1
|
Laboratory Detection and Initial Diagnosis of Monoclonal Gammopathies. Arch Pathol Lab Med 2022; 146:575-590. [PMID: 34347866 DOI: 10.5858/arpa.2020-0794-cp] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/30/2021] [Indexed: 11/06/2022]
Abstract
CONTEXT.— The process for identifying patients with monoclonal gammopathies is complex. Initial detection of a monoclonal immunoglobulin protein (M protein) in the serum or urine often requires compilation of analytical data from several areas of the laboratory. The detection of M proteins depends on adequacy of the sample provided, available clinical information, and the laboratory tests used. OBJECTIVE.— To develop an evidence-based guideline for the initial laboratory detection of M proteins. DESIGN.— To develop evidence-based recommendations, the College of American Pathologists convened a panel of experts in the diagnosis and treatment of monoclonal gammopathies and the laboratory procedures used for the initial detection of M proteins. The panel conducted a systematic literature review to address key questions. Using the Grading of Recommendations Assessment, Development, and Evaluation approach, recommendations were created based on the available evidence, strength of that evidence, and key judgements as defined in the Grading of Recommendations Assessment, Development, and Evaluation Evidence to Decision framework. RESULTS.— Nine guideline statements were established to optimize sample selection and testing for the initial detection and quantitative measurement of M proteins used to diagnose monoclonal gammopathies. CONCLUSIONS.— This guideline was constructed to harmonize and strengthen the initial detection of an M protein in patients displaying symptoms or laboratory features of a monoclonal gammopathy. It endorses more comprehensive initial testing when there is suspicion of amyloid light chain amyloidosis or neuropathies, such as POEMS (polyneuropathy, organomegaly, endocrinopathy, M protein, and skin changes) syndrome, associated with an M protein.
Collapse
|
2
|
Commentary on No Monoclonal Protein in a Patient with CRAB Features. Clin Chem 2021; 67:1589. [PMID: 34850842 DOI: 10.1093/clinchem/hvab211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2021] [Accepted: 08/10/2021] [Indexed: 11/13/2022]
|
3
|
Single-Dilution COVID-19 Antibody Test with Qualitative and Quantitative Readouts. mSphere 2021; 6:e00224-21. [PMID: 33883259 PMCID: PMC8546701 DOI: 10.1128/msphere.00224-21] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2021] [Accepted: 03/24/2021] [Indexed: 12/24/2022] Open
Abstract
The coronavirus disease 2019 (COVID-19) global pandemic caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) continues to place an immense burden on societies and health care systems. A key component of COVID-19 control efforts is serological testing to determine the community prevalence of SARS-CoV-2 exposure and quantify individual immune responses to prior SARS-CoV-2 infection or vaccination. Here, we describe a laboratory-developed antibody test that uses readily available research-grade reagents to detect SARS-CoV-2 exposure in patient blood samples with high sensitivity and specificity. We further show that this sensitive test affords the estimation of viral spike-specific IgG titers from a single sample measurement, thereby providing a simple and scalable method to measure the strength of an individual's immune response. The accuracy, adaptability, and cost-effectiveness of this test make it an excellent option for clinical deployment in the ongoing COVID-19 pandemic.IMPORTANCE Serological surveillance has become an important public health tool during the COVID-19 pandemic. Detection of protective antibodies and seroconversion after SARS-CoV-2 infection or vaccination can help guide patient care plans and public health policies. Serology tests can detect antibodies against past infections; consequently, they can help overcome the shortcomings of molecular tests, which can detect only active infections. This is important, especially when considering that many COVID-19 patients are asymptomatic. In this study, we describe an enzyme-linked immunosorbent assay (ELISA)-based qualitative and quantitative serology test developed to measure IgG and IgA antibodies against the SARS-CoV-2 spike glycoprotein. The test can be deployed using commonly available laboratory reagents and equipment and displays high specificity and sensitivity. Furthermore, we demonstrate that IgG titers in patient samples can be estimated from a single measurement, enabling the assay's use in high-throughput clinical environments.
Collapse
|
4
|
Development, clinical translation, and utility of a COVID-19 antibody test with qualitative and quantitative readouts. MEDRXIV : THE PREPRINT SERVER FOR HEALTH SCIENCES 2020:2020.09.10.20192187. [PMID: 32935116 PMCID: PMC7491531 DOI: 10.1101/2020.09.10.20192187] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
The COVID-19 global pandemic caused by severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) continues to place an immense burden on societies and healthcare systems. A key component of COVID-19 control efforts is serologic testing to determine the community prevalence of SARS-CoV-2 exposure and quantify individual immune responses to prior infection or vaccination. Here, we describe a laboratory-developed antibody test that uses readily available research-grade reagents to detect SARS-CoV-2 exposure in patient blood samples with high sensitivity and specificity. We further show that this test affords the estimation of viral spike-specific IgG titers from a single sample measurement, thereby providing a simple and scalable method to measure the strength of an individual's immune response. The accuracy, adaptability, and cost-effectiveness of this test makes it an excellent option for clinical deployment in the ongoing COVID-19 pandemic.
Collapse
|
5
|
Standardization of Free Thyroxine Measurements Allows the Adoption of a More Uniform Reference Interval. Clin Chem 2017; 63:1642-1652. [DOI: 10.1373/clinchem.2017.274407] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2017] [Accepted: 06/13/2017] [Indexed: 11/06/2022]
Abstract
Abstract
BACKGROUND
The IFCC Committee for Standardization of Thyroid Function Tests intended to standardize free thyroxine (FT4) immunoassays. We developed a Système International d'Unités traceable conventional reference measurement procedure (RMP) based on equilibrium dialysis and mass spectrometry. We describe here the latest studies intended to recalibrate against the RMP and supply a proof of concept, which should allow continued standardization efforts.
METHODS
We used the RMP to target the standardization and reference interval (RI) panels, which were also measured by 13 manufacturers. We validated the suitability of the recalibrated results to meet specifications for bias (3.3%) and total error (8.0%) determined from biological variation. However, because these specifications were stringent, we expanded them to 10% and 13%, respectively. The results for the RI panel were reported as if the assays were recalibrated. We estimated all but 1 RI using parametric statistical procedures and hypothesized that the RI determined by the RMP was suitable for use by the recalibrated assays.
RESULTS
Twelve of 13 recalibrated assays had a bias, meeting the 10% specification with 95% confidence; for 7 assays, this applied even for the 3.3% specification. Only 1 assay met the 13% total error specification. Recalibration reduced the CV of the assay means for the standardization panel from 13% to 5%. The proof-of-concept study confirmed our hypothesis regarding the RI but within constraints.
