Springer E, Cardoso PL, Strasser B, Bogner W, Preusser M, Widhalm G, Nittka M, Koerzdoerfer G, Szomolanyi P, Hangel G, Hainfellner JA, Marik W, Trattnig S. MR Fingerprinting-A Radiogenomic Marker for Diffuse Gliomas. Cancers (Basel) 2022; 14:cancers14030723. [PMID: 35158990 PMCID: PMC8833555 DOI: 10.3390/cancers14030723] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2021] [Revised: 01/22/2022] [Accepted: 01/28/2022] [Indexed: 11/16/2022] Open
Abstract
(1) Background: Advanced MR imaging (MRI) of brain tumors is mainly based on qualitative contrast images. MR Fingerprinting (MRF) offers a novel approach. The purpose of this study was to use MRF-derived T1 and T2 relaxation maps to differentiate diffuse gliomas according to isocitrate dehydrogenase (IDH) mutation. (2) Methods: Twenty-four patients with histologically verified diffuse gliomas (14 IDH-mutant, four 1p/19q-codeleted, 10 IDH-wildtype) were enrolled. MRF T1 and T2 relaxation times were compared to apparent diffusion coefficient (ADC), relative cerebral blood volume (rCBV) within solid tumor, peritumoral edema, and normal-appearing white matter (NAWM), using contrast-enhanced MRI, diffusion-, perfusion-, and susceptibility-weighted imaging. For perfusion imaging, a T2* weighted perfusion sequence with leakage correction was used. Correlations of MRF T1 and T2 times with two established conventional sequences for T1 and T2 mapping were assessed (a fast double inversion recovery-based MR sequence ('MP2RAGE') for T1 quantification and a multi-contrast spin echo-based sequence for T2 quantification). (3) Results: MRF T1 and T2 relaxation times were significantly higher in the IDH-mutant than in IDH-wildtype gliomas within the solid part of the tumor (p = 0.024 for MRF T1, p = 0.041 for MRF T2). MRF T1 and T2 relaxation times were significantly higher in the IDH-wildtype than in IDH-mutant gliomas within peritumoral edema less than or equal to 1cm adjacent to the tumor (p = 0.038 for MRF T1 mean, p = 0.010 for MRF T2 mean). In the solid part of the tumor, there was a high correlation between MRF and conventionally measured T1 and T2 values (r = 0.913, p < 0.001 for T1, r = 0.775, p < 0.001 for T2), as well as between MRF and ADC values (r = 0.813, p < 0.001 for T2, r = 0.697, p < 0.001 for T1). The correlation was weak between the MRF and rCBV values (r = -0.374, p = 0.005 for T2, r = -0.181, p = 0.181 for T1). (4) Conclusions: MRF enables fast, single-sequence based, multi-parametric, quantitative tissue characterization of diffuse gliomas and may have the potential to differentiate IDH-mutant from IDH-wildtype gliomas.
Collapse
Affiliation(s)
- Elisabeth Springer
- High-Field MR Centre, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, 1090 Vienna, Austria; (E.S.); (P.L.C.); (B.S.); (P.S.); (G.H.); (S.T.)
- Institute of Radiology, Hietzing Hospital, 1130 Vienna, Austria
| | - Pedro Lima Cardoso
- High-Field MR Centre, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, 1090 Vienna, Austria; (E.S.); (P.L.C.); (B.S.); (P.S.); (G.H.); (S.T.)
| | - Bernhard Strasser
- High-Field MR Centre, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, 1090 Vienna, Austria; (E.S.); (P.L.C.); (B.S.); (P.S.); (G.H.); (S.T.)
| | - Wolfgang Bogner
- High-Field MR Centre, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, 1090 Vienna, Austria; (E.S.); (P.L.C.); (B.S.); (P.S.); (G.H.); (S.T.)
- Correspondence: ; Tel.: +431-40-400-64710
| | - Matthias Preusser
- Division of Oncology, Department of Internal Medicine I, Medical University of Vienna, 1090 Vienna, Austria;
| | - Georg Widhalm
- Department of Neurosurgery, Medical University of Vienna, 1090 Vienna, Austria;
| | - Mathias Nittka
- Siemens Healthineers, 91052 Erlangen, Germany; (M.N.); (G.K.)
| | | | - Pavol Szomolanyi
- High-Field MR Centre, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, 1090 Vienna, Austria; (E.S.); (P.L.C.); (B.S.); (P.S.); (G.H.); (S.T.)
