1
|
Ultrasound Modulates Calcium Activity in Cultured Neurons, Glial Cells, Endothelial Cells and Pericytes. ULTRASOUND IN MEDICINE & BIOLOGY 2024; 50:341-351. [PMID: 38087717 DOI: 10.1016/j.ultrasmedbio.2023.11.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/26/2023] [Revised: 10/27/2023] [Accepted: 11/03/2023] [Indexed: 01/23/2024]
Abstract
OBJECTIVE Ultrasound is being researched as a method to modulate the brain. Studies of the interaction of sound with neurons support the hypothesis that mechanosensitive ion channels play an important role in ultrasound neuromodulation. The response of cells other than neurons (e.g., astrocytes, pericytes and endothelial cells) have not been fully characterized, despite playing an important role in brain function. METHODS To address this gap in knowledge, we examined cultured murine primary cortical neurons, astrocytes, endothelial cells and pericytes in an in vitro widefield microscopy setup during application of a 500 ms burst of 250 kHz focused ultrasound over a pressure range known to elicit neuromodulation. We examined cell membrane health in response to a range of pulses and used optical calcium indicators in conjunction with pharmacological antagonists to selectively block different groups of thermo- and mechanosensitive ion channels known to be responsive to ultrasound. RESULTS All cell types experienced an increase in calcium fluorescence in response to ultrasound. Gadolinium (Gad), 2-aminoethoxydiphenyl borate (2-APB) and ruthenium red (RR) reduced the percentage of responding neurons and magnitude of response. The percentage of astrocytes responding was significantly lowered only by Gad, whereas both 2-APB and Gad decreased the amplitude of the fluorescence response. 2-APB decreased the percentage of responding endothelial cells, whereas only Gad reduced the magnitude of responses. Pericytes exposed to RR or Gad were less likely to respond to stimulation. RR had no detectable effect on the magnitude of the pericyte responses while 2-APB and Gad significantly decreased the fluorescence intensity, despite not affecting the percentage responding. CONCLUSION Our study highlights the role of non-neuronal cells during FUS neuromodulation. All of the investigated cell types are sensitive to mechanical ultrasound stimulation and rely on mechanosensitive ion channels to undergo ultrasound neuromodulation.
Collapse
|
2
|
Selective Infrared Neural Inhibition Can Be Reproduced by Resistive Heating. Neuromodulation 2023; 26:1757-1771. [PMID: 36707292 PMCID: PMC10366334 DOI: 10.1016/j.neurom.2022.12.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2022] [Revised: 11/22/2022] [Accepted: 12/06/2022] [Indexed: 01/26/2023]
Abstract
OBJECTIVES Small-diameter afferent axons carry various sensory signals that are critical for vital physiological conditions but sometimes contribute to pathologies. Infrared (IR) neural inhibition (INI) can induce selective heat block of small-diameter axons, which holds potential for translational applications such as pain management. Previous research suggested that IR-heating-induced acceleration of voltage-gated potassium channel kinetics is the mechanism for INI. Therefore, we hypothesized that other heating methods, such as resistive heating (RH) in a cuff, could reproduce the selective inhibition observed in INI. MATERIALS AND METHODS We conducted ex vivo nerve-heating experiments on pleural-abdominal connective nerves of Aplysia californica using both IR and RH. We fabricated a transparent silicone nerve cuff for simultaneous IR heating, RH, and temperature measurements. Temperature elevations (ΔT) on the nerve surface were recorded for both heating modalities, which were tested over a range of power levels that cover a similar ΔT range. We recorded electrically evoked compound action potentials (CAPs) and segmented them into fast and slow subcomponents on the basis of conduction velocity differences between the large and small-diameter axonal subpopulations. We calculated the normalized inhibition strength and inhibition selectivity index on the basis of the rectified area under the curve of each subpopulation. RESULTS INI and RH showed a similar selective inhibition effect on CAP subcomponents for slow-conducting axons, confirmed by the inhibition probability vs ΔT dose-response curve based on approximately 2000 CAP measurements. The inhibition selectivity indexes of the two heating modalities were similar across six nerves. RH only required half the total electrical power required by INI to achieve a similar ΔT. SIGNIFICANCE We show that selective INI can be reproduced by other heating modalities such as RH. RH, because of its high energy efficiency and simple design, can be a good candidate for future implantable neural interface designs.
Collapse
|
3
|
Infrared neural stimulation markedly enhances nerve functionality assessment during nerve monitoring. Sci Rep 2023; 13:4362. [PMID: 36928795 PMCID: PMC10020565 DOI: 10.1038/s41598-023-31384-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2022] [Accepted: 03/10/2023] [Indexed: 03/18/2023] Open
Abstract
In surgical procedures where the risk of accidental nerve damage is prevalent, surgeons commonly use electrical stimulation (ES) during intraoperative nerve monitoring (IONM) to assess a nerve's functional integrity. ES, however, is subject to off-target stimulation and stimulation artifacts disguising the true functionality of the specific target and complicating interpretation. Lacking a stimulation artifact and having a higher degree of spatial specificity, infrared neural stimulation (INS) has the potential to improve upon clinical ES for IONM. Here, we present a direct comparison between clinical ES and INS for IONM performance in an in vivo rat model. The sensitivity of INS surpasses that of ES in detecting partial forms of damage while maintaining a comparable specificity and sensitivity to more complete forms. Without loss in performance, INS is readily compatible with existing clinical nerve monitoring systems. These findings underscore the clinical potential of INS to improve IONM and surgical outcomes.
Collapse
|
4
|
Development of a platform for broadband, spectra-fitted, tissue optical phantoms. JOURNAL OF BIOMEDICAL OPTICS 2023; 28:025001. [PMID: 36814953 PMCID: PMC9940728 DOI: 10.1117/1.jbo.28.2.025001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Accepted: 01/24/2023] [Indexed: 06/18/2023]
Abstract
SIGNIFICANCE Current methods of producing optical phantoms are incapable of accurately capturing the wavelength-dependent properties of tissue critical for many optical modalities. AIM We aim to introduce a method of producing solid, inorganic phantoms whose wavelength-dependent optical properties can be matched to those of tissue over the wavelength range of 370 to 950 nm. APPROACH The concentration-dependent optical properties of 20 pigments were characterized and used to determine combinations that result in optimal fits compared to the target properties over the full spectrum. Phantoms matching the optical properties of muscle and nerve, the diffuse reflectance of pale and melanistic skin, and the chromophore concentrations of a computational skin model with varying oxygen saturation ( StO 2 ) were made with this method. RESULTS Both optical property phantoms were found to accurately mimic their respective tissues' absorption and scattering properties across the entire spectrum. The diffuse reflectance phantoms were able to closely approximate skin reflectance regardless of skin type. All three computational skin phantoms were found to have emulated chromophore concentrations close to the model, with an average percent error for the StO 2 of 4.31%. CONCLUSIONS This multipigment phantom platform represents a powerful tool for creating spectrally accurate tissue phantoms, which should increase the availability of standards for many optical techniques.
Collapse
|
5
|
Visualizing Lipid Dynamics Role in Infrared Neural Stimulation using Stimulated Raman Scattering. Biophys J 2022; 121:1525-1540. [PMID: 35276133 PMCID: PMC9072573 DOI: 10.1016/j.bpj.2022.03.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2021] [Revised: 10/14/2021] [Accepted: 03/04/2022] [Indexed: 11/02/2022] Open
Abstract
Infrared neural stimulation, or INS, uses pulsed infrared light to yield label-free neural stimulation with broad experimental and translational utility. Despite its robust demonstration, INS's mechanistic and biophysical underpinnings have been the subject of debate for more than a decade. The role of lipid membrane thermodynamics appears to play an important role in how fast IR-mediated heating nonspecifically drives action potential generation. Direct observation of lipid membrane dynamics during INS remains to be shown in a live neural model system. We used hyperspectral stimulated Raman scattering (hsSRS) microscopy to study biochemical signatures of high-speed vibrational dynamics underlying INS in a live neural cell culture model. Findings suggest that lipid bilayer structural changes are occurring during INS in vitro in NG108-15 neuroglioma cells. Lipid-specific signatures of cell SRS spectra varied with stimulation energy and radiant exposure. Spectroscopic observations agree with high-speed ratiometric fluorescence imaging of a conventional lipophilic membrane structure reporter, di-4-ANNEPS. Overall, the presented findings support the hypothesis that INS causes changes in the lipid membrane of neural cells by changing lipid membrane packing order. Furthermore, this work highlights the potential of hsSRS as a method to study biophysical and biochemical dynamics safely in live cells.
