1
|
Malloy DC, Côté MP. Multi-session transcutaneous spinal cord stimulation prevents chloride homeostasis imbalance and the development of hyperreflexia after spinal cord injury in rat. Exp Neurol 2024; 376:114754. [PMID: 38493983 DOI: 10.1016/j.expneurol.2024.114754] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2023] [Revised: 02/28/2024] [Accepted: 03/11/2024] [Indexed: 03/19/2024]
Abstract
Spasticity is a complex and multidimensional disorder that impacts nearly 75% of individuals with spinal cord injury (SCI) and currently lacks adequate treatment options. This sensorimotor condition is burdensome as hyperexcitability of reflex pathways result in exacerbated reflex responses, co-contractions of antagonistic muscles, and involuntary movements. Transcutaneous spinal cord stimulation (tSCS) has become a popular tool in the human SCI research field. The likeliness for this intervention to be successful as a noninvasive anti-spastic therapy after SCI is suggested by a mild and transitory improvement in spastic symptoms following a single stimulation session, but it remains to be determined if repeated tSCS over the course of weeks can produce more profound effects. Despite its popularity, the neuroplasticity induced by tSCS also remains widely unexplored, particularly due to the lack of suitable animal models to investigate this intervention. Thus, the basis of this work was to use tSCS over multiple sessions (multi-session tSCS) in a rat model to target spasticity after SCI and identify the long-term physiological improvements and anatomical neuroplasticity occurring in the spinal cord. Here, we show that multi-session tSCS in rats with an incomplete (severe T9 contusion) SCI (1) decreases hyperreflexia, (2) increases the low frequency-dependent modulation of the H-reflex, (3) prevents potassium-chloride cotransporter isoform 2 (KCC2) membrane downregulation in lumbar motoneurons, and (4) generally augments motor output, i.e., EMG amplitude in response to single pulses of tSCS, particularly in extensor muscles. Together, this work displays that multi-session tSCS can target and diminish spasticity after SCI as an alternative to pharmacological interventions and begins to highlight the underlying neuroplasticity contributing to its success in improving functional recovery.
Collapse
Affiliation(s)
- Dillon C Malloy
- Marion Murray Spinal Cord Research Center, Department of Neurobiology and Anatomy, Drexel University College of Medicine, Philadelphia, PA 19129, United States of America.
| | - Marie-Pascale Côté
- Marion Murray Spinal Cord Research Center, Department of Neurobiology and Anatomy, Drexel University College of Medicine, Philadelphia, PA 19129, United States of America.
| |
Collapse
|
2
|
Gordineer EA, Stokic DS, Krenn MJ. Distinguishing reflex from non-reflex responses elicited by transcutaneous spinal stimulation targeting the lumbosacral cord in healthy individuals. Exp Brain Res 2024:10.1007/s00221-024-06790-2. [PMID: 38416179 DOI: 10.1007/s00221-024-06790-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2023] [Accepted: 01/21/2024] [Indexed: 02/29/2024]
Abstract
Transcutaneous spinal stimulation (TSS) studies rely on the depolarization of afferent fibers to provide input to the spinal cord; however, this has not been routinely ascertained. Thus, we aimed to characterize the types of responses evoked by TSS and establish paired-pulse ratio cutoffs that distinguish posterior root reflexes, evoked by stimulation of afferent nerve fibers, from motor responses, evoked by stimulation of efferent nerve fibers. Twelve neurologically intact participants (six women) underwent unipolar TSS (cathode over T11-12 spinal processes, anode paraumbilically) while resting supine. In six participants, unipolar TSS was repeated 2-3 months later and also compared to a bipolar TSS configuration (cathode 2.5 cm below T11-12, anode 5 cm above cathode). EMG signals were recorded from 16 leg muscles. A paired-pulse paradigm was applied at interstimulus intervals (ISIs) of 25, 50, 100, 200, and 400 ms. Responses were categorized by three assessors into reflexes, motor responses, or their combination (mixed responses) based on the visual presence/absence of paired-pulse suppression across ISIs. The paired-pulse ratio that best discriminated between response types was derived for each ISI. These cutoffs were validated by repeating unipolar TSS 2-3 months later and with bipolar TSS. Unipolar TSS evoked only reflexes (90%) and mixed responses (10%), which were mainly recorded in the quadriceps muscles (25-42%). Paired-pulse ratios of 0.51 (25-ms ISI) and 0.47 (50-ms ISI) best distinguished reflexes from mixed responses (100% sensitivity, > 99.2% specificity). These cutoffs performed well in the repeated unipolar TSS session (100% sensitivity, > 89% specificity). Bipolar TSS exclusively elicited reflexes which were all correctly classified. These results can be utilized in future studies to ensure that the input to the spinal cord originates from the depolarization of large afferents. This knowledge can be applied to improve the design of future neurophysiological studies and increase the fidelity of neuromodulation interventions.
