1
|
Turrina C, Klassen A, Milani D, Rojas-González DM, Ledinski G, Auer D, Sartori B, Cvirn G, Mela P, Berensmeier S, Schwaminger SP. Superparamagnetic iron oxide nanoparticles for their application in the human body: Influence of the surface. Heliyon 2023; 9:e16487. [PMID: 37274707 PMCID: PMC10238907 DOI: 10.1016/j.heliyon.2023.e16487] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 05/16/2023] [Accepted: 05/18/2023] [Indexed: 06/06/2023] Open
Abstract
Iron oxide nanoparticles (IONs) are of great interest in nanomedicine for imaging, drug delivery, or for hyperthermia treatment. Although many research groups have focused on the synthesis and application of IONs in nanomedicine, little is known about the influence of the surface properties on the particles' behavior in the human body. This study analyzes the impact of surface coatings (dextran, polyvinyl alcohol, polylactide-co-glycolide) on the nanoparticles' cytocompatibility, agglomeration, degradation, and the resulting oxidative stress induced by the particle degradation. All particles, including bare IONs (BIONs), are highly cytocompatible (>70%) and show no significant toxicity towards smooth muscle cells. Small-angle X-ray scattering profiles visualize the aggregation behavior of nanoparticles and yield primary particle sizes of around 20 nm for the investigated nanoparticles. A combined experimental setup of dynamic light scattering and phenanthroline assay was used to analyze the long-term agglomeration and degradation profile of IONs in simulated body fluids, allowing fast screening of multiple candidates. All particles degraded in simulated endosomal and lysosomal fluid, confirming the pH-dependent dissolution. The degradation rate decreased with the shrinking size of particles leading to a plateau. The fastest Fe2+ release could be measured for the polyvinyl-coated IONs. The analytical setup is ideal for a quick preclinical study of IONs, giving often neglected yet crucial information about the behavior and toxicity of nanoparticles in the human body. Moreover, this study allows for the development and evaluation of novel ferroptosis-inducing agents.
Collapse
Affiliation(s)
- Chiara Turrina
- Chair of Bioseparation Engineering, TUM School of Engineering and Design, Technical University of Munich, Germany
| | - Anna Klassen
- Chair of Bioseparation Engineering, TUM School of Engineering and Design, Technical University of Munich, Germany
| | - Davide Milani
- Chair of Bioseparation Engineering, TUM School of Engineering and Design, Technical University of Munich, Germany
| | - Diana M. Rojas-González
- Chair of Medical Materials and Implants, TUM School of Engineering and Design, Munich Institute of Biomedical Engineering, Technical University of Munich, Germany
| | - Gerhard Ledinski
- Division of Medicinal Chemistry, Otto Loewi Research Center, Medical University of Graz, Austria
| | - Doris Auer
- Division of Medical Physics and Biophysics, Gottfried Schatz Research Center, Medical University of Graz, Austria
| | - Barbara Sartori
- Institute of Inorganic Chemistry, Graz University of Technology, Stremayrgasse 9/IV, Graz, 8010, Austria
| | - Gerhard Cvirn
- Division of Medicinal Chemistry, Otto Loewi Research Center, Medical University of Graz, Austria
| | - Petra Mela
- Chair of Medical Materials and Implants, TUM School of Engineering and Design, Munich Institute of Biomedical Engineering, Technical University of Munich, Germany
| | - Sonja Berensmeier
- Chair of Bioseparation Engineering, TUM School of Engineering and Design, Technical University of Munich, Germany
| | - Sebastian P. Schwaminger
- Chair of Bioseparation Engineering, TUM School of Engineering and Design, Technical University of Munich, Germany
- Division of Medicinal Chemistry, Otto Loewi Research Center, Medical University of Graz, Austria
- BioTechMed-Graz, Austria
| |
Collapse
|
2
|
Lai Y, Dong L, Sheng X, Chao J, Yu S, Liu J. Monitoring the Cd 2+ release from Cd-containing quantum dots in simulated body fluids by size exclusion chromatography coupled with ICP-MS. Anal Bioanal Chem 2022; 414:5529-5536. [PMID: 35212781 DOI: 10.1007/s00216-022-03976-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Revised: 02/09/2022] [Accepted: 02/11/2022] [Indexed: 11/29/2022]
Abstract
Quantification of Cd2+ release from Cd-containing quantum dots (QDs) is of fundamental importance to elucidate its toxicity to organisms, but remains a great challenge due to the lack of appropriate analytical method. Herein, a facile method based on size exclusion chromatography (SEC) combined with inductively coupled plasma mass spectrometry (ICP-MS) was developed for separating and quantifying the QDs and counterpart ions. By using the mixture of sodium dodecyl sulfate (SDS) and ethylenediaminetetraacetic acid tetrasodium salt (EDTA) as the mobile phase, the defect of QD and ion adsorption onto the SEC column was overcome, thus realizing the accurate quantification of ionic species. Besides, the concentration of QDs was achieved through subtracting the ion concentration from the total concentration. Selecting CdSe@ZnS as the typical QDs, the Cd2+ release process in four typical simulated body fluids, namely, simulated gastric fluid, simulated sweat, Gamble's solution, and artificial lysosomal fluid, was monitored using the developed SEC-ICP-MS method. The media pH is identified as the decisive factor which controls the dissolution of ZnS shells and also the Cd2+ release kinetics and final concentration. Our results suggest that the oral pathway for QD uptake poses the biggest risk to human health.
