1
|
Clinical variables associated with late-onset thrombotic and cardiovascular events, after SARS-CoV-2 infection, in a cohort of patients from the first epidemic wave: an 18-month analysis on the "Surviving-COVID" cohort from Bergamo, Italy. Front Cardiovasc Med 2023; 10:1280584. [PMID: 38099229 PMCID: PMC10720075 DOI: 10.3389/fcvm.2023.1280584] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2023] [Accepted: 11/08/2023] [Indexed: 12/17/2023] Open
Abstract
Importance Population studies have recorded an increased, unexplained risk of post-acute cardiovascular and thrombotic events, up to 1 year after acute severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. Objectives To search for clinical variables and biomarkers associated with late post-acute thrombotic and cardiovascular events after SARS-CoV-2 infection. Design Retrospective cohort study. Setting Third-level referral hospital in Bergamo (Italy). Participants Analysis of an existing database of adult patients, who received care for SARS-CoV-2 infection at our institution between 20 February and 30 September 2020, followed up on a single date ("entry date") at 3-6 months. Exposure Initial infection by SARS-CoV-2. Main outcomes and measures Primary outcome: occurrence, in the 18 months after entry date, of a composite endpoint, defined by the International Classification of Diseases-9th edition (ICD-9) codes for at least one of: cerebral/cardiac ischemia, venous/arterial thrombosis (any site), pulmonary embolism, cardiac arrhythmia, heart failure. Measures (as recorded on entry date): history of initial infection, symptoms, current medications, pulmonary function test, blood tests results, and semi-quantitative radiographic lung damage (BRIXIA score). Individual clinical data were matched to hospitalizations, voluntary vaccination against SARS-CoV-2 (according to regulations and product availability), and documented reinfections in the following 18 months, as recorded in the provincial Health Authority database. A multivariable Cox proportional hazard model (including vaccine doses as a time-dependent variable) was fitted, adjusting for potential confounders. We report associations as hazard ratios (HR) and 95% confidence intervals (CI). Results Among 1,515 patients (948 men, 62.6%, median age 59; interquartile range: 50-69), we identified 84 endpoint events, occurring to 75 patients (5%): 30 arterial thromboses, 11 venous thromboses, 28 arrhythmic and 24 heart failure events. From a multivariable Cox model, we found the following significant associations with the outcome: previous occurrence of any outcome event, in the 18 months before infection (HR: 2.38; 95% CI: 1.23-4.62); BRIXIA score ≥ 3 (HR: 2.43; 95% CI: 1.30-4.55); neutrophils-to-lymphocytes ratio ≥ 3.3 (HR: 2.60; 95% CI: 1.43-4.72), and estimated glomerular filtration rate < 45 ml/min/1.73 m2 (HR: 3.84; 95% CI: 1.49-9.91). Conclusions and relevance We identified four clinical variables, associated with the occurrence of post-acute thrombotic and cardiovascular events, after SARS-CoV-2 infection. Further research is needed, to confirm these results.
Collapse
|
2
|
Sensory Modulation Abilities in Healthy Preterm-Born Children: An Observational Study Using the Sensory Processing and Self-Regulation Checklist (SPSRC). Biomedicines 2023; 11:2319. [PMID: 37626814 PMCID: PMC10452458 DOI: 10.3390/biomedicines11082319] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 08/03/2023] [Accepted: 08/15/2023] [Indexed: 08/27/2023] Open
Abstract
This study aimed to investigate prematurity as a risk factor for sensory processing disorders, using the Italian Version of Sensory Processing and Self-Regulation Checklist (SPSRC-IT), based on a sample of healthy Italian children born preterm in comparison with a sample of typical full-term children. Two groups of caregivers of Italian healthy preschooler children were recruited. The first group comprised 37 caregivers of full-term children (FT), while the second group consisted of 37 caregivers of preterm children (PT) (gestational age < 37 weeks). Significant differences between the groups in several subsections and factors of the SPSRC-IT were found, specifically in the Physiological Conditions section, in the Gustatory and Olfactory Sense section, in the Vestibular Sense section, and in the Proprioceptive Sense section, with lower scores in the PT group. Moreover, children born at a lower gestational age or with lower weights had a higher risk of dysfunctions in processing gustatory and olfactory, vestibular, and proprioceptive stimuli. In conclusion, the SPSRC-IT suggested a potential link between prematurity and challenges in the development of sensory processing and self-regulation skills, especially in children with a very low birth weight and very low gestational age.
Collapse
|
3
|
Psychometric Properties of the Italian Version of Sensory Processing and Self-Regulation Checklist (SPSRC). Healthcare (Basel) 2022; 11:healthcare11010092. [PMID: 36611551 PMCID: PMC9818758 DOI: 10.3390/healthcare11010092] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 12/15/2022] [Accepted: 12/23/2022] [Indexed: 12/29/2022] Open
Abstract
Sensory processing abilities play important roles in child learning, behavioural and emotional regulation, and motor development. Moreover, it was widely demonstrated that numerous children with neurodevelopmental disabilities show differences in sensory processing abilities and self-regulation compared with those of typical children. For these reasons, a complete evaluation of early symptoms is very important, and specific tools are necessary to better understand and recognize these difficulties during childhood. The main aim of this study was to translate, culturally adapt, and validate in a population of Italian typically developing (TD) children the Sensory Processing and Self-Regulation Checklist (SPSRC), a 130-item caregiver-reported checklist, covering children's sensory processing and self-regulation performance in daily life. Preliminary testing of the SPSRC-IT was carried out in a sample of 312 TD children and 30 children with various developmental disabilities. The findings showed that the SPSRC-IT had high internal consistency, a good discriminant, and structural and criterion validity about the sensory processing and self-regulation abilities of children with and without disabilities. These data provide initial evidence on the reliability and validity of SPSRC-IT, and the information obtained by using the SPSRC-IT may be considered a starting point to widen the current understanding of sensory processing difficulties among children.