CONCLUSIONS
Recalibration to the RMP significantly reduced the FT4 immunoassays' bias, so that the RI determined by the RMP was suitable for common use within a margin of 12.5%.
Collapse
|
6
|
Harmonization of Serum Thyroid-Stimulating Hormone Measurements Paves the Way for the Adoption of a More Uniform Reference Interval. Clin Chem 2017; 63:1248-1260. [PMID: 28522444 DOI: 10.1373/clinchem.2016.269456] [Citation(s) in RCA: 53] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2016] [Accepted: 04/04/2017] [Indexed: 11/06/2022]
Abstract
BACKGROUND The IFCC Committee for Standardization of Thyroid Function Tests developed a global harmonization approach for thyroid-stimulating hormone measurements. It is based on a multiassay method comparison study with clinical serum samples and target setting with a robust factor analysis method. Here we describe the Phase IV method comparison and reference interval (RI) studies conducted with the objective to recalibrate the participating assays and demonstrate the proof-of-concept. METHODS Fourteen manufacturers measured the harmonization and RI panel; 4 of them quantified the harmonization and first follow-up panel in parallel. All recalibrated their assays to the statistically inferred targets. For validation, we used desirable specifications from the biological variation for the bias and total error (TE). The RI measurements were done with the assays' current calibrators, but data were also reported after transformation to the new calibration status. We estimated the pre- and postrecalibration RIs with a nonparametric bootstrap procedure. RESULTS After recalibration, 14 of 15 assays met the bias specification with 95% confidence; 8 assays complied with the TE specification. The CV of the assay means for the harmonization panel was reduced from 9.5% to 4.2%. The RI study showed improved uniformity after recalibration: the ranges (i.e., maximum differences) exhibited by the assay-specific 2.5th, 50th, and 97.5th percentile estimates were reduced from 0.27, 0.89, and 2.13 mIU/L to 0.12, 0.29, and 0.77 mIU/L. CONCLUSIONS We showed that harmonization increased the agreement of results from the participating immunoassays, and may allow them to adopt a more uniform RI in the future.
Collapse
|
7
|
Prevalence of Traditional and Reverse-Algorithm Syphilis Screening in Laboratory Practice: A Survey of Participants in the College of American Pathologists Syphilis Serology Proficiency Testing Program. Arch Pathol Lab Med 2016; 141:93-97. [PMID: 27763779 DOI: 10.5858/2016-0110-cp] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
CONTEXT -Syphilis serology screening in laboratory practice is evolving. Traditionally, the syphilis screening algorithm begins with a nontreponemal immunoassay, which is manually performed by a laboratory technologist. In contrast, the reverse algorithm begins with a treponemal immunoassay, which can be automated. The Centers for Disease Control and Prevention has recognized both approaches, but little is known about the current state of laboratory practice, which could impact test utilization and interpretation. OBJECTIVE -To assess the current state of laboratory practice for syphilis serologic screening. DESIGN -In August 2015, a voluntary questionnaire was sent to the 2360 laboratories that subscribe to the College of American Pathologists syphilis serology proficiency survey. RESULTS -Of the laboratories surveyed, 98% (2316 of 2360) returned the questionnaire, and about 83% (1911 of 2316) responded to at least some questions. Twenty-eight percent (378 of 1364) reported revision of their syphilis screening algorithm within the past 2 years, and 9% (170 of 1905) of laboratories anticipated changing their screening algorithm in the coming year. Sixty-three percent (1205 of 1911) reported using the traditional algorithm, 16% (304 of 1911) reported using the reverse algorithm, and 2.5% (47 of 1911) reported using both algorithms, whereas 9% (169 of 1911) reported not performing a reflex confirmation test. Of those performing the reverse algorithm, 74% (282 of 380) implemented a new testing platform when introducing the new algorithm. CONCLUSION -The majority of laboratories still perform the traditional algorithm, but a significant minority have implemented the reverse-screening algorithm. Although the nontreponemal immunologic response typically wanes after cure and becomes undetectable, treponemal immunoassays typically remain positive for life, and it is important for laboratorians and clinicians to consider these assay differences when implementing, using, and interpreting serologic syphilis screening algorithms.
Collapse
|
8
|
Abstract
Iodine is an essential component of thyroid hormone. Because thyroid hormone synthesis is affected by iodine deficiency on the one hand and by excess iodine intake on the other, thyroid function biomarkers may be useful for assessing iodine status and studying the effects of iodine supplementation. However, reference intervals for some of the most useful thyroid function biomarkers, including serum concentrations of thyroid-stimulating hormone (TSH), free thyroxine (FT4), and thyroglobulin, vary widely due to variability in the commercially available immunoassays for these tests. Recognizing the need for standardization of thyroid function testing, the International Federation of Clinical Chemistry and Laboratory Medicine established a working group, later restructured as the Committee for Standardization of Thyroid Function Tests, to examine its feasibility. The committee has established a conventional reference measurement procedure for FT4 and an approach to harmonization of results for TSH. Panels of single-donation human blood specimens that span the measuring interval of the immunoassays were used to assess the performance of commercially available immunoassays and form the basis for their recalibration. Recalibration of the manufacturers' methods for both FT4 and TSH has shown that the variability among immunoassays can be successfully eliminated for euthyroid individuals as well as for patients with thyroid disease. The committee is not investigating the standardization of thyroglobulin at the present time.
