1
|
New initiation of opioids, benzodiazepines and antipsychotics following hospitalization for COVID-19. J Hosp Med 2024. [PMID: 38742528 DOI: 10.1002/jhm.13408] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Revised: 04/30/2024] [Accepted: 05/03/2024] [Indexed: 05/16/2024]
Abstract
BACKGROUND Patients newly initiated on opioids (OP), benzodiazepines (BZD), and antipsychotics (AP) during hospitalization are often prescribed these on discharge. Implications of this practice on outcomes remains unexplored. OBJECTIVE To explore the prevalence and risk factors of new initiation of select OP, BZD and AP among patients requiring in-patient stays. Test the hypothesis that new prescriptions are associated with higher odds of readmission or death within 28 days of discharge. DESIGN Single center retrospective cohort study. SETTING AND PARTICIPANTS Patients admitted to a tertiary-level medical center with either a primary diagnosis of RT-PCR positive for COVID-19 or high index of clinical suspicion thereof. INTERVENTION None. MAIN OUTCOME AND MEASURES Exposure was the new initiation of select common OP, BZD, and AP which were continued on hospital discharge. Outcome was a composite of 28-day readmission or death following index admission. Multivariable logistic regression was used to assess patient mortality or readmission within 28 days of discharge associated with new prescriptions at discharge. RESULTS One thousand three hundred and nineteen patients were included in the analysis. 11.3% (149/1319) were discharged with a new prescription of select OP, BZD, or AP either alone or in combination. OP (110/149) were most prescribed followed by BZD (41/149) and AP (22/149). After adjusting for unbalanced confounders, new prescriptions (adjusted odds ratio: 2.44, 95% confidence interval: 1.42-4.12; p = .001) were associated with readmission or death within 28 days of discharge. One in nine patients admitted with a diagnosis of COVID-19 or high clinical suspicion thereof were discharged with a new prescription of either OP, BZD or AP. New prescriptions were associated with higher odds of 28-day readmission or death. Strengthening medication reconciliation processes focused on these classes may reduce avoidable harm.
Collapse
|
2
|
Determination of Spin-Parity Quantum Numbers of X(2370) as 0^{-+} from J/ψ→γK_{S}^{0}K_{S}^{0}η^{'}. PHYSICAL REVIEW LETTERS 2024; 132:181901. [PMID: 38759175 DOI: 10.1103/physrevlett.132.181901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Revised: 03/05/2024] [Accepted: 03/28/2024] [Indexed: 05/19/2024]
Abstract
Based on (10087±44)×10^{6} J/ψ events collected with the BESIII detector, a partial wave analysis of the decay J/ψ→γK_{S}^{0}K_{S}^{0}η^{'} is performed. The mass and width of the X(2370) are measured to be 2395±11(stat)_{-94}^{+26}(syst) MeV/c^{2} and 188_{-17}^{+18}(stat)_{-33}^{+124}(syst) MeV, respectively. The corresponding product branching fraction is B[J/ψ→γX(2370)]×B[X(2370)→f_{0}(980)η^{'}]×B[f_{0}(980)→K_{S}^{0}K_{S}^{0}]=(1.31±0.22(stat)_{-0.84}^{+2.85}(syst))×10^{-5}. The statistical significance of the X(2370) is greater than 11.7σ and the spin parity is determined to be 0^{-+} for the first time. The measured mass and spin parity of the X(2370) are consistent with the predictions of the lightest pseudoscalar glueball.
Collapse
|
3
|
Increased Postoperative Opioid Consumption in the Presence of Co-administration of 5-HT3 Antagonists with Acetaminophen: A Hospital Registry Study. Anesthesiology 2024:140099. [PMID: 38700445 DOI: 10.1097/aln.0000000000005033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/05/2024]
Abstract
BACKGROUND Acetaminophen and 5-hydroxytryptamine-type-3 (5-HT3) receptor antagonists are administered as standard prophylaxes for postoperative pain, nausea, and vomiting. Preclinical studies however suggest that 5-HT3 antagonists may compromise acetaminophen's analgesic effect. This hospital registry study investigates whether 5-HT3 antagonists mitigate the analgesic effect of prophylactic acetaminophen in a perioperative setting. METHODS This study included 55,016 adult patients undergoing general anesthesia for ambulatory procedures at a tertiary healthcare center in Massachusetts, United States of America, from 2015 to 2022. Using binary exposure variables and a comprehensive selection of pre-planned patient- and procedure-related covariates for confounder control, we investigated whether intraoperative 5-HT3 antagonists affected the association between pre- or intraoperative acetaminophen and postoperative opioid consumption, gauged by opioid dose in mg oral morphine equivalents (OME) administered in the post-anesthesia care unit (PACU). A multivariable, zero-inflated negative binomial regression model was applied. RESULTS 3,166 (5.8%) patients received only acetaminophen, 15,438 (28.1%) only 5-HT3 antagonists, 31,850 (57.9%) both drugs, and 4,562 (8.3%) neither drug. The median PACU opioid dose was 7.5 mg OME (interquartile range 7.5 to 14.3 mg OME) among 16,640/55,016 (30.3%) patients who received opioids and the average opioid dose was 3.2 mg OME across all patients (maximum cumulative dose: 20.4 mg OME). Acetaminophen administration was associated with a 5.5% (95%CI -9.6% to -1.4%;p=0.009; adjusted absolute difference -0.19 mg OME;95%CI -0.33 to -0.05;p=0.009) reduction in opioid consumption among patients who did not receive a 5-HT3 antagonist, while there was no effect in patients who received a 5-HT3 antagonist (adjusted absolute difference 0.00 mg OME; 95%CI -0.06 to 0.05;p=0.93,p-for-interaction=0.012). CONCLUSION A dose-dependent association of pre- or intraoperative acetaminophen with decreased postoperative opioid consumption was not observed when 5-HT3 antagonists were co-administered, suggesting that physicians might consider reserving 5-HT3 antagonists as rescue medication for postoperative nausea or vomiting when acetaminophen is administered for pain prophylaxis.
Collapse
|
4
|
Recovery and safety with prolonged high-frequency jet ventilation for catheter ablation of atrial fibrillation: A hospital registry study from a New England healthcare network. J Clin Anesth 2024; 93:111324. [PMID: 38000222 DOI: 10.1016/j.jclinane.2023.111324] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Revised: 10/24/2023] [Accepted: 11/12/2023] [Indexed: 11/26/2023]
Abstract
STUDY OBJECTIVE To investigate post-procedural recovery as well as peri-procedural respiratory and hemodynamic safety parameters with prolonged use of high-frequency jet ventilation (HFJV) versus conventional ventilation in patients undergoing catheter ablation for atrial fibrillation. DESIGN Hospital registry study. SETTING Tertiary academic teaching hospital in New England. PATIENTS 1822 patients aged 18 years and older undergoing catheter ablation between January 2013 and June 2020. INTERVENTIONS HFJV versus conventional mechanical ventilation. MEASUREMENTS The primary outcome was post-anesthesia care unit (PACU) length of stay. In secondary analyses we assessed the effect of HFJV on intra-procedural hypoxemia, defined as the occurrence of peripheral hemoglobin oxygen saturation (SpO2) <90%, post-procedural respiratory complications (PRC) as well as intra-procedural hypocarbia and hypotension. Multivariable negative binomial and logistic regression analyses, adjusted for patient and procedural characteristics, were applied. MAIN RESULTS 1157 patients (63%) received HFJV for a median (interquartile range [IQR]) duration of 307 (253-360) minutes. The median (IQR) length of stay in the PACU was 244 (172-370) minutes in patients who underwent ablation with conventional mechanical ventilation and 226 (163-361) minutes in patients receiving HFJV. In adjusted analyses, patients undergoing HFJV had a longer PACU length of stay (adjusted absolute difference: 37.7 min; 95% confidence interval [CI] 9.7-65.8; p = 0.008). There was a higher risk of intra-procedural hypocarbia (adjusted odds ratio [ORadj] 5.90; 95%CI 2.63-13.23; p < 0.001) and hypotension (ORadj 1.88; 95%CI 1.31-2.72; p = 0.001) in patients undergoing HFJV. No association was found between the use of HFJV and intra-procedural hypoxemia or PRC (p = 0.51, and p = 0.97, respectively). CONCLUSION After confounder adjustment, HFJV for catheter ablation procedures for treatment of atrial fibrillation was associated with a longer length of stay in the PACU. It was further associated with an increased risk of intra-procedural abnormalities including abnormal carbon dioxide homeostasis, as well as intra-procedural arterial hypotension.
Collapse
|
5
|
Observation of Structures in the Processes e^{+}e^{-}→ωχ_{c1} and ωχ_{c2}. PHYSICAL REVIEW LETTERS 2024; 132:161901. [PMID: 38701481 DOI: 10.1103/physrevlett.132.161901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/26/2024] [Revised: 03/13/2024] [Accepted: 03/22/2024] [Indexed: 05/05/2024]
Abstract
We present measurements of the Born cross sections for the processes e^{+}e^{-}→ωχ_{c1} and ωχ_{c2} at center-of-mass energies sqrt[s] from 4.308 to 4.951 GeV. The measurements are performed with data samples corresponding to an integrated luminosity of 11.0 fb^{-1} collected with the BESIII detector operating at the Beijing Electron Positron Collider storage ring. Assuming the e^{+}e^{-}→ωχ_{c2} signals come from a single resonance, the mass and width are determined to be M=(4413.6±9.0±0.8) MeV/c^{2} and Γ=(110.5±15.0±2.9) MeV, respectively, which is consistent with the parameters of the well-established resonance ψ(4415). In addition, we also use one single resonance to describe the e^{+}e^{-}→ωχ_{c1} line shape and determine the mass and width to be M=(4544.2±18.7±1.7) MeV/c^{2} and Γ=(116.1±33.5±1.7) MeV, respectively. The structure of this line shape, observed for the first time, requires further understanding.