Collapse
Affiliation(s)
- Elizabeth A Gordineer
- School of Graduate Studies in the Health Sciences, Program in Neuroscience, University of Mississippi Medical Center, Jackson, MS, USA
- Center for Neuroscience and Neurological Recovery, Methodist Rehabilitation Center, Jackson, MS, USA
| | - Dobrivoje S Stokic
- Center for Neuroscience and Neurological Recovery, Methodist Rehabilitation Center, Jackson, MS, USA
| | - Matthias J Krenn
- Center for Neuroscience and Neurological Recovery, Methodist Rehabilitation Center, Jackson, MS, USA.
- Department of Neurosurgery, University of Mississippi Medical Center, 2500 N State St, Jackson, MS, 39216, USA.
| |
Collapse
|
3
|
Gravholt A, Pfenninger C, Grospretre S, Martin A, Lapole T. Do soleus responses to transcutaneous spinal cord stimulation show similar changes to H-reflex in response to Achilles tendon vibration? Eur J Appl Physiol 2024:10.1007/s00421-023-05406-x. [PMID: 38252303 DOI: 10.1007/s00421-023-05406-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2023] [Accepted: 12/17/2023] [Indexed: 01/23/2024]
Abstract
INTRODUCTION/PURPOSE Recently, the use of transcutaneous spinal cord stimulation (TSCS) has been proposed as a viable alternative to the H-reflex. The aim of the current study was to investigate to what extent the two modes of spinal cord excitability investigation would be similarly sensitive to the well-known vibration-induced depression. METHODS Fourteen healthy participants (8 men and 6 women; age: 26.7 ± 4.8 years) were engaged in the study. The right soleus H-reflex and TSCS responses were recorded at baseline (PRE), during right Achilles tendon vibration (VIB) and following 20 min of vibration exposure (POST-VIB). Care was taken to match H-reflex and TSCS responses amplitude at PRE and to maintain effective stimulus intensities constant throughout time points. RESULTS The statistical analysis showed a significant effect of time for the H-reflex, with VIB (13 ± 5% of maximal M-wave (Mmax) and POST-VIB (36 ± 4% of Mmax) values being lower than PRE-values (48 ± 6% of Mmax). Similarly, TSCS responses changed over time, VIB (9 ± 5% of Mmax) and POST-VIB (27 ± 5% of Mmax) values being lower than PRE-values (46 ± 6% of Mmax). Pearson correlation analyses revealed positive correlation between H-reflex and TSCS responses PRE-to-VIB changes, but not for PRE- to POST-VIB changes. CONCLUSION While the sensitivity of TSCS seems to be similar to the gold standard H-reflex to highlight the vibratory paradox, both responses showed different sensitivity to the effects of prolonged vibration, suggesting slightly different pathways may actually contribute to evoked responses of both stimulation modalities.
Collapse
Affiliation(s)
- Anders Gravholt
- Université Jean Monnet Saint-Etienne, Lyon 1, Université Savoie Mont-Blanc, Laboratoire Interuniversitaire de Biologie de la Motricité, 42023, Saint-Etienne, France
| | - Clara Pfenninger
- Université Jean Monnet Saint-Etienne, Lyon 1, Université Savoie Mont-Blanc, Laboratoire Interuniversitaire de Biologie de la Motricité, 42023, Saint-Etienne, France
| | - Sidney Grospretre
- C3S Laboratory (Culture, Sport, , Health and Society; EA 4660), Department Sport & Performance, University of Franche-Comté, Besançon, France
| | - Alain Martin
- Laboratoire INSERM U1093, Université de Bourgogne, Faculté des Sciences du Sport (UFR Staps), BP 27877, 21078, Dijon, France
| | - Thomas Lapole
- Université Jean Monnet Saint-Etienne, Lyon 1, Université Savoie Mont-Blanc, Laboratoire Interuniversitaire de Biologie de la Motricité, 42023, Saint-Etienne, France.
