1
|
Internal Quality Control in Hemostasis Assays. Semin Thromb Hemost 2023. [PMID: 37748519 DOI: 10.1055/s-0043-1774381] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/27/2023]
Abstract
Internal quality control (IQC) for routine and specialist hemostasis testing represents a mandatory requirement for assays offered by clinical laboratories under International Organization for Standardization, Code of Federal Regulations, and Clinical and Laboratory Standards Institute standards. The underlying principle is that regular IQC audits the analytical performance of automated, semiautomated, and manual methods. This review investigates IQC practices, including benefits, limitations, frequency per time period or batch, sources of material used, primary supplier, third party or in-house, plus troubleshooting when IQC falls outside acceptance criteria. To assess IQC practice, the UK National External Quality Assessment Scheme (NEQAS) Blood Coagulation distributed a questionnaire to 1,200 participants enrolled in our scheme that collected details of the local practices for IQC testing. We received returns from 127 centers that described their local practices for the frequency of IQC, the type of IQC material employed, acceptance criteria for IQC data, and troubleshooting protocols for IQC failures. The data collected as part of an NEQAS BC questionnaire confirmed that all the participants returning answers to the questionnaire meet the standards for regular IQC testing for the hemostasis assays they perform.
Collapse
|
2
|
Anti-PF4 testing for vaccine-induced immune thrombocytopenia and thrombosis (VITT): Results from a NEQAS, ECAT and SSC collaborative exercise in 385 centers worldwide. J Thromb Haemost 2022; 20:1875-1879. [PMID: 35603519 DOI: 10.1111/jth.15766] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2022] [Revised: 03/10/2022] [Accepted: 03/11/2022] [Indexed: 10/18/2022]
Abstract
BACKGROUND Vaccine-induced immune thrombocytopenia and thrombosis (VITT) following the administration of the AstraZeneca (AZ) ChAdOx1 nCOV-19 vaccine is a well recognized clinical phenomenon. The associated clinical and laboratory features have included thrombosis at unusual sites, thrombocytopenia, raised D-dimer levels and positivity for immunoglobulin G (IgG) anti-platelet factor 4 (PF4) antibodies. OBJECTIVES A collaborative external quality assessment (EQA) exercise was carried out by distributing five lyophilized samples from subjects with VITT and one from a healthy subject to 500 centers performing heparin-induced thrombocytopenia (HIT) testing. METHODS Participating centers employed their locally validated testing methods for HIT assays, with some participants additionally reporting results for VITT modified assays. RESULTS A total of 385 centers returned results for anti-PF4 immunoassay and functional assays. The ELISA assays used in the detection of anti-PF4 antibodies for the samples distributed had superior sensitivities compared with both the functional assays and the non-ELISA methods. CONCLUSION ELISA-based methods to detect anti PF4 antibodies have a greater sensitivity in confirmation of VITT compared with functional assays regardless of whether such functional assays were modified to be specific for VITT. Rapid immunoassays should not be employed to detect VITT antibodies.
Collapse
|
3
|
External quality assessment for one-stage and chromogenic factor IX assays in samples containing Alprolix (rFIXFc) or Idelvion (rIX-FP) and evidence that UK National External Quality Assessment Scheme for blood coagulation samples are commutable with patient samples. Int J Lab Hematol 2022; 44:619-625. [PMID: 35040275 DOI: 10.1111/ijlh.13795] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2021] [Revised: 12/02/2021] [Accepted: 12/10/2021] [Indexed: 11/30/2022]
Abstract
INTRODUCTION There may be clinically relevant differences between results of different FIX assays in samples containing extended half life FIX concentrates requiring regular surveillance of assay results through proficiency testing exercises. Control materials used in proficiency testing must be commutable, that is have the same inter-assay properties as those demonstrated by authentic clinical samples when measured by different analytical methods. METHODS We assessed relationships between results with different FIX assays and commutability of UK National External Quality Assessment Scheme (NEQAS) materials containing rIX-FP (Idelvion) or rFIXFc (Alprolix) by comparing results obtained using widely used one-stage and chromogenic assays during a proficiency testing exercise with results obtained when analysing a series of individual patient samples using the same assay systems. NEQAS samples prepared by addition of either Idelvion or Alprolix to FIX deficient plasma were sent to 76 haemophilia centres in Europe. A total of 18 Idelvion and 22 Alprolix patient samples were assayed in a single centre. Two chromogenic and two one-stage assays were compared. RESULTS The pattern of results obtained for NEQAS samples and patient samples was similar. In all cases, the NEQAS sample data point was within the scatter of patient sample data in plots of patient sample results showing one-stage assay results using Synthasil or Actin FS plotted against chromogenic assay results with Biophen or Rox chromogenic FIX kits. CONCLUSION This indicates that the NEQAS samples containing Idelvion or Alprolix were commutable and therefore suitable for use in proficiency testing exercises.
Collapse
|
4
|
Anti-PF4 testing for vaccine-induced immune thrombocytopenia and thrombosis and heparin induced thrombocytopenia: Results from a UK National External Quality Assessment Scheme exercise April 2021. J Thromb Haemost 2021; 19:2263-2267. [PMID: 34227230 DOI: 10.1111/jth.15423] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2021] [Revised: 06/04/2021] [Indexed: 01/14/2023]
Abstract
BACKGROUND Vaccine-induced immune thrombocytopenia and thrombosis (VITT) following the administration of the AstraZeneca (AZ) ChAdOx1 nCOV-19 vaccine has recently been reported. The associated clinical and laboratory features have included thrombosis at unusual sites, thrombocytopenia, and raised D-dimers with positivity for IgG anti-platelet factor 4 (PF4) antibodies. OBJECTIVES A UK National External Quality Control Assessment Scheme external quality control exercise was carried out by distributing liquid and lyophilized samples from a subject with VITT, a pool of samples from subjects with classical heparin-induced thrombocytopenia (HIT), and a non-VITT/non-HIT case to 85 centers performing HIT testing. METHODS Participating centers employed their locally validated testing methods for HIT assays. RESULTS The lyophilized and liquid samples were found to be commutable for the ELISA assays used in the detection of anti-PF4 antibodies. The Aeskulisa, Stago, Hyphen, and LIFECODES anti-PF4 ELISA assays successfully detected the VITT antibody, whereas the Acustar HIT, Werfen LIA, and the Stago STIC assays did not. CONCLUSION It is important that clinical and laboratory teams are aware of the limitations of some anti-PF4 assays when using them to aid diagnosis of VITT syndrome.
