1
|
Fast and Deep Phosphoproteome Analysis with the Orbitrap Astral Mass Spectrometer. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2024:2023.11.21.568149. [PMID: 38045259 PMCID: PMC10690147 DOI: 10.1101/2023.11.21.568149] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/05/2023]
Abstract
Owing to its roles in cellular signal transduction, protein phosphorylation plays critical roles in myriad cell processes. That said, detecting and quantifying protein phosphorylation has remained a challenge. We describe the use of a novel mass spectrometer (Orbitrap Astral) coupled with data-independent acquisition (DIA) to achieve rapid and deep analysis of human and mouse phosphoproteomes. With this method we map approximately 30,000 unique human phosphorylation sites within a half-hour of data collection. The technology was benchmarked to other state-of-the-art MS platforms using both synthetic peptide standards and with EGF-stimulated HeLa cells. We applied this approach to generate a phosphoproteome multi-tissue atlas of the mouse. Altogether, we detected 81,120 unique phosphorylation sites within 12 hours of measurement. With this unique dataset, we examine the sequence, structural, and kinase specificity context of protein phosphorylation. Finally, we highlight the discovery potential of this resource with multiple examples of novel phosphorylation events relevant to mitochondrial and brain biology.
Collapse
|
2
|
The One Hour Human Proteome. Mol Cell Proteomics 2024; 23:100760. [PMID: 38579929 PMCID: PMC11103439 DOI: 10.1016/j.mcpro.2024.100760] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Revised: 03/23/2024] [Accepted: 03/29/2024] [Indexed: 04/07/2024] Open
Abstract
We describe deep analysis of the human proteome in less than 1 h. We achieve this expedited proteome characterization by leveraging state-of-the-art sample preparation, chromatographic separations, and data analysis tools, and by using the new Orbitrap Astral mass spectrometer equipped with a quadrupole mass filter, a high-field Orbitrap mass analyzer, and an asymmetric track lossless (Astral) mass analyzer. The system offers high tandem mass spectrometry acquisition speed of 200 Hz and detects hundreds of peptide sequences per second within data-independent acquisition or data-dependent acquisition modes of operation. The fast-switching capabilities of the new quadrupole complement the sensitivity and fast ion scanning of the Astral analyzer to enable narrow-bin data-independent analysis methods. Over a 30-min active chromatographic method consuming a total analysis time of 56 min, the Q-Orbitrap-Astral hybrid MS collects an average of 4319 MS1 scans and 438,062 tandem mass spectrometry scans per run, producing 235,916 peptide sequences (1% false discovery rate). On average, each 30-min analysis achieved detection of 10,411 protein groups (1% false discovery rate). We conclude, with these results and alongside other recent reports, that the 1-h human proteome is within reach.
Collapse
|
3
|
Paradigm shift in biomarker translation: a pipeline to generate clinical grade biomarker candidates from DIA-MS discovery. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2024:2024.03.20.586018. [PMID: 38562888 PMCID: PMC10983901 DOI: 10.1101/2024.03.20.586018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/04/2024]
Abstract
Clinical biomarker development has been stymied by inaccurate protein quantification from mass spectrometry (MS) discovery data and a prolonged validation process. To mitigate these issues, we created the Targeted Extraction Assessment of Quantification (TEAQ) software package. This innovative tool uses the discovery cohort analysis to select precursors, peptides, and proteins that adhere to established targeted assay criteria. TEAQ was applied to Data-Independent Acquisition MS data from plasma samples acquired on an Orbitrap™ Astral™ MS. Identified precursors were evaluated for linearity, specificity, repeatability, reproducibility, and intra-protein correlation from 11-point loading curves under three throughputs, to develop a resource for clinical-grade targeted assays. From a clinical cohort of individuals with inflammatory bowel disease (n=492), TEAQ successfully identified 1116 signature peptides for 327 quantifiable proteins from 1180 identified proteins. Embedding stringent selection criteria adaptable to targeted assay development into the analysis of discovery data will streamline the transition to validation and clinical studies.
Collapse
|
4
|
Ultra-fast label-free quantification and comprehensive proteome coverage with narrow-window data-independent acquisition. Nat Biotechnol 2024:10.1038/s41587-023-02099-7. [PMID: 38302753 DOI: 10.1038/s41587-023-02099-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Accepted: 12/13/2023] [Indexed: 02/03/2024]
Abstract
Mass spectrometry (MS)-based proteomics aims to characterize comprehensive proteomes in a fast and reproducible manner. Here we present the narrow-window data-independent acquisition (nDIA) strategy consisting of high-resolution MS1 scans with parallel tandem MS (MS/MS) scans of ~200 Hz using 2-Th isolation windows, dissolving the differences between data-dependent and -independent methods. This is achieved by pairing a quadrupole Orbitrap mass spectrometer with the asymmetric track lossless (Astral) analyzer which provides >200-Hz MS/MS scanning speed, high resolving power and sensitivity, and low-ppm mass accuracy. The nDIA strategy enables profiling of >100 full yeast proteomes per day, or 48 human proteomes per day at the depth of ~10,000 human protein groups in half-an-hour or ~7,000 proteins in 5 min, representing 3× higher coverage compared with current state-of-the-art MS. Multi-shot acquisition of offline fractionated samples provides comprehensive coverage of human proteomes in ~3 h. High quantitative precision and accuracy are demonstrated in a three-species proteome mixture, quantifying 14,000+ protein groups in a single half-an-hour run.
Collapse
|
5
|
Elucidating the Mechanism of Multispecific Antibody Aggregation through Subunit Analysis. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2023; 34:2654-2661. [PMID: 37922506 DOI: 10.1021/jasms.3c00206] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/05/2023]
Abstract
Multispecific antibody constructs are quickly becoming more common constructs in biopharmaceuticals to improve specificity and efficacy. While the advent of this technology has led to improved therapeutics, its development has challenged the analytical tools through which these therapeutics are characterized. Moreover, new critical quality attributes, such as aggregation, have challenged the approaches to characterization even further. Herein, we describe a novel native subunit analysis using IdeS and IgdE analyzed by native size exclusion chromatography coupled with mass spectrometry to interrogate the mechanism of aggregation in a multispecific antibody. Digestion by IdeS and IdgE allows for the retention and detection of noncovalent interactions thereafter. Aggregation was localized to single-chain fragment variables (scFvs) wherein a domain swapping mechanism between VH1/VL2 and VH2/VL1 occurs.