Collapse
|
9
|
For Immunoglobulin Light Chains, It's Time to Fly! Clin Chem 2016; 62:1293-5. [PMID: 27509910 DOI: 10.1373/clinchem.2016.261933] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2016] [Accepted: 07/28/2016] [Indexed: 11/06/2022]
|
10
|
Standardization of FT4 and Harmonization of TSH Measurements--A Request for Input from Endocrinologists and Other Physicians. Endocr Pract 2016; 22:374. [PMID: 26937820 DOI: 10.4158/1934-2403-22.3.374] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
11
|
Laboratory Diagnosis of Celiac Disease in Patients with Selective IgA Deficiency. J Appl Lab Med 2016; 1:83-87. [PMID: 33626802 DOI: 10.1373/jalm.2016.020255] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2016] [Accepted: 04/25/2016] [Indexed: 11/06/2022]
|
12
|
Standardization of FT4 and harmonization of TSH measurements - a request for input from endocrinologists and other physicians. Clin Endocrinol (Oxf) 2016. [PMID: 26201824 DOI: 10.1111/cen.12861] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
13
|
Rapid Measurement of Cyclosporine and Sirolimus in Whole Blood by Paper Spray–Tandem Mass Spectrometry. Clin Chem 2016; 62:295-7. [DOI: 10.1373/clinchem.2015.245191] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
14
|
Standardization of FT4 and harmonization of TSH measurements: a request for input from endocrinologists and other physicians. Endocrine 2015; 50:826-7. [PMID: 26429779 DOI: 10.1007/s12020-015-0752-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/02/2015] [Accepted: 09/19/2015] [Indexed: 10/23/2022]
|
15
|
Standardization of Free T4 and Harmonization of TSH Measurements: A Request for Input from Endocrinologists and Other Physicians. Eur Thyroid J 2015; 4:271-2. [PMID: 26835432 PMCID: PMC4716420 DOI: 10.1159/000440614] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/03/2015] [Revised: 08/21/2015] [Indexed: 11/19/2022] Open
|
16
|
Standardization of Free Thyroxine and Harmonization of Thyrotropin Measurements: A Request for Input from Endocrinologists and Other Physicians. Thyroid 2015; 25:1379-80. [PMID: 26413772 PMCID: PMC4684666 DOI: 10.1089/thy.2015.0309] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
17
|
Standardization of FT4 and Harmonization of TSH Measurements--A Request for Input from Endocrinologists and Other Physicians. Exp Clin Endocrinol Diabetes 2015; 124:61-2. [PMID: 26372848 DOI: 10.1055/s-0035-1564102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
18
|
Standardization of FT4 and harmonization of TSH measurements - a request for input from endocrinologists and other physicians. Endocr J 2015. [PMID: 26211473 DOI: 10.1507/endocrj.ej15-0382] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Given the prevalence of thyroid disorders and the subtle signs and symptoms that may accompany subclinical disease, reliable laboratory testing for serum TSH and free thyroid hormones is important for both primary care physicians and endocrinologists. The laboratory community has recognized the need for standardization of thyroid function tests to achieve comparability of measurement results between methods. This applies in particular to tests for free T4 (FT4), which may be considered controversial in terms of clinical and analytical validity. However, variability is also observed with TSH testing - a fact which has not been emphasized in ongoing discussions regarding lowering the upper limit of normal and/or common decision limits to start treatment for hypothyroidism. In response to this need, the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Committee for Standardization of Thyroid Function Tests worked over the years towards the goal of standardization of FT4 and TSH testing.
Collapse
|
19
|
|
20
|
A Progress Report of the IFCC Committee for Standardization of Thyroid Function Tests. Eur Thyroid J 2014; 3:109-16. [PMID: 25114874 PMCID: PMC4109515 DOI: 10.1159/000358270] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/05/2013] [Revised: 12/30/2013] [Indexed: 01/24/2023] Open
Abstract
BACKGROUND The IFCC Committee for Standardization of Thyroid Function Tests aims at equivalence of laboratory test results for free thyroxine (FT4) and thyrotropin (TSH). OBJECTIVES This report describes the phase III method comparison study with clinical samples representing a broad spectrum of thyroid disease. The objective was to expand the feasibility work and explore the impact of standardization/harmonization in the clinically relevant concentration range. METHODS Two sets of serum samples (74 for FT4, 94 for TSH) were obtained in a clinical setting. Eight manufacturers participated in the study (with 13 FT4 and 14 TSH assays). Targets for FT4 were set by the international conventional reference measurement procedure of the IFCC; those for TSH were based on the all-procedure trimmed mean. The manufacturers recalibrated their assays against these targets. RESULTS All FT4 assays were negatively biased in the mid- to high concentration range, with a maximum interassay discrepancy of approximately 30%. However, in the low range, the maximum deviation was approximately 90%. For TSH, interassay comparability was reasonable in the mid-concentration range, but worse in the pathophysiological ranges. Recalibration was able to eliminate the interassay differences, so that the remaining dispersion of the data was nearly entirely due to within-assay random error components. The impact of recalibration on the numerical results was particularly high for FT4. CONCLUSIONS Standardization and harmonization of FT4 and TSH measurements is feasible from a technical point of view. Because of the impact on the numerical values, the implementation needs careful preparation with the stakeholders.
Collapse
|
21
|
Abstract
The free hormone hypothesis states that a hormone's physiological effects depend on the free hormone concentration, not the total hormone concentration. Although the in vivo relationship between free hormone and protein-bound hormone is complex, most experts have applied this view to the design of assays used to assess the free hormone concentration in the blood sampled for testing in vitro. The history of the measurement of free thyroxine, probably the most frequently requested free hormone determination, offers a good example of the approaches that have been taken. Methods that require physical separation of the free hormone from the protein-bound hormone must address both the potential disturbance in the equilibrium between the two, as well as the challenge of quantifying small levels of hormone accurately and precisely. The implementation of mass spectrometry in the clinical laboratory has helped to develop proposed reference measurement procedures. These must be utilized to standardize the variety of immunoassay approaches that currently represent options commercially available to the routine clinical laboratory. Practicing endocrinologists should discuss the details of the free hormone assays offered by the clinical laboratory they utilize for patient result reporting, and clinical laboratories should implement the recommendations of published guidelines to ensure that free hormone results using commercially available immunoassays are as accurate and precise as possible.
Collapse
|
22
|
Abstract
Sepsis is an unusual systemic reaction to what is sometimes an otherwise ordinary infection, and it probably represents a pattern of response by the immune system to injury. A hyper-inflammatory response is followed by an immunosuppressive phase during which multiple organ dysfunction is present and the patient is susceptible to nosocomial infection. Biomarkers to diagnose sepsis may allow early intervention which, although primarily supportive, can reduce the risk of death. Although lactate is currently the most commonly used biomarker to identify sepsis, other biomarkers may help to enhance lactate’s effectiveness; these include markers of the hyper-inflammatory phase of sepsis, such as pro-inflammatory cytokines and chemokines; proteins such as C-reactive protein and procalcitonin which are synthesized in response to infection and inflammation; and markers of neutrophil and monocyte activation. Recently, markers of the immunosuppressive phase of sepsis, such as anti-inflammatory cytokines, and alterations of the cell surface markers of monocytes and lymphocytes have been examined. Combinations of pro- and anti-inflammatory biomarkers in a multi-marker panel may help identify patients who are developing severe sepsis before organ dysfunction has advanced too far. Combined with innovative approaches to treatment that target the immunosuppressive phase, these biomarkers may help to reduce the mortality rate associated with severe sepsis which, despite advances in supportive measures, remains high.
