Schoutteten MK, Lindeboom L, Brys A, Lanssens D, Smeets CJP, De Cannière H, De Moor B, Peeters J, Heylen L, Van Hoof C, Groenendaal W, Kooman JP, Vandervoort PM. Comparison of whole body versus thoracic bioimpedance in relation to ultrafiltration volume and systolic blood pressure during hemodialysis. J Appl Physiol (1985) 2023; 135:1330-1338. [PMID: 37767559 DOI: 10.1152/japplphysiol.00600.2022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Revised: 09/25/2023] [Accepted: 09/25/2023] [Indexed: 09/29/2023] Open
Abstract
In contrast to whole body bioimpedance, which estimates fluid status at a single point in time, thoracic bioimpedance applied by a wearable device could enable continuous measurements. However, clinical experience with thoracic bioimpedance in patients on dialysis is limited. To test the reproducibility of whole body and thoracic bioimpedance measurements and to compare their relationship with hemodynamic changes during hemodialysis, these parameters were measured pre- and end-dialysis in 54 patients during two sessions. The resistance from both bioimpedance techniques was moderately reproducible between two dialysis sessions (intraclass correlations of pre- to end-dialysis whole body and thoracic resistance between session 1 and 2 were 0.711 [0.58-0.8] and 0.723 [0.6-0.81], respectively). There was a very high to high correlation between changes in ultrafiltration volume and changes in whole body thoracic resistance. Changes in systolic blood pressure negatively correlated to both bioimpedance techniques. Although the relationship between changes in ultrafiltration volume and changes in resistance was stronger for whole body bioimpedance, the relationship with changes in blood pressure was at least comparable for thoracic measurements. These results suggest that thoracic bioimpedance, measured by a wearable device, may serve as an interesting alternative to whole body measurements for continuous hemodynamic monitoring during hemodialysis.NEW & NOTEWORTHY We examined the role of whole body and thoracic bioimpedance in hemodynamic changes during hemodialysis. Whole body and thoracic bioimpedance signals were strongly related to ultrafiltration volume and moderately, negatively, to changes in blood pressure. This work supports the further development of a wearable device measuring thoracic bioimpedance longitudinally in patients on hemodialysis. As such, it may serve as an innovative tool for continuous hemodynamic monitoring during hemodialysis in hospital or in a home-based setting.
Collapse
Affiliation(s)
- Melanie K Schoutteten
- Faculty of Biomedical and Life Sciences, Limburg Clinical Research Center/Mobile Health Unit, Hasselt University, Diepenbeek, Belgium
- Department of Future Health, Ziekenhuis Oost Limburg, Genk, Belgium
- Department of Health Research, imec the Netherlands, Eindhoven, The Netherlands
| | - Lucas Lindeboom
- Department of Health Research, imec the Netherlands, Eindhoven, The Netherlands
| | - Astrid Brys
- Division of Geriatrics, Department of Internal Medicine, Maastricht University Medical Centre, Maastricht, The Netherlands
| | - Dorien Lanssens
- Faculty of Biomedical and Life Sciences, Limburg Clinical Research Center/Mobile Health Unit, Hasselt University, Diepenbeek, Belgium
- Department of Future Health, Ziekenhuis Oost Limburg, Genk, Belgium
| | - Christophe J P Smeets
- Department of Future Health, Ziekenhuis Oost Limburg, Genk, Belgium
- Department of Health Research, imec the Netherlands, Eindhoven, The Netherlands
| | - Hélène De Cannière
- Faculty of Biomedical and Life Sciences, Limburg Clinical Research Center/Mobile Health Unit, Hasselt University, Diepenbeek, Belgium
