1
|
Yuan Q, Huang Y, Chi J, Wu W, Qi E. Gas-liquid contact evaporation of concentrate leachate from disk-tube reverse osmosis treatment in waste incineration plant. Environ Pollut 2024; 343:123271. [PMID: 38160769 DOI: 10.1016/j.envpol.2023.123271] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Revised: 12/20/2023] [Accepted: 12/28/2023] [Indexed: 01/03/2024]
Abstract
In order to utilize waste heat such as exhaust steam and hot air passing through air preheater in the waste incineration plant to heat air used for evaporating leachate concentrate (LC) by gas-liquid contact evaporation technology, hot air of 600 °C, 450 °C and 250 °C was used to evaporate LC in a laboratory-scale evaporator to obtain purified condensate used for supplying water for circulating cooling water system. The influence of pH, hot air temperature and evaporation rate on COD and NH3-N in condensate were investigated to identify the optimum operation of this technology. The results showed that COD concentration in condensate obviously decreased with increase in hot air temperature. Higher hot air temperature led to higher initial evaporation temperature, and evaporation rate of water was significantly greater than that of small molecular organic matter with lower boiling point than water with increasing hot air temperature. Reduction in contents of phenol, ketone and benzene was responsible for COD decreasing in condensate. COD in condensate decreased with increase in pH, as the amount of volatile organic matter such as fatty acids escaped from LC to condensate decreased. The pH had little influence on the DOM in condensate according to EEM spectra analysis. Evaporation rate had little influence on COD in the condensate water. NH3-N concentrations in condensate in all experimental groups were far away from the limit value (10 mg/L) in the water quality standard. Under the premise of meeting water quality standard, the lowest temperature (450 °C) of hot air was selected to save energy and use lower grade waste heat. Therefore, the optimum condition was 450 °C of hot air, pH = 7 of LC and CF = 10. At this condition, molecular weight of DOM in the condensate was smaller and humification degree and aromaticity of DOM were lower according to UV-visible absorption spectrum analysis.
Collapse
Affiliation(s)
- Qi Yuan
- Key Laboratory of Energy Thermal Conversion and Control of Ministry of Education, School of Energy and Environment, Southeast University, Nanjing, 210096, China; Jiangsu Environmental Engineering Technology Co., Ltd., Nanjing, 210019, China
| | - Yaji Huang
- Key Laboratory of Energy Thermal Conversion and Control of Ministry of Education, School of Energy and Environment, Southeast University, Nanjing, 210096, China.
| | - Jianzhou Chi
- Nanjing Linpu Thermal Energy Technology Co., LTD, Nanjing, 210019, China
| | - Wei Wu
- Nanjing Environment Group Co., LTD, Nanjing, 210026, China
| | - Erbing Qi
- Key Laboratory of Energy Thermal Conversion and Control of Ministry of Education, School of Energy and Environment, Southeast University, Nanjing, 210096, China
| |
Collapse
|
2
|
Yuan Q, Huang Y, Chi J, Wu W, Qi E. Effective treatment of leachate concentrate from waste incineration plant by combination of coagulation and direct contact evaporation. Chemosphere 2024; 349:140880. [PMID: 38061564 DOI: 10.1016/j.chemosphere.2023.140880] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/12/2023] [Revised: 11/22/2023] [Accepted: 12/01/2023] [Indexed: 01/10/2024]
Abstract
In order to verify that coagulation as pre-treatment can reduce the temperature of the hot air used for direct contact evaporating the leachate concentrate (LC) and low-grade waste heat such as exhaust steam in the waste incineration plant can be used to evaporate the LC. The supernatants after coagulation using polymerized ferrous sulfate (PFS), polymeric-aluminum (PAC), polymeric silicate aluminum ferric (PSAF) and poly-aluminum ferric chloride (PAFC) as coagulants were further treated in a lab-scale direct contact evaporation system. The results showed that the best performance with removal efficiencies of COD and NH3-N of 58.70% and 29.09% was achieved after coagulation when PAFC dosage = 15 g/L, PAM dosage = 30 mg/L and initial pH of supernatant = 6. After coagulation, a large amount of the fulvic-like acid and aromatic heterocyclic compounds were removed and the degree of complexity and aromaticity of organics decreased. After direct contact evaporation, using PAFC as coagulant still was the best selection due to its lowest concentrations of COD and NH3-N (22 mg/L and 1.02 mg/L) in the condensate produced by this two-stage treatment when initial pH of supernatant was 6 during evaporation and the condensate produced by this two-stage treatment met the water quality standard for using as supplying water for circulating cooling water system when temperature of hot air used for heating LC was at low temperature (250 °C). The fulvic-like acid and aromatic heterocyclic compounds in the condensate continuously reduced. Phenol, adamantane, 1-isocyanato, phthalic anhydrid, tri(2-chloroethyl) phosphat, Heptadecane, 2-methyl, ginsenol and Octadecane, 2-methyl- in the condensate obviously decreased. The effect of four coagulants as pretreatment on reducing the temperature of hot air used for evaporating LC was ranked as PAFC > PFS > PAC > PSAF. PSAF was not recommended due to the large amount of NH3-N produced when using PSAF to treat the LC.
