Kamisaki F, Inoue T, Tomiyoshi K, Matsuki M, Aoki K, Kusaka S, Tamaki S, Sato F, Murata I. Accurate gamma-ray dose measurement up to 10 MeV by glass dosimeter with a sensitivity control filter for BNCT. Appl Radiat Isot 2024; 209:111299. [PMID: 38613949 DOI: 10.1016/j.apradiso.2024.111299] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2022] [Revised: 01/28/2024] [Accepted: 03/18/2024] [Indexed: 04/15/2024]
Abstract
Glass dosimeters are very useful and convenient detection elements in radiation dosimetry. In this study, this glass dosimeter was applied to a BNCT treatment field. Boron Neutron Capture Therapy (BNCT) is a next-generation radiation therapy that can selectively kill only cancer cells. In the BNCT treatment field, both neutrons and secondary gamma-rays are generated. In other words, it is a mixed radiation field of neutrons and gamma-rays. We thus proposed a novel method to measure only gamma-ray dose in the mixed field using two RPLGD (Radiophoto-luminescence Glass Dosimeter) and two sensitivity control filters in order to control the dose response of the filtered RPLGD to be proportional to the air kerma coefficients, even if the gamma-ray energy spectrum is unknown. As the filter material iron was selected, and it was finally confirmed that reproduction of the air kerma coefficients was excellent within an error of 5.3% in the entire energy range up to 10 MeV. In order to validate this method, irradiation experiments were carried out using standard gamma-ray sources. As the result, the measured doses were in acceptably good agreement with the theoretical calculation results by PHITS. In the irradiation experiment with a volume source in a nuclear fuel storage room, the measured dose rates showed larger compared with survey meter values. In conclusion, the results of the standard sources showed the feasibility of this method, however for the volume source the dependence of the gamma-ray incident angle on the dosimeter was found to be not neglected. In the next step, it will be necessary to design a thinner filter in order to suppress the effect of the incident angle.
Collapse
Affiliation(s)
- F Kamisaki
- Graduate School of Engineering, Osaka University, Yamada-oka 2-1, Suita, Osaka, 565-0871, Japan
| | - T Inoue
- Graduate School of Engineering, Osaka University, Yamada-oka 2-1, Suita, Osaka, 565-0871, Japan
| | - K Tomiyoshi
- Graduate School of Engineering, Osaka University, Yamada-oka 2-1, Suita, Osaka, 565-0871, Japan
| | - M Matsuki
- Graduate School of Engineering, Osaka University, Yamada-oka 2-1, Suita, Osaka, 565-0871, Japan
| | - K Aoki
- Graduate School of Engineering, Osaka University, Yamada-oka 2-1, Suita, Osaka, 565-0871, Japan
| | - S Kusaka
- Graduate School of Engineering, Osaka University, Yamada-oka 2-1, Suita, Osaka, 565-0871, Japan
| | - S Tamaki
- Graduate School of Engineering, Osaka University, Yamada-oka 2-1, Suita, Osaka, 565-0871, Japan
| | - F Sato
- Graduate School of Engineering, Osaka University, Yamada-oka 2-1, Suita, Osaka, 565-0871, Japan
| | - I Murata
- Graduate School of Engineering, Osaka University, Yamada-oka 2-1, Suita, Osaka, 565-0871, Japan.
| |
Collapse
|
2
|
Kweon DC. Radiation exposure in cone beam CT measured using a MOSFET and RPLGD dosimeter and Monte Carlo simulation in phantom. J Xray Sci Technol 2023:XST230026. [PMID: 37248944 DOI: 10.3233/xst-230026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
BACKGROUND Due to the wide application of the cone beam computed tomography (CBCT) in clinical practice, it is important to assess radiation dose of CBCT more accurately and efficiently in different clinical applications. OBJECTIVE This study aims to calculate effective and absorbed doses in CBCT measured in an anthropomorphic phantom using computer-based Monte Carlo (PCXMC) software, and to conduct comparative evaluations of MOSFET (metal- oxide- semiconductor field-effect transistor) and radiophotoluminescence glass dosimeters (RPLGD). METHODS Effective and absorbed organ doses are compared with those obtained using MOSFET and RPLGD dosimetry in an anthropomorphic phantom given the same exposure settings. Effective and absorbed organ doses from CBCT during scout and main projections are calculated using PCXMC and PCXMCRotation software, respectively. RESULTS The mean effective dose from CBCT calculated using PCXMC software is 233.8μSv, while the doses calculated using dosimetry (MOSFET and RPLGD) are 266.67μSv and 268.78μSv, respectively. The X-ray source variation is 0.79%. The prescription limits based on the Friedman test for MOSFET and RPLGD pre-points (i.e., in an analytical analysis of diagnostic names in CBCT) are not statistically significant. The calculated correlation coefficient between MOSFET- and RPLGD-derived absorbed dose values with respect to a field of view CBCT parameter of 17×13.5 mm is r = 0.8623. CONCLUSIONS The study demonstrates that the PCXMC software may be used as an alternative to MOSFET and RPLGD dosimetry for effective and absorbed organ dose estimation in CBCT conducted with a large FOV in an anthropomorphic phantom.
Collapse
Affiliation(s)
- Dae Cheol Kweon
- Department of Radiological Science, Shinhan University, Uijeongbu, Republic of Korea
| |
Collapse
|