Collapse
|
23
|
Commentary. Clin Chem 2011; 57:1649. [PMID: 22125319 DOI: 10.1373/clinchem.2011.167445] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
24
|
Abstract
The increased incidence of sepsis, a systemic response to infection that occurs in some patients, has stimulated interest in identifying infected patients who are at risk and intervening early. When this condition progresses to severe sepsis (characterized by organ dysfunction), mortality is high. Hospitals that have implemented recommendations of the Surviving Sepsis Campaign have seen a reduction in mortality rate for hospital-acquired severe sepsis. They may reduce this further by focusing on new approaches to diagnosing sepsis, especially at an early stage. Sepsis is a complicated syndrome with many physiological derangements and many emerging laboratory markers of sepsis have been proposed as adjuncts to clinical evaluation. The list includes cytokines, acute phase proteins, neutrophil activation markers, markers of abnormal coagulation and, recently, markers of suppression of both the innate and adaptive immune response. The perfect biomarker would accurately identify patients at risk of developing severe sepsis and then guide targeted therapy.
Collapse
|
25
|
Report of the IFCC Working Group for Standardization of Thyroid Function Tests; part 1: thyroid-stimulating hormone. Clin Chem 2010; 56:902-11. [PMID: 20395624 DOI: 10.1373/clinchem.2009.140178] [Citation(s) in RCA: 86] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND Laboratory testing of serum thyroid-stimulating hormone (TSH) is an essential tool for the diagnosis and management of various thyroid disorders whose collective prevalence lies between 4% and 8%. However, between-assay discrepancies in TSH results limit the application of clinical practice guidelines. METHODS We performed a method comparison study with 40 sera to assess the result comparability and performance attributes of 16 immunoassays. RESULTS Thirteen of 16 assays gave mean results within 10% of the overall mean. The difference between the most extreme means was 39%. Assay-specific biases could be eliminated by recalibration to the overall mean. After recalibration of singlicate results, all assays showed results within the biological total error goal (22.8%), except for 1 result in each of 4 assays. For a sample with a TSH concentration of 0.016 mIU/L, 6 assays either did not report results or demonstrated CVs >20%. Within-run and total imprecision ranged from 1.5% to 5.5% and 2.5% to 7.7%, respectively. Most assays were able to match the internal QC targets within 5%. Within-run drifts and shifts were observed. CONCLUSIONS Harmonization of TSH measurements would be particularly beneficial for 3 of the 16 examined assays. These data demonstrate that harmonization may be accomplished by establishing calibration traceability to the overall mean values for a panel of patient samples. However, the full impact of the approach must be further explored with a wider range of samples. Although a majority of assays showed excellent quality of performance, some would benefit from improved within-run stability.
Collapse
|
26
|
Report of the IFCC Working Group for Standardization of Thyroid Function Tests; part 2: free thyroxine and free triiodothyronine. Clin Chem 2010; 56:912-20. [PMID: 20395623 DOI: 10.1373/clinchem.2009.140194] [Citation(s) in RCA: 92] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND Free thyroxine (FT4) and free triiodothyronine (FT3) measurements are useful in the diagnosis and treatment of a variety of thyroid disorders. The IFCC Scientific Division established a Working Group to resolve issues of method performance to meet clinical requirements. METHODS We compared results for measurement of a panel of single donor sera using clinical laboratory procedures based on equilibrium dialysis-isotope dilution-mass spectrometry (ED-ID-MS) (2 for FT4, 1 for FT3) and immunoassays from 9 manufacturers (15 for FT4, 13 for FT3) to a candidate international conventional reference measurement procedure (cRMP) also based on ED-ID-MS. RESULTS For FT4 (FT3), the mean bias of 2 (4) assays was within 10% of the cRMP, whereas for 15 (9) assays, negative biases up to -42% (-30%) were seen; 1 FT3 assay was positively biased by +22%. Recalibration to the cRMP eliminated assay-specific biases; however, sample-related effects remained, as judged from difference plots with biologic total error limits. Correlation coefficients to the cRMPs ranged for FT4 (FT3) from 0.92 to 0.78 (0.88 to 0.30). Within-run and total imprecision ranged for FT4 (FT3) from 1.0% to 11.1% (1.8% to 9.4%) and 1.5% to 14.1% (2.4% to 10.0%), respectively. Approximately half of the manufacturers matched the internal QC targets within approximately 5%; however, within-run instability was observed. CONCLUSIONS The study showed that most assays had bias largely correctable by establishing calibration traceability to a cRMP and that the majority performed well. Some assays, however, would benefit from improved precision, within-run stability, and between-run consistency.
Collapse
|
27
|
Rapid blood separation is superior to fluoride for preventing in vitro reductions in measured blood glucose concentration. J Clin Pathol 2009; 62:752-3. [DOI: 10.1136/jcp.2008.062547] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
28
|
Using procalcitonin to diagnose sepsis and the potential for improved antibiotic stewardship. MLO: MEDICAL LABORATORY OBSERVER 2008; 40:25-26. [PMID: 19065938] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
|
29
|
Neurotensin increases mortality and mast cells reduce neurotensin levels in a mouse model of sepsis. Nat Med 2008; 14:392-8. [PMID: 18376408 DOI: 10.1038/nm1738] [Citation(s) in RCA: 97] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2008] [Accepted: 02/14/2008] [Indexed: 11/09/2022]
Abstract
Sepsis is a complex, incompletely understood and often fatal disorder, typically accompanied by hypotension, that is considered to represent a dysregulated host response to infection. Neurotensin (NT) is a 13-amino-acid peptide that, among its multiple effects, induces hypotension. We find that intraperitoneal and plasma concentrations of NT are increased in mice after severe cecal ligation and puncture (CLP), a model of sepsis, and that mice treated with a pharmacological antagonist of NT, or NT-deficient mice, show reduced mortality during severe CLP. In mice, mast cells can degrade NT and reduce NT-induced hypotension and CLP-associated mortality, and optimal expression of these effects requires mast cell expression of neurotensin receptor 1 and neurolysin. These findings show that NT contributes to sepsis-related mortality in mice during severe CLP and that mast cells can lower NT concentrations, and suggest that mast cell-dependent reduction in NT levels contributes to the ability of mast cells to enhance survival after CLP.
Collapse
|
30
|
Proposal of a candidate international conventional reference measurement procedure for free thyroxine in serum. Clin Chem Lab Med 2007; 45:934-6. [PMID: 17617044 DOI: 10.1515/cclm.2007.155] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
In the present paper the IFCC WG-STFT recommends and provides the rationale to establish metrological traceability of serum free thyroxine (FT4) measurements to a candidate international conventional reference measurement procedure. It is proposed that this procedure be based on equilibrium dialysis combined with determination of thyroxine in the dialysate with a trueness-based reference measurement procedure. The measurand is thus operationally defined as "thyroxine in the dialysate from equilibrium dialysis of serum prepared under defined conditions". With regard to the trueness-based reference measurement procedure, the WG-STFT recommends use of an isotope dilution-liquid chromatography/tandem mass spectrometry (ID-LC/tandem MS) procedure for total thyroxine that has been optimized towards measurement at picomolar concentration levels and that is listed in the database of the Joint Committee for Traceability in Laboratory Medicine (JCTLM). For calibration, the purified thyroxine material IRMM-468 (resulting from a project funded by the European Commission and recently submitted to the JCTLM) is proposed. The WG-STFT stresses that according to this recommendation it is a prerequisite to strictly adhere to the defined equilibrium dialysis procedure, whereas it is permissible to introduce variants in the ID-LC/tandem MS procedure.
