Brain elastography in aging relates to fluid/solid trendlines. Phys Med Biol 2024. [PMID: 38670141 DOI: 10.1088/1361-6560/ad4446] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/28/2024]
Abstract
The relatively new tools of brain elastography have established a general trendline for healthy, aging adult humans, whereby the brain's viscoelastic properties "soften" over many decades. Earlier studies of the aging brain have demonstrated a wide spectrum of changes in morphology and composition towards the later decades of lifespan. This leads to a major question of causal mechanisms: of the many changes documented in structure and composition of the aging brain, which ones drive the long term trendline for viscoelastic properties of grey matter and white matter? The issue is important for illuminating which factors brain elastography is sensitive to, defining its unique role for study of the brain and clinical diagnoses of neurological disease and injury. We address these issues by examining trendlines in aging from our elastography data, also utilizing data from an earlier landmark study of brain composition, and from a biophysics model that captures the multiscale biphasic (fluid/solid) structure of the brain. Taken together, these imply that long term changes in extracellular water in the glymphatic system of the brain along with a decline in the extracellular matrix have a profound effect on the measured viscoelastic properties. Specifically, the trendlines indicate that water tends to replace solid fraction as a function of age, then grey matter stiffness decreases inversely as water fraction squared, whereas white matter stiffness declines inversely as water fraction to the 2/3 power, a behavior consistent with the cylindrical shape of the axons. These unique behaviors point to elastography of the brain as an important macroscopic measure of underlying microscopic structural change, with direct implications for clinical studies of aging, disease, and injury.
Collapse
|
2
|
WATUNet: a deep neural network for segmentation of volumetric sweep imaging ultrasound. MACHINE LEARNING: SCIENCE AND TECHNOLOGY 2024; 5:015042. [PMID: 38464559 PMCID: PMC10921088 DOI: 10.1088/2632-2153/ad2e15] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Revised: 01/31/2024] [Accepted: 02/28/2024] [Indexed: 03/12/2024] Open
Abstract
Limited access to breast cancer diagnosis globally leads to delayed treatment. Ultrasound, an effective yet underutilized method, requires specialized training for sonographers, which hinders its widespread use. Volume sweep imaging (VSI) is an innovative approach that enables untrained operators to capture high-quality ultrasound images. Combined with deep learning, like convolutional neural networks, it can potentially transform breast cancer diagnosis, enhancing accuracy, saving time and costs, and improving patient outcomes. The widely used UNet architecture, known for medical image segmentation, has limitations, such as vanishing gradients and a lack of multi-scale feature extraction and selective region attention. In this study, we present a novel segmentation model known as Wavelet_Attention_UNet (WATUNet). In this model, we incorporate wavelet gates and attention gates between the encoder and decoder instead of a simple connection to overcome the limitations mentioned, thereby improving model performance. Two datasets are utilized for the analysis: the public 'Breast Ultrasound Images' dataset of 780 images and a private VSI dataset of 3818 images, captured at the University of Rochester by the authors. Both datasets contained segmented lesions categorized into three types: no mass, benign mass, and malignant mass. Our segmentation results show superior performance compared to other deep networks. The proposed algorithm attained a Dice coefficient of 0.94 and an F1 score of 0.94 on the VSI dataset and scored 0.93 and 0.94 on the public dataset, respectively. Moreover, our model significantly outperformed other models in McNemar's test with false discovery rate correction on a 381-image VSI set. The experimental findings demonstrate that the proposed WATUNet model achieves precise segmentation of breast lesions in both standard-of-care and VSI images, surpassing state-of-the-art models. Hence, the model holds considerable promise for assisting in lesion identification, an essential step in the clinical diagnosis of breast lesions.
Collapse
|
3
|
Multiparametric ultrasound imaging for early-stage steatosis: Comparison with magnetic resonance imaging-based proton density fat fraction. Med Phys 2024; 51:1313-1325. [PMID: 37503961 DOI: 10.1002/mp.16648] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Revised: 06/23/2023] [Accepted: 07/04/2023] [Indexed: 07/29/2023] Open
Abstract
BACKGROUND The prevalence of liver diseases, especially steatosis, requires a more convenient and noninvasive tool for liver diagnosis, which can be a surrogate for the gold standard biopsy. Magnetic resonance (MR) measurement offers potential, however ultrasound (US) has better accessibility than MR. PURPOSE This study aims to suggest a multiparametric US approach which demonstrates better quantification and imaging performance than MR imaging-based proton density fat fraction (MRI-PDFF) for hepatic steatosis assessment. METHODS We investigated early-stage steatosis to evaluate our approach. An in vivo (within the living) animal study was performed. Fat inclusions were accumulated in the animal livers by feeding a methionine and choline deficient (MCD) diet for 2 weeks. The animals (n = 19) underwent US and MR imaging, and then their livers were excised for histological staining. From the US, MR, and histology images, fat accumulation levels were measured and compared: multiple US parameters; MRI-PDFF; histology fat percentages. Seven individual US parameters were extracted using B-mode measurement, Burr distribution estimation, attenuation estimation, H-scan analysis, and shear wave elastography. Feature selection was performed, and the selected US features were combined, providing quantification of fat accumulation. The combined parameter was used for visualizing the localized probability of fat accumulation level in the liver; This procedure is known as disease-specific imaging (DSI). RESULTS The combined US parameter can sensitively assess fat accumulation levels, which is highly correlated with histology fat percentage (R = 0.93, p-value < 0.05) and outperforms the correlation between MRI-PDFF and histology (R = 0.89, p-value < 0.05). Although the seven individual US parameters showed lower correlation with histology compared to MRI-PDFF, the multiparametric analysis enabled US to outperform MR. Furthermore, this approach allowed DSI to detect and display gradual increases in fat accumulation. From the imaging output, we measured the color-highlighted area representing fatty tissues, and the fat fraction obtained from DSI and histology showed strong agreement (R = 0.93, p-value < 0.05). CONCLUSIONS We demonstrated that fat quantification utilizing a combination of multiple US parameters achieved higher performance than MRI-PDFF; therefore, our multiparametric analysis successfully combined selected features for hepatic steatosis characterization. We anticipate clinical use of our proposed multiparametric US analysis, which could be beneficial in assessing steatosis in humans.
