1
|
Tsunemi Y, Otsuka A, Nonaka Y. Receipt survey of prescription continuation rates for patients with onychomycosis and web-based survey of dermatologists on prescribing policies for onychomycosis therapeutics. J Dermatol 2024; 51:526-531. [PMID: 38279193 DOI: 10.1111/1346-8138.17110] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2023] [Revised: 12/14/2023] [Accepted: 12/26/2023] [Indexed: 01/28/2024]
Abstract
Onychomycosis can be treated with topical and oral medications. However, it is important to appropriately select these medications according to the type and severity of the disease and ensure treatment is continued for the recommended duration. In Japan, treatment options for onychomycosis have increased in recent years. Moreover, in 2019, the guidelines for dermatomycosis treatment were revised. In this study, we conducted a receipt survey to clarify the actual treatment status of onychomycosis cases as indicated by the continuation rates of prescribed treatment drugs, together with a web-based survey to ascertain the prescribing policy of dermatologists regarding drugs for onychomycosis treatment. In agreement with past surveys, this receipt survey showed that the prescription continuation rate for oral medications was higher than that for topical medications. The 1-year prescription continuation rate for topical onychomycosis medications was found to be low (<10%). The web-based survey showed that the percentage of physicians who prescribed oral medications as their first choice increased by approximately 10% for each disease type, compared with the results of the previous survey conducted around 7 years ago. However, the study also confirmed that topical drugs are still prescribed for some disease types for which oral drugs are better suited. To ensure complete cure without patient drop-out, oral drugs with a high probability of achieving complete cure and a high continuation rate should be prescribed for patients with onychomycosis.
Collapse
Affiliation(s)
- Yuichiro Tsunemi
- Department of Dermatology, Saitama Medical University, Saitama, Japan
| | - Atsushi Otsuka
- Department of Dermatology, Faculty of Medicine, Kindai University, Osaka, Japan
| | - Yusuke Nonaka
- Medical Affairs Department, Sato Pharmaceutical Co., Ltd., Tokyo, Japan
| |
Collapse
|
2
|
Laporte M, Marcelino AC, da Cunha Pereira P, Espejo-Arce X, Juliato CT, Bahamondes L. Effectiveness and continuation rates of the etonogestrel-subdermal contraceptive implant versus short-acting contraceptive methods offered at no cost in Campinas, Brazil. Int J Gynaecol Obstet 2024. [PMID: 38328989 DOI: 10.1002/ijgo.15415] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2023] [Revised: 12/27/2023] [Accepted: 01/25/2024] [Indexed: 02/09/2024]
Abstract
OBJECTIVES To compare the efficacy, reasons for discontinuation and continuation rates of the etonogestrel (ENG)-subdermal contraceptive implant when offered at no cost, and the basis of free choice versus short-acting reversible contraceptive (SARC) methods including combined oral contraceptives (COCs), once-a-month injectables, vaginal ring, and patch. METHODS We conducted a prospective study at the University of Campinas, Brazil, involving women aged 18 to 40 years. They were counseled on various contraceptive methods before entering the study and followed up every 3 months for up to 24 months. Satisfaction was assessed using a Likert scale. Survival rates were estimated using the Kaplan-Meier test, and curve comparisons were performed using the log-rank test. RESULTS We enrolled 609 women including 358/609 women (58.8%) who chose the ENG-implant and 251/609 (41.2%) who chose SARC methods. Contraceptive failure and all other reasons for discontinuation were significantly higher in SARC users compared to the ENG-implant users (P < 0.001 and P = 0.002, respectively). The continuation rate was higher among ENG-implant users (89.9% and 75.4%) compared to SARC methods users (27.2% and 15.9%) up to 1 and 2 years after study initiation, respectively. Satisfaction was high in both groups (>82%). CONCLUSIONS The ENG-implant showed higher contraceptive effectiveness and higher continuation rates than SARC methods up to 2 years after study initiation. Furthermore, users from both groups were highly satisfied with their contraceptive. The main reason for discontinuing use of the ENG-implant was bothersome uterine bleeding, while for SARC methods it was for personal reasons.