Collapse
|
6
|
Ashley James Welch (A.J.). Lasers Surg Med 2022; 54:201. [PMID: 35049046 DOI: 10.1002/lsm.23520] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2022] [Accepted: 01/07/2022] [Indexed: 11/05/2022]
|
7
|
Use of an invertebrate animal model ( Aplysia californica) to develop novel neural interfaces for neuromodulation. Front Neurosci 2022; 16:1080027. [PMID: 36620467 PMCID: PMC9813496 DOI: 10.3389/fnins.2022.1080027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2022] [Accepted: 11/29/2022] [Indexed: 12/24/2022] Open
Abstract
New tools for monitoring and manipulating neural activity have been developed with steadily improving functionality, specificity, and reliability, which are critical both for mapping neural circuits and treating neurological diseases. This review focuses on the use of an invertebrate animal, the marine mollusk Aplysia californica, in the development of novel neurotechniques. We review the basic physiological properties of Aplysia neurons and discuss the specific aspects that make it advantageous for developing novel neural interfaces: First, Aplysia nerves consist only of unmyelinated axons with various diameters, providing a particularly useful model of the unmyelinated C fibers in vertebrates that are known to carry important sensory information, including those that signal pain. Second, Aplysia's neural tissues can last for a long period in an ex vivo experimental setup. This allows comprehensive tests such as the exploration of parameter space on the same nerve to avoid variability between animals and minimize animal use. Third, nerves in large Aplysia can be many centimeters in length, making it possible to easily discriminate axons with different diameters based on their conduction velocities. Aplysia nerves are a particularly good approximation of the unmyelinated C fibers, which are hard to stimulate, record, and differentiate from other nerve fibers in vertebrate animal models using epineural electrodes. Fourth, neurons in Aplysia are large, uniquely identifiable, and electrically compact. For decades, researchers have used Aplysia for the development of many novel neurotechnologies. Examples include high-frequency alternating current (HFAC), focused ultrasound (FUS), optical neural stimulation, recording, and inhibition, microelectrode arrays, diamond electrodes, carbon fiber microelectrodes, microscopic magnetic stimulation and magnetic resonance electrical impedance tomography (MREIT). We also review a specific example that illustrates the power of Aplysia for accelerating technology development: selective infrared neural inhibition of small-diameter unmyelinated axons, which may lead to a translationally useful treatment in the future. Generally, Aplysia is suitable for testing modalities whose mechanism involves basic biophysics that is likely to be similar across species. As a tractable experimental system, Aplysia californica can help the rapid development of novel neuromodulation technologies.
Collapse
|
8
|
Multi-modal nonlinear optical and thermal imaging platform for label-free characterization of biological tissue. Sci Rep 2021; 11:8067. [PMID: 33850171 PMCID: PMC8044215 DOI: 10.1038/s41598-021-86774-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Accepted: 03/08/2021] [Indexed: 11/09/2022] Open
Abstract
The ability to characterize the combined structural, functional, and thermal properties of biophysically dynamic samples is needed to address critical questions related to tissue structure, physiological dynamics, and disease progression. Towards this, we have developed an imaging platform that enables multiple nonlinear imaging modalities to be combined with thermal imaging on a common sample. Here we demonstrate label-free multimodal imaging of live cells, excised tissues, and live rodent brain models. While potential applications of this technology are wide-ranging, we expect it to be especially useful in addressing biomedical research questions aimed at the biomolecular and biophysical properties of tissue and their physiology.
Collapse
|
9
|
Optimizing thermal block length during infrared neural inhibition to minimize temperature thresholds. J Neural Eng 2021; 18. [PMID: 33735846 DOI: 10.1088/1741-2552/abf00d] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2020] [Accepted: 03/18/2021] [Indexed: 11/11/2022]
Abstract
Objective. Infrared neural inhibition (INI) is a method of blocking the generation or propagation of neural action potentials through laser heating with wavelengths strongly absorbed by water. Recent work has identified that the distance heated along axons, the block length (BL), modulates the temperature needed for inhibition; however, this relationship has not been characterized. This study explores how BL during INI can be optimized towards minimizing its temperature threshold.Approach. To understand the relationship between BL and the temperature required for INI, excised nerves fromAplysia californicawere laser-heated over different lengths of axon during electrical stimulation of compound action potentials. INI was provided by irradiation (λ= 1470 nm) from a custom probe (n= 6 nerves), and subsequent validation was performed by providing heat block using perfused hot media over nerves (n= 5 nerves).Main Results. Two BL regimes were identified. Short BLs (thermal full width at half maximum (tFWHM) = 0.81-1.13 mm) demonstrated that increasing the tFWHM resulted in lower temperature thresholds for INI (p< 0.0125), while longer BLs (tFWHM = 1.13-3.03 mm) showed no significant change between the temperature threshold and tFWHM (p> 0.0125). Validation of this longer regime was performed using perfused hot media over different lengths of nerves. This secondary heating method similarly showed no significant change (p> 0.025) in the temperature threshold (tFWHM = 1.25-4.42 mm).Significance. This work characterized how the temperature threshold for neural heat block varies with BL and identified an optimal BL around tFWHM = 1.13 mm which minimizes both the maximum temperature applied to tissue and the volume of tissue heated during INI. Understanding how to optimally target lengths of nerve to minimize temperature during INI can help inform the design of devices for longitudinal animal studies and human implementation.
Collapse
|
10
|
Isotonic ion replacement can lower the threshold for selective infrared neural inhibition. NEUROPHOTONICS 2021; 8:015005. [PMID: 33628860 PMCID: PMC7893321 DOI: 10.1117/1.nph.8.1.015005] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/26/2020] [Accepted: 01/21/2021] [Indexed: 06/12/2023]
Abstract
Significance: Infrared (IR) inhibition can selectively block peripheral sensory nerve fibers, a potential treatment for autonomic-dysfunction-related diseases (e.g., neuropathic pain and interstitial cystitis). Lowering the IR inhibition threshold can increase its translational potentials. Aim: Infrared induces inhibition by enhancing potassium channel activation. We hypothesized that the IR dose threshold could be reduced by combining it with isotonic ion replacement. Approach: We tested the IR inhibition threshold on the pleural-abdominal connective of Aplysia californica. Using a customized chamber system, the IR inhibition was applied either in normal saline or in isotonic ion-replaced saline, which could be high glucose saline, high choline saline, or high glucose/high choline saline. Each modified saline was at a subthreshold concentration for inhibiting neural conduction. Results: We showed that isotonically replacing ions in saline with glucose and/or choline can reduce the IR threshold and temperature threshold of neural inhibition. Furthermore, the size selectivity of IR inhibition was preserved when combined with high glucose/high choline saline. Conclusions: The present work of IR inhibition combined with isotonic ion replacement will guide further development of a more effective size-selective IR inhibition modality for future research and translational applications.
Collapse
|
11
|
Identifying the Role of Block Length in Neural Heat Block to Reduce Temperatures During Infrared Neural Inhibition. Lasers Surg Med 2020; 52:259-275. [PMID: 31347188 PMCID: PMC6981060 DOI: 10.1002/lsm.23139] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/30/2019] [Indexed: 01/01/2023]
Abstract
BACKGROUND AND OBJECTIVES The objective of this study is to assess the hypothesis that the length of axon heated, defined here as block length (BL), affects the temperature required for thermal inhibition of action potential propagation applied using laser heating. The presence of such a phenomenon has implications for how this technique, called infrared neural inhibition (INI), may be applied in a clinically safe manner since it suggests that temperatures required for therapy may be reduced through the proper spatial application of light. Here, we validate the presence of this phenomenon by assessing how the peak temperatures during INI are reduced when two different BLs are applied using irradiation from either one or two adjacent optical fibers. STUDY DESIGN/MATERIALS AND METHODS Assessment of the role of BL was carried out over two phases. First, a computational proof of concept was performed in the neural conduction simulation environment, NEURON, simulating the response of action potentials to increased temperatures applied at different full-width at half-maxima (FWHM) along axons. Second, ex vivo validation of these predictions was performed by measuring the radiant exposure, peak temperature rise, and FWHM of heat distributions associated with INI from one or two adjacent optical fibers. Electrophysiological assessment of radiant exposures at inhibition threshold were carried out in ex vivo Aplysia californica (sea slug) pleural abdominal nerves ( n = 6), an invertebrate with unmyelinated axons. Measurement of the maximum temperature rise required for induced heat block was performed in a water bath using a fine wire thermocouple. Finally, magnetic resonance thermometry (MRT) was performed on a nerve immersed in saline to assess the elevated temperature distribution at these radiant exposures. RESULTS Computational modeling in NEURON provided a theoretical proof of concept that the BL is an important factor contributing to the peak temperature required during neural heat block, predicting a 11.7% reduction in temperature rise when the FWHM along an axon is increased by 42.9%. Experimental validation showed that, when using two adjacent fibers instead of one, a 38.5 ± 2.2% (mean ± standard error of the mean) reduction in radiant exposure per pulse per fiber threshold at the fiber output (P = 7.3E-6) is measured, resulting in a reduction in peak temperature rise under each fiber of 23.5 ± 2.1% ( P = 9.3E-5) and 15.0 ± 2.4% ( P = 1.4E-3) and an increase in the FWHM of heating by 37.7 ± 6.4% ( P = 1E-3), 68.4 ± 5.2% ( P = 2.4E-5), and 51.9 ± 9.9% ( P = 1.7E-3) in three MRT slices. CONCLUSIONS This study provides the first experimental evidence for a phenomenon during the heat block in which the temperature for inhibition is dependent on the BL. While more work is needed to further reduce the temperature during INI, the results highlight that spatial application of the temperature rise during INI must be considered. Optimized implementation of INI may leverage this cellular response to provide optical modulation of neural signals with lower temperatures over greater time periods, which may increase the utility of the technique for laboratory and clinical use. Lasers Surg. Med. © 2019 Wiley Periodicals, Inc.
