1
|
First assessment of flow phenomena of acute and chronic thrombosis in the jugular veins using new ultrasound vector-flow imaging. Clin Hemorheol Microcirc 2024; 86:133-142. [PMID: 37742633 DOI: 10.3233/ch-238117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/26/2023]
Abstract
AIM First assessment of flow changes in the jugular veins using high resolution ultrasound vector flow. MATERIAL UND METHODS 15 patients (8 males, 7 females) with an age range of 35 to 82 years (mean age 58.53±12.26 years) were examined by an experienced examiner using high power ultrasound equipment (Resona R9, Mindray) with probe technology (Mindray L9-3U Linear Array transducer, 2.5 to 9.0 MHz). This group was compared with five healthy subjects (mean age 35.4±13.79 years) as a reference. To assess flow changes, the color-coded duplex sonography and the novel vector flow technique were used. The evaluation was performed of vector morphology changes, turbulence, and wall resistance measurements. RESULTS There were changes after acute and chronic thrombosis in 9 cases, and venous compression in 7 cases. Turbulence was measurable from 0.01 % to 64.44 %, the average turbulence was 19.73±22.06 %. Wall resistance measurement showed values from 0.01 Pa to 3.14 Pa, depending on the age of the thrombosis or compression. The reference veins showed turbulence of 0.94±1.5 % and a mean wall resistance of 0.05±0.05 Pa. There are statistically significant differences between normal and thrombotic or compressed veins in terms of maximum wall stress (p = 0.006) and mean degree of turbulence (p = 0.012), while the difference in mean wall stress is not statistically significant (p = 0.058). CONCLUSION Despite still existing technical limitations, the combination of V-flow and wall stress measurements in jugular vein changes suggests a high diagnostic potential.
Collapse
|
2
|
Advanced multimodal imaging of solid thyroid lesions with artificial intelligence-optimized B-mode, elastography, and contrast-enhanced ultrasonography parametric and with perfusion imaging: Initial results. Clin Hemorheol Microcirc 2023:CH239102. [PMID: 37092219 PMCID: PMC10357218 DOI: 10.3233/ch-239102] [Citation(s) in RCA: 14] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/25/2023]
Abstract
Goal of the study was the assessment of AI-assisted diagnosis of solid thyroid foci with multimodal modern ultrasound imaging. 50 patients (26-81 years, 54.7±13.1 years) were included in the study. Multimodal ultrasound imaging by means of B-mode with linear probe (4-12 MHz) with option of automated documentation of findings by means of AI, with supplementary Ultra MicroAngiography (UMA) was used. Macrovascularisation was assessed by dynamic contrast ultrasonography (CEUS) with parametric evaluation and perfusion analysis, and microvascularization was assessed by combined strain and shear wave elastography on a novel high-performance ultrasound system (Resono R9/Mindray) by an experienced examiner with independent reading. The evaluation was performed according to TI-RADS III-V.The volume of the thyroid lobes on both sides averaged 39 ml±5 ml (27 to 69 ml). The 13 cases of histologically confirmed thyroid carcinomas (8 papillary, 2 medullary, 2 microfollicular, 1 anaplastic CA) with a mean size of 15 mm±6 mm (9-21 mm) were correctly evaluated by TI-RADS V on the basis of irregular shape, induration > 2.5 m or > 30kPA and striking wash-out kinetics. Tumor lymph nodes could only be correctly detected preoperatively in one case of medullary carcinoma according to the surgical findings, based on irregular vascularization with UMA in roundish shape with cortex > 4 mm, transverse diameter up to 11 mm. In 25 cases of inhomogeneous nodular goiter an evaluation with TI-RADS III was performed in 31 cases, in 4 cases with incomplete marginal contour, partial marginal vascularization with UMA and partial wash out with indurations up to 2.5 m/s 30 kPA an evaluation with TI-RADS IV and surgical excision for nodular goiter. In 12 cases regressive nodular changes without relevant malignancy criteria resulted in nodular goiter, with focal changes up to 1.5 cm in diameter, classified as requiring control with TI-RADS III. There were no relevant changes in findings in the controls after 6 months. From the AI tool, the 20/25 goiter nodes were assessed as TI-RADS III, 7/12 adenomas, 5 goiter nodes, and 5 adenomas as TI-RADS IV, 5/13 carcinomas as TI-RADS IV, and 8/13 carcinomas as TI-RADS V.Multimodal ultrasound diagnostics supported by AI has a high diagnostic potential for the evaluation of solid thyroid lesions and standardizes the reporting with digital representative image documentation. CEUS perfusion and modern elastography techniques allow targeted follow-up of TI-RADS III findings.
Collapse
|
3
|
Current aspects of multimodal ultrasound liver diagnostics using contrast-enhanced ultrasonography (CEUS), fat evaluation, fibrosis assessment, and perfusion analysis - An update. Clin Hemorheol Microcirc 2023; 83:181-193. [PMID: 36776044 PMCID: PMC9986700 DOI: 10.3233/ch-239100] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/12/2023]
Abstract
Current ultrasound multifrequency probes allow both improved detail resolution and depth of penetration when examining the liver. Also, new developments in vascular diagnostics, elastography with fibrosis assessment, evaluation of possible steatosis, and parametric and time intensity curve (TIC) analysis of dynamic microvascularization of the liver with contrast-enhanced ultrasound sonography (CEUS) complement ultrasound-guided diagnostics. State-of-the-art high-resolution technology includes a high frame rate (HiFR) mode for CEUS, fast shear wave measurements with the sound touch quantify (STQ) mode, artifact-free flow detection using HR flow and glazing flow in combination with a special flow-adapted imaging (Ultra Micro Angiography, UMA) and additionally different assessments of possible fatty liver (UltraSound ATtenuation Imaging Technology, USAT). In 50 cases with focal liver lesions, a multimodal liver diagnosis was performed with a still new high-performance ultrasound system as part of the clarification of questions from the university liver consultation and tumor outpatient clinic.
Collapse
|
4
|
Post-mortem distribution of Iodinated Contrast Media (ICM) (iodixanol versus iopromide) in the porcine kidney after multiple bolus injections in vivo into the supra-renal aorta1. Clin Hemorheol Microcirc 2023; 85:289-295. [PMID: 36502310 DOI: 10.3233/ch-229102] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Iodinated contrast media (ICM) are widely used for diagnostic and interventional procedures in radiology and cardiology. Ideally, they should not interact with blood cells or vascular wall cells to avoid deteriorations of the blood circulation. However, it is well known that ICM can affect erythrocytes as well as endothelial cells which consequently might perturb especially the microcirculation. In former studies the influence of two ICM (iodixanol versus iopromide) on the vascular system, the development of blood stasis, on changes in renal resistive index (RRI) and vascular diameters, and on the post-mortem distribution of iodine as marker for ICM in the explanted kidneys was examined. The modus of ICM application into the supra-renal aorta followed the regime in interventional cardiology, so that 10 bolus injections were administered at steady intervals (iopromide 4,32 ml / iodixanol 5 ml) accompanied by infusion of 500 ml isotonic NaCl-solution.In the present study, the post-mortem X-ray analysis revealed that there were no differences in iodine content in the regions of the mid-cortex and the medullo-pelvic transition zone of the kidneys after application of both ICM. Remarkable differences, however, were found in the region of the capsule-near cortex, where the application of iopromide led to a significantly lower iodine content in the microcirculation. This is in good agreement with former studies, in which a maldistribution in this area, presumably due to a decrease in arteriolar inflow as a result of stasis/occlusion was shown.
Collapse
|
5
|
Multimodal ultrasound imaging with conventional B-mode, elastography, and parametric analysis of contrast-enhanced ultrasound (CEUS): A novel approach to assess small bowel manifestation in severe COVID-19 disease. Clin Hemorheol Microcirc 2022; 82:341-360. [PMID: 35871323 DOI: 10.3233/ch-221540] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
The aim was to describe the small bowel morphology with conventional B-mode and elastography and additionally to evaluate dynamic effects of COVID-19 associated small bowel microvascularization using CEUS with color coded perfusion parameters.Thirteen patients with severe COVID-19 acute respiratory distress syndrome (ARDS) were investigated. 13 patients required intensive care treatment with mechanical ventilation. Five patients required extracorporeal membrane oxygenation (ECMO). Contrast-enhanced ultrasound (CEUS) was performed by an experienced investigator as a bolus injection of up to 2.4 ml sulfur hexafluoride microbubbles via a central venous catheter. In the parametric analysis of CEUS, the flare of microbubbles over time is visualized with colors. This is the first work using parametric analysis of CEUS to detect perfusion differences in the small bowel.Parametric analysis of CEUS in the intestinal phase was carried out, using DICOM loops for 20 seconds. In 5 patients, parametric analysis revealed intraindividual differences in contrast agent behavior in the small bowel region. Analogous to the computed tomography (CT) images parametric analysis showed regions of simultaneous hyper- and hypoperfusion of the small intestine in a subgroup of patients. In 5 patients, the parametric image of transmural global contrast enhancement was visualized.Our results using CEUS to investigate small bowel affection in COVID-19 suggest that in severe COVID-19 ARDS systemic inflammation and concomitant micro embolisms may lead to disruption of the epithelial barrier of the small intestine.This is the first study using parametric analysis of CEUS to evaluate the extent of small bowel involvement in severe COVID-19 disease and to detect microemboli. In summary, we show that in COVID-19 the small bowel may also be an important interaction site. This is in line with the fact that enterocytes have been shown to a plenitude of angiotensin converting enzyme (ACE)-2 receptors as entry sites of the virus.