| |
Collapse
|
4
|
Laskin JJ, Waheed Z, Thorogood NP, Nightingale TE, Noonan VK. Spinal cord stimulation research in the restoration of motor, sensory and autonomic function for individuals living with spinal cord injuries: A scoping review. Arch Phys Med Rehabil 2022; 103:1387-1397. [PMID: 35202581 DOI: 10.1016/j.apmr.2022.01.161] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2021] [Revised: 01/26/2022] [Accepted: 01/28/2022] [Indexed: 11/18/2022]
Abstract
OBJECTIVE To describe the status of spinal cord stimulation (SCS) research for the improvement of motor, sensory and autonomic function for individuals living with a spinal cord injury (SCI). DATA SOURCES This scoping review identified original research published prior to March 31, 2021, via literature searches using Medline, EMBASE, PubMed, Science Direct, CINAHL, Sport Discus, Web of Science, as well as a targeted search for well-known principal investigators. Search terms included permutations of "spinal cord stimulation", "epidural spinal cord stimulation", "transcutaneous spinal cord stimulation", "magnetic spinal cord stimulation" and "neuromodulation". STUDY SELECTION Studies were included if they: 1) were in English, 2) presented original research on humans living with a SCI, and 3) investigated at least one of the three forms of SCS. DATA EXTRACTION Extracted data included: authors, publication year, participant characteristics, purpose, study design, stimulation (device, location, parameters,) primary outcomes, and adverse events. DATA SYNTHESIS As a scoping review the extracted data was tabulated and presented descriptively. Themes and gaps in the literature were identified and reported. Of the 5,754 articles screened, 103 articles were included (55 epidural, 36 transcutaneous and 12 magnetic). The primary research design was a case study or series with only a single randomized clinical trial. Motor recovery was the most common primary outcome for epidural and transcutaneous SCS studies whereas bowel and bladder outcomes were most common for magnetic. Seventy percent of the studies included 10 or fewer participants, and 18 articles documented at least one adverse event. Incomplete stimulation parameter descriptions were noted across many studies. No articles mentioned direct engagement of consumers or advocacy groups. CONCLUSION This review identified a need for more robust study designs, larger sample sizes, comparative studies, improved reporting of stimulation parameters, adverse event data, and alignment of outcomes with the priorities of the SCI community.
Collapse
Affiliation(s)
- James J Laskin
- Praxis Spinal Cord Institute, Vancouver, British Columbia, Canada; School of Physical Therapy and Rehabilitation Science, University of Montana, Missoula, Montana.
| | - Zeina Waheed
- Praxis Spinal Cord Institute, Vancouver, British Columbia, Canada
| | | | - Tom E Nightingale
- International Collaboration on Repair Discoveries, University of British Columbia, Vancouver, British Columbia, Canada; School of Sport, Exercise, and Rehabilitation Sciences, University of Birmingham, Birmingham, United Kingdom; Centre for Trauma Sciences Research, University of Birmingham, Edgbaston, Birmingham, United Kingdom
| | - Vanessa K Noonan
- Praxis Spinal Cord Institute, Vancouver, British Columbia, Canada; International Collaboration on Repair Discoveries, University of British Columbia, Vancouver, British Columbia, Canada
| |
Collapse
|
5
|
Havton LA, Christe KL, Edgerton VR, Gad PN. Noninvasive spinal neuromodulation to map and augment lower urinary tract function in rhesus macaques. Exp Neurol 2019; 322:113033. [PMID: 31400304 DOI: 10.1016/j.expneurol.2019.113033] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2018] [Revised: 07/15/2019] [Accepted: 08/06/2019] [Indexed: 12/25/2022]
Abstract
Dysfunction of the lower urinary tract (LUT) is prevalent in neurological disorders, including multiple sclerosis, stroke, spinal cord injury and neurodegenerative conditions. Common symptoms include urgency, incontinence, and urinary retention. Recent advances in neuromodulation have resulted in improved treatments for overactive bladder symptoms of urgency, frequency, and nocturia. However, there are presently no treatments available for the induction of voiding to overcome urinary retention. We demonstrate that transcutaneous spinal cord stimulation (TSCS), a non-invasive intervention, applied over the thoracolumbar spine in neurologically intact rhesus macaques can activate the LUT, including activation of the bladder detrusor muscle, the urethral sphincter and pelvic floor muscles. Urodynamic studies show improved voiding efficiency and decreased post-voiding residual volumes in the bladder, while maintaining coordinated activity in the detrusor and sphincter with physiologic detrusor peak pressure, contraction duration, and urine flow rate remaining unchanged. We conclude that TSCS may represent a novel approach to activate the LUT and enable voiding in select neurological conditions.