Collapse
|
12
|
Optimization of optical parameters for improved photodynamic therapy of Staphylococcus aureus using endogenous coproporphyrin III. Photodiagnosis Photodyn Ther 2019; 29:101624. [PMID: 31866531 DOI: 10.1016/j.pdpdt.2019.101624] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2019] [Revised: 11/28/2019] [Accepted: 12/17/2019] [Indexed: 12/21/2022]
Abstract
BACKGROUND It has recently been shown that endogenous photosensitization of Gram-positive bacteria is achieved through the accumulation of the heme precursor coproporphyrin III and not protoporphyrin IX, as was previously assumed. As previous studies have operated under this assumption, the efficacy of optimal targeting of the absorption peaks of coproporphyrin III has not been explored. METHODS Staphylococcus aureus was endogenously photosensitized through the addition of either the small molecule VU0038882, aminolevulinic acid, or both. The efficacy of five different LEDs whose wavelengths target different coproporphyrin III absorption peaks were determined in vitro. Based on these in vitro measurements, the effectiveness of utilizing these LEDs to treat a skin infection was predicted using a Monte Carlo simulation to estimate the fluence rates and resulting bacterial reductions as a function of depth. RESULTS Optimal targeting of the Soret band provided a 4.7-log improvement as compared to previously utilized wavelengths. Activation of the Q-bands was found to provide similar cytotoxic effects but required significantly larger doses of light. Despite near sterilization in vitro, it was predicted that Soret band targeted light would only provide at least a 2 log-reduction up to 430 μm into the skin while Q-band targeted light could remain effective up to 1 mm in depth. Multiplexing these different wavelengths was found to provide a further 0.5-1.0 log-reduction in bacterial viability. CONCLUSIONS Accurate targeting of coproporphyrin III has shown that endogenous photodynamic therapy has the potential to be further developed into an effective treatment of skin and soft tissue infections caused by Gram-positive bacteria.
Collapse
|
13
|
Voltage-gated potassium channels are critical for infrared inhibition of action potentials: an experimental study. NEUROPHOTONICS 2019; 6:040501. [PMID: 31620544 PMCID: PMC6792434 DOI: 10.1117/1.nph.6.4.040501] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/21/2019] [Accepted: 09/20/2019] [Indexed: 05/27/2023]
Abstract
Thermal block of unmyelinated axons may serve as a modality for control, suggesting a means for providing therapies for pain. Computational modeling predicted that potassium channels are necessary for mediating thermal block of propagating compound action potentials (CAPs) with infrared (IR) light. Our study tests that hypothesis. Results suggest that potassium channel blockers disrupt the ability of IR to block propagating CAPs in Aplysia californica nerves, whereas sodium channel blockers appear to have no significant effect. These observations validate the modeling results and suggest potential applications of thermal block to many other unmyelinated axons.
Collapse
|
14
|
Focal infrared neural stimulation with high-field functional MRI: A rapid way to map mesoscale brain connectomes. SCIENCE ADVANCES 2019; 5:eaau7046. [PMID: 31032400 PMCID: PMC6482007 DOI: 10.1126/sciadv.aau7046] [Citation(s) in RCA: 40] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2018] [Accepted: 03/14/2019] [Indexed: 05/13/2023]
Abstract
We have developed a way to map brain-wide networks using focal pulsed infrared neural stimulation in ultrahigh-field magnetic resonance imaging (MRI). The patterns of connections revealed are similar to those of connections previously mapped with anatomical tract tracing methods. These include connections between cortex and subcortical locations and long-range cortico-cortical connections. Studies of local cortical connections reveal columnar-sized laminar activation, consistent with feed-forward and feedback projection signatures. This method is broadly applicable and can be applied to multiple areas of the brain in different species and across different MRI platforms. Systematic point-by-point application of this method may lead to fundamental advances in our understanding of brain connectomes.
Collapse
|
15
|
Thermal block of action potentials is primarily due to voltage-dependent potassium currents: a modeling study. J Neural Eng 2019; 16:036020. [PMID: 30909171 DOI: 10.1088/1741-2552/ab131b] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
OBJECTIVE Thermal block of action potential conduction using infrared lasers is a new modality for manipulating neural activity. It could be used for analysis of the nervous system and for therapeutic applications. We sought to understand the mechanisms of thermal block. APPROACH To analyze the mechanisms of thermal block, we studied both the original Hodgkin/Huxley model, and a version modified to more accurately match experimental data on thermal responses in the squid giant axon. MAIN RESULTS Both the original and modified models suggested that thermal block, especially at higher temperatures, is primarily due to a depolarization-activated hyperpolarization as increased temperature leads to faster activation of voltage-gated potassium ion channels. The minimum length needed to block an axon scaled with the square root of the axon's diameter. SIGNIFICANCE The results suggest that voltage-dependent potassium ion channels play a major role in thermal block, and that relatively short lengths of axon could be thermally manipulated to selectively block fine, unmyelinated axons, such as C fibers, that carry pain and other sensory information.
Collapse
|
16
|
Probing the Biophysical Mechanisms of Infrared Neural Stimulation with Nonlinear Raman Imaging. Biophys J 2019. [DOI: 10.1016/j.bpj.2018.11.1490] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
|
17
|
Selective inhibition of small-diameter axons using infrared light. Sci Rep 2017; 7:3275. [PMID: 28607402 PMCID: PMC5468240 DOI: 10.1038/s41598-017-03374-9] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2016] [Accepted: 04/27/2017] [Indexed: 12/25/2022] Open
Abstract
Novel clinical treatments to target peripheral nerves are being developed which primarily use electrical current. Recently, infrared (IR) light was shown to inhibit peripheral nerves with high spatial and temporal specificity. Here, for the first time, we demonstrate that IR can selectively and reversibly inhibit small-diameter axons at lower radiant exposures than large-diameter axons. We provide a mathematical rationale, and then demonstrate it experimentally in individual axons of identified neurons in the marine mollusk Aplysia californica, and in axons within the vagus nerve of a mammal, the musk shrew Suncus murinus. The ability to selectively, rapidly, and reversibly control small-diameter sensory fibers may have many applications, both for the analysis of physiology, and for treating diseases of the peripheral nervous system, such as chronic nausea, vomiting, pain, and hypertension. Moreover, the mathematical analysis of how IR affects the nerve could apply to other techniques for controlling peripheral nerve signaling.
Collapse
|
18
|
Abstract
Our capacity to interface with the nervous system remains overwhelmingly reliant on electrical stimulation devices, such as electrode arrays and cuff electrodes that can stimulate both central and peripheral nervous systems. However, electrical stimulation has to deal with multiple challenges, including selectivity, spatial resolution, mechanical stability, implant-induced injury and the subsequent inflammatory response. Optical stimulation techniques may avoid some of these challenges by providing more selective stimulation, higher spatial resolution and reduced invasiveness of the device, while also avoiding the electrical artefacts that complicate recordings of electrically stimulated neuronal activity. This review explores the current status of optical stimulation techniques, including optogenetic methods, photoactive molecule approaches and infrared neural stimulation, together with emerging techniques such as hybrid optical-electrical stimulation, nanoparticle enhanced stimulation and optoelectric methods. Infrared neural stimulation is particularly emphasised, due to the potential for direct activation of neural tissue by infrared light, as opposed to techniques that rely on the introduction of exogenous light responsive materials. However, infrared neural stimulation remains imperfectly understood, and techniques for accurately delivering light are still under development. While the various techniques reviewed here confirm the overall feasibility of optical stimulation, a number of challenges remain to be overcome before they can deliver their full potential.
