1
|
van der Zander QEW, Schreuder RM, Thijssen A, Kusters CHJ, Dehghani N, Scheeve T, Winkens B, van der Ende - van Loon MCM, de With PHN, van der Sommen F, Masclee AAM, Schoon EJ. Artificial intelligence for characterization of diminutive colorectal polyps: A feasibility study comparing two computer-aided diagnosis systems. Artif Intell Gastrointest Endosc 2024; 5:90574. [DOI: 10.37126/aige.v5.i1.90574] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/07/2023] [Revised: 01/11/2024] [Accepted: 02/02/2024] [Indexed: 02/20/2024] Open
Abstract
BACKGROUND Artificial intelligence (AI) has potential in the optical diagnosis of colorectal polyps.
AIM To evaluate the feasibility of the real-time use of the computer-aided diagnosis system (CADx) AI for ColoRectal Polyps (AI4CRP) for the optical diagnosis of diminutive colorectal polyps and to compare the performance with CAD EYETM (Fujifilm, Tokyo, Japan). CADx influence on the optical diagnosis of an expert endoscopist was also investigated.
METHODS AI4CRP was developed in-house and CAD EYE was proprietary software provided by Fujifilm. Both CADx-systems exploit convolutional neural networks. Colorectal polyps were characterized as benign or premalignant and histopathology was used as gold standard. AI4CRP provided an objective assessment of its characterization by presenting a calibrated confidence characterization value (range 0.0-1.0). A predefined cut-off value of 0.6 was set with values < 0.6 indicating benign and values ≥ 0.6 indicating premalignant colorectal polyps. Low confidence characterizations were defined as values 40% around the cut-off value of 0.6 (< 0.36 and > 0.76). Self-critical AI4CRP’s diagnostic performances excluded low confidence characterizations.
RESULTS AI4CRP use was feasible and performed on 30 patients with 51 colorectal polyps. Self-critical AI4CRP, excluding 14 low confidence characterizations [27.5% (14/51)], had a diagnostic accuracy of 89.2%, sensitivity of 89.7%, and specificity of 87.5%, which was higher compared to AI4CRP. CAD EYE had a 83.7% diagnostic accuracy, 74.2% sensitivity, and 100.0% specificity. Diagnostic performances of the endoscopist alone (before AI) increased non-significantly after reviewing the CADx characterizations of both AI4CRP and CAD EYE (AI-assisted endoscopist). Diagnostic performances of the AI-assisted endoscopist were higher compared to both CADx-systems, except for specificity for which CAD EYE performed best.
CONCLUSION Real-time use of AI4CRP was feasible. Objective confidence values provided by a CADx is novel and self-critical AI4CRP showed higher diagnostic performances compared to AI4CRP.
Collapse
Affiliation(s)
- Quirine Eunice Wennie van der Zander
- Department of Gastroenterology and Hepatology, Maastricht University Medical Center, Maastricht 6202 AZ, Netherlands
- GROW, School for Oncology and Reproduction, Maastricht University, Maastricht 6200 MD, Netherlands
| | - Ramon M Schreuder
- Division of Gastroenterology and Hepatology, Catharina Hospital Eindhoven, Eindhoven 5602 ZA, Netherlands
| | - Ayla Thijssen
- Department of Gastroenterology and Hepatology, Maastricht University Medical Center, Maastricht 6202 AZ, Netherlands
- GROW, School for Oncology and Reproduction, Maastricht University, Maastricht 6200 MD, Netherlands
| | - Carolus H J Kusters
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven 5600 MB, Netherlands
| | - Nikoo Dehghani
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven 5600 MB, Netherlands
| | - Thom Scheeve
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven 5600 MB, Netherlands
| | - Bjorn Winkens
- Department of Methodology and Statistics, Maastricht University, Postbus 616, 6200 MD Maastricht, Netherlands
- School for Public Health and Primary Care, Maastricht University, Maastricht 6200 MD, Netherlands
| | | | - Peter H N de With
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven 5600 MB, Netherlands
| | - Fons van der Sommen
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven 5600 MB, Netherlands
| | - Ad A M Masclee
- Department of Gastroenterology and Hepatology, Maastricht University Medical Center, Maastricht 6202 AZ, Netherlands
| | - Erik J Schoon
- GROW, School for Oncology and Reproduction, Maastricht University, Maastricht 6200 MD, Netherlands
- Division of Gastroenterology and Hepatology, Catharina Hospital Eindhoven, Eindhoven 5602 ZA, Netherlands
| |
Collapse
|