Collapse
Affiliation(s)
- Qi Yuan
- Key Laboratory of Energy Thermal Conversion and Control of Ministry of Education, School of Energy and Environment, Southeast University, Nanjing, 210096, China; Jiangsu Environmental Engineering Technology Co., Ltd., Nanjing, 210019, China
| | - Yaji Huang
- Key Laboratory of Energy Thermal Conversion and Control of Ministry of Education, School of Energy and Environment, Southeast University, Nanjing, 210096, China.
| | - Jianzhou Chi
- Nanjing Linpu Thermal Energy Technology Co., Ltd, Nanjing, 210019, China
| | - Wei Wu
- Nanjing Environment Group Co., Ltd, Nanjing, 210026, China
| | - Erbing Qi
- Key Laboratory of Energy Thermal Conversion and Control of Ministry of Education, School of Energy and Environment, Southeast University, Nanjing, 210096, China
| |
Collapse
|
3
|
Hu P, Li H, Tan Y, Adeleye AS, Hao T. Enhanced electrochemical treatment of humic acids and metal ions in leachate concentrate: Experimental and molecular mechanism investigations. J Hazard Mater 2024; 462:132774. [PMID: 37839382 DOI: 10.1016/j.jhazmat.2023.132774] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Revised: 09/26/2023] [Accepted: 10/11/2023] [Indexed: 10/17/2023]
Abstract
Membrane technologies are effective for treating leachate, but they generate leachate concentrates (LCs), which contain elevated humic acids (HAs) and metals. LCs are very challenging and expensive to treat; but in-situ coagulation-electrochemical oxidation (CO-EO) treatment is promising. We previously hypothesized and proved that substituting the widely used graphite cathode with an Al cathode will generate Al(OH)3 floccules that would enhance HAs removal in CO-EO systems. However, the fundamental mechanisms are unclear. Here, we examined this hypothesis using laboratory experiments (using an Al cathode and a Ti/Ti4O7 anode CO-EO system) and performed molecular dynamics (MD) simulation to investigate the underlying mechanisms. Up to 84.2% HAs was removed by the Al-cathode system, which is ∼10% higher than a graphite cathode-based system. Based on MD simulation we found that enhanced HAs removal occurred via two steps: (1) degradation by oxidants produced at the anode, and (2) subsequent coagulation with the Al(OH)3 generated from the Al cathode. This finding challenges the current belief that whole HAs and Al(OH)3 directly flocculate. Meanwhile, metal removal efficiency by the graphite cathode system was only 0.8-13.9%, which increased up to 13-folds at most when in the Al cathode system. This work provides new molecular-level insights into an efficient electrochemical treatment of LC.
Collapse
Affiliation(s)
- Peng Hu
- Department of Civil and Environmental Engineering, Faculty of Science and Technology, University of Macau, Macau, China
| | - Huankai Li
- Department of Civil and Environmental Engineering, Faculty of Science and Technology, University of Macau, Macau, China
| | - Yunkai Tan
- Department of Civil and Environmental Engineering, Faculty of Science and Technology, University of Macau, Macau, China
| | - Adeyemi S Adeleye
- Department of Civil and Environmental Engineering, University of California, Irvine, Irvine, CA 92697-2175, USA
| | - Tianwei Hao
- Department of Civil and Environmental Engineering, Faculty of Science and Technology, University of Macau, Macau, China.
| |
Collapse
|
4
|
Li H, Zeng Q, Zan F, Lin S, Hao T. In situ coagulation-electrochemical oxidation of leachate concentrate: A key role of cathodes. Environ Sci Ecotechnol 2023; 16:100267. [PMID: 37065009 PMCID: PMC10091031 DOI: 10.1016/j.ese.2023.100267] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2022] [Revised: 02/25/2023] [Accepted: 03/13/2023] [Indexed: 06/19/2023]
Abstract
To efficiently remove organic and inorganic pollutants from leachate concentrate, an in situ coagulation-electrochemical oxidation (CO-EO) system was proposed using Ti/Ti4O7 anode and Al cathode, coupling the "super-Faradaic" dissolution of Al. The system was evaluated in terms of the removal efficiencies of organics, nutrients, and metals, and the underlying cathodic mechanisms were investigated compared with the Ti/RuO2-IrO2 and graphite cathode systems. After a 3-h treatment, the Al-cathode system removed 89.0% of COD and 36.3% of total nitrogen (TN). The TN removal was primarily ascribed to the oxidation of both ammonia and organic-N to N2. In comparison, the Al-cathode system achieved 3-10-fold total phosphorus (TP) (62.6%) and metal removals (>80%) than Ti/RuO2-IrO2 and graphite systems. The increased removals of TP and metals were ascribed to the in situ coagulation of Al(OH)3, hydroxide precipitation, and electrodeposition. With the reduced scaling on the Al cathode surface, the formation of Al3+ and electrified Al(OH)3 lessened the requirement for cathode cleaning and increased the bulk conductivity, resulting in increased instantaneous current production (38.9%) and operating cost efficiencies (48.3 kWh kgCOD -1). The present study indicated that the in situ CO-EO process could be potentially used for treating persistent wastewater containing high levels of organic and inorganic ions.