Collapse
|
6
|
Dynamic endoluminal contrast enhanced ultrasound (CEUS) for display of drainages in inflammatory abdominal fluid collections1. Clin Hemorheol Microcirc 2022; 80:49-59. [PMID: 35001884 DOI: 10.3233/ch-211370] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
AIM To evaluate the additive clinical value of endoluminal contrast enhanced ultrasound (CEUS) after interventional placement of drainages in abdominal fluid collections. MATERIAL/METHOD Examination of 30 patients using a 1-6 MHz convex probe (Resona 7, Mindray) to locate the fluid collection in B-Mode. Additionally, dynamic endoluminal CEUS with 1 ml sulphur-hexafluoride microbubbles was performed to measure the extent of the percutaneously drained abscesses. Independent assessment of dynamically stored images in PACS in DICOM format. Correlation to reference imaging using computed tomography (CT). RESULTS A total of 30 patients were examined (17 m, 19-78 years, mean 56.1 years). Drainages were positioned in the liver in 15 cases, in the pelvis after kidney transplantation in 4 cases, close to the spleen in 1 case and in the abdomen in 10 cases. In all cases abscesses showed marginal hyperaemia with reactive septations in CEUS. The drainage position was assessed by means of B-mode in all cases first and then by CEUS. In 4 cases CEUS showed a fistula to the pleura, in 5 cases to the peritoneum, in 2 cases to the intestine, in 5 cases to the biliary tract, corresponding to the CT. In 2 cases there was a hint of an anastomotic leakage after intestinal anastomosis, which was reliably detected by CT. The drainage was removed in 11 cases within a period of 2 to 5 days after CEUS control, in 9 cases within a period of 5 to 10 days. Another operation was necessary in 3 cases. A new drainage was placed in 2 cases. The required amount of contrast medium is 1 ml endoluminally diluted to 9 ml sodium chloride. CONCLUSION CEUS facilitates the exact localization and characterization of inflammatory abdominal fluid collections. Furthermore, possible fistulas can be detected that cannot be seen with conventional ultrasound.
Collapse
|
7
|
Surface imaging of breast implants using modern high-frequency ultrasound technology in comparison to high-end sonography with power analyses for B-scan optimization1. Clin Hemorheol Microcirc 2021; 80:487-495. [PMID: 34897080 DOI: 10.3233/ch-219204] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
AIM This study aims to evaluate optimized breast implant surface-structure analysis by comparing high-end ultrasound technology with a new high frequency technique. This comparative study used new breast implants with different surfaces in an in vitro setting. METHODS Nine idle silicon or polyurethane (PU) breast implants were examined by two investigators in an experimental in vitro study using two high-end ultrasound devices with multi-frequency transducers (6-15 MHz, 9-16 MHz, 12.5-33 MHz).The ultrasound B-Mode was optimized using tissue harmonic imaging (THI), speckle reduction imaging (SRI, level 0-5), cross beam (high, medium, low) and photopic.Using a standardized ultrasound protocol, the implants were examined in the middle (point of highest projection) and lateral, by two independent examiners.Image evaluation was performed on anonymized digital images in the PACS. The aim was to achieve an artifact-free recording of the surface structure, the surface coating, the total image structures and, as far as possible, an artifact-free internal representation of the implants.For independent surface evaluation a score was used (0 = undetectability of surface structures, rich in artifacts, 5 = best possible, artifact free image quality). RESULTS The quality of ultrasound imaging of breast implant surfaces after the optimization of B-Scan differed significantly comparing high-end ultrasound technology with modern high-frequency ultrasound technology (p < 0,05).The following setting has been found to be the best setting with the highest image quality:B-Mode, SRI value 3, Crossbeam high level with color coded imaging for B- mode. In the total examined frequency range of 6-33 MHz, the highest image quality was found in the average frequency range of 12.5-33 MHz at both measured points. For both devices, device 1 (high-end) and device 2 (high frequency) ultrasound, the image quality was in the12.5-33 MHz frequency range with an average image quality of 3.236. It was significantly higher, than in the lower frequency ranges and the same frequency range with THI. (p < 0,05). The image quality of the high-end sonography device was superior to the conventional high-frequency ultrasound device in all frequency ranges. CONCLUSION High-end ultrasound imaging technology was superior in the quality of implant surface evaluation in comparison to high-frequency ultrasound sonography. The gained knowledge can serve as a basis for further multicenter clinical application and studies with the aim to develop an objective, precise tool to evaluate the implant and the surrounding tissue with ultrasound.
Collapse
|
8
|
High resolution flow (HR Flow) and glazing flow in cases of hepatic flow changes: Comparison to color-coded Doppler sonography (CCDS). Clin Hemorheol Microcirc 2021; 79:3-17. [PMID: 34397406 PMCID: PMC8609679 DOI: 10.3233/ch-219102] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
AIM To evaluate the possibilities of flow detection using high resolution flow (HR Flow) and Glazing Flow technique in patients with liver parenchymal changes and flow changes in comparison to colour coded Doppler sonography (CCDS). MATERIAL AND METHODS All examinations were performed using a multi frequency matrix convex probe with high resolution technique (SC6-1U/Resona7, Mindray, Shenzhen, China) by one experienced examiner to evaluate the venous, portal venous and arterial liver flow with digital documentation of the dynamic flow parameters like peak systolic flow, end-diastolic flow and resistance index. For liver parenchymal stiffness changes shear wave elastography was performed with at least 10 measurements. By two independent readers an elevation was performed to evaluate the image quality and the degree of flow artefacts, from 0 = not available to 5 points with excellent image quality without flow artefacts. RESULTS All 40 patients (24 men, 16 women, age 27-83 years, mean 56±5 years) showed morphology changes from B-Mode of the liver parenchyma to inhomogeneous tissue with higher stiffness evaluated by the shear wave elastography (1.45 m/s up to 2.79 m/s±1.79 m/s, considering F1 up to F4 fibrosis) and in 15 cases histopathologically proven liver cirrhosis. In 9 cases after non-acute thrombosis flow reduction of the portal vein was the reason for the diameter less than 5 mm. Flow parameters for the venous flow were between 8 cm/s up to 29 cm/s, mean 14±4 cm/s, for the hepatic portal vein 5 cm/s up to 57 cm/s, mean 17±5 cm/s, for the hepatic artery systolic flow between 50 cm/s up to 127±33 cm/s, end-diastolic flow from 22 cm/s up to 47 cm/s±8 cm/s. Resistance index for the hepatic artery was between 0.41 up to 0.73, mean 0.67±0.25. The image quality for CCDS over all cases was evaluated for CCDS between 1 up to 4. The mean quality was 2.5±0.5, for HR Flow in combination with Glazing flow 3±0.5, with significant differences for the 2 readers (P < 0.01). CONCLUSION Combination of HR Flow with Glazing Flow could be helpful to evaluate morphological und hemodynamic changes of liver arterial flow, portal venous and venous flow. Reduction of flow artefacts in combination with a higher image quality could be helpful for optimizing the digital measurements also for follow up examinations.
Collapse
|
9
|
High-performance sonographical multimodal imaging of non cystic thyroid lesions: Chances of the preoperative diagnostics in relation to histopathology. Clin Hemorheol Microcirc 2021; 79:27-38. [PMID: 34334387 PMCID: PMC8609687 DOI: 10.3233/ch-219101] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
AIM: To improve preoperative diagnostics of solid non-cystic thyroid lesions by using new high-performance ultrasound techniques: optimized B-mode morphology, elastography, Color-Coded Doppler-Sonography (CCDS) and contrast enhanced ultrasound (CEUS) MATERIALS AND METHODS: In 33 cases solid, non-cystic thyroid lesions were rated as TIRADS 3 and up from conventional B-mode examinations. Additional high resolution Power Doppler including HR- and Glazing-Flow as optimized macrovascularization techniques, shear wave elastography and CEUS were performed on these patients by one experienced examiner. For CEUS a bolus of 1–2.4 ml Sulfurhexafluorid microbubbles (SonoVue®, Bracco, Milan, Italy) was injected into a cubital vein and then the distribution kinetics of the contrast agent were documented from the early arterial phase (10 to 15 seconds after injection) to the late venous phase (5 minutes after injection). Postoperative histopathology was the diagnostic gold standard as it provides the most reliable proof. RESULTS: 33 patients (13 males, 20 females; age 29 –77 years; mean 55 years; SD 13 years) were included in this study. 28 of them had benign regressive thyroid nodules, 3 had adenomas and 4 were diagnosed with carcinomas (3 were histologically identified as papillary thyroid carcinomas, one as a medullary thyroid carcinoma). The volume of the thyroid gland ranged from 6.6 to 401.3 cm2 (mean 72.6±92.0 cm2). The adenoma diameters ranged from 9 to 40 mm (mean 22±16 mm) and the carcinoma diameters ranged from 19 to 33 mm (mean 26±6 mm). The 3 adenomas had different echogenicities: One was completely echofree, one was hypoechoic and one isoechoic. The 4 carcinomas however were equally characterized as hypoechoic and echofree. Two of three adenomas and all of the carcinomas showed an incomplete or diffuse margin. Micro-calcifications were found in one adenoma and in every carcinoma. However, no micro-calcifications were observed in cases of benign regressive nodules. Performing shear-wave elastography the adenomas showed lower values than the carcinomas: The tissue velocity of the adenomas ranged from 2.86 m/s to 3.85 m/s (mean 3.32±0.5 m/s) and in carcinomas from 3.89 m/s to 5.66 m/s (mean 4.18±0.3 m/s). Marginal hypervascularization was detected in two adenomas after applying CCDS. One adenoma was hypovascularized. The four carcinomas showed an irregular extreme hypervascularization along their margins as well as an irregular central normo- or hypervascularization in CCDS. The additional HR-Flow helped reducing artefacts. In CEUS the dynamic capillary microvascularization of all carcinomas was very irregular with early enhancement and followed by partial or complete wash-out. In CEUS two adenomas had no wash-out and the other one showed a partial wash-out. CONCLUSION: Using modern multimodal imaging offers new possibilities for the differentiation between benign and malignant thyroid lesions. It is a very important diagnostic tool in addition to the B-Mode TIRADS classification and eases the decision between TIRADS 3, 4 and 5. However, additional multicenter studies are required for more detailed evaluations.