Collapse
|
6
|
Parallelized Acquisition of Orbitrap and Astral Analyzers Enables High-Throughput Quantitative Analysis. Anal Chem 2023; 95:15656-15664. [PMID: 37815927 PMCID: PMC10603608 DOI: 10.1021/acs.analchem.3c02856] [Citation(s) in RCA: 16] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Accepted: 09/25/2023] [Indexed: 10/12/2023]
Abstract
The growing trend toward high-throughput proteomics demands rapid liquid chromatography-mass spectrometry (LC-MS) cycles that limit the available time to gather the large numbers of MS/MS fragmentation spectra required for identification. Orbitrap analyzers scale performance with acquisition time and necessarily sacrifice sensitivity and resolving power to deliver higher acquisition rates. We developed a new mass spectrometer that combines a mass-resolving quadrupole, the Orbitrap, and the novel Asymmetric Track Lossless (Astral) analyzer. The new hybrid instrument enables faster acquisition of high-resolution accurate mass (HRAM) MS/MS spectra compared with state-of-the-art mass spectrometers. Accordingly, new proteomics methods were developed that leverage the strengths of each HRAM analyzer, whereby the Orbitrap analyzer performs full scans with a high dynamic range and resolution, synchronized with the Astral analyzer's acquisition of fast and sensitive HRAM MS/MS scans. Substantial improvements are demonstrated over previous methods using current state-of-the-art mass spectrometers.
Collapse
|
7
|
Evaluating the Performance of the Astral Mass Analyzer for Quantitative Proteomics Using Data-Independent Acquisition. J Proteome Res 2023; 22:3290-3300. [PMID: 37683181 PMCID: PMC10563156 DOI: 10.1021/acs.jproteome.3c00357] [Citation(s) in RCA: 13] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Indexed: 09/10/2023]
Abstract
We evaluate the quantitative performance of the newly released Asymmetric Track Lossless (Astral) analyzer. Using data-independent acquisition, the Thermo Scientific Orbitrap Astral mass spectrometer quantifies 5 times more peptides per unit time than state-of-the-art Thermo Scientific Orbitrap mass spectrometers, which have long been the gold standard for high-resolution quantitative proteomics. Our results demonstrate that the Orbitrap Astral mass spectrometer can produce high-quality quantitative measurements across a wide dynamic range. We also use a newly developed extracellular vesicle enrichment protocol to reach new depths of coverage in the plasma proteome, quantifying over 5000 plasma proteins in a 60 min gradient with the Orbitrap Astral mass spectrometer.
Collapse
|
8
|
Protein Coronas on Functionalized Nanoparticles Enable Quantitative and Precise Large-Scale Deep Plasma Proteomics. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.08.28.555225. [PMID: 37693476 PMCID: PMC10491250 DOI: 10.1101/2023.08.28.555225] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/12/2023]
Abstract
Background The wide dynamic range of circulating proteins coupled with the diversity of proteoforms present in plasma has historically impeded comprehensive and quantitative characterization of the plasma proteome at scale. Automated nanoparticle (NP) protein corona-based proteomics workflows can efficiently compress the dynamic range of protein abundances into a mass spectrometry (MS)-accessible detection range. This enhances the depth and scalability of quantitative MS-based methods, which can elucidate the molecular mechanisms of biological processes, discover new protein biomarkers, and improve comprehensiveness of MS-based diagnostics. Methods Investigating multi-species spike-in experiments and a cohort, we investigated fold-change accuracy, linearity, precision, and statistical power for the using the Proteograph™ Product Suite, a deep plasma proteomics workflow, in conjunction with multiple MS instruments. Results We show that NP-based workflows enable accurate identification (false discovery rate of 1%) of more than 6,000 proteins from plasma (Orbitrap Astral) and, compared to a gold standard neat plasma workflow that is limited to the detection of hundreds of plasma proteins, facilitate quantification of more proteins with accurate fold-changes, high linearity, and precision. Furthermore, we demonstrate high statistical power for the discovery of biomarkers in small- and large-scale cohorts. Conclusions The automated NP workflow enables high-throughput, deep, and quantitative plasma proteomics investigation with sufficient power to discover new biomarker signatures with a peptide level resolution.
Collapse
|
9
|
Evaluating the Performance of the Astral Mass Analyzer for Quantitative Proteomics Using Data Independent Acquisition. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.06.03.543570. [PMID: 37398334 PMCID: PMC10312564 DOI: 10.1101/2023.06.03.543570] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/04/2023]
Abstract
We evaluate the quantitative performance of the newly released Asymmetric Track Lossless (Astral) analyzer. Using data independent acquisition, the Thermo Scientific™ Orbitrap™ Astral™ mass spectrometer quantifies 5 times more peptides per unit time than state-of-the-art Thermo Scientific™ Orbitrap™ mass spectrometers, which have long been the gold standard for high resolution quantitative proteomics. Our results demonstrate that the Orbitrap Astral mass spectrometer can produce high quality quantitative measurements across a wide dynamic range. We also use a newly developed extra-cellular vesicle enrichment protocol to reach new depths of coverage in the plasma proteome, quantifying over 5,000 plasma proteins in a 60-minute gradient with the Orbitrap Astral mass spectrometer.
Collapse
|
10
|
Dissecting ribosomal particles throughout the kingdoms of life using advanced hybrid mass spectrometry methods. Nat Commun 2018; 9:2493. [PMID: 29950687 PMCID: PMC6021402 DOI: 10.1038/s41467-018-04853-x] [Citation(s) in RCA: 58] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2018] [Accepted: 05/28/2018] [Indexed: 11/08/2022] Open
Abstract
Biomolecular mass spectrometry has matured strongly over the past decades and has now reached a stage where it can provide deep insights into the structure and composition of large cellular assemblies. Here, we describe a three-tiered hybrid mass spectrometry approach that enables the dissection of macromolecular complexes in order to complement structural studies. To demonstrate the capabilities of the approach, we investigate ribosomes, large ribonucleoprotein particles consisting of a multitude of protein and RNA subunits. We identify sites of sequence processing, protein post-translational modifications, and the assembly and stoichiometry of individual ribosomal proteins in four distinct ribosomal particles of bacterial, plant and human origin. Amongst others, we report extensive cysteine methylation in the zinc finger domain of the human S27 protein, the heptameric stoichiometry of the chloroplastic stalk complex, the heterogeneous composition of human 40S ribosomal subunits and their association to the CrPV, and HCV internal ribosome entry site RNAs.