Collapse
|
5
|
Pre-analytical variables in haemostasis: Findings from the United Kingdom National External Quality Assessment scheme for Blood Coagulation (UK NEQAS BC) haemolysis exercise. Int J Lab Hematol 2021; 43:1198-1206. [PMID: 33605545 DOI: 10.1111/ijlh.13468] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Revised: 12/15/2020] [Accepted: 12/27/2020] [Indexed: 11/30/2022]
Abstract
INTRODUCTION Haemolysis is considered one of the major contributors of nonconformities and sample rejection in coagulation testing. MATERIALS AND METHODS Two lyophilized plasmas were distributed to 800 centres registered for prothrombin time (PT), activated partial thromboplastin time (APTT) and either Clauss fibrinogen or thrombin time (TT) in the UK NEQAS BC programme. The same pool of normal plasma was used to prepare both samples, to one of which red blood cell haemolysate was added to mimic haemolysis at 3 g/L haemoglobin concentration. Participants were asked to complete a questionnaire about their laboratory approach to dealing with haemolysed samples, including strategies used to deal with different levels of haemolysis. RESULTS Results for tests performed did not show great differences between the two samples. It should be noted that artificially constructed haemolysed samples may not behave in the same way as patient samples (ie, may not be commutable). However, the possibility of carrying out a large multicentre study for detection of haemolysis was demonstrated. Inconsistency in practice was observed with 226/551 (41%) of centres indicated they reject haemolysed samples solely on visual checks, and 163 (30%) using initial visual checks with further sample rejection evaluation by analyser flags. Furthermore, 333 (72%) of centres indicated that the level of haemolysis affects sample rejection decisions, while 132 (28%) stated it did not. CONCLUSION Variability of responses for dealing with haemolysed samples reflects a lack of clear consistency in the pre-analytical area of sample processing.
Collapse
|
6
|
Effects of Emicizumab on APTT, FVIII assays and FVIII Inhibitor assays using different reagents: Results of a UK NEQAS proficiency testing exercise. Haemophilia 2020; 26:1087-1091. [DOI: 10.1111/hae.14177] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Revised: 09/15/2020] [Accepted: 09/22/2020] [Indexed: 11/26/2022]
|
7
|
Clotting and chromogenic factor VIII assay variability in post‐infusion and spiked samples containing full‐length recombinant FVIII or recombinant factor VIII Fc fusion protein (
rFVIIIF
c). Int J Lab Hematol 2018; 41:176-183. [DOI: 10.1111/ijlh.12940] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2018] [Revised: 10/01/2018] [Accepted: 10/05/2018] [Indexed: 12/30/2022]
|
8
|
Abstract
SummaryReported prevalence rates for protein C (PC) deficiency in the population at large have varied widely. The differences presumably reflect the existence of an apparently high number of clinically recessive forms of the deficiency. In an attempt to document more precisely the prevalence of PC deficiency in the healthy population we have measured PC activity in just under 10,000 blood donors in the West of Scotland. After repeat testing of donors with low results and then further observation and selection, 32 donors were identified who had individual mean PC activities below the age- and gender-specific study reference range. Assessment of available first degree relatives, and also PC gene analysis in 23 of these donors, allowed identification of at least 14 with an inheritable deficiency (8 by both family study and gene analysis, 3 by family study alone and 3 by gene analysis alone). Two recurring and seven unique point mutations, only one of which has been previously described, were identified. The observed prevalence of inherited PC deficiency was 1.45 per 1000 (95% Cl, 0.79/1000 to 2.43/1000). However after correcting for the possibility of missing some genuine inherited deficiencies we estimated the prevalence to be as high as 1 in 500. All cases of hereditary deficiency were asymptomatic with regard to thrombosis and none had a strong family history of thrombosis. These findings confirm the rather frequent occurrence of asymptomatic individuals with PC deficiency and support the hypothesis that additional defects in the anticoagulant pathways may be required to confer a high-thrombotic-risk phenotype.
Collapse
|
9
|
Thromboplastin Related Differences in the Determination of International Normalised Ratio: A Cause for Concern? Thromb Haemost 2018. [DOI: 10.1055/s-0038-1648883] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
SummaryWhen the International Normalised Ratio (INR) is used for control of oral anticoagulant therapy the same result should be obtained irrespective of the laboratory reagent used. However, in the UK National External Quality Assessment Scheme (NEQAS) for Blood Coagulation INRs determined using different reagents have been significantly different.For 18 NEQAS samples Manchester Reagent (MR) was associated with significantly lower INRs than those obtained using Diagen Activated (DA, p = 0.0004) or Instrumentation Laboratory PT-Fib HS (IL, p = 0.0001). Mean INRs for this group were 3.15, 3.61, and 3.65 for MR, DA, and IL respectively. For 61 fresh samples from warfarin-ised patients with INRs of greater than 3.0 the relationship between thromboplastins in respect of INR was similar to that observed for NEQAS data. Thus INRs obtained with MR were significantly lower than with DA or IL (p <0.0001). Mean INRs for this group were 4.01, 4.40, and 4.59 for MR, DA, and IL respectively.We conclude that the differences between INRs measured with the thromboplastins studied here are sufficiently great to influence patient management through warfarin dosage schedules, particularly in the upper therapeutic range of INR. There is clearly a need to address the issues responsible for the observed discrepancies.
Collapse
|
10
|
Abstract
SummaryBRL 26921 is the p-anisoyl derivative of the primary streptokinase-human plasminogen complex in which the acyl group is specifically located at the catalytic centre of the enzyme. Doses of BRL 26921 ranging from 5 mg to 25 mg were given intravenously or into a coronary artery to 12 patients with acute myocardial infarction. The complex was well tolerated and produced no serious bleeding. Coronary artery reperfusion was demonstrated angiographically in three patients.In most patients, fibrinogen, plasminogen, α2 antiplasmin and a2 macroglobulin levels fell and the level of fibrinogen degradation products increased acutely post treatment indicating systemic fibrinolytic activation. The degree of this activation was variable but was profound in some. It appeared to be dose related and modified by the presence of streptokinase antibodies. BRL 26921 appears less “selectively” thrombolytic in patients than had been expected from animal models.
Collapse
|
11
|
Triton X-114 Phase Separation of Platelet Membrane Glycoproteins from Normal Subjects and a Patient with Type I Thrombasthenia. Thromb Haemost 2018. [DOI: 10.1055/s-0038-1661456] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
SummarySurface-labelled normal and thrombasthenic platelets have been subjected to phase separation in Triton X-114. Triton-rich and Triton-poor fractions have been analysed by SDS-PAGE and IEF-SDS-PAGE. Partitioning characteristics of the major glycoproteins have been defined. The Triton-rich fraction contained GPIIb, III, IV, VI, VII, VIII, GP38 and the IIb β subunit. In contrast, the Triton-poor fraction contained the HMWGP, GPIa, Ib, IIb, III, V and GPIX.Analysis of the platelet membrane glycoproteins of a patient with Type 1 thrombasthenia has been carried out using Triton X-114. The value of the method in diagnosis of this condition and differences between our findings and those published previously are discussed.
