1
|
AirPen: A Wearable Monitor for Characterizing Exposures to Particulate Matter and Volatile Organic Compounds. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2023. [PMID: 37450410 PMCID: PMC10373498 DOI: 10.1021/acs.est.3c02238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/18/2023]
Abstract
Exposure to air pollution is a leading risk factor for disease and premature death, but technologies for assessing personal exposure to particulate and gaseous air pollutants, including the timing and location of such exposures, are limited. We developed a small, quiet, wearable monitor, called the AirPen, to quantify personal exposures to fine particulate matter (PM2.5) and volatile organic compounds (VOCs). The AirPen combines physical sample collection (PM onto a filter and VOCs onto a sorbent tube) with a suite of low-cost sensors (for PM, VOCs, temperature, pressure, humidity, light intensity, location, and motion). We validated the AirPen against conventional personal sampling equipment in the laboratory and then conducted a field study to measure at-work and away-from-work exposures to PM2.5 and VOCs among employees at an agricultural facility in Colorado, USA. The resultant sampling and sensor data indicated that personal exposures to benzene, toluene, ethylbenzene, and xylenes were dominated by a specific workplace location. These results illustrate how the AirPen can be used to advance our understanding of personal exposure to air pollution as a function of time, location, source, and activity, even in the absence of detailed activity diary data.
Collapse
|
2
|
Acute differences in blood lipids and inflammatory biomarkers following controlled exposures to cookstove air pollution in the STOVES study. INTERNATIONAL JOURNAL OF ENVIRONMENTAL HEALTH RESEARCH 2022; 32:565-578. [PMID: 32615777 PMCID: PMC7775880 DOI: 10.1080/09603123.2020.1785402] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2020] [Revised: 06/15/2020] [Accepted: 06/17/2020] [Indexed: 05/24/2023]
Abstract
Household air pollution is a leading risk factor for morbidity and premature mortality. Numerous cookstoves have been developed to reduce household air pollution, but it is unclear whether such cookstoves meaningfully improve health. In a controlled exposure study with a crossover design, we assessed the effect of pollution emitted from multiple cookstoves on acute differences in blood lipids and inflammatory biomarkers. Participants (n = 48) were assigned to treatment sequences of exposure to air pollution emitted from five cookstoves and a filtered-air control. Blood lipids and inflammatory biomarkers were measured before and 0, 3, and 24 hours after treatments. Many of the measured outcomes had inconsistent results. However, compared to control, intercellular adhesion molecule-1 was higher 3 hours after all treatments, and C-reactive protein and serum amyloid-A were higher 24 hours after the highest treatment. Our results suggest that short-term exposure to cookstove air pollution can increase inflammatory biomarkers within 24 hours.
Collapse
|
3
|
Short-term differences in cardiac function following controlled exposure to cookstove air pollution: The subclinical tests on volunteers exposed to smoke (STOVES) study. ENVIRONMENT INTERNATIONAL 2021; 146:106254. [PMID: 33221594 PMCID: PMC7775898 DOI: 10.1016/j.envint.2020.106254] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/18/2020] [Revised: 10/09/2020] [Accepted: 10/27/2020] [Indexed: 05/24/2023]
Abstract
BACKGROUND Exposure to household air pollution from solid fuel combustion for cooking and heating is an important risk factor for premature death and disability worldwide. Current evidence supports an association of ambient air pollution with cardiovascular disease but is limited for household air pollution and for cardiac function. Controlled exposure studies can complement evidence provided by field studies. OBJECTIVES To investigate effects of short-term, controlled exposures to emissions from five cookstoves on measures of cardiac function. METHODS Forty-eight healthy adults (46% female; 20-36 years) participated in six, 2-h exposures ('treatments'), including emissions from five cookstoves and a filtered-air control. Target fine particulate matter (PM2.5) exposure-concentrations per treatment were: control, 0 µg/m3; liquefied petroleum gas, 10 µg/m3; gasifier, 35 µg/m3; fan rocket, 100 µg/m3; rocket elbow, 250 µg/m3; and three stone fire, 500 µg/m3. Participants were treated in a set (pre-randomized) sequence as groups of 4 to minimize order bias and time-varying confounders. Heart rate variability (HRV) and cardiac repolarization metrics were calculated as 5-min means immediately and at 3 h following treatment, for analysis in linear mixed-effects models comparing cookstove to control. RESULTS Short-term differences in SDNN (standard deviation of duration of all NN intervals) and VLF (very-low frequency power) existed for several cookstoves compared to control. While all cookstoves compared to control followed a similar trend for SDNN, the greatest effect was seen immediately following three stone fire (β = -0.13 ms {%}; 95% confidence interval = -0.22, -0.03%), which reversed in direction at 3 h (0.03%; -0.06, 0.13%). VLF results were similar in direction and timing to SDNN; however, other HRV or cardiac repolarization results were not similar to those for SDNN. DISCUSSION We observed some evidence of short-term, effects on HRV immediately following cookstove treatments compared to control. Our results suggest that cookstoves with lower PM2.5 emissions are potentially capable of affecting cardiac function, similar to stoves emitting higher PM2.5 emissions.