Collapse
|
31
|
Lymphoplasmacytic lymphoma arising in the setting of hepatitis C and mixed cryoglobulinemia. J Clin Oncol 2007; 25:4312-4. [PMID: 17878484 DOI: 10.1200/jco.2007.12.8876] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
32
|
Measurement of free thyroxine in laboratory medicine--proposal of measurand definition. Clin Chem Lab Med 2007; 45:563-4. [PMID: 17439341 DOI: 10.1515/cclm.2007.099] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
33
|
A noninvasive approach for assessing tumor hypoxia in xenografts: developing a urinary marker for hypoxia. Cancer Res 2005; 65:6151-8. [PMID: 16024616 DOI: 10.1158/0008-5472.can-04-2602] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Tumor hypoxia modifies the efficacy of conventional anticancer therapy and promotes malignant tumor progression. Human chorionic gonadotropin (hCG) is a glycoprotein secreted during pregnancy that has been used to monitor tumor burden in xenografts engineered to express this marker. We adapted this approach to use urinary beta-hCG as a secreted reporter protein for tumor hypoxia. We used a hypoxia-inducible promoter containing five tandem repeats of the hypoxia-response element (HRE) ligated upstream of the beta-hCG gene. This construct was stably integrated into two different cancer cell lines, FaDu, a human head and neck squamous cell carcinoma, and RKO, a human colorectal cancer cell line. In vitro studies showed that tumor cells stably transfected with this plasmid construct secrete beta-hCG in response to hypoxia or hypoxia-inducible factor 1alpha (HIF-1alpha) stabilizing agents. The hypoxia responsiveness of this construct can be blocked by treatment with agents that affect the HIF-1alpha pathways, including topotecan, 1-benzyl-3-(5'-hydroxymethyl-2'-furyl)indazole (YC-1), and flavopiridol. Immunofluorescent analysis of tumor sections and quantitative assessment with flow cytometry indicate colocalization between beta-hCG and 2-(2-nitro-1H-imidazol-1-yl)-N-(2,2,3,3,3-pentafluoropropyl)acetamide (EF5) and beta-hCG and pimonidazole, two extrinsic markers for tumor hypoxia. Secretion of beta-hCG from xenografts that contain these stable constructs is directly responsive to changes in tumor oxygenation, including exposure of the animals to 10% O2 and tumor bed irradiation. Similarly, urinary beta-hCG levels decline after treatment with flavopiridol, an inhibitor of HIF-1 transactivation. This effect was observed only in tumor cells expressing a HRE-regulated reporter gene and not in tumor cells expressing a cytomegalovirus-regulated reporter gene. The 5HRE beta-hCG reporter system described here enables serial, noninvasive monitoring of tumor hypoxia in a mouse model by measuring a urinary reporter protein.
Collapse
MESH Headings
- Animals
- Carcinoma, Squamous Cell/drug therapy
- Carcinoma, Squamous Cell/genetics
- Carcinoma, Squamous Cell/metabolism
- Carcinoma, Squamous Cell/urine
- Cell Hypoxia/physiology
- Cell Line, Tumor
- Chorionic Gonadotropin, beta Subunit, Human/genetics
- Chorionic Gonadotropin, beta Subunit, Human/urine
- Colorectal Neoplasms/drug therapy
- Colorectal Neoplasms/genetics
- Colorectal Neoplasms/metabolism
- Colorectal Neoplasms/urine
- DNA-Binding Proteins/genetics
- Flavonoids/pharmacology
- Genes, Reporter/genetics
- Genetic Vectors/genetics
- Head and Neck Neoplasms/drug therapy
- Head and Neck Neoplasms/genetics
- Head and Neck Neoplasms/metabolism
- Head and Neck Neoplasms/urine
- Humans
- Hypoxia-Inducible Factor 1
- Hypoxia-Inducible Factor 1, alpha Subunit
- Mice
- Mice, Inbred BALB C
- Mice, Inbred SENCAR
- Neoplasm Transplantation
- Nuclear Proteins/genetics
- Piperidines/pharmacology
- Topotecan/pharmacology
- Transcription Factors/genetics
- Transfection
- Transplantation, Heterologous
Collapse
|
34
|
|
35
|
Abstract
OBJECTIVES To test the hypothesis that thyroglobulin (Tg) and free T4 (FT4) concentrations more than 2SD from the control mean are not increased in pregnancy in an iodine replete area in the absence of elevated TSH concentrations. The second hypothesis to be tested was that if such abnormalities in FT4 and Tg in the absence of elevated TSH concentrations were to exist they would not be associated with lowered IQs in the progeny. DESIGN Cross-sectional study in New England comparing TSH, Tg, antibodies to Tg and FT4 in volunteer nonpregnant women 20-40 years old with those in hypothyroid mothers and matched euthyroid control mothers. The results are contrasted with those from similar studies reported from iodine deficient areas. SUBJECTS Sera obtained at 17 weeks gestation and stored at -20 degrees C for 8 years were retrieved and analysed from 62 mothers with subclinical hypothyroidism and 124 matched euthyroid mothers. The diagnosis of hypothyroidism was made by finding a TSH concentration > 97.7 percentiile for 25 000 consecutive pregnant women. Sera were also analysed from 53 healthy nonpregnant volunteer women aged 20-40 years. MEASUREMENTS TSH, Tg and Tg antibodies were measured in the sera of the nonpregnant volunteers, and Tg and Tg antibodies in the sera of the pregnant women who had previously been analysed for TSH and FT4. The incidence of FT4 concentrations below the 2.3 percentile of nonpregnant laboratory controls was compared for the euthyroid and hypothyroid mothers and the laboratory normal controls. RESULTS Thirty-one per cent of the 62 hypothyroid mothers had FT4 concentrations below the 2.3 percentile compared with only one (0.8%) of the euthyroid mothers. Mean Tg concentrations did not differ between the nonpregnant controls and the euthyroid pregnant women, 14 +/- 10 vs. 16 +/- 10 micro g/l. Tg concentration in the hypothyroid mothers was 44 +/- 61, significantly greater than for either of the euthyroid control groups, P < 0.005. Positive antibodies to Tg were found in 9% and 10% of the control groups and 57% of the hypothyroid mothers, P < 0.0005. When TSH is included as an independent variable in multiple linear and logistic regressions, FT4 and Tg no longer correlate significantly with IQs. CONCLUSIONS The incidences of FT4 concentrations more than 2SD below the control mean and of Tg > 2SD above the control mean are significantly increased in hypothyroid mothers in iodlne-sufficient New England. However, in the absence of elevated TSH concentrations, the incidences of such abnormalities in FT4 and TG are negligible. Indeed, concentrations for FT4, Tg and Tg antibodies for nonpregnant and pregnant controls in our iodine-replete area do not differ significantly from each other or from previously reported normative concentrations with the methods used. Thus, pregnancy in New England neither increases Tg nor lowers FT4 concentrations.