Collapse
|
12
|
The Effect of the Synthetic Steroid ORG OD14 on Fibrinolysis and Blood Lipids in Postmenopausal Women. Thromb Haemost 2018. [DOI: 10.1055/s-0038-1661302] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
SummaryTwo groups of postmenopausal women were compared. One group of 13 was given the synthetic steroid Org OD14 to suppress climacteric symptoms and one group of 14 was given placebo. After a 2 week baseline period the subjects received daily for 12 weeks, either 2.5 mg Org OD14 or placebo. There were no significant differences between the groups pre-treatment. Compared with the placebo group, during treatment, the Org OD14 group showed the following significant differences: higher haemoglobin, haematocrit, platelet count, plasminogen, fibrinolytic activity on fibrin plates and antithrombin III and lower fibrinogen. No significant differences between the groups were found in α2 antiplasmin levels, total cholesterol, total triglycerides, bilirubin or transaminase levels but the Org OD14 group had significantly lower levels of HDL cholesterol. With the exception of the haemoglobin and haematocrit levels all of the differences had disappeared by 2 weeks post treatment.
Collapse
|
13
|
Effect of Ciprofibrate on Platelet Aggregation and Fibrinolysis in Patients with Hypercholesterolaemia. Thromb Haemost 2018. [DOI: 10.1055/s-0038-1657868] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
SummaryThe fibrinolytic and platelet effects of Ciprofibrate, a new lipid lowering drug, were studied in 7 patients with hypercholesterolaemia over a 12 week period. A significant reduction in plasma fibrinogen was noted and a lesser increase in fibrinolytic activity. However, no change in platelet aggregation was noted. As expected Ciprofibrate produced a significant hypolipidaemic effect in these patients.We have described effects of Ciprofibrate which may have potential benefits in this high risk patient group.
Collapse
|
14
|
Abstract
SummaryIn an attempt to reduce the incidence of pregnancy associated venous thromboembolism (PA-VTE), some researchers have advocated screening of all women for the factor VLeiden mutation during early pregnancy. We have conducted a large retrospective study (over 72,000 deliveries) to determine if this would be useful. Sixty-two objectively confirmed venous thrombotic events (51 DVT, 11 PE) were recorded at two maternity units in the UK. The incidence of DVT was 0.71 per 1000 deliveries (95% CI 0.5-0.9) with 0.50 occurring in the antenatal period (95% CI 0.34-0.66) and 0.21 in the puerperium (95% CI 0.11-0.31). The incidence of PE was 0.15 per 1000 deliveries (95% CI 0.06-0.24), 0.07 antenatal (95% CI 0.01-0.13) and 0.08 in the puerperium (95% CI 0.02-0.14). Of these 62,50 attended for follow-up and thrombophilia screening. 28% of all episodes of PA-VTE had no CIinical risk factor for thrombosis or an identifiable thrombophilic abnormality. Deficiency of antithrombin was identified in 12% of individuals (95% CI 3-21) and the factor VLeiden mutation in 8% (95% CI 0.5-15.5). Based on estimates of the prevalence of the factor VLeiden mutation in the population, we estimate that the thrombotic risk for a woman during pregnancy or the puerperium with the defect is approximately 1 in 400-500. This figure would not lend support to the idea of random screening for the mutation in early pregnancy.
Collapse
|
15
|
Abstract
SummaryDespite many reports of individuals with congenital plasminogen deficiency and thrombosis, there is still uncertainty whether heterozygous deficiency represents a real thrombophilic risk factor or simply a coincidental finding. We have addressed this issue by testing for plasminogen deficiency in a cohort of 9611 blood donors. Out of 66 donors with reduced plasminogen activity on two occasions 28 were shown to have a familial deficiency state (including 3 with dysplasminogen-aemia). Our observed prevalence rate for familial plasminogen deficiency, calculated at 2.9/1000 (95% Cl = 1.9-4.2 per 1000), was not significantly different from that calculated from published reports of congenital plasminogen deficiency in thrombotic cohorts (5.4/1000). Furthermore, with only two exceptions, all 80 donors and relatives with familial deficiency were asymptomatic with regard to thrombosis -including a 29 year old donor with suspected compound heterozygous hypoplasminogenaemia. These findings add further weight to the argument that familial heterozygous plasminogen deficiency, at least in isolation, does not constitute a significant thrombotic risk factor. However, it remains uncertain whether plasminogen deficiency, when combined with other thrombophilic conditions, may become more clinically important.
Collapse
|
16
|
Two Recombinant Tissue Factor Reagents Compared to Conventional Thromboplastins for Determination of International Normalised Ratio: A Thirty-three-laboratory Collaborative Study. Thromb Haemost 2018. [DOI: 10.1055/s-0038-1650586] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
SummaryRecent advances in recombinant technology have led to the development of prothrombin time (PT) reagents containing recombinant tissue factor which has been lipidated to allow expression of procoagulant activity. In this study we have compared International Normalised Ratios (INRs) determined using two such reagents and conventional thromboplastins in widespread use in the UK.Lyophilised plasma samples from eight different warfarinised patients were distributed to 33 laboratories in the UK. Each participant determined prothrombin times on 20 local fresh normal plasmas (used to derive mean normal PT and calculate INR) and the eight lyophilised samples, using manual technique and the following thromboplastins; Recombiplastin (Ortho Diagnostics Ltd); Innovin (Baxter Diagnostics Ltd); the conventional thromboplastin in local use.For eight plasmas the mean INRs determined with different reagents were as follows: Innovin (33 laboratories) - 3.4; Manchester Reagent (MR = 8 laboratories) - 3.4; Recombiplastin (33 laboratories) - 3.7; Instrumentation Laboratory (IL = 13 laboratories) - 4.4.Mean INR results with Recombiplastin were on average 7% greater than those obtained with Innovin, 8% greater than results with MR and 18% less than INRs with IL thromboplastin. There was no significant difference between results obtained with Innovin and MR. In contrast INRs obtained with IL were markedly (mean 28%) greater than results obtained with Innovin.This study employed lyophilised plasma and it is possible that some of the relationships described are influenced by this. However, the lyo-philisation process employed did not influence the relationship between INRs of warfarinised plasmas obtained by the four main reagents described, indicating that the results are relevant to routine clinical practice.In conclusion, our data show some important differences are present between INRs determined using Recombiplastin, Innovin and two conventional thromboplastins.
Collapse
|
17
|
Plasminogen Levels in Healthy Volunteers -Influence of Age, Sex, Smoking and Oral Contraceptives. Thromb Haemost 2018. [DOI: 10.1055/s-0038-1646308] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
SummaryThere is considerable doubt as to the importance of reduced plasminogen (PLG) activity as a risk factor for venous thrombosis. In the present study we have identified a wide range of PLG activities (25–200%) in a cohort of 9,611 blood donors. Males and females not taking hormonal contraceptives show a similar distribution of PLG, however, variation related to age appears to follow a different pattern in males and females. These differences are of doubtful clinical importance as are differences related to smoking. In contrast, females taking hormonal contraceptives or hormone replacement therapy (HRT) have up to 25% higher mean PLG levels in younger females but a less marked elevation (10%) is seen in 40–50 year olds. A PLG activity <65% was recorded in 61 donors, none of whom appeared to have a history of thrombosis. These findings do not support the notion that reduced PLG is an important thrombophilic risk factor, however, further investigation of the donors with low PLG is required.