Collapse
Affiliation(s)
- Montas Laporte
- Department of Obstetrics and Gynecology, Faculty of Medical Sciences, University of Campinas, Campinas, São Paulo, Brazil
| | - Ana C Marcelino
- Department of Obstetrics and Gynecology, Faculty of Medical Sciences, University of Campinas, Campinas, São Paulo, Brazil
| | - Paula da Cunha Pereira
- Department of Obstetrics and Gynecology, Faculty of Medical Sciences, University of Campinas, Campinas, São Paulo, Brazil
| | - Ximena Espejo-Arce
- Department of Obstetrics and Gynecology, Faculty of Medical Sciences, University of Campinas, Campinas, São Paulo, Brazil
| | - Cassia T Juliato
- Department of Obstetrics and Gynecology, Faculty of Medical Sciences, University of Campinas, Campinas, São Paulo, Brazil
| | - Luis Bahamondes
- Department of Obstetrics and Gynecology, Faculty of Medical Sciences, University of Campinas, Campinas, São Paulo, Brazil
| |
Collapse
|
3
|
Brull E, Machado HC, Bahamondes L, Juliato CRT. Expulsion and continuation rates of the 52 mg levonorgestrel intrauterine system in adolescents and adult women. EUR J CONTRACEP REPR 2023:1-6. [PMID: 37335234 DOI: 10.1080/13625187.2023.2215366] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Revised: 05/12/2023] [Accepted: 05/13/2023] [Indexed: 06/21/2023]
Abstract
OBJECTIVE To compare the continuation rates, expulsion, and other reasons for discontinuation of the hormonal intrauterine device with 52 mg of levonorgestrel (52 mg LNG-IUD) in adolescents and adult women. METHODS We conducted a retrospective cohort study that included 393 women in whom we placed a 52 mg LNG-IUD and followed up to 5 years. We created two retrospective cohorts, one with 131 adolescents (aged between 12 and 19 years) and the other with 262 women aged ≥20 years. Each adolescent was paired with two adult women who had the same parity and who had a 52 mg LNG-IUD inserted on the same day. We used the Mann-Whitney test to compare numerical variables in both groups, the Kaplan-Meier method, and the log-rank test to compare the continuation, expulsion and other reasons for IUD discontinuation of the two groups. RESULTS Age of the adolescents and adult women were mean ± SD 18.1 (±1.1) and 31 (±6.8) years, respectively (p = 0.015). Continuation rates by the fifth year of use were 55.6/100 women-years (W-Y) and 70.3/100 W-Y among adolescents and adult women (p = 0.106); and expulsion rates were 8.4/100 and 6.0/100 W-Y, respectively (p = 0.463). Adolescents had a lower continuation rate during 3 to 5 years of follow-up (p = 0.011) and a high rate of removals due to bleeding/pain (18.5 ± 5.7/100 W-Y vs 6.4/100 ± 2.1 W-Y, p = 0.039). CONCLUSION Adolescents who used the 52 mg LNG-IUD showed a lower continuation rate 3-5 years after device placement than adult women. The expulsion rates were similar in both groups.