Collapse
|
4
|
Design and performance of UPAS inlets for respirable and thoracic mass sampling. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2020; 17:274-282. [PMID: 32282284 DOI: 10.1080/15459624.2020.1741595] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
The Ultrasonic Personal Aerosol Sampler (UPAS) is a small, lightweight, and quiet sampler that collects airborne particulate matter on a filter for gravimetric or compositional analysis. The objective of this work was to develop UPAS inlets with collection efficiencies that match criteria for respirable or thoracic mass sampling. The two-stage inlet for respirable mass described here utilizes an impaction stage and a cyclone, whereas the one-stage inlet for thoracic mass sampling utilizes a circular slot impactor. Inlet designs are based on particle collection theory used in conjunction with an optimization algorithm to predict initial inlet dimensions; these predictions were the starting points for experiments that finalized dimensions and operating conditions. Both the respirable mass inlet and the thoracic mass inlet described here are interchangeable with the UPAS, and both have efficiencies that match well with their respective standards. With either inlet, the collected sample should be within ±5% of what the standard specifies for aerosols with reasonably broad size distributions.
Collapse
|
5
|
Acute changes in lung function following controlled exposure to cookstove air pollution in the subclinical tests of volunteers exposed to smoke (STOVES) study. Inhal Toxicol 2020; 32:115-123. [PMID: 32297528 DOI: 10.1080/08958378.2020.1751750] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
Background: Exposure to household air pollution generated as a result of cooking and heating is a leading contributor to global disease. The effects of cookstove-generated air pollution on adult lung function, however, remain uncertain.Objectives: We investigated acute responses in lung function following controlled exposures to cookstove-generated air pollution.Methods: We recruited 48 healthy adult volunteers to undergo six two-hour treatments: a filtered-air control and emissions from five different stoves with fine particulate matter (PM2.5) targets from 10 to 500 µg/m3. Spirometry was conducted prior to exposure and immediately, and three and 24 h post-exposure. Mixed-effect models were used to estimate differences in post-exposure lung function for stove treatments versus control.Results: Immediately post-exposure, lung function was lower compared to the control for the three highest PM2.5-level stoves. The largest differences were for the fan rocket stove (target 250 µg/m3; forced vital capacity (FVC): -60 mL, 95% confidence interval (95% CI) -135, 15; forced expiratory volume (FEV1): -51 mL, 95% CI -117, 16; mid-expiratory flow (FEF25-75): -116 mL/s, 95% CI -239, 8). At 3 h post-exposure, lung function was lower compared to the control for all stove treatments; effects were of similar magnitude for all stoves. At 24 h post-exposure, results were consistent with a null association for FVC and FEV1; FEF25-75 was lower relative to the control for the gasifier, fan rocket, and three stone fire.Conclusions: Patterns suggesting short-term decreases in lung function follow from exposure to cookstove air pollution even for stove exposures with low PM2.5 levels.
