1
|
Organisation of paediatric echocardiography laboratories and governance of echocardiography services and training in Europe: current status, disparities and potential solutions. A survey from the Association for European Paediatric and Congenital Cardiology (AEPC) imaging working group - CORRIGENDUM. Cardiol Young 2024:1. [PMID: 38557389 DOI: 10.1017/s1047951124000519] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/04/2024]
|
2
|
Design and implementation of multicenter pediatric and congenital studies with cardiovascular magnetic resonance: Big data in smaller bodies. J Cardiovasc Magn Reson 2024; 26:101041. [PMID: 38527706 PMCID: PMC10990896 DOI: 10.1016/j.jocmr.2024.101041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 03/12/2024] [Accepted: 03/20/2024] [Indexed: 03/27/2024] Open
Abstract
Cardiovascular magnetic resonance (CMR) has become the reference standard for quantitative and qualitative assessment of ventricular function, blood flow, and myocardial tissue characterization. There is a preponderance of large CMR studies and registries in adults; However, similarly powered studies are lacking for the pediatric and congenital heart disease (PCHD) population. To date, most CMR studies in children are limited to small single or multicenter studies, thereby limiting the conclusions that can be drawn. Within the PCHD CMR community, a collaborative effort has been successfully employed to recognize knowledge gaps with the aim to embolden the development and initiation of high-quality, large-scale multicenter research. In this publication, we highlight the underlying challenges and provide a practical guide toward the development of larger, multicenter initiatives focusing on PCHD populations, which can serve as a model for future multicenter efforts.
Collapse
|
3
|
Organisation of paediatric echocardiography laboratories and governance of echocardiography services and training in Europe: current status, disparities, and potential solutions. A survey from the Association for European Paediatric and Congenital Cardiology (AEPC) imaging working group. Cardiol Young 2024:1-9. [PMID: 38439642 DOI: 10.1017/s1047951124000131] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/06/2024]
Abstract
BACKGROUND There is limited data on the organisation of paediatric echocardiography laboratories in Europe. METHODS A structured and approved questionnaire was circulated across all 95 Association for European Paediatric and Congenital Cardiology affiliated centres. The aims were to evaluate: (1) facilities in paediatric echocardiography laboratories across Europe, (2) accredited laboratories, (3) medical/paramedical staff employed, (4) time for echocardiographic studies and reporting, and (5) training, teaching, quality improvement, and research programs. RESULTS Respondents from forty-three centres (45%) in 22 countries completed the survey. Thirty-six centres (84%) have a dedicated paediatric echocardiography laboratory, only five (12%) of which reported they were European Association of Cardiovascular Imaging accredited. The median number of echocardiography rooms was three (range 1-12), and echocardiography machines was four (range 1-12). Only half of all the centres have dedicated imaging physiologists and/or nursing staff, while the majority (79%) have specialist imaging cardiologist(s). The median (range) duration of time for a new examination was 45 (20-60) minutes, and for repeat examination was 20 (5-30) minutes. More than half of respondents (58%) have dedicated time for reporting. An organised training program was present in most centres (78%), 44% undertake quality assurance, and 79% perform research. Guidelines for performing echocardiography were available in 32 centres (74%). CONCLUSION Facilities, staffing levels, study times, standards in teaching/training, and quality assurance vary widely across paediatric echocardiography laboratories in Europe. Greater support and investment to facilitate improvements in staffing levels, equipment, and governance would potentially improve European paediatric echocardiography laboratories.
Collapse
|
4
|
Dobutamine Stress Cardiovascular Magnetic Resonance Derived 2-Dimension Feature Tracking Strain Analysis in Pediatric Population with Anomalous Aortic Origin of Right Coronary Artery. Pediatr Cardiol 2024; 45:520-528. [PMID: 38233665 DOI: 10.1007/s00246-023-03401-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/17/2023] [Accepted: 12/28/2023] [Indexed: 01/19/2024]
Abstract
Anomalous aortic origin of right coronary artery (AAORCA) is associated with myocardial ischemia and sudden cardiac arrest/death. Risk stratification remains challenging and relies upon provocative test results. This study describes the utility of dobutamine stress cardiovascular magnetic resonance (DSCMR) and potential benefit of strain analysis in children with AAORCA. All patients less than 21 years of age with AAORCA who underwent DSCMR between July 2018 and December 2022 were included. Visual wall motion abnormalities (VWMA) at rest and during protocolized increments of dobutamine infusion were assessed. Regional and global left ventricular circumferential (GCS) and radial (GRS) strain using 2-dimension Feature tracking (2D-FT) analysis (cvi42, Circle Cardiovascular Imaging Inc.) were calculated at rest and peak response. Of the total 54 DSCMR studies performed in 51 children with median age (IQR) of 13.5 (11-15) years, FT analysis was reliably performed in 52 (96%) studies. None had VWMA. The absolute change in GCS and GRS from rest to peak dobutamine stress was 4% (1-6%) and 11% (4-18%), respectively. There was no significant difference in GCS and GRS in patients with exertional symptoms vs no/non-exertional symptoms as well as between those considered to be high-risk vs low-risk anatomical features. DSCMR-derived 2D-FT strain analysis is feasible to assess myocardial deformation in children with AAORCA and may enhance this method of provocative testing. Although there were no statically significant differences in GCS and GRS values between high and low-risk subgroups, the absolute change in GCS between rest and peak stress is diminished when compared to normal adult reports.
Collapse
|
5
|
Artificial Intelligence to derive aligned strain in cine CMR to detect patients with myocardial fibrosis: an open and scrutinizable approach. RESEARCH SQUARE 2024:rs.3.rs-3785677. [PMID: 38260274 PMCID: PMC10802696 DOI: 10.21203/rs.3.rs-3785677/v1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/24/2024]
Abstract
Cine Cardiac Magnetic Resonance (CMR) is the gold standard for cardiac function evaluation, incorporating ejection fraction (EF) and strain as vital indicators of abnormal deformation. Rare pathologies like Duchenne muscular dystrophies (DMD) are monitored with repeated late gadolinium-enhanced (LGE) CMR for identification of myocardial fibrosis. However, it is judicious to reduce repeated gadolinium exposure and rather employ strain analysis from cine CMR. This solution is limited so far since full strain curves are not comparable between individual cardiac cycles and current practice mainly neglects diastolic deformation patterns. Our novel Deep Learning-based approach derives strain values aligned by key frames throughout the cardiac cycle. In a reproducibility scenario (57+82 patients), our results reveal five times more significant differences (22 vs. 4) between patients with scar and without, enhancing scar detection by +30%, improving detection of patients with preserved EF by +61%, with an overall sensitivity/specificity of 82/81%.
Collapse
|
6
|
Tolerability and efficacy of a reduced dose adenosine stress cardiac magnetic resonance protocol under general anesthesia in infants and children. Pediatr Radiol 2023; 53:2188-2196. [PMID: 37563320 DOI: 10.1007/s00247-023-05738-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/05/2023] [Revised: 07/28/2023] [Accepted: 08/01/2023] [Indexed: 08/12/2023]
Abstract
BACKGROUND Intravenous adenosine induces pharmacological stress by causing vasodilatation and thus carries the risk of severe hypotension when combined with vasodilatory effects of anesthetic agents. OBJECTIVE This study describes our experience with a reduced dose adenosine cardiac magnetic resonance imaging (MRI) protocol in young children under general anesthesia (GA). MATERIALS AND METHODS This is a retrospective report of all patients from birth to 18 years who underwent adenosine stress cardiac MRI under GA between August 2018 and November 2022. Based on our anecdotal experience of severe adverse effects in patients receiving adenosine infusion under GA and in discussion with the pediatric anesthesia team, we developed a modified protocol starting at a dose of 110 mcg/kg/min with incremental escalation to a full dose of 140 mcg/kg/min to achieve desired hemodynamic effect. RESULTS Twenty-two children (mean age 6.5 years, mean weight 28 kg) satisfied the inclusion criteria. The diagnoses included Kawasaki disease (7), anomalous aortic origin of left coronary artery (3), anomalous aortic origin of right coronary artery (2), coronary fistula (3), repaired d-transposition of great arteries (2), repaired anomalous left coronary artery from pulmonary artery (2), repaired truncus arteriosus with left coronary artery occlusion (1), extracardiac-Fontan with left coronary artery myocardial bridge (1), and post heart transplantation (1). Nine patients needed dose escalation beyond 110 mcg/kg/min. Two patients had transient hypotension during testing (systemic blood pressure drop > 25 mmHg). No patient developed significant heart block or bronchospasm. Six patients (repeat study in one) demonstrated inducible perfusion defects (27%) on stress perfusion sequences-5 of whom had confirmed significant coronary abnormalities on angiography or direct surgical inspection. CONCLUSION A reduced/incremental dose adenosine stress cardiac MRI protocol under GA in children is safe and feasible. This avoids severe hypotension which is both unsafe and may result in inaccurate data.