Collapse
|
4
|
Comparison of current methods for
anti‐dsDNA
antibody detection and reshaping diagnostic strategies. Scand J Immunol 2022; 96:e13220. [DOI: 10.1111/sji.13220] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2022] [Revised: 09/03/2022] [Accepted: 09/26/2022] [Indexed: 11/29/2022]
|
5
|
Clinical utility of circulating calprotectin to assist prediction and monitoring of COVID-19 severity: An Italian study. J Med Virol 2022; 94:5758-5765. [PMID: 35941084 PMCID: PMC9538954 DOI: 10.1002/jmv.28056] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2022] [Revised: 07/23/2022] [Accepted: 08/05/2022] [Indexed: 01/06/2023]
Abstract
BACKGROUND Calprotectin (S100A8/A9) has been identified as a biomarker that can aid in predicting the severity of disease in COVID-19 patients. This study aims to evaluate the correlation between levels of circulating calprotectin (cCP) and the severity of COVID-19. METHODS Sera from 245 COVID-19 patients and 110 apparently healthy individuals were tested for calprotectin levels using a chemiluminescent immunoassay (Inova Diagnostics). Intensive care unit (ICU) admission and type of respiratory support administered were used as indicators of disease severity, and their correlation with calprotectin levels was assessed. RESULTS Samples from patients in the ICU had a median calprotectin concentration of 11.6 µg/ml as compared to 3.5 µg/ml from COVID-19 patients who were not in the ICU. The median calprotectin concentration in a cohort of healthy individuals collected before the COVID-19 pandemic was 3.0 µg/ml (95% CI: 2.820-2.969 µg/ml). Patients requiring a Venturi mask, continuous positive airway pressure, or orotracheal intubation all had significantly higher values of calprotectin than controls, with the increase of cCP levels proportional to the increasing need of respiratory support. CONCLUSION Calprotectin levels in serum correlate well with disease severity and represent a promising serological biomarker for the risk assessment of COVID-19 patients.
Collapse
|
6
|
Current technologies for anti-ENA antibody detection: State-of-the-art of diagnostic immunoassays. J Immunol Methods 2022; 507:113297. [PMID: 35690095 DOI: 10.1016/j.jim.2022.113297] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2021] [Revised: 06/03/2022] [Accepted: 06/03/2022] [Indexed: 11/19/2022]
Abstract
BACKGROUND Autoantibodies against extractable nuclear antigens (ENA) play a pivotal role in the diagnosis and classification of systemic autoimmune rheumatic diseases (SARD). In recent years, newly developed methods have enabled the simultaneous and quantitative detection of multiple anti-ENA reactivities. However, data regarding the comparability of results obtained using different technologies across different platforms are scarce. In this study we compared eight different immunoassays, commonly used in current laboratory practice for detection of anti-ENA antibodies. METHODS Sixty patients suffering from different SARD, 10 inflammatory arthritis patients (disease controls) and 10 healthy blood donors were included in this comparative study. Sera were collected in 15 centers belonging to the Study Group on Autoimmune Diseases of the Italian Society of Clinical Pathology and Laboratory Medicine. We evaluated the analytical sensitivity, specificity and diagnostic accuracy of each method for antibodies to Sm, RNP, Ro60, Ro52, Scl70, CENP-B and Jo1. Cohen's kappa was used to analyze the agreement among methods. RESULTS Average agreement among methods was 0.82, ranging from substantial (k = 0.72) to almost perfect (k = 0.92). However, while the specificity was very good for all methods, some differences emerged regarding the analytical sensitivity. CONCLUSIONS Diagnostic performance of current technologies for anti-ENA antibody detection showed good comparability. However, as some differences exist among methods, laboratory scientists and clinicians must be aware of the diagnostic accuracy of the testing method in use.
Collapse
|
7
|
T236 Alterations of the complete blood count in natalizumab-treated patients with multiple sclerosis. Clin Chim Acta 2022. [DOI: 10.1016/j.cca.2022.04.724] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
8
|
W037 Is it time to abandon timed collection urine for random urine samples? Clin Chim Acta 2022. [DOI: 10.1016/j.cca.2022.04.168] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
9
|
T205 Clinical study of Aptiva anti-transglutaminase IgA reagent on patients with biopsy results. Clin Chim Acta 2022. [DOI: 10.1016/j.cca.2022.04.689] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
10
|
T207 Anti transglutaminase antibodies could predict the development of celiac disease 5 years before the diagnosis. Clin Chim Acta 2022. [DOI: 10.1016/j.cca.2022.04.691] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
11
|
Bullous Pemphigoid Associated With COVID-19 Vaccines: An Italian Multicentre Study. Front Med (Lausanne) 2022; 9:841506. [PMID: 35295599 PMCID: PMC8918943 DOI: 10.3389/fmed.2022.841506] [Citation(s) in RCA: 29] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Accepted: 02/03/2022] [Indexed: 01/06/2023] Open
Abstract
Bullous pemphigoid (BP) is an autoimmune bullous disease caused by circulating autoantibodies toward the hemidesmosomal antigens BP180 and BP230. Cases of BP have been described following vaccinations against tetanus, poliomyelitis, diphtheria, influenza, pneumococcus, meningococcus, hepatitis B and rabies. The putative mechanism by which COVID-19-vaccines may induce BP has not been clarified. An Italian multicentre study was conducted to collect clinical, histopathological and immunopathological data of patients with BP associated with COVID-19-vaccines. Twenty-one cases were collected, including 9 females and 12 males (M/F = 1.3) with a median age at diagnosis of 82 years. Seventeen patients received the COMIRNATY Pfizer-BioNTech vaccine, two the Moderna mRNA-1273 vaccine, one the ChAdOx1/nCoV-19-AstraZeneca/ Vaxzevria vaccine and one received the first dose with the ChAdOx1/nCoV-19-AstraZeneca/Vaxzevria vaccine and the second dose with the COMIRNATY Pfizer-BioNTech vaccine. Median latency time between the first dose of anti-SARS-CoV-2 vaccine and the onset of cutaneous manifestations was 27 days. Median BPDAI at onset was 42. Eleven out of seventeen patients (65%) had positive titres for anti-BP180 antibodies with a median value of 106.3 U/mL on ELISA; in contrast, only five out of seventeen (29%) were positive for anti-BP230 antibodies, with a median of 35.3 U/mL. In conclusion, in terms of mean age, disease severity at diagnosis and clinical phenotype vaccine-associated BP patients seem to be similar to idiopathic BP with an overall benign course with appropriate treatment. On the other hand, the slight male predominance and the reduced humoral response to BP230 represent peculiar features of this subset of patients.
