1
|
Maldonado-Barrueco A, Sanz-González C, Falces-Romero I, García-Clemente P, Cacho-Calvo J, Quiles-Melero I. Comparison of gradient diffusion and molecular methods using Allplex™ NG&DR assay ( Seegene®) for macrolide and fluoroquinolone screening resistance in Neisseria gonorrhoeae. Eur J Clin Microbiol Infect Dis 2024:10.1007/s10096-024-04786-y. [PMID: 38407691 DOI: 10.1007/s10096-024-04786-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Accepted: 02/12/2024] [Indexed: 02/27/2024]
Abstract
Antimicrobial resistance in Neisseria gonorrhoeae (NG) is increasing worldwide. Second-line treatments with macrolides or fluoroquinolones are an option for NG infections in some cases following the STI guideline recommendations. In our study, we compared the gradient diffusion test using EUCAST 2024 breakpoints with a new molecular method using the Allplex™ NG&DR assay (Seegene®) including A2059G/C2611 mutations (23S rRNA) associated with high/moderate-level macrolide resistance and S91F mutation (gyrA) relationship with fluoroquinolone resistance in NG isolates (n = 100). We calculated the sensitivity, specificity, and correlation of the molecular test for fluoroquinolone using the gradient diffusion as the reference method. In twenty-three strains was not detected any mutation associated with macrolides or fluoroquinolone resistance. No A2059G/C2611T mutations were detected, and the S91F mutations were detected in 77 out of the 100 isolates screened. Twenty-three NG isolates were reported to be resistant to azithromycin (ECOFF: >1 mg/L), and 78 NG isolates were resistant to ciprofloxacin (MIC: >0.06 mg/L). The molecular method showed a sensitivity of 96.1% and, a specificity of 90.9% for fluoroquinolone susceptibility, but the statistical analysis between the molecular test and gradient diffusion test was not statistically significant for fluoroquinolone resistance (p = 1). Statistical analysis was not performed for macrolides because of the absence of positive RT-PCR results. According to our data, Allplex™ assay cannot replace the gradient diffusion test for macrolide resistance. However, the assay could be used to test fluoroquinolone resistance in NG isolates as a replacement for phenotypic methods.
Collapse
Affiliation(s)
| | - Claudia Sanz-González
- Clinical Microbiology Department, Hospital Universitario La Paz, 261, Madrid, 28046, Spain
| | - Iker Falces-Romero
- Clinical Microbiology Department, Hospital Universitario La Paz, 261, Madrid, 28046, Spain
- CIBERINFEC, Instituto de Salud Carlos III, Madrid, Spain
| | - Paloma García-Clemente
- Clinical Microbiology Department, Hospital Universitario La Paz, 261, Madrid, 28046, Spain
| | - Juana Cacho-Calvo
- Clinical Microbiology Department, Hospital Universitario La Paz, 261, Madrid, 28046, Spain
| | | |
Collapse
|
2
|
Chung PYJ, Dhillon SK, Simoens C, Cuypers L, Laenen L, Bonde J, Corbisier P, Buttinger G, Cocuzza CE, Van Gucht S, Van Ranst M, Arbyn M. Assessment of the clinical and analytical performance of three Seegene Allplex SARS-CoV-2 assays within the VALCOR framework. Microbiol Spectr 2024; 12:e0239723. [PMID: 38189291 PMCID: PMC10846132 DOI: 10.1128/spectrum.02397-23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2023] [Accepted: 12/05/2023] [Indexed: 01/09/2024] Open
Abstract
The coronavirus disease 2019 (COVID-19) pandemic demonstrated the need for accurate diagnostic testing for the early detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Although the pandemic has ended, accurate assays are still needed to monitor viral spread at national levels and beyond through population and wastewater surveillance. To enhance early detection, SARS-CoV-2 assays should have high diagnostic accuracy and should be validated to assure accurate results. Three distinct SARS-CoV-2 assays were evaluated with clinical samples using the VALCOR (VALidation of SARS-CORona Virus-2 assays) framework, with the TaqPath COVID-19 assay (ThermoFisher Scientific, USA) as a comparator. We evaluated clinical sensitivity, specificity, limit of detection (LOD), and overall concordance between comparator and three index Allplex SARS-CoV-2 assays (Seegene, South Korea): Allplex-SC2, Allplex-SC2Fast (Fast PCR), and Allplex-SC2FabR (SARS-CoV-2/FluA/FluB/respiratory syncytial virus). Analytical performance and LOD of index assays were assessed using a dilution series of three synthetic SARS-CoV-2 sequence reference materials (RMs). Ninety SARS-CoV-2 positives and 90 SARS-CoV-2 negatives were tested. All Allplex assays had 100.0% sensitivity (95%CI = 95.9%-100.0%). Allplex-SC2 and Allplex-SC2Fast assays had 97.8% specificity (95%CI = 92.3%-99.7%) and 98.9% overall concordance [κ = 0.978 (95%CI = 0.947-1.000)]. Allplex-SC2FabR assay showed 100.0% specificity (95%CI = 95.9%-100.0%) and 100.0% overall concordance [κ = 1.000 (95%CI = 1.000-1.000)]. LOD assessment of index assays revealed detection down to 2.61 × 102 copies/mL in clinical samples, while the analytical LOD was 9.00 × 102 copies/mL. In conclusion, the evaluation of the three Seegene Allplex SARS-CoV-2 assays showed high sensitivity and specificity and an overall good assay concordance with the comparator. The assays showed low analytical LOD using RM and even a slightly lower LOD in clinical samples. Non-overlapping target gene sequences between SARS-CoV-2 assays and RMs emphasize the need for aligning targeted sequences of diagnostic assays and RMs.IMPORTANCEThe coronavirus disease 2019 pandemic has a significant impact on global public health, economies, and societies. As shown through the first phases of the pandemic, accurate and timely diagnosis is crucial for disease control, prevention, and monitoring. Though the pandemic phase of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has concluded, diagnostic assays remain in demand to monitor SARS-CoV-2 at the individual patient level, regionally, and nationally, as well as to remain an infectious disease preparedness instrument to monitor any new SARS-CoV-2 dissemination across borders using population and wastewater surveillance. The anticipation by WHO and central health care policy entities such as the Center for Disease Control, EMA, and multiple national health authorities is that SARS-CoV-2 will reside as an endemic respiratory disease for years to come. The key strategic consideration is hence shifting from combating a pandemic situation with a high number of patients to instead allowing precise diagnostics of suspected patients with the intention of correct management in a low-prevalence setting.