Collapse
|
6
|
Masugi Y, Sasaki A, Kaneko N, Nakazawa K. Remote muscle contraction enhances spinal reflexes in multiple lower-limb muscles elicited by transcutaneous spinal cord stimulation. Exp Brain Res 2019; 237:1793-1803. [PMID: 31053895 DOI: 10.1007/s00221-019-05536-9] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2018] [Accepted: 04/01/2019] [Indexed: 11/26/2022]
Abstract
Transcutaneous spinal cord stimulation (tSCS) is a useful technique for the clinical assessment of neurological disorders. However, the characteristics of the spinal cord circuits activated by tSCS are not yet fully understood. In this study, we examined whether remote muscle contraction enhances the spinal reflexes evoked by tSCS in multiple lower-limb muscles. Eight healthy men participated in the current experiment, which required them to grip a dynamometer as fast as possible after the presentation of an auditory cue. Spinal reflexes were evoked in multiple lower-limb muscles with different time intervals (50-400 ms) after the auditory signals. The amplitudes of the spinal reflexes in all the recorded leg muscles significantly increased at 50-250 ms after remote muscle activation onset. This suggests that remote muscle contraction simultaneously facilitates the spinal reflexes in multiple lower-limb muscles. In addition, eight healthy men performed five different tasks (i.e., rest, hand grip, pinch grip, elbow flexion, and shoulder flexion). Compared to control values recorded just before each task, the spinal reflexes evoked at 250 ms after the auditory signals were significantly enhanced by the above tasks except for the rest task. This indicates that such facilitatory effects are also induced by remote muscle contractions in different upper-limb areas. The present results demonstrate the existence of a neural interaction between remote upper-limb muscles and spinal reflex circuits activated by tSCS in multiple lower-limb muscles. The combination of tSCS and remote muscle contraction may be useful for the neurological examination of spinal cord circuits.
Collapse
Affiliation(s)
- Yohei Masugi
- Department of Life Sciences, Graduate School of Arts and Sciences, The University of Tokyo, 3-8-1 Komaba, Meguro-ku, Tokyo, 153-8902, Japan
- Institute of Sports Medicine and Science, Tokyo International University, 2509 Matoba, Kawagoe-shi, Saitama, 350-1198, Japan
| | - Atsushi Sasaki
- Department of Life Sciences, Graduate School of Arts and Sciences, The University of Tokyo, 3-8-1 Komaba, Meguro-ku, Tokyo, 153-8902, Japan
| | - Naotsugu Kaneko
- Department of Life Sciences, Graduate School of Arts and Sciences, The University of Tokyo, 3-8-1 Komaba, Meguro-ku, Tokyo, 153-8902, Japan
| | - Kimitaka Nakazawa
- Department of Life Sciences, Graduate School of Arts and Sciences, The University of Tokyo, 3-8-1 Komaba, Meguro-ku, Tokyo, 153-8902, Japan.
| |
Collapse
|
7
|
Chen L, Ke A, Zhang P, Gao Z, Zou X, He J. Bioheat transfer model of transcutaneous spinal cord stimulation-induced temperature changes. PeerJ 2018; 6:e4921. [PMID: 29888135 PMCID: PMC5991303 DOI: 10.7717/peerj.4921] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2018] [Accepted: 05/17/2018] [Indexed: 11/20/2022] Open
Abstract
Transcutaneous spinal cord stimulation (tSCS) has been extensively studied due to its promising application in motor function restoration. Many previous studies have explored both the essential mechanism of action and the methods for determining optimal stimulation parameters. In contrast, the bioheat transfer analysis of tSCS therapy has not been investigated to the same extent, despite widely existing, and being of great significance in assuring a stable and thermally safe treatment. In this paper, we concentrated on the thermal effects of tSCS using a finite element-based method. By coupling the electric field and bioheat field, systematic finite element simulations were performed on a human spinal cord model to survey the influence of anatomical structures, blood perfusion, and stimulation parameters on temperature changes for the first time. The results show that tSCS-induced temperature rise mainly occurs in the skin and fat layers and varies due to individual differences. The current density distribution along with the interactions of multiple biothermal effects synthetically determines the thermal status of the whole spinal cord model. Smaller stimulation electrodes have a higher risk of thermal damage when compared with larger electrodes. Increasing the stimulation intensity will result in more joule heat accumulation, hence an increase in the temperature. Among all configurations in this study that simulated the clinical tSCS protocols, the temperature rise could reach up to 9.4 °C on the skin surface depending on the stimulation parameters and tissue blood perfusion.