Collapse
|
10
|
Wireless point-of-care ultrasound: First experiences with a new generation handheld device. Clin Hemorheol Microcirc 2021; 79:463-474. [PMID: 34151848 PMCID: PMC8764604 DOI: 10.3233/ch-211197] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
AIM: To evaluate the diagnostic reliability of a new generation wireless point-of care ultrasound device for abdominal and thoracic findings. MATERIAL AND METHODS: 40 patients (16 females, 24 males 19 –80 years, on average 56.1 years) were scanned by an experienced examiner using the new wireless Vscan Air device for abdominal and thoracic findings. The probe frequencies were 2–5 MHz (convex probe) and 3–12 MHz for the linear probe. As a reference standard, all patients were also examined using high-end ultrasound (LOGIQ E9/LOGIQ E10). Results were interpreted independently by two examiners in consensus, also with regard to the image quality (0–4, from not assessable = 0, to excellent 4). RESULTS: In all 40 patients (100%) examination with conventional high-end ultrasound and the Vscan Air ultrasound device was feasible. Sensitivity, specificity, positive and negative predictive value for the diagnosis of abdominal and thoracic findings were 63.3%, 100%, 100%, and 40%, respectively. Most main diagnostic findings were detected using the mobile device compared to the high-end ultrasound. Limitations were found regarding characterization and classification of hepatic and renal tumorous lesions. Image quality revealed mostly minor diagnostic limitations for the mobile device, mean 2.9 (SD ± 0.300) and was excellent or with only minor diagnostic limitations for conventional high-end ultrasound, mean 3.25 (SD ± 0.438). CONCLUSION: Due to its easy application and its high diagnostic reliability, point-of-care ultrasound systems of the latest generation represent a valuable imaging method for the primary assessment of abdominal and thoracic findings, especially in patients on intensive care units or in emergency situations.
Collapse
|
11
|
Liver stiffness assessed by shear-wave elastography declines in parallel with immunoregulatory proteins in patients with chronic HCV infection during DAA therapy. Clin Hemorheol Microcirc 2021; 79:541-555. [PMID: 34120896 DOI: 10.3233/ch-211193] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
BACKGROUND A rapid decline of liver stiffness (LS) was detected by non-invasive methods in patients with chronic hepatitis C (HCV) infection during treatment with direct-acting antivirals (DAA). OBJECTIVE To investigate the influence of inflammation on LS. METHODS We prospectively examined LS by sonographic shear-wave elastography in 217 patients during DAA therapy from treatment initiation (BL) to 12 weeks after end of therapy (SVR12). Demographic data, laboratory findings and serum levels of cytokines were determined. RESULTS Values of LS decreased from 1.86 m/s to 1.68 m/s (p = 0.01) which was most pronounced in patients who had F4 fibrosis at BL (3.27 m/s to 2.37 m/s; p < 0.001). Initially elevated values of aminotransferases, ferritin, IgG (p < 0.001 each) and international normalized ratio (p < 0.003) declined, thrombocyte count (p = 0.007) increased. Correlations of these laboratory parameters with BL levels of LS measurement (LSM) were most apparent in patients with F1-F3 fibrosis. Tumor necrosis factor (TNF)-α (p = 0.031), interleukin (IL)-10 (p = 0.005) and interferon y inducible protein (IP)-10 (p < 0.001) decreased in parallel with LSM under DAA therapy and corelated with BL values. CONCLUSION Decrease of systemic inflammatory parameters correlated with LSM under DAA therapy. We conclude that regression of LSM is attributable to the decline of inflammation rather than reflecting fibrosis.
Collapse
|
12
|
Interstitial lung opacities in patients with severe COVID-19 pneumonia by bedside high-resolution ultrasound in association to CO2 retention. Clin Hemorheol Microcirc 2021; 77:355-365. [PMID: 33285628 DOI: 10.3233/ch-200925] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
BACKGROUND Coronavirus disease 2019 (COVID-19) can cause acute respiratory distress syndrome (ARDS). OBJECTIVE This single centre cross-section study aimed to grade the severity of pneumonia by bed-side lung ultrasound (LUS). METHODS A scoring system discriminates 5 levels of lung opacities: A-lines (0 points),≥3 B-line (1 point), coalescent B-lines (2 points), marked pleural disruptions (3 points), consolidations (4 points). LUS (convex 1-5 MHz probe) was performed at 6 defined regions for each hemithorax either in supine or prone position. A lung aeration score (LAS, maximum 4 points) was allocated for each patient by calculating the arithmetic mean of the examined lung areas. Score levels were correlated with ventilation parameters and laboratory markers. RESULTS LAS of 20 patients with ARDS reached from 2.58 to 3.83 and was highest in the lateral right lobe (Mean 3.67). Ferritin levels (Mean 1885μg/l; r = 0.467; p = 0.051) showed moderate correlation in spearman roh calculation. PaCO2 level (Mean 46.75 mmHg; r = 0.632; p = 0.005) correlated significantly with LAS, while duration of ventilation, Horovitz index, CRP, LDH and IL-6 did not. CONCUSIONS The proposed LAS describes severity of lung opacities in COVID-19 patients and correlates with CO2 retention in patients with ARDS.
Collapse
|
13
|
Contrast enhanced ultrasound (CEUS) with parametric imaging and time intensity curve analysis (TIC) for evaluation of the success of prostate arterial embolization (PAE) in cases of prostate hyperplasia. Clin Hemorheol Microcirc 2020; 76:143-153. [PMID: 32925006 DOI: 10.3233/ch-209202] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
AIM To evaluate the use of dynamic contrast enhanced ultrasound (CEUS) with parametric color-coded imaging and time intensity curve analysis (TIC) for planning and follow-up after prostate arterial embolization (PAE). MATERIAL/METHOD Before and after selective iliacal embolization by PAE with a follow up of 6 months 18 male patients (43-78 years, mean 63±3.5 years) with histopathological proven benign prostate hyperplasia were examined by one experienced examiner. A multifrequency high resolution probe (1-6 MHz) was used for transabdominal ultrasound and CEUS with bolus injections of 2.4 ml sulphur-hexafluoride microbubbles. Independent evaluation of color-coded parametric imaging before and after PAE by in PACS stored DICOM loops from arterial phase (10-15 s) up to 1min were performed. Criteria for successful treatment were reduction of early arterial enhancement by changes of time to peak (TTP) and area under the curve (AUC) by measurements in 8 regions of interest (ROI) of 5 mm in diameter at the margin and in the center and changes from hyperenhancement in parametric imaging (perfusion evaluation of arterial enhancement over 15 s) from red and yellow to blue and green by partial infarctions. Reference imaging method was the contrast high resolution 3 tesla magnetic resonance tomography (MRI) using 3D vibe sequences before and after PAE and for the follow up after 3 and 6 months. RESULTS PAE was technically and clinically successful in all 18 patients with less clinical symptoms and reduction of the gland volume. In all cases color-coded CEUS parametric imaging was able to evaluate partial infarction after embolization with changes from red and yellow to green and blue colors in the embolization areas. Relevant changes could be evaluated for TIC-analysis of CEUS with reduced arterial enhancement in the arterial phase and prolonged enhancement of up to 1 min with significant changes (p = 0.0024). The area under the curve (AUC) decreased from 676±255.04 rU (160 rU-1049 rU) before PAE to 370.43±255.19 rU (45 rU-858 rU) after PAE. Time to peak (TTP) did not change significantly (p = 0.6877); TTP before PAE was 25.82±9.04 s (12.3 s-42.5 s) and after PAE 24.43±9.10 s (12-39 s). Prostate volume decreased significantly (p = 0.0045) from 86.93±34.98 ml (30-139 ml) before PAE to 50.57±26.26 ml (19-117 ml) after PAE. There were no major complications and, in most cases (14/18) a volume reduction of the benign prostate hyperplasia occurred. CONCLUSION Performed by an experienced examiner CEUS with parametric imaging and TIC-analysis is highly useful to further establish prostatic artery embolization (PAE) as a successful minimal invasive treatment of benign prostatic hyperplasia.