Collapse
|
7
|
Time-Synchronization of Interventional Cardiovascular Magnetic Resonance Data Using a Biomechanical Model for Pressure-Volume Loop Analysis. J Magn Reson Imaging 2023; 57:320-323. [PMID: 35567583 DOI: 10.1002/jmri.28216] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2022] [Accepted: 04/15/2022] [Indexed: 02/04/2023] Open
|
8
|
Le Cœur en Sabot: shape associations with adverse events in repaired tetralogy of Fallot. J Cardiovasc Magn Reson 2022; 24:46. [PMID: 35922806 PMCID: PMC9351245 DOI: 10.1186/s12968-022-00877-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Accepted: 07/20/2022] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND Maladaptive remodelling mechanisms occur in patients with repaired tetralogy of Fallot (rToF) resulting in a cycle of metabolic and structural changes. Biventricular shape analysis may indicate mechanisms associated with adverse events independent of pulmonary regurgitant volume index (PRVI). We aimed to determine novel remodelling patterns associated with adverse events in patients with rToF using shape and function analysis. METHODS Biventricular shape and function were studied in 192 patients with rToF (median time from TOF repair to baseline evaluation 13.5 years). Linear discriminant analysis (LDA) and principal component analysis (PCA) were used to identify shape differences between patients with and without adverse events. Adverse events included death, arrhythmias, and cardiac arrest with median follow-up of 10 years. RESULTS LDA and PCA showed that shape characteristics pertaining to adverse events included a more circular left ventricle (LV) (decreased eccentricity), dilated (increased sphericity) LV base, increased right ventricular (RV) apical sphericity, and decreased RV basal sphericity. Multivariate LDA showed that the optimal discriminative model included only RV apical ejection fraction and one PCA mode associated with a more circular and dilated LV base (AUC = 0.77). PRVI did not add value, and shape changes associated with increased PRVI were not predictive of adverse outcomes. CONCLUSION Pathological remodelling patterns in patients with rToF are significantly associated with adverse events, independent of PRVI. Mechanisms related to incident events include LV basal dilation with a reduced RV apical ejection fraction.
Collapse
|
9
|
SCMR expert consensus statement for cardiovascular magnetic resonance of acquired and non-structural pediatric heart disease. J Cardiovasc Magn Reson 2022; 24:44. [PMID: 35864534 PMCID: PMC9302232 DOI: 10.1186/s12968-022-00873-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2022] [Accepted: 06/24/2022] [Indexed: 12/14/2022] Open
Abstract
Cardiovascular magnetic resonance (CMR) is widely used for diagnostic imaging in the pediatric population. In addition to structural congenital heart disease (CHD), for which published guidelines are available, CMR is also performed for non-structural pediatric heart disease, for which guidelines are not available. This article provides guidelines for the performance and reporting of CMR in the pediatric population for non-structural ("non-congenital") heart disease, including cardiomyopathies, myocarditis, Kawasaki disease and systemic vasculitides, cardiac tumors, pericardial disease, pulmonary hypertension, heart transplant, and aortopathies. Given important differences in disease pathophysiology and clinical manifestations as well as unique technical challenges related to body size, heart rate, and sedation needs, these guidelines focus on optimization of the CMR examination in infants and children compared to adults. Disease states are discussed, including the goals of CMR examination, disease-specific protocols, and limitations and pitfalls, as well as newer techniques that remain under development.
Collapse
|
10
|
Improved catheter tracking during cardiovascular magnetic resonance-guided cardiac catheterization using overlay visualization. J Cardiovasc Magn Reson 2022; 24:32. [PMID: 35650624 PMCID: PMC9161533 DOI: 10.1186/s12968-022-00863-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Accepted: 04/06/2022] [Indexed: 11/07/2022] Open
Abstract
INTRODUCTION Cardiovascular magnetic resonance (CMR)-guided cardiac catheterization is becoming more widespread due to the ability to acquire both functional CMR measurements and diagnostic catheterization data without exposing patients to ionizing radiation. However, the real-time imaging sequences used for catheter guidance during these procedures are limited in resolution and the anatomical detail they can provide. In this study, we propose a passive catheter tracking approach which simultaneously improves catheter tracking and visualization of the anatomy. METHODS 60 patients with congenital heart disease underwent CMR-guided cardiac catheterization on a 1.5T CMR scanner (Ingenia, Philips Healthcare, Best the Netherlands) using the Philips iSuite system. The proposed T1-overlay technique uses a commercially available heavily T1-weighted sequence to image the catheter, and overlays it on a high-resolution 3D dataset within iSuite in real-time. Suppressed tissue in the real-time images enables the use of a thick imaging slab to assist in tracking of the catheter. Improvement in catheter visualization time was compared between T1-overlay and the conventional invasive CMR (iCMR) balanced steady state free precession (bSSFP) sequence. This technique also enabled selective angiography visualization for real-time evaluation of blood flow dynamics (such as pulmonary transit time), similar to direct contrast injection under standard fluoroscopy. Estimates of pulmonary transit time using iCMR were validated using x-ray fluoroscopy in 16 patients. RESULTS The T1-overlay approach significantly increased the time that the catheter tip was kept in view by the technologist compared to the bSSFP sequence conventionally used for iCMR. The resulting images received higher ratings for blood/balloon contrast, anatomy visualization, and overall suitability for iCMR guidance by three cardiologists. iCMR selective angiography using T1-overlay also provided accurate estimates of pulmonary transit time that agreed well with x-ray fluoroscopy. CONCLUSION We demonstrate a new passive catheter tracking technique using the iSuite platform that improves visualization of the catheter and cardiac anatomy. These improvements significantly increase the time that the catheter tip is seen throughout the procedure. We also demonstrate the feasibility of iCMR selective angiography for the measurement of pulmonary transit time.
Collapse
|
11
|
Correction to: Left Ventricular Torsion Obtained Using Equilibrated Warping in Patients with Repaired Tetralogy of Fallot. Pediatr Cardiol 2022; 43:248. [PMID: 34751798 DOI: 10.1007/s00246-021-02766-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
12
|
Estimating the optimal timing of surgery by imputing potential outcomes. Stat Med 2021; 40:6900-6917. [PMID: 34636065 PMCID: PMC8671372 DOI: 10.1002/sim.9217] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2020] [Revised: 09/19/2021] [Accepted: 09/22/2021] [Indexed: 01/01/2023]
Abstract
Hypoplastic left heart syndrome is a congenital anomaly that is uniformly fatal in infancy without immediate treatment. The standard treatment consists of an initial Norwood procedure (stage 1) followed some months later by stage 2 palliation (S2P). The ideal timing of the S2P is uncertain. The Single Ventricle Reconstruction Trial (SVRT) randomized the procedure used in the initial Norwood operation, leaving the timing of the S2P to the discretion of the surgical team. To estimate the causal effect of the timing of S2P, we propose to impute the potential post-S2P survival outcomes using statistical models under the Rubin Causal Model framework. With this approach, it is straightforward to estimate the causal effect of S2P timing on post-S2P survival by directly comparing the imputed potential outcomes. Specifically, we consider a lognormal model and a restricted cubic spline model, evaluating their performance in Monte Carlo studies. When applied to the SVRT data, the models give somewhat different imputed values, but both support the conclusion that the optimal time for the S2P is at 6 months after the Norwood procedure.
Collapse
|
13
|
Myopericarditis after messenger RNA Coronavirus Disease 2019 Vaccination in Adolescents 12 to 18 Years of Age. J Pediatr 2021; 238:26-32.e1. [PMID: 34339728 PMCID: PMC8321962 DOI: 10.1016/j.jpeds.2021.07.044] [Citation(s) in RCA: 47] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Revised: 07/14/2021] [Accepted: 07/16/2021] [Indexed: 01/06/2023]
Abstract
OBJECTIVES To characterize the clinical course and outcomes of children 12-18 years of age who developed probable myopericarditis after vaccination with the Pfizer-BioNTech (BNT162b2) coronavirus disease 2019 (COVID-19) messenger RNA (mRNA) vaccine. STUDY DESIGN A cross-sectional study of 25 children, aged 12-18 years, diagnosed with probable myopericarditis after COVID-19 mRNA vaccination as per the Centers for Disease Control and Prevention criteria for myopericarditis at 8 US centers between May 10, 2021, and June 20, 2021. We retrospectively collected the following data: demographics, severe acute respiratory syndrome coronavirus 2 virus detection or serologic testing, clinical manifestations, laboratory test results, imaging study results, treatment, and time to resolutions of symptoms. RESULTS Most (88%) cases followed the second dose of vaccine, and chest pain (100%) was the most common presenting symptom. Patients came to medical attention a median of 2 days (range, <1-20 days) after receipt of Pfizer mRNA COVID-19 vaccination. All adolescents had an elevated plasma troponin concentration. Echocardiographic abnormalities were infrequent, and 92% showed normal cardiac function at presentation. However, cardiac magnetic resonance imaging, obtained in 16 patients (64%), revealed that 15 (94%) had late gadolinium enhancement consistent with myopericarditis. Most were treated with ibuprofen or an equivalent nonsteroidal anti-inflammatory drug for symptomatic relief. One patient was given a corticosteroid orally after the initial administration of ibuprofen or an nonsteroidal anti-inflammatory drug; 2 patients also received intravenous immune globulin. Symptom resolution was observed within 7 days in all patients. CONCLUSIONS Our data suggest that symptoms owing to myopericarditis after the mRNA COVID-19 vaccination tend to be mild and transient. Approximately two-thirds of patients underwent cardiac magnetic resonance imaging, which revealed evidence of myocardial inflammation despite a lack of echocardiographic abnormalities.