Collapse
Affiliation(s)
- Huankai Li
- Department of Civil and Environmental Engineering, Faculty of Science and Technology, University of Macau, Macau, China
| | - Qian Zeng
- Department of Civil and Environmental Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Hong Kong, China
| | - Feixiang Zan
- School of Environmental Science and Engineering, Low-Carbon Water Environment Technology Center (HUST-SUKE), Huazhong University of Science and Technology, Wuhan, China
| | - Sen Lin
- Department of Civil and Environmental Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Hong Kong, China
| | - Tianwei Hao
- Department of Civil and Environmental Engineering, Faculty of Science and Technology, University of Macau, Macau, China
| |
Collapse
|
5
|
Li T, Lü F, Qiu J, Zhang H, He P. Substance flow analysis on the leachate DOM molecules along five typical membrane advanced treatment processes. Water Res 2023; 228:119348. [PMID: 36403296 DOI: 10.1016/j.watres.2022.119348] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/05/2022] [Revised: 11/04/2022] [Accepted: 11/08/2022] [Indexed: 06/16/2023]
Abstract
The processes combining biological treatment with membrane separation technologies have been widely adopted for leachate treatment. However, dissolved organic matter (DOM) of leachate membrane concentrates generated from various membrane separation technologies has not been systematically investigated in field scale. Therefore, substance flow analysis based on DOM molecular information of leachate membrane concentrates from primary membrane systems (i.e. nanofiltration (NF) and reverse osmosis (RO)) and secondary membrane systems (i.e. disk-tube reverse osmosis (DTRO) and humic substance filtration system (HSF)) in five engineering-scale leachate treatment facilities, obtained via ultra-performance liquid chromatography coupled with hybrid quadrupole Orbitrap mass spectrometry, was given and simultaneously compared. In NF concentrates (NFC), 45.1-98.5% of DOM originated from raw leachate (L-DOM) was concentrated, showing poor biodegradability. The L-DOM interception characteristics of NFC-fed HSF were mainly based on volume reduction but concentration effect. L-DOM in RO concentrates (ROC) showed a higher proportion of peak intensity reduced components, accounting for 50.3-96.8%, and organic composition changes were more dependent on water quality characteristics than membrane types. ROC-fed DTRO intercepted 49.3-72.6% of L-DOM, but DTRO may be less effective at intercepting DOM molecules in landfill leachate with higher oxidation levels. Considering risks from feasible treatment technologies, the difficulty for the treatment of leachate membrane concentrates followed the order of DTRO concentrates > ROC > NFC. This study suggests that ROC-fed DTRO need to be controlled to avoid amplifying the treatment difficulty. Besides, treatment technologies for RO and DTRO concentrates with low-concentrated but refractory DOM and high salts should be explored.
Collapse
Affiliation(s)
- Tianqi Li
- Institute of Waste Treatment and Reclamation, Tongji University, Shanghai, 200092, PR China
| | - Fan Lü
- Institute of Waste Treatment and Reclamation, Tongji University, Shanghai, 200092, PR China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai, 200092, PR China; Shanghai Engineering Research Center of Multi-source Solid Wastes Co-processing and Energy Utilization, Shanghai, 200092, PR China
| | - Junjie Qiu
- Institute of Waste Treatment and Reclamation, Tongji University, Shanghai, 200092, PR China
| | - Hua Zhang
- Institute of Waste Treatment and Reclamation, Tongji University, Shanghai, 200092, PR China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai, 200092, PR China; Shanghai Engineering Research Center of Multi-source Solid Wastes Co-processing and Energy Utilization, Shanghai, 200092, PR China
| | - Pinjing He
- Institute of Waste Treatment and Reclamation, Tongji University, Shanghai, 200092, PR China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai, 200092, PR China; Shanghai Engineering Research Center of Multi-source Solid Wastes Co-processing and Energy Utilization, Shanghai, 200092, PR China.
| |
Collapse
|