Collapse
|
6
|
Acute differences in pulse wave velocity, augmentation index, and central pulse pressure following controlled exposures to cookstove air pollution in the Subclinical Tests of Volunteers Exposed to Smoke (SToVES) study. ENVIRONMENTAL RESEARCH 2020; 180:108831. [PMID: 31648072 PMCID: PMC6899199 DOI: 10.1016/j.envres.2019.108831] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/24/2019] [Revised: 10/15/2019] [Accepted: 10/16/2019] [Indexed: 05/24/2023]
Abstract
Household air pollution emitted from solid-fuel cookstoves used for domestic cooking is a leading risk factor for morbidity and premature mortality globally. There have been attempts to design and distribute lower emission cookstoves, yet it is unclear if they meaningfully improve health. Using a crossover design, we assessed differences in central aortic hemodynamics and arterial stiffness following controlled exposures to air pollution emitted from five different cookstove technologies compared to a filtered air control. Forty-eight young, healthy participants were assigned to six 2-h controlled treatments of pollution from five different cookstoves and a filtered air control. Each treatment had a target concentration for fine particulate matter: filtered air control = 0 μg/m3, liquefied petroleum gas = 10 μg/m3, gasifier = 35 μg/m3, fan rocket = 100 μg/m3, rocket elbow = 250 μg/m3, three stone fire = 500 μg/m3. Pulse wave velocity (PWV), central augmentation index (AIx), and central pulse pressure (CPP) were measured before and at three time points after each treatment (0, 3, and 24 h). Linear mixed models were used to assess differences in the outcomes for each cookstove treatment compared to control. PWV and CPP were marginally higher 24 h after all cookstove treatments compared to control. For example, PWV was 0.15 m/s higher (95% confidence interval: -0.02, 0.31) and CPP was 0.6 mmHg higher (95% confidence interval: -0.8, 2.1) 24 h after the three stone fire treatment compared to control. The magnitude of the differences compared to control was similar across all cookstove treatments. PWV and CPP had no consistent trends at the other post-treatment time points (0 and 3 h). No consistent trends were observed for AIx at any post-treatment time point. Our findings suggest higher levels of PWV and CPP within 24 h after 2-h controlled treatments of pollution from five different cookstove technologies. The similar magnitude of the differences following each cookstove treatment compared to control may indicate that acute exposures from even the cleanest cookstove technologies can adversely impact these subclinical markers of cardiovascular health, although differences were small and may not be clinically meaningful.
Collapse
|
7
|
Abstract
Background Exposure to air pollution from solid fuel used in residential cookstoves is considered a leading environmental risk factor for disease globally, but evidence for this relationship is largely extrapolated from literature on smoking, secondhand smoke, and ambient fine particulate matter (PM2.5). Methods and Results We conducted a controlled human‐exposure study (STOVES [the Subclinical Tests on Volunteers Exposed to Smoke] Study) to investigate acute responses in blood pressure following exposure to air pollution emissions from cookstove technologies. Forty‐eight healthy adults received 2‐hour exposures to 5 cookstove treatments (three stone fire, rocket elbow, fan rocket elbow, gasifier, and liquefied petroleum gas), spanning PM2.5 concentrations from 10 to 500 μg/m3, and a filtered air control (0 μg/m3). Thirty minutes after exposure, systolic pressure was lower for the three stone fire treatment (500 μg/m3PM2.5) compared with the control (−2.3 mm Hg; 95% CI, −4.5 to −0.1) and suggestively lower for the gasifier (35 μg/m3PM2.5; −1.8 mm Hg; 95% CI, −4.0 to 0.4). No differences were observed at 3 hours after exposure; however, at 24 hours after exposure, mean systolic pressure was 2 to 3 mm Hg higher for all treatments compared with control except for the rocket elbow stove. No differences were observed in diastolic pressure for any time point or treatment. Conclusions Short‐term exposure to air pollution from cookstoves can elicit an increase in systolic pressure within 24 hours. This response occurred across a range of stove types and PM2.5 concentrations, raising concern that even low‐level exposures to cookstove air pollution may pose adverse cardiovascular effects.
Collapse
|
8
|
A Laboratory Assessment of 120 Air Pollutant Emissions from Biomass and Fossil Fuel Cookstoves. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2019; 53:7114-7125. [PMID: 31132247 DOI: 10.1021/acs.est.8b07019] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Cookstoves emit many pollutants that are harmful to human health and the environment. However, most of the existing scientific literature focuses on fine particulate matter (PM2.5) and carbon monoxide (CO). We present an extensive data set of speciated air pollution emissions from wood, charcoal, kerosene, and liquefied petroleum gas (LPG) cookstoves. One-hundred and twenty gas- and particle-phase constituents-including organic carbon, elemental carbon (EC), ultrafine particles (10-100 nm), inorganic ions, carbohydrates, and volatile/semivolatile organic compounds (e.g., alkanes, alkenes, alkynes, aromatics, carbonyls, and polycyclic aromatic hydrocarbons (PAHs))-were measured in the exhaust from 26 stove/fuel combinations. We find that improved biomass stoves tend to reduce PM2.5 emissions; however, certain design features (e.g., insulation or a fan) tend to increase relative levels of other coemitted pollutants (e.g., EC ultrafine particles, carbonyls, or PAHs, depending on stove type). In contrast, the pressurized kerosene and LPG stoves reduced all pollutants relative to a traditional three-stone fire (≥93% and ≥79%, respectively). Finally, we find that PM2.5 and CO are not strong predictors of coemitted pollutants, which is problematic because these pollutants may not be indicators of other cookstove smoke constituents (such as formaldehyde and acetaldehyde) that may be emitted at concentrations that are harmful to human health.