Collapse
|
11
|
Native mass spectrometry combined with enzymatic dissection unravels glycoform heterogeneity of biopharmaceuticals. Nat Commun 2018; 9:1713. [PMID: 29712889 PMCID: PMC5928108 DOI: 10.1038/s41467-018-04061-7] [Citation(s) in RCA: 70] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2017] [Accepted: 03/30/2018] [Indexed: 12/18/2022] Open
Abstract
Robust manufacturing processes resulting in consistent glycosylation are critical for the efficacy and safety of biopharmaceuticals. Information on glycosylation can be obtained by conventional bottom–up methods but is often limited to the glycan or glycopeptide level. Here, we apply high-resolution native mass spectrometry (MS) for the characterization of the therapeutic fusion protein Etanercept to unravel glycoform heterogeneity in conditions of hitherto unmatched mass spectral complexity. Higher spatial resolution at lower charge states, an inherent characteristic of native MS, represents a key component for the successful revelation of glycan heterogeneity. Combined with enzymatic dissection using a set of proteases and glycosidases, assignment of specific glycoforms is achieved by transferring information from subunit to whole protein level. The application of native mass spectrometric analysis of intact Etanercept as a fingerprinting tool for the assessment of batch-to-batch variability is exemplified and may be extended to demonstrate comparability after changes in the biologic manufacturing process. The specific glycosylation patterns of biological drugs often impact the efficacy and safety of the therapeutic product. Here the authors describe a native mass spectrometry approach that allows the resolution of highly complex glycosylation patterns on large proteins, which they apply to the therapeutic Fc-fusion protein Etanercept.
Collapse
|
12
|
High resolution top-down experimental strategies on the Orbitrap platform. J Proteomics 2018; 175:42-55. [DOI: 10.1016/j.jprot.2017.03.028] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2016] [Revised: 03/08/2017] [Accepted: 03/31/2017] [Indexed: 10/19/2022]
|
13
|
Petroleomics via Orbitrap mass spectrometry with resolving power above 1 000 000 at m/z 200. RSC Adv 2018; 8:6183-6191. [PMID: 35539593 PMCID: PMC9078259 DOI: 10.1039/c7ra12509g] [Citation(s) in RCA: 46] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2017] [Accepted: 01/27/2018] [Indexed: 12/18/2022] Open
Abstract
The performance of the high-field MegaOrbitrap Fourier transform mass spectrometer (FT-MS) with electrospray ionization (ESI) was evaluated to perform petroleum sample characterization via classical petroleomics approaches. Pertinent parameters that underpin the main figures of merit, that is, signal to noise ratios, dynamic range, spectral error, scan speed, mass accuracy and mass resolving power = Rp, and provide subsidies to develop these analyzers were tested. Comparisons are made with data obtained using the most common petroleomics instrument, which is a Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS), that has been used in the last decade in our laboratory for crude oil analysis providing Rp of 340 000 at m/z 400 with transients of 3 s duration, and has been extensively demonstrated to fulfill all major requirements for precise petroleomics investigations. The high-field compact MegaOrbitrap mass analyzer, when operated at an Rp = 840 000 at m/z 400 (Rp > 1 000 000 at m/z 200) with a detection time of 3 s, was found to be well suited for adequate characterization of crude oil. Accurate class classification and mass accuracy below 1 ppm was obtained leading to proper, comprehensive petroleomics characterization. The performance of the high-field MegaOrbitrap Fourier transform mass spectrometer (FT-MS) with electrospray ionization (ESI) was evaluated to perform petroleum sample characterization via classical petroleomics approaches.![]()
Collapse
|
14
|
Top-down analysis of immunoglobulin G isotypes 1 and 2 with electron transfer dissociation on a high-field Orbitrap mass spectrometer. J Proteomics 2017; 159:67-76. [PMID: 28242452 DOI: 10.1016/j.jprot.2017.02.013] [Citation(s) in RCA: 42] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2016] [Revised: 01/22/2017] [Accepted: 02/13/2017] [Indexed: 12/27/2022]
Abstract
The increasing importance of immunoglobulins G (IgGs) as biotherapeutics calls for improved structural characterization methods designed for these large (~150kDa) macromolecules. Analysis workflows have to be rapid, robust, and require minimal sample preparation. In a previous work we showed the potential of Orbitrap Fourier transform mass spectrometry (FTMS) combined with electron transfer dissociation (ETD) for the top-down investigation of an intact IgG1, resulting in ~30% sequence coverage. Here, we describe a top-down analysis of two IgGs1 (adalimumab and trastuzumab) and one IgG2 (panitumumab) performed with ETD on a mass spectrometer equipped with a high-field Orbitrap mass analyzer. For the IgGs1, sequence coverage comparable to the previous results was achieved in a two-fold reduced number of summed transients, which corresponds, taken together with the significantly increased spectra acquisition rate, to ~six-fold improvement in analysis time. Furthermore, we studied the influence of ion-ion interaction times on ETD product ions for IgGs1, and the differences in fragmentation behavior between IgGs1 and IgG2, which present structural differences. Overall, these results reinforce the hypothesis that gas phase dissociation using both energy threshold-based and radical-driven ion activations is directed to specific regions of the polypeptide chains mostly by the location of disulfide bonds. SIGNIFICANCE OF THE STUDY Compared with our previous report, the results presented herein demonstrate the power of technological advances of the next generation Orbitrap™ platform, including the use of a high-field compact (i.e., D20) Orbitrap mass analyzer, and a dedicated manipulation strategy for large protein ions (via their trapping in the HCD collision cell along with reduction of the pressure in the cell). Notably, these important developments became recently commercially available in the top-end Orbitrap platforms under the name of "Protein Mode". Furthermore, we continued exploring the advantages offered by the summation (averaging) of transients (time-domain data) for improving the signal-to-noise ratio of top-down mass spectra. Finally, for the first time we report the application of the hybrid ion activation technique that combines electron transfer dissociation and higher energy collisional dissociation, known as EThcD, on intact monoclonal antibodies. Under these specific instrumental parameters, EThcD produces a partially complementary fragmentation pattern compared to ETD, increasing the overall sequence coverage especially at the protein termini.