Collapse
|
6
|
Coupled-Channel Analysis of the χ_{c1}(3872) Line Shape with BESIII Data. PHYSICAL REVIEW LETTERS 2024; 132:151903. [PMID: 38682963 DOI: 10.1103/physrevlett.132.151903] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 01/03/2024] [Accepted: 03/11/2024] [Indexed: 05/01/2024]
Abstract
We perform a study of the χ_{c1}(3872) line shape using the data samples of e^{+}e^{-}→γχ_{c1}(3872), χ_{c1}(3872)→D^{0}D[over ¯]^{0}π^{0}, and π^{+}π^{-}J/ψ collected with the BESIII detector. The effects of the coupled channels and the off-shell D^{*0} are included in the parametrization of the line shape. The line shape mass parameter is obtained to be M_{X}=(3871.63±0.13_{-0.05}^{+0.06}) MeV. Two poles are found on the first and second Riemann sheets corresponding to the D^{*0}D[over ¯]^{0} branch cut. The pole location on the first sheet is much closer to the D^{*0}D[over ¯]^{0} threshold than the other, and is determined to be 7.04±0.15_{-0.08}^{+0.07} MeV above the D^{0}D[over ¯]^{0}π^{0} threshold with an imaginary part -0.19±0.08_{-0.19}^{+0.14} MeV.
Collapse
|
7
|
Observation of the Anomalous Shape of X(1840) in J/ψ→γ3(π^{+}π^{-}) Indicating a Second Resonance Near pp[over ¯] Threshold. PHYSICAL REVIEW LETTERS 2024; 132:151901. [PMID: 38682972 DOI: 10.1103/physrevlett.132.151901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Revised: 01/16/2024] [Accepted: 02/23/2024] [Indexed: 05/01/2024]
Abstract
Using a sample of (10087±44)×10^{6} J/ψ events, which is about 45 times larger than that was previously analyzed, a further investigation on the J/ψ→γ3(π^{+}π^{-}) decay is performed. A significant distortion at 1.84 GeV/c^{2} in the line shape of the 3(π^{+}π^{-}) invariant mass spectrum is observed for the first time, which could be resolved by two overlapping resonant structures, X(1840) and X(1880). The new state X(1880) is observed with a statistical significance larger than 10σ. The mass and width of X(1880) are determined to be 1882.1±1.7±0.7 MeV/c^{2} and 30.7±5.5±2.4 MeV, respectively, which indicates the existence of a pp[over ¯] bound state.
Collapse
|
8
|
Study of the f_{0}(980) and f_{0}(500) Scalar Mesons through the Decay D_{s}^{+}→π^{+}π^{-}e^{+}ν_{e}. PHYSICAL REVIEW LETTERS 2024; 132:141901. [PMID: 38640399 DOI: 10.1103/physrevlett.132.141901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/23/2023] [Revised: 11/29/2023] [Accepted: 02/28/2024] [Indexed: 04/21/2024]
Abstract
Using e^{+}e^{-} collision data corresponding to an integrated luminosity of 7.33 fb^{-1} recorded by the BESIII detector at center-of-mass energies between 4.128 and 4.226 GeV, we present an analysis of the decay D_{s}^{+}→π^{+}π^{-}e^{+}ν_{e}, where the D_{s}^{+} is produced via the process e^{+}e^{-}→D_{s}^{*±}D_{s}^{∓}. We observe the f_{0}(980) in the π^{+}π^{-} system and the branching fraction of the decay D_{s}^{+}→f_{0}(980)e^{+}ν_{e} with f_{0}(980)→π^{+}π^{-} measured to be (1.72±0.13_{stat}±0.10_{syst})×10^{-3}, where the uncertainties are statistical and systematic, respectively. The dynamics of the D_{s}^{+}→f_{0}(980)e^{+}ν_{e} decay are studied with the simple pole parametrization of the hadronic form factor and the Flatté formula describing the f_{0}(980) in the differential decay rate, and the product of the form factor f_{+}^{f_{0}}(0) and the c→s Cabibbo-Kobayashi-Maskawa matrix element |V_{cs}| is determined for the first time to be f_{+}^{f_{0}}(0)|V_{cs}|=0.504±0.017_{stat}±0.035_{syst}. Furthermore, the decay D_{s}^{+}→f_{0}(500)e^{+}ν_{e} is searched for the first time but no signal is found. The upper limit on the branching fraction of D_{s}^{+}→f_{0}(500)e^{+}ν_{e}, f_{0}(500)→π^{+}π^{-} decay is set to be 3.3×10^{-4} at 90% confidence level.
Collapse
|
9
|
Intraoperative Opioid Waste and Association of Intraoperative Opioid Dose with Postoperative Adverse Outcomes: A Hospital Registry Study. Pain Ther 2024; 13:211-225. [PMID: 38281221 DOI: 10.1007/s40122-023-00574-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2023] [Accepted: 12/29/2023] [Indexed: 01/30/2024] Open
Abstract
INTRODUCTION Perioperative opioid use has been associated with adverse clinical outcomes. Additionally, opioid disposal carries significant costs, due to the waste of pharmaceutical products and the time needed by skilled labor to report the waste. In this study, we aimed to estimate costs and predict factors of opioid-associated intraoperative product waste, as well as to evaluate whether higher intraoperative opioid doses are associated with increased risk of adverse postoperative outcomes. METHODS We included 170,607 patients undergoing general anesthesia and receiving intraoperative fentanyl, hydromorphone, or morphine at Beth Israel Deaconess Medical Center, Boston, MA, USA, between January 2010 and June 2020. We estimated product waste-associated costs based on various opioid syringe sizes and determined predictors of opioid waste. Further, we evaluated whether higher opioid doses were associated with postoperative adverse events according to the severity-indexed, incident report-based medication error-reporting program classification. The primary outcome included post-extubation desaturation, postoperative nausea or vomiting, or postoperative somnolence or sedation. RESULTS The use of the smallest syringe sizes (50 mcg for fentanyl, 0.2 mg for hydromorphone, and 2 mg for morphine) resulted in the lowest product waste-associated costs. The main predictor of opioid waste was the administration of more than one intraoperative opioid (adjusted odds ratio [aOR] = 7.64, 95% CI 7.40-7.89, P < 0.001). Intraoperative doses of fentanyl > 50-100 mcg (aOR = 1.17 [1.10-1.25], P < 0.001, adjusted risk difference [ARD] 2%) and > 100 mcg (aOR = 1.24 [1.16-1.33], P < 0.001, ARD 3%), hydromorphone > 1 mg (aOR = 1.13 [1.06-1.20], P < 0.001, ARD 2%), and morphine > 2-4 mg (aOR = 1.26 [1.02-1.56], P = 0.04, ARD 3%) and > 4 mg (aOR = 1.45 [1.18-1.77], P < 0.001, ARD 5%) were associated with higher risk of the primary outcome. CONCLUSION Smaller syringe sizes of intraoperative opioids may help to reduce product waste and associated costs, as well postoperative adverse events through utilization of lower intraoperative opioid doses.
Collapse
|
10
|
Construct validation of machine learning for accurately predicting the risk of postoperative surgical site infection following spine surgery. J Hosp Infect 2024; 146:232-241. [PMID: 38029857 DOI: 10.1016/j.jhin.2023.09.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2023] [Revised: 09/15/2023] [Accepted: 09/22/2023] [Indexed: 12/01/2023]
Abstract
BACKGROUND This study aimed to evaluate the risk factors for machine learning (ML) algorithms in predicting postoperative surgical site infection (SSI) following spine surgery. METHODS This prospective cohort study included 986 patients who underwent spine surgery at Taizhou People's Hospital Affiliated to Nanjing Medical University from January 2015 to October 2022. Supervised ML algorithms included support vector machine, logistic regression, random forest, XGboost, decision tree, k-nearest neighbour, and naïve Bayes (NB), which were tested and trained to develop a predicting model. The ML model performance was evaluated from the test dataset. We gradually analysed their accuracy, sensitivity, and specificity, as well as the positive predictive value, negative predictive value, and area under the curve. RESULTS The rate of SSI was 9.33%. Using a backward stepwise approach, we identified that the remarkable risk factors predicting SSI in the multi-variate Cox regression analysis were age, body mass index, smoking, cerebrospinal fluid leakage, drain duration and pre-operative albumin level. Compared with other ML algorithms, the NB model had the highest performance in seven ML models, with an average area under the curve of 0.95, sensitivity of 0.78, specificity of 0.88, and accuracy of 0.87. CONCLUSIONS The NB model in the ML algorithm had excellent calibration and accurately predicted the risk of SSI compared with the existing models, and might serve as an important tool for the early detection and treatment of SSI following spinal infection.
Collapse
|
11
|
[A case of fibrillary glomerulonephritis with relatively slow progression]. ZHONGHUA NEI KE ZA ZHI 2024; 63:412-415. [PMID: 38561288 DOI: 10.3760/cma.j.cn112138-20231103-00294] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 04/04/2024]
|
12
|
Observation of D^{+}→K_{S}^{0}a_{0}(980)^{+} in the Amplitude Analysis of D^{+}→K_{S}^{0}π^{+}η. PHYSICAL REVIEW LETTERS 2024; 132:131903. [PMID: 38613307 DOI: 10.1103/physrevlett.132.131903] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2023] [Revised: 01/10/2024] [Accepted: 02/14/2024] [Indexed: 04/14/2024]
Abstract
We perform for the first time an amplitude analysis of the decay D^{+}→K_{S}^{0}π^{+}η and report the observation of the decay D^{+}→K_{S}^{0}a_{0}(980)^{+} using 2.93 fb^{-1} of e^{+}e^{-} collision data taken at a center-of-mass energy of 3.773 GeV with the BESIII detector. As the only W-annihilation-free decay among D to a_{0}(980) pseudoscalar, D^{+}→K_{S}^{0}a_{0}(980)^{+} is the ideal decay in extracting the contributions of the W-emission amplitudes involving a_{0}(980) and to study the final-state interactions. The absolute branching fraction of D^{+}→K_{S}^{0}π^{+}η is measured to be (1.27±0.04_{stat}±0.03_{syst})%. The branching fractions of intermediate processes D^{+}→K_{S}^{0}a_{0}(980)^{+} with a_{0}(980)^{+}→π^{+}η and D^{+}→π^{+}K[over ¯]_{0}^{*}(1430)^{0} with K[over ¯]_{0}^{*}(1430)^{0}→K_{S}^{0}η are measured to be (1.33±0.05_{stat}±0.04_{syst})% and (0.14±0.03_{stat}±0.01_{syst})%, respectively.