Collapse
|
4
|
H-Scan Discrimination for Tumor Microenvironmental Heterogeneity in Melanoma. ULTRASOUND IN MEDICINE & BIOLOGY 2024; 50:268-276. [PMID: 37993356 PMCID: PMC10794040 DOI: 10.1016/j.ultrasmedbio.2023.10.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Revised: 10/24/2023] [Accepted: 10/28/2023] [Indexed: 11/24/2023]
Abstract
OBJECTIVE Melanoma is a form of malignant skin cancer that exhibits significant inter-tumoral differences in the tumor microenvironment (TME) secondary to genetic mutations. The heterogeneity may be subtle but can complicate the treatment of metastatic melanoma, contributing to a high mortality rate. Therefore, developing an accurate and non-invasive procedure to discriminate microenvironmental heterogeneity to facilitate therapy selection is an important goal. METHODS In vivo murine melanoma models that recapitulate human disease using synchronous implanted YUMM 1.7 (Yale University Mouse Melanoma) and YUMMER 1.7 (Yale University Mouse Melanoma Exposed to Radiation) murine melanoma lines were investigated. Mice were treated with antibodies to modulate the immune response and longitudinally scanned with ultrasound (US). US radiofrequency data were processed using the H-scan analysis, attenuation estimation and B-mode processing to extract five US features. The measures were used to compare different TMEs (YUMMER vs. YUMM) and responses to immunomodulatory therapies with CD8 depletion or programmed cell death protein 1 (PD-1) inhibition. RESULTS Multiparametric analysis produced a combined H-scan parameter, resolving significant differences (i) between untreated YUMMER and YUMM and (ii) between untreated, PD-1-treated and CD8-treated YUMMER. However, more importantly, the B-mode and attenuation measures failed to differentiate YUMMER and YUMM and to monitor treatment responses, indicating that H-scan is required to differentiate subtle differences within the TME. CONCLUSION We anticipate that the H-scan analysis could discriminate heterogeneous melanoma metastases and guide diagnosis and treatment selection, potentially reducing the need for invasive biopsies or immunologic procedures.
Collapse
|
5
|
Corrigendum: Theory of sleep/wake cycles affecting brain elastography (2022 Phys. Med. Biol.67225013). Phys Med Biol 2023; 68:219501. [PMID: 37917188 DOI: 10.1088/1361-6560/ad051f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Accepted: 10/19/2023] [Indexed: 11/04/2023]
|
6
|
Limitations of Curl and Directional Filters in Elastography. ARXIV 2023:arXiv:2305.08734v1. [PMID: 37292466 PMCID: PMC10246078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
In the approaches to elastography, two mathematical operations have been frequently applied to improve the final estimate of shear wave speed and shear modulus of tissues. The vector curl operator can separate out the transverse component of a complicated displacement field, and directional filters can separate distinct orientations of wave propagation. However, there are practical limitations that can prevent the intended improvement in elastography estimates. Some simple configurations of wavefields relevant to elastography are examined against theoretical models within the semi-infinite elastic medium and guided waves in a bounded medium. The Miller-Pursey solutions in simplified form are examined for the semi-infinite medium and the Lamb wave symmetric form is considered for the guided wave structure. In both cases, wave combinations along with practical limits on the imaging plane can prevent the curl and directional filter operations from directly providing an improved measure of shear wave speed and shear modulus. Additional limits on signal-to-noise and the support of filters also restrict the applicability of these strategies for improving elastographic measures. Practical implementations of shear wave excitations applied to the body and to bounded structures within the body can involve waves that are not easily resolved by the vector curl operator and directional filters. These limits may be overcome by more advanced strategies or simple improvements in baseline parameters including the size of the region of interest and the number of shear waves propagated within.
Collapse
|
7
|
Fluid compartments influence elastography of the aging mouse brain. Phys Med Biol 2023; 68:095004. [PMID: 36996842 PMCID: PMC10108361 DOI: 10.1088/1361-6560/acc922] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Accepted: 03/30/2023] [Indexed: 04/01/2023]
Abstract
Objective. Elastography of the brain has the potential to reveal subtle but clinically important changes in the structure and composition as a function of age, disease, and injury.Approach. In order to quantify the specific effects of aging on mouse brain elastography, and to determine the key factors influencing observed changes, we applied optical coherence tomography reverberant shear wave elastography at 2000 Hz to a group of wild-type healthy mice ranging from young to old age.Main results. We found a strong trend towards increasing stiffness with age, with an approximately 30% increase in shear wave speed from 2 months to 30 months within this sampled group. Furthermore, this appears to be strongly correlated with decreasing measures of whole brain fluid content, so older brains have less water and are stiffer. Rheological models are applied, and the strong effect is captured by specific assignment of changes to the glymphatic compartment of the brain fluid structures along with a correlated change in the parenchymal stiffness.Significance. Short-term and longer-term changes in elastography measures may provide a sensitive biomarker of progressive and fine-scale changes in the glymphatic fluid channels and parenchymal components of the brain.