Collapse
|
14
|
Biomechanical Modeling to Inform Pulmonary Valve Replacement in Tetralogy of Fallot Patients After Complete Repair. Can J Cardiol 2021; 37:1798-1807. [PMID: 34216743 PMCID: PMC9810481 DOI: 10.1016/j.cjca.2021.06.018] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2021] [Revised: 06/05/2021] [Accepted: 06/26/2021] [Indexed: 01/07/2023] Open
Abstract
BACKGROUND A biomechanical model of the heart can be used to incorporate multiple data sources (electrocardiography, imaging, invasive hemodynamics). The purpose of this study was to use this approach in a cohort of patients with tetralogy of Fallot after complete repair (rTOF) to assess comparative influences of residual right ventricular outflow tract obstruction (RVOTO) and pulmonary regurgitation on ventricular health. METHODS Twenty patients with rTOF who underwent percutaneous pulmonary valve replacement (PVR) and cardiovascular magnetic resonance imaging were included in this retrospective study. Biomechanical models specific to individual patient and physiology (before and after PVR) were created and used to estimate the RV myocardial contractility. The ability of models to capture post-PVR changes of right ventricular (RV) end-diastolic volume (EDV) and effective flow in the pulmonary artery (Qeff) was also compared with expected values. RESULTS RV contractility before PVR (mean 66 ± 16 kPa, mean ± standard deviation) was increased in patients with rTOF compared with normal RV (38-48 kPa) (P < 0.05). The contractility decreased significantly in all patients after PVR (P < 0.05). Patients with predominantly RVOTO demonstrated greater reduction in contractility (median decrease 35%) after PVR than those with predominant pulmonary regurgitation (median decrease 11%). The model simulated post-PVR decreased EDV for the majority and suggested an increase of Qeff-both in line with published data. CONCLUSIONS This study used a biomechanical model to synthesize multiple clinical inputs and give an insight into RV health. Individualized modeling allows us to predict the RV response to PVR. Initial data suggest that residual RVOTO imposes greater ventricular work than isolated pulmonary regurgitation.
Collapse
|
15
|
Unsupervised Domain Adaptation From Axial to Short-Axis Multi-Slice Cardiac MR Images by Incorporating Pretrained Task Networks. IEEE TRANSACTIONS ON MEDICAL IMAGING 2021; 40:2939-2953. [PMID: 33471750 PMCID: PMC9817008 DOI: 10.1109/tmi.2021.3052972] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Anisotropic multi-slice Cardiac Magnetic Resonance (CMR) Images are conventionally acquired in patient-specific short-axis (SAX) orientation. In specific cardiovascular diseases that affect right ventricular (RV) morphology, acquisitions in standard axial (AX) orientation are preferred by some investigators, due to potential superiority in RV volume measurement for treatment planning. Unfortunately, due to the rare occurrence of these diseases, data in this domain is scarce. Recent research in deep learning-based methods mainly focused on SAX CMR images and they had proven to be very successful. In this work, we show that there is a considerable domain shift between AX and SAX images, and therefore, direct application of existing models yield sub-optimal results on AX samples. We propose a novel unsupervised domain adaptation approach, which uses task-related probabilities in an attention mechanism. Beyond that, cycle consistency is imposed on the learned patient-individual 3D rigid transformation to improve stability when automatically re-sampling the AX images to SAX orientations. The network was trained on 122 registered 3D AX-SAX CMR volume pairs from a multi-centric patient cohort. A mean 3D Dice of 0.86 ± 0.06 for the left ventricle, 0.65 ± 0.08 for the myocardium, and 0.77 ± 0.10 for the right ventricle could be achieved. This is an improvement of 25% in Dice for RV in comparison to direct application on axial slices. To conclude, our pre-trained task module has neither seen CMR images nor labels from the target domain, but is able to segment them after the domain gap is reduced. Code: https://github.com/Cardio-AI/3d-mri-domain-adaptation.
Collapse
|
16
|
Automated Quantitative Stress Perfusion Cardiac Magnetic Resonance in Pediatric Patients. Front Pediatr 2021; 9:699497. [PMID: 34540764 PMCID: PMC8446614 DOI: 10.3389/fped.2021.699497] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/23/2021] [Accepted: 08/05/2021] [Indexed: 11/13/2022] Open
Abstract
Background: Myocardial ischemia occurs in pediatrics, as a result of both congenital and acquired heart diseases, and can lead to further adverse cardiac events if untreated. The aim of this work is to assess the feasibility of fully automated, high resolution, quantitative stress myocardial perfusion cardiac magnetic resonance (CMR) in a cohort of pediatric patients and to evaluate its agreement with the coronary anatomical status of the patients. Methods: Fourteen pediatric patients, with 16 scans, who underwent dual-bolus stress perfusion CMR were retrospectively analyzed. All patients also had anatomical coronary assessment with either CMR, CT, or X-ray angiography. The perfusion CMR images were automatically processed and quantified using an analysis pipeline previously developed in adults. Results: Automated perfusion quantification was successful in 15/16 cases. The coronary perfusion territories supplied by vessels affected by a medium/large aneurysm or stenosis (according to the AHA guidelines), induced by Kawasaki disease, an anomalous origin, or interarterial course had significantly reduced myocardial blood flow (MBF) (median (interquartile range), 1.26 (1.05, 1.67) ml/min/g) as compared to territories supplied by unaffected coronaries [2.57 (2.02, 2.69) ml/min/g, p < 0.001] and territories supplied by vessels with a small aneurysm [2.52 (2.45, 2.83) ml/min/g, p = 0.002]. Conclusion: Automatic CMR-derived MBF quantification is feasible in pediatric patients, and the technology could be potentially used for objective non-invasive assessment of ischemia in children with congenital and acquired heart diseases.
Collapse
|
17
|
Fick versus flow: a real-time invasive cardiovascular magnetic resonance (iCMR) reproducibility study. J Cardiovasc Magn Reson 2021; 23:95. [PMID: 34275477 PMCID: PMC8287667 DOI: 10.1186/s12968-021-00784-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2020] [Accepted: 05/26/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Cardiac catheterization and cardiovascular magnetic resonance (CMR) imaging have distinct diagnostic roles in the congenital heart disease (CHD) population. Invasive CMR (iCMR) allows for a more thorough assessment of cardiac hemodynamics at the same time under the same conditions. It is assumed but not proven that iCMR gives an incremental value by providing more accurate flow quantification. METHODS Subjects with CHD underwent real-time 1.5 T iCMR using a passive catheter tracking technique with partial saturation pulse of 40° to visualize the gadolinium-filled balloon, CMR-conditional guidewire, and cardiac structures simultaneously to aid in completion of right (RHC) and left heart catheterization (LHC). Repeat iCMR and catheterization measurements were performed to compare reliability by the Pearson (PCC) and concordance correlation coefficients (CCC). RESULTS Thirty CHD (20 single ventricle and 10 bi-ventricular) subjects with a median age and weight of 8.3 years (2-33) and 27.7 kg (9.2-80), respectively, successfully underwent iCMR RHC and LHC. No catheter related complications were encountered. Time taken for first pass RHC and LHC/aortic pull back was 5.1, and 2.9 min, respectively. Total success rate to obtain required data points to complete Fick principle calculations for all patients was 321/328 (98%). One patient with multiple shunts was an outlier and excluded from further analysis. The PCC for catheter-derived pulmonary blood flow (Qp) (0.89, p < 0.001) is slightly lower than iCMR-derived Qp (0.96, p < 0.001), whereas catheter-derived systemic blood flow (Qs) (0.62, p = < 0.001) was considerably lower than iCMR-derived Qs (0.94, p < 0.001). CCC agreement for Qp at baseline (C1-CCC = 0.65, 95% CI 0.41-0.81) and retested conditions (C2-CCC = 0.78, 95% CI 0.58-0.89) were better than for Qs at baseline (C1-CCC = 0.22, 95% CI - 0.15-0.53) and retested conditions (C2-CCC = 0.52, 95% CI 0.17-0.76). CONCLUSION This study further validates hemodynamic measurements obtained via iCMR. iCMR-derived flows have considerably higher test-retest reliability for Qs. iCMR evaluations allow for more reproducible hemodynamic assessments in the CHD population.
Collapse
|
18
|
Interventional Cardiovascular Magnetic Resonance Imaging (iCMR) in an Adolescent with Pulmonary Hypertension. MEDICINA (KAUNAS, LITHUANIA) 2020; 56:medicina56120636. [PMID: 33255307 PMCID: PMC7760170 DOI: 10.3390/medicina56120636] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/06/2020] [Revised: 11/11/2020] [Accepted: 11/20/2020] [Indexed: 06/12/2023]
Abstract
The interventional cardiac magnetic resonance imaging (iCMR) catheterization procedure is feasible and safe for children and adults with pulmonary hypertension and congenital heart defects (CHD). With iCMR, the calculation of pulmonary vascular resistance (PVR) in children with complex CHD with multilevel shunt lesions is accurate. In this paper, we describe the role of the MRI-guided right-sided cardiac catheterization procedure to accurately estimate PVR in the setting of multiple shunt lesions (ventricular septal defect and patent ductus arteriosus) and to address the clinical question of operability in an adolescent with trisomy 21 and severe pulmonary hypertension.
