Gouda, The Netherlands
| | - Walter van der Meer
- Oasen
Drinkwater, P.O. Box
122, 2801SB, Gouda, The Netherlands
- Science
and Technology, University of Twente, P.O. Box 217, 7500AE Enschede, The Netherlands
| |
Collapse
|
9
|
Sousi M, Salinas-Rodriguez SG, Liu G, Schippers JC, Kennedy MD, van der Meer W. Measuring Bacterial Growth Potential of Ultra-Low Nutrient Drinking Water Produced by Reverse Osmosis: Effect of Sample Pre-treatment and Bacterial Inoculum. Front Microbiol 2020; 11:791. [PMID: 32411118 PMCID: PMC7201026 DOI: 10.3389/fmicb.2020.00791] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2019] [Accepted: 04/02/2020] [Indexed: 12/20/2022] Open
Abstract
Measuring bacterial growth potential (BGP) involves sample pre-treatment and inoculation, both of which may introduce contaminants in ultra-low nutrient water (e.g., remineralized RO permeate). Pasteurization pre-treatment may lead to denaturing of nutrients, and membrane filtration may leach/remove nutrients into/from water samples. Inoculating remineralized RO permeate samples with natural bacteria from conventional drinking water leads to undesired nutrient addition, which could be avoided by using the remineralized RO permeate itself as inoculum. Therefore, this study examined the effect of pasteurization and membrane filtration on the BGP of remineralized RO permeate. In addition, the possibility of using bacteria from remineralized RO permeate as inoculum was investigated by evaluating their ability to utilize organic carbon that is readily available (acetate, glucose) or complex (laminarin, gelatin, and natural dissolved organic carbon), as compared with bacteria from conventional drinking water. The results showed that membrane filtration pre-treatment increased (140-320%) the BGP of remineralized RO permeate despite the extensive soaking and flushing of filters (>350 h), whereas no effect was observed on the BGP of conventional drinking water owing to its high nutrient content. Pasteurization pre-treatment had insignificant effects on the BGP of both water types. Remineralized RO permeate bacteria showed limitations in utilizing complex organic carbon compared with bacteria from conventional drinking water. In conclusion, the BGP bioassay for ultra-low nutrient water (e.g., remineralized RO permeate) should consider pasteurization pre-treatment. However, an inoculum comprising bacteria from remineralized RO permeate is not recommended as the bacterial consortium was shown to be limited in terms of the compounds they could utilize for growth.
Collapse
Affiliation(s)
- Mohaned Sousi
- Department of Environmental Engineering and Water Technology, IHE Delft Institute for Water Education, Delft, Netherlands
- Faculty of Science and Technology, University of Twente, Enschede, Netherlands
| | - Sergio G. Salinas-Rodriguez
- Department of Environmental Engineering and Water Technology, IHE Delft Institute for Water Education, Delft, Netherlands
| | - Gang Liu
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, China
- Department of Water Management, Faculty of Civil Engineering and Geoscience, Delft University of Technology, Delft, Netherlands
| | - Jan C. Schippers
- Department of Environmental Engineering and Water Technology, IHE Delft Institute for Water Education, Delft, Netherlands
| | - Maria D. Kennedy
- Department of Environmental Engineering and Water Technology, IHE Delft Institute for Water Education, Delft, Netherlands
- Department of Water Management, Faculty of Civil Engineering and Geoscience, Delft University of Technology, Delft, Netherlands
| | - Walter van der Meer
- Faculty of Science and Technology, University of Twente, Enschede, Netherlands
- Oasen Drinkwater, Gouda, Netherlands
| |
Collapse
|
10
|
Chen L, Ling F, Bakker G, Liu WT, Medema G, van der Meer W, Liu G. Assessing the transition effects in a drinking water distribution system caused by changing supply water quality: an indirect approach by characterizing suspended solids. Water Res 2020; 168:115159. [PMID: 31614234 DOI: 10.1016/j.watres.2019.115159] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/25/2019] [Revised: 10/03/2019] [Accepted: 10/04/2019] [Indexed: 05/16/2023]
Abstract
Worldwide, it is common that the drinking water distribution systems (DWDSs) may be subjected to changes of supply water quality due to the needs of upgrading the treatment processes or switching the source water. However, the potential impacts of quality changed supply water on the stabilized ecological niches within DWDSs and the associated water quality deterioration risks were poorly documented. In the present study, such transition effects caused by changing the supply water quality that resulted from destabilization of biofilm and loose deposits in DWDS were investigated by analyzing the physiochemical and microbiological characteristics of suspended particles before (T0), during (T3-weeks) and after upgrading the treatments (T6-months) in an unchlorinated DWDS in the Netherlands. Our results demonstrated that after 6 months' time the upgraded treatments significantly improved the water quality. Remarkably, water quality deterioration was observed at the initial stage when the quality-improved treated water distributed into the network at T3-weeks, observed as a spike of total suspended solids (TSS, 50-260%), active biomass (ATP, 95-230%) and inorganic elements (e.g. Mn, 130-250%). Furthermore, pyrosequencing results revealed sharp differences in microbial community composition and structure for the bacteria associated with suspended particles between T0 and T3-weeks, which re-stabilized after 6 months at T6-months. The successful capture of transition effects was especially confirmed by the domination of Nitrospira spp. and Polaromonas spp. in the distribution system at T3-weeks, which were detected at rather low relative abundance at treatment plant. Though the transitional effects were captured, this study shows that the introduction of softening and additional filtration did not have an effect on the water quality for the consumer which improved considerably after 6-months' period. The methodology of monitoring suspended particles with MuPFiSs and additional analysis is capable of detecting transitional effects by monitoring the dynamics of suspended particles and its physiochemical and microbiological composition.