Collapse
|
15
|
|
16
|
The Q Exactive HF, a Benchtop mass spectrometer with a pre-filter, high-performance quadrupole and an ultra-high-field Orbitrap analyzer. Mol Cell Proteomics 2014; 13:3698-708. [PMID: 25360005 PMCID: PMC4256516 DOI: 10.1074/mcp.m114.043489] [Citation(s) in RCA: 245] [Impact Index Per Article: 24.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
The quadrupole Orbitrap mass spectrometer (Q Exactive) made a powerful proteomics instrument available in a benchtop format. It significantly boosted the number of proteins analyzable per hour and has now evolved into a proteomics analysis workhorse for many laboratories. Here we describe the Q Exactive Plus and Q Exactive HF mass spectrometers, which feature several innovations in comparison to the original Q Exactive instrument. A low-resolution pre-filter has been implemented within the injection flatapole, preventing unwanted ions from entering deep into the system, and thereby increasing its robustness. A new segmented quadrupole, with higher fidelity of isolation efficiency over a wide range of isolation windows, provides an almost 2-fold improvement of transmission at narrow isolation widths. Additionally, the Q Exactive HF has a compact Orbitrap analyzer, leading to higher field strength and almost doubling the resolution at the same transient times. With its very fast isolation and fragmentation capabilities, the instrument achieves overall cycle times of 1 s for a top 15 to 20 higher energy collisional dissociation method. We demonstrate the identification of 5000 proteins in standard 90-min gradients of tryptic digests of mammalian cell lysate, an increase of over 40% for detected peptides and over 20% for detected proteins. Additionally, we tested the instrument on peptide phosphorylation enriched samples, for which an improvement of up to 60% class I sites was observed.
Collapse
|
17
|
Discrimination of Leucine and Isoleucine in Peptides Sequencing with Orbitrap Fusion Mass Spectrometer. Anal Chem 2014; 86:7017-22. [DOI: 10.1021/ac501200h] [Citation(s) in RCA: 53] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
18
|
Defining the stoichiometry and cargo load of viral and bacterial nanoparticles by Orbitrap mass spectrometry. J Am Chem Soc 2014; 136:7295-9. [PMID: 24787140 PMCID: PMC4046769 DOI: 10.1021/ja502616y] [Citation(s) in RCA: 115] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2013] [Revised: 03/14/2014] [Indexed: 12/12/2022]
Abstract
Accurate mass analysis can provide useful information on the stoichiometry and composition of protein-based particles, such as virus-like assemblies. For applications in nanotechnology and medicine, such nanoparticles are loaded with foreign cargos, making accurate mass information essential to define the cargo load. Here, we describe modifications to an Orbitrap mass spectrometer that enable high mass analysis of several virus-like nanoparticles up to 4.5 MDa in mass. This allows the accurate determination of the composition of virus-like particles. The modified instrument is utilized to determine the cargo load of bacterial encapsulin nanoparticles that were engineered to encapsulate foreign cargo proteins. We find that encapsulin packages from 8 up to 12 cargo proteins, thereby quantifying cargo load but also showing the ensemble spread. In addition, we determined the previously unknown stoichiometry of the three different splice variants of the capsid protein in adeno-associated virus (AAV) capsids, showing that symmetry is broken and assembly is heterogeneous and stochastic. These results demonstrate the potential of high-resolution mass analysis of protein-based nanoparticles, with widespread applications in chemical biology and nanotechnology.
Collapse
|
19
|
From Protein Complexes to Subunit Backbone Fragments: A Multi-stage Approach to Native Mass Spectrometry. Anal Chem 2013; 85:11163-73. [DOI: 10.1021/ac4029328] [Citation(s) in RCA: 133] [Impact Index Per Article: 12.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
20
|
Etablierung eines Orbitrap-Analysators zur Charakterisierung von intakten Antikörpern mittels nativer Massenspektrometrie. Angew Chem Int Ed Engl 2012. [DOI: 10.1002/ange.201206745] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
21
|
Exploring an orbitrap analyzer for the characterization of intact antibodies by native mass spectrometry. Angew Chem Int Ed Engl 2012; 51:12992-6. [PMID: 23172610 DOI: 10.1002/anie.201206745] [Citation(s) in RCA: 118] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2012] [Revised: 10/02/2012] [Indexed: 11/06/2022]
Abstract
Antibody profiling: native mass spectrometry analysis of intact antibodies can be achieved with improved speed, sensitivity, and mass resolution by using a modified orbitrap instrument. Complex mixtures of monoclonal antibodies can be resolved and their glycan "fingerprints" can be profiled. Noncovalent interactions are maintained, thus allowing antibody-antigen binding to be measured.
Collapse
|
22
|
Analysis of intact monoclonal antibody IgG1 by electron transfer dissociation Orbitrap FTMS. Mol Cell Proteomics 2012; 11:1758-67. [PMID: 22964222 DOI: 10.1074/mcp.m112.019620] [Citation(s) in RCA: 124] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023] Open
Abstract
The primary structural information of proteins employed as biotherapeutics is essential if one wishes to understand their structure-function relationship, as well as in the rational design of new therapeutics and for quality control. Given both the large size (around 150 kDa) and the structural complexity of intact immunoglobulin G (IgG), which includes a variable number of disulfide bridges, its extensive fragmentation and subsequent sequence determination by means of tandem mass spectrometry (MS) are challenging. Here, we applied electron transfer dissociation (ETD), implemented on a hybrid Orbitrap Fourier transform mass spectrometer (FTMS), to analyze a commercial recombinant IgG in a liquid chromatography (LC)-tandem mass spectrometry (MS/MS) top-down experiment. The lack of sensitivity typically observed during the top-down MS of large proteins was addressed by averaging time-domain transients recorded in different LC-MS/MS experiments before performing Fourier transform signal processing. The results demonstrate that an improved signal-to-noise ratio, along with the higher resolution and mass accuracy provided by Orbitrap FTMS (relative to previous applications of top-down ETD-based proteomics on IgG), is essential for comprehensive analysis. Specifically, ETD on Orbitrap FTMS produced about 33% sequence coverage of an intact IgG, signifying an almost 2-fold increase in IgG sequence coverage relative to prior ETD-based analysis of intact monoclonal antibodies of a similar subclass. These results suggest the potential application of the developed methodology to other classes of large proteins and biomolecules.
