1
|
Filipovský J, Seidlerová J, Ceral J, Vysočanová P, Špác J, Souček M, Řiháček I, Mateřánková M, König P, Rosolová H. A multicentre study on unattended automated office blood pressure measurement in treated hypertensive patients. Blood Press 2018; 27:188-193. [PMID: 29334262 DOI: 10.1080/08037051.2018.1425606] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
AIMS Unattended automated office blood pressure (uAutoOBP) may eliminate white-coat effect. In the present study, we studied its relationships to attended office blood pressure (BP) and ambulatory BP monitoring (ABPM). MATERIAL AND METHODS Stable treated hypertensive subjects were examined in four Czech academic hypertension centres. uAutoOBP was measured with the BP Tru device; attended BP was measured six times: three times with auscultatory method (AuscOBP) by the physician followed optionally by three oscillometric measurements (OscOBP). ABPM was performed within one week from the clinical visit. RESULTS Data on 172 subjects aged 63.7 ± 12.4 years with AuscOBP 127.6 ± 12.1/77.6 ± 10.0 mm Hg are reported. uAutoOBP was by 8.5 ± 9.0/3.0 ± 6.1 mm Hg lower than AuscOBP. The AuscOBP-uAutoOBP difference increased with the AuscOBP level and it did not depend on any other factor. OscOBP differed by 8.6 ± 8.6/1.9 ± 5.7 mm Hg from uAutoOBP. 24-hour mean BP was by 4.2 ± 12.1/3.5 ± 7.8 mm Hg lower than AuscOBP and by 4.3 ± 11.0/0.5 ± 6.9 mm Hg higher than uAutoOBP; the correlation coefficients of 24-hour mean BP with AuscOBP and with uAutoOBP did not differ (p for difference ≥.13). In the lowest BP group (systolic AuscOBP <120 mm Hg or diastolic AuscOBP <70 mm Hg), both AuscOBP and uAutoOBP were lower than 24-hour mean BP, while in the highest BP group (systolic AuscOBP ≥140 mm Hg or diastolic AuscOBP ≥90 mm Hg), they were higher. CONCLUSIONS Compared to uAutoOBP, attended BP measurement gives higher values, both when measured with auscultatory or oscillometric method. Inter-individual variability of AutoOBP - uAuscOBP difference, as well of uAutoOBP - ABPM difference, is large. We did not prove that uAutoOBP would be associated to 24-hour ambulatory BP more closely than attended BP.
Collapse
Affiliation(s)
- Jan Filipovský
- a Internal Department II, Faculty of Medicine in Pilsen , Charles University , Plzen , Czech Republic.,b Biomedical Centre, Faculty of Medicine in Pilsen , Charles University , Plzen , Czech Republic
| | - Jitka Seidlerová
- a Internal Department II, Faculty of Medicine in Pilsen , Charles University , Plzen , Czech Republic.,b Biomedical Centre, Faculty of Medicine in Pilsen , Charles University , Plzen , Czech Republic
| | - Jiří Ceral
- c Department of Cardiology , Faculty Hospital Hradec Králové , Hradec Králové , Czech Republic
| | - Petra Vysočanová
- d Department of Cardiology , Faculty Hospital Bohunice , Brno , Czech Republic
| | - Jiří Špác
- e 2nd Department of Internal Medicine , Faculty of Medicine, Masaryk University, St. Anne's University Hospital Brno , Brno , Czech Republic
| | - Miroslav Souček
- e 2nd Department of Internal Medicine , Faculty of Medicine, Masaryk University, St. Anne's University Hospital Brno , Brno , Czech Republic
| | - Ivan Řiháček
- e 2nd Department of Internal Medicine , Faculty of Medicine, Masaryk University, St. Anne's University Hospital Brno , Brno , Czech Republic
| | - Markéta Mateřánková
- a Internal Department II, Faculty of Medicine in Pilsen , Charles University , Plzen , Czech Republic
| | - Petr König
- a Internal Department II, Faculty of Medicine in Pilsen , Charles University , Plzen , Czech Republic
| | - Hana Rosolová
- a Internal Department II, Faculty of Medicine in Pilsen , Charles University , Plzen , Czech Republic
| |
Collapse
|