Collapse
|
19
|
Infrared neural stimulation of human spinal nerve roots in vivo. NEUROPHOTONICS 2015; 2:015007. [PMID: 26157986 PMCID: PMC4478764 DOI: 10.1117/1.nph.2.1.015007] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2014] [Accepted: 01/12/2015] [Indexed: 05/13/2023]
Abstract
Infrared neural stimulation (INS) is a neurostimulation modality that uses pulsed infrared light to evoke artifact-free, spatially precise neural activity with a noncontact interface; however, the technique has not been demonstrated in humans. The objective of this study is to demonstrate the safety and efficacy of INS in humans in vivo. The feasibility of INS in humans was assessed in patients ([Formula: see text]) undergoing selective dorsal root rhizotomy, where hyperactive dorsal roots, identified for transection, were stimulated in vivo with INS on two to three sites per nerve with electromyogram recordings acquired throughout the stimulation. The stimulated dorsal root was removed and histology was performed to determine thermal damage thresholds of INS. Threshold activation of human dorsal rootlets occurred in 63% of nerves for radiant exposures between 0.53 and [Formula: see text]. In all cases, only one or two monitored muscle groups were activated from INS stimulation of a hyperactive spinal root identified by electrical stimulation. Thermal damage was first noted at [Formula: see text] and a [Formula: see text] safety ratio was identified. These findings demonstrate the success of INS as a fresh approach for activating human nerves in vivo and providing the necessary safety data needed to pursue clinically driven therapeutic and diagnostic applications of INS in humans.
Collapse
|
20
|
Alternating current and infrared produce an onset-free reversible nerve block. NEUROPHOTONICS 2014; 1:011010. [PMID: 26157966 PMCID: PMC4478811 DOI: 10.1117/1.nph.1.1.011010] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/27/2014] [Revised: 05/19/2014] [Accepted: 07/01/2014] [Indexed: 05/11/2023]
Abstract
Nerve block can eliminate spasms and chronic pain. Kilohertz frequency alternating current (KHFAC) produces a safe and reversible nerve block. However, KHFAC-induced nerve block is associated with an undesirable onset response. Optical inhibition using infrared (IR) laser light can produce nerve block without an onset response, but heats nerves. Combining KHFAC with IR inhibition [alternating current and infrared (ACIR)] produces a rapidly reversible nerve block without an onset response. ACIR can be used to rapidly and reversibly provide onset-free nerve block in the unmyelinated nerves of the marine mollusk Aplysia californica and may have significant advantages over either modality alone. ACIR may be of great clinical utility in the future.
Collapse
|
21
|
Transient and selective suppression of neural activity with infrared light. Sci Rep 2014; 3:2600. [PMID: 24009039 PMCID: PMC3764437 DOI: 10.1038/srep02600] [Citation(s) in RCA: 95] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2013] [Accepted: 08/19/2013] [Indexed: 11/09/2022] Open
Abstract
Analysis and control of neural circuitry requires the ability to selectively activate or inhibit neurons. Previous work showed that infrared laser light selectively excited neural activity in endogenous unmyelinated and myelinated axons. However, inhibition of neuronal firing with infrared light was only observed in limited cases, is not well understood and was not precisely controlled. Using an experimentally tractable unmyelinated preparation for detailed investigation and a myelinated preparation for validation, we report that it is possible to selectively and transiently inhibit electrically-initiated axonal activation, as well as to both block or enhance the propagation of action potentials of specific motor neurons. Thus, in addition to previously shown excitation, we demonstrate an optical method of suppressing components of the nervous system with functional spatiotemporal precision. We believe this technique is well-suited for non-invasive investigations of diverse excitable tissues and may ultimately be applied for treating neurological disorders.
Collapse
|
22
|
Infrared neural stimulation of primary visual cortex in non-human primates. Neuroimage 2013; 84:181-90. [PMID: 23994125 DOI: 10.1016/j.neuroimage.2013.08.040] [Citation(s) in RCA: 92] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2013] [Revised: 08/05/2013] [Accepted: 08/15/2013] [Indexed: 11/16/2022] Open
Abstract
Infrared neural stimulation (INS) is an alternative neurostimulation modality that uses pulsed infrared light to evoke spatially precise neural activity that does not require direct contact with neural tissue. With these advantages INS has the potential to increase our understanding of specific neural pathways and impact current diagnostic and therapeutic clinical applications. In order to develop this technique, we investigate the feasibility of INS (λ=1.875μm, fiber diameter=100-400μm) to activate and modulate neural activity in primary visual cortex (V1) of Macaque monkeys. Infrared neural stimulation was found to evoke localized neural responses as evidenced by both electrophysiology and intrinsic signal optical imaging (OIS). Single unit recordings acquired during INS indicated statistically significant increases in neuron firing rates that demonstrate INS evoked excitatory neural activity. Consistent with this, INS stimulation led to focal intensity-dependent reflectance changes recorded with OIS. We also asked whether INS is capable of stimulating functionally specific domains in visual cortex and of modulating visually evoked activity in visual cortex. We found that application of INS via 100μm or 200μm fiber optics produced enhancement of visually evoked OIS response confined to the eye column where INS was applied and relative suppression of the other eye column. Stimulating the cortex with a 400μm fiber, exceeding the ocular dominance width, led to relative suppression, consistent with involvement of inhibitory surrounds. This study is the first to demonstrate that INS can be used to either enhance or diminish visual cortical response and that this can be done in a functional domain specific manner. INS thus holds great potential for use as a safe, non-contact, focally specific brain stimulation technology in primate brains.
Collapse
|
23
|
Hybrid electro-optical stimulation of the rat sciatic nerve induces force generation in the plantarflexor muscles. J Neural Eng 2012. [PMID: 23186608 DOI: 10.1088/1741-2560/9/6/066006] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Objective. Optical methods of neural activation are becoming important tools for the study and treatment of neurological disorders. Infrared nerve stimulation (INS) is an optical technique exhibiting spatially precise activation in the native neural system. While this technique shows great promise, the risk of thermal damage may limit some applications. Combining INS with traditional electrical stimulation, a method known as hybrid electro-optical stimulation, reduces the laser power requirements and mitigates the risk of thermal damage while maintaining spatial selectivity. Here we investigate the capability of inducing force generation in the rat hind limb through hybrid stimulation of the sciatic nerve. Approach. Hybrid stimulation was achieved by combining an optically transparent nerve cuff for electrical stimulation and a diode laser coupled to an optical fiber for infrared stimulation. Force generation in the rat plantarflexor muscles was measured in response to hybrid stimulation with 1 s bursts of pulses at 15 and 20 Hz and with a burst frequency of 0.5 Hz. Main results. Forces were found to increase with successive stimulus trains, ultimately reaching a plateau by the 20th train. Hybrid evoked forces decayed at a rate similar to the rate of thermal diffusion in tissue. Preconditioning the nerve with an optical stimulus resulted in an increase in the force response to both electrical and hybrid stimulation. Histological evaluation showed no signs of thermally induced morphological changes following hybrid stimulation. Our results indicate that an increase in baseline temperature is a likely contributor to hybrid force generation. Significance. Extraneural INS of peripheral nerves at physiologically relevant repetition rates is possible using hybrid electro-optical stimulation.
Collapse
|
24
|
The effect of temperature on the autofluorescence of scattering and non-scattering tissue. Lasers Surg Med 2012; 44:712-8. [PMID: 23037939 DOI: 10.1002/lsm.22080] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/04/2012] [Indexed: 11/09/2022]
Abstract
BACKGROUND AND OBJECTIVES With the increasing use of fluorescence in medical applications, a comprehensive understanding of the effect of temperature on tissue autofluorescence is essential. The purpose of this study is to explore the effect of temperature on the fluorescence of porcine cornea and rat skin and determine the relative contributions of irreversible changes in optical properties and in fluorescence yield. STUDY DESIGN/MATERIALS AND METHODS Fluorescence, diffuse reflectance, and temperature measurements were acquired from excised porcine cornea and rat skin over a temperature range of 0-80 °C. A dual excitation system was used with a 337 nm pulsed nitrogen laser for the fluorescence and a white light source for the diffuse reflectance measurements. A thermal camera measured tissue temperature. Optical property changes were inferred from diffuse reflectance measurements. The reversibility of the change in fluorescence was examined by acquiring measurements while the tissue sample cooled from the highest induced temperature to room temperature. RESULTS The fluorescence intensity decreased with increasing tissue temperature. This fluorescence change was reversible when the tissue was heated to a temperature of 45 °C, but irreversible when heated to a temperature of 80 °C. CONCLUSION Auto-fluorescence intensity dependence on temperature appears to be a combination of temperature-induced optical property changes and reduced fluorescence quantum yield due to changes in collagen structure. Temperature-induced changes in measured fluorescence must be taken into consideration in applications where fluorescence is used to diagnose disease or guide therapy.