Collapse
Affiliation(s)
- Lihua Chen
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, PR China; Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600, GA, Delft, the Netherlands
| | - Fangqiong Ling
- Department of Energy, Environmental and Chemical Engineering, School of Engineering and Applied Science, Washington University in St. Louis, St. Louis, Missouri, 63130, USA
| | - Geo Bakker
- Vitens N.V., P.O. Box 1205, 8001, BE, Zwolle, the Netherlands
| | - Wen-Tso Liu
- Department of Civil and Environmental Engineering, University of Illinois Urbana-Champaign, 205 N. Mathews Ave., Urbana, IL, 61801, USA
| | - Gertjan Medema
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, PR China; KWR Watercycle Research Institute, P.O. Box 1072, 3430, BB, Nieuwegein, the Netherlands
| | - Walter van der Meer
- Oasen Water Company, PO BOX 122, 2800, AC, Gouda, the Netherlands; Science and Technology, University of Twente, P.O. Box 217, 7500, AE, Enschede, the Netherlands
| | - Gang Liu
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, PR China; Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600, GA, Delft, the Netherlands.
| |
Collapse
|
11
|
Vaudevire E, Radmanesh F, Kolkman A, Vughs D, Cornelissen E, Post J, van der Meer W. Fate and removal of trace pollutants from an anion exchange spent brine during the recovery process of natural organic matter and salts. Water Res 2019; 154:34-44. [PMID: 30771705 DOI: 10.1016/j.watres.2019.01.042] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/13/2018] [Revised: 12/21/2018] [Accepted: 01/28/2019] [Indexed: 06/09/2023]
Abstract
The results of this sampling campaign on pilot scale processes aim to evaluate the occurrence and behavior of trace organic micro-pollutants and metal elements during anion exchange treatment of surface water and the subsequent treatment of generated spent brine with two types of electrodialysis membrane pairs. This knowledge is relevant to assess the quality and reusability of secondary products created during brine treatment; specifically the excess of sodium chloride to be recycled onsite and the natural organic matter, mostly consisting of humic substances, which find multiple applications in the agricultural industry. This study highlights that (1) the attachment mechanism of organic micro-pollutants to anion exchange resin occurs through electrostatic interaction and the subsequent transfer through ion exchange membranes is restricted by size exclusion; and (2) the complexation of trace metals compounds with the natural organic matter partly explains their removal by anion exchange. Complexes remain stable during treatment of the brine with electrodialysis.
Collapse
Affiliation(s)
- Elisabeth Vaudevire
- PWN Technologies, Dijkweg 1, 1916HA, Andijk, the Netherlands; Wetsus, European Centre of Excellence for Sustainable Water Technology, Oostergoweg 9, 8911 MA, Leeuwarden, the Netherlands; Department of Biotechnologies, TU Delft, Van der Maasweg 9, 2629 HZ, Delft, the Netherlands.