Collapse
|
14
|
Contrast-enhanced ultrasound with perfusion analysis in patients with venous malformations before and after percutaneous treatment with ethanol-gel. Clin Hemorheol Microcirc 2020; 76:161-170. [PMID: 32925019 DOI: 10.3233/ch-209215] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
INTRODUCTION Percutaneous sclerotherapy is a well-established treatment option for venous malformations (VM). A recently established sclerosing agent is ethanol-gel. Aim of this study was to identify, if contrast-enhanced ultrasound (CEUS) with an integrated perfusion analysis allows for differentiation between untreated VM, healthy tissue, and with gelified ethanol treated malformation tissue. MATERIAL AND METHODS In this institutional review board approved prospective study symptomatic VM patients underwent CEUS at exactly the same position before and after sclerotherapy with ethanol-gel. Two experienced sonographers performed all examinations after the bolus injection of microbubbles using a multi-frequency probe with 6 -9 MHz of a high-end ultrasound machine. An integrated perfusion analysis was applied in the center of the VM and in healthy, surrounding tissue. For both regions peak enhancement (peak), time to peak (TTP), area under the curve (AUC), and mean transit time (MTT) were evaluated. Wilcoxon signed rank test was executed; p-values <0.05 were regarded statistically significant. RESULTS In 23 patients including children (mean age 25.3 years, 19 females) before treatment all identified parameters were significantly higher in the VM center compared to healthy tissue (peak: p < 0.01; TTP: p < 0.01; AUC: p < 0.01; MTT: p < 0.01). Comparing the VM center before and after treatment, TTP (p < 0.02) and MTT (p < 0.01) reduced significantly after sclerotherapy. In surrounding tissue only peak changed after treatment in comparison to pre-treatment results (p = 0.04). Comparing data in the VM center with surrounding tissue after sclerotherapy, results still differed significantly for peak (p < 0.01), TTP (p < 0.01), and AUC (p < 0.01), but assimilated for MTT (p = 0.07). CONCLUSION All with CEUS identified parameters seem to be excellent tools for differentiating between VM and healthy tissue. TTP and MTT could distinguish between with ethanol-gel sclerotized VM portions and untreated malformation parts and thereby might assist the monitoring of sclerotherapy with ethanol-gel.
Collapse
|
15
|
Imaging of breast implant and implant-associated complications: Capsular contracture and intra- or extracapsular rupture. Clin Hemorheol Microcirc 2020; 76:221-231. [PMID: 32925022 DOI: 10.3233/ch-209218] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
BACKGROUND In recent years, follow-up after breast reconstruction with silicone implants and the detection of complications have been relieved by the possibility of improved diagnostic methods. METHODS Between January 2015 and December 2019 a total of 40 patients (29-84 years) with silicone implants were included in this retrospective study. The implants were examined clinically and with modern imaging: general ultrasound imaging (US), magnetic resonance imaging (MRI), high resolution computed tomography (CT) and positron emission tomography -computed tomography (PET-CT). If necessary, a histological/cytological sample was taken. The breast implants were assessed by three radiologists specialized in breast imaging. The grade of capsular contracture was classified according to the Baker classification. RESULTS All 40 women obtained a clinical examination and an US diagnostic to identify early and more common complications such as implant folding and capsular fibrosis. Depending on the clinical examination and ultrasound findings additional MRI (n = 10), CT (n = 9) and/or PET-CT (n = 2) were performed. 16 patients had implants folding proven with US (n = 16), MRI (n = 6) and CT (n = 1). The grade of capsular fibrosis was determined according to the Baker classification. The following results were obtained in our study: 25 breast implants with Baker grade I and eleven breast implants with Baker grade II, both proven with US; one breast implants with Baker grade III and one breast implant with Baker grade IV, proven with US (n = 2), MRI (n = 1) and CT (n = 1). One patient had intracapsular rupture and one patient had extracapsular rupture, both detected on CT and surgically proven. No patient had a silicone accumulation in the lymph nodes. One patient had pathologically enlarged axillary lymph nodes, which were evaluated as inflammatory changes in PET-CT. Long-term complications such as the development of malignant breast tumors could not be observed. CONCLUSION To detect early complications after breast implant surgery, a regular clinical examination is indispensable. Imaging methods complement each other and if they are used multimodal, it is easier to identify early complications. Modern diagnostic modalities like ultrasound and magnetic resonance imaging expand the spectrum and improve diagnostic safety.
Collapse
|
16
|
Contrast enhanced ultrasound (CEUS) to assess pleural pulmonal changes in severe COVID-19 infection: First results. Clin Hemorheol Microcirc 2020; 75:19-26. [PMID: 32538830 PMCID: PMC7458509 DOI: 10.3233/ch-209005] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
AIM: Use of contrast enhanced ultrasound (CEUS) in severe cases of COVID-19 infection to assess pulmonary changes near the pleura. MATERIAL AND METHODS: Bedside examinations by an experienced intensive care unit examiner using a multi-frequency probe (C1-6 MHz) with B-mode and CEUS to assess pleural-near changes in severe cases of COVID-19 infection with respiratory failure. CEUS with bolus delivery via a central venous catheter of 2.4 ml Sulphur hexafluoride microbubbles from the arterial phase (10–15 s) to the late phase of 5 min. Digital storage of cine sequences of the lung sound with abdomen for independent assessment with the subsequently performed contrast-enhanced dual-source CT. RESULTS: In 11 intubated and ventilated patients (arithmetic mean 62 years, 48 to 78 years, 3 women) with confirmed severe COVID-19 infections, a peripherally accentuated consolidation with irregular hyperemia was found in the CEUS and also in the CT examination. Of the 5 cases with pulmonary arterial embolisms, signs of right ventricular failure were found. In all cases, using CEUS low perfused areas of the pleura with adjacent hyperemia could be detected, while, with CT segmental contrast medium, gaps with subpleural compressions were found. Interstitial changes near the pleura led to B-lines and to ground glass opacities in the CT. Near the diaphragm a delayed arterial contrast of the liver was observed. In addition, in 2 cases partial atelectasis, in 3 cases marginal pleural effusions were found. CONCLUSION: CEUS opens up new possibilities for bedside monitoring of pleural reactive inflammatory or peripheral thrombus embolism in severe cases of COVID-19 infection.
Collapse
|
17
|
Contrast enhanced ultrasonography (CEUS) to detect abdominal microcirculatory disorders in severe cases of COVID-19 infection: First experience. Clin Hemorheol Microcirc 2020; 74:353-361. [PMID: 32333581 PMCID: PMC7369109 DOI: 10.3233/ch-209003] [Citation(s) in RCA: 50] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
In the hands of experienced examiners, the contrast enhanced sonography (CEUS) offers the possibility to analyze dynamic microcirculatory disturbances in real time dynamically without any risk for kidneys and thyroid gland even in severe progressing disease bedside. Based on severe COVID-19 infections, first experiences with abdominal CEUS examinations are presented. In the stage of an imminent organ failure with significantly reduced kidney and liver function, CEUS can be used to show a narrowing of the organ-supplying arteries, as well as a delayed capillary filling of vessels near the capsule, a regional reduced parenchymal perfusion or an inflammatory hyperemia with capillary hypercirculation. It is possible to quickly rule out organ infarction and to dynamically record the mesenteric arterial and venous blood flow.
Collapse
|
18
|
Imaging of coronary arteries using ionic versus non-ionic radiographic contrast media: Intraindividual comparison study. Clin Hemorheol Microcirc 2019; 73:35-42. [PMID: 31561345 DOI: 10.3233/ch-199217] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
19
|
Influence of limited examination conditions on contrast-enhanced sonography for characterising liver lesions. Clin Hemorheol Microcirc 2019; 71:267-276. [DOI: 10.3233/ch-189417] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
20
|
Evaluation of integrated color-coded perfusion analysis for contrast-enhanced ultrasound (CEUS) after percutaneous interventions for malignant liver lesions: First results. Clin Hemorheol Microcirc 2018; 69:59-67. [PMID: 29758936 DOI: 10.3233/ch-189131] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
BACKGROUND With the rising number of percutaneous ablation therapies in malignant liver lesions there is a need of reliable diagnostics after the intervention to differentiate between reactive changes and tumor. PURPOSE To assess the success of percutaneous ablation therapies for malignant liver lesions using CEUS with perfusion analysis. MATERIAL AND METHODS Retrospective analysis of perfusion analysis for 67 patients with 94 malignant liver lesions, treated with ablation therapies. The lesions were 70 hepatocellular carcinomas (HCC), 18 metastases, 4 cholangiocellular carcinomas (CCC), 2 lesions remained unclear. CEUS was performed after bolus injection of 1.6-2.4 ml of sulfur-hexafluoride microbubbles. The perfusion analysis was calculated using Peak, TTP, mTT and AUC with integrated software during the late arterial to early portal-venous phase for approximately 9 sec (5-15 sec). For the evaluation of the success after percutaneous treatment the perfusion results were compared to the follow-up control after 6 months with CT and MRI and CEUS. RESULTS Perfusion analyses after percutaneous treatment of malignant liver lesions showed highly significant perfusion differences when comparing the center to the surrounding tissue and the margins (p<0.0001) for Peak and also for AUC. 62 lesions were successfully treated, meaning there was no local recurrence after 6 months. In cases of residual tumor CEUS showed a nodular marginal enhancement, the corresponding perfusion analyses showed nodular red and yellow pseudo-color shades. CONCLUSIONS Using CEUS and perfusion analysis, a critical analysis of post-ablation defects in malignant liver lesions is possible. With the help of pseudo-colors, remaining tumor-vascularization can be detected.