Collapse
|
36
|
Maternal thyroid deficiency and pregnancy complications: implications for population screening. J Med Screen 2001; 7:127-30. [PMID: 11126160 DOI: 10.1136/jms.7.3.127] [Citation(s) in RCA: 339] [Impact Index Per Article: 14.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
OBJECTIVE To examine the relation between certain pregnancy complications and thyroid stimulating hormone (TSH) measurements in a cohort of pregnant women. METHODS TSH was measured in sera obtained from women during the second trimester as part of routine prenatal care. Information was then collected about vaginal bleeding, premature delivery, low birthweight, abruptio placentae, pregnancy induced hypertension, need for cesarean section, low Apgar scores, and fetal and neonatal death. RESULTS Among 9403 women with singleton pregnancies, TSH measurements were 6 mU/l or greater in 209 (2.2%). The rate of fetal death was significantly higher in those pregnancies (3.8%) than in the women with TSH less than 6 mU/l (0.9%, odds ratio 4.4, 95% confidence interval 1.9-9.5). Other pregnancy complications did not occur more frequently. CONCLUSION From the second trimester onward, the major adverse obstetrical outcome associated with raised TSH in the general population is an increased rate of fetal death. If thyroid replacement treatment avoided this problem this would be another reason to consider population screening.
Collapse
|
37
|
Interpretation of Diagnostic Tests, Seventh Edition. Jacques Wallach. Philadelphia, PA: Lippincott Williams & Wilkins, 2000, 1026 pp., $49.95. ISBN 0-7817-1659-4. Clin Chem 2001. [DOI: 10.1093/clinchem/47.2.359] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
38
|
Abstract
BACKGROUND When thyroid deficiency occurs simultaneously in a pregnant woman and her fetus, the child's neuropsychological development is adversely affected. Whether developmental problems occur when only the mother has hypothyroidism during pregnancy is not known. METHODS In 1996 and 1997, we measured thyrotropin in stored serum samples collected from 25,216 pregnant women between January 1987 and March 1990. We then located 47 women with serum thyrotropin concentrations at or above the 99.7th percentile of the values for all the pregnant women, 15 women with values between the 98th and 99.6th percentiles, inclusive, in combination with low thyroxine levels, and 124 matched women with normal values. Their seven-to-nine-year-old children, none of whom had hypothyroidism as newborns, underwent 15 tests relating to intelligence, attention, language, reading ability, school performance, and visual-motor performance. RESULTS The children of the 62 women with high serum thyrotropin concentrations performed slightly less well on all 15 tests. Their full-scale IQ scores on the Wechsler Intelligence Scale for Children, third edition, averaged 4 points lower than those of the children of the 124 matched control women (P= 0.06); 15 percent had scores of 85 or less, as compared with 5 percent of the matched control children. Of the 62 women with thyroid deficiency, 48 were not treated for the condition during the pregnancy under study. The full-scale IQ scores of their children averaged 7 points lower than those of the 124 matched control children (P=0.005); 19 percent had scores of 85 or less. Eleven years after the pregnancy under study, 64 percent of the untreated women and 4 percent of the matched control women had confirmed hypothyroidism. CONCLUSIONS Undiagnosed hypothyroidism in pregnant women may adversely affect their fetuses; therefore, screening for thyroid deficiency during pregnancy may be warranted.
Collapse
|
39
|
Abstract
OBJECTIVES The purpose of this study was to test the hypothesis that low circulating thyroxine concentrations characteristic of very low birth weight (VLBW) neonates (< 1500 g) are the result of decreased protein binding of thyroid hormones and to elucidate the mechanism(s) responsible and possible significance thereof. DESIGN Cross-sectional comparison of thyroid related measurements in cord blood specimens from VLBW infants and from full term infants. Longitudinal comparison in cord and 2- and 4-week blood specimens from VLBW infants. PATIENTS Cord blood specimens were analysed from 47 VLBW and 45 full term infants weighing > or = 2500 g. Repeat analyses in venous bloods from 32 of the VLBW infants were analysed at 2 weeks of age and again at 4 weeks in 23. The first cohort of patients was studied in 1994 and comprised 28 VLBW and 24 full term infants (Cohort A). The studies were repeated in 1995-96 in 19 VLBW infants and 21 full term infants (Cohort B). MEASUREMENTS T4, free T4 (FT4), T3, thyroxine binding globulin (TBG), and TSH were measured in cord blood and 2- and 4-week venous specimens from VLBW infants and in cord blood specimens of full term infants. Molar ratios of T4/TBG were calculated. RESULTS (1) Cord blood TBG, T4 and T3 concentrations of VLBW infants were each 60% of those of term infants. TBG concentrations were 397 +/- 111 vs 680 +/- 172 nmol/l (P < 0.0005). T4 concentrations were 76 +/- 22 vs 139 +/- 26 nmol/l (P < 0.0005). FT4 concentrations were in the normal adult range in both neonatal groups. T4/TBG ratios did not differ between the neonatal groups but were significantly less than that of adults (P < 0.001). (2) TSH concentrations in VLBW infants at 2 and 4 weeks were less than 50% of cord blood values. At 2 weeks, TBG concentrations of VLBW infants were unchanged from cord blood concentrations but mean T4 concentration fell by 18% and T4/TBG ratios by 21% (P < 0.005). Mean FT4 rose by 78% (P < 0.02). The changes in mean T4 and FT4 were due largely to FT4 concentrations of 37-113 pmol/l and T4 concentrations of 13-48 nmol/l in 5 infants. These infants also had lower T4/TBG ratios and were smaller and more ill than the remainder of the cohort. The changes disappeared by 4 weeks in 3 of the 4 infants tested. CONCLUSIONS Cord T4/TBG ratios are the same in very low birth weight and term infants and are significantly lower than in adult blood. These are more than compensated for in term infants by a 236% increase in thyroxine binding globulin concentrations. The lower thyroxine binding globulin concentrations in very low birth weight infants explain their much lower T4 concentrations. Cord FT4 concentrations of full term and very low birth weight infants are in the normal adult range. T4 concentrations are further depressed and free T4 concentrations elevated in the most ill very low birth weight infants at 2 weeks of age in a manner analogous to that of the 'sick euthyroid syndrome'.