Collapse
|
13
|
Observation of Significant Flavor-SU(3) Breaking in the Kaon Wave Function at 12<Q^{2}<25 GeV^{2} and Discovery of the Charmless Decay ψ(3770)→K_{S}^{0}K_{L}^{0}. PHYSICAL REVIEW LETTERS 2024; 132:131901. [PMID: 38613263 DOI: 10.1103/physrevlett.132.131901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Revised: 02/11/2024] [Accepted: 02/13/2024] [Indexed: 04/14/2024]
Abstract
We present cross sections for the reaction e^{+}e^{-}→K_{S}^{0}K_{L}^{0} at center-of-mass energies ranging from 3.51 to 4.95 GeV using data samples collected in the BESIII experiment, corresponding to a total integrated luminosity of 26.5 fb^{-1}. The ratio of neutral-to-charged kaon form factors at large momentum transfers (12
Collapse
|
14
|
Investigation of the ΔI=1/2 Rule and Test of CP Symmetry through the Measurement of Decay Asymmetry Parameters in Ξ^{-} Decays. PHYSICAL REVIEW LETTERS 2024; 132:101801. [PMID: 38518329 DOI: 10.1103/physrevlett.132.101801] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2023] [Accepted: 02/01/2024] [Indexed: 03/24/2024]
Abstract
Using (10087±44)×10^{6} J/ψ events collected with the BESIII detector, numerous Ξ^{-} and Λ decay asymmetry parameters are simultaneously determined from the process J/ψ→Ξ^{-}Ξ[over ¯]^{+}→Λ(pπ^{-})π^{-}Λ[over ¯](n[over ¯]π^{0})π^{+} and its charge-conjugate channel. The precisions of α_{Λ0} for Λ→nπ^{0} and α[over ¯]_{Λ0} for Λ[over ¯]→n[over ¯]π^{0} compared to world averages are improved by factors of 4 and 1.7, respectively. The ratio of decay asymmetry parameters of Λ→nπ^{0} to that of Λ→pπ^{-}, ⟨α_{Λ0}⟩/⟨α_{Λ-}⟩, is determined to be 0.873±0.012_{-0.010}^{+0.011}, where the first and the second uncertainties are statistical and systematic, respectively. The ratio is smaller than unity more than 5σ, which signifies the existence of the ΔI=3/2 transition in Λ for the first time. Besides, we test for CP symmetry in Ξ^{-}→Λπ^{-} and in Λ→nπ^{0} with the best precision to date.
Collapse
|
15
|
Bayesian Hierarchical Network Autocorrelation Models for Estimating Direct and Indirect Effects of Peer Hospitals on Outcomes of Hospitalized Patients. RESEARCH SQUARE 2024:rs.3.rs-4014583. [PMID: 38496605 PMCID: PMC10942573 DOI: 10.21203/rs.3.rs-4014583/v1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/19/2024]
Abstract
When an hypothesized peer effect (also termed social influence or contagion) is believed to act between units (e.g., hospitals) above the level at which data is observed (e.g., patients), a network autocorrelation model may be embedded within a hierarchical data structure thereby formulating the peer effect as a dependency between latent variables. In such a situation, a patient's own hospital can be thought of as a mediator between the effects of peer hospitals and their outcome. However, as in mediation analyses, there may be interest in allowing the effects of peer units to directly impact patients of other units. To accommodate these possibilities, we develop two hierarchical network autocorrelation models that allow for direct and indirect peer effect pathways between hospitals when modeling individual outcomes of the patients cared for at the hospitals. A Bayesian approach is used for model estimation while a simulation study is used to assess the performance of the models and sensitivity of results to different prior distributions. We construct a United States New England region patient-sharing hospital network and apply our Bayesian hierarchical models to study the diffusion of robotic surgery and hospital peer effects in patient outcomes using a cohort of United States Medicare beneficiaries in 2016 and 2017. The comparative fit of models to the data is assessed using Deviance information criteria tailored to hierarchical models that include peer effects as latent variables.
Collapse
|
16
|
ElliQ, an AI-Driven Social Robot to Alleviate Loneliness: Progress and Lessons Learned. JAR LIFE 2024; 13:22-28. [PMID: 38449726 PMCID: PMC10917141 DOI: 10.14283/jarlife.2024.2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/02/2024] [Accepted: 02/20/2024] [Indexed: 03/08/2024]
Abstract
Background Loneliness is a significant issue in older adults and can increase the risk of morbidity and mortality. Objective To present the development of ElliQ, a proactive, AI-driven social robot with multiple social and health coaching functions specifically designed to address loneliness and support older people. Development/Implementation ElliQ, a consumer robot with a friendly appearance, uses voice, sounds, light, and buttons through a touch screen to facilitate conversation, music, video calls, well-being assessments, stress reduction, cognitive games, and health reminders. The robot was deployed by 15 government agencies in the USA. Initial experience suggests it is not only highly engaging for older people but may be able to improve their quality of life and reduce loneliness. In addition, the development of a weekly report that patients can share with their clinicians to allow better integration into routine care is described. Conclusion This paper describes the development and real-world implementation of this product innovation and discusses challenges encountered and future directions.
Collapse
|
17
|
Postoperative virtual reality for recovery after bariatric surgery: study protocol for a randomised clinical trial. BJA OPEN 2024; 9:100258. [PMID: 38333728 PMCID: PMC10851198 DOI: 10.1016/j.bjao.2024.100258] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Accepted: 01/09/2024] [Indexed: 02/10/2024]
Abstract
Background Enhanced Recovery After Surgery (ERAS) protocols for bariatric surgery improve clinical outcomes. However, the impact of ERAS protocols on patient satisfaction is unknown. Virtual reality has been implemented as an effective adjunct to standard analgesic regimens. This study seeks to find out if immersive virtual reality in the immediate postoperative period could improve the subjective quality of recovery and further reduce opioid requirements for bariatric surgery patients compared with ERAS care alone. Methods This is a single-centre, randomised clinical trial of patients recovering from laparoscopic bariatric surgery. Once in the post-anaesthesia care unit (PACU), participants will receive either an immersive virtual reality plus ERAS protocol or ERAS protocol alone. The primary outcome will be the Quality of Recovery-15 (QoR-15) score at PACU discharge. Secondary outcomes include PACU opioid requirements, length of PACU stay, PACU pain scores, QoR-15 score on postoperative day 1, hospital length of stay, opioid requirements, and opioid-related adverse effects until hospital discharge. Conclusions Positive findings from this study could introduce virtual reality as a non-pharmacological adjunct during PACU care that improves subjective recovery for patients undergoing bariatric surgery. Clinical trial registration NCT04754165.
Collapse
|
18
|
Association of Obstructive Sleep Apnea With Postoperative Delirium in Procedures of Moderate-to-High Complexity: A Hospital-Registry Study. Anesth Analg 2024; 138:626-634. [PMID: 36995964 DOI: 10.1213/ane.0000000000006425] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/31/2023]
Abstract
BACKGROUND Patients suffering from obstructive sleep apnea (OSA) experience chronic sleep disturbances and desaturation, factors that have been associated with postoperative delirium and that can be aggravated after anesthesia for complex procedures. We investigated whether OSA is associated with delirium after anesthesia, and whether this association is modified by procedural complexity. METHODS Hospitalized patients ≥60 years who underwent general anesthesia or procedural sedation for procedures of moderate-to-high complexity between 2009 and 2020 at a tertiary health care network in Massachusetts were included. The primary exposure was OSA, defined based on International Classification of Diseases ( Ninth/Tenth Revision, Clinical Modification ) ( ICD-9 / 10-CM ) diagnostic codes, structured nursing interviews, anesthesia alert notes, and a validated risk score (BOSTN [body mass index, observed apnea, snoring, tiredness, and neck circumference]). The primary end point was delirium within 7 days after the procedure. Multivariable logistic regression and effect modification analyses adjusted for patient demographics, comorbidities, and procedural factors were applied. RESULTS A total of 46,352 patients were included, of which 1694 patients (3.7%) developed delirium, 537 (3.2%) with OSA, and 1,157 (4.0%) without OSA. In adjusted analyses, OSA was not associated with postprocedural delirium in the overall cohort (adjusted odds ratio [OR adj ], 1.06; 95% confidence interval [CI], 0.94-1.20; P = .35). However, a high procedural complexity modified the primary association ( P value for interaction = .002). OSA patients had a higher risk of delirium after high-complexity procedures (≥40 work relative value units) such as cardiac (OR adj , 1.33; 95% CI, 1.08-1.64; P = .007, P value for interaction = .005) or thoracic surgery (OR adj , 1.89; 95% CI, 1.19-3.00; P = .007, P value for interaction = .009), but no increased risk after moderate complexity procedures, including general surgery (OR adj , 0.86; 95% CI, 0.55-1.35; P = .52). CONCLUSIONS Compared to non-OSA patients, a history of OSA is associated with a higher risk after high-complexity procedures such as cardiac or thoracic surgery but not after procedures of moderate complexity.
Collapse
|
19
|
Observation of D_{s}^{+}→η^{'}μ^{+}ν_{μ}, Precision Test of Lepton Flavor Universality with D_{s}^{+}→η^{(')}l^{+}ν_{l}, and First Measurements of D_{s}^{+}→η^{(')}μ^{+}ν_{μ} Decay Dynamics. PHYSICAL REVIEW LETTERS 2024; 132:091802. [PMID: 38489649 DOI: 10.1103/physrevlett.132.091802] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Revised: 01/25/2024] [Accepted: 01/26/2024] [Indexed: 03/17/2024]
Abstract
By analyzing 7.33 fb^{-1} of e^{+}e^{-} annihilation data collected at center-of-mass energies between 4.128 and 4.226 GeV with the BESIII detector, we report the observation of the semileptonic decay D_{s}^{+}→η^{'}μ^{+}ν_{μ}, with a statistical significance larger than 10σ, and the measurements of the D_{s}^{+}→ημ^{+}ν_{μ} and D_{s}^{+}→η^{'}μ^{+}ν_{μ} decay dynamics for the first time. The branching fractions of D_{s}^{+}→ημ^{+}ν_{μ} and D_{s}^{+}→η^{'}μ^{+}ν_{μ} are determined to be (2.235±0.051_{stat}±0.052_{syst})% and (0.801±0.055_{stat}±0.028_{syst})%, respectively, with precision improved by factors of 6.0 and 6.6 compared to the previous best measurements. Combined with the results for the decays D_{s}^{+}→ηe^{+}ν_{e} and D_{s}^{+}→η^{'}e^{+}ν_{e}, the ratios of the decay widths are examined both inclusively and in several ℓ^{+}ν_{ℓ} four-momentum transfer ranges. No evidence for lepton flavor universality violation is found within the current statistics. The products of the hadronic form factors f_{+,0}^{η^{(')}}(0) and the c→s Cabibbo-Kobayashi-Maskawa matrix element |V_{cs}| are determined. The results based on the two-parameter series expansion are f_{+,0}^{η}(0)|V_{cs}|=0.452±0.010_{stat}±0.007_{syst} and f_{+,0}^{η^{'}}(0)|V_{cs}|=0.504±0.037_{stat}±0.012_{syst}, which help to constrain present models on f_{+,0}^{η^{(')}}(0). The forward-backward asymmetries are determined to be ⟨A_{FB}^{η}⟩=-0.059±0.031_{stat}±0.005_{syst} and ⟨A_{FB}^{η^{'}}⟩=-0.064±0.079_{stat}±0.006_{syst} for the first time, which are consistent with the theoretical calculation.