Collapse
|
21
|
Evaluation of dynamic effects of therapy-induced changes in microcirculation after percutaneous treatment of vascular malformations using contrast-enhanced ultrasound (CEUS) and time intensity curve (TIC) analyses. Clin Hemorheol Microcirc 2018; 69:45-57. [PMID: 29630543 DOI: 10.3233/ch-189118] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The aim of this follow-up study was to demonstrate the effect of percutaneous interventional treatment on local microcirculation of peripheral vascular malformations using CEUS and TIC analysis. MATERIAL AND METHODS Retrospective analysis of 197 patients (136 female; 61 male; 3-86 years) with 135 venous (VM), 39 arterio-venous (AVM), 8 lymphatic and 15 veno-lymphatic peripheral vascular malformations before and after the first percutaneous treatment.CEUS was performed after i.v. injection of 1-2.4 ml of sulfur hexafluoride microbubbles (SonoVue®) using a 6-9 MHz linear probe. Digitally stored cine loops (starting in the early arterial phase for 60 sec) were read by independent readers in consensus. Regions of interest (ROI) were defined in the center and at the margins of the malformation, as well as in the healthy surrounding tissue. TIC analyses with Time to Peak (TTP) and Area under the Curve (AUC) were calculated using integrated perfusion software. RESULTS After the treatment there was a significant decrease for median AUC in VM in the center from 297.8 (14.5-2167.6) rU down to 243.3 (0.1-1678.8) rU (p = 0.043) and in the surrounding tissue down to 107.7 (20.2-660.2) rU (p = 0.018). For the other malformations AUC decreased in the center and the margins as well. TTP rose, however these changes did not reach the level of significance. CONCLUSION Analyzing the capillary microcirculation TICs offer a possibility of monitoring therapy-induced capillary changes of vascular malformations.
Collapse
|
22
|
Reduced microperfusion due to portal vein thrombosis: Impact on the outcome of percutaneous thermal tumor ablation. Clin Hemorheol Microcirc 2018; 67:383-388. [PMID: 28885205 DOI: 10.3233/ch-179218] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
PURPOSE To determine the influence of pre-interventionally existing portal vein thrombosis on the ablation success of percutaneous tumor ablation of HCC. MATERIALS AND METHODS 15 patients with HCC and pre-existing portal vein thrombosis underwent thermal tumor ablation. We retrospectively analyzed the pre- and post-interventionally performed CT and MRI scans in terms of technical success as well as the complication rate. The portal vein thrombosis was classified into segmental, lobar and central thrombus. RESULTS In 13/15 cases (87%) complete ablation with no evidence of residual tumor tissue was seen 6 weeks after the procedure in contrast-enhanced MRI scans and contrast-enhanced ultrasound (CEUS). No major and 2 minor complications were observed after the ablation procedure. CONCLUSION Reduced perfusion due to pre-interventionally existing portal vein thrombosis has no significant impact on the ablation success or the complication rate.
Collapse
|
23
|
Effect of iodinated contrast media on renal perfusion: A randomized comparison study in pigs using quantitative contrast-enhanced ultrasound (CEUS). Sci Rep 2017; 7:13125. [PMID: 29030579 PMCID: PMC5640687 DOI: 10.1038/s41598-017-13253-y] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2017] [Accepted: 09/08/2017] [Indexed: 12/17/2022] Open
Abstract
The administration of iodinated contrast media (CM) can cause microcirculatory disorder leading to acute renal dysfunction. In a prospective, randomized investigation two CM (Iodixanol vs Iopromide) were compared in 16 pigs. Each animal received 10 intra-aortal injections (5 ml Iodixanol or 4.32 ml Iopromide). Microcirculation was assessed using contrast-enhanced ultrasound (CEUS) directly on the kidney surface using time-to-peak (TTP) and blood-volume-analysis. Macroscopic observations were documented. Post mortem residual CM distribution in the kidneys was detected using X-ray. TTP was significantly prolonged over the descending vasa recta of the Iopromide group. This coincided with a visible marble-like pattern on the kidney surface occurring in 30 out of 80 Iopromide-injections but in 4 out of 80 Iodixanol-injections (p = 0.007). The blood volume over the entire kidney did not change after Iodixanol-application, but decreased by about 6.1% after Iopromide-application. The regional blood volume in the renal cortex showed a tendency to decrease by about 13.5% (p = 0.094) after Iodixanol-application, and clearly decreased by about 31.7% (p = 0.022) after Iopromide-application. The study revealed a consistent influence of repeated injections of two different CM on the kidney perfusion using three different imaging methods (CEUS analysis, macroscopic observation and X-ray analysis).
Collapse
|
24
|
Contrast-enhanced ultrasound to evaluate organ microvascularization after operative versus endovascular treatment of visceral artery aneurysms. Clin Hemorheol Microcirc 2017; 64:689-698. [PMID: 27802212 DOI: 10.3233/ch-168003] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
PURPOSE To evaluate the organ microvascularization after operative versus endovascular treatment of visceral artery aneurysms (VAAs) by contrast-enhanced ultrasound (CEUS) and colour-coded duplex sonography (CCDS). METHOD AND MATERIALS Between April 1995 to January 2016, 168 patients (78 males, 90 females; median age: 62 years) were diagnosed with VAAs at our hospital site. 60/168 patients (36%) fulfilled treatment criteria and had either open (29/60, 48%) or endovascular (31/60, 52%) aneurysm repair. Patients' characteristics and presentations were consecutively reviewed. Technical success and organ microvascularization were determined by CCDS/CEUS and correlated to computed tomography angiography (CTA) or magnetic resonance imaging (MRI). RESULTS 18/60 patients (30%) presented with acute bleeding. 16/18 emergency patients (89%) were treated by endovascular means. After emergency treatment, two patients showed segmental liver malperfusion by CEUS and CTA. One small bowel resection had to be performed.42/60 patients (70%) were electively treated. 27/42 patients (64%) had open and 15/42 (36%) endovascular aneurysm repair. There were no liver or bowel infarctions after elective treatment of hepatic or mesenteric artery aneurysms (n = 13) in CCDS/CEUS and in CTA. Treatment of patients with splenic or renal artery aneurysms led to partial or complete organ loss in 42% (8/19) after operative and in 50% (5/10) after endovascular treatment (p < 0.05). CONCLUSION The endovascular approach is the preferred therapeutic option in emergency to control bleeding. In contrast to hepatic or mesenteric procedures, patients for elective splenic or renal artery aneurysm repair have to be evaluated very carefully because of a high rate of partial or complete organ loss demonstrated by CEUS - either after open or endovascular aneurysm repair.
Collapse
|
25
|
Analysis of arterial dynamic micro-vascularization with contrast-enhanced ultrasound (CEUS) in thyroid lesions using external perfusion software: First results. Clin Hemorheol Microcirc 2017; 64:747-755. [PMID: 27792004 DOI: 10.3233/ch-168044] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
AIM To determine different perfusion characteristics of histo-pathologically proven adenomas and carcinomas of the thyroid gland with CEUS and perfusion software. MATERIAL AND METHODS Retrospective perfusion analysis of 25 patients with carcinomas and 41 cases of adenomas of the thyroid gland (30 males, 36 females; aged 18 - 85 years, mean 56 years). All cases were histologically analyzed. Perfusion analysis was independently performed using external perfusion software (VueBox®). TTP, mTT, Peak and Rise time were calculated. RESULTS Lesions' sizes ranged from 0.2 to 10.2 cm in carcinomas (mean 2.18 cm), and from 0.6 to 5.0 cm in adenomas (mean 2.25 cm). In 20 out of 25 carcinomas that were evaluated with CEUS, a complete wash-out in the late venous phase was found. Adenomas showed wash-out at the border.Perfusion analysis in VueBox® revealed some parameters which tend to show differences between adenomas and carcinomas, however did not reach the level of significance.Median Peak in carcinomas was highest at the margins (2945 rU), and lowest in the surroundings (1110 rU). Mean Transit Time (mTT) values showed no differences between center, margin and surrounding.In adenomas healthy tissue showed higher mTT values compared to the center (24.6 vs. 20.7 sec). Median Peak was highest in the surrounding tissue and lowest in the margins (1999 vs. 1129 rU). No statistical differences could be found in the comparisons. CONCLUSION CEUS with perfusion analysis offers new possibilities for the dynamic evaluation of micro-vascularization in thyroid adenomas and carcinomas. Using VueBox® the perfusion analysis of the arterial phase provides new parameters that help determine a lesion's malignancy or benignity. However a final assessment regarding malignancy and benignity of thyroid lesions using only CEUS and perfusion analysis of the arterial phase is not yet possible.