Collapse
|
9
|
Personal Exposure to PM 2.5 Black Carbon and Aerosol Oxidative Potential using an Automated Microenvironmental Aerosol Sampler (AMAS). ENVIRONMENTAL SCIENCE & TECHNOLOGY 2018; 52:11267-11275. [PMID: 30200753 PMCID: PMC6203932 DOI: 10.1021/acs.est.8b02992] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Traditional methods for measuring personal exposure to fine particulate matter (PM2.5) are cumbersome and lack spatiotemporal resolution; methods that are time-resolved are limited to a single species/component of PM. To address these limitations, we developed an automated microenvironmental aerosol sampler (AMAS), capable of resolving personal exposure by microenvironment. The AMAS is a wearable device that uses a GPS sensor algorithm in conjunction with a custom valve manifold to sample PM2.5 onto distinct filter channels to evaluate home, school, and other (e.g., outdoors, in transit, etc.) exposures. Pilot testing was conducted in Fresno, CA where 25 high-school participants ( n = 37 sampling events) wore an AMAS for 48-h periods in November 2016. Data from 20 (54%) of the 48-h samples collected by participants were deemed valid and the filters were analyzed for PM2.5 black carbon (BC) using light transmissometry and aerosol oxidative potential (OP) using the dithiothreitol (DTT) assay. The amount of inhaled PM2.5 was calculated for each microenvironment to evaluate the health risks associated with exposure. On average, the estimated amount of inhaled PM2.5 BC (μg day-1) and OP [(μM min-1) day-1] was greatest at home, owing to the proportion of time spent within that microenvironment. Validation of the AMAS demonstrated good relative precision (8.7% among collocated instruments) and a mean absolute error of 22% for BC and 33% for OP when compared to a traditional personal sampling instrument. This work demonstrates the feasibility of new technology designed to quantify personal exposure to PM2.5 species within distinct microenvironments.
Collapse
|
10
|
Personal exposure of dairy workers to dust, endotoxin, muramic acid, ergosterol, and ammonia on large-scale dairies in the high plains Western United States. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2018; 15:182-193. [PMID: 29157144 PMCID: PMC8641559 DOI: 10.1080/15459624.2017.1403610] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
Dairy workers experience a high degree of bioaerosol exposure, composed of an array of biological and chemical constituents, which have been tied to adverse health effects. A better understanding of the variation in the magnitude and composition of exposures by task is needed to inform worker protection strategies. To characterize the levels and types of exposures, 115 dairy workers grouped into three task categories on nine farms in the high plains Western United States underwent personal monitoring for inhalable dust, endotoxin, 3-hydroxy fatty acids (3-OHFA), muramic acid, ergosterol, and ammonia through one work shift. Eighty-nine percent of dairy workers were exposed to endotoxin at concentrations exceeding the recommended exposure guidelines (adjusted for a long work shift). The proportion of workers with exposures exceeding recommended guidelines was lower for inhalable dust (12%), and ammonia (1%). Ergosterol exposures were only measurable on 28% of samples, primarily among medical workers and feed handlers. Milking parlor workers were exposed to significantly higher inhalable dust, endotoxin, 3-OHFA, ammonia, and muramic acid concentrations compared to workers performing other tasks. Development of large modern dairies has successfully made progress in reducing worker exposures and lung disease prevalence. However, exposure to endotoxin, dust, and ammonia continues to present a significant risk to worker health on North American dairies, especially for workers in milking parlors. This study was among the first to concurrently evaluate occupational exposure to assayable endotoxin (lipid A), 3-hydroxy fatty acids or 3-OHFA (a chemical measure of cell bound and noncell-bound endotoxins), muramic acid, ergosterol, and ammonia among workers on Western U.S. dairies. There remains a need for cost-effective, culturally acceptable intervention strategies integrated in OHS Risk Management and production systems to further optimize worker health and farm productivity.