| | - Farzaneh Radmanesh
- University of Twente, Faculty of Science and Technology, De Horst 2, 7522LW, Enschede, the Netherlands
| | - Annemieke Kolkman
- KWR Water Cycle Research Institute, Groningenhaven 7, 3433 PE, Nieuwegein, the Netherlands
| | - Dennis Vughs
- KWR Water Cycle Research Institute, Groningenhaven 7, 3433 PE, Nieuwegein, the Netherlands
| | - Emile Cornelissen
- KWR Water Cycle Research Institute, Groningenhaven 7, 3433 PE, Nieuwegein, the Netherlands; Particle and Interfacial Technology Group, Ghent University, Coupure Links 653, B-9000, Ghent, Belgium; Singapore Membrane Technology Centre, Nanyang Environment and Water Research Institute, Nanyang Technological University, Singapore, 637141, Singapore
| | - Jan Post
- Wetsus, European Centre of Excellence for Sustainable Water Technology, Oostergoweg 9, 8911 MA, Leeuwarden, the Netherlands
| | - Walter van der Meer
- University of Twente, Faculty of Science and Technology, De Horst 2, 7522LW, Enschede, the Netherlands; Oasen NV, Nieuwe Gouwe O.Z. 3, 2801 SB, Gouda, the Netherlands
| |
Collapse
|
12
|
Liu R, Guo T, Ma M, Yan M, Qi J, Hu C, Liu G, Liu H, Qu J, van der Meer W. Preferential binding between intracellular organic matters and Al 13 polymer to enhance coagulation performance. J Environ Sci (China) 2019; 76:1-11. [PMID: 30528000 DOI: 10.1016/j.jes.2018.05.011] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2017] [Revised: 05/12/2018] [Accepted: 05/14/2018] [Indexed: 06/09/2023]
Abstract
Coagulation is the best available method for removing intracellular organic matter (IOM), which is released from algae cells and is an important precursor to disinfection by-products in drinking water treatment. To gain insight into the best strategy to optimize IOM removal, the coagulation performance of two Al salts, i.e., aluminum chloride (AlCl3) and polyaluminum chloride (PACl, containing 81.2% Al13), was investigated to illuminate the effect of Al species distribution on IOM removal. PACl showed better removal efficiency than AlCl3 with regard to the removal of turbidity and dissolved organic carbon (DOC), owing to the higher charge neutralization effect and greater stability of pre-formed Al13 species. High pressure size exclusion chromatography analysis indicated that the superiority of PACl in DOC removal could be ascribed to the higher binding affinity between Al13 polymer and the low and medium molecular weight (MW) fractions of IOM. The results of differential log-transformed absorbance at 254 and 350 nm indicated more significant formation of complexes between AlCl3 and IOM, which benefits the removal of tryptophan-like proteins thereafter. Additionally, PACl showed more significant superiority compared to AlCl3 in the removal of <5 kDa and hydrophilic fractions, which are widely viewed as the most difficult to remove by coagulation. This study provides insight into the interactions between Al species and IOM, and advances the optimization of coagulation for the removal of IOM in eutrophic water.
Collapse
Affiliation(s)
- Ruiping Liu
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Tingting Guo
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; Beijing University of Technology, Beijing 100124, China
| | - Min Ma
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; Beijing Waterworks Group, Beijing 100031, China
| | - Mingquan Yan
- Department of Environmental Engineering, Peking University, Beijing 100871, China
| | - Jing Qi
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
| | - Chengzhi Hu
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing 100049, China.
| | - Gang Liu
- Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, 2600GA Delft, the Netherlands
| | - Huijuan Liu
- University of Chinese Academy of Sciences, Beijing 100049, China; State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
| | - Jiuhui Qu
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Walter van der Meer
- Science and Technology, University of Twente, 7500AE Enschede, the Netherlands
| |
Collapse
|
13
|
Albergamo V, Blankert B, Cornelissen ER, Hofs B, Knibbe WJ, van der Meer W, de Voogt P. Removal of polar organic micropollutants by pilot-scale reverse osmosis drinking water treatment. Water Res 2019; 148:535-545. [PMID: 30414537 DOI: 10.1016/j.watres.2018.09.029] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2018] [Revised: 09/10/2018] [Accepted: 09/15/2018] [Indexed: 05/22/2023]
Abstract
The robustness of reverse osmosis (RO) against polar organic micropollutants (MPs) was investigated in pilot-scale drinking water treatment. Experiments were carried in hypoxic conditions to treat a raw anaerobic riverbank filtrate spiked with a mixture of thirty model compounds. The chemicals were selected from scientific literature data based on their relevance for the quality of freshwater systems, RO permeate and drinking water. MPs passage and the influence of permeate flux were evaluated with a typical low-pressure RO membrane and quantified by liquid chromatography coupled to high-resolution mass spectrometry. A strong inverse correlation between size and passage of neutral hydrophilic compounds was observed. This correlation was weaker for moderately hydrophobic MPs. Anionic MPs displayed nearly no passage due to electrostatic repulsion with the negatively charged membrane surface, whereas breakthrough of small cationic MPs could be observed. The passage figures observed for the investigated set of MPs ranged from less than 1%-25%. Statistical analysis was performed to evaluate the relationship between physicochemical properties and passage. The effects of permeate flux were more pronounced for small neutral MPs, which displayed a higher passage after a pressure drop.
Collapse
Affiliation(s)
- Vittorio Albergamo
- Institute for Biodiversity and Ecosystem Dynamics, University of Amsterdam, Science Park 904, 1098 XH Amsterdam, The Netherlands.
