Marcelli S, Aso J. Preliminary outcomes and comparison of polytech POLYtxt
Ⓡ and MESMOsensitive
Ⓡ breast implants with focus on
late seroma: Single-surgeon, retrospective cohort study on 621 consecutive aesthetic breast surgery cases.
J Plast Reconstr Aesthet Surg 2021;
74:2217-2226. [PMID:
33582050 DOI:
10.1016/j.bjps.2020.12.092]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2020] [Revised: 11/29/2020] [Accepted: 12/22/2020] [Indexed: 10/22/2022]
Abstract
BACKGROUND
Recent history shows incomplete understanding of the long-term interaction between breast implants and biological tissues. Although complications of silicone-textured implants have been previously reported, conclusive data are still controversial due to the lack of reduced bias, long-term, comparative studies. We present our preliminary outcomes of 3 years aesthetic use of POLYTECH silicone POLYtxtⓇ and MESMO SensitiveⓇ implants.
METHODS
This article is a retrospective analysis of 621 patients who have undergone primary aesthetic breast surgery (breast augmentation (BA) or augmentation mastopexy). The surgeries were performed by a single surgeon using Polytech microtextured silicone implants (POLYtxt and MESMO). Complications, with main focus on late seroma, were assessed and compared based on texturization type.
RESULTS
From January 2015 to September 2018, 358 patients were treated with POLYtxt and 263 with MESMO-textured implants. Incidence of complications, such as hematoma, infection, early seroma, capsular contraction and malposition/rotation was comparable between the two groups. Incidence of late seroma was, respectively, 6.4% (POLYtxt) and 0% (MESMO) resulting in a statistically significant difference between the two groups. Overall complications and reinterventions were 12.5%-9.2% (POLYtxt) and 4.5%-3.8% (MESMO), respectively, showing a significantly lower occurrence in the MESMO group.
CONCLUSIONS
This reduced bias study shows an increased risk in overall complications and reoperations with POLYtxt surface implants compared with MESMO. Furthermore, we registered an exceptionally high rate of late seroma when the more "aggressive" POLYtxt texturization was used. Conversely, a significantly low incidence of adverse events was registered with the MESMO surface, which has turned this device in our first choice in daily practice.
Collapse