Collapse
|
8
|
Breast Ultrasound Volume Sweep Imaging: A New Horizon in Expanding Imaging Access for Breast Cancer Detection. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2023; 42:817-832. [PMID: 35802491 DOI: 10.1002/jum.16047] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Revised: 06/11/2022] [Accepted: 06/13/2022] [Indexed: 05/26/2023]
Abstract
OBJECTIVE The majority of people in the world lack basic access to breast diagnostic imaging resulting in delay to diagnosis of breast cancer. In this study, we tested a volume sweep imaging (VSI) ultrasound protocol for evaluation of palpable breast lumps that can be performed by operators after minimal training without prior ultrasound experience as a means to increase accessibility to breast ultrasound. METHODS Medical students without prior ultrasound experience were trained for less than 2 hours on the VSI breast ultrasound protocol. Patients presenting with palpable breast lumps for standard of care ultrasound examination were scanned by a trained medical student with the VSI protocol using a Butterfly iQ handheld ultrasound probe. Video clips of the VSI scan imaging were later interpreted by an attending breast imager. Results of VSI scan interpretation were compared to the same-day standard of care ultrasound examination. RESULTS Medical students scanned 170 palpable lumps with the VSI protocol. There was 97% sensitivity and 100% specificity for a breast mass on VSI corresponding to 97.6% agreement with standard of care (Cohen's κ = 0.95, P < .0001). There was a detection rate of 100% for all cancer presenting as a sonographic mass. High agreement for mass characteristics between VSI and standard of care was observed, including 87% agreement on Breast Imaging-Reporting and Data System assessments (Cohen's κ = 0.82, P < .0001). CONCLUSIONS Breast ultrasound VSI for palpable lumps offers a promising means to increase access to diagnostic imaging in underserved areas. This approach could decrease delay to diagnosis for breast cancer, potentially improving morbidity and mortality.
Collapse
|
9
|
Reverberant magnetic resonance elastographic imaging using a single mechanical driver. Phys Med Biol 2023; 68:055015. [PMID: 36780698 PMCID: PMC9969521 DOI: 10.1088/1361-6560/acbbb7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Accepted: 02/13/2023] [Indexed: 02/15/2023]
Abstract
Reverberant elastography provides fast and robust estimates of shear modulus; however, its reliance on multiple mechanical drivers hampers clinical utility. In this work, we hypothesize that for constrained organs such as the brain, reverberant elastography can produce accurate magnetic resonance elastograms with a single mechanical driver. To corroborate this hypothesis, we performed studies on healthy volunteers (n= 3); and a constrained calibrated brain phantom containing spherical inclusions with diameters ranging from 4-18 mm. In both studies (i.e. phantom and clinical), imaging was performed at frequencies of 50 and 70 Hz. We used the accuracy and contrast-to-noise ratio performance metrics to evaluate reverberant elastograms relative to those computed using the established subzone inversion method. Errors incurred in reverberant elastograms varied from 1.3% to 16.6% when imaging at 50 Hz and 3.1% and 16.8% when imaging at 70 Hz. In contrast, errors incurred in subzone elastograms ranged from 1.9% to 13% at 50 Hz and 3.6% to 14.9% at 70 Hz. The contrast-to-noise ratio of reverberant elastograms ranged from 63.1 to 73 dB compared to 65 to 66.2 dB for subzone elastograms. The average global brain shear modulus estimated from reverberant and subzone elastograms was 2.36 ± 0.07 kPa and 2.38 ± 0.11 kPa, respectively, when imaging at 50 Hz and 2.70 ± 0.20 kPa and 2.89 ± 0.60 kPa respectively, when imaging at 70 Hz. The results of this investigation demonstrate that reverberant elastography can produce accurate, high-quality elastograms of the brain with a single mechanical driver.
Collapse
|
10
|
Improving breast cancer diagnosis by incorporating raw ultrasound parameters into machine learning. MACHINE LEARNING: SCIENCE AND TECHNOLOGY 2022; 3:045013. [PMID: 36698865 PMCID: PMC9855672 DOI: 10.1088/2632-2153/ac9bcc] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2022] [Revised: 10/15/2022] [Accepted: 10/19/2022] [Indexed: 01/28/2023] Open
Abstract
The improved diagnostic accuracy of ultrasound breast examinations remains an important goal. In this study, we propose a biophysical feature-based machine learning method for breast cancer detection to improve the performance beyond a benchmark deep learning algorithm and to furthermore provide a color overlay visual map of the probability of malignancy within a lesion. This overall framework is termed disease-specific imaging. Previously, 150 breast lesions were segmented and classified utilizing a modified fully convolutional network and a modified GoogLeNet, respectively. In this study multiparametric analysis was performed within the contoured lesions. Features were extracted from ultrasound radiofrequency, envelope, and log-compressed data based on biophysical and morphological models. The support vector machine with a Gaussian kernel constructed a nonlinear hyperplane, and we calculated the distance between the hyperplane and each feature's data point in multiparametric space. The distance can quantitatively assess a lesion and suggest the probability of malignancy that is color-coded and overlaid onto B-mode images. Training and evaluation were performed on in vivo patient data. The overall accuracy for the most common types and sizes of breast lesions in our study exceeded 98.0% for classification and 0.98 for an area under the receiver operating characteristic curve, which is more precise than the performance of radiologists and a deep learning system. Further, the correlation between the probability and Breast Imaging Reporting and Data System enables a quantitative guideline to predict breast cancer. Therefore, we anticipate that the proposed framework can help radiologists achieve more accurate and convenient breast cancer classification and detection.