Collapse
Affiliation(s)
- Luyao Chen
- School of Optical and Electronic Information, Huazhong University of Science and Technology, Wuhan, China
- Neural Interface and Rehabilitation Technology Research Center, School of Automation, Huazhong University of Science and Technology, Wuhan, China
- Collaborative Innovation Center for Brain Science, Huazhong University of Science and Technology, Wuhan, China
| | - Ang Ke
- Neural Interface and Rehabilitation Technology Research Center, School of Automation, Huazhong University of Science and Technology, Wuhan, China
- Collaborative Innovation Center for Brain Science, Huazhong University of Science and Technology, Wuhan, China
| | - Peng Zhang
- Neural Interface and Rehabilitation Technology Research Center, School of Automation, Huazhong University of Science and Technology, Wuhan, China
- Collaborative Innovation Center for Brain Science, Huazhong University of Science and Technology, Wuhan, China
| | - Zhaolong Gao
- Neural Interface and Rehabilitation Technology Research Center, School of Automation, Huazhong University of Science and Technology, Wuhan, China
- Collaborative Innovation Center for Brain Science, Huazhong University of Science and Technology, Wuhan, China
| | - Xuecheng Zou
- School of Optical and Electronic Information, Huazhong University of Science and Technology, Wuhan, China
| | - Jiping He
- Neural Interface and Rehabilitation Technology Research Center, School of Automation, Huazhong University of Science and Technology, Wuhan, China
- Collaborative Innovation Center for Brain Science, Huazhong University of Science and Technology, Wuhan, China
- Advanced Innovation Center for Intelligent Robots and Systems, Beijing Institute of Technology, Beijing, China
| |
Collapse
|
8
|
Nakagawa K, Masugi Y, Saito A, Obata H, Nakazawa K. Influence of motor imagery on spinal reflex excitability of multiple muscles. Neurosci Lett 2018; 668:55-59. [PMID: 29329907 DOI: 10.1016/j.neulet.2018.01.015] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2017] [Accepted: 01/07/2018] [Indexed: 11/25/2022]
Abstract
The effects of motor imagery on spinal reflexes such as the H-reflex are unclear. One reason for this is that the muscles that can be used to record spinal reflexes are limited to traditional evoking methods Recently, transcutaneous spinal cord stimulation has been used for inducing spinal reflexes from multiple muscles and we aimed to examine the effect of motor imagery on spinal reflexes from multiple muscles. Spinal reflexes evoked by transcutaneous spinal cord stimulation were recorded from six muscles from lower limbs during motor imagery of right wrist extension and ankle plantarflexion with maximum isometric contraction. During both imaginary tasks, facilitation of spinal reflexes was detected in the ankle ipsilateral plantarflexor and dorsiflexor muscles, but not in thigh, toe or contralateral lower limb muscles. These results suggest that motor imagery of isometric contraction facilitates spinal reflex excitability in muscles of the ipsilateral lower leg and the facilitation does not correspond to the imaginary involved muscles.
Collapse
Affiliation(s)
- Kento Nakagawa
- Graduate School of Arts and Sciences, The University of Tokyo, Komaba, Meguro-ku, Tokyo, Japan; Japan Society for the Promotion of Science, Japan.