Collapse
|
23
|
Ultra high resolution linear ion trap Orbitrap mass spectrometer (Orbitrap Elite) facilitates top down LC MS/MS and versatile peptide fragmentation modes. Mol Cell Proteomics 2011; 11:O111.013698. [PMID: 22159718 PMCID: PMC3316736 DOI: 10.1074/mcp.o111.013698] [Citation(s) in RCA: 246] [Impact Index Per Article: 18.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Although only a few years old, the combination of a linear ion trap with an Orbitrap analyzer has become one of the standard mass spectrometers to characterize proteins and proteomes. Here we describe a novel version of this instrument family, the Orbitrap Elite, which is improved in three main areas. The ion transfer optics has an ion path that blocks the line of sight to achieve more robust operation. The tandem MS acquisition speed of the dual cell linear ion trap now exceeds 12 Hz. Most importantly, the resolving power of the Orbitrap analyzer has been increased twofold for the same transient length by employing a compact, high-field Orbitrap analyzer that almost doubles the observed frequencies. An enhanced Fourier Transform algorithm—incorporating phase information—further doubles the resolving power to 240,000 at m/z 400 for a 768 ms transient. For top-down experiments, we combine a survey scan with a selected ion monitoring scan of the charge state of the protein to be fragmented and with several HCD microscans. Despite the 120,000 resolving power for SIM and HCD scans, the total cycle time is within several seconds and therefore suitable for liquid chromatography tandem MS. For bottom-up proteomics, we combined survey scans at 240,000 resolving power with data-dependent collision-induced dissociation of the 20 most abundant precursors in a total cycle time of 2.5 s—increasing protein identifications in complex mixtures by about 30%. The speed of the Orbitrap Elite furthermore allows scan modes in which complementary dissociation mechanisms are routinely obtained of all fragmented peptides.
Collapse
|
24
|
Mass spectrometry-based proteomics using Q Exactive, a high-performance benchtop quadrupole Orbitrap mass spectrometer. Mol Cell Proteomics 2011; 10:M111.011015. [PMID: 21642640 PMCID: PMC3284220 DOI: 10.1074/mcp.m111.011015] [Citation(s) in RCA: 582] [Impact Index Per Article: 44.8] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
Abstract
Mass spectrometry-based proteomics has greatly benefitted from enormous advances in high resolution instrumentation in recent years. In particular, the combination of a linear ion trap with the Orbitrap analyzer has proven to be a popular instrument configuration. Complementing this hybrid trap-trap instrument, as well as the standalone Orbitrap analyzer termed Exactive, we here present coupling of a quadrupole mass filter to an Orbitrap analyzer. This “Q Exactive” instrument features high ion currents because of an S-lens, and fast high-energy collision-induced dissociation peptide fragmentation because of parallel filling and detection modes. The image current from the detector is processed by an “enhanced Fourier Transformation” algorithm, doubling mass spectrometric resolution. Together with almost instantaneous isolation and fragmentation, the instrument achieves overall cycle times of 1 s for a top10 higher energy collisional dissociation method. More than 2500 proteins can be identified in standard 90-min gradients of tryptic digests of mammalian cell lysate— a significant improvement over previous Orbitrap mass spectrometers. Furthermore, the quadrupole Orbitrap analyzer combination enables multiplexed operation at the MS and tandem MS levels. This is demonstrated in a multiplexed single ion monitoring mode, in which the quadrupole rapidly switches among different narrow mass ranges that are analyzed in a single composite MS spectrum. Similarly, the quadrupole allows fragmentation of different precursor masses in rapid succession, followed by joint analysis of the higher energy collisional dissociation fragment ions in the Orbitrap analyzer. High performance in a robust benchtop format together with the ability to perform complex multiplexed scan modes make the Q Exactive an exciting new instrument for the proteomics and general analytical communities.
Collapse
|
25
|
A dual pressure linear ion trap Orbitrap instrument with very high sequencing speed. Mol Cell Proteomics 2009; 8:2759-69. [PMID: 19828875 PMCID: PMC2816009 DOI: 10.1074/mcp.m900375-mcp200] [Citation(s) in RCA: 361] [Impact Index Per Article: 24.1] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
Since its introduction a few years ago, the linear ion trap Orbitrap (LTQ Orbitrap) instrument has become a powerful tool in proteomics research. For high resolution mass spectrometry measurements ions are accumulated in the linear ion trap and passed on to the Orbitrap analyzer. Simultaneously with acquisition of this signal, the major peaks are isolated in turn, fragmented and recorded at high sensitivity in the linear ion trap, combining the strengths of both mass analyzer technologies. Here we describe a next generation LTQ Orbitrap system termed Velos, with significantly increased sensitivity and scan speed. This is achieved by a vacuum interface using a stacked ring radio frequency ion guide with 10-fold higher transfer efficiency in MS/MS mode and 3–5-fold in full scan spectra, by a dual pressure ion trap configuration, and by reduction of overhead times between scans. The first ion trap efficiently captures and fragments ions at relatively high pressure whereas the second ion trap realizes extremely fast scan speeds at reduced pressure. Ion injection times for MS/MS are predicted from full scans instead of performing automatic gain control scans. Together these improvements routinely enable acquisition of up to ten fragmentation spectra per second. Furthermore, an improved higher-energy collisional dissociation cell with increased ion extraction capabilities was implemented. Higher-collision energy dissociation with high mass accuracy Orbitrap readout is as sensitive as ion trap MS/MS scans in the previous generation of the instrument.