Collapse
|
11
|
Theory of sleep/wake cycles affecting brain elastography. Phys Med Biol 2022; 67:10.1088/1361-6560/ac9e40. [PMID: 36317278 PMCID: PMC9999375 DOI: 10.1088/1361-6560/ac9e40] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Accepted: 10/27/2022] [Indexed: 11/05/2022]
Abstract
As elastography of the brain finds increasing clinical applications, fundamental questions remain about baseline viscoelastic properties of the brainin vivo. Furthermore, the underlying mechanisms of how and why elastographic measures can change over time are still not well understood. To study these issues, reverberant shear wave elastography using an optical coherence tomography scanner is implemented on a mouse model, both under awake conditions and in a sleep state where there are known changes in the glymphatic fluid flow system in the brain. We find that shear wave speed, a measure of stiffness, changes by approximately 12% between the two states, sleep versus awake, in the entire cortical brain imaging volume. Our microchannel flow model of biphasic (fluid plus solid) tissue provides a plausible rheological model based on the fractal branching vascular and perivascular system, plus a second parallel system representing the finer scale glymphatic fluid microchannels. By adjusting the glymphatic system fluid volume proportional to the known sleep/wake changes, we are able to approximately predict the measured shear wave speeds and their change with the state of the glymphatic system. The advantages of this model are that its main parameters are derived from anatomical measures and are linked to other major derivations of branching fluid structures including Murray's Law. The implications for clinical studies are that elastography of the brain is strongly influenced by the regulation or dysregulation of the vascular, perivascular, and glymphatic systems.
Collapse
|
12
|
Comprehensive experimental assessments of rheological models' performance in elastography of soft tissues. Acta Biomater 2022; 146:259-273. [PMID: 35525481 DOI: 10.1016/j.actbio.2022.04.047] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2022] [Revised: 04/26/2022] [Accepted: 04/28/2022] [Indexed: 02/08/2023]
Abstract
Elastography researchers have utilized several rheological models to characterize soft tissue viscoelasticity over the past thirty years. Due to the frequency-dependent behavior of viscoelastic parameters as well as the different techniques and frequencies employed in various studies of soft tissues, rheological models have value in standardizing disparate techniques via explicit mathematical representations. However, the important question remains: which of the several available models should be considered for widespread adoption within a theoretical framework? We address this by evaluating the performance of three well established rheological models to characterize ex vivo bovine liver tissues: the Kelvin-Voigt (KV) model as a 2-parameter model, and the standard linear solid (SLS) and Kelvin-Voigt fractional derivative (KVFD) models as 3-parameter models. The assessments were based on the analysis of time domain behavior (using stress relaxation tests) and frequency domain behavior (by measuring shear wave speed (SWS) dispersion). SWS was measured over a wide range of frequency from 1 Hz to 1 kHz using three different tests: (i) harmonic shear tests using a rheometer, (ii) reverberant shear wave (RSW) ultrasound elastography scans, and (iii) RSW optical coherence elastography scans, with each test targeting a distinct frequency range. Our results demonstrated that the KVFD model produces the only mutually consistent rendering of time and frequency domain data for liver. Furthermore, it reduces to a 2-parameter model for liver (correspondingly to a 2-parameter "spring-pot" or power-law model for SWS dispersion) and provides the most accurate predictions of the material viscoelastic behavior in time (>98% accuracy) and frequency (>96% accuracy) domains. STATEMENT OF SIGNIFICANCE: Rheological models are applied in quantifying tissues viscoelastic properties. This study is unique in presenting comprehensive assessments of rheological models.
Collapse
|
13
|
Abstract
Major topics in medical ultrasound rest on the physics of wave propagation through tissue. These include fundamental treatments of backscatter, speed of sound, attenuation, and speckle formation. Each topic has developed its own rich history, lexicography, and particular treatments. However, there is ample evidence to suggest that power law relations are operating at a fundamental level in all the basic phenomena related to medical ultrasound. This review paper develops, from literature over the past 60 years, the accumulating theoretical basis and experimental evidence that point to power law behaviors underlying the most important tissue-wave interactions in ultrasound and in shear waves which are now employed in elastography. The common framework of power laws can be useful as a coherent overview of topics, and as a means for improved tissue characterization.