| | - Yohei Masugi
- Institute of Sports Medicine and Science, Tokyo International University, Matoba, Kawagoe-shi, Saitama, Japan
| | - Akira Saito
- Graduate School of Arts and Sciences, The University of Tokyo, Komaba, Meguro-ku, Tokyo, Japan; Japan Society for the Promotion of Science, Japan
| | - Hiroki Obata
- Department of Humanities and Social Sciences, Institute of Liberal Arts, Kyushu Institute of Technology, Sensui-cho, Tobata-ku, Kitakyushu-shi, Fukuoka, Japan
| | - Kimitaka Nakazawa
- Graduate School of Arts and Sciences, The University of Tokyo, Komaba, Meguro-ku, Tokyo, Japan
| |
Collapse
|
9
|
Masugi Y, Kawashima N, Inoue D, Nakazawa K. Effects of movement-related afferent inputs on spinal reflexes evoked by transcutaneous spinal cord stimulation during robot-assisted passive stepping. Neurosci Lett 2016; 627:100-6. [PMID: 27235576 DOI: 10.1016/j.neulet.2016.05.047] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2016] [Revised: 05/12/2016] [Accepted: 05/24/2016] [Indexed: 11/18/2022]
Abstract
Studies of robot-assisted passive stepping paradigms have reported that movement-related afferent inputs strongly inhibit the excitability of the Hoffmann (H) reflex in the soleus (Sol) during walking. However, it is unknown if movement-related afferent inputs have the same effect on the excitability of spinal reflexes in the other lower-limb muscles that are involved in normal walking in healthy subjects. The aim of this study was to examine the effects of movement-related afferent inputs on the spinal reflexes in lower-limb muscles during walking. Spinal reflexes that were elicited by transcutaneous spinal cord stimulation (tSCS) were recorded during passive air standing and air stepping at three stepping velocities (stride frequencies: 14, 25, and 36 strides/min). The amplitude of the spinal reflexes was reduced in most of the recorded muscles during passive air stepping compared with air standing. Furthermore, in the Sol and lateral gastrocnemius, the amplitude of the reflexes during air stepping significantly decreased as stride frequency increased. These results demonstrate that movement-related afferent inputs inhibit spinal reflexes in the Sol and other lower-limb muscles during walking.
Collapse
Affiliation(s)
- Yohei Masugi
- Department of Rehabilitation for Movement Functions, Research Institute of the National Rehabilitation Center for Persons with Disabilities, 4-1 Namiki, Tokorozawa, Saitama 359-8555, Japan.
| | - Noritaka Kawashima
- Department of Rehabilitation for Movement Functions, Research Institute of the National Rehabilitation Center for Persons with Disabilities, 4-1 Namiki, Tokorozawa, Saitama 359-8555, Japan
| | - Daisuke Inoue
- Department of Life Sciences, Graduate School of Arts and Sciences, The University of Tokyo, 3-8-1 Komaba, Meguro-ku, Tokyo 153-8902, Japan
| | - Kimitaka Nakazawa
- Department of Life Sciences, Graduate School of Arts and Sciences, The University of Tokyo, 3-8-1 Komaba, Meguro-ku, Tokyo 153-8902, Japan
| |
Collapse
|
10
|
Sayenko DG, Atkinson DA, Floyd TC, Gorodnichev RM, Moshonkina TR, Harkema SJ, Edgerton VR, Gerasimenko YP. Effects of paired transcutaneous electrical stimulation delivered at single and dual sites over lumbosacral spinal cord. Neurosci Lett 2015; 609:229-34. [PMID: 26453766 DOI: 10.1016/j.neulet.2015.10.005] [Citation(s) in RCA: 48] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2015] [Revised: 09/04/2015] [Accepted: 10/01/2015] [Indexed: 01/03/2023]
Abstract
It was demonstrated previously that transcutaneous electrical stimulation of multiple sites over the spinal cord is more effective in inducing robust locomotor behavior as compared to the stimulation of single sites alone in both animal and human models. To explore the effects and mechanisms of interactions during multi-site spinal cord stimulation we delivered transcutaneous electrical stimulation to the single or dual locations over the spinal cord corresponding to approximately L2 and S1 segments. Spinally evoked motor potentials in the leg muscles were investigated using single and paired pulses of 1ms duration with conditioning-test intervals (CTIs) of 5 and 50ms. We observed considerable post-stimulation modulatory effects which depended on CTIs, as well as on whether the paired stimuli were delivered at a single or dual locations, the rostro-caudal relation between the conditioning and test stimuli, and on the muscle studied. At CTI-5, the paired stimulation delivered at single locations (L2 or S1) provided strong inhibitory effects, evidenced by the attenuation of the compound responses as compared with responses from either single site. In contrast, during L2-S1 paradigm, the compound responses were potentiated. At CTI-50, the magnitude of inhibition did not differ among paired stimulation paradigms. Our results suggest that electrical stimuli delivered to dual sites over the lumbosacral enlargement in rostral-to-caudal order, may recruit different populations of motor neurons initially through projecting sensory and intraspinal connections and then directly, resulting in potentiation of the compound spinally evoked motor potentials. The interactive and synergistic effects indicate multi-segmental convergence of descending and ascending influences on the neuronal circuitries during electrical spinal cord stimulation.
Collapse
|