Collapse
|
20
|
Adjustments of Ventilator Parameters during Operating Room-to-ICU Transition and 28-Day Mortality. Am J Respir Crit Care Med 2024; 209:553-562. [PMID: 38190707 DOI: 10.1164/rccm.202307-1168oc] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2023] [Accepted: 01/08/2024] [Indexed: 01/10/2024] Open
Abstract
Rationale: Lung-protective mechanical ventilation strategies have been proven beneficial in the operating room (OR) and the ICU. However, differential practices in ventilator management persist, often resulting in adjustments of ventilator parameters when transitioning patients from the OR to the ICU. Objectives: To characterize patterns of ventilator adjustments during the transition of mechanically ventilated surgical patients from the OR to the ICU and assess their impact on 28-day mortality. Methods: Hospital registry study including patients undergoing general anesthesia with continued, controlled mechanical ventilation in the ICU between 2008 and 2022. Ventilator parameters were assessed 1 hour before and 6 hours after the transition. Measurements and Main Results: Of 2,103 patients, 212 (10.1%) died within 28 days. Upon OR-to-ICU transition, VT and driving pressure decreased (-1.1 ml/kg predicted body weight [IQR, -2.0 to -0.2]; P < 0.001; and -4.3 cm H2O [-8.2 to -1.2]; P < 0.001). Concomitantly, respiratory rates increased (+5.0 breaths/min [2.0 to 7.5]; P < 0.001), resulting overall in slightly higher mechanical power (MP) in the ICU (+0.7 J/min [-1.9 to 3.0]; P < 0.001). In adjusted analysis, increases in MP were associated with a higher 28-day mortality rate (adjusted odds ratio, 1.10; 95% confidence interval, 1.06-1.14; P < 0.001; adjusted risk difference, 0.7%; 95% confidence interval, 0.4-1.0, both per 1 J/min). Conclusion: During transition of mechanically ventilated patients from the OR to the ICU, ventilator adjustments resulting in higher MP were associated with a greater risk of 28-day mortality.
Collapse
|
21
|
Determination of the Σ^{+} Timelike Electromagnetic Form Factors. PHYSICAL REVIEW LETTERS 2024; 132:081904. [PMID: 38457707 DOI: 10.1103/physrevlett.132.081904] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2023] [Revised: 11/24/2023] [Accepted: 01/12/2024] [Indexed: 03/10/2024]
Abstract
Based on data samples collected with the BESIII detector at the BEPCII collider, the process e^{+}e^{-}→Σ^{+}Σ[over ¯]^{-} is studied at center-of-mass energies sqrt[s]=2.3960, 2.6454, and 2.9000 GeV. Using a fully differential angular description of the final state particles, both the relative magnitude and phase information of the Σ^{+} electromagnetic form factors in the timelike region are extracted. The relative phase between the electric and magnetic form factors is determined to be sinΔΦ=-0.67±0.29(stat)±0.18(syst) at sqrt[s]=2.3960 GeV, ΔΦ=55°±19°(stat)±14°(syst) at sqrt[s]=2.6454 GeV, and 78°±22°(stat)±9°(syst) at sqrt[s]=2.9000 GeV. For the first time, the phase of the hyperon electromagnetic form factors is explored in a wide range of four-momentum transfer. The evolution of the phase along with four-momentum transfer is an important input for understanding its asymptotic behavior and the dynamics of baryons.
Collapse
|
22
|
Construction and validation of a predictive model of invasive adenocarcinoma in pure ground-glass nodules less than 2 cm in diameter. BMC Surg 2024; 24:56. [PMID: 38355554 PMCID: PMC10868041 DOI: 10.1186/s12893-024-02341-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2023] [Accepted: 02/01/2024] [Indexed: 02/16/2024] Open
Abstract
OBJECTIVES In this study, we aimed to develop a multiparameter prediction model to improve the diagnostic accuracy of invasive adenocarcinoma in pulmonary pure glass nodules. METHOD We included patients with pulmonary pure glass nodules who underwent lung resection and had a clear pathology between January 2020 and January 2022 at the Qilu Hospital of Shandong University. We collected data on the clinical characteristics of the patients as well as their preoperative biomarker results and computed tomography features. Thereafter, we performed univariate and multivariate logistic regression analyses to identify independent risk factors, which were then used to develop a prediction model and nomogram. We then evaluated the recognition ability of the model via receiver operating characteristic (ROC) curve analysis and assessed its calibration ability using the Hosmer-Lemeshow test and calibration curves. Further, to assess the clinical utility of the nomogram, we performed decision curve analysis. RESULT We included 563 patients, comprising 174 and 389 cases of invasive and non-invasive adenocarcinoma, respectively, and identified seven independent risk factors, namely, maximum tumor diameter, age, serum amyloid level, pleural effusion sign, bronchial sign, tumor location, and lobulation. The area under the ROC curve was 0.839 (95% CI: 0.798-0.879) for the training cohort and 0.782 (95% CI: 0.706-0.858) for the validation cohort, indicating a relatively high predictive accuracy for the nomogram. Calibration curves for the prediction model also showed good calibration for both cohorts, and decision curve analysis showed that the clinical prediction model has clinical utility. CONCLUSION The novel nomogram thus constructed for identifying invasive adenocarcinoma in patients with isolated pulmonary pure glass nodules exhibited excellent discriminatory power, calibration capacity, and clinical utility.
Collapse
|
23
|
[Analysis of the awareness rate and correlates of core information on tuberculosis prevention and control in elderly in Chinese]. ZHONGHUA LIU XING BING XUE ZA ZHI = ZHONGHUA LIUXINGBINGXUE ZAZHI 2024; 45:237-241. [PMID: 38413063 DOI: 10.3760/cma.j.cn112338-20230606-00351] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Subscribe] [Scholar Register] [Indexed: 02/29/2024]
Abstract
Objective: To understand the awareness and influencing factors of core information on tuberculosis prevention and control in the elderly population in China. Methods: The study included all participants aged ≥60 from the "13th Five-Year" National Tuberculosis Control Plan end-term assessment in 2020, with 13 706 valid questionnaires obtained. Multivariate logistic regression was used to analyze the influencing factors of the awareness rate of core information on tuberculosis prevention and control in the elderly. Results: The total awareness rate of core information on tuberculosis prevention and control in the elderly aged ≥60 was 78.4%, with the highest for "suspicious symptoms of pulmonary tuberculosis" (85.4%) and the lowest for "whether pulmonary tuberculosis can be cured" (65.3%). The complete awareness rate of core information on tuberculosis prevention and control in the elderly was 41.3%, and the proportion of those who received tuberculosis health education is 67.6%. Multivariate logistic regression analysis results showed that factors associated with low awareness of core information included females (OR=0.93, 95%CI: 0.86-1.00), ages 70- (OR=0.91, 95%CI: 0.84-0.98) and ≥80 (OR=0.77, 95%CI: 0.68-0.87) and minority ethnicity (OR=0.85, 95%CI: 0.74-0.99). Factors associated with high awareness of core information included educational levels of junior high school (OR=1.46, 95%CI: 1.34-1.58), high school (OR=1.62, 95%CI: 1.45-1.81), junior college (OR=1.37, 95%CI: 1.11-1.68), and an undergraduate degree or higher (OR=1.52, 95%CI: 1.09-2.11), and receiving tuberculosis health education (OR=2.13, 95%CI: 1.97-2.27). Conclusions: In 2020, the awareness rate of core information on tuberculosis prevention and control in Chinese older adults aged ≥60 was lower than the national planning target. Therefore, there should be an increased focus on health education about tuberculosis for elderly females, those aged ≥70, ethnic minorities, and those with lower education levels.
Collapse
|
24
|
Silencing of aryl hydrocarbon receptor repressor restrains Th17 cell immunity in autoimmune hepatitis. J Autoimmun 2024; 143:103162. [PMID: 38142533 PMCID: PMC10981568 DOI: 10.1016/j.jaut.2023.103162] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Revised: 11/20/2023] [Accepted: 12/12/2023] [Indexed: 12/26/2023]
Abstract
Th17-cells play a key role in the pathogenesis of autoimmune hepatitis (AIH). Dysregulation of Th17-cells in AIH is linked to defective response to aryl-hydrocarbon-receptor (AhR) activation. AhR modulates adaptive immunity and is regulated by aryl-hydrocarbon-receptor-repressor (AHRR), which inhibits AhR transcriptional activity. In this study, we investigated whether defective Th17-cell response to AhR derives from aberrant AHRR regulation in AIH. Th17-cells, obtained from the peripheral blood of AIH patients (n = 30) and healthy controls (n = 30) were exposed to AhR endogenous ligands, and their response assessed in the absence or presence of AHRR silencing. Therapeutic effects of AHRR blockade were tested in a model of Concanavalin-A (Con-A)-induced liver injury in humanized mice. AHRR was markedly upregulated in AIH Th17-cells, following exposure to l-kynurenine, an AhR endogenous ligand. In patients, silencing of AHRR boosted Th17-cell response to l-kynurenine, as reflected by increased levels of CYP1A1, the main gene controlled by AhR; and decreased IL17A expression. Blockade of AHRR limited the differentiation of naïve CD4-cells into Th17 lymphocytes; and modulated Th17-cell metabolic profile by increasing the levels of uridine via ATP depletion or pyrimidine salvage. Treatment with 2'-deoxy-2'-fluoro-d-arabinonucleic acid (FANA) oligonucleotides to silence human AHRR in vivo, reduced ALT levels, attenuated lymphocyte infiltration on histology, and heightened frequencies of regulatory immune subsets in NOD/scid/gamma mice, reconstituted with human CD4 cells, and exposed to Con-A. In conclusion, blockade of AHRR in AIH restores Th17-cell response to AHR, and limits Th17-cell differentiation through generation of uridine. In vivo, silencing of AHRR attenuates liver damage in NOD/scid/gamma mice. Blockade of AHRR might therefore represent a novel therapeutic strategy to modulate effector Th17-cell immunity and restore homeostasis in AIH.