Collapse
Affiliation(s)
- Yujian Lai
- School of Environment, Hangzhou Institute for Advanced Study, UCAS, Hangzhou, 310024, China.,State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P. O. Box 2871, Beijing, 100085, China
| | - Lijie Dong
- Division of Chemical Metrology and Analytical Chemistry, National Institute of Metrology, Beijing, 100029, China
| | - Xueying Sheng
- State Key Laboratory of Heavy Oil Processing, College of Chemical Engineering and Environment, China University of Petroleum-Beijing, Beijing, 102249, China
| | - Jingbo Chao
- Division of Chemical Metrology and Analytical Chemistry, National Institute of Metrology, Beijing, 100029, China
| | - Sujuan Yu
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P. O. Box 2871, Beijing, 100085, China
| | - Jingfu Liu
- School of Environment, Hangzhou Institute for Advanced Study, UCAS, Hangzhou, 310024, China. .,State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P. O. Box 2871, Beijing, 100085, China. .,Institute of Environment and Health, Jianghan University, Wuhan, 430056, China.
| |
Collapse
|
3
|
Witecka A, Bogucka A, Yamamoto A, Máthis K, Krajňák T, Jaroszewicz J, Święszkowski W. In vitro degradation of ZM21 magnesium alloy in simulated body fluids. Mater Sci Eng C Mater Biol Appl 2016; 65:59-69. [PMID: 27157728 DOI: 10.1016/j.msec.2016.04.019] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/14/2015] [Revised: 03/04/2016] [Accepted: 04/06/2016] [Indexed: 11/21/2022]
Abstract
In vitro degradation behavior of squeeze cast (CAST) and equal channel angular pressed (ECAP) ZM21 magnesium alloy (2.0wt% Zn-0.98wt% Mn) was studied using immersion tests up to 4w in three different biological environments. Hanks' Balanced Salt Solution (Hanks), Earle's Balanced Salt Solution (Earle) and Eagle minimum essential medium supplemented with 10% (v/v) fetal bovine serum (E-MEM+10% FBS) were used to investigate the effect of carbonate buffer system, organic compounds and material processing on the degradation behavior of the ZM21 alloy samples. Corrosion rate of the samples was evaluated by their Mg(2+) ion release, weight loss and volume loss. In the first 24h, the corrosion rate sequence of the CAST samples was as following: Hanks>E-MEM+10% FBS>Earle. However, in longer immersion periods, the corrosion rate sequence was Earle>E-MEM+10% FBS≥Hanks. Strong buffering effect provided by carbonate buffer system helped to maintain the pH avoiding drastic increase of the corrosion rate of ZM21 in the initial stage of immersion. Organic compounds also contributed to maintain the pH of the fluid. Moreover, they adsorbed on the sample surface and formed an additional barrier on the insoluble salt layer, which was effective to retard the corrosion of CAST samples. In case of ECAP, however, this effect was overcome by the occurrence of strong localized corrosion due to the lower pH of the medium. Corrosion of ECAP samples was much greater than that of CAST, especially in Hanks, due to higher sensitivity of ECAP to localized corrosion and the presence of Cl(-). The present work demonstrates the importance of using an appropriate solution for a reliable estimation of the degradation rate of Mg-base degradable implants in biological environments, and concludes that the most appropriate solution for this purpose is E-MEM+10% FBS, which has the closest chemical composition to human blood plasma.
Collapse
|