- Department of Future Health, Ziekenhuis Oost Limburg, Genk, Belgium
| | - Bart De Moor
- Faculty of Biomedical and Life Sciences, Limburg Clinical Research Center/Mobile Health Unit, Hasselt University, Diepenbeek, Belgium
- Department of Nephrology, Jessa Ziekenhuis, Hasselt, Belgium
| | - Jacques Peeters
- Department of Nephrology, Ziekenhuis Oost Limburg, Genk, Belgium
| | - Line Heylen
- Faculty of Biomedical and Life Sciences, Limburg Clinical Research Center/Mobile Health Unit, Hasselt University, Diepenbeek, Belgium
- Department of Nephrology, Ziekenhuis Oost Limburg, Genk, Belgium
| | - Chris Van Hoof
- Imec Belgium, Leuven, Belgium
- Department of Electrical Engineering, Elektronische Circuits en Systemen, Katholieke Universiteit Leuven-ESAT, Leuven, Belgium
| | | | - Jeroen P Kooman
- Division of Nephrology, Department of Internal Medicine, Maastricht University Medical Centre, Maastricht, The Netherlands
- NUTRIM School of Nutrition and Translational Research in Metabolism, Maastricht University, Maastricht, The Netherlands
| | - Pieter M Vandervoort
- Faculty of Biomedical and Life Sciences, Limburg Clinical Research Center/Mobile Health Unit, Hasselt University, Diepenbeek, Belgium
- Department of Future Health, Ziekenhuis Oost Limburg, Genk, Belgium
- Department of Health Research, imec the Netherlands, Eindhoven, The Netherlands
- Department of Cardiology, Ziekenhuis Oost Limburg, Genk, Belgium
| |
Collapse
|
2
|
Zhang Q, Wang N, Nie L, Lu C, Chen H, He W, Li M, Wang Y, Zhao J, Xiong J. Visit-to-visit ultrafiltration volume variability predicts all-cause mortality in patients receiving hemodialysis. Ren Fail 2023; 45:2194439. [PMID: 37009917 PMCID: PMC10071946 DOI: 10.1080/0886022x.2023.2194439] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/04/2023] Open
Abstract
PURPOSE Little is known about the effect of visit-to-visit ultrafiltration volume (UV) variability on the outcome. In this study, we investigated the association between visit-to-visit UV variability and all-cause mortality in patients receiving hemodialysis (HD). METHODS We consecutively enrolled patients who received maintenance HD in our center from March 2015 to March 2021. UV variability was defined using standard deviation (UVSD) and coefficient of variation (UVCV) (standard deviation divided by the mean). The relationship between UV variability and all-cause mortality was assessed using univariate and multivariate Cox proportional hazard regression models. Receiver operating characteristic curves were used to evaluate the predictive abilities of UVSD and UVCV for short-term and long-term survival rates. RESULTS A total of 283 HD patients were included. The mean age was 57.54 years, and 53% were males. Follow-up was done for a median of 3.38 years (IQR 1.83-4.78). During the follow-up period, 73 patients died. Cox proportional hazards models indicated that UVSD and UVCV (higher versus lower) were positively associated with all-cause mortality (p=.003 and p<.001, respectively), while in multivariable-adjusted models, only higher UVCV remained significantly associated with all-cause mortality in patients receiving HD (HR 2.55 (95% CI 1.397-4.654), p=.002). Moreover, subgroup analyses showed that the predictive performance of UVCV was more accurate among older patients, males and patients with comorbidities. CONCLUSIONS Visit-to-visit UV variability, especially UVCV, is a helpful indicator for predicting all-cause mortality in patients receiving HD, especially for older patients, males and those with comorbidities.