Collapse
|
25
|
First Measurement of the Decay Asymmetry in the Pure W-Boson-Exchange Decay Λ_{c}^{+}→Ξ^{0}K^{+}. PHYSICAL REVIEW LETTERS 2024; 132:031801. [PMID: 38307076 DOI: 10.1103/physrevlett.132.031801] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Accepted: 11/30/2023] [Indexed: 02/04/2024]
Abstract
Based on 4.4 fb^{-1} of e^{+}e^{-} annihilation data collected at the center-of-mass energies between 4.60 and 4.70 GeV with the BESIII detector at the BEPCII collider, the pure W-boson-exchange decay Λ_{c}^{+}→Ξ^{0}K^{+} is studied with a full angular analysis. The corresponding decay asymmetry is measured for the first time to be α_{Ξ^{0}K^{+}}=0.01±0.16(stat)±0.03(syst). This result reflects the noninterference effect between the S- and P-wave amplitudes. The phase shift between S- and P-wave amplitudes has two solutions, which are δ_{p}-δ_{s}=-1.55±0.25(stat)±0.05(syst) rad or 1.59±0.25(stat)±0.05(syst) rad.
Collapse
|
26
|
High Mechanical Power and Driving Pressures are Associated With Postoperative Respiratory Failure Independent From Patients' Respiratory System Mechanics. Crit Care Med 2024; 52:68-79. [PMID: 37695139 DOI: 10.1097/ccm.0000000000006038] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/12/2023]
Abstract
OBJECTIVES High mechanical power and driving pressure (ΔP) have been associated with postoperative respiratory failure (PRF) and may be important parameters guiding mechanical ventilation. However, it remains unclear whether high mechanical power and ΔP merely reflect patients with poor respiratory system mechanics at risk of PRF. We investigated the effect of mechanical power and ΔP on PRF in cohorts after exact matching by patients' baseline respiratory system compliance. DESIGN Hospital registry study. SETTING Academic hospital in New England. PATIENTS Adult patients undergoing general anesthesia between 2008 and 2020. INTERVENTION None. MEASUREMENTS AND MAIN RESULTS The primary exposure was high (≥ 6.7 J/min, cohort median) versus low mechanical power and the key-secondary exposure was high (≥ 15.0 cm H 2 O) versus low ΔP. The primary endpoint was PRF (reintubation or unplanned noninvasive ventilation within seven days). Among 97,555 included patients, 4,030 (4.1%) developed PRF. In adjusted analyses, high intraoperative mechanical power and ΔP were associated with higher odds of PRF (adjusted odds ratio [aOR] 1.37 [95% CI, 1.25-1.50]; p < 0.001 and aOR 1.45 [95% CI, 1.31-1.60]; p < 0.001, respectively). There was large variability in applied ventilatory parameters, dependent on the anesthesia provider. This facilitated matching of 63,612 (mechanical power cohort) and 53,260 (ΔP cohort) patients, yielding identical baseline standardized respiratory system compliance (standardized difference [SDiff] = 0.00) with distinctly different mechanical power (9.4 [2.4] vs 4.9 [1.3] J/min; SDiff = -2.33) and ΔP (19.3 [4.1] vs 11.9 [2.1] cm H 2 O; SDiff = -2.27). After matching, high mechanical power and ΔP remained associated with higher risk of PRF (aOR 1.30 [95% CI, 1.17-1.45]; p < 0.001 and aOR 1.28 [95% CI, 1.12-1.46]; p < 0.001, respectively). CONCLUSIONS High mechanical power and ΔP are associated with PRF independent of patient's baseline respiratory system compliance. Our findings support utilization of these parameters for titrating mechanical ventilation in the operating room and ICU.
Collapse
|
27
|
Risk factors for mortality in patients with tuberculosis admitted to intensive care units. EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES 2024; 28:822-828. [PMID: 38305625 DOI: 10.26355/eurrev_202401_35083] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/03/2024]
Abstract
OBJECTIVE The purpose of this study is to investigate the mortality of patients with tuberculosis (TB) who need to be admitted to the intensive care unit (ICU) and to analyze the risk factors for mortality. PATIENTS AND METHODS A retrospective analysis was conducted to collect clinical data of patients with TB who were hospitalized in the ICU at Hebei Chest Hospital between 2015 and 2020. Subsequent to data collection, a rigorous statistical analysis was conducted. RESULTS A total of 99 patients with TB were admitted to the ICU of Hebei Chest Hospital from 2015 to 2020. After 28 days, 78 of the 99 eligible participants in this study died, while 21 survived. The mortality rate of patients with TB in the ICU was 78.79%. There was a significant difference in the length of stay in ICU, shock, drug, acute physiology, and chronic health evaluation (APACHE) II, procalcitonin, C-reactive protein, and albumin (p < 0.05). Further analysis indicated that the length of stay in the ICU, shock, APACHE II, and albumin were considered independent risk factors for mortality. CONCLUSIONS In China, the mortality rate of patients with TB requiring admission to the ICU is very high. In these patients, a prolonged ICU stay, a high APACHE II score, the onset of shock in the ICU, and a low albumin level have a significant impact on the risk of mortality.
Collapse
|
28
|
[The functional connection of Erythroferrone in iron and energy metabolism]. ZHONGHUA NEI KE ZA ZHI 2024; 63:121-125. [PMID: 38186129 DOI: 10.3760/cma.j.cn112138-20231024-00245] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/09/2024]
|
29
|
AI's deep dive into complex pediatric inguinal hernia issues: a challenge to traditional guidelines? Hernia 2023; 27:1587-1599. [PMID: 37843604 DOI: 10.1007/s10029-023-02900-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Accepted: 09/19/2023] [Indexed: 10/17/2023]
Abstract
OBJECTIVE This study utilized ChatGPT, an artificial intelligence program based on large language models, to explore controversial issues in pediatric inguinal hernia surgery and compare its responses with the guidelines of the European Association of Pediatric Surgeons (EUPSA). METHODS Six contentious issues raised by EUPSA were submitted to ChatGPT 4.0 for analysis, for which two independent responses were generated for each issue. These generated answers were subsequently compared with systematic reviews and guidelines. To ensure content accuracy and reliability, a content analysis was conducted, and expert evaluations were solicited for validation. Content analysis evaluated the consistency or discrepancy between ChatGPT 4.0's responses and the guidelines. An expert scoring method assess the quality, reliability, and applicability of responses. The TF-IDF model tested the stability and consistency of the two responses. RESULTS The responses generated by ChatGPT 4.0 were mostly consistent with the guidelines. However, some differences and contradictions were noted. The average quality score was 3.33, reliability score was 2.75, and applicability score was 3.46 (out of 5). The average similarity between the two responses was 0.72 (out of 1), Content analysis and expert ratings yielded consistent conclusions, enhancing the credibility of our research. CONCLUSION ChatGPT can provide valuable responses to clinical questions, but it has limitations and requires further improvement. It is recommended to combine ChatGPT with other reliable data sources to improve clinical practice and decision-making.
Collapse
|
30
|
Inflammatory subphenotypes in patients at risk of ARDS: evidence from the LIPS-A trial. Intensive Care Med 2023; 49:1499-1507. [PMID: 37906258 DOI: 10.1007/s00134-023-07244-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Accepted: 09/23/2023] [Indexed: 11/02/2023]
Abstract
PURPOSE Latent class analysis (LCA) has identified hyper- and non-hyper-inflammatory subphenotypes in patients with acute respiratory distress syndrome (ARDS). It is unknown how early inflammatory subphenotypes can be identified in patients at risk of ARDS. We aimed to test for inflammatory subphenotypes upon presentation to the emergency department. METHODS LIPS-A was a trial of aspirin to prevent ARDS in at-risk patients presenting to the emergency department. In this secondary analysis, we performed LCA using clinical, blood test, and biomarker variables. RESULTS Among 376 (96.4%) patients from the LIPS-A trial, two classes were identified upon presentation to the emergency department (day 0): 72 (19.1%) patients demonstrated characteristics of a hyper-inflammatory and 304 (80.9%) of a non-hyper-inflammatory subphenotype. 15.3% of patients in the hyper- and 8.2% in the non-hyper-inflammatory class developed ARDS (p = 0.07). Patients in the hyper-inflammatory class had fewer ventilator-free days (median [interquartile range, IQR] 28[23-28] versus 28[27-28]; p = 0.010), longer intensive care unit (3[2-6] versus 0[0-3] days; p < 0.001) and hospital (9[6-18] versus 5[3-9] days; p < 0.001) length of stay, and higher 1-year mortality (34.7% versus 20%; p = 0.008). Subphenotypes were identified on day 1 and 4 in a subgroup with available data (n = 244). 77.9% of patients remained in their baseline class throughout day 4. Patients with a hyper-inflammatory subphenotype throughout the study period (n = 22) were at higher risk of ARDS (36.4% versus 10.4%; p = 0.003). CONCLUSION Hyper- and non-hyper-inflammatory subphenotypes may precede ARDS development, remain identifiable over time, and can be identified upon presentation to the emergency department. A hyper-inflammatory subphenotype predicts worse outcomes.