Collapse
|
18
|
Protein C Activity in Healthy Volunteers - Influence of Age, Sex, Smoking and Oral Contraceptives. Thromb Haemost 2018. [DOI: 10.1055/s-0038-1649566] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
SummaryInterpretation of protein C (PC) levels in a given individual has several limitations. A normal PC activity does not necessarily exclude a genetic deficiency nor can a reduced level confirm it. Measuring PC amidolytic activity in 9,648 healthy blood donors has allowed identification of demographic factors which cause variation in PC activity and further hinder interpretation. PC activity displays a log normal distribution and significant variation with age. This is most marked in young adult males when mean PC activity rises from 0.86 iu/ml (15–19 years) to 1.04 iu/ml (45–49 years; P <0.0001). Pre-menopausal females, who for most age ranges, have mean PC activity below their male contemporaries, show a less marked rise with age until the menopause when PC activity rises further. The use of hormonal contraceptive preparations is associated with an increase in mean PC activity of 0.05–0.08 iu/ml while smoking habit has no influence on PC activity.In view of these findings we strongly recommend the use of age and sex restricted reference ranges when interpreting PC activity.
Collapse
|
19
|
|
20
|
Abstract
Anabolic steroid therapy enhances fibrinolytic activity and it has been suggested that, since degenerative and thrombotic arterial diseases may be associated with impaired plasma fibrinolysis, anabolic steroids may be of potential therapeutic value in these disorders. The evidence for the use of anabolic steroids in peripheral and in coronary arterial disorders is reviewed.
Collapse
|
21
|
Factor VIII assay variability in postinfusion samples containing full length and B-domain deleted FVIII. Haemophilia 2016; 22:806-12. [PMID: 27217329 DOI: 10.1111/hae.12962] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/14/2016] [Indexed: 11/29/2022]
Abstract
INTRODUCTION Although the variability in factor VIII (FVIII):C measurement is well recognized, this has not been widely reported for post-FVIII infusion samples. AIM/METHODS Three samples from haemophilia A patients were distributed in a UK National External Quality Assessment Scheme survey, each after treatment with either ReFacto AF, Kogenate FS or Advate. Fifty-two UK haemophilia centres performed FVIII assays using one-stage (n = 46) and chromogenic (n = 10) assays. Centres calibrated assays with the local plasma standard and with ReFacto AF laboratory standard for the ReFacto AF sample. RESULTS/CONCLUSIONS Chromogenic assays gave significantly higher results than one-stage assays (P < 0.0001, 32% difference) in the post-Kogenate sample but not in the post-ReFacto AF (11% higher by chromogenic assay, ns) or post-Advate samples (3% lower by chromogenic, ns) when assays were calibrated with plasma standards. Twenty centres used all Instrumentation Laboratory (IL)-activated partial thromboplastin time reagents (Synthasil)/IL deficient plasma/reference plasma) in the one-stage assay and 15 used all Siemens reagents (Actin FS/Siemens deficient plasma/reference plasma); this made a significant difference to results post-ReFacto AF (41% higher by IL reagents, P < 0.0001) and Advate (39% higher by IL reagents, P < 0.0001), but not Kogenate (7% higher by IL, ns) when calibrated with plasma standards. Differences between results obtained with different one-stage assay reagents for monitoring Advate have implications for dosing patients. Furthermore, there was considerable inter-laboratory variation as indicated by CVs in the range 15-26% for chromogenic assay and 12-19% for one-stage assay results. This study suggests that external quality assessment schemes should offer participation in post-FVIII infusion schemes where haemophilic patients are monitored.
Collapse
|
22
|
|
23
|
Confirmation of genetic testing results in haemostasis and thrombosis - survey of current practice in the field. Haemophilia 2016; 22:e239-41. [PMID: 27037964 DOI: 10.1111/hae.12934] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/26/2016] [Indexed: 11/30/2022]
|
24
|
Point of Care INR testing devices: performance of the Roche CoaguChek XS and XS Plus in the UK NEQAS BC external quality assessment programme for healthcare professionals: four years' experience. J Clin Pathol 2012; 65:1119-23. [PMID: 23038688 DOI: 10.1136/jclinpath-2012-201049] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
BACKGROUND Vitamin K antagonists have been used for many decades and have been traditionally monitored by the measurement of the International Normalised Ratio (INR) in the laboratory. Introduction of Point of Care (POC) testing devices to measure INR has resulted in many tests being undertaken in primary care. External Quality Assessment (EQA) of these POC devices is recommended to ensure accuracy and reliability of INR results outside a laboratory setting. AIM To assess the quality of INR results for users of two POC devices (CoaguChek XS and CoaguChek XS Plus) over a four-year period. METHODS Four surveys (two samples) were sent in each 12-month period. The median INR value of each sample was calculated and the percentage deviation from this median determined. Any results greater than 15% from the median were considered to be outside consensus which indicated a possible problem within the testing system. RESULTS Variability of INR results in this UK National External Quality Assessment Scheme (NEQAS) programme was comparable to that in the UK NEQAS EQA programme for laboratory INR testing. Occurrence of persistent problems was lower in the POC programme than the laboratory programme. CONCLUSIONS Utilisation of an EQA programme for POC devices in primary care is feasible and necessary. Our data suggest for those health professionals using EQA, the reliability and accuracy of INR testing matches the quality of laboratory testing.
Collapse
|
25
|
Novel analysis of clinically relevant diagnostic errors in point-of-care devices: a rebuttal. J Thromb Haemost 2012; 10:1191-2; author reply 1192-4. [PMID: 22646833 DOI: 10.1111/j.1538-7836.2012.04722.x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
26
|
ISTH/SSC lupus anticoagulant testing guidelines: how far have these been adopted by laboratories? J Thromb Haemost 2011; 9:2117-9. [PMID: 21794074 DOI: 10.1111/j.1538-7836.2011.04448.x] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
27
|
Cerebral venous thrombosis and pulmonary thromboembolism with thyrotoxicosis. Scott Med J 2009. [DOI: 10.1258/rsmsmj.54.2.58f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
An elevated level of factor VIII is a recognised risk factor for thromboembolism. This case report describes a patient with elevated factor VIII levels secondary to hyperthyroidism. She presented with a triad of clinical hyperthyroidism, pulmonary emboli and cerebral venous thrombosis. This case highlights the importance of considering thromboprophylaxis in patients with clinical hyperthyroidism.