Collapse
|
12
|
Performance evaluation of automated cell counts compared with reference methods for body fluid analysis. Diagnosis (Berl) 2021; 9:369-378. [PMID: 34599561 DOI: 10.1515/dx-2021-0088] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2021] [Accepted: 09/10/2021] [Indexed: 11/15/2022]
Abstract
OBJECTIVES Cellular analysis of body fluids (BFs) can assist clinicians for the diagnosis of many medical conditions. The aim of this work is the evaluation of the analytical performance of the UF-5000 body fluid mode (UF-BF) analyzer compared to the gold standard method (optical microscopy, OM) and to XN-1000 (XN-BF), another analyzer produced by the same manufacturer (Sysmex) and with a similar technology for BF analysis. METHODS One hundred BF samples collected in K3EDTA tubes were analyzed by UF-BF, XN-BF and OM. The agreement was evaluated using Passing and Bablok regression and Bland-Altman plot analysis. The receiver operating characteristic (ROC) curves were selected for evaluating the diagnostic agreement between OM classification and UF-BF parameters. RESULTS Comparison between UF-BF and OM, in all BF types, showed Passing and Bablok's slope comprised between 0.99 (polymorphonuclear cells count, PMN-BF) and 1.39 (mononuclear cells count, MN-BF), the intercepts ranged between 26.47 (PMN-BF parameter) and 226.80 (white blood cell count). Bland-Altman bias was comprised between 7.3% (total cell count, TC-BF) and 52.9% (MN-BF). Comparison between UF-BF and XN-BF in all BF showed slopes ranged between 1.07 (TC-BF and PMN-BF) and 1.16 (MN-BF), intercepts ranged between 8.30 (PMN) and 64.78 (WBC-BF). Bland-Altman bias ranged between 5.8 (TC-BF) and 21.1% (MN-BF). The ROC curve analysis showed an area under the curve ranged between 0.9664 and 1.000. CONCLUSIONS UF-BF shows very good performance for the differential counts of cells in ascitic, pleural and synovial fluids and therefore it is useful to screen and count cells in this type of BF.
Collapse
|
13
|
Liver injury in COVID-19 and IL-6 trans-signaling-induced endotheliopathy. J Hepatol 2021; 75:647-658. [PMID: 33991637 PMCID: PMC8285256 DOI: 10.1016/j.jhep.2021.04.050] [Citation(s) in RCA: 42] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/04/2021] [Revised: 04/23/2021] [Accepted: 04/26/2021] [Indexed: 02/07/2023]
Abstract
BACKGROUND AND AIMS COVID-19 is associated with liver injury and elevated interleukin-6 (IL-6). We hypothesized that IL-6 trans-signaling in liver sinusoidal endothelial cells (LSECs) leads to endotheliopathy (a proinflammatory and procoagulant state) and liver injury in COVID-19. METHODS Coagulopathy, endotheliopathy, and alanine aminotransferase (ALT) were retrospectively analyzed in a subset (n = 68), followed by a larger cohort (n = 3,780) of patients with COVID-19. Liver histology from 43 patients with COVID-19 was analyzed for endotheliopathy and its relationship to liver injury. Primary human LSECs were used to establish the IL-6 trans-signaling mechanism. RESULTS Factor VIII, fibrinogen, D-dimer, von Willebrand factor (vWF) activity/antigen (biomarkers of coagulopathy/endotheliopathy) were significantly elevated in patients with COVID-19 and liver injury (elevated ALT). IL-6 positively correlated with vWF antigen (p = 0.02), factor VIII activity (p = 0.02), and D-dimer (p <0.0001). On liver histology, patients with COVID-19 and elevated ALT had significantly increased vWF and platelet staining, supporting a link between liver injury, coagulopathy, and endotheliopathy. Intralobular neutrophils positively correlated with platelet (p <0.0001) and vWF (p <0.01) staining, and IL-6 levels positively correlated with vWF staining (p <0.01). IL-6 trans-signaling leads to increased expression of procoagulant (factor VIII, vWF) and proinflammatory factors, increased cell surface vWF (p <0.01), and increased platelet attachment in LSECs. These effects were blocked by soluble glycoprotein 130 (IL-6 trans-signaling inhibitor), the JAK inhibitor ruxolitinib, and STAT1/3 small-interfering RNA knockdown. Hepatocyte fibrinogen expression was increased by the supernatant of LSECs subjected to IL-6 trans-signaling. CONCLUSION IL-6 trans-signaling drives the coagulopathy and hepatic endotheliopathy associated with COVID-19 and could be a possible mechanism behind liver injury in these patients. LAY SUMMARY Patients with SARS-CoV-2 (severe acute respiratory syndrome coronavirus 2) infection often have liver injury, but why this occurs remains unknown. High levels of interleukin-6 (IL-6) and its circulating receptor, which form a complex to induce inflammatory signals, have been observed in patients with COVID-19. This paper demonstrates that the IL-6 signaling complex causes harmful changes to liver sinusoidal endothelial cells and may promote blood clotting and contribute to liver injury.