Collapse
|
19
|
Estimating the optimal timing of surgery from observational data. Biometrics 2020; 77:729-739. [PMID: 32506431 DOI: 10.1111/biom.13311] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2019] [Revised: 05/29/2020] [Accepted: 06/01/2020] [Indexed: 11/29/2022]
Abstract
Infants with hypoplastic left heart syndrome require an initial Norwood operation, followed some months later by a stage 2 palliation (S2P). The timing of S2P is critical for the operation's success and the infant's survival, but the optimal timing, if one exists, is unknown. We attempt to identify the optimal timing of S2P by analyzing data from the Single Ventricle Reconstruction Trial (SVRT), which randomized patients between two different types of Norwood procedure. In the SVRT, the timing of the S2P was chosen by the medical team; thus with respect to this exposure, the trial constitutes an observational study, and the analysis must adjust for potential confounding. To accomplish this, we propose an extended propensity score analysis that describes the time to surgery as a function of confounders in a discrete competing-risk model. We then apply inverse probability weighting to estimate a spline hazard model for predicting survival from the time of S2P. Our analysis suggests that S2P conducted at 6 months after the Norwood gives the patient the best post-S2P survival. Thus, we place the optimal time slightly later than a previous analysis in the medical literature that did not account for competing risks of death and heart transplantation.
Collapse
|
20
|
Invasive cardiovascular magnetic resonance (iCMR) for diagnostic right and left heart catheterization using an MR-conditional guidewire and passive visualization in congenital heart disease. J Cardiovasc Magn Reson 2020; 22:20. [PMID: 32213193 PMCID: PMC7098096 DOI: 10.1186/s12968-020-0605-9] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2019] [Accepted: 02/05/2020] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND Today's standard of care, in the congenital heart disease (CHD) population, involves performing cardiac catheterization under x-ray fluoroscopy and cardiac magnetic resonance (CMR) imaging separately. The unique ability of CMR to provide real-time functional imaging in multiple views without ionizing radiation exposure has the potential to be a powerful tool for diagnostic and interventional procedures. Limiting fluoroscopic radiation exposure remains a challenge for pediatric interventional cardiologists. This pilot study's objective is to establish feasibility of right (RHC) and left heart catheterization (LHC) during invasive CMR (iCMR) procedures at our institution in the CHD population. Furthermore, we aim to improve simultaneous visualization of the catheter balloon tip, MR-conditional guidewire, and cardiac/vessel anatomy during iCMR procedures. METHODS Subjects with CHD were enrolled in a pilot study for iCMR procedures at 1.5 T with an MR-conditional guidewire. The CMR area is located adjacent to a standard catheterization laboratory. Using the interactive scanning mode for real-time control of the imaging location, a dilute gadolinium-filled balloon-tip catheter was used in combination with an MR-conditional guidewire to obtain cardiac saturations and hemodynamics. A recently developed catheter tracking technique using a real-time single-shot balanced steady-state free precession (bSSFP), flip angle (FA) 35-45°, echo time (TE) 1.3 ms, repetition time (TR) 2.7 ms, 40° partial saturation (pSAT) pre-pulse was used to visualize the gadolinium-filled balloon, MR-conditional guidewire, and cardiac structures simultaneously. MR-conditional guidewire visualization was enabled due to susceptibility artifact created by distal markers. Pre-clinical phantom testing was performed to determine the optimum imaging FA-pSAT combination. RESULTS The iCMR procedure was successfully performed to completion in 31/34 (91%) subjects between August 1st, 2017 to December 13th, 2018. Median age and weight were 7.7 years and 25.2 kg (range: 3 months - 33 years and 8 - 80 kg). Twenty-one subjects had single ventricle (SV) anatomy: one subject was referred for pre-Glenn evaluation, 11 were pre-Fontan evaluations and 9 post-Fontan evaluations for protein losing enteropathy (PLE) and/or cyanosis. Thirteen subjects had bi-ventricular (BiV) anatomy, 4 were referred for coarctation of the aorta (CoA) evaluations, 3 underwent vaso-reactivity testing with inhaled nitric oxide, 3 investigated RV volume dimensions, two underwent branch PA stenosis evaluation, and the remaining subject was status post heart transplant. No catheter related complications were encountered. Average time taken for first pass RHC, LHC/aortic pull back, and to cross the Fontan fenestration was 5.2, 3.0, and 6.5 min, respectively. Total success rate to obtain required data points to complete Fick principle calculations for all patients was 331/337 (98%). Subjects were transferred to the x-ray fluoroscopy lab if further intervention was required including Fontan fenestration device closure, balloon angioplasty of pulmonary arteries/conduits, CoA stenting, and/or coiling of aortopulmonary (AP) collaterals. Starting with subject #10, an MR-conditional guidewire was used in all subsequent subjects (15 SV and 10 BiV) with a success rate of 96% (24/25). Real-time CMR-guided RHC (25/25 subjects, 100%), retrograde and prograde LHC/aortic pull back (24/25 subjects, 96%), CoA crossing (3/4 subjects, 75%) and Fontan fenestration test occlusion (2/3 subjects, 67%) were successfully performed in the majority of subjects when an MR-conditional guidewire was utilized. CONCLUSION Feasibility for detailed diagnostic RHC, LHC, and Fontan fenestration test occlusion iCMR procedures in SV and BiV pediatric subjects with complex CHD is demonstrated with the aid of an MR-conditional guidewire. A novel real-time pSAT GRE sequence with optimized FA-pSAT angle has facilitated simultaneous visualization of the catheter balloon tip, MR-conditional guidewire, and cardiac/vessel anatomy during iCMR procedures.
Collapse
|
21
|
Pulse Wave Velocity Comparing Estimated and Direct Measures of Path Length in Older Women. Artery Res 2020. [DOI: 10.2991/artres.k.200819.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022] Open
|
22
|
Feasibility of real-time cine cardiac magnetic resonance imaging to predict the presence of significant retrosternal adhesions prior to redo-sternotomy. J Cardiovasc Magn Reson 2019; 21:67. [PMID: 31672164 PMCID: PMC6824134 DOI: 10.1186/s12968-019-0576-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2019] [Accepted: 09/21/2019] [Indexed: 11/20/2022] Open
Abstract
BACKGROUND Injury to vital structures posterior to the sternum is a complication associated with redo sternotomy in congenital cardiac surgery. The goal of our study was a novel evaluation of real-time cine cardiovascular magnetic resonance (CMR) to predict the presence of significant retrosternal adhesions of cardiac and vascular structures prior to redo sternotomy in patients with congenital heart disease. METHODS Twenty-three patients who had prior congenital heart surgery via median sternotomy had comprehensive CMR studies prior to redo sternotomy. The real time cine (RTC) sequence that was used is an ungated balanced steady-state free precession (bSSFP) sequence using SENSitivity Encoding for acceleration with real-time reconstruction. Spontaneously breathing patients were instructed to take deep breaths during the acquisition whilst increased tidal volumes were delivered to mechanically ventilated patients. All patients underwent redo cardiac surgery subsequently and the presence and severity of retrosternal adhesions were noted at the time of the redo sternotomies. RESULTS Median age at the time of CMR and operation were 5.5 years (range, 0.2-18.4y) and 6.1 years (range, 0.3-18.8y) respectively. There were 15 males and 8 females in the study group. Preoperative retrosternal adhesions were identified on RTC in 13 patients and confirmed in 11 (85%) at the time of surgery. In only 2 patients, no adhesions were identified on CMR but were found to have significant retrosternal adhesions at surgery; false positive rate 15% (CI 0.4-29.6%), false negative rate 20% (CI 3.7-36.4%). The total classification error of the real time cine sequence was 17% (CI 1.7-32.4%) with an overall accuracy of 83% (CI 67.7-98.4%). Standard breath-hold cine images correlated poorly with surgical findings and did not increase the diagnostic yield. CONCLUSIONS RTC imaging can predict the presence of significant retrosternal adhesions and thus help in risk assessment prior to redo sternotomy. These findings complement the surgical planning and potentially reduce surgical complications .