Collapse
|
26
|
Lung alveolar proteomics of bronchoalveolar lavage from a pulmonary alveolar proteinosis patient using high-resolution FTICR mass spectrometry. Anal Bioanal Chem 2007; 389:1075-85. [PMID: 17579843 DOI: 10.1007/s00216-007-1403-z] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2007] [Revised: 05/17/2007] [Accepted: 05/25/2007] [Indexed: 10/23/2022]
Abstract
High-resolution Fourier transform ion cyclotron resonance (FTICR) mass spectrometry was developed and applied to the proteome analysis of bronchoalveolar lavage fluid (BALF) from a patient with pulmonary alveolar proteinosis. With use of 1-D and 2-D gel electrophoresis, surfactant protein A (SP-A) and other surfactant-related lung alveolar proteins were efficiently separated and identified by matrix-assisted laser desorption/ionization FTICR mass spectrometry . Low molecular mass BALF proteins were separated using a gradient 2-D gel. An efficient extraction/precipitation system was developed and used for the enrichment of surfactant proteins. The result of the BALF proteome analysis show the presence of several isoforms of SP-A, in which an N-non-glycosylierte form and several proline hydroxylations were identified. Furthermore, a number of protein spots were found to contain a mixture of proteins unresolved by 2-D gel electrophoresis, illustrating the feasibility of high-resolution mass spectrometry to provide identifications of proteins that remain unseparated in 2-D gels even upon extended pH gradients.
Collapse
|
27
|
Determination of phosphorus-, copper-, and zinc-containing human brain proteins by LA-ICPMS and MALDI-FTICR-MS. Anal Chem 2007; 77:5851-60. [PMID: 16159114 DOI: 10.1021/ac0506579] [Citation(s) in RCA: 71] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Human brain proteins containing phosphorus, copper, and zinc were detected directly in protein spots in gels of a human brain sample after separation by two-dimensional gel electrophoresis using laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS). A powerful laser ablation system with cooled laser ablation chamber was coupled to a double-focusing sector field ICPMS. The separated protein spots in 2D gels were fast screened using the optimized microanalytical LA-ICPMS technique measured at medium mass resolution with a focused laser beam (wavelength, 213 nm; diameter of laser crater, 50 mum; and laser power density, 3 x 10(9) W cm(-2)) with respect to selected three essential elements. Of 176 protein spots in 2D gel from a human brain sample, phosphorus, copper, and zinc were detected in 31, 43, and 49 protein spots, respectively. For the first time, uranium as a naturally occurring radioactive element was found in 20 selected protein spots. The detection limits for P, S, Cu, Zn and U were determined in singular protein spots with 0.0013, 1.29, 0.029, 0.063, and 0.000 01 mg g(-1), respectively. A combination of LA-ICPMS with matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry (MALDI-FTICR-MS) was applied for the identification of selected protein spots from human brain protein separated by 2D gel electrophoresis. Combining MALDI-FTICR-MS for the structure analysis of metal- and phosphorus-containing human brain proteins with LA-ICPMS, the direct analysis of heteroelements on separated proteins in 2D gels can be performed. For quantification of analytical LA-ICPMS data, the number of sulfur atoms per protein (and following the sulfur concentration) determined by MALDI-FTICR-MS was used for internal standardization. From the known sulfur concentration in protein, the concentration of other heteroelements was calculated. In addition, the number of phosphorylation and the phosphorylation sites of phosphorylated proteins in the human brain sample detected by LA-ICPMS were determined by MALDI-FTICR-MS. This technique allows the study of posttranslational modifications in human brain proteins.
Collapse
|
28
|
Structural characterization of the human eukaryotic initiation factor 3 protein complex by mass spectrometry. Mol Cell Proteomics 2007; 6:1135-46. [PMID: 17322308 DOI: 10.1074/mcp.m600399-mcp200] [Citation(s) in RCA: 112] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
Protein synthesis in mammalian cells requires initiation factor eIF3, an approximately 800-kDa protein complex that plays a central role in binding of initiator methionyl-tRNA and mRNA to the 40 S ribosomal subunit to form the 48 S initiation complex. The eIF3 complex also prevents premature association of the 40 and 60 S ribosomal subunits and interacts with other initiation factors involved in start codon selection. The molecular mechanisms by which eIF3 exerts these functions are poorly understood. Since its initial characterization in the 1970s, the exact size, composition, and post-translational modifications of mammalian eIF3 have not been rigorously determined. Two powerful mass spectrometric approaches were used in the present study to determine post-translational modifications that may regulate the activity of eIF3 during the translation initiation process and to characterize the molecular structure of the human eIF3 protein complex purified from HeLa cells. In the first approach, the bottom-up analysis of eIF3 allowed for the identification of a total of 13 protein components (eIF3a-m) with a sequence coverage of approximately 79%. Furthermore 29 phosphorylation sites and several other post-translational modifications were unambiguously identified within the eIF3 complex. The second mass spectrometric approach, involving analysis of intact eIF3, allowed the detection of a complex with each of the 13 subunits present in stoichiometric amounts. Using tandem mass spectrometry four eIF3 subunits (h, i, k, and m) were found to be most easily dissociated and therefore likely to be on the periphery of the complex. It is noteworthy that none of these four subunits were found to be phosphorylated. These data raise interesting questions about the function of phosphorylation as it relates to the core subunits of the complex.
Collapse
|
29
|
Detection and purification of tyrosine-sulfated proteins using a novel anti-sulfotyrosine monoclonal antibody. J Biol Chem 2006; 281:37877-87. [PMID: 17046811 PMCID: PMC1764208 DOI: 10.1074/jbc.m609398200] [Citation(s) in RCA: 68] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
Protein tyrosine O-sulfation is a post-translational modification mediated by one of two Golgi tyrosylprotein sulfotransferases (TPST1 and TPST2) that catalyze the transfer of sulfate to tyrosine residues in secreted and transmembrane proteins. Tyrosine sulfation plays a role in protein-protein interactions in several well defined systems. Although dozens of tyrosine-sulfated proteins are known, many more are likely to exist and await description. Advancing our understanding of the importance of tyrosine sulfation in biological systems requires the development of new tools for the detection and study of tyrosine-sulfated proteins. We have developed a novel anti-sulfotyrosine monoclonal antibody (called PSG2) that binds with high affinity and exquisite specificity to sulfotyrosine residues in peptides and proteins independently of sequence context. We show that it can detect tyrosine-sulfated proteins in complex biological samples and can be used as a probe to assess the role of tyrosine sulfation in protein function. We also demonstrate the utility of PSG2 in the purification of tyrosine-sulfated proteins from crude tissue samples. Finally, Western blot analysis using PSG2 showed that certain sperm/epididymal proteins are undersulfated in Tpst2(-/-) mice. This indicates that TPST1 and TPST2 have distinct macromolecular substrate specificities and provides clues as to the molecular mechanism of the infertility of Tpst2(-/-) males. PSG2 should be widely applicable for identification of tyrosine-sulfated proteins in other systems and organisms.