Collapse
|
14
|
Pathological characteristics of liver sinusoidal thrombosis in COVID-19 patients: A series of 43 cases. Hepatol Res 2021; 51:1000-1006. [PMID: 34260803 PMCID: PMC8444906 DOI: 10.1111/hepr.13696] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Revised: 06/06/2021] [Accepted: 06/29/2021] [Indexed: 02/05/2023]
Abstract
AIM Coronavirus disease (COVID-19) is characterized by pneumonia with secondary damage to multiple organs including the liver. Liver injury (elevated alanine aminotransferase [ALT] and aspartate aminotransferase [AST]) often correlates with disease severity in COVID-19 patients. The aim of this study is to identify pathological microthrombi in COVID-19 patient livers by correlating their morphology with liver injury, and examine hyperfibrinogenemia and von Willebrand factor (vWF) as mechanisms of their formation. METHODS Forty-three post-mortem liver biopsy samples from COVID-19 patients were obtained from Papa Giovanni XXIII Hospital in Bergamo, Italy. Three morphological features of microthrombosis (sinusoidal erythrocyte aggregation [SEA], platelet microthrombi [PMT], and fibrous thrombi) were evaluated. RESULTS We found liver sinusoidal microthrombosis in 23 COVID-19 patients (53%) was associated with a higher serum ALT and AST level compared to those without (ALT: 10-fold, p = 0.04; AST: 11-fold, p = 0.08). Of 43 livers, PMT and SEA were observed in 14 (33%) and 19 (44%) cases, respectively. Fibrous thrombi were not observed. Platelet microthrombi were associated with increased ALT (p < 0.01), whereas SEA was not (p = 0.73). In COVID-19 livers, strong vWF staining in liver sinusoidal endothelial cells was associated with significantly increased platelet adhesion (1.7-fold, p = 0.0016), compared to those with weak sinusoidal vWF (2-fold, p < 0.0001). Sinusoidal erythrocyte aggregation in 19 (83%) liver samples was mainly seen in zone 2. Livers with SEA had significantly higher fibrinogen (1.6-fold, p = 0.031) compared to those without SEA in COVID-19 patients. CONCLUSIONS Liver PMT is a pathologically important thrombosis associated with liver injury in COVID-19, while SEA is a unique morphological feature of COVID-19 patient livers. Sinusoidal vWF and hyperfibrinogenemia could contribute to PMT and SEA formation.
Collapse
|
15
|
A novel haemocytometric COVID-19 prognostic score developed and validated in an observational multicentre European hospital-based study. eLife 2020; 9:63195. [PMID: 33241996 PMCID: PMC7732342 DOI: 10.7554/elife.63195] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2020] [Accepted: 11/25/2020] [Indexed: 01/08/2023] Open
Abstract
COVID-19 induces haemocytometric changes. Complete blood count changes, including new cell activation parameters, from 982 confirmed COVID-19 adult patients from 11 European hospitals were retrospectively analysed for distinctive patterns based on age, gender, clinical severity, symptom duration, and hospital days. The observed haemocytometric patterns formed the basis to develop a multi-haemocytometric-parameter prognostic score to predict, during the first three days after presentation, which patients will recover without ventilation or deteriorate within a two-week timeframe, needing intensive care or with fatal outcome. The prognostic score, with ROC curve AUC at baseline of 0.753 (95% CI 0.723-0.781) increasing to 0.875 (95% CI 0.806-0.926) on day 3, was superior to any individual parameter at distinguishing between clinical severity. Findings were confirmed in a validation cohort. Aim is that the score and haemocytometry results are simultaneously provided by analyser software, enabling wide applicability of the score as haemocytometry is commonly requested in COVID-19 patients.
Collapse
|
16
|
What is the normal composition of pericardial fluid? Heart 2020; 107:1584-1590. [DOI: 10.1136/heartjnl-2020-317966] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Revised: 10/04/2020] [Accepted: 10/07/2020] [Indexed: 12/21/2022] Open
Abstract
ObjectiveBiochemical and cytological pericardial fluid (PF) analysis is essentially based on the knowledge of pleural fluid composition. The aim of the present study is to identify reference intervals (RIs) for PF according to state-of-art methodological standards.MethodsWe prospectively collected and analysed the PF and venous blood of consecutive subjects undergoing elective open-heart surgery from July 2017 to October 2018. Exclusion criteria for study enrolment were evidence of pericardial diseases at preoperatory workup or at intraoperatory assessment, or any other condition that could affect PF analysis.ResultsThe final study sample included 120 patients (median age 69 years, 83 men, 69.1%). The main findings were (1) High levels of proteins, albumin and lactate dehydrogenase (LDH), but not of glucose and cholesterol (2) High cellularity, mainly represented by mesothelial cells. RIs for pericardial biochemistry were: protein content 1.7–4.6 g/dL PF/serum protein ratio 0.29–0.83, albumin 1.19–3.06 g/dL, pericardium-to-serum albumin gradient 0.18–2.37 g/dL, LDH 141–2613 U/L, PF/serum LDH ratio 0.40–2.99, glucose 80–134 mg/dL, total cholesterol 12–69 mg/dL, PF/serum cholesterol ratio 0.07–0.51. RIs for pericardial cells by optic microscopy were: 278–5608 × 106 nucleated cells/L, 40–3790 × 106 mesothelial cells/L, 35–2210 × 106 leucocytes/L, 19–1634 × 106 lymphocytes/L.ConclusionsPF is rich in nucleated cells, protein, albumin, LDH, at levels consistent with inflammatory exudates in other biological fluids. Physicians should stop to interpret PF as exudate or transudate according to tools not validated for this setting.