Collapse
|
25
|
Abstract
Hybrid electro-optical neural stimulation is a novel paradigm combining the advantages of optical and electrical stimulation techniques while reducing their respective limitations. However, in order to fulfill its promise, this technique requires reduced variability and improved reproducibility. Here we used a comparative physiological approach to aid the further development of this technique by identifying the spatial and temporal factors characteristic of hybrid stimulation that may contribute to experimental variability and/or a lack of reproducibility. Using transient pulses of infrared light delivered simultaneously with a bipolar electrical stimulus in either the marine mollusk Aplysia californica buccal nerve or the rat sciatic nerve, we determined the existence of a finite region of excitability with size altered by the strength of the optical stimulus and recruitment dictated by the polarity of the electrical stimulus. Hybrid stimulation radiant exposures yielding 50% probability of firing (RE₅₀) were shown to be negatively correlated with the underlying changes in electrical stimulation threshold over time. In Aplysia, but not in the rat sciatic nerve, increasing optical radiant exposures (J cm⁻²) beyond the RE₅₀ ultimately resulted in inhibition of evoked potentials. Accounting for the sources of variability identified in this study increased the reproducibility of stimulation from 35% to 93% in Aplysia and 23% to 76% in the rat with reduced variability.
Collapse
|
26
|
In vivo analysis of laser preconditioning in incisional wound healing of wild-type and HSP70 knockout mice with Raman spectroscopy. Lasers Surg Med 2012; 44:233-44. [PMID: 22275297 DOI: 10.1002/lsm.22002] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/23/2011] [Indexed: 02/02/2023]
Abstract
BACKGROUND AND OBJECTIVE Laser preconditioning augments incisional wound healing by reducing scar tissue and increasing maximum tensile load of the healed wound [Wilmink et al. (2009) J Invest Dermatol 129(1): 205-216]. Recent studies have optimized treatments or confirmed results using HSP70 as a biomarker. Under the hypothesis that HSP70 plays a role in reported results and to better understand the downstream effects of laser preconditioning, this study utilized a probe-based Raman spectroscopy (RS) system to achieve an in vivo, spatio-temporal biochemical profile of murine skin incisional wounds as a function of laser preconditioning and the presence of HSP70. STUDY DESIGN/MATERIALS AND METHODS A total of 19 wild-type (WT) and HSP70 knockout (HSP70-/-) C57BL/6 mice underwent normal and laser preconditioned incisional wounds. Laser thermal preconditioning was conducted via previously established protocol (λ = 1.85 µm, H(0 ) = 7.64 mJ/cm(2) per pulse, spot diameter = 5 mm, Rep. rate = 50 Hz, τ(p) = 2 milliseconds, exposure time = 10 minutes) with an Aculight Renoir diode laser, with tissue temperature confirmed by real-time infrared camera measurements. Wound-healing progression was quantified by daily collection of a spatial distribution of Raman spectra. The results of RS findings were then qualified using standard histology and polarization microscopy. RESULTS Raman spectra yielded significant differences (t-test; α = 0.05) in several known biochemical peaks between WT and HSP70 (-/-) mice on wounds and in adjacent tissue early in the wound-healing process. Analysis of peak ratios implied (i) an increase in protein configuration in and surrounding the wound in WT mice, and (ii) an increased cellular trend in WT mice that was prolonged due to laser treatment. Polarization microscopy confirmed that laser treated WT mice showed increased heterogeneity in collagen orientation. CONCLUSIONS The data herein supports the theory that HSP70 is involved in normal skin protein configuration and the cellularity of early wound healing. Laser preconditioning extends cellular trends in the presence of HSP70. Despite study limitations, RS provided a non-invasive method for quantifying temporal trends in altered wound healing, narrowing candidates and design for future studies with clinically applicable instrumentation.
Collapse
|
27
|
Abstract
BACKGROUND AND OBJECTIVES Previously, we have shown that a 43°C pretreatment can provide thermotolerance to a following, more severe, thermal stress at 45°C. Using cells that lack the Hsp70 gene, we have also shown that there is still some thermotolerance in the absence of HSP70 protein. The purpose of this study was to determine which genes play a role in thermotolerance by measuring viability and proliferation of the cells at 2 days after heating. Specifically, we wanted to understand which pathways may be responsible for protecting cells in the absence of HSP70. STUDY DESIGN/MATERIALS AND METHODS Murine embryonic fibroblast cells with and without Hsp70 (MEF(+/+) and MEF(-/-), respectively) were exposed to a mild heat shock of 43°C for 30 minutes in a constant temperature water bath. After 3 hours of recovery, RNA was harvested from three heated samples alongside three untreated controls using a MicroRNeasy kit with DNAse treatment. RNA quality was verified by an Agilent Bioanalyzer. The RNA was then converted to cDNA and hybridized to Affymetrix gene expression DNA microarrays. The genes that showed a twofold change (up or down) relative to unheated controls were filtered by t-test for significance at a threshold of P < 0.05 using Genespring software. Data were verified by qRT-PCR. Genes were then categorized based upon their ontology. RESULTS While many genes were similarly upregulated, the main difference between cell types was an increase in transcription factors and nucleic acid binding proteins. Several genes known to be involved in the heat response were upregulated more than twofold (Hsp70, Hsp40, Hsp110, Hsp25, Atf3), however, another well studied heat responsive gene Hsp90 only increased by 1.5-fold under these conditions despite its role in thermotolerance. CONCLUSIONS The data herein presents genetic pathways which are candidates for further study of pretreatment protocols in laser irradiation.
Collapse
|
28
|
Pulsed infrared light alters neural activity in rat somatosensory cortex in vivo. Neuroimage 2011; 57:155-166. [PMID: 21513806 DOI: 10.1016/j.neuroimage.2011.03.084] [Citation(s) in RCA: 84] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2010] [Revised: 03/25/2011] [Accepted: 03/29/2011] [Indexed: 11/26/2022] Open
Abstract
Pulsed infrared light has shown promise as an alternative to electrical stimulation in applications where contact free or high spatial precision stimulation is desired. Infrared neural stimulation (INS) is well characterized in the peripheral nervous system; however, to date, research has been limited in the central nervous system. In this study, pulsed infrared light (λ=1.875 μm, pulse width=250 μs, radiant exposure=0.01-0.55 J/cm(2), fiber size=400 μm, repetition rate=50-200 Hz) was used to stimulate the somatosensory cortex of anesthetized rats, and its efficacy was assessed using intrinsic optical imaging and electrophysiology techniques. INS was found to evoke an intrinsic response of similar magnitude to that evoked by tactile stimulation (0.3-0.4% change in intrinsic signal magnitude). A maximum deflection in the intrinsic signal was measured to range from 0.05% to 0.4% in response to INS, and the activated region of cortex measured approximately 2mm in diameter. The intrinsic signal magnitude increased with faster laser repetition rates and increasing radiant exposures. Single unit recordings indicated a statistically significant decrease in neuronal firing that was observed at the onset of INS stimulation (0.5s stimulus) and continued up to 1s after stimulation onset. The pattern of neuronal firing differed from that observed during tactile stimulation, potentially due to a different spatial integration field of the pulsed infrared light compared to tactile stimulation. The results demonstrate that INS can be used safely and effectively to manipulate neuronal firing.
Collapse
|
29
|
Assessment of Cellular Response to Thermal Laser Injury Through Bioluminescence Imaging of Heat Shock Protein 70¶†. Photochem Photobiol 2011. [DOI: 10.1111/j.1751-1097.2004.tb09860.x] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
30
|
Neural stimulation with optical radiation. LASER & PHOTONICS REVIEWS 2011; 5:68-80. [PMID: 23082105 PMCID: PMC3472451 DOI: 10.1002/lpor.200900044] [Citation(s) in RCA: 93] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/26/2009] [Accepted: 04/08/2010] [Indexed: 05/18/2023]
Abstract
This paper reviews the existing research on infrared neural stimulation, a means of artificially stimulating neurons that has been proposed as an alternative to electrical stimulation. Infrared neural stimulation (INS) is defined as the direct induction of an evoked potential in response to a transient targeted deposition of optical energy. The foremost advantage of using optical radiation for neural stimulation is its spatial resolution. Exogenously applied or trans-genetically synthesized fluorophores are not used to achieve stimulation. Here, current work on INS is presented for motor nerves, sensory nerves, central nervous system, and in vitro preparations. A discussion follows addressing the mechanism of INS and its potential use in neuroprostheses. A brief review of neural depolarization involving other optical methods is also presented. Topics covered include optical stimulation concurrent with electrical stimulation, optical stimulation using exogenous fluorophores, and optical stimulation by transgenic induction of light-gated ion channels.