Collapse
|
23
|
Pediatric heterozygous familial hypercholesterolemia patients have locally increased aortic pulse wave velocity and wall thickness at the aortic root. Int J Cardiovasc Imaging 2019; 35:1903-1911. [PMID: 31209684 DOI: 10.1007/s10554-019-01626-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/31/2019] [Accepted: 05/10/2019] [Indexed: 01/02/2023]
Abstract
Familial hypercholesterolemia (FH) is an autosomal dominant disorder that affects 1 in 250 people. Aortic stiffness, measured by pulse wave velocity (PWV), is an independent predictor for cardiovascular events. Young FH patients are a unique group with early vessel wall disease that may serve to elucidate the determinants of aortic stiffness. We hypothesized that young FH patients would have early changes in aortic stiffness compared to healthy, age- and sex-matched reference values. Thirty-three FH patients ( ≥ 7 years age; mean age 14.6 ± 3.3 years; 26/33 on statin therapy) underwent cardiac MRI. PWV was determined using propagation of flow waveform from aortic arch phase contrast images. Distensibility and aortic wall thickness (AWT) were measured at the ascending, proximal descending, and diaphragmatic aorta. Ventricular volumes and left ventricular (LV) myocardial mass were measured from 2D cine images. These parameters were compared to age- and sex-matched reference values. FH patients had significantly higher PWV (4.5 ± 0.8 vs. 3.5 ± 0.3 m/s; p < 0.001), aortic distensibility, and ascending aortic wall thickness (1.37 ± 0.18 vs. 1.30 ± 0.02 mm; p < 0.05) compared to reference. There was no difference in aortic area or descending aortic wall thickness between groups. Young FH patients had aortic changes with increased aortic pulse wave velocity in the setting of increased aortic distensibility, accompanied by increased thickness of the ascending aortic wall. Presence of these early findings in young patients despite the majority being on statin therapy support enhanced screening and aggressive treatment of familial hypercholesterolemia to prevent potential future cardiovascular events.
Collapse
|
24
|
Creating three dimensional models of the right ventricular outflow tract: influence of contrast, sequence, operator, and threshold. Int J Cardiovasc Imaging 2019; 35:2067-2076. [PMID: 31203535 DOI: 10.1007/s10554-019-01646-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2019] [Accepted: 06/07/2019] [Indexed: 11/29/2022]
Abstract
The use of 3D printed models of the right ventricular outflow tract (RVOT) for surgical and interventional planning is growing and often requires image segmentation of cardiac magnetic resonance (CMR) images. Segmentation results may vary based on contrast, image sequence, signal threshold chosen by the operator, and manual post-processing. The purpose of this study was to determine potential biases and post-processing errors in image segmentation to enable informed decisions. Models of the RVOT and pulmonary arteries from twelve patients who had contrast enhanced CMR angiography with gadopentetate dimeglumine (GPD), gadofosveset trisodium (GFT), and a post-GFT inversion-recovery (IR) whole heart sequence were segmented, trimmed, and aligned by three operators. Geometric agreement and minimal RVOT diameters were compared between sequences and operators. To determine the contribution of threshold, interoperator variability was compared between models created by the same two operators using the same versus different thresholds. Geometric agreement by Dice between objects was high (intraoperator: 0.89-0.95; interoperator: 0.95-0.97), without differences between sequences. Minimal RVOT diameters differed on average by - 1.9 to - 1.3 mm (intraoperator) and by 0.4 to 1.4 mm (interoperator). The contribution of threshold to interoperator geometric agreement was not significant (same threshold: 0.96 ± 0.06, different threshold: 0.93 ± 0.05; p = 0.181), but minimal RVOT diameters were more variable with different versus constant thresholds (- 9.12% vs. 2.42%; p < 0.05). Thresholding does not significantly change interoperator variability for geometric agreement, but does for minimal RVOT diameter. Minimal RVOT diameters showed clinically relevant variation within and between operators.
Collapse
|
25
|
The importance of qualitative and quantitative regional wall motion abnormality assessment at rest in pediatric coronary allograft vasculopathy. Pediatr Transplant 2018; 22:e13208. [PMID: 29733526 DOI: 10.1111/petr.13208] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 03/23/2018] [Indexed: 11/30/2022]
Abstract
CAV remains one of the main limiting factors for survival in children after heart transplantation. In this study, we explored the incremental value of routine CMR for evaluation and detection of CAV using qualitative and quantitative analysis of regional and global myocardial function and strain. This was a prospective imaging biomarker validation trial. Twenty-two patients (11 male), aged between 10 and 17 years (median 14 years) post-heart transplantation, were prospectively enrolled and underwent CMR in addition to their biennial review workup with Echo, angiography, and IVUS. Nine healthy control patients were enrolled to undergo CMR alone. Echo was used to analyze WMAs and systolic function. CMR images were analyzed qualitatively for RWMA and quantitatively for volumetric analysis, S and SR. All results were compared to IVUS and angiography assessments. Qualitatively, CMR detected RWMA corresponding to angiographic disease in 3 patients that were not detected on Echo. However, quantitative strain analysis suggested RWMA in an extra 9 patients. Detection of regional wall motion abnormality using quantitative strain analysis was associated with a higher mean stenosis grade (P=.04) and reduced graft survival (P=.04) compared to those with no quantitative wall motion abnormality. Overall, only longitudinal stain was abnormal in patients compared with controls, but there was no correlation between any of the global indices of S or SR and IVUS measurements. CMR is more sensitive than Echo for the visual detection of significant WMAs. Quantitative CMR strain analysis at rest may give additional information to discriminate those at greatest risk.
Collapse
|
26
|
Three-dimensional printed models for surgical planning of complex congenital heart defects: an international multicentre study. Eur J Cardiothorac Surg 2018; 52:1139-1148. [PMID: 28977423 DOI: 10.1093/ejcts/ezx208] [Citation(s) in RCA: 152] [Impact Index Per Article: 25.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/21/2017] [Accepted: 05/21/2017] [Indexed: 01/10/2023] Open
Abstract
OBJECTIVES To evaluate the impact of 3D printed models (3D models) on surgical planning in complex congenital heart disease (CHD). METHODS A prospective case-crossover study involving 10 international centres and 40 patients with complex CHD (median age 3 years, range 1 month-34 years) was conducted. Magnetic resonance imaging and computed tomography were used to acquire and segment the 3D cardiovascular anatomy. Models were fabricated by fused deposition modelling of polyurethane filament, and dimensions were compared with medical images. Decisions after the evaluation of routine clinical images were compared with those after inspection of the 3D model and intraoperative findings. Subjective satisfaction questionnaire was provided. RESULTS 3D models accurately replicate anatomy with a mean bias of -0.27 ± 0.73 mm. Ninety-six percent of the surgeons agree or strongly agree that 3D models provided better understanding of CHD morphology and improved surgical planning. 3D models changed the surgical decision in 19 of the 40 cases. Consideration of a 3D model refined the planned biventricular repair, achieving an improved surgical correction in 8 cases. In 4 cases initially considered for conservative management or univentricular palliation, inspection of the 3D model enabled successful biventricular repair. CONCLUSIONS 3D models are accurate replicas of the cardiovascular anatomy and improve the understanding of complex CHD. 3D models did not change the surgical decision in most of the cases (21 of 40 cases, 52.5% cases). However, in 19 of the 40 selected complex cases, 3D model helped redefining the surgical approach.
Collapse
|
27
|
Arterial stiffening is a heritable trait associated with arterial dilation but not wall thickening: a longitudinal study in the twins UK cohort. Eur Heart J 2018; 39:2282-2288. [PMID: 29590330 PMCID: PMC6012080 DOI: 10.1093/eurheartj/ehy165] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/05/2017] [Revised: 12/15/2017] [Accepted: 03/07/2018] [Indexed: 01/19/2023] Open
Abstract
Aims Vascular ageing is characterized by arterial stiffening, dilation, and arterial wall thickening. We investigated the extent to which these changes are related and their heritability during 5 year follow-up in the Twins UK cohort. Methods and results Carotid-femoral pulse wave velocity (PWVcf), carotid diameter, carotid distensibility, and carotid intima-media thickness (IMT) were measured in 762 female twins (mean age 57.9 ± 8.6 years) at two time-points over an average follow-up of 4.9 ± 1.5 years. Magnetic resonance imaging (MRI) was performed in a sub-sample of 38 women to measure aortic pulse wave velocity (PWVaorta), diameter, and wall thickness. Heritability of changes in arterial wall properties was estimated using structural equation modelling. Annual increases in PWVcf, carotid diameter, distensibility, and IMT were 0.139 m/s, 0.028 mm, -0.4 kPa-1, and 0.011 mm per year, respectively. In regression analysis, predictors of progression in PWVcf included age, mean arterial pressure (MAP), and heart rate (HR) at baseline, and progression in MAP, HR, and body mass index (BMI). Predictors of progression in IMT included progression in MAP, BMI, and triglyceride levels. Progression of PWV and distensibility correlated with progression in carotid diameter but not with IMT. Heritability of progression of PWVcf, diameter, and IMT was 55%, 21%, and 8%, respectively. In a sub-sample of women that underwent MRI, aortic wall thickness increased by 0.19 mm/year, but aortic wall thickening was not correlated with an increase in lumen diameter or PWVaorta. Conclusion Arterial stiffening, as measured by PWVcf, and dilation are heritable but independent of arterial wall thickening. Genetic and cardiovascular risk factors contribute differently to progression of PWV and IMT.
Collapse
|
28
|
Abstract
Current cardiovascular imaging techniques allow anatomical relationships and pathological conditions to be captured in three dimensions. Three-dimensional (3D) printing, or rapid prototyping, has also become readily available and made it possible to transform virtual reconstructions into physical 3D models. This technology has been utilised to demonstrate cardiovascular anatomy and disease in clinical, research and educational settings. In particular, 3D models have been generated from cardiovascular computed tomography (CT) imaging data for purposes such as surgical planning and teaching. This review summarises applications, limitations and practical steps required to create a 3D printed model from cardiovascular CT.