Collapse
Affiliation(s)
- Eliza Brull
- Department of Obstetrics and Gynecology, Faculty of Medical Sciences, University of Campinas (UNICAMP), Campinas, Brazil
| | - Helymar C Machado
- Department of Obstetrics and Gynecology, Faculty of Medical Sciences, University of Campinas (UNICAMP), Campinas, Brazil
| | - Luis Bahamondes
- Department of Obstetrics and Gynecology, Faculty of Medical Sciences, University of Campinas (UNICAMP), Campinas, Brazil
| | - Cássia R T Juliato
- Department of Obstetrics and Gynecology, Faculty of Medical Sciences, University of Campinas (UNICAMP), Campinas, Brazil
| |
Collapse
|
4
|
Westvik-Johari K, Håberg SE, Lawlor DA, Romundstad LB, Bergh C, Wennerholm UB, Gissler M, Henningsen AKA, Tiitinen A, Pinborg A, Opdahl S. The challenges of selective fertility and carryover effects in within-sibship analyses: the effect of assisted reproductive technology on perinatal mortality as an example. Int J Epidemiol 2023; 52:403-413. [PMID: 36715050 PMCID: PMC10266759 DOI: 10.1093/ije/dyad003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Accepted: 01/11/2023] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND Within-sibship analyses show lower perinatal mortality after assisted reproductive technology (ART) compared with natural conception (NC), a finding that appears biologically unlikely. We investigated whether this may be attributed to bias from selective fertility and carryover effects. METHODS Using data from national registries in Denmark (1994-2014), Finland (1990-2014) and Norway and Sweden (1988-2015), we studied 5 722 826 singleton pregnancies, including 119 900 ART-conceived and 37 590 exposure-discordant sibships. Perinatal mortality at the population level and within sibships was compared using multilevel logistic regression with random and fixed intercepts, respectively. We estimated selective fertility as the proportion of primiparous women with and without perinatal loss who had a second delivery, and carryover effects through bidirectional and crosswise associations. RESULTS Population analysis showed higher perinatal mortality among ART conception compared with NC (odds ratio 1.21, 95% CI 1.13 to 1.30), whereas within-sibship analysis showed the opposite (OR 0.36, 95% CI 0.31 to 0.43). Primiparous women with perinatal loss were more likely to give birth again (selective fertility) and to use ART in this subsequent pregnancy (carryover effects), resulting in strong selection of double-discordant sibships with death of the naturally conceived and survival of the ART-conceived sibling. After controlling for conception method and outcome in the first pregnancy, ART was not consistently associated with perinatal mortality in the second pregnancy. CONCLUSIONS Whereas population estimates may be biased by residual confounding, within-sibship estimates were biased by selective fertility and carryover effects. It remains unclear whether ART conception contributes to perinatal mortality.
Collapse
Affiliation(s)
- Kjersti Westvik-Johari
- Department of Fertility, Women and Children’s Centre, St Olavs Hospital, Trondheim, Norway
- Department of Public Health and Nursing, Norwegian University of Science and Technology, Trondheim, Norway
| | - Siri E Håberg
- Centre for Fertility and Health, Norwegian Institute of Public Health, Oslo, Norway
| | - Deborah A Lawlor
- Centre for Fertility and Health, Norwegian Institute of Public Health, Oslo, Norway
- MRC Integrative Epidemiology Unit at the University of Bristol, Bristol, UK
- Population Health Science, Bristol Medical School, Bristol, UK
- NIHR Bristol Biomedical Research Centre, Bristol, UK
| | - Liv Bente Romundstad
- Centre for Fertility and Health, Norwegian Institute of Public Health, Oslo, Norway
- Spiren Fertility Clinic, Trondheim, Norway
| | - Christina Bergh
- Department of Obstetrics and Gynaecology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Ulla-Britt Wennerholm
- Department of Obstetrics and Gynaecology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Mika Gissler
- Department of Knowledge Brokers, THL Finnish Institute for Health and Welfare, Helsinki, Finland
- Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden
- Academic Primary Health Care Centre, Region Stockholm, Stockholm, Sweden
| | | | - Aila Tiitinen
- Department of Obstetrics and Gynaecology, Helsinki University Hospital and University of Helsinki, Helsinki, Finland
| | - Anja Pinborg
- Fertility Clinic, Copenhagen University Hospital, Rigshospitalet, Copenhagen, Denmark
| | - Signe Opdahl
- Department of Public Health and Nursing, Norwegian University of Science and Technology, Trondheim, Norway
| |
Collapse
|
5
|
Ayano M, Kimoto Y, Mitoma H, Akahoshi M, Ono N, Arinobu Y, Akashi K, Horiuchi T, Niiro H. Comparative efficacy and safety of mizoribine and mycophenolate mofetil for treating systemic lupus erythematosus: a retrospective cohort study. Ther Adv Musculoskelet Dis 2022; 14:1759720X221096367. [PMID: 35586513 PMCID: PMC9109492 DOI: 10.1177/1759720x221096367] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Accepted: 04/01/2022] [Indexed: 12/11/2022] Open