Collapse
|
11
|
Performance of prototype high-flow inhalable dust sampler in a livestock production facility. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2017; 14:313-322. [PMID: 27792469 PMCID: PMC5503137 DOI: 10.1080/15459624.2016.1240872] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
A high-flow inhalable sampler, designed for operational flow rates up to 10 L/min using computer simulations and examined in wind tunnel experiments, was evaluated in the field. This prototype sampler was deployed in collocation with an IOM (the benchmark standard sampler) in a swine farrowing building to examine the sampling performance for assessing concentrations of inhalable particulate mass and endotoxin. Paired samplers were deployed for 24 hr on 19 days over a 3-month period. On each sampling day, the paired samplers were deployed at three fixed locations and data were analyzed to identify agreement and to examine systematic biases between concentrations measured by these samplers. Thirty-six paired gravimetric samples were analyzed; insignificant, unsubstantial differences between concentrations were identified between the two samplers (p = 0.16; mean difference 0.03 mg/m3). Forty-four paired samples were available for endotoxin analysis, and a significant (p = 0.001) difference in endotoxin concentration was identified: the prototype sampler, on average, had 120 EU/m3 more endotoxin than did the IOM samples. Since the same gravimetric samples were analyzed for endotoxin content, the endotoxin difference is likely attributable to differences in endotoxin extraction. The prototype's disposable thin-film polycarbonate capsule was included with the filter in the 1-hr extraction procedure while the internal plastic cassette of the IOM required a rinse procedure that is susceptible to dust losses. Endotoxin concentrations measured with standard plastic IOM inserts that follow this rinsing procedure may underestimate the true endotoxin exposure concentrations. The maximum concentrations in the study (1.55 mg/m3 gravimetric, 2328 EU/m3 endotoxin) were lower than other agricultural or industrial environments. Future work should explore the performance of the prototype sampler in dustier environments, where concentrations approach particulates not otherwise specified (PNOS) limits of 10 mg/m3, including using the prototype as a personal sampler.
Collapse
|
12
|
Development and evaluation of an ultrasonic personal aerosol sampler. INDOOR AIR 2017; 27:409-416. [PMID: 27354176 PMCID: PMC5199626 DOI: 10.1111/ina.12318] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2016] [Accepted: 06/21/2016] [Indexed: 05/05/2023]
Abstract
Assessing personal exposure to air pollution has long proven challenging due to technological limitations posed by the samplers themselves. Historically, wearable aerosol monitors have proven to be expensive, noisy, and burdensome. The objective of this work was to develop a new type of wearable monitor, an ultrasonic personal aerosol sampler (UPAS), to overcome many of the technological limitations in personal exposure assessment. The UPAS is a time-integrated monitor that features a novel micropump that is virtually silent during operation. A suite of onboard environmental sensors integrated with this pump measure and record mass airflow (0.5-3.0 L/min, accurate within 5%), temperature, pressure, relative humidity, light intensity, and acceleration. Rapid development of the UPAS was made possible through recent advances in low-cost electronics, open-source programming platforms, and additive manufacturing for rapid prototyping. Interchangeable cyclone inlets provided a close match to the EPA PM2.5 mass criterion (within 5%) for device flows at either 1.0 or 2.0 L/min. Battery life varied from 23 to 45 hours depending on sample flow rate and selected filter media. Laboratory tests of the UPAS prototype demonstrate excellent agreement with equivalent federal reference method samplers for gravimetric analysis of PM2.5 across a broad range of concentrations.