Collapse
|
30
|
N-glycan structures and N-glycosylation sites of mouse soluble intercellular adhesion molecule-1 revealed by MALDI-TOF and FTICR mass spectrometry. Glycobiology 2006; 16:1033-44. [PMID: 16877748 DOI: 10.1093/glycob/cwl032] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Intercellular adhesion molecule-1 (ICAM-1) is a heavily N-glycosylated transmembrane protein comprising five extracellular Ig-like domains. The soluble isoform of ICAM-1 (sICAM-1), consisting of its extracellular part, is elevated in the cerebrospinal fluid of patients with severe brain trauma. In mouse astrocytes, recombinant mouse sICAM-1 induces the production of the CXC chemokine macrophage inflammatory protein-2 (MIP-2). MIP-2 induction is glycosylation dependent, as it is strongly enhanced when sICAM-1 carries sialylated, complex-type N-glycans as synthesized by wild-type Chinese hamster ovary (CHO) cells. The present study was aimed at elucidating the N-glycosylation of mouse sICAM-1 expressed in wild-type CHO cells with regard to sialylation, N-glycan profile, and N-glycosylation sites. Ion-exchange chromatography and matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) of the released N-glycans showed that sICAM-1 mostly carried di- and trisialylated complex-type N-glycans with or without one fucose. In some sialylated N-glycans, one N-acetylneuraminic acid was replaced by N-glycolylneuraminic acid, and approximately 4% carried a higher number of sialic acid residues than of antennae. The N-glycosylation sites of mouse sICAM-1 were analyzed by MALDI-Fourier transform ion cyclotron resonance (FTICR)-MS and nanoLC-ESI-FTICR-MS of tryptic digests of mouse sICAM-1 expressed in the Lec1 mutant of CHO cells. All nine consensus sequences for N-glycosylation were found to be glycosylated. These results show that the N-glycans that enhance the MIP-2-inducing activity of mouse sICAM-1 are mostly di- and trisialylated complex-type N-glycans including a small fraction carrying more sialic acid residues than antennae and that the nine N-glycosylation sites of mouse sICAM-1 are all glycosylated.
Collapse
|
31
|
Structural Characterization and Identification of Post‐Translational Modifications of Human Eukaryotic Initiation Factor 3 (eIF3) by FTICR Mass Spectrometry. FASEB J 2006. [DOI: 10.1096/fasebj.20.4.a528-c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
32
|
High resolution mass spectrometric alveolar proteomics: identification of surfactant protein SP-A and SP-D modifications in proteinosis and cystic fibrosis patients. Proteomics 2005; 4:2300-9. [PMID: 15274124 DOI: 10.1002/pmic.200400855] [Citation(s) in RCA: 36] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
In the present study, one- and two-dimensional gel electrophoresis combined with high resolution Fourier transform-ion cyclotron resonance mass spectrometry (FT-ICR MS) have been applied as powerful approaches for the proteome analysis of surfactant proteins SP-A and SP-D, including identification of structurally modified and truncation forms, in bronchoalveolar lavage fluid from patients with cystic fibrosis, chronic bronchitis and pulmonary alveolar proteinosis. Highly sensitive micropreparation techniques were developed for matrix-assisted laser desorption/ionization (MALDI) FT-ICR MS analysis which provided the identification of surfactant proteins at very low levels. Owing to the high resolution, FT-ICR MS was found to provide substantial advantages for the structural identification of surfactant proteins from complex biological matrices with high mass determination accuracy. Several protein bands corresponding to SP-A and SP-D were identified by MALDI-FT-ICR MS after electrophoretic separation by one- and two-dimensional gel electrophoresis, and provided the identification of structural modifications (hydroxy-proline) and degradation products. The high resolution mass spectrometric proteome analysis should facilitate the unequivocal identification of subunits, aggregations, modifications and degradation products of surfactant proteins and hence contribute to the understanding of the mechanistic basis of lung disease pathogenesis.
Collapse
|
33
|
Abstract
The cellular prion protein (PrPc) represents the substrate for generation of conformational aberrant PrP isoforms which occur in human and animal prion diseases. The published two-dimensional maps of human PrPc show a vast microheterogeneity of this glycoprotein. The main goal of this project was to develop a highly specific immunoaffinity reactor for qualitative analysis of PrP cellular isoforms isolated from brain homogenate, cerebrospinal fluid and other tissues. New techniques for affinity proteomics, carriers and immobilization chemistry were applied. The choice of matrix (chemical and magnetic properties, particle size and distribution, porosity) was the key factor that influenced the quality of the reactor and the nature of final applications. Mouse anti-prion IgGs directed to N-terminal and C-terminal epitopes (residues 23-40 and 147-165) were grafted in different manners to magnetic micro- and nanoparticles particularly developed for micro-CHIP application. High operational and storage stability of affinity reactors with minimized nonspecific absorption were achieved. The quality of the immunoreactors was confirmed by sodium dodecyl sulfate-polyacrylamide gel electrophoresis followed by immunoblotting and by two-dimensional electrophoresis.
Collapse
|
34
|
Abstract
We present the state-of-the-art in miniaturized sample preparation, immunoassays, one-dimensional and multidimensional analyte separations, and coupling of microdevices with electrospray ionization-mass spectrometry. Hyphenation of these different techniques and their relevance to proteomics will be discussed. In particular, we will show that analytical performances of microfluidic analytical systems are already close to fulfill the requirements for proteomics, and that miniaturization results at the same time in a dramatic increase in analysis throughput. Throughout this review, some examples of analytical operations that cannot be achieved without microfluidics will be emphasized. Finally, conditions for the spreading of microanalytical systems in routine proteomic labs will be discussed.