Collapse
|
29
|
Ventricular function and vascular dimensions after Norwood and hybrid palliation of hypoplastic left heart syndrome. Heart 2017; 104:244-252. [DOI: 10.1136/heartjnl-2017-311532] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/15/2017] [Revised: 05/29/2017] [Accepted: 06/22/2017] [Indexed: 11/04/2022] Open
Abstract
ObjectiveNorwood and hybrid procedure are two options available for initial palliation of patients with hypoplastic left heart syndrome (HLHS). Our study aimed to assess potential differences in right ventricular (RV) function and pulmonary artery dimensions using cardiac magnetic resonance (CMR) in survivors with HLHS.Methods42 Norwood (mean age 2.4±0.8) and 44 hybrid (mean age 2.0±1.0 years) patients were evaluated by CMR after stage II palliation prior to planned Fontan completion. Initial stage I Norwood procedure was performed using a modified Blalock-Taussig shunt, while the hybrid procedure consisted of bilateral pulmonary artery banding and arterial duct stenting. Need for reinterventions and subsequent outcomes were also assessed.ResultsNorwood patients had larger RV end-diastolic dimensions (91±23 vs 80±31 mL/m2, p=0.004) and lower heart rate (90±15 vs 102±13, p<0.001) than hybrid patients. Both Norwood and hybrid patients showed preserved global RV pump function (59±9 vs 59%±10%, p=0.91), while RV strain, strain rate and intraventricular synchrony were superior in the Norwood group. Pulmonary artery size was reduced (lower lobe index 135±74 vs 161±62 mm2/m2, p=0.02), and reintervention rate was significantly higher in the hybrid group whereas subsequent outcome did not differ significantly (p=0.24).ConclusionsNorwood and hybrid strategy were associated with equivalent and preserved global RV pump function while development of the pulmonary arteries and reintervention rate were superior using the Norwood approach. Impaired RV myocardial deformation as a potential marker of early RV dysfunction in the hybrid group may have a negative long-term impact in this population.
Collapse
|
30
|
Abstract
Three-dimensional (3D) whole heart techniques form a cornerstone in cardiovascular magnetic resonance imaging of congenital heart disease (CHD). It offers significant advantages over other CHD imaging modalities and techniques: no ionizing radiation; ability to be run free-breathing; ECG-gated dual-phase imaging for accurate measurements and tissue properties estimation; and higher signal-to-noise ratio and isotropic voxel resolution for multiplanar reformatting assessment. However, there are limitations, such as potentially long acquisition times with image quality degradation. Recent advances in and current applications of 3D whole heart imaging in CHD are detailed, as well as future directions.
Collapse
|
31
|
Abstract
Objective: The objective of this study was to determine whether left ventricular (LV) myocardial deformation indices can detect subclinical abnormalities in Kawasaki disease convalescence. We hypothesized that subclinical myocardial abnormalities due to inflammation represent an early manifestation of the disease that persists in convalescence. Background: Myocardial inflammation has been described as a global finding in the acute phase of Kawasaki disease. Despite normal systolic function by routine functional measurements, reduced longitudinal strain and strain rate have been detected by echocardiography in the acute phase. Methods and Results: Peak systolic LV myocardial longitudinal, radial, and circumferential strain and strain rate were examined in 29 Kawasaki disease convalescent patients (15 males; mean [standard deviation] age: 11 [6.6] years; median interval from disease onset: 5.8 [5.4] years) and 10 healthy volunteers (5 males; mean age: 14 [3.8] years) with the use of cardiac magnetic resonance (CMR) feature tracking. Routine indices of LV systolic function were normal in both groups. Comparisons were made between normal controls and (i) the entire Kawasaki disease group, (ii) Kawasaki disease subgroup divided by coronary artery involvement. Average longitudinal and circumferential strain at all levels was lower in patients compared to normal controls. In subgroup analysis, both Kawasaki disease patients with and without a history of coronary involvement had similar longitudinal and circumferential strain at all levels and lower when compared to controls. There were lower circumferential and longitudinal values in Kawasaki disease patients with persisting coronary artery lesions when compared to those with regressed ones. Conclusion: In this CMR study in Kawasaki disease convalescent patients with preserved routine functional indices, we detected lower circumferential and longitudinal strain values compared to normal controls, irrespective of the coronary artery status.
Collapse
|
32
|
Magnetic resonance imaging planning in children with complex congenital heart disease - A new approach. JRSM Cardiovasc Dis 2017; 6:2048004017701870. [PMID: 28491295 PMCID: PMC5406152 DOI: 10.1177/2048004017701870] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2017] [Accepted: 02/21/2017] [Indexed: 12/02/2022] Open
Abstract
OBJECTIVES To compare a standard sequential 2D Planning Method (2D-PM) with a 3D offline Planning Method (3D-PM) based on 3D contrast-enhanced magnetic resonance angiography (CE-MRA) in children with congenital heart disease (CHD). DESIGN In 14 children with complex CHD (mean: 2.6 years, range: 3 months to 7.6 years), axial and coronal cuts were obtained with single slice spin echo sequences to get the final double oblique longitudinal cut of the targeted anatomical structure (2D-PM, n = 31). On a separate workstation, similar maximal intensity projection (MIP) images were generated offline from a 3D CE-MRA. MIP images were localizers for repeated targeted imaging using the previous spin echo sequence (3D-PM). Finally, image coverage, spatial orientation and acquisition time were compared for 2D-PM and 3D-PM. MAIN OUTCOME MEASURES 2D-PM and 3D-PM images were similar: both perfectly covered the selected anatomic regions and no spatial differences were found (p>0.05). The mean time for creation of the final imaging plane was 241 ± 31 s (2D-PM) compared to 71 ± 18 s (3D-PM) (p<0.05). CONCLUSIONS 3D-PM shows similar results compared to 2D-PM, but allows faster and offline planning thereby reducing the scan time significantly. As newly developed high-resolution 3D datasets can also be used further improvement of this technology is expected.
Collapse
|
33
|
Coronary MR angiography at 3T: fat suppression versus water-fat separation. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2016; 29:733-8. [PMID: 27038934 PMCID: PMC5033991 DOI: 10.1007/s10334-016-0550-7] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/19/2015] [Revised: 03/08/2016] [Accepted: 03/11/2016] [Indexed: 01/17/2023]
Abstract
Objectives To compare Dixon water-fat suppression with spectral pre-saturation with inversion recovery (SPIR) at 3T for coronary magnetic resonance angiography (MRA) and to demonstrate the feasibility of fat suppressed coronary MRA at 3T without administration of a contrast agent. Materials and methods Coronary MRA with Dixon water-fat separation or with SPIR fat suppression was compared on a 3T scanner equipped with a 32-channel cardiac receiver coil. Eight healthy volunteers were examined. Contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), right coronary artery (RCA), and left anterior descending (LAD) coronary artery sharpness and length were measured and statistically compared. Two experienced cardiologists graded the visual image quality of reformatted Dixon and SPIR images (1: poor quality to 5: excellent quality). Results Coronary MRA images in healthy volunteers showed improved contrast with the Dixon technique compared to SPIR (CNR blood-fat: Dixon = 14.9 ± 2.9 and SPIR = 13.9 ± 2.1; p = 0.08, CNR blood-myocardium: Dixon = 10.2 ± 2.7 and SPIR = 9.11 ± 2.6; p = 0.1). The Dixon method led to similar fat suppression (fat SNR with Dixon: 2.1 ± 0.5 vs. SPIR: 2.4 ± 1.2, p = 0.3), but resulted in significantly increased SNR of blood (blood SNR with Dixon: 19.9 ± 4.5 vs. SPIR: 15.5 ± 3.1, p < 0.05). This means the residual fat signal is slightly lower with the Dixon compared to the SIPR technique (although not significant), while the SNR of blood is significantly higher with the Dixon technique. Vessel sharpness of the RCA was similar for Dixon and SPIR (57 ± 7 % vs. 56 ± 9 %, p = 0.2), while the RCA visualized vessel length was increased compared to SPIR fat suppression (107 ± 21 vs. 101 ± 21 mm, p < 0.001). For the LAD, vessel sharpness (50 ± 13 % vs. 50 ± 7 %, p = 0.4) and vessel length (92 ± 46 vs. 90 ± 47 mm, p = 0.4) were similar with both techniques. Consequently, the Dixon technique resulted in an improved visual score of the coronary arteries in the water fat separated images of healthy subjects (RCA: 4.6 ± 0.5 vs. 4.1 ± 0.7, p = 0.01, LAD: 4.1 ± 0.7 vs. 3.5 ± 0.8, p = 0.007). Conclusions Dixon water-fat separation can significantly improve coronary artery image quality without the use of a contrast agent at 3T.