Collapse
|
17
|
Standardization and harmonization in hematology: Instrument alignment, quality control materials, and commutability issue. Int J Lab Hematol 2020; 43:364-371. [PMID: 33174358 DOI: 10.1111/ijlh.13379] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2020] [Revised: 09/13/2020] [Accepted: 10/05/2020] [Indexed: 11/27/2022]
Abstract
INTRODUCTION In the hub and spoke laboratory network, the number of hematology analyzers (HAs) within each core center has increased, and the control of HAs alignment is becoming necessary requirement to ensure analytical quality. In this scenario, HA alignment can be assessed by analyzing the same control material used for internal quality control on multiple HAs, assuming its commutability. The aim of the study was to verify the applicability of a protocol for the alignment of HAs based on control material rather than on fresh whole-blood samples. METHODS The alignment of five HAs was evaluated for red (RBC, Hb, MCV, RET), white (WBC, NE, LY, MO, EO, BA, IG), and platelet (PLT) series parameters, following a protocol by SIBioC, using human sample (HS) and quality control material (QC), after the verification of commutability, according to the IFCC protocol. Maximum bias was derived from biological variation data. RESULTS A complete alignment between instruments was confirmed for the majority of the parameters investigated both for HS and QC material. Partial misalignments or inconcludent results were instead evident for MCV, MO, EO, BA, and IG. Interestingly, QC material was found to be not commutable for LY, MO, and BA. CONCLUSION The alignment of hematologic analyzers for main cell population parameters may be verified with both QC and HS, displaying consistent results and interpretation. The evaluation for some white series parameters (EO, BA, and IG) is critical, and particular attention must be paid to the values of the material used for the alignment.
Collapse
|
18
|
Positive tissue transglutaminase antibodies with negative endomysial antibodies: Unresolved issues in diagnosing celiac disease. J Immunol Methods 2020; 489:112910. [PMID: 33166550 DOI: 10.1016/j.jim.2020.112910] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2020] [Revised: 10/14/2020] [Accepted: 11/02/2020] [Indexed: 02/06/2023]
Abstract
BACKGROUND The serological screening for celiac disease (CD) is currently based on the detection of anti-transglutaminase (tTG) IgA antibodies, subsequently confirmed by positive endomysial antibodies (EMA). When an anti-tTG IgA positive/EMA IgA negative result occurs, it can be due either to the lower sensitivity of the EMA test or to the lower specificity of the anti-tTG test. This study aimed at verifying how variation in analytical specificity among different anti-tTG methods could account for this discrepancy. METHODS A total of 130 consecutive anti-tTG IgA positive/EMA negative samples were collected from the local screening routine and tested using five anti-tTG IgA commercial assays: two chemiluminescence methods, one fluoroimmunoenzymatic method, one immunoenzymatic method and one multiplex flow immunoassay method. RESULTS Twenty three/130 (17.7%) patients were diagnosed with CD. In the other 107 cases a diagnosis of CD was not confirmed. The overall agreement among the five anti-tTG methods ranged from 28.5% to 77.7%. CD condition was more likely linked to the positivity of more than one anti-tTG IgA assay (monopositive = 2.5%, positive with ≥ three methods = 29.5%; p = 0.0004), but it was not related to anti-tTG IgA antibody levels (either positive or borderline; p = 0.5). CONCLUSIONS Patients with positive anti-tTG/negative EMA have a low probability of being affected by CD. Given the high variability among methods to measure anti-tTG IgA antibodies, anti-tTG-positive/EMA-negative result must be considered with extreme caution. It is advisable that the laboratory report comments on any discordant results, suggesting to consider the data in the proper clinical context and to refer the patient to a CD reference center for prolonged follow up.
Collapse
|
19
|
Liver histopathology in severe COVID 19 respiratory failure is suggestive of vascular alterations. Liver Int 2020; 40:2110-2116. [PMID: 32654359 PMCID: PMC7404964 DOI: 10.1111/liv.14601] [Citation(s) in RCA: 189] [Impact Index Per Article: 47.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Revised: 07/03/2020] [Accepted: 07/06/2020] [Indexed: 12/12/2022]
Abstract
SARS2-CoV-2 breakout in Italy caused a huge number of severely ill patients with a serious increase in mortality. Although lungs seem to be the main target of the infection, very few information are available about liver involvement, possibly evocating a systemic disease. Post-mortem wedge liver biopsies from 48 patients died from severe pulmonary COVID-19 disease with respiratory failure were collected from two main hospitals in northern Italy. No patient had clinical symptoms of liver disease or signs of liver failure before and during hospitalization; for each of them liver function tests were available. All liver samples showed minimal inflammation features. Histological pictures compatible with vascular alterations were observed, characterized by increase in number of portal vein branches associated with lumen massive dilatation, partial or complete luminal thrombosis of portal and sinusoidal vessels, fibrosis of portal tract, focally markedly enlarged and fibrotic. SARS-CoV-2 was found in 15 of 22 samples tested by in situ hybridization method. Our preliminary results confirm the clinical impression that liver failure is not a main concern and this organ is not the target of significant inflammatory damage. Histopathological findings are highly suggestive for marked derangement of intrahepatic blood vessel network secondary to systemic changes induced by virus that could target not only lung parenchyma but also cardiovascular system, coagulation cascade and endothelial layer of blood vessels. It still remains unclear if the mentioned changes are directly related to virus infection or if SARS-CoV-2 triggers a series of reactions leading to striking vascular alterations.