Collapse
Affiliation(s)
- Pui Yan Jenny Chung
- Unit of Cancer Epidemiology, Belgian Cancer Centre, Sciensano, Brussels, Belgium
| | - Sharonjit K. Dhillon
- Unit of Cancer Epidemiology, Belgian Cancer Centre, Sciensano, Brussels, Belgium
| | - Cindy Simoens
- Unit of Cancer Epidemiology, Belgian Cancer Centre, Sciensano, Brussels, Belgium
| | - Lize Cuypers
- Department of Laboratory Medicine, National Reference Centre for Respiratory Pathogens, University Hospitals Leuven, Leuven, Belgium
- Laboratory of Clinical Microbiology, Department of Microbiology, Immunology and Transplantation, KU Leuven, Leuven, Belgium
| | - Lies Laenen
- Department of Laboratory Medicine, National Reference Centre for Respiratory Pathogens, University Hospitals Leuven, Leuven, Belgium
- Laboratory of Clinical Microbiology, Department of Microbiology, Immunology and Transplantation, KU Leuven, Leuven, Belgium
| | - Jesper Bonde
- Molecular Pathology Laboratory, Department of Pathology, AHH-Hvidovre Hospital, Copenhagen University Hospital, Copenhagen, Denmark
| | | | | | - Clementina E. Cocuzza
- Laboratory of Clinical Microbiology and Virology, Department of Medicine and Surgery, University of Milano-Bicocca, Monza, Italy
| | | | - Marc Van Ranst
- Laboratory of Clinical and Epidemiological Virology, Department of Microbiology, Immunology and Transplantation, Rega Institute for Medical Research, KU Leuven, Leuven, Belgium
| | - Marc Arbyn
- Unit of Cancer Epidemiology, Belgian Cancer Centre, Sciensano, Brussels, Belgium
- Department of Human Structure and Repair, Faculty of Medicine and Health Sciences, University of Ghent, Ghent, Belgium
| |
Collapse
|
3
|
Freire-Paspuel B, Garcia-Bereguiain MA. Analytical and Clinical Evaluation of "AccuPower SARS-CoV-2 Multiplex RT-PCR kit (Bioneer, South Korea)" and "Allplex 2019-nCoV Assay ( Seegene, South Korea)" for SARS-CoV-2 RT-PCR Diagnosis: Korean CDC EUA as a Quality Control Proxy for Developing Countries. Front Cell Infect Microbiol 2021; 11:630552. [PMID: 34178716 PMCID: PMC8223252 DOI: 10.3389/fcimb.2021.630552] [Citation(s) in RCA: 35] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2020] [Accepted: 02/10/2021] [Indexed: 12/11/2022] Open
Abstract
Background Multiple RT-qPCR kits are available in the market for SARS-CoV-2 diagnosis, some of them with Emergency Use Authorization (EUA) by FDA or their country of origin agency, but many of them lack of proper clinical evaluation. Objective We evaluated the clinical performance of two Korean SARS-CoV-2 RT-PCR kits available in South America, AccuPower SARS-CoV-2 Multiplex RT-PCR kit (Bioneer, South Korea) and Allplex 2019-nCoV Assay (Seegene, South Korea), for RT-qPCR SARS-CoV-2 diagnosis using the CDC protocol as a gold standard. Results We found strong differences among both kits clinical performance and analytical sensitivity; while the Allplex 2019-nCoV Assay has sensitivity of 96.5% and an estimated limit of detection of 4,000 copies/ml, the AccuPower SARS-CoV-2 Multiplex RT-PCR kit has a sensitivity of 75.5% and limit of detection estimated to be bigger than 20,000 copies/ml. Conclusions AccuPower SARS-CoV-2 Multiplex RT-PCR kit and Allplex 2019-nCoV Assay are both made in South Korea but EUA by Korean CDC was only granted to the later. Our results support that Korean CDC EUA should be considered as a quality control proxy for Korean SARS-CoV-2 RT-PCR kits prior to importation by developing countries to guarantee high sensitivity diagnosis.
Collapse
|