Collapse
|
26
|
Intrasurgical dignity assessment of hepatic tumors using semi-quantitative strain elastography and contrast-enhanced ultrasound for optimisation of liver tumor surgery. Clin Hemorheol Microcirc 2017; 64:735-745. [PMID: 27767982 DOI: 10.3233/ch-168029] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
OBJECTIVE To evaluate the efficacy of strain elastography (SE) using semi-quantitative measurement methods compared to constrast enhanced ultrasound during liver tumor surgery (Io-CEUS) for dignity assessment of focal liver lesions(FLL). MATERIAL AND METHODS Prospective data acquisition and retrospective analysis of US data of 100 patients (116 lesions) who underwent liver tumor surgery between 10/2010 and 03/2016. Retrospective reading of SE color patterns was performed establishing groups depending on dominant color (>50% blue = stiff, inhomogenous, >50% yellow/red/green = soft tissue). Semi-quantitative analysis was performed by Q-analysis based on a scale from 0 (soft) to 6 (stiff). 2 ROIs were placed centrally, 5 ROIs in the lesion's surrounding tissue. Io-CEUS was performed by bolus injection of 5-10 ml sulphurhexaflourid microbubbles evaluating wash-in- and -out- kinetics in arterial, portal venous and late phase. Histopathology after surgical resection served as goldstandard. RESULTS 100 patients (m: 65, f: 35, mean age 60.5 years) with 116 liver lesions were included. Lesion's size ranged from 0.5 to 8.4 cm (mean 2.42 cm SD±1.44 cm). Postoperative histology showed 105 malignant and 11 benign lesions. Semi-quantitative analysis showed central indurations of >2.5 in 76/105 cases suggesting malignancy. 7 benign lesions displayed no central indurations correctly characterized benign by SE. ROC-analysis and Youden index showed a sensitivity of 72.4% and specificity of 63.6% assuming a cut-off of 2.5. Io-CEUS correctly characterized 103/105 as malignant. Sensitivity was 98%, specificity 72.7%. CONCLUSION Strain elastography is a valuable tool for non-invasive characterization of FLLs. Semi-quantitative intratumoral stiffness values of >2.5 suggested malignancy. However, sensitivity of Io-CEUS in detecting malignant lesions was higher compared to SE. In conclusion SE should be considered for routine use during intraoperative US in addition to Io-CEUS for optimization of curative liver surgery.
Collapse
|
27
|
Effect of radiographic contrast media on renal perfusion - First results. Clin Hemorheol Microcirc 2017; 64:287-295. [PMID: 28128758 DOI: 10.3233/ch-168110] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Intra-arterial administration of radiographic contrast media (CM) is discussed to impair renal perfusion. The pathogenesis of contrast-induced Nephropathy (CIN) is still not clarified. OBJECTIVE This trial was performed to prove the effects of two CM with different molecular structure on renal perfusion. METHODS A prospective, randomized study on 16 pigs was designed to compare the outcome after application of a low-osmolar iodinated CM (770 mOsm/kg H2O - Group1) and an iso-osmolar iodinated CM (290 mOsm/kg H2o - Group2).Color Coded Doppler Sonography (LOGIQ E9, GE, Milwaukee, USA) was applied for measuring the Renal Resistive Index (RRI) before and after the first, fifth, and tenth bolus of CM. Statistics was performed using analysis of variance for repeated measurements with the Factor "CM". RESULTS All flow spectra were documented free of artifacts and Peak Systolic Velocity (PSV), Enddiastolic Velocity (EDV) and RRI respectively could be calculated. Mean PSV in Group 1 led to a decrease while in Group 2 PSV showed a significant increase after CM (p = 0,042). The course of the mean EDV in both groups deferred accordingly (p = 0,033). Mean RRI over time significantly deferred in both groups (p = 0,001). It showed a biphasic course in Group 2 and a decrease over time in Group 2. CONCLUSION While iso-osmolar CM induced an increase of PSV and EDV together with a decrease of RRI, low-osmolar CM could not show this effect or rather led to the opposite.
Collapse
|
28
|
Abstract
CLINICAL/METHODICAL ISSUE For diagnostic and interventional procedures ultrasound (US) image fusion can be used as a complementary imaging technique. METHODICAL INNOVATIONS Image fusion has the advantage of real time imaging and can be combined with other cross-sectional imaging techniques. PERFORMANCE With the introduction of US contrast agents sonography and image fusion have gained more importance in the detection and characterization of liver lesions. ACHIEVEMENTS Fusion of US images with computed tomography (CT) or magnetic resonance imaging (MRI) facilitates the diagnostics and postinterventional therapy control. PRACTICAL RECOMMENDATIONS In addition to the primary application of image fusion in the diagnosis and treatment of liver lesions, there are more useful indications for contrast-enhanced US (CEUS) in routine clinical diagnostic procedures, such as intraoperative US (IOUS), vascular imaging and diagnostics of other organs, such as the kidneys and prostate gland.
Collapse
|
29
|
Diffusion-weighted imaging in oral squamous cell carcinoma using 3 Tesla MRI: is there a chance for preoperative discrimination between benign and malignant lymph nodes in daily clinical routine? Acta Radiol 2016; 57:939-46. [PMID: 26454065 DOI: 10.1177/0284185115609365] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2015] [Accepted: 09/01/2015] [Indexed: 11/15/2022]
Abstract
BACKGROUND Preoperative staging of cervical lymph nodes is important to determine the extent of neck dissection in patients with oral squamous cell carcinoma (OSCC). PURPOSE To evaluate whether a preoperative discrimination of benign and malignant cervical lymph nodes with diffusion-weighted imaging (DWI) (3T) is feasible for clinical application. MATERIAL AND METHODS Forty-five patients with histological proven OSCC underwent preoperative 3T-MRI. DWI (b = 0, 500, and 1000 s/mm(2)) was added to the standard magnetic resonance imaging (MRI) protocol. Mean apparent diffusion coefficients (ADCmean) were measured for lymph nodes with 3 mm or more in short axis by two independent readers. Finally, these results were matched with histology. RESULTS Mean ADC was significantly higher for malignant than for benign nodes (1.143 ± 0.188 * 10(-3) mm(2)/s vs. 0.987 ± 0.215 * 10(-3) mm(2)/s). Using an ADC value of 0.994 * 10(-3) mm(2)/s as threshold results in a sensitivity of 80%, specificity of 65%, positive predictive value of 31%, and negative predictive value of 93%. CONCLUSION Due to a limited sensitivity and specificity DWI alone is not suitable to reliably discriminate benign from malignant cervical lymph nodes in daily clinical routine. Hence, the preoperative determination of the extent of neck dissection on the basis of ADC measurements is not meaningful.
Collapse
|
30
|
Evaluation of the diagnostic accuracy of CEUS in children with benign and malignant liver lesions and portal vein anomalies. Clin Hemorheol Microcirc 2016; 61:333-45. [PMID: 26444615 DOI: 10.3233/ch-152003] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
OBJECTIVE Comparison of the diagnostic findings of MRI, CT and CEUS in children with benign and malignant and portal venous anomalies of the liver. MATERIALS/METHODS Retrospective analysis of the diagnostic findings of CEUS, MRI and CT scans in 56 children (age 0-17 years) with a total of 60 benign and malignant liver lesions and anomalies of the portal vein/perfusion. All patients underwent CEUS using sulphur hexafluoride microbubbles and a multi-frequency probe (1-5 MHz, 6-9 MHz). Cine-loops were stored up to 3 minutes. MRI was performed in 38 lesions. CT was performed in 8 lesions. RESULTS Out of the 56 patients 49 liver lesions (48 benign, 1 malignant), 9 anomalies of the portal vein/perfusion and 2 of the biliary system were detected. 16/49 lesions were analyzed histopathologically. Using CEUS, the characterization of the lesions was possible in 45 out of 49 cases. In 32 cases, CEUS provided the exact diagnosis. Only two benign lesions were falsely categorized as malignant.Findings of MRI and CEUS were concordant in 84% of cases (n = 32/38). CEUS considered 1 benign lesion to be malignant. 2 lesions were not detectable and in 3 lesions no definite diagnosis was established using MRI.Findings of CT and CEUS were concordant in 5 of 8 cases. In 21 lesions CEUS as the only imaging modality was found to be sufficient for diagnostics. CONCLUSION Despite the restricted indications for using CEUS in children, it offers a high diagnostic detection rate (93%) for characterization of liver lesions and portal vein anomalies.
Collapse
|
31
|
Percutaneous irreversible electroporation (IRE) of prostate cancer: Contrast-enhanced ultrasound (CEUS) findings. Clin Hemorheol Microcirc 2016; 61:135-41. [PMID: 26410867 DOI: 10.3233/ch-151985] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
PURPOSE To evaluate the use of contrast-enhanced ultrasound (CEUS) after irreversible electroporation (IRE) of prostatic cancer tissue to assess the ablation status by depicting microvascularisation in the ablation area. MATERIALS AND METHODS Retrospective evaluation of CEUS of 13 patients (mean age: 61.4 ± 7.5 years) with histologically confirmed prostatic cancer who underwent percutaneous IRE. In the course of clinical routine, the tumor lesions were documented before, immediately after, and 1 day after the ablationusing color-coded transabdominal and transrectal CEUS. The obtained image data (DICOM loops and images) were subsequently evaluated by 2 experienced radiologists and assessed with regard to micro vascularisation by means of a 5-point scale. RESULTS CEUS images showed significantly reduced microcirculation of the lesions (mean 0.9 ± 0.6 cm (0.5-1.5 cm) after IRE. Microcirculation was reduced from 2.15 ± 0.56 prior to ablation to 0.65 ± 0.63 (p < 0.001) immediately after the ablation and to 0.27 ± 0.44 one day after IRE (p < 0.001). CONCLUSION This study showed rapid and significant reduction of the microcirculation in the ablation area afterpercutaneous IRE of prostatic cancer tissue.