Abstract
Background Mizoribine (MZR) is an immunosuppressive agent that selectively inhibits inosine monophosphate dehydrogenase; its actions are considerably similar to those of mycophenolate mofetil (MMF). This study aimed to clarify whether MZR can be a good treatment option for systemic lupus erythematosus (SLE) and to compare the efficacy and safety of MZR and MMF in patients with active SLE. Methods We retrospectively compared the efficacy, continuation rate, and safety of MZR (52 patients) and MMF (31 patients) after adjusting for stabilized inverse probability of treatment weighting based on propensity scores. The efficacy endpoints were as follows: cumulative incidence of lupus low disease activity state (LLDAS) or remission attainment and flares and change in prednisolone dose over 2 years. Drug continuation rates were defined as the time from drug initiation to discontinuation for any cause, owing to the lack of efficacy, or owing to adverse events. The safety endpoint was the frequency of adverse events. Results Overall, 25 (48.1%) and 13 (25.0%) patients in the MZR group and 18 (58.1%) and 15 (48.3%) in the MMF group achieved LLDAS and remission during the follow-up period, respectively; thus, the cumulative incidence of LLDAS and remission attainment of the two groups was similar after adjustment. Prednisolone dose was steadily reduced in both the groups, and the change in prednisolone dose was nearly identical between the two groups. Drug discontinuation rate due to adverse events and the frequency of all adverse events and infections were higher in the MMF group than in the MZR group, albeit without significance after adjustment. Conclusion MZR is as effective as MMF in controlling SLE activity. The adverse events of MZR, whose profile differs from MMF, are comparable to or less than those of MMF. MZR may be a valuable option as an immunosuppressive agent for SLE, as well as MMF.
Collapse
Affiliation(s)
- Masahiro Ayano
- Department of Medicine and Biosystemic Science,
Kyushu University Graduate School of Medical Sciences, 3-1-1 Maidashi,
Higashi-ku, Fukuoka 812-8582, Japan
- Department of Cancer Stem Cell Research, Kyushu
University Graduate School of Medical Sciences, Fukuoka, Japan
| | - Yasutaka Kimoto
- Department of Internal Medicine, Kyushu
University Beppu Hospital, Beppu, Japan
| | - Hiroki Mitoma
- Department of Medicine and Biosystemic Science,
Kyushu University Graduate School of Medical Sciences, Fukuoka, Japan
| | - Mitsuteru Akahoshi
- Department of Medicine and Biosystemic Science,
Kyushu University Graduate School of Medical Sciences, Fukuoka, Japan
- Department of Rheumatology, Saga University
Hospital, Saga, Japan
| | - Nobuyuki Ono
- Department of Medicine and Biosystemic Science,
Kyushu University Graduate School of Medical Sciences, Fukuoka, Japan
| | - Yojiro Arinobu
- Department of Medicine and Biosystemic Science,
Kyushu University Graduate School of Medical Sciences, Fukuoka, Japan
| | - Koichi Akashi
- Department of Medicine and Biosystemic Science,
Kyushu University Graduate School of Medical Sciences, Fukuoka, Japan
| | - Takahiko Horiuchi
- Department of Internal Medicine, Kyushu
University Beppu Hospital, Beppu, Japan
| | - Hiroaki Niiro
- Department of Medical Education, Kyushu
University Graduate School of Medical Sciences, Fukuoka, Japan
| |
Collapse
|
6
|
Abstract
Objective We investigated the continuation rate, safety and efficacy of treatment with hydroxychloroquine (HCQ) in a retrospective cohort of systemic lupus erythematosus (SLE) in a Japanese municipal hospital. Methods All of the patients with SLE who started treatment with HCQ were included in this study. A retrospective chart review was performed. Our primary outcomes were the continuation rate of HCQ treatment for 1 year and adverse events (AEs) during the treatment. We also investigated the efficacy of HCQ treatment in cases in which treatment with immunosuppressive therapies remained unchanged for the preceding six months. Results Forty-seven patients with SLE were included in this study. Twenty-five patients (53.2%) had AEs. Eleven (64.7%) of the 17 patients who tried the readministration of HCQ could continue HCQ treatment. The continuation rate of HCQ for a period of 1 year was 78.3% (36 of 46 patients). The development of cutaneous lesions was the most frequent adverse event (25.5%) followed by gastrointestinal symptoms (8.5%). In the 16 cases in which the immunosuppressive therapies remained unchanged for at least six months prior to starting HCQ treatment, the SLE disease activity index, anti-DNA antibody, immune complex, and serum complement activity significantly decreased over a period of 1 year, while the prednisolone dose significantly decreased. Conclusion The continuation rate of HCQ treatment was high in an SLE cohort of a Japanese municipal hospital. Although more than half of the patients experienced AEs, the readministration of HCQ was often successful. HCQ treatment provided benefits regarding the clinical and immunological findings in Japanese patients with SLE, which would likely lead to glucocorticoid tapering.