Collapse
|
31
|
Abstract
This paper reviews the existing research on infrared neural stimulation, a means of artificially stimulating neurons that has been proposed as an alternative to electrical stimulation. Infrared neural stimulation (INS) is defined as the direct induction of an evoked potential in response to a transient targeted deposition of optical energy. The foremost advantage of using optical radiation for neural stimulation is its spatial resolution. Exogenously applied or trans-genetically synthesized fluorophores are not used to achieve stimulation. Here, current work on INS is presented for motor nerves, sensory nerves, central nervous system, and in vitro preparations. A discussion follows addressing the mechanism of INS and its potential use in neuroprostheses. A brief review of neural depolarization involving other optical methods is also presented. Topics covered include optical stimulation concurrent with electrical stimulation, optical stimulation using exogenous fluorophores, and optical stimulation by transgenic induction of light-gated ion channels.
Collapse
|
32
|
Alteration of GABAergic neurotransmission by pulsed infrared laser stimulation. J Neurosci Methods 2010; 192:110-4. [PMID: 20654645 DOI: 10.1016/j.jneumeth.2010.07.014] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2010] [Revised: 07/09/2010] [Accepted: 07/11/2010] [Indexed: 11/17/2022]
Abstract
Transient electrical impulses are conventionally used to elicit physiological responses in excitable tissues. While electrical stimulation has many advantages, it requires an electrode-tissue interface, exhibits relatively low spatial selectivity and always produces a "stimulus artifact". Recently, it has been shown that pulsed, low-energy infrared laser light can evoke nerve, muscle and sensory responses similar to those induced by traditional electrical stimulation in a contact-free, damage-free, artifact-free and spatially selective manner. However, the effect of transient infrared laser light on neurotransmission in the CNS is still largely unknown. Here, we tested the effect of infrared laser light on GABAergic neurotransmission. We recorded spontaneous inhibitory postsynaptic currents (sIPSCs) from cultured rat cortical neurons prior to and after infrared laser stimulation. Using transient infrared laser light, we either stimulated the neuronal soma that had axonal projections to the recorded neuron or directly stimulated the axons that projected to the recorded neuron. Optical stimulation led to enhanced amplitude, decreased decay time constant and increased frequency of sIPSCs. These alterations of sIPSC properties produced by optical stimulation were specifically mediated by GABA(A) receptors and caused by the transient laser light per se since no exogenous substances such as caged compounds were used. These data show that optical stimulation using transient infrared laser light can alter GABAergic neurotransmission and demonstrate that it may be an alternative approach to electrical stimulation in studying GABAergic function.
Collapse
|
33
|
Abstract
Mesenchymal stem cells (MSC) have a therapeutic potential in patients with fractures to reduce the time of healing and treat nonunions. The use of MSC to treat fractures is attractive for several reasons. First, MSCs would be implementing conventional reparative process that seems to be defective or protracted. Secondly, the effects of MSCs treatment would be needed only for relatively brief duration of reparation. However, an integrated approach to define the multiple regenerative contributions of MSC to the fracture repair process is necessary before clinical trials are initiated. In this study, using a stabilized tibia fracture mouse model, we determined the dynamic migration of transplanted MSC to the fracture site, their contributions to the repair process initiation, and their role in modulating the injury-related inflammatory responses. Using MSC expressing luciferase, we determined by bioluminescence imaging that the MSC migration at the fracture site is time- and dose-dependent and, it is exclusively CXCR4-dependent. MSC improved the fracture healing affecting the callus biomechanical properties and such improvement correlated with an increase in cartilage and bone content, and changes in callus morphology as determined by micro-computed tomography and histological studies. Transplanting CMV-Cre-R26R-Lac Z-MSC, we found that MSCs engrafted within the callus endosteal niche. Using MSCs from BMP-2-Lac Z mice genetically modified using a bacterial artificial chromosome system to be beta-gal reporters for bone morphogenic protein 2 (BMP-2) expression, we found that MSCs contributed to the callus initiation by expressing BMP-2. The knowledge of the multiple MSC regenerative abilities in fracture healing will allow design of novel MSC-based therapies to treat fractures.
Collapse
|
34
|
Combined optical and electrical stimulation of neural tissue in vivo. JOURNAL OF BIOMEDICAL OPTICS 2009; 14:060501. [PMID: 20059232 PMCID: PMC2789115 DOI: 10.1117/1.3257230] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2009] [Revised: 08/13/2009] [Accepted: 09/08/2009] [Indexed: 05/25/2023]
Abstract
Low-intensity, pulsed infrared light provides a novel nerve stimulation modality that avoids the limitations of traditional electrical methods such as necessity of contact, presence of a stimulation artifact, and relatively poor spatial precision. Infrared neural stimulation (INS) is, however, limited by a 2:1 ratio of threshold radiant exposures for damage to that for stimulation. We have shown that this ratio is increased to nearly 6:1 by combining the infrared pulse with a subthreshold electrical stimulus. Our results indicate a nonlinear relationship between the subthreshold depolarizing electrical stimulus and additional optical energy required to reach stimulation threshold. The change in optical threshold decreases linearly as the delay between the electrical and optical pulses is increased. We have shown that the high spatial precision of INS is maintained for this combined stimulation modality. Results of this study will facilitate the development of applications for infrared neural stimulation, as well as target the efforts to uncover the mechanism by which infrared light activates neural tissue.
Collapse
|
35
|
Abstract
BACKGROUND AND OBJECTIVE Thermal pretreatment has been shown to condition tissue to a more severe secondary heat stress. In this research we examined the particular contribution of heat shock protein 70 (HSP70) in thermal preconditioning. STUDY DESIGN/MATERIALS AND METHODS For optimization of preshock exposures, a bioluminescent Hsp70-luciferase reporter system in NIH3T3 cells tracked the activation of the Hsp70 gene. Cells in 96-well plates were pretreated in a 43 degrees C water bath for 30 minutes, followed 4 hours later with a severe heat shock at 45 degrees C for 50 minutes. Bioluminescence was measured at 2, 4, 6, 8, and 10 hours after preshock only (PS) and at 4 hours after preshock with heatshock (PS+HS). Viability was assessed 48 hours later with a fluorescent viability dye. Preshock induced thermotolerance was then evaluated in hsp70-containing Murine Embryo Fibroblast (+/+) cells and Hsp70-deficient MEF cells (-/-) through an Arrhenius damage model across varying temperatures (44.5-46 degrees C). RESULTS A time gap of 4 hours between preconditioning and the thermal insult was shown to be the most effective for thermotolerance with statistical confidence of P<0.05. The benefit of preshocking was largely abrogated in Hsp70-deficient cells. The Arrhenius data showed that preshocking leads to increases in the activation energies, E(a), and increases in frequency factors, A. The frequency factor increase was significantly greater in Hsp70-deficient cells. CONCLUSION The data shows that HSP70 contributes significantly to cellular thermotolerance but there are other pathways that provide residual thermotolerance in cells deficient in Hsp70.
Collapse
|
36
|
Abstract
Bioluminescence imaging (BLI) is frequently cited for its ease of quantification. This fundamental strength of BLI has led to applications in cancer research, cell transplantation, and monitoring of infectious disease in which bioluminescence intensity is correlated with other metrics. However, bioluminescence measurements can be influenced by a number of factors, among them source location, tissue optical properties, and substrate availability and pharmacokinetics. Accounting for these many factors is crucial for accurate BLI quantification. A number of methods can be employed to ensure correct interpretation of BLI results and validate BLI techniques. This chapter summarizes the use of calibrated light-emitting standards, bioluminescence tomography, and post-mortem validation of luciferase expression for validating quantitative BLI measurements.
Collapse
|
37
|
Intraoperative optical spectroscopy identifies infiltrating glioma margins with high sensitivity. Neurosurgery 2008; 61:327-35; discussion 335-6. [PMID: 18813157 DOI: 10.1227/01.neu.0000279226.68751.21] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
OBJECTIVE Adult gliomas have indistinct borders. As the ratio of neoplastic cells to normal cells becomes lower, the ability to detect these cells diminishes. We describe a device designed to augment intraoperative identification of both solid tumor and infiltrating tumor margins. METHODS A novel, intraoperative, optical spectroscopic tool, using both white light reflectance and 337-nm excitation fluorescence spectroscopy, is described. Discrimination algorithms have been developed to segregate neoplastic tissues from normal glial and neuronal elements. The spectroscopy device was used to measure 5 to 10 locations during glioma resection. Beneath the tool, a biopsy sample was obtained and the pathological results were reviewed in a blinded fashion. Samples were classified as solid tumor, infiltrating tumor, or normal gray or white matter. Comparisons were made between the optical spectra and the histopathological results of sampled areas in evaluating the sensitivity and specificity of the tool for tissue discrimination. RESULTS Spectral data were obtained from 24 patients with glioma and from 11 patients with temporal lobe epilepsy. A sensitivity of 80% and a specificity of 89% in discriminating solid tumor from normal tissues were obtained. In addition, infiltrating tumor margins were distinguished from normal tissues with a sensitivity of 94% and a specificity of 93%. CONCLUSION We have developed a handheld, optical spectroscopic device that may be used rapidly and in near real time with high sensitivity and reproducibility as an optical tissue discrimination tool in glioma surgery.