- Department of Imaging Methods, Institute of Measurement Science, Slovak Academy of Sciences, 84104 Bratislava, Slovakia
| | - Gilbert Hangel
- High-Field MR Centre, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, 1090 Vienna, Austria; (E.S.); (P.L.C.); (B.S.); (P.S.); (G.H.); (S.T.)
- Department of Neurosurgery, Medical University of Vienna, 1090 Vienna, Austria;
| | - Johannes A. Hainfellner
- Division of Neuropathology and Neurochemistry, Department of Neurology, Medical University of Vienna, 1090 Vienna, Austria;
| | - Wolfgang Marik
- Division of Neuroradiology and Musculoskeletal Radiology, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, 1090 Vienna, Austria;
| | - Siegfried Trattnig
- High-Field MR Centre, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, 1090 Vienna, Austria; (E.S.); (P.L.C.); (B.S.); (P.S.); (G.H.); (S.T.)
- Christian Doppler Laboratory for Clinical Molecular MR Imaging, Medical University of Vienna, 1090 Vienna, Austria
| |
Collapse
|
2
|
Sindi R, Wong YH, Yeong CH, Sun Z. Development of patient-specific 3D-printed breast phantom using silicone and peanut oils for magnetic resonance imaging. Quant Imaging Med Surg 2020; 10:1237-1248. [PMID: 32550133 DOI: 10.21037/qims-20-251] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Background Despite increasing reports of 3D printing in medical applications, the use of 3D printing in breast imaging is limited, thus, personalized 3D-printed breast model could be a novel approach to overcome current limitations in utilizing breast magnetic resonance imaging (MRI) for quantitative assessment of breast density. The aim of this study is to develop a patient-specific 3D-printed breast phantom and to identify the most appropriate materials for simulating the MR imaging characteristics of fibroglandular and adipose tissues. Methods A patient-specific 3D-printed breast model was generated using 3D-printing techniques for the construction of the hollow skin and fibroglandular region shells. Then, the T1 relaxation times of the five selected materials (agarose gel, silicone rubber with/without fish oil, silicone oil, and peanut oil) were measured on a 3T MRI system to determine the appropriate ones to represent the MR imaging characteristics of fibroglandular and adipose tissues. Results were then compared to the reference values of T1 relaxation times of the corresponding tissues: 1,324.42±167.63 and 449.27±26.09 ms, respectively. Finally, the materials that matched the T1 relaxation times of the respective tissues were used to fill the 3D-printed hollow breast shells. Results The silicone and peanut oils were found to closely resemble the T1 relaxation times and imaging characteristics of these two tissues, which are 1,515.8±105.5 and 405.4±15.1 ms, respectively. The agarose gel with different concentrations, ranging from 0.5 to 2.5 wt%, was found to have the longest T1 relaxation times. Conclusions A patient-specific 3D-printed breast phantom was successfully designed and constructed using silicone and peanut oils to simulate the MR imaging characteristics of fibroglandular and adipose tissues. The phantom can be used to investigate different MR breast imaging protocols for the quantitative assessment of breast density.
Collapse
Affiliation(s)
- Rooa Sindi
- Discipline of Medical Radiation Sciences, School of Molecular and Life Sciences, Curtin University, Perth, WA, Australia.,Radio-diagnostic and Medical Imaging Department, Medical Physics Section, King Fahd Armed Forces Hospital, Jeddah, Kingdom of Saudi Arabia
| | - Yin How Wong
- School of Medicine, Faculty of Health and Medical Sciences, Taylor's University, Subang Jaya, Selangor, Malaysia
| | - Chai Hong Yeong
- School of Medicine, Faculty of Health and Medical Sciences, Taylor's University, Subang Jaya, Selangor, Malaysia
| | - Zhonghua Sun
- Discipline of Medical Radiation Sciences, School of Molecular and Life Sciences, Curtin University, Perth, WA, Australia
| |
Collapse
|
3
|
Dehghani M, Do KQ, Magistretti P, Xin L. Lactate measurement by neurochemical profiling in the dorsolateral prefrontal cortex at 7T: accuracy, precision, and relaxation times. Magn Reson Med 2019; 83:1895-1908. [PMID: 31729080 DOI: 10.1002/mrm.28066] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2019] [Revised: 09/17/2019] [Accepted: 10/14/2019] [Indexed: 12/21/2022]
Abstract
PURPOSE This assesses the potential of measuring lactate in the human brain using three non-editing MRS methods at 7T and compares the accuracy and precision of the methods. METHODS 1 H MRS data were measured in the right dorsolateral prefrontal cortex using a semi-adiabatic spin-echo full-intensity acquired localized sequence with three different protocols: (I) TE = 16 ms, (II) TE = 110 ms, and (III) TE = 16 ms, TI = 300 ms. T1 and T2 relaxation times of lactate were also measured. Simulated spectra were generated for three protocols with known concentrations, using a range of spectral linewidths and SNRs to assess the effect of data quality on the measurement precision and accuracy. RESULTS Lactate was quantified in all three protocols with mean Cramér-Rao lower bound of 8% (I), 13% (II), and 7% (III). The T1 and T2 relaxation times of lactate were 1.9 ± 0.2 s and 94 ± 13 ms, respectively. Simulations predicted a spectral linewidth-associated underestimation of lactate measurement. Simulations, phantom and in vivo results showed that protocol II was most affected by this underestimation. In addition, the estimation error was insensitive to a broad range of spectral linewidth with protocol I. Within-session coefficient of variances of lactate were 6.1 ± 7.9% (I), 22.3 ± 12.3% (II), and 5.1 ± 5.4% (III), respectively. CONCLUSION We conclude that protocols I and III have the potential to measure lactate at 7T with good reproducibility, whereas the measurement accuracy and precision depend on spectral linewidth and SNR, respectively. Moreover, simulation is valuable for the optimization of measurement protocols in future study design and the correction for measurement bias.