Collapse
Affiliation(s)
- Yohei Hosokawa
- Department of Rheumatology, Hiroshima City Hiroshima Citizens Hospital, Japan
| | - Hiroshi Oiwa
- Department of Rheumatology, Hiroshima City Hiroshima Citizens Hospital, Japan
| |
Collapse
|
7
|
Izhar R, Husain S, Tahir MA, Husain S. Femiject, a once-a-month combined injectable contraceptive: experience from Pakistan. EUR J CONTRACEP REPR 2020; 25:359-364. [PMID: 32757796 DOI: 10.1080/13625187.2020.1799348] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
OBJECTIVES The aims of the study were to compare the 12 month continuation rate, level of satisfaction and bleeding patterns of a once-a-month combined injectable contraceptive (CIC; Femiject), a 3 monthly progestogen-only injectable contraceptive (depot medroxyprogesterone acetate [DMPA]) and combined oral contraceptives (COCs). METHODS A prospective observational study was conducted at Aziz Medical Centre, Karachi, Pakistan. The study comprised 171 married women aged 19-35 years and requesting contraception. Participants were offered injectable contraceptives or COCs and evaluated twice: once at the beginning of the study and again after 12 months, or earlier if they discontinued use. RESULTS Sixty (35.1%) women chose COCs, 53 (31.0%) chose DMPA and 58 (33.9%) chose the CIC. The continuation rate was higher among CIC users (p = .034). CIC users were more satisfied with their method compared with those who chose COCs or DMPA (63.8% vs 25.0% and 28.3%, respectively). Most CIC users said they were likely or very likely to use the method again (63.8%); only 25.9% said they would not recommend it to a friend. CIC users had, however, more spotting compared with COC users (60.3% vs 3.3%; p ˂ .001). CONCLUSION As the continuation rate, level of satisfaction and bleeding profile of CIC users was promising, increased uptake should be encouraged. Our study shows that CIC is a good option for women requesting contraception.
Collapse
Affiliation(s)
- Rubina Izhar
- Department of Gynaecology and Obstetrics, Aziz Medical Centre, Karachi, Pakistan
| | - Samia Husain
- Department of Gynaecology and Obstetrics, Aziz Medical Centre, Karachi, Pakistan
| | - Muhammad Ahmad Tahir
- Department of Gynaecology and Obstetrics, Aziz Medical Centre, Karachi, Pakistan
| | - Sonia Husain
- Department of Gynaecology and Obstetrics, Aziz Medical Centre, Karachi, Pakistan
| |
Collapse
|
8
|
Wildemeersch D, Goldstuck N, Hasskamp T, Jandi S, Pett A. Intrauterine device quo vadis? Why intrauterine device use should be revisited particularly in nulliparous women? Open Access J Contracept 2015; 6:1-12. [PMID: 29386919 PMCID: PMC5683133 DOI: 10.2147/oajc.s72687] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
Background Long-acting reversible contraceptive (LARC) methods, including intrauterine devices (IUDs) and the contraceptive implant, are considered the best methods for preventing unintended pregnancies, rapid repeat pregnancy, and abortion in young women. An opinion paper of 2012 by the American College of Obstetricians and Gynecologists recommends Mirena and Paragard for use in nulliparous and adolescent women. However, these IUDs are not designed for young women and are not optimal as they often lead to early discontinuation. Objective This article was written with the objective to respond to the urgent need to improve intrauterine contraception as it is likely that the objectives of LARC will not be met without significant improvement of IUD design. Anatomical variations in size and shape of the uterus are not sufficiently considered, producing harm and suffering, which often lead to early removal of the IUD. Proposed problem solving The article describes why IUDs should be revisited to meet the challenge of LARC and proposes how to solve these problems. The opinion statement presented here may be considered provocative but is based on hundreds of women with IUD problems who consult or are referred to the practices of the authors of this article due to the disproportion between the IUD and their small uterine cavity. The solution is simple but requires a revision of the current design of IUDs. One-dimensional (longitudinal) IUDs are likely to be the first option. Framed devices with shortened transverse arm and IUDs which adapt to the width of the given uterus are viewed as second best. Conclusion One of the reasons of the high unintended pregnancy rate in the USA may be the paucity of suitable IUDs. Also, the legal climate in the USA seems to be a problem for developers as many lawsuits have recently been reported. Clinical studies conducted in young nulliparous and adolescent women suggest that IUDs that fit well in the uterine cavity, like a shoe, result in better tolerance, less side effects, and last but not least, higher use continuation rates.