Collapse
|
14
|
Generalized formulations producing a Burr distribution of speckle statistics. J Med Imaging (Bellingham) 2022; 9:023501. [PMID: 35387205 PMCID: PMC8973393 DOI: 10.1117/1.jmi.9.2.023501] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Accepted: 01/31/2022] [Indexed: 11/14/2022] Open
Abstract
Purpose: The study of speckle from imaging systems has a rich history, and recently it was proposed that a fractal or power law distribution of scatterers in vascularized tissue will lead to a form of the Burr probability distribution functions for speckle amplitudes. This hypothesis is generalized and tested in theory, simulations, and experiments. Approach: We argue that two broadly applicable conjectures are sufficient to justify the applicability of the Burr distribution for speckle from a number of acoustical, optical, and other pulse-echo systems. The first requirement is a multiscale power law distribution of weak scatterers, and the second is a linear approximation for the increase in echo intensity with size over some range of applicability. Results: The Burr distribution for speckle emerges under a wide variety of conditions and system parameters, and from this one can estimate the governing power law parameter, commonly in the range of 2 to 6. However, system effects including the imaging point spread function and the degree of focusing will influence the Burr parameters. Conclusions: A generalized pair of conditions is sufficient for producing Burr distributions across a number of imaging systems. Simulations and some theoretical considerations indicate that the estimated Burr power law parameter will increase with increasing density of scatters. For studies of speckle from living tissue or multiscale natural structures, the Burr distribution should be considered as a long tail alternative to classical distributions.
Collapse
|
15
|
A Preliminary Study of Liver Fat Quantification Using Reported Ultrasound Speed of Sound and Attenuation Parameters. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:675-684. [PMID: 35039191 DOI: 10.1016/j.ultrasmedbio.2021.12.009] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Revised: 12/07/2021] [Accepted: 12/08/2021] [Indexed: 06/14/2023]
Abstract
The quantification of liver fat as a diagnostic assessment of steatosis remains an important priority for non-invasive imaging systems. We derive a framework in which the unknown fat volume percentage can be estimated from a pair of ultrasound measurements. The precise estimation of ultrasound speed of sound and attenuation within the liver is found to be sufficient for estimating fat volume assuming a classic model of the properties of a composite elastic material. In this model, steatosis is represented as a random dispersion of spherical fat vacuoles with acoustic properties similar to those of edible oils. Using values of speed of sound and attenuation from the literature in which normal and steatotic livers were studied near 3.5 MHz, we describe agreement of the new estimation method with independent measures of fat. This framework holds the potential for translation to clinical scanners with which the two ultrasound measurements can be made and used for improved quantitative assessment of steatosis.
Collapse
|
16
|
Local Burr distribution estimator for speckle statistics. BIOMEDICAL OPTICS EXPRESS 2022; 13:2334-2345. [PMID: 35519249 PMCID: PMC9045934 DOI: 10.1364/boe.451307] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Revised: 02/10/2022] [Accepted: 03/08/2022] [Indexed: 06/14/2023]
Abstract
Speckle statistics in ultrasound and optical coherence tomography have been studied using various distributions, including the Rayleigh, the K, and the more recently proposed Burr distribution. In this paper, we expand on the utility of the Burr distribution by first validating its theoretical framework with numerical simulations and then introducing a new local estimator to characterize sample tissues of liver, brain, and skin using optical coherence tomography. The spatially local estimates of the Burr distribution's power-law or exponent parameter enable a new type of parametric image. The simulation and experimental results confirm the potential for various applications of the Burr distribution in both basic science and clinical realms.
Collapse
|
17
|
Disease-Specific Imaging Utilizing Support Vector Machine Classification of H-Scan Parameters: Assessment of Steatosis in a Rat Model. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:720-731. [PMID: 34936555 PMCID: PMC8908945 DOI: 10.1109/tuffc.2021.3137644] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
In medical imaging, quantitative measurements have shown promise in identifying diseases by classifying normal versus pathological parameters from tissues. The support vector machine (SVM) has shown promise as a supervised classification algorithm and has been widely used. However, the classification results typically identify a category of abnormal tissues but do not necessarily differentiate progressive stages of a disease. Moreover, the classification result is typically provided independently as a supplement to medical images, which contributes to an overload of information sources in the clinic. Hence, we propose a new imaging method utilizing the SVM to integrate classification results into medical images. This framework is called disease-specific imaging (DSI) that produces a color overlaid highlight on B-mode ultrasound images indicating the type, location, and severity of pathology from different conditions. In this article, the SVM training was performed to construct hyperplanes that can differentiate normal, fibrosis, steatosis, and pancreatic ductal adenocarcinoma (PDAC) metastases in livers based on ultrasound echoes. Also, cluster centroids for specific diseases define unique disease axes, and the inner product between measured features and any disease axis selected by the SVM quantifies the disease progression. The features were measured from 2794 ultrasound frames using the H-scan analysis, attenuation estimation, and B-mode image analysis. The performance of our proposed DSI method was evaluated for a preclinical model of steatosis ( n = 400 frames). The contribution of each feature was assessed, and the results were compared with ground truth from histology. Moreover, the images generated by our DSI were compared with earlier imaging methods of B-mode, H-scan, and histology. The comparisons demonstrate that DSI images yield higher sensitivity to monitor progressive steatosis than B-mode and H-scan and provide a comparable performance with the histology. For the parameter comparison, DSI and H-scan resulted in similar correlation with histology ( rs = 0.83 ) but higher than attenuation ( rs = 0.73 ) and B-mode ( rs = 0.47 ). Therefore, we conclude that DSI utilizing the SVM applied to steatosis can visually represent the classification results with color highlighting, which can simplify the interpretation of classification compared to the traditional SVM result. We expect that the proposed DSI can be used for any medical imaging modality that can estimate multiple quantitative parameters at high resolution.