Collapse
|
28
|
Platelet function testing: practice among UK National External Quality Assessment Scheme for Blood Coagulation participants, 2006. J Clin Pathol 2008; 61:950-4. [DOI: 10.1136/jcp.2008.057174] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
|
29
|
Factor VIII inhibitor associated with hepatocellular carcinoma. CLINICAL AND LABORATORY HAEMATOLOGY 2008; 15:145-8. [PMID: 8394235 DOI: 10.1111/j.1365-2257.1993.tb00139.x] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
|
30
|
Laboratory D-dimer measurement: improved agreement between methods through calibration. Thromb Haemost 2008; 98:1127-35. [PMID: 18000620 DOI: 10.1160/th07-05-0377] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Accurate and precise measurement of plasma D-dimer levels is important in the diagnosis and management of venous thromboembolism. Considerable variability in D-dimer results obtained using different methods has, however, been reported in multicentre studies. This study explored in two separate multicentre exercises the degree of precision amongst laboratory D-dimer measurements, and the degree by which inter-method agreement could be improved using a calibration curve model. The first exercise demonstrated generally good within-centre precision, with 82% of the centres reporting results for two identical but differently coded samples within 10% of each other. However, six centres reported results which would have excluded deep vein thrombosis (DVT) for one sample but failed to exclude DVT for the other, identical sample. In the second exercise, overall between-method precision of D-dimer results for two samples was shown to improve markedly when a calibration model was applied, using the consensus median values obtained by all participants for three "calibration plasmas" to recalculate D-dimer values. For centres reporting results in fibrinogen equivalent units (FEUs), between-centre coefficients of variation (CVs) fell from 25.9% to 11.6% and 22.4% to 7.7%, respectively, for the two samples. For centres reporting in ng/ml, CVs fell from 45.3-21.6% and 40.8-11.6%, respectively. In conclusion, improved harmonisation of D-dimer results by different methods may be achieved by a calibration model and common calibrant plasmas.
Collapse
|
31
|
The GOAL study: a prospective examination of the impact of factor V Leiden and ABO(H) blood groups on haemorrhagic and thrombotic pregnancy outcomes. Br J Haematol 2007; 140:236-40. [PMID: 18028481 DOI: 10.1111/j.1365-2141.2007.06902.x] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
Factor V Leiden (FVL) and ABO(H) blood groups are the common influences on haemostasis and retrospective studies have linked FVL with pregnancy complications. However, only one sizeable prospective examination has taken place. As a result, neither the impact of FVL in unselected subjects, any interaction with ABO(H) in pregnancy, nor the utility of screening for FVL is defined. A prospective study of 4250 unselected pregnancies was carried out. A venous thromboembolism (VTE) rate of 1.23/1000 was observed, but no significant association between FVL and pre-eclampsia, intra-uterine growth restriction or pregnancy loss was seen. No influence of FVL and/or ABO(H) on ante-natal bleeding or intra-partum or postpartum haemorrhage was observed. However, FVL was associated with birth-weights >90th centile [odds ratio (OR) 1.81; 95% confidence interval (CI(95)) 1.04-3.31] and neonatal death (OR 14.79; CI(95) 2.71-80.74). No association with ABO(H) alone, or any interaction between ABO(H) and FVL was observed. We neither confirmed the protective effect of FVL on pregnancy-related blood loss reported in previous smaller studies, nor did we find the increased risk of some vascular complications reported in retrospective studies.
Collapse
|
32
|
Emerging Technologies and Quality Assurance: The United Kingdom National External Quality Assessment Scheme Perspective. Semin Thromb Hemost 2007; 33:243-9. [PMID: 17427058 DOI: 10.1055/s-2007-971810] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
The pattern of tests employed and technologies developed within hemostasis laboratories has changed considerably within the last 10 years. These changes have presented challenges to external quality assessment (EQA) providers, including the United Kingdom National External Quality Assessment Scheme (NEQAS). EQA for point-of-care devices used for monitoring oral anticoagulant therapy has focused on provision of suitable material to assess performance of devices designed for capillary blood testing, and on education of a user group not usually trained in laboratory quality control procedures. Development of novel therapeutic agents for hemophilia has presented challenges regarding standardization of assays for monitoring treatment, whereas advances related to laboratory testing and automation have not always been accompanied by improved accuracy and precision. EQA provision has also been shown to be of value in molecular genetic screening tests for thrombophilia, and in highlighting standardization issues related to D-dimer measurement in the exclusion of deep vein thrombosis. The increasing prevalence of screening tests of global hemostasis, such as thrombin generation tests and thromboelastography, presents additional challenges to EQA providers in the attempt to standardize these new and potentially beneficial technologies.
Collapse
|
33
|
Point-of-care International Normalised Ratios: UK NEQAS experience demonstrates necessity for proficiency testing of three different monitors. Thromb Haemost 2006; 96:590-6. [PMID: 17080215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
External quality assessment (EQA) or proficiency testing is widely considered to be necessary for International Normalised Ratio (INR) determinations performed in conventional laboratory settings. There is increasing use of near-patient-test (NPT) or point-of-care (POC) INR devices and it is not known whether EQA is also necessary for these monitors. We report here on six years experience of proficiency testing for POC monitors used by health care professionals. Three devices were used by >10 centres who participated in the programme, the CoaguChek (CUC), the CUC-S and the TAS or Rapidpoint Coag. Not all users of the same type of monitor obtained the same INR result when analysing the same plasma sample. For the three monitors the CV of results in different centres was 11-14%. The variation between results in different centres could relate to inappropriately handled proficiency testing material, inaccuracies in the calibration of the system by the manufacturer or deterioration during transport/storage of the test strips. In each survey 10-11% of centres using POC monitors obtained INR results which were >15% different from those in other centres using the same monitors. For hospital laboratories using conventional INR techniques this figure was 12%. The relationship between INR results obtained by users of the Rapidpoint Coag or TAS monitor and results obtained by conventional techniques was not constant over the period of study. During one period INRs with TAS were 13.7% greater than with conventional methods. For the remaining three time periods results were similar. Our data suggest that the variation between INR results determined with three POC monitors show similar variation to that observed in hospital laboratories using conventional methods. Based on our data we recommend that users of these POC monitors participate regularly in an independent external proficiency testing programme.
Collapse
|
34
|
Abstract
Worldwide, hundreds of millions of women use exogenous estrogens in contraceptives or for postmenopausal hormone replacement. Exogenous estrogens increase the risk for venous and arterial thrombosis. This article reviews the use of exogenous sex hormones in women with thrombophilia.