| | - Bastiaan Blankert
- Oasen Drinking Water Company, Postbus 122, 2800 AC Gouda, The Netherlands
| | - Emile R Cornelissen
- KWR Watercycle Research Institute, Groningenhaven 7, 3433 PE Nieuwegein, The Netherlands; Singapore Membrane Technology Centre, Nanyang Environment and Water Research Institute, Nanyang Technological University, Singapore 637141, Singapore; Particle and Interfacial Technology Group, Ghent University, Coupure Links 653, B-9000, Ghent, Belgium
| | - Bas Hofs
- KWR Watercycle Research Institute, Groningenhaven 7, 3433 PE Nieuwegein, The Netherlands
| | - Willem-Jan Knibbe
- Oasen Drinking Water Company, Postbus 122, 2800 AC Gouda, The Netherlands
| | - Walter van der Meer
- Oasen Drinking Water Company, Postbus 122, 2800 AC Gouda, The Netherlands; Membrane Science and Technology Group, University of Twente, 7500 AE Enschede, The Netherlands
| | - Pim de Voogt
- Institute for Biodiversity and Ecosystem Dynamics, University of Amsterdam, Science Park 904, 1098 XH Amsterdam, The Netherlands; KWR Watercycle Research Institute, Groningenhaven 7, 3433 PE Nieuwegein, The Netherlands
| |
Collapse
|
14
|
Sousi M, Liu G, Salinas-Rodriguez SG, Knezev A, Blankert B, Schippers JC, van der Meer W, Kennedy MD. Further developing the bacterial growth potential method for ultra-pure drinking water produced by remineralization of reverse osmosis permeate. Water Res 2018; 145:687-696. [PMID: 30212807 DOI: 10.1016/j.watres.2018.09.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2018] [Revised: 08/15/2018] [Accepted: 09/02/2018] [Indexed: 06/08/2023]
Abstract
Ensuring the biological stability of drinking water is essential for modern drinking water supply. To understand and manage the biological stability, it is critical that the bacterial growth in drinking water can be measured. Nowadays, advance treatment technologies, such as reverse osmosis (RO), are increasingly applied in drinking water purification where the produced water is characterized by low levels of nutrients and cell counts. The challenge is, therefore, how to measure the low bacterial growth potential (BGP) of such ultra-pure water using the available methods which were originally developed for conventionally treated drinking water. In this study, we proposed a protocol to assess BGP of ultra-pure drinking water produced by RO and post-treatment (including remineralization). Natural bacterial consortium from conventional drinking water was added to all water samples during this study to ensure the presence of a wide range of bacterial strains. The method development included developing an ultra-pure blank with high reproducibility to lower the detection limit of the BGP method (50 ± 20 × 103 intact cells/mL) compared with conventional blanks such as bottled spring water, deep groundwater treated by aeration and slow sand filtrate of surface water supply. The ultra-low blank consists of RO permeate after adjusting its pH and essential mineral content under controlled laboratory conditions to ensure carbon limitation. Regarding the test protocol, inoculum concentrations of >10 × 103 intact cells/mL may have a significant contribution to the measured low levels of BGP. Pasteurization of water samples before measuring BGP is necessary to ensure reliable bacterial growth curves. The optimized method was used to assess BGP of ultra-pure drinking water produced by RO membranes and post-treatment (including remineralization), where the BGP has decreased more than 6-fold to a level of 90 ± 20 × 103 intact cells/mL compared with conventionally treated water (630 ± 70 × 103 intact cells/mL).
Collapse
Affiliation(s)
- Mohaned Sousi
- Department of Environmental Engineering and Water Technology, IHE Delft Institute for Water Education, Westvest 7, 2611 AX, Delft, the Netherlands; Faculty of Science and Technology, University of Twente, Drienerlolaan 5, 7522 NB, Enschede, the Netherlands
| | - Gang Liu
- Oasen Drinkwater, Nieuwe Gouwe O.Z. 3, 2801 SB, Gouda, the Netherlands; Department of Water Management, Faculty of Civil Engineering and Geoscience, Delft University of Technology, Stevinweg 1, 2628 CN, Delft, the Netherlands.