Collapse
|
20
|
The pathogenesis of thromboembolic disease in covid-19 patients: Could be a catastrophic antiphospholipid syndrome? Thromb Res 2020; 194:192-194. [PMID: 32788116 PMCID: PMC7319923 DOI: 10.1016/j.thromres.2020.06.042] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2020] [Revised: 06/17/2020] [Accepted: 06/23/2020] [Indexed: 01/08/2023]
|
21
|
A new diagnostic algorithm for pattern-oriented autoantibody testing according to the ICAP nomenclature: A pilot study. Autoimmun Rev 2020; 19:102588. [PMID: 32540447 DOI: 10.1016/j.autrev.2020.102588] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2020] [Accepted: 02/14/2020] [Indexed: 12/31/2022]
Abstract
The commercial tests currently available as second-level tests to detect ANA sub-specificities are generally used independently from the ANA immunofluorescence (IIF) pattern. The aim of this study was to evaluate the efficacy of the use of a customizable pattern-oriented antigenic panel by immunoblot (IB) using the International Consensus on ANA Patterns (ICAP) classification scheme, in order to introduce a novel and updated autoimmune diagnostic flowchart. 710 sera referred for routine ANA testing were selected on the basis of the ANA pattern according to the ICAP nomenclature (nuclear speckled AC-2,4,5; nucleolar AC-8,9,10,29; cytoplasmic speckled AC-18,19,20) and on an IIF titer ≥1:320. They were then assayed by three experimental IB assays using a panel of selected antigens. ICAP-oriented IB detected 515 antibody reactivities vs. 457 of traditional anti-ENA in the nuclear speckled pattern group, 108 vs. 28 in the nucleolar pattern group, and 43 vs. 34 in the cytoplasmic speckled pattern. This pilot study may lead the way for a new approach introducing an ICAP pattern-oriented follow up testing as a valid alternative to the existing standard panels, thus enabling more patients with autoimmune rheumatic disease to be accurately diagnosed.
Collapse
|
22
|
A specific abnormal scattergram of peripheral blood leukocytes suggestive for the presence of proerythroblast. Scandinavian Journal of Clinical and Laboratory Investigation 2019; 80:55-58. [PMID: 31755781 DOI: 10.1080/00365513.2019.1692230] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
23
|
Preliminary evaluation of a new flow cytometry method for the routine hematology workflow. Clin Chem Lab Med 2019; 57:1608-1622. [PMID: 31556506 DOI: 10.1515/cclm-2018-1356] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2018] [Accepted: 03/10/2019] [Indexed: 11/15/2022]
Abstract
Background In a generalist laboratory, the integration of the data obtained from hematology analyzers (HAs) with those from multiparametric flow cytometry (FMC) could increase the specificity and sensitivity of first level screening to identify the pathological samples. The aim of this study was to perform a preliminary evaluation of a new simple hybrid method (HM). The method was obtained by integration between HAs reagents into FCM, with a basic monoclonal antibodies panel for the leukocytes differential count. Methods Eighty-one peripheral blood samples, collected in K3EDTA tubes, were analyzed by XN-module, and CyFlow Space System, using both standard MoAbs and HM method analysis, and with the optical microscopy (OM). Within-run imprecision was carried out using normal samples, the carryover was evaluated, data comparison was performed with Passing-Bablok regression and Bland-Altman plots. Results The within-run imprecision of HM methods ranged between 1.4% for neutrophils (NE) and 10.1% for monocytes (MO) always equal or lower to the OM. The comparison between HM methods vs. OM shows Passing-Bablok regression slopes comprised between 0.83 for lymphocyte (LY) and 1.14 for MO, whilst the intercepts ranged between -0.18 for NE and 0.25 for LY. Bland-Altman relative bias was comprised between -12.43% for NE, and 19.77% for eosinophils. In all 11 pathological samples the agreement between the methods was 100%. Conclusions The new hybrid method generates a leukocytes differential count suitable for routine clinical use and it is also useful for identifying morphological abnormalities with a reduction in cost and improvement of screening for first level hematology workflow.