Collapse
|
35
|
Screening for thrombophilia in high-risk situations: systematic review and cost-effectiveness analysis. The Thrombosis: Risk and Economic Assessment of Thrombophilia Screening (TREATS) study. Health Technol Assess 2006; 10:1-110. [PMID: 16595080 DOI: 10.3310/hta10110] [Citation(s) in RCA: 190] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
OBJECTIVES To assess the risk of clinical complications associated with thrombophilia in three high-risk patient groups: women using oral oestrogen preparations, women during pregnancy and patients undergoing major orthopaedic surgery. To assess the effectiveness of prophylactic treatments in preventing venous thromboembolism (VTE) and adverse pregnancy outcomes in women with thrombophilia during pregnancy and VTE in patients with thrombophilia, undergoing major orthopaedic surgery. To evaluate the relative cost-effectiveness of universal and selective VTE history-based screening for thrombophilia compared with no screening in the three high-risk patient groups. DATA SOURCES Electronic databases including MEDLINE, EMBASE, and four other major databases were searched up to June 2003. REVIEW METHODS In order to assess the risk of clinical complications associated with thrombophilia, a systematic review of the literature on VTE and thrombophilia in women using oral oestrogen preparations and patients undergoing major orthopaedic surgery; and studies of VTE and adverse obstetric complications in women with thrombophilia during pregnancy was carried out. Meta-analysis was used to calculate pooled odds ratios (ORs) associated with individual clinical outcomes, stratified by thrombophilia type and were calculated for each patient group. To assess the effectiveness of prophylaxis, a systematic review was carried out on the use of prophylaxis in the prevention of VTE and pregnancy loss in pregnant women with thrombophilic defects and the use of thromboprophylaxis in the prevention of VTE in patients with thrombophilia undergoing major elective orthopaedic surgery. Relevant data were summarised according to the patient groups and stratified according to the types of prophylaxis. A narrative summary was provided; where appropriate, meta-analysis was conducted. An incremental cost-effectiveness analysis was then carried out, from the perspective of the NHS in the UK. A decision analytical model was developed to simulate the clinical consequences of four thrombophilia screening scenarios. Results from the meta-analyses, information from the literature and results of two Delphi studies of clinical management of VTE and adverse pregnancy complications were incorporated into the model. Only direct health service costs were measured and unit costs for all healthcare resources used were obtained from routinely collected data and the literature. Cost-effectiveness was expressed as incremental cost-effectiveness ratios (ICERs); an estimate of the cost per adverse clinical complication prevented, comparing screening with no screening, were calculated for each patient group. RESULTS In the review of risk of clinical complications, 81 studies were included, nine for oral oestrogen preparations, 72 for pregnancy and eight for orthopaedic surgery. For oral contraceptive use, significant associations of the risk of VTE were found in women with factor V Leiden (FVL); deficiencies of antithrombin, protein C, or protein S, elevated levels of factor VIIIc; and FVL and prothrombin G20210A. For hormone replacement therapy (HRT), a significant association was found in women with FVL. The highest risk in pregnancy was found for FVL and VTE, in particular, homozygous carriers of this mutation are 34 times more likely to develop VTE in pregnancy than non-carriers. Significant risks for individual thrombophilic defects were also established for early, recurrent and late pregnancy loss; preeclampsia; placental abruption; and intrauterine growth restriction. Significant associations were found between FVL and high factor VIIIc and postoperative VTE following elective hip or knee replacement surgery. Prothrombin G20210A was significantly associated with postoperative pulmonary embolism. However, antithrombin deficiency, MTHFR and hyperhomocysteinaemia were not associated with increased risk of postoperative VTE. In the review of the effectiveness of prophylaxis, based on available data from eight studies, low-dose aspirin and heparin was found to be the most effective in preventing pregnancy loss in thrombophilic women during pregnancy, while aspirin alone was the most effective in preventing minor bleeding. All the studies on thrombophilia and major elective orthopaedic surgery included in the review of risk complications were also used in the review of the effectiveness of thromboprophylaxis. However, there were insufficient data to determine the relative effectiveness of different thromboprophylaxis in preventing VTE in this patient group. For the cost-effectiveness analysis, of all the patient groups evaluated, universal screening of women prior to prescribing HRT was the most cost-effective (ICER pound6824). In contrast, universal screening of women prior to prescribing combined oral contraceptives was the least cost-effective strategy (ICER pound202,402). Selective thrombophilia screening based on previous personal and/or family history of VTE was more cost-effective than universal screening in all the patient groups evaluated. CONCLUSIONS Thrombophilia is associated with increased risks of VTE in women taking oral oestrogen preparations and patients undergoing major elective orthopaedic surgery, and of VTE and adverse pregnancy outcomes in women with thrombophilia during pregnancy. There is considerable difference in the magnitude of the risks among different patient groups with different thrombophilic defects. In women who are on combined oral contraceptives, the OR of VTE among those who are carriers of the FVL mutation was 15.62 (95% confidence interval 8.66 to 28.15). However, in view of the prevalence of thrombophilia and the low prevalence of VTE in non-users of combined oral contraceptives, the absolute risk remains low. Significant risks for VTE and adverse pregnancy outcomes have been established with individual thrombophilic defects. Thrombophilic defects including FVL, high plasma factor VIIIc levels and prothrombin G20210A are associated with the occurrence of postoperative VTE in elective hip or knee replacement therapy. These associations are observed in patients who were given preoperative thromboprophylaxis and are, therefore, of clinical significance. Universal thrombophilia screening in women prior to prescribing oral oestrogen preparations, in women during pregnancy and in patients undergoing major orthopaedic surgery is not supported by current evidence. The findings from this study show that selective screening based on prior VTE history is more cost-effective than universal screening. Large prospective studies should be undertaken to refine the risks and establish the associations of thrombophilias with VTE among hormone users and in patients undergoing orthopaedic surgery. The relative value of a thrombophilia screening programme to other healthcare programmes needs to be established.
Collapse
|
36
|
Laboratory Tests for Measurement of von Willebrand Factor Show Poor Agreement among Different Centers: Results from the United Kingdom National External Quality Assessment Scheme for Blood Coagulation. Semin Thromb Hemost 2006; 32:492-8. [PMID: 16862522 DOI: 10.1055/s-2006-947863] [Citation(s) in RCA: 68] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
In recognition of the importance of von Willebrand factor (vWF) testing in the diagnosis of von Willebrand disease (vWD), the United Kingdom National External Quality Assessment Scheme for Blood Coagulation regularly distributes samples for determination of vWF:antigen (vWF:Ag). Data from 10 separate surveys performed between 2001 and 2005 are reviewed. These include results from ~200 different centers, of which 55% are within the United Kingdom and the remainder are from other countries. During the period of the surveys, the use of immunoelectrophoresis for determination of vWF:Ag practically disappeared and was largely replaced by latex agglutination assays. The coefficient of variation (CV) of results in different centers was approximately 15 to 20% for most vWF:Ag techniques, with CVs of approximately 7% for a fluorescence-based assay. Several different techniques were used for determination of vWF ristocetin cofactor activity (vWF:RCo), all of which were associated with poor agreement among centers as indicated by CVs of 40 to 50%. Several centers calculated the ratio of vWF:Ag/vWF:RCo but with variable success. Ratios compatible with either type 1 or type 2 vWD were obtained on samples from subjects with type 1 vWD, as well as on samples from subjects with genetically confirmed type 2 vWD. Overall, our data show that laboratory testing for vWD remains problematic. It remains to be seen whether newer techniques will offer consistently improved precision.