Collapse
|
13
|
AgNP/Bi/Nafion-modified Disposable Electrodes for Sensitive Zn(II), Cd(II), and Pb(II) Detection in Aerosol Samples. ELECTROANAL 2016. [DOI: 10.1002/elan.201600591] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
14
|
Characterization of endotoxin collected on California dairies using personal and area-based sampling methods. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2012; 9:580-591. [PMID: 22946649 DOI: 10.1080/15459624.2012.713301] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Endotoxin, found in the cell wall of gram negative bacteria, is an important contributor to the biological activity of agriculture particulate matter (PM). We analyzed endotoxin in PM collected on 13 California dairies and from the breathing zone of 226 workers during the summer months of 2008. Two particle size fractions were measured: PM(2.5) and inhalable PM. Recombinant factor C assays were used to analyze biologically active endotoxin, while gas chromatography coupled with mass spectrometry in tandem was used to quantify total lipopolysaccharide. Biologically active endotoxin concentrations in the inhalable PM size fraction from area-based samples ranged from 11-2095 EU/m(3) and from 45-2061 EU/m(3) for personal samples. Total endotoxin in the inhalable PM size fraction ranged from 75-10,166 pmol/m(3) for area-based samples and 34-11,689 pmol/m(3) for personal samples. Area-based geometric mean concentrations for biologically active endotoxin and total endotoxin in PM(2.5) and inhalable PM size fractions were 3 EU/m(3), 149 EU/m(3), 60 pmol/m(3), and 515 pmol/m(3), respectively. Personal geometric mean concentrations in the inhalable PM size fraction were 334 EU/m(3), and 1178 pmol/m(3). Biologically active and total endotoxin concentration variation was best explained by meteorological data, wind speed, relative humidity, and dairy waste management practices. Differences in endotoxin concentration and composition were found across locations on the dairy.
Collapse
|
15
|
Evaluation of parlor cleaning as an intervention for decreased occupational exposure to dust and endotoxin among dairy parlor workers--a pilot study. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2012; 9:D136-D140. [PMID: 22702233 DOI: 10.1080/15459624.2012.691410] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
|
16
|
Endotoxin exposure and inflammation markers among agricultural workers in Colorado and Nebraska. JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH. PART A 2010; 73:5-22. [PMID: 19953416 DOI: 10.1080/15287390903248604] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
The adverse respiratory effects of agricultural dust inhalation are mediated in part by endotoxin, a constituent of gram-negative bacterial cell walls. This study quantified personal work-shift exposures to inhalable dust, endotoxin, and its reactive 3-hydroxy fatty acid (3-OHFA) constituents among workers in grain elevators, cattle feedlots, dairies, and on corn farms. Exposures were compared with post-work-shift nasal lavage fluid inflammation markers and respiratory symptoms. Breathing-zone personal air monitoring was performed over one work shift to quantify inhalable dust (Institute of Medicine samplers), endotoxin (recombinant factor C [rFC] assay), and 3-OHFA (gas chromatography/mass spectrometry). Post-shift nasal lavage fluids were assayed for polymorphonuclear neutrophils (PMN), myeloperoxidase (MPO), interleukin 8 (IL-8), albumin, and eosinophilic cation protein (ECP) concentrations. The geometric mean (GSD) of endotoxin exposure (rFC assay) among the 125 male participants was 888 +/- (6.5) EU/m(3), and 93% exceeded the proposed exposure limit (50 EU/m(3)). Mean PMN, MPO, albumin, and ECP levels were two- to threefold higher among workers in the upper quartile of 3-OHFA exposure compared to the lowest exposure quartile. Even numbered 3-OHFA were most strongly associated with nasal inflammation. Symptom prevalence was not elevated among exposed workers, possibly due to endotoxin tolerance or a healthy worker effect in this population. This is the first study to evaluate the relationship between endotoxin's 3-OHFA constituents in agricultural dust and nasal airway inflammation. More research is needed to characterize the extent to which these agents contribute to respiratory disease among agricultural workers.