Collapse
|
32
|
High-Resolution Ultrasound Including Contrast-Enhanced Ultrasound (CEUS) for the Detection of Gas Formation during Aspergillus Fumigatus Infection in Mice. ULTRASCHALL IN DER MEDIZIN (STUTTGART, GERMANY : 1980) 2016; 37:277-282. [PMID: 25741669 DOI: 10.1055/s-0034-1398873] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
PURPOSE A. fumigatus infections represent a major threat for patients with a suppressed immune system. Early diagnosis is of importance for a favorable outcome but appears to be difficult due to limited diagnostic procedures. Here we investigated the sensitivity of high-resolution ultrasound (HRU) for the detection of A. fumigatus infection in the liver. MATERIALS AND METHODS BALB/c mice were intravenously infected with A. fumigatus and monitored by HRU, Doppler sonography (CCDS), contrast-enhanced ultrasound (CEUS), and real-time strain color-coded elastography (CCE) using a multi-frequency probe (6 - 15 MHz). Contrast media bolus injection of sulfur-hexafluoride micro-bubbles was applied and digital cine-loops from the arterial phase, as well as the portal venous phase up to the late phase of the whole liver were analyzed. All data were correlated to the histopathological findings. RESULTS Using HRU and CEUS, a sonic shadow was detected in all infected animals. All Aspergillus-infected nodes from 3 - 6 mm in the liver showed a shadow with rim enhancement and no intranodal enhancement when using CEUS. A. fumigatus infection was confirmed by CFU assessment and histopathological analysis. Granulomas were not associated with shadowing on B-mode. In contrast, granulomas with a diameter above 5 mm and a higher stiffness in CCE generated particularly an arterial rim enhancement and portal venous washout without contrast media uptake in the late phase. In addition, CEUS was able to define dynamic capillary microvascularization of infected liver areas. CONCLUSION Liver lesions associated with A. fumigatus infection can be detected in mice when combined with CEUS and CCE in vivo.
Collapse
|
33
|
Improved Detection of preclinical Colorectal Liver Metastases by High Resolution Ultrasound including Molecular Ultrasound Imaging using the targeted Contrast Agent BR55. ULTRASCHALL IN DER MEDIZIN (STUTTGART, GERMANY : 1980) 2016; 37:290-296. [PMID: 27112624 DOI: 10.1055/s-0041-111838] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
PURPOSE Aim of the present study was to investigate the sensitivity of high resolution ultrasound (HRU), standard contrast-enhanced ultrasound (CEUS) and CEUS using a novel vascular endothelial growth factor receptor 2 (VEGFR2)-targeted contrast agent for the detection of hepatic metastases in a mouse model of colorectal cancer using clinical standard technology. MATERIALS AND METHODS The human colon cancer cell line HT29, transfected with luciferase cDNA for in vivo bioluminescence monitoring, was injected intrasplenically into CB17.SCID mice. Mice were monitored weekly by bioluminescence and after 2 and 4.5 weeks by HRU and CEUS. Contrast media (untargeted BR1, targeted BR55) was applied and digital cine loops from the arterial phase (15 - 45 sec), portal venous phase (50 - 120 s) and late phases (3 - 5 min, 1hour) of the whole liver were analyzed. Data were correlated with postmortem histopathology. RESULTS Without contrast enhancement, lesions > 4 mm were reliably detected. After use of untargeted CEUS, lesions > 2 mm were reliably detected and enhanced rim vascularization and late-phase wash-out was shown. With BR55, lesions > 0.8 mm were reliably detected with excellent documentation of vascularization. A persistent contrast enhancement was seen > 30 min after injection. Contrast-enhancement patterns with BR55 significantly correlated with CD31 (R2 = 0.74) and VEGFR2-immunohistochemistry (R2 = 0.66). CONCLUSION Detection of metastases by HRU and CEUS was earlier and more accurate than monitoring via bioluminescence. In vivo monitoring of hepatic micrometastases can thus be performed without prior modification of cancer cells using standard technology.
Collapse
|
34
|
Trauma-Schall. ROFO-FORTSCHR RONTG 2016. [DOI: 10.1055/s-0036-1581762] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
35
|
Percutaneous Ablation of Hepatic Tumors Using Irreversible Electroporation: A Prospective Safety and Midterm Efficacy Study in 34 Patients. J Vasc Interv Radiol 2016; 27:480-6. [PMID: 26922979 DOI: 10.1016/j.jvir.2015.12.025] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2015] [Revised: 12/08/2015] [Accepted: 12/20/2015] [Indexed: 12/18/2022] Open
Abstract
PURPOSE To evaluate the safety and efficacy of percutaneous irreversible electroporation (IRE) of primary and secondary liver cancer unsuitable for resection or thermal ablation. MATERIALS AND METHODS In this prospective, single-center study, 65 malignant liver tumors (hepatocellular carcinoma, n = 33; cholangiocellular carcinoma, n = 5; colorectal cancer metastasis, n = 22; neuroendocrine cancer metastasis, n = 3; testicular cancer metastasis, n = 2) in 34 patients (27 men, 7 women; mean age, 59.4 y ± 11.2) were treated. Local recurrence-free survival (LRFS) according to the Kaplan-Meier method was evaluated after a median follow-up of 13.9 months. RESULTS Median tumor diameter was 2.4 cm ± 1.4 (range, 0.2-7.1 cm). Of 65 tumors, 12 (18.5%) required retreatment because of incomplete ablation (n = 3) or early local recurrence (n = 9). LRFS at 3, 6, and 12 months was 87.4%, 79.8%, and 74.8%. The median time to progressive disease according to modified Response Evaluation Criteria In Solid Tumors was 15.6 months. Overall complication rate was 27.5% with six major complications and eight minor complications. Major complications included diffuse intraperitonal bleeding (n = 1), partial thrombosis of the portal vein (n = 1), and liver abscesses (n = 4). Minor complications were liver hematomas (n = 6) and clinically inapparent pneumothoraces (n = 2). CONCLUSIONS IRE showed promising results regarding therapeutic efficacy for the percutaneous treatment of liver tumors; however, significant concerns remain regarding its safety.
Collapse
|
36
|
Modern Ultrasound Diagnostic Procedures in an Interdisciplinary Ultrasound Department: Challenge and Opportunities for Radiologists. ROFO-FORTSCHR RONTG 2015; 188:27-32. [PMID: 26695846 DOI: 10.1055/s-0041-103463] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
Interdisciplinary ultrasound departments are sources for modern and effective ultrasound diagnostic procedures. Radiologists have a very important role as part of these centers for the establishment of new diagnostic ultrasound modalities like contrast-enhanced ultrasound (CEUS), image fusion between US and computed tomography (CT) and magnetic resonance tomography (MRI), resulting in new interventional procedures. Data acquisition and the development of solutions for PACS are also important points.
Collapse
|
37
|
Evaluating post-interventional occlusion grades of cerebral aneurysms with transcranial contrast-enhanced ultrasound (CEUS) using a matrix probe. ULTRASCHALL IN DER MEDIZIN (STUTTGART, GERMANY : 1980) 2015; 36:168-173. [PMID: 25607631 DOI: 10.1055/s-0034-1398835] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
PURPOSE The main goal of cerebral endovascular aneurysm therapy is the complete occlusion of the aneurysm. Along with the development of new aneurysm treatment devices, repeated controls are necessary. We examined whether contrast-enhanced ultrasound can help to monitor aneurysms after endovascular treatment. MATERIALS AND METHODS We prospectively examined 12 patients after coiling (7 patients) or flow diverter (FD) implantation (5 patients). These patients were examined with transcranial contrast-enhanced ultrasound using a matrix probe (1 - 5 MHz). Doppler sonography, Power Doppler, contrast harmonic imaging (CHI) and Power Doppler sonography (CPD) were included in the examination. Digital subtraction angiography with 3 D reconstructions served as the gold standard. Two radiologists decided in consensus about the degree of aneurysm occlusion separately in CEUS and digital subtraction angiography using a 4-point grading scheme. RESULTS The degree of occlusion of the 12 aneurysms comparing the two imaging modalities was identical in 10 cases. In two cases CHI and CPD showed a small aneurysm remnant after coiling in the center of the coil pack while in digital subtraction angiography the aneurysms seemed completely occluded. CONCLUSION The investigation indicates that contrast-enhanced ultrasound is a supportive, noninvasive method for post-interventional controls of intracranial aneurysms due to its ability to display not only macro- but also microvascularization.