Collapse
|
37
|
Abstract
Growing evidence suggests that thrombophilia is associated with venous thromboembolism (VTE) and adverse pregnancy outcomes. However, methodological limitations have made it difficult to obtain a clear overview of the overall risks. We conducted a systematic review to determine the risk of VTE and adverse pregnancy outcomes associated with thrombophilia in pregnancy. The effectiveness of prophylactic interventions during pregnancy was also evaluated. Major electronic databases were searched, relevant data abstracted and study quality assessed by two independent reviewers. Odds ratios (ORs) stratified by thrombophilia type were calculated for each outcome. A total of 79 studies were included in our review. The risks for individual thrombophilic defects were determined for VTE (ORs, 0.74-34.40); early pregnancy loss (ORs, 1.40-6.25); late pregnancy loss (ORs, 1.31-20.09); pre-eclampsia (ORs, 1.37-3.49); placental abruption (ORs, 1.42-7.71) and intrauterine growth restriction (ORs, 1.24-2.92). Low-dose aspirin plus heparin was the most effective in preventing pregnancy loss in thrombophilic women (OR, 1.62). Our findings confirm that women with thrombophilia are at risk of developing VTE and complications in pregnancy. However, despite the increase in relative risk, the absolute risk of VTE and adverse outcomes remains low. There is also a lack of controlled trials of antithrombotic intervention to prevent pregnancy complications. Thus, at present, universal screening for thrombophilia in pregnancy cannot be justified clinically.
Collapse
|
38
|
|
39
|
Oral contraceptives, hormone replacement therapy, thrombophilias and risk of venous thromboembolism: a systematic review. The Thrombosis: Risk and Economic Assessment of Thrombophilia Screening (TREATS) Study. Thromb Haemost 2005; 94:17-25. [PMID: 16113779 DOI: 10.1160/th04-11-0759] [Citation(s) in RCA: 99] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Combined oral contraceptives, oral hormone replacement therapy and thrombophilias are recognised risk factors for venous thromboembolism in women. The objective of this study was to assess the risk of thromboembolism among women with thrombophilia who are taking oral contraceptives or hormone replacement therapy, conducting a systematic review and metaanalysis. Of 201 studies identified, only nine met the inclusion criteria. Seven studies included pre-menopausal women on oral contraceptives and two studies included peri-menopausal women on hormone replacement therapy. For oral contraceptive use, significant associations of the risk of venous thromboembolism were found in women with factor V Leiden (OR 15.62; 95%CI 8.66 to 28.15); deficiencies of antithrombin (OR 12.60; 95%CI 1.37 to 115.79), protein C (OR 6.33; 95%CI 1.68 to 23.87), or protein S (OR 4.88; 95%CI 1.39 to 17.10), elevated levels of factor VIIIc (OR 8.80; 95%CI 4.13 to 18.75); and factor V Leiden and prothrombin G20210A (OR 7.85; 95%CI 1.65 to 37.41). For hormone replacement therapy, a significant association was found in women with factor V Leiden (OR 13.16; 95%CI 4.28 to 40.47). Although limited by the small number of studies, the findings of this study support the presence of interaction between thrombophilia and venous thromboembolism among women taking oral contraceptives. However, further studies are required to establish with greater confidence the associations of these, and other, thrombophilias with venous thromboembolism among hormone users.
Collapse
|
40
|
Point of care testing by health care professionals: current practice amongst the UK National External Quality Assessment Scheme Participants. Br J Haematol 2005; 130:320-1. [PMID: 16029464 DOI: 10.1111/j.1365-2141.2005.05610.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
41
|
Abstract
OBJECTIVE Few comprehensive data are available on the recurrence rate of venous thrombosis in carriers of thrombophilic defects from thrombophilic families. We prospectively determined the recurrence rate after a first venous thrombotic event in patients with familial thrombophilia attributable to factor V Leiden or deficiencies of protein C, S, or antithrombin. METHODS AND RESULTS Data were gathered during follow-up on the occurrence of risk situations, anticoagulation treatment, and events (eg, venous thrombosis, hemorrhage). Over a mean follow-up period of 5.6 years, 44 of the 180 patients with familial thrombophilia who did not use long-term anticoagulation experienced a recurrent venous thromboembolic event (5.0%/year; 95% CI 3.6 to 6.7) compared with 7 of the 124 patients on long-term anticoagulation (1.1%/year; 95% CI 0.4 to 2.2). Spontaneous events occurred less often in patients on long-term anticoagulation (57%) than in patients without long-term anticoagulation (75%). The highest recurrence rate was found among men with a deficiency in natural anticoagulants or multiple defects and women with antithrombin deficiency. Although long-term anticoagulation treatment decreased the incidence of recurrent events by 80%, it also resulted in a risk of major hemorrhage of 0.8% per year. CONCLUSIONS Extra care after a first event is required for men with a deficiency in natural anticoagulants or multiple defects and women with antithrombin deficiency.
Collapse
|
42
|
|
43
|
Thrombophilia and venous thromboembolism after total hip or knee replacement surgery: a systematic review. J Thromb Haemost 2005; 3:811-3. [PMID: 15842382 DOI: 10.1111/j.1538-7836.2005.01264.x] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
44
|
Risk of a first venous thrombotic event in carriers of a familial thrombophilic defect. The European Prospective Cohort on Thrombophilia (EPCOT). J Thromb Haemost 2005; 3:459-64. [PMID: 15748234 DOI: 10.1111/j.1538-7836.2005.01197.x] [Citation(s) in RCA: 131] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
BACKGROUND Reliable risk estimates for venous thrombosis in families with inherited thrombophilia are scarce but necessary for determining optimal screening and treatment policies. OBJECTIVES In the present analysis, we determined the risk of a first venous thrombotic event in carriers of a thrombophilic defect (i.e. antithrombin-, protein C- or protein S deficiency, or factor V Leiden). PATIENTS AND METHODS The asymptomatic carriers had been tested prior to this study in nine European thrombosis centers because of a symptomatic carrier in the family, and were followed prospectively for 5.7 years on average between March 1994 and January 2001. Annually, data were recorded on the occurrence of risk situations for venous thrombosis and events (e.g. venous thrombosis, death). RESULTS Twenty-six of the 575 asymptomatic carriers (4.5%) and seven of the 1118 controls (0.6%) experienced a first deep venous thrombosis or pulmonary embolism during follow-up. Of these events, 58% occurred spontaneously in the carriers compared with 43% in the controls. The incidence of first events was 0.8% per year (95% CI 0.5-1.2) in the carriers compared with 0.1% per year (95% CI 0.0-0.2) in the controls. The highest incidence was associated with antithrombin deficiency or combined defects, and the lowest incidence with factor V Leiden. CONCLUSIONS The incidence of venous events in asymptomatic individuals from thrombophilic families does not exceed the risk of bleeding associated with long-term anticoagulant treatment in the literature (1-3%).