Collapse
|
40
|
Strong expression of vascular permeability factor (vascular endothelial growth factor) and its receptors in ovarian borderline and malignant neoplasms. J Transl Med 1996; 74:1105-15. [PMID: 8667614] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
Angiogenesis is a critical factor in the growth, progression, and metastatic spread of solid tumors. Furthermore, angiogenesis has been correlated with prognosis in patients with ovarian cancer. The pathogenesis of the angiogenic events in ovarian cancer, however, are not well defined. Vascular permeability factor/vascular endothelial growth factor (VPF/VEGF) is a multifunctional cytokine that has been shown to be an important regulator of tumor angiogenesis. The purpose of the present study was to define the expression of VPF/VEGF and its receptors flt-1 and KDR in ovarian tumors. Four specimens of normal ovarian cortex and 41 specimens of benign (4), borderline (8), and malignant (29) ovarian tumors were studied by in situ hybridization, and in some cases by immunohistochemical analysis. VPF/VEGF protein was also determined by an immunofluorometric assay in cyst fluids obtained from 11 patients, including 7 benign, 2 borderline, and 2 malignant tumors. VPF/VEGF mRNA and protein were expressed by the neoplastic cells in all of the malignant tumors evaluated, with the majority of tumors (28 of 29) showing strong expression of mRNA. Serous borderline tumors had variable VPF/VEGF mRNA expression, with two of six cases showing focal strong expression and four showing low-level expression. No definite expression of VPF/VEGF was seen in two cases of mucinous borderline tumors. No strong expression of VPF/VEGF mRNA was observed in normal ovarian cortex, including surface epithelium, or benign tumors. Substantially higher VPF protein concentrations were detected in cyst fluids of the two malignant (60, 440 pM) and two borderline tumors (210, 590 pM) than in the seven benign serous cysts (mean, 10 +/- 3 pM). In addition, microvascular endothelial cells strongly expressed mRNA of the VPF/VEGF receptors flt-1 and KDR and immunostained for VPF/VEGF protein in the majority of malignant and borderline tumors examined. These findings suggest that VPF/VEGF plays an important role in the angiogenesis associated with ovarian neoplasms.
Collapse
|
41
|
More on magnum automated T-uptake assay. Clin Chem 1996; 42:342. [PMID: 8595743] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
|
42
|
More on magnum automated T-uptake assay. Clin Chem 1996. [DOI: 10.1093/clinchem/42.2.342] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
43
|
Indirect estimation of thyroid hormone-binding proteins to calculate free thyroxine index: comparison of nonisotopic methods that use labeled thyroxine ("T-uptake"). Clin Chem 1995; 41:41-7. [PMID: 7813079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
There are many alternative ways of estimating free thyroxine (T4) when thyrotropin screening results are abnormal. In addition to free T4 immunoassays, the menu of most automated immunoassay instruments includes a nonisotopic version of the original triiodothyronine (T3)-uptake assay called "T-uptake." We evaluated the ability of five such assays (Access, ES-300, IMx, Magnum Opus, and Stratus) to accurately estimate the free thyroxine index (FTI) in euthyroid, hyperthyroid, and hypothyroid patients with abnormal concentrations of thyroid hormone-binding proteins, and in patients with nonthyroidal illness. For comparison, we calculated a similar FTI, using either T3-uptake or direct measurement of thyroxine-binding globulin (TBG). Euthyroid reference ranges were comparable. Of euthyroid patients with increased TBG, 12-32% and 5-20% had increased or suppressed FTI, respectively, depending on the T-uptake method used. Except for IMx, 6-35% of hypothyroid patients with increased TBG had inappropriately increased FTI. Patients with nonthyroidal illness had comparable results regardless of the method used, and T-uptake methods were variably affected by known inhibitors of thyroid hormone binding. The most reliable T-uptake method appeared to be the IMx, which, despite claims that it measures all thyroid hormone-binding proteins, correlated best with TBG concentrations.
Collapse
|
44
|
Indirect estimation of thyroid hormone-binding proteins to calculate free thyroxine index: comparison of nonisotopic methods that use labeled thyroxine ("T-uptake"). Clin Chem 1995. [DOI: 10.1093/clinchem/41.1.41] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
Abstract
There are many alternative ways of estimating free thyroxine (T4) when thyrotropin screening results are abnormal. In addition to free T4 immunoassays, the menu of most automated immunoassay instruments includes a nonisotopic version of the original triiodothyronine (T3)-uptake assay called "T-uptake." We evaluated the ability of five such assays (Access, ES-300, IMx, Magnum Opus, and Stratus) to accurately estimate the free thyroxine index (FTI) in euthyroid, hyperthyroid, and hypothyroid patients with abnormal concentrations of thyroid hormone-binding proteins, and in patients with nonthyroidal illness. For comparison, we calculated a similar FTI, using either T3-uptake or direct measurement of thyroxine-binding globulin (TBG). Euthyroid reference ranges were comparable. Of euthyroid patients with increased TBG, 12-32% and 5-20% had increased or suppressed FTI, respectively, depending on the T-uptake method used. Except for IMx, 6-35% of hypothyroid patients with increased TBG had inappropriately increased FTI. Patients with nonthyroidal illness had comparable results regardless of the method used, and T-uptake methods were variably affected by known inhibitors of thyroid hormone binding. The most reliable T-uptake method appeared to be the IMx, which, despite claims that it measures all thyroid hormone-binding proteins, correlated best with TBG concentrations.
Collapse
|
45
|
Distinguishing hypothyroxinemia due to euthyroid sick syndrome from pituitary insufficiency. ISRAEL JOURNAL OF MEDICAL SCIENCES 1994; 30:746-50. [PMID: 7960686] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Patients with severe nonthyroidal illness may have low serum levels of thyroid hormone and thyroid-stimulating hormone (TSH) indistinguishable from levels in patients with pituitary insufficiency. It is often difficult prospectively to rule out pituitary insufficiency in these patients. Our hypothesis was that patients sufficiently ill to have low free thyroxine index (FT4I) and TSH from nonthyroidal illness (euthyroid sick syndrome, or ESS) would have serum cortisol levels high enough to make pituitary insufficiency unlikely. Serum samples from all patients admitted to the Intensive Care Unit during 2 months were screened for low FT4I, and cortisol levels were measured on those samples. Five of five patients with a diagnosis of ESS had unequivocal elevations of serum cortisol (> 525 nmol/l), arguing against a diagnosis of pituitary insufficiency. Secondary hypothyroidism due to pituitary insufficiency can often be ruled out in patients with severe ESS by documenting appropriate elevated levels of serum cortisol.