Collapse
|
18
|
Assessing corneal cross-linking with reverberant 3D optical coherence elastography. JOURNAL OF BIOMEDICAL OPTICS 2022; 27:026003. [PMID: 35166086 PMCID: PMC8843360 DOI: 10.1117/1.jbo.27.2.026003] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/12/2021] [Accepted: 01/27/2022] [Indexed: 06/14/2023]
Abstract
SIGNIFICANCE Corneal cross-linking (CXL) is a well-known procedure for treating certain eye disorders such as keratoconus. However, characterization of the biomechanical changes in the cornea as a result of this procedure is still under active research. Specifically, there is a clinical need for high-resolution characterization of individual corneal layers. AIM A high-resolution elastography method in conjunction with a custom optical coherence tomography system is used to track these biomechanical changes in individual corneal layers. Pre- and post-treatment analysis for both low-dose and high-dose CXL experiments are performed. APPROACH A recently developed elastography technique that utilizes the theory of reverberant shear wave fields, with optical coherence tomography as the modality, is applied to pig corneas ex vivo to evaluate elasticity changes associated with corneal CXL. Sets of low-dose and high-dose CXL treatments are evaluated before and after treatments with three pairs of pig corneas per experiment. RESULTS The reverberant three-dimensional (3D) optical coherence elastography (OCE) technique can identify increases in elasticity associated with both low-dose and high-dose CXL treatments. There is a notable graphical difference between low-dose and high-dose treatments. In addition, the technique is able to identify which layers of the cornea are potentially affected by the CXL procedure and provides insight into the nonlinearity of the elasticity changes. CONCLUSIONS The reverberant 3D OCE technique can identify depth-resolved changes in elasticity of the cornea associated with CXL procedures. This method could be translated to assess and monitor CXL efficacy in various clinical settings.
Collapse
|
19
|
Diagnostic Performance of an Artificial Intelligence System in Breast Ultrasound. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2022; 41:97-105. [PMID: 33665833 DOI: 10.1002/jum.15684] [Citation(s) in RCA: 20] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/03/2020] [Revised: 02/17/2021] [Accepted: 02/18/2021] [Indexed: 05/26/2023]
Abstract
OBJECTIVES We study the performance of an artificial intelligence (AI) program designed to assist radiologists in the diagnosis of breast cancer, relative to measures obtained from conventional readings by radiologists. METHODS A total of 10 radiologists read a curated, anonymized group of 299 breast ultrasound images that contained at least one suspicious lesion and for which a final diagnosis was independently determined. Separately, the AI program was initialized by a lead radiologist and the computed results compared against those of the radiologists. RESULTS The AI program's diagnoses of breast lesions had concordance with the 10 radiologists' readings across a number of BI-RADS descriptors. The sensitivity, specificity, and accuracy of the AI program's diagnosis of benign versus malignant was above 0.8, in agreement with the highest performing radiologists and commensurate with recent studies. CONCLUSION The trained AI program can contribute to accuracy of breast cancer diagnoses with ultrasound.
Collapse
|
20
|
Design and Analysis Methods for Trials with AI-Based Diagnostic Devices for Breast Cancer. J Pers Med 2021; 11:jpm11111150. [PMID: 34834502 PMCID: PMC8617855 DOI: 10.3390/jpm11111150] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Revised: 11/02/2021] [Accepted: 11/02/2021] [Indexed: 11/24/2022] Open
Abstract
Imaging is important in cancer diagnostics. It takes a long period of medical training and clinical experience for radiologists to be able to accurately interpret diagnostic images. With the advance of big data analysis, machine learning and AI-based devices are currently under development and taking a role in imaging diagnostics. If an AI-based imaging device can read the image as accurately as experienced radiologists, it may be able to help radiologists increase the accuracy of their reading and manage their workloads. In this paper, we consider two potential study objectives of a clinical trial to evaluate an AI-based device for breast cancer diagnosis by comparing its concordance with human radiologists. We propose statistical design and analysis methods for each study objective. Extensive numerical studies are conducted to show that the proposed statistical testing methods control the type I error rate accurately and the design methods provide required sample sizes with statistical powers close to pre-specified nominal levels. The proposed methods were successfully used to design and analyze a real device trial.
Collapse
|
21
|
Abstract
The microchannel flow model postulates that stress-strain behavior in soft tissues is influenced by the time constants of fluid-filled vessels related to Poiseuille’s law. A consequence of this framework is that changes in fluid viscosity and changes in vessel diameter (through vasoconstriction) have a measurable effect on tissue stiffness. These influences are examined through the theory of the microchannel flow model. Then, the effects of viscosity and vasoconstriction are demonstrated in gelatin phantoms and in perfused tissues, respectively. We find good agreement between theory and experiments using both a simple model made from gelatin and from living, perfused, placental tissue ex vivo.