Collapse
|
45
|
Hormone replacement therapy and venous thromboembolism. Thromb Res 2005; 115 Suppl 1:88-92. [PMID: 15790166] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
|
46
|
Inherited thrombophilia. Vasc Med 2005; 9:219-21. [PMID: 15675188 DOI: 10.1191/1358863x04vm556xx] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
There is limited evidence that certain heritable thrombophilias may be associated with an increased risk of peripheral vascular disease. In particular, increased activated protein C resistance and FV Leiden have been described as being more prevalent in patients with peripheral arterial disease. There is no clear evidence at present, however, that other heritable thrombophilias are associated with an increased risk of arterial occlusive disease. Heritable thrombophilia, in particular FV Leiden, may be associated with an increased risk of vascular reconstruction failure but there is a lack of evidence to show that intervention with anticoagulants influences the outcome of graft surgery in these patients.
Collapse
|
47
|
Abstract
Preeclampsia is characterized by hypertension, dyslipidemia, and increased systemic inflammatory response and has been associated with an increased maternal risk of cardiovascular disease later in life. Low-grade chronic inflammation is a risk factor for cardiovascular disease. This study examined changes in inflammatory markers prospectively during pregnancy, the current inflammatory status of women who had a pregnancy complicated by preeclampsia 20 years previously against matched controls, and the association between inflammatory genes and risk of preeclampsia in a case (n=106) control (n=212) study. In control pregnancies (n=34), mean interleukin-10 (IL-10) levels increased 38% (
P
=0.012) and tumor necrosis factor-α (TNF-α) by 33% (
P
=0.024) between the first and third trimesters. The mean preeclampsia group IL-10 and TNF-α rose by 43% (
P
=0.013 and
P
=0.0065, respectively) from the first to the third trimester. In women with preeclampsia only, plasma IL-6 increased from the first to the third trimester (1.66 [2.04] to 2.94 [2.47] pg/mL;
P
=0.0004). Twenty years after the index pregnancy, women who had had preeclampsia demonstrated significantly higher IL-6 to IL-10 ratio (3.96 [6.07] versus 2.12 [1.89];
P
=0.034) compared with a healthy index pregnancy 20 years previously, that persisted after adjustment for smoking and current body mass index. The IL-1β (C-511T), IL-6 (G-174C), TNF-α (G-308A), E-selectin (S128R), intercellular adhesion molecule-1 (K469E), and C-reactive protein (C1059G) polymorphisms were not associated with risk of developing preeclampsia. In conclusion, preeclampsia is associated with short- and long-term changes in inflammatory status.
Collapse
|
48
|
Abstract
BACKGROUND We started a large multicenter prospective follow-up study to provide reliable risk estimates of venous thrombosis in families with various thrombophilic defects. OBJECTIVES This paper describes data collected at study entry on venous events experienced before study inclusion, i.e. the baseline data. PATIENTS/METHODS All individuals (probands, relatives) registered in nine European thrombosis centers with the factor (F)V Leiden mutation, a deficiency of antithrombin, protein C or protein S, or a combination of these defects, were enrolled between March 1994 and September 1997. As control individuals, partners, friends or acquaintances of the thrombophilic participants were included. Incidence and relative risk of objectively confirmed venous thrombotic events (VTEs) prior to entry were calculated for the relatives with thrombophilia and the controls. RESULTS Of the 846 relatives with thrombophilia (excluding probands), 139 (16%) had experienced a VTE with an incidence of 4.4 per 1000 person years. Of the controls, 15 of the 1212 (1%) controls had experienced a VTE with an incidence of 0.3 per 1000 person years. The risk of venous thrombosis associated with familial thrombophilia was 15.7 (95% CI 9.2-26.8) and remained similar after adjustment for regional and sex-effects (16.4; 95% CI 9.6-28.0). The highest incidence per 1000 person years was found in relatives with combined defects (8.4; 95% CI 5.6-12.2), and the lowest incidence was found in those with the FV Leiden mutation (1.5; 95% CI 0.8-2.6). CONCLUSIONS Considerable differences in the lifetime risk of VTE were observed among individuals with different thrombophilia defects.
Collapse
|
49
|
Abstract
BACKGROUND As the placental vessels are dependent on the normal balance of procoagulant and anticoagulant mechanisms, inherited thrombophilia may be associated with fetal loss. OBJECTIVES We performed a prospective study to investigate the relation between inherited thrombophilia and fetal loss, and the influence of thromboprophylaxis on pregnancy outcome. PATIENTS AND METHODS Women were enrolled in the European Prospective Cohort on Thrombophilia (EPCOT). These included women with factor (F)V Leiden or a deficiency of antithrombin, protein C or protein S. Controls were partners or acquaintances of thrombophilic individuals. A total of 191 women (131 with thrombophilia, 60 controls) had a pregnancy outcome during prospective follow-up. Risk of fetal loss and effect of thromboprophylaxis were estimated by frequency calculation and Cox regression modelling. RESULTS The risk of fetal loss appeared slightly increased in women with thrombophilia without a previous history of fetal loss who did not use any anticoagulants during pregnancy (7/39 vs. 7/51; relative risk 1.4; 95% confidence interval 0.4, 4.7). Per type of defect the relative risk varied only minimally from 1.4 for FV Leiden to 1.6 for antithrombin deficiency compared with control women. Prophylactic anticoagulant treatment during pregnancy in 83 women with thrombophilia differed greatly in type, dose and duration, precluding solid conclusions on the effect of thromboprophylaxis on fetal loss. No clear benefit of anticoagulant prophylaxis was apparent. CONCLUSIONS Women with thrombophilia appear to have an increased risk of fetal loss, although the likelihood of a positive outcome is high in both women with thrombophilia and in controls.
Collapse
|
50
|
Abstract
BACKGROUND AND OBJECTIVES The aim of this retrospective study was to assess the effect of activated recombinant factor VII (rFVIIa) on the natural history of massive transfusion episodes. MATERIALS AND METHODS During 2002, outcome parameters were assessed in 50 patients transfused with more than 10 units of packed red cells. The effect of the addition of rFVIIa in 10 patients, with intractable bleeding, was then observed. RESULTS Overall mortality was 20% at 24 h and 34% at 7 days. Severe coagulopathy was confirmed as a serious negative prognostic factor and occurred in 42% of patients overall, but in 70% of rFVIIa-treated patients. Transient cessation or reduction of bleeding was noted in 60% of patients following rFVIIa infusion. However, 24-h and 7-day mortality rates were 40% and 70%, respectively, in this group. CONCLUSIONS Last-ditch rFVIIa therapy in patients resistant to conventional treatment did not rescue these patients or significantly alter outcomes.
Collapse
|