Collapse
|
35
|
Identification of N -glycosylation sites of the murine neural cell adhesion molecule NCAM by MALDI-TOF and MALDI-FTICR mass spectrometry. Anal Bioanal Chem 2004; 378:1129-35. [PMID: 14658030 DOI: 10.1007/s00216-003-2383-2] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2003] [Revised: 10/27/2003] [Accepted: 10/29/2003] [Indexed: 10/26/2022]
Abstract
Mass spectrometry has been shown in recent years to be a powerful tool to determine accurate molecular masses and sequences of peptides and proteins and post-translational modifications such as glycosylation, phosphorylation, and sulfation. For glycosylation, it has been increasingly recognized to be of pivotal importance to identify whether potential glycosylation sites are actually modified by glycans, because functions of proteins may be modulated or depend on the presence of glycans at specific sites. Several recent reports have established that mass spectrometric techniques such as matrix-assisted laser desorption/ionization or electrospray ionization mass spectrometry (MALDI-TOF or ESI-MS, respectively) with or without preceding HPLC and in combination with PNGase F treatment are suited to analyze whether consensus sequences for N-glycosylation are glycosylated or not. Here we report the mass spectrometric analysis of the six potential N-glycosylation sites of the neural cell adhesion molecule NCAM from adult mouse brain. Unmodified peptides and glycopeptides each carrying a single glycosylation site were generated from NCAM by AspN and trypsin treatment and submitted to reversed-phase HPLC with or without prior enzymatic release of N-glycans. The resulting peptides were analyzed by MALDI-TOF-MS. In addition, high-resolution Fourier transform-ion cyclotron resonance (MALDI-FTICR) mass spectrometry was performed after in-gel deglycosylation and subsequent trypsin digestion. By using these procedures all six consensus sequences were shown to be glycosylated; the observation of an unmodified peptide with the consensus sequence N-1 indicates only partial glycosylation at this site.
Collapse
|
36
|
"Affinity-proteomics": direct protein identification from biological material using mass spectrometric epitope mapping. Anal Bioanal Chem 2004; 378:1102-11. [PMID: 12955276 DOI: 10.1007/s00216-003-2159-8] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2003] [Revised: 06/30/2003] [Accepted: 07/04/2003] [Indexed: 11/28/2022]
Abstract
We describe here a new approach for the identification of affinity-bound proteins by proteolytic generation and mass spectrometric analysis of their antibody bound epitope peptides (epitope excision). The cardiac muscle protein troponin T was chosen as a protein antigen because of its diagnostic importance in myocardial infarct, and its previously characterised epitope structure. Two monoclonal antibodies (IgG1-1B10 and IgG1-11.7) raised against intact human troponin T were found to be completely cross reactive with bovine heart troponin T. A combination of immuno-affinity isolation, partial proteolytic degradation (epitope excision), mass spectrometric peptide mapping, and database analysis was used for the direct identification of Tn T from bovine heart cell lysate. Selective binding of the protein was achieved by addition of bovine heart cell lysate to the Sepharose-immobilised monoclonal antibodies, followed by removal of supernatant material containing unbound protein. While still bound to the affinity matrix the protein was partially degraded thereby generating a set of affinity-bound, overlapping peptide fragments comprising the epitope. Following dissociation from the antibody the epitope peptides were analysed by matrix assisted laser desorption-ionisation (MALDI) and electrospray-ionisation (ESI) mass spectrometry. The peptide masses identified by mass spectrometry were used to perform an automated database search, combined with a search for a common "epitope motif". This procedure resulted in the unequivocal identification of the protein from biological material with only a minimum number of peptide masses, and requiring only limited mass-determination accuracy. The dramatic increase of selectivity for identification of the protein by combining the antigen-antibody specificity with the redundancy of peptide sequences renders this "affinity-proteomics" approach a powerful tool for mass spectrometric identification of proteins from biological material.
Collapse
|
37
|
High resolution proteome analysis of cryoglobulins using Fourier transform-ion cyclotron resonance mass spectrometry. Proteomics 2003; 3:1425-33. [PMID: 12923767 DOI: 10.1002/pmic.200300482] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Cryoglobulins are cold-precipitable serum immunoglobulins associated with a number of infectious, autoimmune and neoplastic disorders such as hepatitis C, Waldenström's macroglobulinemia, multiple myeloma, chronic lymphocytic leukemia, and rheumatoid arthritis. The mechanism(s) of cryoprecipitation has remained obscure hitherto, which has prompted recent intensive efforts on the identification of cryoglobulin components. In the present study, two-dimensional gel electrophoresis (2-DE) combined with high resolution Fourier transform-ion cyclotron resonance (FT-ICR) mass spectrometry has been applied as a powerful approach for the analysis of cryoglobulins. While FT-ICR mass spectrometry has been shown to enable the high resolution identification and structure analysis of biopolymers using both electrospray (ESI) and matrix-assisted laser desorption ionization (MALDI), the recently developed MALDI-FT-ICR source is shown here to provide high (sub-ppm) mass determination accuracy and isotopic fine structure as particular advantages in the identification of proteins. The main protein components in a serum cryoprecipitate from a patient with hepatitis C virus (HCV) infection and presenting type II cryogobulinemia are immunoglobulin (Ig)M and IgG which were identified by MALDI-FT-ICR MS analysis after separation by 2-DE as mu- and gamma-heavy chains, kappa- and lambda-light chains, and J-chains. Furthermore, complementarity determining regions CDR1 and CDR2 from monoclonal IgM-RF variable region (V)L were directly identified using accurate mass determinations by FT-ICR-MS. The presence of Spalpha was ascertained as an IgM-associated protein in the serum cryoprecipitate from a patient with HCV infection.
Collapse
|
38
|
Thin-Chip Microspray System for High-Performance Fourier-Transform Ion-Cyclotron Resonance Mass Spectrometry of Biopolymers. Angew Chem Int Ed Engl 2003. [DOI: 10.1002/anie.200390050] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
39
|
Ein Chip-Mikrospraysystem für die hochauflösende Fourier-Transformations-Ionenzyklotronresonanz-Massenspektrometrie von Biopolymeren. Angew Chem Int Ed Engl 2003. [DOI: 10.1002/ange.200390020] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
40
|
Thin-chip microspray system for high-performance Fourier-transform ion-cyclotron resonance mass spectrometry of biopolymers. Angew Chem Int Ed Engl 2003; 42:54-58. [PMID: 19757589] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
|