Collapse
|
31
|
[Effect of recombinant human thrombin for hemostasis in liver resection: a randomized controlled phase Ⅲ clinical trial]. ZHONGHUA YI XUE ZA ZHI 2023; 103:3416-3423. [PMID: 37963740 DOI: 10.3760/cma.j.cn112137-20230911-00438] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 11/16/2023]
Abstract
Objective: To evaluate the hemostatic efficacy, safety and immunogenicity of recombinant human thrombin in the treatment of liver wounds that still ooze after conventional surgical hemostasis. Methods: A multicenter, stratified randomized, double-blind, placebo-controlled phase Ⅲ trial with a planned enrollment of 510 subjects at 33 centers, with a 2∶1 randomization to the thrombin group versus the placebo group. An interim analysis will be conducted after approximately 70% of the subjects have completed the observation period. The primary efficacy endpoint was the rate of hemostasis within 6 minutes at the point of bleeding that could be evaluated. Safety analysis was performed one month after surgery, and the positive rates of anti-drug antibody (ADA) and neutralizing antibody were evaluated. Results: At the interim analysis, a total of 348 subjects had been randomized and received the study drug (215 were male and 133 were female). They were aged 19-69 (52.9±10.9)years. Among them, 232 were in the thrombin group and 116 were in the placebo group, with balanced and comparable demographics and baseline characteristics between the two groups. The hemostasis rate at 6 minutes was 71.6% (95%CI:65.75%-77.36%) in the thrombin group and 44.0% (95%CI: 34.93%-53.00%) in the placebo group, respectively (P<0.001). No grade≥3 drug-related adverse events and no drug-related deaths were reported from the study.No recombinant human thrombin-induced immunologically-enhanced ADA or immunologically-induced ADA was detected after topical use in subjects. Conclusion: Recombinant human thrombin has shown significant hemostatic efficacy and good safety in controlling bleeding during liver resection surgery, while also demonstrating low immunogenicity characteristics.
Collapse
|
32
|
Test of CP Symmetry in Hyperon to Neutron Decays. PHYSICAL REVIEW LETTERS 2023; 131:191802. [PMID: 38000397 DOI: 10.1103/physrevlett.131.191802] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2023] [Accepted: 10/03/2023] [Indexed: 11/26/2023]
Abstract
The quantum entangled J/ψ→Σ^{+}Σ[over ¯]^{-} pairs from (1.0087±0.0044)×10^{10} J/ψ events taken by the BESIII detector are used to study the nonleptonic two-body weak decays Σ^{+}→nπ^{+} and Σ[over ¯]^{-}→n[over ¯]π^{-}. The CP-odd weak decay parameters of the decays Σ^{+}→nπ^{+} (α_{+}) and Σ[over ¯]^{-}→n[over ¯]π^{-} (α[over ¯]_{-}) are determined to be 0.0481±0.0031_{stat}±0.0019_{syst} and -0.0565±0.0047_{stat}±0.0022_{syst}, respectively. The decay parameter α[over ¯]_{-} is measured for the first time, and the accuracy of α_{+} is improved by a factor of 4 compared to the previous results. The simultaneously determined decay parameters allow the first precision CP symmetry test for any hyperon decay with a neutron in the final state with the measurement of A_{CP}=(α_{+}+α[over ¯]_{-})/(α_{+}-α[over ¯]_{-})=-0.080±0.052_{stat}±0.028_{syst}. Assuming CP conservation, the average decay parameter is determined as ⟨α_{+}⟩=(α_{+}-α[over ¯]_{-})/2=-0.0506±0.0026_{stat}±0.0019_{syst}, while the ratios α_{+}/α_{0} and α[over ¯]_{-}/α[over ¯]_{0} are -0.0490±0.0032_{stat}±0.0021_{syst} and -0.0571±0.0053_{stat}±0.0032_{syst}, where α_{0} and α[over ¯]_{0} are the decay parameters of the decays Σ^{+}→pπ^{0} and Σ[over ¯]^{-}→p[over ¯]π^{0}, respectively.
Collapse
|
33
|
Measurement of Energy-Dependent Pair-Production Cross Section and Electromagnetic Form Factors of a Charmed Baryon. PHYSICAL REVIEW LETTERS 2023; 131:191901. [PMID: 38000396 DOI: 10.1103/physrevlett.131.191901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Revised: 08/29/2023] [Accepted: 09/15/2023] [Indexed: 11/26/2023]
Abstract
We study the process e^{+}e^{-}→Λ_{c}^{+}Λ[over ¯]_{c}^{-} at twelve center-of-mass energies from 4.6119 to 4.9509 GeV using data samples collected by the BESIII detector at the BEPCII collider. The Born cross sections and effective form factors (|G_{eff}|) are determined with unprecedented precision after combining the single and double-tag methods based on the decay process Λ_{c}^{+}→pK^{-}π^{+}. Flat cross sections around 4.63 GeV are obtained and no indication of the resonant structure Y(4630), as reported by Belle, is found. In addition, no oscillatory behavior is discerned in the |G_{eff}| energy dependence of Λ_{c}^{+}, in contrast to what is seen for the proton and neutron cases. Analyzing the cross section together with the polar-angle distribution of the Λ_{c}^{+} baryon at each energy point, the moduli of electric and magnetic form factors (|G_{E}| and |G_{M}|) are extracted and separated. For the first time, the energy dependence of the form factor ratio |G_{E}/G_{M}| is observed, which can be well described by an oscillatory function.
Collapse
|
34
|
[Efficacy and prognosis of infant kidney transplantation]. ZHONGHUA YI XUE ZA ZHI 2023; 103:3010-3016. [PMID: 37587680 DOI: 10.3760/cma.j.cn112137-20230306-00338] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 08/18/2023]
Abstract
Objective: To analyze the effect and prognosis of infant kidney transplantation. Methods: Clinical data of 37 cases of infant kidney transplantation under 3 years old in Tongji Hospital Affiliated to Tongji Medical College of Huazhong University of Science and Technology from June 1, 2017 to July 31, 2022 were retrospectively collected. These 37 cases included 31 primary kidney transplantation and 6 secondary kidney transplantation. Kaplan-Meier method was used to draw the survival curve of the transplanted kidney and the recipient, and the prognosis and complications were analyzed. Median follow-up was 18 months (range: 6-66 months). Results: The recipients were 20 males and 17 females, with a median age of 16 months (range: 2 months, 26 days to 36 months) and a median weight of 8 kg (range: 3.2 to 14.0 kg). The youngest child was only 2 months, 26 days old, and weighed only 3.2 kg. The most common primary disease of recipients was congenital nephrotic syndrome (13 cases, 41.9%). Intra-abdominal transplantation occurred in 19 cases (51.3%) and intra-iliac fossa transplantation occurred in the remaining 18 cases (48.6%). Postoperative renal function recovery was delayed in 7 cases (18.9%), and thrombosis caused renal function loss in 5 cases (13.5%), of which 4 cases received second renal transplantation and were successful. During the follow-up period, there were 11 cases of acute rejection (29.7%) and 6 cases of CMV pneumonia (16.2%). The estimated glomerular filtration rate 1 year after transplantation was higher than that 1 month after surgery [(101.9±22.1) vs (71.1±25.6) ml/(min·1.73m2), P<0.001], and remained constant 2 years after transplantation. Both the 1-year and 2-year survival rates of the transplanted kidney were 85.3%, and both the 1-year and 2-year survival rates of the recipients were 96.8%. Conclusion: Although the implementation of infant kidney transplantation is difficult, it can still achieve relatively satisfactory efficacy and prognosis.
Collapse
|
35
|
Determination of Spin-Parity Quantum Numbers for the Narrow Structure near the pΛ[over ¯] Threshold in e^{+}e^{-}→pK^{-}Λ[over ¯]+c.c. PHYSICAL REVIEW LETTERS 2023; 131:151901. [PMID: 37897776 DOI: 10.1103/physrevlett.131.151901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 08/22/2023] [Accepted: 09/15/2023] [Indexed: 10/30/2023]
Abstract
A narrow structure in the pΛ[over ¯] system near the mass threshold, named as X(2085), is observed in the process e^{+}e^{-}→pK^{-}Λ[over ¯] with a statistical significance greater than 20σ. Its spin and parity are determined for the first time to be J^{P}=1^{+} in an amplitude analysis, with a statistical significance greater than 5σ over other quantum numbers (0^{-},1^{-} and 2^{+}). The pole positions of X(2085) are measured to be M_{pole}=(2084_{-2}^{+4}±9) MeV and Γ_{pole}=(58_{-3}^{+4}±25) MeV, where the first uncertainties are statistical and the second ones are systematic. The analysis is based on the study of the process e^{+}e^{-}→pK^{-}Λ[over ¯] and uses the data samples collected with the BESIII detector at the center-of-mass energies sqrt[s]=4.008, 4.178, 4.226, 4.258, 4.416, and 4.682 GeV with a total integrated luminosity of 8.35 fb^{-1}.
Collapse
|
36
|
Precise Measurement of the e^{+}e^{-}→D_{s}^{*+}D_{s}^{*-} Cross Sections at Center-of-Mass Energies from Threshold to 4.95 GeV. PHYSICAL REVIEW LETTERS 2023; 131:151903. [PMID: 37897771 DOI: 10.1103/physrevlett.131.151903] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Revised: 08/16/2023] [Accepted: 08/29/2023] [Indexed: 10/30/2023]
Abstract
The process e^{+}e^{-}→D_{s}^{*+}D_{s}^{*-} is studied with a semi-inclusive method using data samples at center-of-mass energies from threshold to 4.95 GeV collected with the BESIII detector operating at the Beijing Electron Positron Collider. The Born cross sections of the process are measured for the first time with high precision in this energy region. Two resonance structures are observed in the energy-dependent cross sections around 4.2 and 4.4 GeV. By fitting the cross sections with a coherent sum of three Breit-Wigner amplitudes and one phase-space amplitude, the two significant structures are assigned masses of (4186.8±8.7±30) and (4414.6±3.4±6.1) MeV/c^{2}, widths of (55±15±53) and (122.5±7.5±8.1) MeV, where the first errors are statistical and the second ones are systematic. The inclusion of a third Breit-Wigner amplitude is necessary to describe a structure around 4.79 GeV.
Collapse
|
37
|
First Experimental Study of the Purely Leptonic Decay D_{s}^{*+}→e^{+}ν_{e}. PHYSICAL REVIEW LETTERS 2023; 131:141802. [PMID: 37862669 DOI: 10.1103/physrevlett.131.141802] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 07/25/2023] [Accepted: 09/05/2023] [Indexed: 10/22/2023]
Abstract
Using 7.33 fb^{-1} of e^{+}e^{-} collision data taken with the BESIII detector at the BEPCII collider, we report the first experimental study of the purely leptonic decay D_{s}^{*+}→e^{+}ν_{e}. Our data contain a signal of this decay with a statistical significance of 2.9σ. The branching fraction of D_{s}^{*+}→e^{+}ν_{e} is measured to be (2.1_{-0.9_{stat}}^{+1.2}±0.2_{syst})×10^{-5}, corresponding to an upper limit of 4.0×10^{-5} at the 90% confidence level. Taking the total width of the D_{s}^{*+} [(0.070±0.028) keV] predicted with the radiative D_{s}^{*+} decay from the lattice QCD calculation as input, the decay constant of the D_{s}^{*+} is determined to be f_{D_{s}^{*+}}=(214_{-46_{stat}}^{+61}±44_{syst}) MeV, corresponding to an upper limit of 354 MeV at the 90% confidence level.