Collapse
|
17
|
Muramic acid, endotoxin, 3-hydroxy fatty acids, and ergosterol content explain monocyte and epithelial cell inflammatory responses to agricultural dusts. JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH. PART A 2010; 73:684-700. [PMID: 20391112 PMCID: PMC2856089 DOI: 10.1080/15287390903578539] [Citation(s) in RCA: 80] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
In agricultural and other environments, inhalation of airborne microorganisms is linked to respiratory disease development. Bacterial endotoxins, peptidoglycans, and fungi are potential causative agents, but relative microbial characterization and inflammatory comparisons amongst agricultural dusts are not well described. The aim of this study was to determine the distribution of microbial endotoxin, 3-hydroxy fatty acids (3-OHFA), muramic acid, and ergosterol and evaluate inflammatory responses in human monocytes and bronchial epithelial cells with various dust samples. Settled surface dust was obtained from five environments: swine facility, dairy barn, grain elevator, domestic home (no pets), and domestic home with dog. Endotoxin concentration was determined by recombinant factor C (rFC). 3-OHFA, muramic acid, and ergosterol were measured using gas chromatography-mass spectrometry. Dust-induced inflammatory cytokine secretion in human monocytes and bronchial epithelial cells was evaluated. Endotoxin-independent dust-induced inflammatory responses were evaluated. Endotoxin and 3-OHFA levels were highest in agricultural dusts. Muramic acid, endotoxin, 3-OHFA, and ergosterol were detected in dusts samples. Muramic acid was highest in animal farming dusts. Ergosterol was most significant in grain elevator dust. Agricultural dusts induced monocyte tumor necrosis factor (TNF) alpha, interleukin (IL)-6, IL-8, and epithelial cell IL-6 and IL-8 secretion. Monocyte and epithelial IL-6 and IL-8 secretion was not dependent on endotoxin. House dust(s) induced monocyte TNFalpha, IL-6, and IL-8 secretion. Swine facility dust generally produced elevated responses compared to other dusts. Agricultural dusts are complex with significant microbial component contribution. Large animal farming dust(s)-induced inflammation is not entirely dependent on endotoxin. Addition of muramic acid to endotoxin in large animal farming environment monitoring is warranted.
Collapse
|
18
|
Field and wind tunnel comparison of four aerosol samplers using agricultural dusts. ACTA ACUST UNITED AC 2009; 53:585-94. [PMID: 19443852 DOI: 10.1093/annhyg/mep021] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Occupational lung disease is a significant problem among agricultural workers exposed to organic dusts. Measurements of exposure in agricultural environments in the USA have traditionally been conducted using 37-mm closed-face cassettes (CFCs) and respirable Cyclones. Inhalable aerosol samplers offer significant improvement for dose estimation studies to reduce respiratory disease. The goals of this study were to determine correction factors between the inhalable samplers (IOM and Button) and the CFC and Cyclone for dusts sampled in livestock buildings and to determine whether these factors vary among livestock types. Determination of these correction factors will allow comparison between inhalable measurements and historical measurements. Ten sets of samples were collected in swine, chicken, turkey, and dairy facilities in both Colorado and Iowa. Pairs of each sampling device were attached to the front and back of a rotating mannequin. Laboratory studies using a still-air chamber and a wind tunnel provided information regarding the effect of wind speed on sampler performance. Overall, the IOM had the lowest coefficient of variation (best precision) and was least affected by changes in wind speed. The performance of the Button was negatively impacted in poultry environments where larger (feather) particulates clogged the holes in the initial screen. The CFC/IOM ratios are important for comparisons between newer and older studies. Wind speed and dust type were both important factors affecting ratios. Based on the field studies (Table 6), a ratio of 0.56 is suggested as a conversion factor for the CFC/IOM (average for all environments because of no statistical difference). Suggested conversion factors for the Button/IOM are swine (0.57), chicken (0.80), turkey (0.53), and dairy (0.67). Any attempt to apply a conversion factor between the Cyclone and inhalable samplers is not recommended.
Collapse
|
19
|
Comparison of Endotoxin and Particle Bounce in Marple Cascade Samplers With and Without Impaction Grease. J Agromedicine 2009; 14:242-9. [DOI: 10.1080/10599240902845062] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
20
|
Characterization of a hooded human exposure apparatus for inhalation of gases and aerosols. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2004; 1:161-166. [PMID: 15204873 DOI: 10.1080/15459620490424447] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
A human exposure apparatus was designed to administer a gas and/or aerosol directly to the subject's face. This apparatus utilized a hood associated with a powered air-purifying respirator. The design criteria included the need to maximize subject comfort, maintain consistent atmospheres of a gas or dust within the hood, and the accurate use of direct-reading instruments to monitor exposure levels. An 83-L drum was used to pre-mix the gas or aerosol with the main dilution air prior to entering the hood worn by the subject. A clear plastic oxygen tent, ventilated with room exhaust air, was used to contain contaminants exiting the hood. Bypass valves were added to allow for a startup period during which contaminant concentration levels were allowed to stabilize prior to exposing the human subject. Results from characterization studies demonstrated that the system adequately contained contaminants within the oxygen tent, provided adequate mixing of contaminant and dilution air, produced stable contaminant concentrations over time, and was responsive to sudden changes in contaminant generation rate.
Collapse
|