Collapse
|
38
|
Evaluating Post-Interventional Occlusion Grades of Cerebral Aneurysms with Transcranial Contrast-Enhanced Ultrasound (CEUS) Using a Matrix Probe. ULTRASCHALL IN DER MEDIZIN (STUTTGART, GERMANY : 1980) 2015; 36:E1. [PMID: 25629594 DOI: 10.1055/s-0034-1398958] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
|
39
|
Factors associated with short-term local recurrence of liver cancer after percutaneous ablation using irreversible electroporation: a prospective single-center study. J Vasc Interv Radiol 2015; 26:694-702. [PMID: 25812712 DOI: 10.1016/j.jvir.2015.02.001] [Citation(s) in RCA: 48] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2014] [Revised: 01/26/2015] [Accepted: 02/01/2015] [Indexed: 02/08/2023] Open
Abstract
PURPOSE To evaluate the risk factors associated with short-term local recurrence of malignant liver lesions after irreversible electroporation (IRE). MATERIALS AND METHODS Thirty-nine consecutive patients (79 malignant liver lesions) were treated with IRE, of whom 14 were excluded from the analysis (including 12 without 6 mo of follow-up and two with incomplete ablation). The remaining 25 patients (aged 59.4 y ± 11.2) had 48 malignant liver lesions, including 22 hepatocellular carcinomas (HCCs), six cholangiocellular carcinomas, and 20 metastatic liver cancers. Multivariate analyses were used to evaluate the associations of risk factors with early recurrence. The characteristics of patients, lesions, and IRE procedures were assessed by logistic regression. RESULTS Fourteen of the 48 treated lesions (29.2%) showed early local recurrence after 6 months. Tumor volume (< 5 cm(3) vs ≥ 5 cm(3); P = .022) and underlying disease type (HCC, cholangiocellular carcinoma, or metastatic disease; P = .023) were independently associated with early local recurrence. However, distances to the surrounding portal veins (< 0.5 cm vs ≥ 0.5 cm; P = .810), hepatic veins (P = .170), hepatic arteries (P = .761), and bile ducts (P = .226) were not significantly associated with local recurrence. CONCLUSIONS Because short distances to the surrounding vessels were not associated with early local recurrence, percutaneous IRE might provide an alternative treatment option for perivascular tumors. However, patients with larger tumor volumes appeared to be poor candidates for percutaneous IRE. Regarding the different types of treated lesions, patients with HCC had significantly better outcomes.
Collapse
|
40
|
Contrast-enhanced ultrasound (CEUS) detects effects of vascular disrupting therapy in an experimental model of gastric cancer. Clin Hemorheol Microcirc 2015; 56:287-99. [PMID: 23271198 DOI: 10.3233/ch-121658] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
OBJECTIVE To assess the effects of vascular-disrupting agent (VDA)-based therapy including monitoring of therapeutic efficacy with contrast-enhanced ultrasound (CEUS) in a gastric cancer model. MATERIALS & METHODS Gastric cancer cell lines and endothelial cells were used. Effects of the VDA ASA404 on cells were determined by MTT assays and Western blotting in vitro. Therapeutic efficacy of ASA404 was assessed in vivo in a subcutaneous mouse model in combination with paclitaxel. CEUS with TIC (time intensity curve) analyses was employed to measure tumor perfusion. Finally, tumor tissue was harvested and processed for histological work-up. RESULTS In vitro, ASA404 impaired growth of ECs upon stimulation with conditioned media from gastric cancer cells. No direct effects on tumor cells were observed. In vivo treatment with ASA404 in combination with paclitaxel led to significant decrease of tumor microvascularization as determined by CEUS. Furthermore, combination of ASA404 with paclitaxel showed a significant inhibition of tumor growth which was paralleled by strong reduction of tumor cell proliferation and vessel area. CONCLUSION VDA-based therapy in combination with paclitaxel, and therapy monitoring by CEUS, appears to be a promising strategy for gastric cancer.
Collapse
|
41
|
New economic training model for installing ultrasound-guided drainages. ZEITSCHRIFT FUR GASTROENTEROLOGIE 2014; 52:1257-62. [PMID: 25390212 DOI: 10.1055/s-0034-1385134] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
Abscesses and circumscribed collections of fluid are frequently found as complications of infectious diseases or surgery. Drainage is often indicated. We have established a new, economic, easy-to-make model to learn and improve competence in installing ultrasound-guided drainage. Up to fifteen water balloons (size 30 - 50 mm) were placed in a plastic box which then was filled with instant custard powder mixed with water. Spiral computed tomography (CT) of this box was performed. Experienced (n = 8) and inexperienced examiners (n = 8) drained the balloons via a direct puncture technique using either ultrasound-guidance alone or volume navigation with image fusion (ultrasound and CT) with needle tracking. Trainees filled out a questionnaire (before and after training) asking for information on their experience in ultrasound, in installing drainages and evaluating the new model. The time needed for installing the drainage was measured. None of the participants had ever attended a course on drainage installation. Only a few of the experienced examiners (n = 3) would autonomously install a drainage into a fluid collection with a size exceeding 4 cm before training. After training all participants felt more confident in ultrasound and in installing drainages into abscesses or other fluid collections. Most of the participants rated additional volume navigation with image fusion as a helpful tool. Ultrasound-guided drainage of abscesses can be trained easily with this new and economic model. Students and physicians can improve their skills and gain confidence in performing ultrasound-guided interventions.
Collapse
|
42
|
Abstract
CLINICAL/METHODICAL ISSUE Optimization of ultrasound guided interventional procedures of the liver and kidneys using new imaging methods. STANDARD RADIOLOGICAL METHODS Punctures, biopsies, drainage, intraoperative ultrasound, fusion, embolization in correlation with ultrasound and other imaging methods. METHODICAL INNOVATIONS Real-time-sonography, contrast-enhanced ultrasound (CEUS) and fusion for planning, monitoring and postinterventional control. PERFORMANCE The use of CEUS enables better detection, characterization and execution of interventional procedures. Fusion facilitates detection. ACHIEVEMENTS The CEUS procedure is superior for detection and characterization of smaller lesions in comparison to the B scan. Fusion enables the performance of difficult interventional procedures. PRACTICAL RECOMMENDATIONS The B scan is the standard imaging method but CEUS and fusion could be helpful for smaller lesions.
Collapse
|
43
|
Bildfusion und Volumennavigation US/CEUS mti CT/MRT/PET. ROFO-FORTSCHR RONTG 2014. [DOI: 10.1055/s-0034-1373434] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
44
|
Kontinuierliche dynamische Registrierung von Mikrovaskularisation bei Lebertumoren mittels Kontrastmittelultraschall (CEUS). ROFO-FORTSCHR RONTG 2014. [DOI: 10.1055/s-0034-1372787] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
45
|
Die Bedeutung des CEUS in der Untersuchung der Schilddrüse und Nebenschilddrüse. ROFO-FORTSCHR RONTG 2014. [DOI: 10.1055/s-0034-1373439] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
46
|
Neue Ultraschalltechniken für Punktionen, Biopsien, Drainagen. ROFO-FORTSCHR RONTG 2014. [DOI: 10.1055/s-0034-1373435] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
47
|
Bildfusion mit CT/MRT-Datensätzen. ROFO-FORTSCHR RONTG 2014. [DOI: 10.1055/s-0034-1373442] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
48
|
Moderne Ultraschalltechniken bei RFA und TACE. ROFO-FORTSCHR RONTG 2014. [DOI: 10.1055/s-0034-1373436] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
49
|
[Ultrasonic AG -- contrast-enhanced (CEUS) in radiology: A preliminary analysis and critical evaluation of AGUS]. ROFO-FORTSCHR RONTG 2014; 186:417-9. [PMID: 24691808 DOI: 10.1055/s-0034-1368938] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
50
|
Postoperative monitoring of local and free flaps with contrast-enhanced ultrasound (CEUS)--analysis of 112 patients. ULTRASCHALL IN DER MEDIZIN (STUTTGART, GERMANY : 1980) 2013; 34:550-558. [PMID: 24127394 DOI: 10.1055/s-0033-1355758] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
PURPOSE Tissue defects are a common problem in trauma surgery and oncology. Flap transplantation is often the only therapy to cover such defects. Several monitoring systems are currently available but none has made it to the clinical routine. The aim of this study was to assess perfusion disturbances of local and free flaps using contrast-enhanced ultrasound (CEUS). MATERIALS AND METHODS 112 patients were examined during the first 72 hours after operation. CEUS was performed by one experienced examiner with a linear transducer (6 - 9 MHz, LOGIQE9/GE) after a bolus injection of 2.4 ml sulfohexa-fluoride microbubbles (SonoVue®, Bracco, Italy). Retrospective vascular perfusion was quantified by evaluating the stored DICOM cine loops using the perfusion software QONTRAST® (Bracco, Italy). Over a total penetration depth of 3 cm, every centimeter was analyzed separately. 27 complications were observed. Complete flap loss was only seen in 4 cases, while 23 flaps had to undergo minor revision and survived. RESULTS Regarding the complete flap size, quantitative analysis showed significantly higher perfusion values in patients without complications compared to patients with complications: PEAK 16.5 vs. 10.0 (p = 0.001), TTP 32.6 vs. 22.2 (p = 0.001), RBV: 738.8 vs. 246.2 (p < 0.001), RBF 17.5 vs. 10.1 (p < 0.001) and MTT 43.1 vs. 29.5 (p = 0.001). Analysis of the correlation of the different flap types, age, sex and etiology of the tissue defect to the complication rate showed no statistical correlation. CONCLUSION CEUS was capable of detecting vascular disturbances after flap transplantation. TTP, RBV and MTT seem to be the most accurately parameters and are not susceptible to malfunction during measurement.
Collapse
|