Collapse
|
38
|
Intensity of one-lung ventilation and postoperative respiratory failure: A hospital registry study. Anaesth Crit Care Pain Med 2023; 42:101250. [PMID: 37236317 DOI: 10.1016/j.accpm.2023.101250] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Revised: 05/10/2023] [Accepted: 05/18/2023] [Indexed: 05/28/2023]
Abstract
BACKGROUND Studies linked a high intensity of mechanical ventilation, measured as high mechanical power (MP) to postoperative respiratory failure (PRF) in the setting of two-lung ventilation. We investigated whether a higher MP during one-lung ventilation (OLV) is associated with PRF. METHODS In this registry-based study, adult patients who underwent general anesthesia with OLV for thoracic surgeries between 2006 and 2020 at a New England tertiary healthcare network were included. The association between MP during OLV and PRF (emergency non-invasive ventilation or reintubation within seven days) was assessed in a cohort weighted through a generalized propensity score conditional on a priori defined preoperative and intraoperative factors. Dominance of components of MP and intensity of OLV versus two-lung ventilation in predicting PRF was investigated. RESULTS Out of 878 included patients, 106 (12.1%) developed PRF. The median (IQR) MP during OLV was 9.8 J/min (7.5-11.8) and 8.3 J/min (6.6-10.2) in patients with and without PRF respectively. A higher MP during OLV was associated with PRF (ORadj 1.22 per 1 J/min increase; 95%CI 1.13-1.31; p < 0.001) and characterized by a U-shaped dose-response curve, with the lowest probability of PRF (7.5%) at 6.4 J/min. Dominance analysis of PRF predictors showed a stronger contribution of driving pressure over respiratory rate and tidal volume, the dynamic over the static component of MP, and MP during OLV over two-lung ventilation (contribution to Pseudo-R2: 0.017, 0.021, and 0.036, respectively). CONCLUSION A higher intensity of OLV, mainly driven by driving pressure, is dose-dependently associated with PRF and might constitute a target for mechanical ventilation.
Collapse
|
39
|
Search for Λ[over ¯]-Λ Baryon-Number-Violating Oscillations in the Decay J/ψ→pK^{-}Λ[over ¯]+c.c. PHYSICAL REVIEW LETTERS 2023; 131:121801. [PMID: 37802947 DOI: 10.1103/physrevlett.131.121801] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/08/2023] [Revised: 08/14/2023] [Accepted: 08/29/2023] [Indexed: 10/08/2023]
Abstract
We report on the first search for Λ[over ¯]-Λ oscillations in the decay J/ψ→pK^{-}Λ[over ¯]+c.c. by analyzing 1.31×10^{9} J/ψ events accumulated with the BESIII detector at the BEPCII collider. The J/ψ events are produced using e^{+}e^{-} collisions at a center of mass energy sqrt[s]=3.097 GeV. No evidence for hyperon oscillations is observed. The upper limit for the oscillation rate of Λ[over ¯] to Λ hyperons is determined to be P(Λ)=[B(J/ψ→pK^{-}Λ+c.c.)/B(J/ψ→pK^{-}Λ[over ¯]+c.c.)]<4.4×10^{-6} corresponding to an oscillation parameter δm_{ΛΛ[over ¯]} of less than 3.8×10^{-18} GeV at the 90% confidence level.
Collapse
|
40
|
[Comparison of clinical effects of endoscopic thyroidectomy using the modified gasless transsubclavian approach and traditional open surgery for cN0 unilateral papillary thyroid carcinoma]. ZHONGHUA WAI KE ZA ZHI [CHINESE JOURNAL OF SURGERY] 2023; 61:807-811. [PMID: 37491175 DOI: 10.3760/cma.j.cn112139-20230208-00056] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 07/27/2023]
Abstract
Objective: To compare the clinical effects of endoscopic thyroidectomy using a modified gasless transsubclavian approach and the traditional neck approach for unilateral papillary thyroid carcinoma (cN0). Methods: The clinical data of 135 patients with cN0 papillary thyroid carcinoma who underwent unilateral thyroidectomy in the Department of Thyroid Surgery, the First Hospital of Jilin University from October 2020 to November 2022 were retrospectively analyzed. There were 37 males and 98 females, aging (43.2±8.8) years (range: 21 to 59 years). There were 51 cases using the modified gasless transsubclavian approach (TS group) and 84 cases using the traditional neck approach (TN group). Comparative analyses were performed between the operative results of the 2 groups by t-test, Wilcoxon rank sum test, and χ2 test. Results: All endoscopic operations were successfully completed without conversion to the traditional neck approach. Compared to the TN group, the TS group had a longer operation time (M(IQR)) (73.5 (22.5) minutes vs. 90.0 (30.0) minutes, Z=-5.831, P<0.01), more postoperative drainage (60 (25) ml vs. 95 (45) ml, Z=-6.275, P<0.01), higher hospitalization costs (22 687 (3 488) yuan vs. 26 652 (2 431) yuan, Z=-6.944, P<0.01), and a higher rate of parathyroid autotransplantation (15.5% (13/84) vs. 60.8% (31/51), χ2=29.651, P<0.01). There was no significant difference in the total exposure rate of the central compartment, postoperative hospitalization time, the number of dissected lymph nodes, the number of metastatic lymph nodes, C-reactive protein ratio before and after operation, and preoperative and postoperative parathyroid hormone (all P>0.05). Conclusion: Endoscopic thyroidectomy using the modified gasless transsubclavian approach is safe for cN0 papillary thyroid carcinoma, with longer operating time, more postoperative drainage, higher hospitalization costs, and more difficulty in preserving the inferior parathyroid gland in situ compared to traditional open surgery.
Collapse
|
41
|
[Preliminary experience of transcatheter pulmonary valve replacement using domestic balloon-expandable valve]. ZHONGHUA XIN XUE GUAN BING ZA ZHI 2023; 51:825-831. [PMID: 37583330 DOI: 10.3760/cma.j.cn112148-20230608-00336] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Subscribe] [Scholar Register] [Indexed: 08/17/2023]
Abstract
Objectives: To evaluate the feasibility and preliminary clinical results of transcatheter pulmonary valve replacement (TPVR) with the domestically-produced balloon-expandable Prizvalve system. Methods: This is a prospective single-center observational study. Patients with postoperative right ventricular outflow tract (RVOT) dysfunction, who were admitted to West China Hospital of Sichuan University from September 2021 to March 2023 and deemed anatomically suitable for TPVR with balloon-expandable valve, were included. Clinical, imaging, procedural and follow-up data were analyzed. The immediate procedural results were evaluated by clinical implant success rate, which is defined as successful valve implantation with echocardiography-assessed pulmonary regurgitation
Collapse
|
42
|
Development and validation of a multiphase CT radiomics nomogram for the preoperative prediction of lymphovascular invasion in patients with gastric cancer. Clin Radiol 2023; 78:e552-e559. [PMID: 37117048 DOI: 10.1016/j.crad.2023.03.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Revised: 03/13/2023] [Accepted: 03/22/2023] [Indexed: 04/30/2023]
Abstract
AIM To develop a nomogram to predict lymphovascular invasion (LVI) in gastric cancer by integrating multiphase computed tomography (CT) radiomics and clinical risk factors. MATERIALS AND METHODS One hundred and seventy-two gastric cancer patients (121 training and 51 validation) with preoperative contrast-enhanced CT images and clinicopathological data were collected retrospectively. The clinical risk factors were selected by univariate and multivariate regression analysis. Radiomic features were extracted and selected from the arterial phase (AP), venous phase (VP), and delayed phase (DP) CT images of each patient. Clinical risk factors, radiomic features, and integration of both were used to develop the clinical model, radiomic models, and nomogram, respectively. RESULTS Radiomic features from AP (n=6), VP (n=6), DP (n=7) CT images and three selected clinical risk factors were used for model development. The nomogram showed better performance than the AP, VP, DP, and clinical models in the training and validation datasets, providing areas under the curves (AUCs) of 0.890 (95% CI: 0.820-0.940) and 0.885 (95% CI:0.765-0.957), respectively. All models indicated good calibration, and decision curve analysis proved that the net benefit of the nomogram was superior to that of the clinical and radiomic models throughout the vast majority of the threshold probabilities. CONCLUSIONS The nomogram integrating multiphase CT radiomics and clinical risk factors showed favourable performance in predicting LVI of gastric cancer, which may benefit clinical practice.
Collapse
|
43
|
Super-resolution of magnetic systems using deep learning. Sci Rep 2023; 13:11526. [PMID: 37460591 DOI: 10.1038/s41598-023-38335-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2023] [Accepted: 07/06/2023] [Indexed: 07/20/2023] Open
Abstract
We construct a deep neural network to enhance the resolution of spin structure images formed by spontaneous symmetry breaking in the magnetic systems. Through the deep neural network, an image is expanded to a super-resolution image and reduced to the original image size to be fitted with the input feed image. The network does not require ground truth images in the training process. Therefore, it can be applied when low-resolution images are provided as training datasets, while high-resolution images are not obtainable due to the intrinsic limitation of microscope techniques. To show the usefulness of the network, we train the network with two types of simulated magnetic structure images; one is from self-organized maze patterns made of chiral magnetic structures, and the other is from magnetic domains separated by walls that are topological defects of the system. The network successfully generates high-resolution images highly correlated with the exact solutions in both cases. To investigate the effectiveness and the differences between datasets, we study the network's noise tolerance and compare the networks' reliabilities. The network is applied with experimental data obtained by magneto-optical Kerr effect microscopy and spin-polarized low-energy electron microscopy.