| | - Sergio G Salinas-Rodriguez
- Department of Environmental Engineering and Water Technology, IHE Delft Institute for Water Education, Westvest 7, 2611 AX, Delft, the Netherlands
| | - Aleksandra Knezev
- Het Waterlaboratorium, J.W. Lucasweg 2, 2031 BE, Haarlem, the Netherlands
| | - Bastiaan Blankert
- Oasen Drinkwater, Nieuwe Gouwe O.Z. 3, 2801 SB, Gouda, the Netherlands
| | - Jan C Schippers
- Department of Environmental Engineering and Water Technology, IHE Delft Institute for Water Education, Westvest 7, 2611 AX, Delft, the Netherlands
| | - Walter van der Meer
- Faculty of Science and Technology, University of Twente, Drienerlolaan 5, 7522 NB, Enschede, the Netherlands; Oasen Drinkwater, Nieuwe Gouwe O.Z. 3, 2801 SB, Gouda, the Netherlands
| | - Maria D Kennedy
- Department of Environmental Engineering and Water Technology, IHE Delft Institute for Water Education, Westvest 7, 2611 AX, Delft, the Netherlands; Department of Water Management, Faculty of Civil Engineering and Geoscience, Delft University of Technology, Stevinweg 1, 2628 CN, Delft, the Netherlands
| |
Collapse
|
15
|
Ma B, Li W, Liu R, Liu G, Sun J, Liu H, Qu J, van der Meer W. Multiple dynamic Al-based floc layers on ultrafiltration membrane surfaces for humic acid and reservoir water fouling reduction. Water Res 2018; 139:291-300. [PMID: 29656194 DOI: 10.1016/j.watres.2018.04.012] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2018] [Revised: 04/03/2018] [Accepted: 04/05/2018] [Indexed: 06/08/2023]
Abstract
The integration of adsorbents with ultrafiltration (UF) membranes is a promising method for alleviating membrane fouling and reducing land use. However, adsorbents typically are only injected into the membrane tank once, resulting in a single dynamic protection layer and low removal efficiency over long-term operation. In addition, the granular adsorbents used can cause membrane surface damage. To overcome these disadvantages, we injected inexpensive and loose aluminum (Al)-based flocs directly into a membrane tank with bottom aeration in the presence of humic acid (HA) or raw water taken from the Miyun Reservoir (Beijing, China). Results showed that the flocs were well suspended in the membrane tank, and multiple dynamic floc protection layers were formed (sandwich-like) on the membrane surface with multiple batch injections. Higher frequency floc injections resulted in better floc utilization efficiency and less severe membrane fouling. With continuous injection, acid solutions demonstrated better performance in removing HA molecules, especially those with small molecular weight, and in alleviating membrane fouling compared with the use of high aeration rate or polyacrylamide injection. This was attributed to the small particle size, large specific surface area, and high zeta potential of the flocs. Additionally, excellent UF membrane performance was exhibited by reservoir water with continuous injection and acid solution. Based on the outstanding UF membrane performance, this innovative integrated filtration with loose Al-based flocs has great application potential for water treatment.
Collapse
Affiliation(s)
- Baiwen Ma
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
| | - Wenjiang Li
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; Xi'an University of Architecture and Technology, Shaanxi 710055, China
| | - Ruiping Liu
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China.
| | - Gang Liu
- Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600GA Delft, The Netherlands
| | - Jingqiu Sun
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Huijuan Liu
- University of Chinese Academy of Sciences, Beijing 100049, China; State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
| | - Jiuhui Qu
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Walter van der Meer
- Science and Technology, University of Twente, P.O. Box 217, 7500AE Enschede, The Netherlands
| |
Collapse
|
16
|
Liu G, Zhang Y, van der Mark E, Magic-Knezev A, Pinto A, van den Bogert B, Liu W, van der Meer W, Medema G. Assessing the origin of bacteria in tap water and distribution system in an unchlorinated drinking water system by SourceTracker using microbial community fingerprints. Water Res 2018; 138:86-96. [PMID: 29573632 DOI: 10.1016/j.watres.2018.03.043] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2017] [Revised: 03/14/2018] [Accepted: 03/15/2018] [Indexed: 05/10/2023]
Abstract
The general consensus is that the abundance of tap water bacteria is greatly influenced by water purification and distribution. Those bacteria that are released from biofilm in the distribution system are especially considered as the major potential risk for drinking water bio-safety. For the first time, this full-scale study has captured and identified the proportional contribution of the source water, treated water, and distribution system in shaping the tap water bacterial community based on their microbial community fingerprints using the Bayesian "SourceTracker" method. The bacterial community profiles and diversity analyses illustrated that the water purification process shaped the community of planktonic and suspended particle-associated bacteria in treated water. The bacterial communities associated with suspended particles, loose deposits, and biofilm were similar to each other, while the community of tap water planktonic bacteria varied across different locations in distribution system. The microbial source tracking results showed that there was not a detectable contribution of source water to bacterial community in the tap water and distribution system. The planktonic bacteria in the treated water was the major contributor to planktonic bacteria in the tap water (17.7-54.1%). The particle-associated bacterial community in the treated water seeded the bacterial community associated with loose deposits (24.9-32.7%) and biofilm (37.8-43.8%) in the distribution system. In return, the loose deposits and biofilm showed a significant influence on tap water planktonic and particle-associated bacteria, which were location dependent and influenced by hydraulic changes. This was revealed by the increased contribution of loose deposits to tap water planktonic bacteria (from 2.5% to 38.0%) and an increased contribution of biofilm to tap water particle-associated bacteria (from 5.9% to 19.7%) caused by possible hydraulic disturbance from proximal to distal regions. Therefore, our findings indicate that the tap water bacteria could possibly be managed by selecting and operating the purification process properly and cleaning the distribution system effectively.