Collapse
|
38
|
In-vivo optical imaging of hsp70 expression to assess collateral tissue damage associated with infrared laser ablation of skin. JOURNAL OF BIOMEDICAL OPTICS 2008; 13:054066. [PMID: 19021444 PMCID: PMC3840494 DOI: 10.1117/1.2992594] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Laser surgical ablation is achieved by selecting laser parameters that remove confined volumes of target tissue and cause minimal collateral damage. Previous studies have measured the effects of wavelength on ablation, but neglected to measure the cellular impact of ablation on cells outside the lethal zone. In this study, we use optical imaging in addition to conventional assessment techniques to evaluate lethal and sublethal collateral damage after ablative surgery with a free-electron laser (FEL). Heat shock protein (HSP) expression is used as a sensitive quantitative marker of sublethal damage in a transgenic mouse strain, with the hsp70 promoter driving luciferase and green fluorescent protein (GFP) expression (hsp70A1-L2G). To examine the wavelength dependence in the mid-IR, laser surgery is conducted on the hsp70A1-L2G mouse using wavelengths targeting water (OH stretch mode, 2.94 microm), protein (amide-II band, 6.45 microm), and both water and protein (amide-I band, 6.10 microm). For all wavelengths tested, the magnitude of hsp70 expression is dose-dependent and maximal 5 to 12 h after surgery. Tissues treated at 6.45 microm have approximately 4x higher hsp70 expression than 6.10 microm. Histology shows that under comparable fluences, tissue injury at the 2.94-microm wavelength was 2x and 3x deeper than 6.45 and 6.10 microm, respectively. The 6.10-microm wavelength generates the least amount of epidermal hyperplasia. Taken together, this data suggests that the 6.10-microm wavelength is a superior wavelength for laser ablation of skin.
Collapse
|
39
|
Molecular imaging-assisted optimization of hsp70 expression during laser-induced thermal preconditioning for wound repair enhancement. J Invest Dermatol 2008; 129:205-16. [PMID: 18580963 DOI: 10.1038/jid.2008.175] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Patients at risk for impaired healing may benefit from prophylactic measures aimed at improving wound repair. Several photonic devices claim to enhance repair by thermal and photochemical mechanisms. We hypothesized that laser-induced thermal preconditioning would enhance surgical wound healing that was correlated with hsp70 expression. Using a pulsed diode laser (lambda=1.85 microm, tau(p)=2 ms, 50 Hz, H=7.64 mJ cm(-2)), the skin of transgenic mice that contain an hsp70 promoter-driven luciferase was preconditioned 12 hours before surgical incisions were made. Laser protocols were optimized in vitro and in vivo using temperature, blood flow, and hsp70-mediated bioluminescence measurements as benchmarks. Biomechanical properties and histological parameters of wound healing were evaluated for up to 14 days. Bioluminescent imaging studies indicated that an optimized laser protocol increased hsp70 expression by 10-fold. Under these conditions, laser-preconditioned incisions were two times stronger than control wounds. Our data suggest that this molecular imaging approach provides a quantitative method for optimization of tissue preconditioning and that mild laser-induced heat shock may be a useful therapeutic intervention prior to surgery.
Collapse
|
40
|
Abstract
BACKGROUND AND OBJECTIVE Transient optical nerve stimulation is a promising new non-contact, spatially precise, artifact-free neural excitation technique useful in research and clinical settings. This study evaluates safety of this pulsed infrared laser technique by histopathologic examination of stimulated peripheral nerves. STUDY DESIGN/MATERIALS AND METHODS Exposed rat sciatic nerves were functionally stimulated with the pulsed Holmium:YAG laser, previously validated as an effective tool for optical stimulation. Nerves were removed immediately and up to 2 weeks after stimulation and assessed histologically for thermal damage. Laser parameters studied include upper limits for radiant exposure, repetition rate, and duration of stimulation. RESULTS Radiant exposures with <1% probability of thermal tissue damage (0.66-0.70 J/cm(2)) are significantly greater than radiant exposures required for reliable stimulation (0.34-0.48 J/cm(2)). The upper limit for safe laser stimulation repetition rate occurs near 5 Hz. Maximum duration for constant low repetition rate stimulation (2 Hz) is approximately 4 minutes with adequate tissue hydration. CONCLUSION Results confirm that optical stimulation has the potential to become a powerful non-contact clinical and research tool for brief nerve stimulation with low risk of nerve thermal damage.
Collapse
|
41
|
Bioluminescence Imaging of Vascular Endothelial Growth Factor Promoter Activity in Murine Mammary Tumorigenesis. Mol Imaging 2007. [DOI: 10.2310/7290.2007.00029] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Vascular endothelial growth factor (VEGF) is a major inducer of angiogenesis. We generated a transgenic reporter mouse, VEGF-GL, in which an enhanced green fluorescent protein-luciferase fusion protein is expressed under the control of a human VEGF-A promoter. The VEGF-GL mouse exhibited intense bioluminescence throughout the body at 1 week of age. The signals rapidly declined to a relatively low level as the mice grew. The adult VEGF-GL mouse showed restricted bioluminescence to the areas undergoing wound healing. In contrast, the VEGF-GL mice, which were crossed with mouse mammary tumor virus-polyoma virus middle T antigen transgenic mammary tumor mice, exhibited prominent bioluminescence in the tumors, correlating with VEGF transcription. Tumor bioluminescence was observed in the bigenic mice as early as 8 weeks, before tumors were palpable, and the signals increased with tumor growth. In conclusion, the VEGF-GL mouse permits longitudinal and quantitative assessment of VEGF promoter activity in vivo. The model should facilitate understanding of the molecular controls and pathways that regulate VEGF transcription in vivo.
Collapse
|
42
|
Bioluminescence imaging of vascular endothelial growth factor promoter activity in murine mammary tumorigenesis. Mol Imaging 2007; 6:331-339. [PMID: 18092518] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/25/2023] Open
Abstract
Vascular endothelial growth factor (VEGF) is a major inducer of angiogenesis. We generated a transgenic reporter mouse, VEGF-GL, in which an enhanced green fluorescent protein-luciferase fusion protein is expressed under the control of a human VEGF-A promoter. The VEGF-GL mouse exhibited intense bioluminescence throughout the body at 1 week of age. The signals rapidly declined to a relatively low level as the mice grew. The adult VEGF-GL mouse showed restricted bioluminescence to the areas undergoing wound healing. In contrast, the VEGF-GL mice, which were crossed with mouse mammary tumor virus-polyoma virus middle T antigen transgenic mammary tumor mice, exhibited prominent bioluminescence in the tumors, correlating with VEGF transcription. Tumor bioluminescence was observed in the bigenic mice as early as 8 weeks, before tumors were palpable, and the signals increased with tumor growth. In conclusion, the VEGF-GL mouse permits longitudinal and quantitative assessment of VEGF promoter activity in vivo. The model should facilitate understanding of the molecular controls and pathways that regulate VEGF transcription in vivo.
Collapse
|
43
|
Optical parameter variability in laser nerve stimulation: a study of pulse duration, repetition rate, and wavelength. IEEE Trans Biomed Eng 2007; 54:1108-14. [PMID: 17554829 PMCID: PMC3471085 DOI: 10.1109/tbme.2007.892925] [Citation(s) in RCA: 115] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Pulsed lasers can evoke neural activity from motor as well as sensory neurons in vivo. Lasers allow more selective spatial resolution of stimulation than the conventional electrical stimulation. To date, few studies have examined pulsed, mid-infrared laser stimulation of nerves and very little of the available optical parameter space has been studied. In this study, a pulsed diode laser, with wavelength between 1.844-1.873 microm, was used to elicit compound action potentials (CAPs) from the auditory system of the gerbil. We found that pulse durations as short as 35 micros elicit a CAP from the cochlea. In addition, repetition rates up to 13 Hz can continually stimulate cochlear spiral ganglion cells for extended periods of time. Varying the wavelength and, therefore, the optical penetration depth, allowed different populations of neurons to be stimulated. The technology of optical stimulation could significantly improve cochlear implants, which are hampered by a lack of spatial selectivity.