Collapse
Affiliation(s)
- Dirk Wildemeersch
- Gynecological Outpatient Clinic and IUD Training Center, Ghent, Belgium
| | - Norman Goldstuck
- Department of Obstetrics and Gynaecology, Faculty of Medicine and Health Sciences, Stellenbosch University and Tygerberg Hospital, Western Cape, South Africa
| | | | - Sohela Jandi
- Gynecological Outpatient Clinic, Berlin, Germany
| | - Ansgar Pett
- Gynecological Outpatient Clinic, Berlin, Germany
| |
Collapse
|
9
|
Wildemeersch D, Jandi S, Pett A, Nolte K, Hasskamp T, Vrijens M. Use of frameless intrauterine devices and systems in young nulliparous and adolescent women: results of a multicenter study. Int J Womens Health 2014; 6:727-34. [PMID: 25125987 PMCID: PMC4130709 DOI: 10.2147/ijwh.s65462] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
BACKGROUND The purpose of this study was to provide additional data on the experience with frameless copper and levonorgestrel (LNG) intrauterine devices (IUDs) in nulliparous and adolescent women. METHODS Nulliparous and adolescent women, 25 years of age or younger, using the frameless copper IUD or the frameless LNG-releasing intrauterine system (IUS), were selected from previous studies and a current multicenter post-marketing study with the frameless copper IUD. The small copper-releasing GyneFix(®) 200 IUD consists of four copper cylinders, each 5 mm long and only 2.2 mm wide. The frameless FibroPlant(®) LNG-IUS consists of a fibrous delivery system releasing the hormone levonorgestrel (LNG-IUS). The main features of these intrauterine contraceptives are that they are frameless, flexible, and anchored to the fundus of the uterus. RESULTS One hundred and fifty-four nulliparous and adolescent women participated in the combined study. One pregnancy occurred with the GyneFix 200 IUD after unnoticed early expulsion of the device (cumulative pregnancy rate 1.1 at one year). Two further expulsions were reported, one with the GyneFix 200 IUD and the other with the FibroPlant LNG-IUS. The cumulative expulsion rate at one year was 1.1 with the copper IUD and 2.2 with the LNG-IUS. The total discontinuation rate at one year was low (3.3 and 4.3 with the copper IUD and LNG-IUS, respectively) and resulted in a high rate of continuation of use at one year (96.7 with the copper IUD and 95.7 with the LNG-IUS, respectively). Continuation rates for both frameless copper IUD and frameless LNG-IUS remained high at 3 years (>90%). There were no cases of perforations or pelvic inflammatory disease reported during or following insertion. CONCLUSION This report confirms earlier studies with frameless devices and suggests that the high user continuation rate is attributable to the optimal relationship between the IUD and the uterine cavity. IUD studies have shown that an IUD that does not fit well will often lead to side effects (ie, pain, bleeding, embedment, expulsion) and subsequent removal of the IUD. Early discontinuation is not the aim of long-acting reversible contraception.
Collapse
Affiliation(s)
- Dirk Wildemeersch
- Gynecological Outpatient Clinic and IUD Training Center, Ghent, Belgium
| | - Sohela Jandi
- Gynecological Outpatient Clinic, Berlin, Belgium
| | - Ansgar Pett
- Gynecological Outpatient Clinic, Berlin, Belgium
| | | | | | | |
Collapse
|