Collapse
|
22
|
Clusters of Ultrasound Scattering Parameters for the Classification of Steatotic and Normal Livers. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:3014-3027. [PMID: 34315619 PMCID: PMC8445071 DOI: 10.1016/j.ultrasmedbio.2021.06.010] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2020] [Revised: 06/03/2021] [Accepted: 06/17/2021] [Indexed: 05/08/2023]
Abstract
The study of ultrasound tissue interactions in fatty livers has a long history with strong clinical potential for assessing steatosis. Recently we proposed alternative measures of first- and second-order statistics of echoes from soft tissues, namely, the H-scan, which is based on a matched filter approach, to quantify scattering transfer functions and the Burr distribution to model speckle patterns. Taken together, these approaches produce a multiparameter set that is directly related to the fundamentals of ultrasound propagation in tissue. To apply this approach to the problem of assessing steatotic livers, these analyses were applied to in vivo rat livers (N=21) under normal feeding conditions or after receiving a methionine- and choline-deficient diet that produces steatosis within a few weeks. Ultrasound data were acquired at baseline and again at weeks 2 and 6 before applying the H-scan and Burr analyses. Furthermore, a classification technique known as the support vector machine was then used to find clusters of the five parameters that are characteristic of the different steatotic liver conditions as confirmed by histologic processing of excised liver tissue samples. With the in vivo multiparametric ultrasound measurement approach and determination of clusters, steatotic can be discriminated from normal livers with 100% accuracy in a rat animal model.
Collapse
|
23
|
Reverberant shear wave phase gradients for elastography. Phys Med Biol 2021; 66. [PMID: 34359063 DOI: 10.1088/1361-6560/ac1b37] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2021] [Accepted: 08/06/2021] [Indexed: 12/19/2022]
Abstract
Reverberant shear wave fields are produced when multiple sources and multiple reflections establish a complex three-dimensional wave field within an organ. The expected values are assumed to be isotropic across all directions and the autocorrelation functions for velocity are expressed in terms of spherical Bessel functions. These results provide the basis for adroit implementations of elastography from imaging systems that can map out the internal velocity or displacement of tissues during reverberant field excitations. By examining the phase distribution of the reverberant field, additional estimators can be derived. In particular, we demonstrate that the reverberantphase gradientis shown to be proportional to the local value of wavenumber. This phase estimator is less sensitive to imperfections in the reverberant field distribution and requires a smaller support window, relative to earlier estimators based on autocorrelation. Applications are shown in simulations, phantoms, andin vivoliver.
Collapse
|
24
|
H-scan trajectories indicate the progression of specific diseases. Med Phys 2021; 48:5047-5058. [PMID: 34287952 DOI: 10.1002/mp.15108] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2021] [Revised: 07/09/2021] [Accepted: 07/12/2021] [Indexed: 01/18/2023] Open
Abstract
PURPOSE The ability of ultrasound to assess pathology is increasing with the development of quantitative parameters. Among these are a set of parameters derived from the recent H-scan analysis of subresolvable scattering. The emergence of these quantitative measures of tissue/ultrasound interactions now enables a study of the unique trajectories of multiparametric features in multidimensional space, representing the progression of specific diseases over time. We develop the mathematical and visual tools that are effective for classifying, quantifying, and visualizing the steady progression of several diseases from independent studies, all within a uniform framework. METHODS After applying the H-scan analysis of ultrasound echoes, we trained a support vector machine (SVM) to classify the unique trajectories of progressive liver disease from fibrosis, steatosis, and pancreatic ductal adenocarcinoma (PDAC) metastasis. Our approaches include the development of trajectory maps and disease-specific color imaging stains. RESULTS The multidimensional SVM image classification reached 100% accuracy across the three different studies. CONCLUSION H-scan trajectories can be useful to track the progression of multiple classes of diseases, improving diagnosis, staging, and assessing the response to therapy.
Collapse
|
25
|
The quantification of liver fat from wave speed and attenuation. Phys Med Biol 2021; 66. [PMID: 34192672 DOI: 10.1088/1361-6560/ac1023] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2021] [Accepted: 06/30/2021] [Indexed: 12/19/2022]
Abstract
A framework is developed for estimating the volume fraction of fat in steatotic livers from viscoelastic measures of shear wave speed and attenuation. These measures are emerging on clinical ultrasound systems' elastography options so this approach can become widely available for assessing and monitoring steatosis. The framework assumes a distribution of fat vesicles as spherical inhomogeneities within the liver and uses a composite rheological model (Christensen 1969J. Mech. Phys. Solids1723-41) to determine the shear modulus as a function of increasing volume of fat within the liver. We show that accurate measurements of shear wave speed and attenuation provide the necessary and sufficient information to solve for the unknown fat volume and the underlying liver stiffness. Extension of the framework to compression wave measurements is also possible. Data from viscoelastic phantoms, human liver studies, and steatotic animal livers are shown to provide reasonable estimates of the volume fraction of fat.
Collapse
|
26
|
Speckle statistics of biological tissues in optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2021; 12:4179-4191. [PMID: 34457407 PMCID: PMC8367221 DOI: 10.1364/boe.422765] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Revised: 05/02/2021] [Accepted: 06/11/2021] [Indexed: 06/13/2023]
Abstract
The speckle statistics of optical coherence tomography images of biological tissue have been studied using several historical probability density functions. Here, we propose a new theoretical framework based on power-law functions, where we hypothesize that an underlying power-law distribution governs scattering from tissues. Thus, multi-scale scattering sites including the fractal branching vasculature will contribute to power-law probability distributions of speckle statistics. Specifically, these are the Burr type XII distribution for speckle amplitude, the Lomax distribution for intensity, and the generalized logistic distribution for log amplitude. Experimentally, these three distributions are fitted to histogram data from nine optical coherence tomography scans of various samples and biological tissues, in vivo and ex vivo. The distributions are also compared with classical models such as the Rayleigh, K, and gamma distributions. The results indicate that across OCT datasets of various tissue types, the proposed power-law distributions are more appropriate models yielding novel parameters for characterizing the physics of scattering from biological tissue. Thus, the overall framework brings to the field new biomarkers from OCT measures of speckle in tissues, grounded in basic biophysics and with wide applications to diagnostic imaging in clinical use.