Collapse
Affiliation(s)
- Gang Liu
- Oasen Water Company, P.O. Box 122, 2800AC, Gouda, The Netherlands; Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600GA, Delft, The Netherlands.
| | - Ya Zhang
- Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign, 205 North Mathews Avenue, Urbana, IL, 61801, United States
| | - Ed van der Mark
- Dunea Water Company, P.O. Box 756, 2700 AT, Zoetermeer, The Netherlands
| | | | - Ameet Pinto
- Department of Civil and Environmental Engineering, Northeastern University, Boston, United States
| | | | - Wentso Liu
- Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign, 205 North Mathews Avenue, Urbana, IL, 61801, United States
| | - Walter van der Meer
- Oasen Water Company, P.O. Box 122, 2800AC, Gouda, The Netherlands; Science and Technology, University of Twente, P.O. Box 217, 7500AE, Enschede, The Netherlands
| | - Gertjan Medema
- Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600GA, Delft, The Netherlands; KWR Watercycle Research Institute, P.O. Box 1072, 3430 BB, Nieuwegein, The Netherlands
| |
Collapse
|
17
|
Liu G, Tao Y, Zhang Y, Lut M, Knibbe WJ, van der Wielen P, Liu W, Medema G, van der Meer W. Hotspots for selected metal elements and microbes accumulation and the corresponding water quality deterioration potential in an unchlorinated drinking water distribution system. Water Res 2017; 124:435-445. [PMID: 28787681 DOI: 10.1016/j.watres.2017.08.002] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2017] [Revised: 08/02/2017] [Accepted: 08/02/2017] [Indexed: 05/26/2023]
Abstract
Biofilm formation, loose deposit accumulation and water quality deterioration in drinking water distribution systems have been widely reported. However, the accumulation and distribution of harbored elements and microbes in the different niches (loose deposits, PVC-U biofilm, and HDPE biofilm) and their corresponding potential contribution to water quality deterioration remain unknown. This precludes an in-depth understanding of water quality deterioration and the development of proactive management strategies. The present study quantitatively evaluated the distribution of elements, ATP, Aeromonas spp., and bacterial communities in distribution pipes (PVC-U, D = 110 mm, loose deposit and biofilm niches) and household connection pipes (HDPE, D = 32 mm, HDPE biofilm niches) at ten locations in an unchlorinated distribution system. The results show that loose deposits in PVC-U pipes, acting as sinks, constitute a hotspot (highest total amount per meter pipe) for elements, ATP, and target bacteria groups (e.g., Aeromonas spp., Mycobacterium spp., and Legionella spp.). When drinking water distribution system niches with harbored elements and microbes become sources in the event of disturbances, the highest quality deterioration potential (QDP) is that of HDPE biofilm; this can be attributed to its high surface-to-volume ratio. 16s rRNA analysis demonstrates that, at the genus level, the bacterial communities in the water, loose deposits, PVC-U biofilm, and HDPE biofilm were dominated, respectively, by Polaromonas spp. (2-23%), Nitrosipra spp. (1-47%), Flavobacterium spp. (1-36%), and Flavobacterium spp. (5-67%). The combined results of elemental composition and bacterial community analyses indicate that different dominant bio-chemical processes might occur within the different niches-for example, iron-arsenic oxidizing in loose deposits, bio-calumniation in PVC-U biofilm, and methane oxidizing in HDPE biofilm. The release of 20% loose deposits, 20% PVC-U biofilm and 10% HDPE biofilm will cause significant changes of water bacterial community.
Collapse
Affiliation(s)
- Gang Liu
- Oasen Water Company, P.O. Box 122, 2800AC, Gouda, The Netherlands; Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600GA, Delft, The Netherlands.
| | - Yu Tao
- Department of Chemical Engineering, Imperial College London, South Kensington, London, SW7 2AZ, United Kingdom
| | - Ya Zhang
- Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign, 205 North Mathews Avenue, Urbana, IL, 61801, United States
| | - Maarten Lut
- Oasen Water Company, P.O. Box 122, 2800AC, Gouda, The Netherlands
| | | | - Paul van der Wielen
- KWR Watercycle Research Institute, P.O. Box 1072, 3430 BB, Nieuwegein, The Netherlands; Laboratory of Microbiology, Wageningen University, P.O. Box 8033, 6700 EH, Wageningen, The Netherlands
| | - Wentso Liu
- Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign, 205 North Mathews Avenue, Urbana, IL, 61801, United States
| | - Gertjan Medema
- Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600GA, Delft, The Netherlands; KWR Watercycle Research Institute, P.O. Box 1072, 3430 BB, Nieuwegein, The Netherlands
| | - Walter van der Meer
- Oasen Water Company, P.O. Box 122, 2800AC, Gouda, The Netherlands; Science and Technology, University of Twente, P.O. Box 217, 7500AE, Enschede, The Netherlands
| |
Collapse
|
18
|
Liu G, Zhang Y, Knibbe WJ, Feng C, Liu W, Medema G, van der Meer W. Potential impacts of changing supply-water quality on drinking water distribution: A review. Water Res 2017; 116:135-148. [PMID: 28329709 DOI: 10.1016/j.watres.2017.03.031] [Citation(s) in RCA: 104] [Impact Index Per Article: 14.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2016] [Revised: 02/17/2017] [Accepted: 03/15/2017] [Indexed: 05/12/2023]
Abstract
Driven by the development of water purification technologies and water quality regulations, the use of better source water and/or upgraded water treatment processes to improve drinking water quality have become common practices worldwide. However, even though these elements lead to improved water quality, the water quality may be impacted during its distribution through piped networks due to the processes such as pipe material release, biofilm formation and detachment, accumulation and resuspension of loose deposits. Irregular changes in supply-water quality may cause physiochemical and microbiological de-stabilization of pipe material, biofilms and loose deposits in the distribution system that have been established over decades and may harbor components that cause health or esthetical issues (brown water). Even though it is clearly relevant to customers' health (e.g., recent Flint water crisis), until now, switching of supply-water quality is done without any systematic evaluation. This article reviews the contaminants that develop in the water distribution system and their characteristics, as well as the possible transition effects during the switching of treated water quality by destabilization and the release of pipe material and contaminants into the water and the subsequent risks. At the end of this article, a framework is proposed for the evaluation of potential transition effects.