Collapse
Affiliation(s)
- Masoumeh Dehghani
- Center for Psychiatric Neuroscience (CNP), Department of Psychiatry, Lausanne University Hospital-CHUV, Prilly-Lausanne, Switzerland
| | - Kim Q Do
- Center for Psychiatric Neuroscience (CNP), Department of Psychiatry, Lausanne University Hospital-CHUV, Prilly-Lausanne, Switzerland
| | - Pierre Magistretti
- Center for Psychiatric Neuroscience (CNP), Department of Psychiatry, Lausanne University Hospital-CHUV, Prilly-Lausanne, Switzerland.,BESE Division, King Abdullah University of Science and Technology, Thuwal, Saudi Arabia.,Brain Mind Institute, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Lijing Xin
- Animal Imaging and Technology Core (AIT), Center for Biomedical Imaging (CIBM), Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| |
Collapse
|
4
|
In E, Naguib H, Haider M. Mechanical stability analysis of carrageenan-based polymer gel for magnetic resonance imaging liver phantom with lesion particles. J Med Imaging (Bellingham) 2014; 1:035502. [PMID: 26158073 PMCID: PMC4478721 DOI: 10.1117/1.jmi.1.3.035502] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2014] [Accepted: 11/24/2014] [Indexed: 11/14/2022] Open
Abstract
Medical imaging is an effective technique used to detect and prevent disease in cancer research. To optimize medical imaging, a calibration medium or phantom with tissue-mimicking properties is required. Although the feasibility of various polymer gel materials has previously been studied, the stability of the gels' properties has not been investigated. In this study, we fabricated carrageenan-based polymer gel to examine the stability of its properties such as density, conductivity, permittivity, elastic modulus, and [Formula: see text] and [Formula: see text] relaxation times over six weeks. We fabricated eight samples with different carrageenan and agar concentrations and found that the density, elastic modulus, and compressive strength fluctuated with no specific pattern. The elastic modulus in sample 4 with 3 wt. % carrageenan and 1.5 wt. % agar fluctuated from 0.51 to 0.64 MPa in five weeks. The [Formula: see text] and [Formula: see text] relaxation times also varied by 23% to 29%. We believe that the fluctuation of these properties is related to the change in water content of the sample due to cycles of water expulsion and absorption in their containers. The fluctuation of the properties should be minimized to achieve accurate calibration over the shelf life of the phantom and to serve as the standard for quality assurance. Furthermore, a full liver phantom with spherical lesion particles was fabricated to demonstrate the potential for phantom production.
Collapse
Affiliation(s)
- Eunji In
- University of Toronto, Smart and Adaptive Polymer Laboratory, Department of Mechanical & Industrial Engineering, 5 King’s College Road, Toronto M5S 3G8, Canada
| | - Hani Naguib
- University of Toronto, Smart and Adaptive Polymer Laboratory, Department of Mechanical & Industrial Engineering, 5 King’s College Road, Toronto M5S 3G8, Canada
- University of Toronto, Department of Materials Science and Engineering, Wallberg Building, 184 College Street, Toronto M5S 3E4, Canada
- University of Toronto, The Institute of Biomaterials and Biomedical Engineering, 164 College Street, Toronto M5S 3G9, Canada
| | - Masoom Haider
- University of Toronto, Department of Radiology, 263 McCaul Street, Toronto M5T 1W7, Canada
| |
Collapse
|