Collapse
|
34
|
Cardiac Magnetic Resonance Assessment of Ventricular and Vascular Properties after Stage 2 Palliation for Hypoplastic Left Heart Syndrome: A Dual Center Study Comparing the Norwood and Hybrid Approach. Thorac Cardiovasc Surg 2016. [DOI: 10.1055/s-0036-1571863] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
35
|
Automatic T2* determination for quantification of iron load in heart and liver: a comparison between automatic inline Maximum Likelihood Estimate and the truncation and offset methods. Clin Physiol Funct Imaging 2015; 37:299-304. [PMID: 26475530 DOI: 10.1111/cpf.12303] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2015] [Accepted: 08/03/2015] [Indexed: 11/28/2022]
Abstract
PURPOSE To validate ironload T2* by automatic inline Maximum Likelihood Estimate (MLE) with k-space Rician noise correction, against the manual and automated truncation, as well as offset methods, in phantoms and in heart and liver in patients. METHODS Twenty-five patients and an iron-oxide phantom were scanned at 1.5T using 2 multi-echo gradient-echo sequences. All parameters were identical (voxel 2-3 × 2-3 × 10 mm3 , 10 echoes, TR = 26 ms, FA = 20°, BW = 833 Hz, SENSE = 2) except for TE (cardiac: TE1 = 2·5 ms, ΔTE = 2·5 ms; liver: TE1 = 1·2 ms, ΔTE = 1·5 ms). Phantoms were scanned at 1 and 32 signal averages (NSA), with NSA32 representing low-noise reference. RESULTS Phantoms: MLE showed low variability between NSA1 and NSA32 (0·02 ± 0·29 ms, CI ±0·21 ms). Between methods, no difference was shown (MLE versus all: <0·31 ms, CI < ±0·35 ms). PATIENTS No differences were found between methods in heart (MLE versus all: <-0·22 ms, CI < ±0·75 ms) or liver (MLE versus all: <0·12 ms, CI < ±0·26 ms). CONCLUSIONS The automatic inline MLE method is comparable to the general reference standards for determining cardiac and liver T2* for ironload in man. An automatic inline method may simplify ironload assessment, particularly in centres seeing fewer cases.
Collapse
|
36
|
094 Dobutamine stress MR in tetralogy of fallot with significant pulmonary regurgitation: safety, feasibility and haemodynamic effects. Heart 2015. [DOI: 10.1136/hrt.2010.196071.16] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
37
|
Magnetic resonance imaging catheter stress haemodynamics post-Fontan in hypoplastic left heart syndrome. Eur Heart J Cardiovasc Imaging 2015; 17:644-51. [PMID: 26188193 DOI: 10.1093/ehjci/jev178] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/24/2015] [Accepted: 06/18/2015] [Indexed: 11/13/2022] Open
Abstract
AIMS Exercise limitation is common post-Fontan. Hybrid X-ray and magnetic resonance imaging (XMR) catheterization allows haemodynamic assessment by means of measurement of ventricular volumes and flow in major vessels with simultaneous invasive pressures. We aim to assess haemodynamic response to stress in patients with hypoplastic left heart syndrome (HLHS) post-Fontan. METHODS AND RESULTS Prospective study of 13 symptomatic children (NHYA 2) with HLHS post-Fontan using XMR catheterization. Three conditions were applied: baseline (Stage 1), dobutamine at 10 µg/kg/min (Stage 2), and dobutamine at 20 µg/kg/min (Stage 3). Seven consecutive patients received inhaled nitric oxide (iNO) at peak stress. Control MRI data were from normal healthy adults. In the HLHS patients, baseline mean pulmonary vascular resistance (PVR) was 1.51 ± 0.59 WU m(2) and aortopulmonary collateral flow was 17.7 ± 13.6% of systemic cardiac output. Mean right ventricular end-diastolic pressure was 6.7 ± 2.5 mmHg which did not rise with stress. Cardiac index (CI) increased at Stage 2 in HLHS (40%) and controls (61%) but continued to increase at Stage 3 only in controls (19%) but not in HLHS. The blunted rise in CI in HLHS was due to a continuing fall in end-diastolic volume throughout stress, with no significant change in PVR or CI at peak stress in response to iNO. CONCLUSION Cardiac output post-Fontan in HLHS at peak stress is blunted due to a limitation in preload which is not responsive to inhaled pulmonary vasodilators in the setting of normal PVR.
Collapse
|
38
|
Validation of a new T2* algorithm and its uncertainty value for cardiac and liver iron load determination from MRI magnitude images. Magn Reson Med 2015; 75:1717-29. [PMID: 26010550 PMCID: PMC4791092 DOI: 10.1002/mrm.25767] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2014] [Revised: 03/26/2015] [Accepted: 04/16/2015] [Indexed: 12/24/2022]
Abstract
Purpose To validate an automatic algorithm for offline T2* measurements, providing robust, vendor‐independent T2*, and uncertainty estimates for iron load quantification in the heart and liver using clinically available imaging sequences. Methods A T2* region of interest (ROI)‐based algorithm was developed for robustness in an offline setting. Phantom imaging was performed on a 1.5 Tesla system, with clinically available multiecho gradient‐recalled‐echo (GRE) sequences for cardiac and liver imaging. A T2* single‐echo GRE sequence was used as reference. Simulations were performed to assess accuracy and precision from 2000 measurements. Inter‐ and intraobserver variability was obtained in a patient study (n = 23). Results Simulations: Accuracy, in terms of the mean differences between the proposed method and true T2* ranged from 0–0.73 ms. Precision, in terms of confidence intervals of repeated measurements, was 0.06–4.74 ms showing agreement between the proposed uncertainty estimate and simulations. Phantom study: Bias and variability were 0.26 ± 4.23 ms (cardiac sequence) and −0.23 ± 1.69 ms (liver sequence). Patient study: Intraobserver variability was similar for experienced and inexperienced observers (0.03 ± 1.44 ms versus 0.16 ± 2.33 ms). Interobserver variability was 1.0 ± 3.77 ms for the heart and −0.52 ± 2.75 ms for the liver. Conclusion The proposed algorithm was shown to provide robust T2* measurements and uncertainty estimates over the range of clinically relevant T2* values. Magn Reson Med, 2015. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. Magn Reson Med 75:1717–1729, 2016. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance.
Collapse
|
39
|
Thoracic but not abdominal phase contrast magnetic resonance-derived aortic pulse wave velocity is elevated in patients with abdominal aortic aneurysm. J Hypertens 2015; 33:1032-8. [DOI: 10.1097/hjh.0000000000000516] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
|
40
|
Cardiovascular magnetic resonance catheterization derived pulmonary vascular resistance and medium-term outcomes in congenital heart disease. J Cardiovasc Magn Reson 2015; 17:28. [PMID: 25890289 PMCID: PMC4395971 DOI: 10.1186/s12968-015-0130-4] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2014] [Accepted: 03/13/2015] [Indexed: 11/12/2022] Open
Abstract
BACKGROUND Selection of patients with congenital heart disease for surgical septation in biventricular repair or surgical palliation in functionally single ventricles requires low pulmonary vascular resistance (PVR). Where there is uncertainty, PVR can be assessed using hybrid cardiovascular magnetic resonance (CMR) and fluoroscopic (X-Ray) guided cardiac catheterizations (XMR). CMR/XMR catheterization is a validated technique for accurate assessment of pulmonary vascular resistance. However, data concerning its application in clinical practice is lacking. METHODS PVR assessments were performed in 167 studies in 149 congenital heart disease patients by CMR/XMR catheterization. Data was collated on patient demographics, procedural data, complications and outcomes. Institutional ethics approval was obtained. RESULTS Median age was 3.6 years (6 days-67 years) and weight 13.8 kg (2.3-122 kg). One hundred and eight studies were in biventricular circulations and 59 in functionally single ventricles. Median radiation dose was 0.72 mSv. A baseline Qp:Qs ≤2.75 in biventricular circulations with left-to-right shunts predicted a PVR ≥6 WU x m(2) with 100% sensitivity and 48% specificity. Median follow up until death or last review was 4.2 years (4 days-11 years). Eighty-four patients had a surgical or catheter intervention based on CMR/XMR catheterization findings at a median of 94 days after the study. This included successful biventricular repair at resting PVR values ≤6 WU x m(2) and Fontan completion at ≤4 WU x m(2). CONCLUSION PVR measured by CMR/XMR catheterization allows accurate stratification for intervention in patients with congenital heart disease in both, biventricular and univentricular circulations.
Collapse
|
41
|
Strain Analysis and Wall Motion Abnormalities Detection By Cardiac Magnetic Resonance: Utility in the Diagnosis of Coronary Allograft Vasculopathy. J Heart Lung Transplant 2015. [DOI: 10.1016/j.healun.2015.01.908] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022] Open
|
42
|
Whole left ventricular functional assessment from two minutes free breathing multi-slice CINE acquisition. Phys Med Biol 2015; 60:N93-107. [PMID: 25768044 DOI: 10.1088/0031-9155/60/7/n93] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
Two major challenges in cardiovascular MRI are long scan times due to slow MR acquisition and motion artefacts due to respiratory motion. Recently, a Motion Corrected-Compressed Sensing (MC-CS) technique has been proposed for free breathing 2D dynamic cardiac MRI that addresses these challenges by simultaneously accelerating MR acquisition and correcting for any arbitrary motion in a compressed sensing reconstruction. In this work, the MC-CS framework is combined with parallel imaging for further acceleration, and is termed Motion Corrected Sparse SENSE (MC-SS). Validation of the MC-SS framework is demonstrated in eight volunteers and three patients for left ventricular functional assessment and results are compared with the breath-hold acquisitions as reference. A non-significant difference (P > 0.05) was observed in the volumetric functional measurements (end diastolic volume, end systolic volume, ejection fraction) and myocardial border sharpness values obtained with the proposed and gold standard methods. The proposed method achieves whole heart multi-slice coverage in 2 min under free breathing acquisition eliminating the time needed between breath-holds for instructions and recovery. This results in two-fold speed up of the total acquisition time in comparison to the breath-hold acquisition.