Collapse
|
24
|
Mozhaisk haemoglobin variant effects on leukocyte differential channel using the Sysmex XN series. ACTA ACUST UNITED AC 2019; 57:e324-e327. [DOI: 10.1515/cclm-2019-0373] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2019] [Accepted: 05/27/2019] [Indexed: 11/15/2022]
|
25
|
Comparison between optical microscopy and automation for cytometric analysis of pericardial fluids in a cohort of adult subjects undergoing cardiac surgery. J Clin Pathol 2019; 72:493-500. [DOI: 10.1136/jclinpath-2019-205788] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2019] [Revised: 03/28/2019] [Accepted: 03/28/2019] [Indexed: 01/04/2023]
Abstract
AimsLimited information is available on number and type of cells present in the pericardial fluid (PF). Current evidence and has been garnered with inaccurate application of guidelines for analysis of body fluids. This study was aimed at investigating the performance of automate cytometric analysis of PF in adult subjects.MethodsSeventy-four consecutive PF samples were analysed with Sysmex XN with a module for body fluid analysis (XN-BF) and optical microscopy (OM). The study also encompassed the assessment of limit of blank, limit of detection and limit of quantitation (LoQ), imprecision, carryover and linearity of XN-BF module.ResultsXN-BF parameters were compared with OM for the following cell classes: total cells (TC), leucocytes (white blood cell [WBC]), polymorphonuclear (PMN) and mononuclear (MN) cells. The relative bias were −4.5%, 71.2%, 108.2% and −47.7%, respectively. Passing and Bablok regression yielded slope comprised between 0.06 for MN and 5.8 for PMN, and intercept between 0.7 for PMN and 220.3 for MN. LoQ was comprised between 3.8×106 and 6.0×106 cells/L for WBC and PMN. Linearity was acceptable and carryover negligible.ConclusionsPF has a specific cellular composition. Overall, automated cell counting can only be suggested for total number of cells, whereas OM seems still the most reliable option for cell differentiation.
Collapse
|
26
|
Lack of harmonization in high fluorescent cell automated counts with body fluids mode in ascitic, pleural, synovial, and cerebrospinal fluids. Int J Lab Hematol 2019; 41:277-286. [PMID: 30758900 DOI: 10.1111/ijlh.12968] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2018] [Revised: 11/28/2018] [Accepted: 12/12/2018] [Indexed: 12/17/2022]
Abstract
INTRODUCTION Cellular analysis in body fluids (BFs) provides important diagnostic information in various pathological settings. This study was hence aimed at comparing automated cell count obtained with Mindray BC-6800 (BC-BF) vs Sysmex XN-series (XN-BF) and evaluating other quantitative and qualitative information provided by these analyzers in ascitic (AF), pleural (PF), synovial (SF), and cerebrospinal (CSF) fluids. METHODS Three hundred and fifty-one samples (99 AFs, 45 PFs, 75 SFs, and 132 CSFs) were analyzed in parallel with BC-BF, XN-BF, and optical microscopy (OM). The study also included the assessment of diagnostic agreement among BC-BF, XN-BF, and OM. RESULTS The comparison of BC-BF vs XN-BF yielded slopes of Passing and Bablok regression always comprised between 0.9 and 1.0 except for EO-BF and HF-BF, whilst the intercepts ranged from -0.4 for MN-BF and 12.0 for PMN-BF. The bias was comprised between -103.3% and 67.1% for HF-BF and EO-BF, respectively. A significant bias was found for TC-BF, WBC-BF, HF-BF (negative bias) and for PMN-BF and EO-BF (positive bias). The agreement (Cohen's kappa) between XN-BF and BC-BF was always ≥0.7, ranging between 0.87 in CSFs and 0.94 in AFs, and that with OM was similar (ie, 0.85 and 0.96). CONCLUSION The cytometric analysis of BF samples using BC-BF and XN-BF is clinically favorable when appropriately combined with OM. Quantitative and qualitative parameters displayed optimal agreement, whilst instrument-specific cut-offs should be defined and implemented for HF-BF and EO-BF. Further efforts should be made for achieving better harmonization in cytometric analysis of BF samples.
Collapse
|
27
|
Combining immunofluorescence with immunoblot assay improves the specificity of autoantibody testing for myositis. Rheumatology (Oxford) 2019; 58:1239-1244. [DOI: 10.1093/rheumatology/key451] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2018] [Revised: 12/19/2018] [Indexed: 01/25/2023] Open
|
28
|
A Preliminary Proposal for Quality Control Assessment and Harmonization of Leukocytes Morphology-structural Parameters (cell Population Data Parameters). J Med Biochem 2018; 37:486-498. [PMID: 30584409 PMCID: PMC6298477 DOI: 10.2478/jomb-2018-0005] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2018] [Accepted: 02/21/2018] [Indexed: 02/03/2023] Open
Abstract
BACKGROUND The cell population data (CPD) measured by Sysmex XN-9000 can be used for screening many hematological and non-hematological disorders. Since little information is available on harmonization of CPD among different instrumentation and clinical laboratories, this study aimed at assessing the current degree of CPD harmonization between separate Sysmex XN modules allocated to the same laboratory. METHODS A total number of 78291 data were used for verification of within-run imprecision, analyzers harmonization, reference ranges and assessment of blood sample stability of CPD parameters, including results of daily quality control testing and those generated in samples collected from blood donors and healthy volunteers. RESULTS Within-run imprecision of CPD parameters ranged between 0.4 and 14.1%. Good agreement was found among five different XN-modules, especially when values were adjusted after calculation of instrument-specific alignment factors. The bias of all parameters remained always lower than the reference change values in samples stored for up to 8 hours, regardless of storage temperature. CONCLUSIONS The imprecision of CPD parameters was acceptable, except for those reflecting the dispersion of cellular clusters. Due to the lack of reference control materials, we showed that the use of data generated on a large number of normal routine samples (i.e., a Moving Average population) may be a reliable approach for testing analyzers harmonization. Nevertheless, availability of both calibration and quality control materials for these parameters is highly advisable in the future. We finally showed that whole blood samples may be stable for up to 2-4 hours for most CPD parameters.