Collapse
Affiliation(s)
- Gang Liu
- Oasen Drinkwater, PO BOX 122, 2800 AC, Gouda, The Netherlands; Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600 GA, Delft, The Netherlands.
| | - Ya Zhang
- Department of Civil and Environmental Engineering, University of Illinois Urbana-Champaign, 205 N. Mathews Ave., Urbana, IL, 61801, USA
| | | | - Cuijie Feng
- Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600 GA, Delft, The Netherlands
| | - Wentso Liu
- Department of Civil and Environmental Engineering, University of Illinois Urbana-Champaign, 205 N. Mathews Ave., Urbana, IL, 61801, USA
| | - Gertjan Medema
- Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600 GA, Delft, The Netherlands; KWR Watercycle Research Institute, P.O. Box 1072, 3430 BB, Nieuwegein, The Netherlands
| | - Walter van der Meer
- Oasen Drinkwater, PO BOX 122, 2800 AC, Gouda, The Netherlands; Science and Technology, University of Twente, P.O. Box 217, 7500 AE, Enschede, The Netherlands
| |
Collapse
|
19
|
Yzerman E, den Boer JW, Caspers M, Almal A, Worzel B, van der Meer W, Montijn R, Schuren F. Comparative genome analysis of a large Dutch Legionella pneumophila strain collection identifies five markers highly correlated with clinical strains. BMC Genomics 2010; 11:433. [PMID: 20630115 PMCID: PMC3091632 DOI: 10.1186/1471-2164-11-433] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2010] [Accepted: 07/15/2010] [Indexed: 11/10/2022] Open
Abstract
Background Discrimination between clinical and environmental strains within many bacterial species is currently underexplored. Genomic analyses have clearly shown the enormous variability in genome composition between different strains of a bacterial species. In this study we have used Legionella pneumophila, the causative agent of Legionnaire's disease, to search for genomic markers related to pathogenicity. During a large surveillance study in The Netherlands well-characterized patient-derived strains and environmental strains were collected. We have used a mixed-genome microarray to perform comparative-genome analysis of 257 strains from this collection. Results Microarray analysis indicated that 480 DNA markers (out of in total 3360 markers) showed clear variation in presence between individual strains and these were therefore selected for further analysis. Unsupervised statistical analysis of these markers showed the enormous genomic variation within the species but did not show any correlation with a pathogenic phenotype. We therefore used supervised statistical analysis to identify discriminating markers. Genetic programming was used both to identify predictive markers and to define their interrelationships. A model consisting of five markers was developed that together correctly predicted 100% of the clinical strains and 69% of the environmental strains. Conclusions A novel approach for identifying predictive markers enabling discrimination between clinical and environmental isolates of L. pneumophila is presented. Out of over 3000 possible markers, five were selected that together enabled correct prediction of all the clinical strains included in this study. This novel approach for identifying predictive markers can be applied to all bacterial species, allowing for better discrimination between strains well equipped to cause human disease and relatively harmless strains.
Collapse
Affiliation(s)
- Ed Yzerman
- Regional Public Health Laboratory of Haarlem, Haarlem, the Netherlands
| | | | | | | | | | | | | | | |
Collapse
|
20
|
van der Marel P, Zwijnenburg A, Kemperman A, Wessling M, Temmink H, van der Meer W. Influence of membrane properties on fouling in submerged membrane bioreactors. J Memb Sci 2010. [DOI: 10.1016/j.memsci.2009.10.054] [Citation(s) in RCA: 118] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
21
|
|
22
|
Jiang T, Sin G, Spanjers H, Nopens I, Kennedy MD, van der Meer W, Futselaar H, Amy G, Vanrolleghem PA. Comparison of the modeling approach between membrane bioreactor and conventional activated sludge processes. Water Environ Res 2009; 81:432-440. [PMID: 19445333 DOI: 10.2175/106143008x370377] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Activated sludge models (ASM) have been developed and largely applied in conventional activated sludge (CAS) systems. The applicability of ASM to model membrane bioreactors (MBR) and the differences in modeling approaches have not been studied in detail. A laboratory-scale MBR was modeled using ASM2d. It was found that the ASM2d model structure can still be used for MBR modeling. There are significant differences related to ASM modeling. First, a lower maximum specific growth rate for MBR nitrifiers was estimated. Independent experiments demonstrated that this might be attributed to the inhibition effect of soluble microbial products (SMP) at elevated concentration. Second, a greater biomass affinity to oxygen and ammonium was found, which was probably related to smaller MBR sludge flocs. Finally, the membrane throughput during membrane backwashing/relaxation can be normalized and the membrane can be modeled as a continuous flow-through point separator. This simplicity has only a minor effect on ASM simulation results; however, it significantly improved simulation speed.