Collapse
|
44
|
Association Between Intraoperative Dexamethasone and Postoperative Mortality in Patients Undergoing Oncologic Surgery: A Multicentric Cohort Study. Ann Surg 2023; 278:e105-e114. [PMID: 35837889 DOI: 10.1097/sla.0000000000005526] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE We examined the effects of dexamethasone on postoperative mortality, recurrence-free survival, and side effects in patients undergoing oncologic operations. BACKGROUND Dexamethasone prevents nausea and vomiting after anesthesia and may affect cancer proliferation. METHODS A total of 30,561 adult patients undergoing solid cancer resection between 2005 and 2020 were included. Multivariable logistic regression was applied to investigate the effect of dexamethasone on 1-year mortality and recurrence-free survival. Effect modification by the cancer's potential for immunogenicity, defined as a recommendation for checkpoint inhibitor therapy based on the National Comprehensive Cancer Network guidelines, was investigated through interaction term analysis. Key safety endpoints were dexamethasone-associated risk of hyperglycemia >180 mg/dL within 24 hours and surgical site infections within 30 days after surgery. RESULTS Dexamethasone was administered to 38.2% (11,666/30,561) of patients (6.5±2.3 mg). Overall, 3.2% (n=980/30,561) died and 15.4% (n=4718/30,561) experienced cancer recurrence within 1 year of the operation. Dexamethasone was associated with a -0.6% (95% confidence interval: -1.1, -0.2, P =0.007) 1-year mortality risk reduction [adjusted odds ratio (OR adj ): 0.79 (0.67, 0.94), P =0.009; hazard ratio=0.82 (0.69, 0.96), P =0.016] and higher odds of recurrence-free survival [OR adj : 1.28 (1.18, 1.39), P <0.001]. This effect was only present in patients with solid cancers who were defined as not to respond to checkpoint inhibitor therapy [OR adj : 0.70 (0.57, 0.87), P =0.001 vs OR adj : 1.13 (0.85, 1.50), P =0.40]. A high (>0.09 mg/kg) dose of dexamethasone increased the risk of postoperative hyperglycemia [OR adj : 1.55 (1.32, 1.82), P <0.001], but not for surgical site infections [OR adj : 0.84 (0.42, 1.71), P =0.63]. CONCLUSIONS Dexamethasone is associated with decreased 1-year mortality and cancer recurrence in patients undergoing surgical resection of cancers that are not candidates for immune modulators. Dexamethasone increased the risk of postoperative hyperglycemia, however, no increase in surgical site infections was identified.
Collapse
|
45
|
[Feasibility and safety of transseptal transcatheter mitral valve replacement for severe mitral regurgitation]. ZHONGHUA YI XUE ZA ZHI 2023; 103:1849-1854. [PMID: 37357191 DOI: 10.3760/cma.j.cn112137-20221109-02359] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Subscribe] [Scholar Register] [Indexed: 06/27/2023]
Abstract
A prospective, single-center, single-arm, and open-design study was performed to evaluate the feasibility and safety of transseptal transcatheter mitral valve replacement in the treatment of severe mitral regurgitation. Patients with symptomatic moderate-severe or severe mitral regurgitation at high-surgical risk and anatomically appropriate for the HighLife transseptal mitral valve replacement (TSMVR) system in West China Hospital, Sichuan University from December 2021 to August 2022 were enrolled. Four patients (1 male and 3 females) with severe mitral regurgitation were included, with a median age of 68.5 (64.0-77.0) years and a median Society of Thoracic Surgeons (STS) score of 8.1% (6.4%-8.9%). Technical success was achieved in all the patients. There was no residual mitral regurgitation, paravalvular leakage, or left ventricular outflow tract obstruction. Three major cardiovascular and cerebrovascular adverse events occurred within 30 days after the procedure, including ventricular tachycardia, iatrogenic atrial septal defect closure, and heart failure readmission. The current study preliminarily demonstrates that transcatheter mitral valve replacement using the HighLife system via the transseptal approach for severe mitral regurgitation is feasible and relatively safe.
Collapse
|
46
|
First Study of Reaction Ξ^{0}n→Ξ^{-}p Using Ξ^{0}-Nucleus Scattering at an Electron-Positron Collider. PHYSICAL REVIEW LETTERS 2023; 130:251902. [PMID: 37418739 DOI: 10.1103/physrevlett.130.251902] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/27/2023] [Revised: 05/20/2023] [Accepted: 05/25/2023] [Indexed: 07/09/2023]
Abstract
Using (1.0087±0.0044)×10^{10} J/ψ events collected with the BESIII detector at the BEPCII storage ring, the process Ξ^{0}n→Ξ^{-}p is studied, where the Ξ^{0} baryon is produced in the process J/ψ→Ξ^{0}Ξ[over ¯]^{0} and the neutron is a component of the ^{9}Be, ^{12}C, and ^{197}Au nuclei in the beam pipe. A clear signal is observed with a statistical significance of 7.1σ. The cross section of the reaction Ξ^{0}+^{9}Be→Ξ^{-}+p+^{8}Be is determined to be σ(Ξ^{0}+^{9}Be→Ξ^{-}+p+^{8}Be)=(22.1±5.3_{stat}±4.5_{sys}) mb at the Ξ^{0} momentum of 0.818 GeV/c, where the first uncertainty is statistical and the second is systematic. No significant H-dibaryon signal is observed in the Ξ^{-}p final state. This is the first study of hyperon-nucleon interactions in electron-positron collisions and opens up a new direction for such research.
Collapse
|
47
|
Measurements of Normalized Differential Cross Sections of Inclusive π^{0} and K_{S}^{0} Production in e^{+}e^{-} Annihilation at Energies from 2.2324 to 3.6710 GeV. PHYSICAL REVIEW LETTERS 2023; 130:231901. [PMID: 37354421 DOI: 10.1103/physrevlett.130.231901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Revised: 03/22/2023] [Accepted: 04/03/2023] [Indexed: 06/26/2023]
Abstract
Based on electron positron collision data collected with the BESIII detector operating at the BEPCII storage rings, the differential cross sections of inclusive π^{0} and K_{S}^{0} production as a function of hadron momentum, normalized by the total cross section of the e^{+}e^{-}→hadrons process, are measured at six center-of-mass energies from 2.2324 to 3.6710 GeV. Our results, which cover a relative hadron energy range from 0.1 to 0.9, significantly deviate from several theoretical calculations based on existing fragmentation functions.
Collapse
|
48
|
PD-1 Carried on Small Extracellular Vesicles Leads to OSCC Metastasis. J Dent Res 2023:220345231165209. [PMID: 37246810 DOI: 10.1177/00220345231165209] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/30/2023] Open
Abstract
Immune checkpoint molecule PD-1, expressed on the cell surface, impairs antigen-driven activation of T cells and thus plays a critical role in tumorigenesis, progression, and the poor prognosis of oral squamous cell carcinoma (OSCC). In addition, increasing evidence indicates that PD-1 carried on small extracellular vesicles (sEVs) also mediates tumor immunity, although their contributions to OSCC are yet unclear. Here, we investigated the biological functions of sEV PD-1 in patients with OSCC. The cell cycle, proliferation, apoptosis, migration, and invasion of CAL27 cell lines treated with or without sEV PD-1 were examined in vitro. We performed mass spectrometry to investigate the underlying biological process, combined with an immunohistochemical study of SCC7-bearing mice models and OSCC patient samples. In vitro data demonstrated that sEV PD-1 induced senescence and subsequent epithelial-mesenchymal transition (EMT) in CAL27 cells by ligating with tumor cell surface PD-L1 and activating the p38 mitogen-activated protein kinase (MAPK) pathway. Comprehensive immunohistochemical analysis of the xenograft mice models and OSCC patient samples revealed a very close correlation between the level of circulating sEV PD-1 and lymph node metastasis. These results demonstrate that circulating sEV PD-1 triggers senescence-initiated EMT in a PD-L1-p38 MAPK-dependent manner, contributing to tumor metastasis. It also suggests that the inhibition of sEV PD-1 may be a promising therapeutic target for the treatment of OSCC.
Collapse
|
49
|
Precision Measurement of the Decay Σ^{+}→pγ in the Process J/ψ→Σ^{+}Σ[over ¯]^{-}. PHYSICAL REVIEW LETTERS 2023; 130:211901. [PMID: 37295102 DOI: 10.1103/physrevlett.130.211901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Revised: 03/29/2023] [Accepted: 05/08/2023] [Indexed: 06/12/2023]
Abstract
Using (10 087±44)×10^{6} J/ψ events collected with the BESIII detector, the radiative hyperon decay Σ^{+}→pγ is studied at an electron-positron collider experiment for the first time. The absolute branching fraction is measured to be (0.996±0.021_{stat}±0.018_{syst})×10^{-3}, which is lower than its world average value by 4.2 standard deviations. Its decay asymmetry parameter is determined to be -0.652±0.056_{stat}±0.020_{syst}. The branching fraction and decay asymmetry parameter are the most precise to date, and the accuracies are improved by 78% and 34%, respectively.
Collapse
|
50
|
LncRNA FOXD2-AS1 facilitates the progression of hepatocellular carcinoma by regulating TWIST1. EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES 2023; 27:4536-4543. [PMID: 37259735 DOI: 10.26355/eurrev_202305_32460] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
OBJECTIVE The study aimed at elucidating the role of FOXD2-AS1 in facilitating the malignant progression of hepatocellular carcinoma (HCC) by regulating TWIST1. PATIENTS AND METHODS Relative levels of FOXD2-AS1 and TWIST1 in HCC tissues classified by tumor size and tumor node metastasis (TNM) staging were detected by quantitative Real-Time Polymerase Chain Reaction (qRT-PCR). The Kaplan-Meier method was applied to assess the prognostic potential of FOXD2-AS1 in HCC patients, followed by survival rate comparison using a log-rank test. After the knockdown of FOXD2-AS1 in HepG2 cells, the viability and migratory abilities were examined by Cell Counting Kit-8 (CCK-8) and transwell assay, respectively. The subcellular distribution of FOXD2-AS1 was detected. Finally, the involvement of TWIST1 in the regulation of HCC cell functions influenced by FOXD2-AS1 was explored. RESULTS FOXD2-AS1 was upregulated in HCC tissues, especially large tumor size or stage III-IV cases. High levels of FOXD2-AS1 predicted poor prognosis in HCC patients. FOXD2-AS1 was mainly distributed in the nucleus, and knockdown of FOXD2-AS1 weakened proliferative and migratory abilities in HepG2 cells. TWIST1 was upregulated in HCC tissues, which was positively correlated to FOXD2-AS1 level. The overexpression of TWIST1 could reverse the inhibited proliferative and migratory abilities in HepG2 cells with FOXD2-AS1 knockdown. CONCLUSIONS FOXD2-AS1 facilitates the progression of HCC by upregulating TWIST1.
Collapse
|