Collapse
|
46
|
Abstract
Abstract
A clinically euthyroid 53-year-old woman with an IgA-lambda-secreting multiple myeloma presented with increased serum concentrations of thyroid hormones. Laboratory studies revealed increased total thyroxine (T4) and triiodothyronine (T3) concentrations, a high-normal free T4 concentration, and a normal basal thyrotropin (TSH) concentration with a normal response to thyroliberin (TRH). Her serum concentration of IgA was 11,040 mg/L (normal range 900-4500 mg/L) and immunoelectrophoresis revealed it to be monoclonal. This monoclonal IgA bound both T4 and T3, as determined by serum immunoelectrophoresis and direct binding studies. Immunoelectrophoresis in the presence of [125I]T4 or [125I]T3 localized the radiolabeled iodothyronines to a band corresponding exactly to the precipitin arc of the monoclonal IgA. We performed direct binding studies with IgA purified by affinity chromatography with the lectin jacalin. Purified IgA (50 micrograms) bound both [125I]T4 (12.3%) and [125I]T3 (2.7%) specifically and in a dose-dependent manner. Scatchard analysis of competitive-binding data utilizing [125I]T4 and unlabeled T4 revealed a Kd of 2.2 x 10(-7) mol/L. The binding capacity for T4 was approximately 7 mumol/L. Thus, in this case of IgA-secreting myeloma, the monoclonal IgA acts as an additional thyroid hormone-binding protein in serum that interferes in the T4 and T3 RIAs. This is the first report of a monoclonal IgA producing an apparent euthyroid hyperthyroxinemia.
Collapse
|
47
|
Factitious hyperthyroxinemia due to a monoclonal IgA in a case of multiple myeloma. Clin Chem 1993; 39:1739-42. [PMID: 8353966] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
A clinically euthyroid 53-year-old woman with an IgA-lambda-secreting multiple myeloma presented with increased serum concentrations of thyroid hormones. Laboratory studies revealed increased total thyroxine (T4) and triiodothyronine (T3) concentrations, a high-normal free T4 concentration, and a normal basal thyrotropin (TSH) concentration with a normal response to thyroliberin (TRH). Her serum concentration of IgA was 11,040 mg/L (normal range 900-4500 mg/L) and immunoelectrophoresis revealed it to be monoclonal. This monoclonal IgA bound both T4 and T3, as determined by serum immunoelectrophoresis and direct binding studies. Immunoelectrophoresis in the presence of [125I]T4 or [125I]T3 localized the radiolabeled iodothyronines to a band corresponding exactly to the precipitin arc of the monoclonal IgA. We performed direct binding studies with IgA purified by affinity chromatography with the lectin jacalin. Purified IgA (50 micrograms) bound both [125I]T4 (12.3%) and [125I]T3 (2.7%) specifically and in a dose-dependent manner. Scatchard analysis of competitive-binding data utilizing [125I]T4 and unlabeled T4 revealed a Kd of 2.2 x 10(-7) mol/L. The binding capacity for T4 was approximately 7 mumol/L. Thus, in this case of IgA-secreting myeloma, the monoclonal IgA acts as an additional thyroid hormone-binding protein in serum that interferes in the T4 and T3 RIAs. This is the first report of a monoclonal IgA producing an apparent euthyroid hyperthyroxinemia.
Collapse
|
48
|
Abstract
In summary, Sarcoidosis is a rare but well-recognized cause of diffuse osteosclerosis. The differential diagnosis of osteosclerosis is limited and includes osteoblastic metastases, sclerotic myeloma, myelofibrosis, and less common infiltrative bone marrow processes such as mastocytosis and sarcoidosis. In all of these entities the sclerosis is found most often in the axial (red marrow) skeleton. In this regard, it is interesting that cases of osseous sarcoid are usually lytic and located in the peripheral skeleton. In patients with osteosclerotic sarcoidosis, the diagnosis may be suggested by a past history of the disease or ancillary signs such as hilar node enlargement and subtle skin involvement. However, the specific diagnosis usually requires bone marrow biopsy with the demonstration of extensive, noncaseating granulomas.
Collapse
|
49
|
Abstract
Abstract
We describe a two-site time-resolved immunofluorometric assay for guinea pig vascular permeability factor (VPF) for quantifying VPF in different biological fluids. Antibody against the carboxy terminus (C-IgG) is immobilized on microtiter wells, and antibody against the amino terminus (N-IgG) is labeled with Eu(3+)-chelate. Line 10 tumor culture medium, known to be rich in VPF, is assayed in a two-step incubation. Bound Eu3+ is then quantified by dissociation into a fluorescent enhancement solution, with measurement of the time-resolved fluorescence. The analytical sensitivity is 0.35 VPF unit, and the intra-assay CV is about 20%. The assay is specific for VPF, because pre-treatment with the appropriate C- or N-peptide, or pre-extraction of VPF, greatly decreases fluorescence. The VPF immunoassay is highly correlated (r2 = 0.94) with the Miles permeability assay, the classical bioassay of VPF. In addition, the immunofluorometric assay is about 30-fold more sensitive than the Miles assay.
Collapse
|
50
|
Development of time-resolved immunofluorometric assay of vascular permeability factor. Clin Chem 1992; 38:71-5. [PMID: 1733610] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
We describe a two-site time-resolved immunofluorometric assay for guinea pig vascular permeability factor (VPF) for quantifying VPF in different biological fluids. Antibody against the carboxy terminus (C-IgG) is immobilized on microtiter wells, and antibody against the amino terminus (N-IgG) is labeled with Eu(3+)-chelate. Line 10 tumor culture medium, known to be rich in VPF, is assayed in a two-step incubation. Bound Eu3+ is then quantified by dissociation into a fluorescent enhancement solution, with measurement of the time-resolved fluorescence. The analytical sensitivity is 0.35 VPF unit, and the intra-assay CV is about 20%. The assay is specific for VPF, because pre-treatment with the appropriate C- or N-peptide, or pre-extraction of VPF, greatly decreases fluorescence. The VPF immunoassay is highly correlated (r2 = 0.94) with the Miles permeability assay, the classical bioassay of VPF. In addition, the immunofluorometric assay is about 30-fold more sensitive than the Miles assay.
Collapse
|