Collapse
Affiliation(s)
- Tao Jiang
- BIOMATH, Department of Applied Mathematics, Biometrics and Process Control, Ghent University, Gent, Flanders, Belgium.
| | | | | | | | | | | | | | | | | |
Collapse
|
23
|
van Voorthuizen E, Zwijnenburg A, van der Meer W, Temmink H. Biological black water treatment combined with membrane separation. Water Res 2008; 42:4334-4340. [PMID: 18774157 DOI: 10.1016/j.watres.2008.06.012] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/18/2008] [Revised: 06/05/2008] [Accepted: 06/06/2008] [Indexed: 05/26/2023]
Abstract
Separate treatment of black (toilet) water offers the possibility to recover energy and nutrients. In this study three combinations of biological treatment and membrane filtration were compared for their biological and membrane performance and nutrient conservation: a UASB followed by effluent membrane filtration, an anaerobic MBR and an aerobic MBR. Methane production in the anaerobic systems was lower than expected. Sludge production was highest in the aerobic MBR, followed by the anaerobic MBR and the UASB-membrane system. The level of nutrient conservation in the effluent was high in all three treatment systems, which is beneficial for their recovery from the effluent. Membrane treatment guaranteed an effluent which is free of suspended and colloidal matter. However, the concentration of soluble COD in the effluent still was relatively high and this may seriously hamper subsequent nutrient recovery by physical-chemical processes. The membrane filtration behaviour of the three systems was very different, and seemed to be dominated by the concentration of colloidals in the membrane feed. In general, membrane fouling was the lowest in the aerobic MBR, followed by the membranes used for UASB effluent filtration and the anaerobic MBR.
Collapse
|
24
|
Jiang T, Kennedy MD, Yoo C, Nopens I, van der Meer W, Futselaar H, Schippers JC, Vanrolleghem PA. Controlling submicron particle deposition in a side-stream membrane bioreactor: A theoretical hydrodynamic modelling approach incorporating energy consumption. J Memb Sci 2007. [DOI: 10.1016/j.memsci.2007.03.033] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
25
|
Castonguay MH, van der Schaaf S, Koester W, Krooneman J, van der Meer W, Harmsen H, Landini P. Biofilm formation by Escherichia coli is stimulated by synergistic interactions and co-adhesion mechanisms with adherence-proficient bacteria. Res Microbiol 2006; 157:471-8. [PMID: 16376056 DOI: 10.1016/j.resmic.2005.10.003] [Citation(s) in RCA: 99] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2005] [Revised: 09/30/2005] [Accepted: 10/18/2005] [Indexed: 11/17/2022]
Abstract
Laboratory strains of Escherichia coli do not show significant ability to attach to solid surfaces and to form biofilms. We compared the adhesion properties of the E. coli PHL565 laboratory strain to eight environmental E. coli isolates: only four isolates displayed adhesion properties to glass significantly higher than PHL565. The ability of the adhesion-proficient isolates to attach to glass tubes strongly correlated with their ability to express curli (thin aggregative fimbriae), thus suggesting that curli are a common adhesion determinant in environmental strains. Despite its inability to attach to solid surfaces, growth of E. coli PHL565 in mixed cultures with Pseudomonas putida MT2 resulted in co-adhesion and in formation of a mixed E. coli/P. putida biofilm, which was able to colonize glass surfaces with dramatic efficiency compared to P. putida alone. E. coli/P. putida interactions stimulate initial adhesion to glass, and the presence of both bacterial species in the mature biofilm was confirmed by quantitative PCR. In contrast, no synergistic biofilm formation was observed in mixed cultures of E. coli with the Gram-positive bacterium Staphylococcus epidermidis. Interestingly, E. coli PHL565 also stimulated biofilm formation by bacterial communities isolated from drinking water distribution systems. Our results strongly suggest that co-adhesion and synergistic interaction with biofilm-forming species might represent an important mechanism, and a possible alternative strategy to production of adhesion determinants, for persistence and propagation of E. coli in the environment.
Collapse
Affiliation(s)
- Marie-Hélène Castonguay
- Swiss Federal Institute of Environmental Technology (EAWAG), Ueberlandstrasse 133, 8600 Duebendorf, Switzerland
| | | | | | | | | | | | | |
Collapse
|