Collapse
|
43
|
Technical and anatomical factors affecting the size of the branch pulmonary arteries following first-stage Norwood palliation for hypoplastic left heart syndrome. Interact Cardiovasc Thorac Surg 2015; 20:631-5. [DOI: 10.1093/icvts/ivv002] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2014] [Accepted: 12/29/2014] [Indexed: 11/12/2022] Open
|
44
|
Juxtaposed right atrial appendage in complex Transposition of the Great Arteries. Rev Port Cardiol 2015; 34:79-80. [DOI: 10.1016/j.repc.2014.08.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2014] [Accepted: 08/16/2014] [Indexed: 10/24/2022] Open
|
45
|
Juxtaposed right atrial appendage in complex Transposition of the Great Arteries. REVISTA PORTUGUESA DE CARDIOLOGIA (ENGLISH EDITION) 2015. [DOI: 10.1016/j.repce.2014.08.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
|
46
|
Diagnosis and management of coronary allograft vasculopathy in children and adolescents. World J Transplant 2014; 4:276-293. [PMID: 25540736 PMCID: PMC4274597 DOI: 10.5500/wjt.v4.i4.276] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/09/2014] [Revised: 08/12/2014] [Accepted: 09/17/2014] [Indexed: 02/05/2023] Open
Abstract
Coronary allograft vasculopathy remains one of the leading causes of death beyond the first year post transplant. As a result of denervation following transplantation, patients lack ischaemic symptoms and presentation is often late when the graft is already compromised. Current diagnostic tools are rather invasive, or in case of angiography, significantly lack sensitivity. Therefore a non-invasive tool that could allow early diagnosis would be invaluable.This paper review the disease form its different diagnosis techniques,including new and less invasive diagnostic tools to its pharmacological management and possible treatments.
Collapse
|
47
|
Coronary vessel wall contrast enhancement imaging as a potential direct marker of coronary involvement: integration of findings from CAD and SLE patients. JACC Cardiovasc Imaging 2014; 7:762-70. [PMID: 25051945 PMCID: PMC4136741 DOI: 10.1016/j.jcmg.2014.03.012] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2013] [Revised: 02/10/2014] [Accepted: 03/10/2014] [Indexed: 01/24/2023]
Abstract
Objectives This study investigated the feasibility of visual and quantitative assessment of coronary vessel wall contrast enhancement (CE) for detection of symptomatic atherosclerotic coronary artery disease (CAD) and subclinical coronary vasculitis in autoimmune inflammatory disease (systemic lupus erythematosus [SLE]), as well as the association with aortic stiffness, an established marker of risk. Background Coronary CE by cardiac magnetic resonance (CMR) is a novel noninvasive approach to visualize gadolinium contrast uptake within the coronary artery vessel wall. Methods A total of 75 subjects (CAD: n = 25; SLE: n = 27; control: n = 23) underwent CMR imaging using a 3-T clinical scanner. Coronary arteries were visualized by a T2-prepared steady state free precession technique. Coronary wall CE was visualized using inversion-recovery T1 weighted gradient echo sequence 40 min after administration of 0.2 mmol/kg gadobutrol. Proximal coronary segments were visually examined for distribution of CE and quantified for contrast-to-noise ratio (CNR) and total CE area. Results Coronary CE was prevalent in patients (93%, n = 42) with a diffuse pattern for SLE and a patchy/regional distribution in CAD patients. Compared with control subjects, CNR values and total CE area in patients with CAD and SLE were significantly higher (mean CNR: 3.9 ± 2.5 vs. 6.9 ± 2.5 vs. 6.8 ± 2.0, respectively; p < 0.001; total CE area: median 0.8 [interquartile range (IQR): 0.6 to 1.2] vs. 3.2 [IQR: 2.6 to 4.0] vs. 3.3 [IQR: 1.9 to 4.5], respectively; p < 0.001). Both measures were positively associated with aortic stiffness (CNR: r = 0.61, p < 0.01; total CE area: 0.36, p = 0.03), hypercholesterolemia (r = 0.68, p < 0.001; r = 0.61, p < 0.001) and hypertension (r = 0.40, p < 0.01; r = 0.32, p < 0.05). Conclusions We demonstrate that quantification of coronary CE by CNR and total CE area is feasible for detection of subclinical and clinical uptake of gadolinium within the coronary vessel wall. Coronary vessel wall CE may become an instrumental novel direct marker of vessel wall injury and remodeling in subpopulations at risk.
Collapse
|
48
|
Highly efficient respiratory motion compensated free-breathing coronary MRA using golden-step Cartesian acquisition. J Magn Reson Imaging 2014; 41:738-46. [PMID: 24573992 DOI: 10.1002/jmri.24602] [Citation(s) in RCA: 102] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2013] [Accepted: 01/31/2014] [Indexed: 11/05/2022] Open
Abstract
PURPOSE To develop an efficient 3D affine respiratory motion compensation framework for Cartesian whole-heart coronary magnetic resonance angiography (MRA). MATERIALS AND METHODS The proposed method achieves 100% scan efficiency by estimating the affine respiratory motion from the data itself and correcting the acquired data in the reconstruction process. For this, a golden-step Cartesian sampling with spiral profile ordering was performed to enable reconstruction of respiratory resolved images at any breathing position and with different respiratory window size. Affine motion parameters were estimated from image-based registration of 3D undersampled respiratory resolved images reconstructed with iterative SENSE and motion correction was performed directly in the reconstruction using a multiple-coils generalized matrix formulation method. This approach was tested on healthy volunteers and compared against a conventional diaphragmatic navigator-gated acquisition using quantitative and qualitative image quality assessment. RESULTS The proposed approach achieved 47 ± 12% and 59 ± 6% vessel sharpness for the right (RCA) and left (LAD) coronary arteries, respectively. Also, good quality visual scores of 2.4 ± 0.74 and 2.44 ± 0.86 were observed for the RCA and LAD (scores from 0, no to 4, excellent coronary vessel delineation). A not statically significant difference (P = 0.05) was found between the proposed method and an 8-mm navigator-gated and tracked scan, although scan efficiency increased from 61 ± 10% to 100%. CONCLUSION We demonstrate the feasibility of a new 3D affine respiratory motion correction technique for Cartesian whole-heart CMRA that achieves 100% scan efficiency and therefore a predictable acquisition time. This approach yields image quality comparable to that of an 8-mm navigator-gated acquisition with lower scan efficiency. Further evaluation of this technique in patients is now warranted to determine its clinical use.
Collapse
|
49
|
Poster session Wednesday 11 December all day display: 11/12/2013, 09:30-16:00 * Location: Poster area. Eur Heart J Cardiovasc Imaging 2013. [DOI: 10.1093/ehjci/jet202] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
50
|
Assessment of cardiac volumes using an isotropic whole-heart dual cardiac phase sequence in pediatric patients. J Magn Reson Imaging 2013; 39:708-16. [PMID: 23723135 DOI: 10.1002/jmri.24203] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2012] [Accepted: 04/12/2013] [Indexed: 11/11/2022] Open
Abstract
PURPOSE To evaluate the accuracy of a three-dimensional dual phase (3D DP) whole-heart technique for cardiac volumetric assessment in pediatric patients with cardiac abnormalities. MATERIALS AND METHODS The institutional approved this study, and informed consent was obtained from patients or their guardians. This prospective study involved 31 pediatric patients (mean age, 7.9 years; range, 15 days to 15 years) for the assessment of cardiac abnormalities using cardiovascular MR. A standard protocol was performed for assessing cardiac anatomy and function. For evaluating the 3D DP technique, statistical comparison with a 2D cine multi-slice technique (2D steady-state free-precession [SSFP]) was performed using linear regression, intraclass correlation coefficient, and Bland Altman plots. RESULTS Left (LV) and right (RV) ventricular cardiac volumes obtained with the 3D DP technique were in strong agreement with those obtained with the 2D SSFP technique for small and large ventricular volumes. The intraclass correlation coefficients (ICC) between both techniques were 0.992 for the LV end-diastolic volume (EDV), 0.983 for the LV end-systolic volume (ESV), 0.952 for the LV-systolic volume (SV), 0.992 for the RV-EDV, 0.992 for the RV-ESV, 0.928 for the RV-SV. Interobserver analysis indicated good reproducibility for both the 2D SSFP and the 3D DP techniques. CONCLUSION The 3D DP technique provides as accurate cardiac volumes as the 2D SSFP technique in the pediatric population, but with the added benefits of easier data acquisition and detailed anatomical information of the whole heart and great vessels in a single free-breathing scan.
Collapse
|