Collapse
Affiliation(s)
- Quanchao Zhang
- Department of Nephrology, The Key Laboratory for the Prevention and Treatment of Chronic Kidney Disease of Chongqing, Chongqing Clinical Research Center of Kidney and Urology Diseases, Xinqiao Hospital, Army Medical University (Third Military Medical University), Chongqing, PR China
| | - Ning Wang
- Department of Nephrology, The Key Laboratory for the Prevention and Treatment of Chronic Kidney Disease of Chongqing, Chongqing Clinical Research Center of Kidney and Urology Diseases, Xinqiao Hospital, Army Medical University (Third Military Medical University), Chongqing, PR China
| | - Ling Nie
- Department of Nephrology, The Key Laboratory for the Prevention and Treatment of Chronic Kidney Disease of Chongqing, Chongqing Clinical Research Center of Kidney and Urology Diseases, Xinqiao Hospital, Army Medical University (Third Military Medical University), Chongqing, PR China
| | - Caibao Lu
- Department of Nephrology, The Key Laboratory for the Prevention and Treatment of Chronic Kidney Disease of Chongqing, Chongqing Clinical Research Center of Kidney and Urology Diseases, Xinqiao Hospital, Army Medical University (Third Military Medical University), Chongqing, PR China
| | - Hongwei Chen
- Department of Nephrology, The Key Laboratory for the Prevention and Treatment of Chronic Kidney Disease of Chongqing, Chongqing Clinical Research Center of Kidney and Urology Diseases, Xinqiao Hospital, Army Medical University (Third Military Medical University), Chongqing, PR China
| | - Wenchang He
- Department of Nephrology, The Key Laboratory for the Prevention and Treatment of Chronic Kidney Disease of Chongqing, Chongqing Clinical Research Center of Kidney and Urology Diseases, Xinqiao Hospital, Army Medical University (Third Military Medical University), Chongqing, PR China
| | - Moqi Li
- Department of Nephrology, The Key Laboratory for the Prevention and Treatment of Chronic Kidney Disease of Chongqing, Chongqing Clinical Research Center of Kidney and Urology Diseases, Xinqiao Hospital, Army Medical University (Third Military Medical University), Chongqing, PR China
| | - Yiqin Wang
- Department of Nephrology, The Key Laboratory for the Prevention and Treatment of Chronic Kidney Disease of Chongqing, Chongqing Clinical Research Center of Kidney and Urology Diseases, Xinqiao Hospital, Army Medical University (Third Military Medical University), Chongqing, PR China
| | - Jinghong Zhao
- Department of Nephrology, The Key Laboratory for the Prevention and Treatment of Chronic Kidney Disease of Chongqing, Chongqing Clinical Research Center of Kidney and Urology Diseases, Xinqiao Hospital, Army Medical University (Third Military Medical University), Chongqing, PR China
| | - Jiachuan Xiong
- Department of Nephrology, The Key Laboratory for the Prevention and Treatment of Chronic Kidney Disease of Chongqing, Chongqing Clinical Research Center of Kidney and Urology Diseases, Xinqiao Hospital, Army Medical University (Third Military Medical University), Chongqing, PR China
| |
Collapse
|
3
|
Jaques DA, Davenport A. Characterization of sodium removal to ultrafiltration volume in a peritoneal dialysis outpatient cohort. Clin Kidney J 2020; 14:917-924. [PMID: 33777375 PMCID: PMC7986363 DOI: 10.1093/ckj/sfaa035] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2019] [Accepted: 02/21/2020] [Indexed: 12/25/2022] Open
Abstract
Background Failure to control volume is the second most common cause of peritoneal dialysis (PD) technique failure. Sodium is primarily removed by convection, but according to the three-pore model, water and sodium movements are not necessarily concordant. We wished to determine factors increasing sodium to water clearance in clinical practice. Methods We reviewed 24-h peritoneal dialytic sodium removal (DSR) and ultrafiltration (UF) volume in consecutive PD patients attending for routine assessment of peritoneal membrane function and adequacy testing. We used a regression model with the DSR/UF ratio as the dependent variable. A second model with DSR as the dependent variable and interaction testing for UF was used as sensitivity analysis. Results We included 718 adult PD patients. Mean values were 51.8 ± 64.6 mmol/day and 512 ± 517 mL/day for DSR and UF, respectively. In multivariable analysis, DSR/UF ratio was positively associated with transport type (fast versus slow, P < 0.001), serum sodium (P < 0.001) and diabetes (P = 0.026), and negatively associated with PD mode [automated PD versus continuous ambulatory PD (CAPD), P < 0.001] and the use of 2.27% glucose dialysate (P < 0.001). Sensitivity analysis showed positive interaction with UF for transport type (P < 0.001) and serum sodium (P = 0.032) and negative interaction for PD mode (P < 0.001) and cycles number (P < 0.001). Conclusions CAPD, fast transport and high serum sodium allow relatively more sodium to be removed compared with water. Icodextrin has no effect on sodium removal once confounders have been accounted for. Although widely used in the assessment of PD patients, UF should not be considered as a surrogate for DSR in clinical practice.
Collapse
Affiliation(s)
- David A Jaques
- Division of Nephrology, Geneva University Hospitals, Geneva, Switzerland.,UCL Department of Nephrology, Royal Free Hospital, University College London, London, UK
| | - Andrew Davenport
- UCL Department of Nephrology, Royal Free Hospital, University College London, London, UK
| |
Collapse
|