Collapse
|
29
|
Evaluation and comparison of automated hematology analyzer, flow cytometry, and digital morphology analyzer for monocyte counting. Int J Lab Hematol 2018; 40:577-585. [DOI: 10.1111/ijlh.12868] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2018] [Accepted: 04/25/2018] [Indexed: 12/18/2022]
|
30
|
The association of solid-phase assays to immunofluorescence increases the diagnostic accuracy for ANA screening in patients with autoimmune rheumatic diseases. Autoimmun Rev 2018; 17:541-547. [PMID: 29631063 DOI: 10.1016/j.autrev.2017.12.007] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2017] [Accepted: 12/08/2017] [Indexed: 12/11/2022]
|
31
|
A specific abnormal scattergram of peripheral blood leukocytes that may suggest hairy cell leukemia. ACTA ACUST UNITED AC 2017; 56:e108-e111. [DOI: 10.1515/cclm-2017-0763] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2017] [Accepted: 10/31/2017] [Indexed: 11/15/2022]
|
32
|
Preliminary evaluation of UF-5000 Body Fluid Mode for automated cerebrospinal fluid cell counting. Clin Chim Acta 2017; 473:133-138. [DOI: 10.1016/j.cca.2017.08.026] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2017] [Revised: 08/22/2017] [Accepted: 08/22/2017] [Indexed: 11/16/2022]
|
33
|
Performance evaluation of the new fully automated urine particle analyser UF-5000 compared to the reference method of the Fuchs-Rosenthal chamber. Clin Chim Acta 2017; 472:123-130. [PMID: 28760666 DOI: 10.1016/j.cca.2017.07.028] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2017] [Accepted: 07/28/2017] [Indexed: 10/19/2022]
Abstract
BACKGROUND UF-5000 is the new fully automated urine particle analyser. We validated its performance. METHODS 736 urines were analysed and results were compared by two pathologists on uncentrifuged samples, using Fuchs-Rosenthal chamber. RESULTS AUC of ROC curve ranged between 0.86 and 0.99. Sensitivity was >0.90 for all the elements and similar for RBC and yeasts. Specificity ranged between 0.74 and 0.89 for total cast, epithelial/non-squamous/renal-tubular cells and RBC. For all the other parameters specificity was >0.90. Comparison with Fuchs-Rosenthal chamber was very good for all the parameters; r ranged between 0.52 and 0.99 except for pathological cast because of the lack of the pathological samples in medium and higher ranges. Linearity performance (R2) was 1.00, 1.00 and 0.99 respectively for RBC, WBC and epithelial cells (EC). No carry-over was observed. The within-run imprecision was 25.42%,13.81%,1.36% for RBC; 37.50%,10.16%,1.41% for WBC and 35.25%, 17.85%,6.30% for EC at low, near the cut off level and high concentrations, respectively. The between-run imprecision was 6.90%,1.60% for RBC, 4.10%,1.90% for WBC and 7.60%,7.30% for EC, using low and high positive quality controls, respectively. CONCLUSION UF-5000 is an analyser of great interest to detect urine particle related to pathological process of kidney and urinary tract.
Collapse
|
34
|
[Current therapeutic indications and possibilities in prolonged respiratory insufficiency (collective review) ]. CHIRURGIA ITALIANA 1978; 30:394-100. [PMID: 354816] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
The article provides a synthetic review of the most current problems of treatment of acute respiratory insufficiency refractory to standard and conventional therapeutic remedies using extracorporal membrane gas exchangers. On the basis of a review of the literature on the subject, the advantages and disadvantages of each main type of oxygenator are considered and critically evaluated with regard to metabolic, haemodynamic and circulatroy activity and the repercussions of each resuscitation technique on haemocoagulation.
Collapse
|
35
|
[Problems of anesthesia and resuscitation in drepanocytic anemia]. CHIRURGIA ITALIANA 1976; 28:882-90. [PMID: 1029535] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
A study was made of anesthesiological and resuscitation problems in 18 patients suffering from drepanocytic anemia. An examination of the results showed that the anesthesiological problems do not so much concern selection of the anesthetic as a knowledge of the physiopathology of this disease, i.e. the tendency to bronchopulmonary complications as a result of the increased viscosity of the blood, the increased mechanical fragility of the erythrocytes, and erythrostasis, with consequent rise of ischaemic necrosis and damage to the various parenchymas. It was also observed that pulmonary complications occurred more frequently in preoperatively transfused patients.
Collapse
|
36
|
[Renal resistance in ethrane anesthesia]. CHIRURGIA ITALIANA 1976; 28:891-6. [PMID: 1029536] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
The indices of renal functionality are studied during the course of ether anesthesia in order to ascertain the behaviour of the kidney subjected to narcosis with this drug. A sharp reduction in the minute volume of F.G. and P.R.E. is evidenced, together with an increase in renal resistances, especially as regards the efferent sector. These changes, which are established at the start of anesthesiological treatment, tend to decrease in intensity as narcosis continues. This picture is interpreted as being due to the concomitant action of two factors: a decrease in cardiac output on the one hand, and an increased incretion of catecholamines leading to renal arteriolar vasoconstriction on the other.
Collapse
|
37
|
[Circulatory flow during anesthesia with enflurane]. CHIRURGIA ITALIANA 1976; 28:897-906. [PMID: 1029537] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
The rebreathing technique was used to study the behaviour of the circulatory flow in patients operated under ether anesthesia. It was observed that during ether narcosis the circulatory flow values show a fair drop at the readings made 30' and 45' after the inductive period. 60' after the start of ether narcosis the circulatory flow values show a tendency to increase, and these observations are accentuated in the readings taken at 75' and 90'.
Collapse
|