Collapse
|
44
|
Abstract
A new method for in vivo neural activation using low-intensity, pulsed infrared light exhibits advantages over standard electrical means by providing contact-free, spatially selective, artifact-free stimulation. Here we investigate the biophysical mechanism underlying this phenomenon by careful examination of possible photobiological effects after absorption-driven light-tissue interaction. The rat sciatic nerve preparation was stimulated in vivo with a Holmium:yttrium aluminum garnet laser (2.12 microm), free electron laser (2.1 microm), alexandrite laser (750 nm), and prototype solid-state laser nerve stimulator (1.87 microm). We systematically determined relative contributions from a list of plausible interaction types resulting in optical stimulation, including thermal, pressure, electric field, and photochemical effects. Collectively, the results support our hypothesis that direct neural activation with pulsed laser light is induced by a thermal transient. We then present data that characterize and quantify the spatial and temporal nature of this required temperature rise, including a measured surface temperature change required for stimulation of the peripheral nerve (6 degrees C-10 degrees C). This interaction is a photothermal effect from moderate, transient tissue heating, a temporally and spatially mediated temperature gradient at the axon level (3.8 degrees C-6.4 degrees C), resulting in direct or indirect activation of transmembrane ion channels causing action potential generation.
Collapse
|
45
|
Validation of luminescent source reconstruction using single-view spectrally resolved bioluminescence images. APPLIED OPTICS 2007; 46:2540-7. [PMID: 17429468 DOI: 10.1364/ao.46.002540] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
We characterize the capabilities and limitations of the Living Image Software 3D Analysis package (Xenogen, Alameda, California) in the reconstruction of calibrated light sources. Sources shallower than the mean free path of light propagation suffered reconstruction inaccuracy. For sources deeper than the mean free path, the average error in depth and intensity reconstruction was less than 4% and 12%, respectively, for homogeneous tissue. The reconstruction of luminescent beads implanted within an optically heterogeneous mouse abdomen proved less accurate. The ability to distinguish multiple sources decreased with increasing source depth. A number of factors influence the accuracy of light source reconstruction.
Collapse
|
46
|
|
47
|
Pulsed laser versus electrical energy for peripheral nerve stimulation. J Neurosci Methods 2007; 163:326-37. [PMID: 17537515 PMCID: PMC2993156 DOI: 10.1016/j.jneumeth.2007.03.016] [Citation(s) in RCA: 96] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2006] [Revised: 02/26/2007] [Accepted: 03/23/2007] [Indexed: 11/25/2022]
Abstract
Transient optical neural stimulation has previously been shown to elicit highly controlled, artifact-free potentials within the nervous system in a non-contact fashion without resulting in damage to tissue. This paper presents the physiologic validity of elicited nerve and muscle potentials from pulsed laser induced stimulation of the peripheral nerve in a comparative study with the standard method of electrically evoked potentials. Herein, the fundamental physical properties underlying the two techniques are contrasted. Key laser parameters for efficient optical stimulation of the peripheral nerve are detailed. Strength response curves are shown to be linear for each stimulation modality, although fewer axons can be recruited with optically evoked potentials. Results compare the relative transient energy requirements for stimulation using each technique and demonstrate that optical methods result in highly selective functional nerve stimulation. Adjacent stimulation and recording of compound nerve potentials in their entirety from optical and electrical stimulation are presented, with optical responses shown to be free of any stimulation artifact. Thus, use of a pulsed laser exhibits distinct advantages when compared to standard electrical means for excitation of muscle potentials in the peripheral nerve in the research domain and possibly for clinical diagnostics in the future.
Collapse
|
48
|
Abstract
BACKGROUND AND OBJECTIVES For centuries, electric current has been used to stimulate neurons. Shortcomings of electrical stimulation include the contact between the stimulating electrode and the tissue, and the non-selective stimulation of the tissue. In contrast to electric stimulation, optical radiation can provide spatially selective neural stimulation without tissue contact. STUDY DESIGN/MATERIALS AND METHODS Acute in vivo experiments using gerbils were conducted to record optically evoked compound action potentials (CAPs) from the cochlea. RESULTS Optical radiation evokes CAPs in normal hearing animals and in deafened animals, in which cochleae lack outer and inner hair cells. Stimulation threshold was measured as 0.018+/-0.003 J/cm(2) (mean+/-SE). Laser radiation could be increased by 30-40 dB until drastic changes were seen in cochlear function. Cochlear response amplitudes to optical radiation were stable over extended stimulation times. CONCLUSIONS We have demonstrated that the auditory nerve can be stimulated by optical radiation. One potential clinical use of this technology would be for cochlear implants.
Collapse
|
49
|
Mid infrared optical parametric oscillator (OPO) as a viable alternative to tissue ablation with the free electron laser (FEL). Lasers Surg Med 2007; 39:230-6. [PMID: 17304561 DOI: 10.1002/lsm.20461] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND AND OBJECTIVES Investigations with a Mark-III free electron laser, tuned to 6.45 microm in wavelength have demonstrated minimal collateral damage and high ablation yield in ocular and neural tissues. While the use of mid-IR light produced by the free electron laser (FEL) has shown much promise for surgical applications, further advances are limited due the high costs of its use. Further investigation and widespread clinical use of six-micron radiation requires the development of an alternative laser source. In this research, we compared a Mark-III FEL and an Er:YAG pumped ZGP-OPO with respect to the effect of pulse duration on ablation efficiency and thermal damage on porcine cornea. STUDY DESIGN/MATERIALS AND METHODS A five by seven grid of craters was made about the center of each cornea. Craters were made with a 60-microm spotsize with a 500-microm spacing. Ablation craters were made using 50 pulses per crater at approximately three times the ablation threshold (for water). Histological analysis was used to determine crater depth and thermal damage. RESULTS The average zone of thermal damage at 6.1 microm was found to be 4.1 microm for the optical parametric oscillator (OPO) and 5.4 microm for the FEL. At 6.45 microm, the damaged zone was 7.2 microm for the OPO and 7.2 microm for the FEL. At 6.73 microm, the damaged zone was 6.3 microm for the OPO and 7.6 microm+/-0.3 microm for the FEL. CONCLUSIONS The OPO caused similar or significantly less thermal damage in porcine cornea when compared with the FEL while generating significantly deeper craters. We determined that the ZGP-OPO has much promise as a bench-top replacement for the FEL for soft tissue ablation.
Collapse
|
50
|
Abstract
Effective medical laser procedures are achieved by selecting laser parameters that minimize undesirable tissue damage. Traditionally, human subjects, animal models, and monolayer cell cultures have been used to study wound healing, tissue damage, and cellular effects of laser radiation. Each of these models has significant limitations, and consequently, a novel skin model is needed. To this end, a highly reproducible human skin model that enables noninvasive and longitudinal studies of gene expression was sought. In this study, we present an organotypic raft model (engineered skin) used in combination with bioluminescent imaging (BLI) techniques. The efficacy of the raft model was validated and characterized by investigating the role of heat shock protein 70 (hsp70) as a sensitive marker of thermal damage. The raft model consists of human cells incorporated into an extracellular matrix. The raft cultures were transfected with an adenovirus containing a murine hsp70 promoter driving transcription of luciferase. The model enables quantitative analysis of spatiotemporal expression of proteins using BLI. Thermal stress was induced on the raft cultures by means of a constant temperature water bath or with a carbon dioxide (CO2) laser (lambda=10.6 microm, 0.679 to 2.262 Wcm2, cw, unfocused Gaussian beam, omegaL=4.5 mm, 1 min exposure). The bioluminescence was monitored noninvasively with an IVIS 100 Bioluminescent Imaging System. BLI indicated that peak hsp70 expression occurs 4 to 12 h after exposure to thermal stress. A minimum irradiance of 0.679 Wcm2 activated the hsp70 response, and a higher irradiance of 2.262 Wcm2 was associated with a severe reduction in hsp70 response due to tissue ablation. Reverse transcription polymerase chain reaction demonstrated that hsp70 mRNA levels increased with prolonged heating exposures. Enzyme-linked immunosorbent protein assays confirmed that luciferase was an accurate surrogate for hsp70 intracellular protein levels. Hematoxylin and eosin stains verified the presence of the thermally denatured tissue regions. Immunohistochemical analyses confirmed that maximal hsp70 expression occurred at a depth of 150 microm. Bioluminescent microscopy was employed to corroborate these findings. These results indicate that quantitative BLI in engineered tissue equivalents provides a powerful model that enables sequential gene expression studies. Such a model can be used as a high throughput screening platform for laser-tissue interaction studies.
Collapse
|