Collapse
|
27
|
Abstract
Elastography provides significant information on staging of fibrosis in patients with liver disease and may be of some value in assessing steatosis. However, there remain questions as to the role of steatosis and fibrosis as cofactors influencing the viscoelastic measurements of liver tissues, particularly shear wave speed (SWS) and shear wave attenuation (SWA). In this study, by employing the theory of composite elastic media as well as two independent experimental measurements on oil-in-gelatin phantoms and also finite element simulations, it is consistently shown that fat and fibrosis jointly influence the SWS and SWA measurements. At a constant level of fat, fibrosis stages can influence the SWA by factors of 2-4. Moreover, the rate of increase in SWA with increasing fat is strongly influenced by the stages of fibrosis; softer background cases (low fibrosis stages) have higher rate of SWA increase with fat than those with stiffer moduli (higher fibrosis stages). Meanwhile, SWS results are influenced by the presence of fat, however the degree of variability is more subtle. The results indicate the importance of jointly considering fat and fibrosis as contributors to SWS and SWA measurements in complex liver tissues and in the design and interpretation of clinical trials.
Collapse
|
28
|
Multiparametric ultrasound imaging for the assessment of normal versus steatotic livers. Sci Rep 2021; 11:2655. [PMID: 33514796 PMCID: PMC7846566 DOI: 10.1038/s41598-021-82153-z] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2020] [Accepted: 01/15/2021] [Indexed: 12/13/2022] Open
Abstract
Liver disease is increasing in prevalence across the globe. We present here a multiparametric ultrasound (mpUS) imaging approach for assessing nonalcoholic fatty liver disease (NALFD). This study was performed using rats (N = 21) that were fed either a control or methionine and choline deficient (MCD) diet. A mpUS imaging approach that includes H-scan ultrasound (US), shear wave elastography, and contrast-enhanced US measurements were then performed at 0 (baseline), 2, and 6 weeks. Thereafter, animals were euthanized and livers excised for histological processing. A support vector machine (SVM) was used to find a decision plane that classifies normal and fatty liver conditions. In vivo mpUS results from control and MCD diet fed animals reveal that all mpUS measures were different at week 6 (P < 0.05). Principal component analysis (PCA) showed that the H-scan US data contributed the highest percentage to the classification among the mpUS measurements. The SVM resulted in 100% accuracy for classification of normal and high fat livers and 92% accuracy for classification of normal, low fat, and high fat livers. Histology findings found considerable steatosis in the MCD diet fed animals. This study suggests that mpUS examinations have the potential to provide a comprehensive estimation of the main components of early stage NAFLD.
Collapse
|
29
|
Scattering Signatures of Normal versus Abnormal Livers with Support Vector Machine Classification. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:3379-3392. [PMID: 32917469 PMCID: PMC9386788 DOI: 10.1016/j.ultrasmedbio.2020.08.009] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/11/2020] [Revised: 07/30/2020] [Accepted: 08/06/2020] [Indexed: 05/14/2023]
Abstract
Fifty years of research on the nature of backscatter from tissues has resulted in a number of promising diagnostic parameters. We recently introduced two analyses tied directly to the biophysics of ultrasound scattering: the H-scan, based on a matched filter approach to distinguishing scattering transfer functions, and the Burr distribution for quantification of speckle patterns. Together, these analyses can produce at least five parameters that are directly linked to the mathematics of ultrasound in tissue. These have been measured in vivo in 35 rat livers under normal conditions and after exposure to compounds that induce inflammation, fibrosis, and steatosis in varying combinations. A classification technique, the support vector machine, is employed to determine clusters of the five parameters that are signatures of the different liver conditions. With the multiparametric measurement approach and determination of clusters, the different types of liver pathology can be discriminated with 94.6% accuracy.
Collapse
|
30
|
Comprehensive Viscoelastic Characterization of Tissues and the Inter-relationship of Shear Wave (Group and Phase) Velocity, Attenuation and Dispersion. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:3448-3459. [PMID: 32988669 DOI: 10.1016/j.ultrasmedbio.2020.08.023] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Revised: 08/21/2020] [Accepted: 08/22/2020] [Indexed: 06/11/2023]
Abstract
We report shear wave phase and group velocity, dispersion and attenuation in oil-in-gelatin viscoelastic phantoms and in vivo liver data. Moreover, we measured the power law coefficient from each dispersion curve and used it, together with the shear wave velocity, to calculate an approximate value for attenuation that agrees with independent attenuation measurements. Results in phantoms exhibit good agreement for all parameters with respect to independent mechanical measurements. For in vivo data, the livers of 20 patients were scanned. Results were compared with pathology scores obtained from liver biopsies. Across these cases, increases in shear wave dispersion and attenuation were related to increased steatosis score. It was found that shear wave dispersion and attenuation are experimentally linked, consistent with simple predictions based on the rheology of tissues, and can be used individually or jointly to assess tissue viscosity. Thus, this study indicates the possible utility of using shear wave dispersion and attenuation to non-invasively and quantitatively assess steatosis.
Collapse
|
31
|
H-scan, Shear Wave and Bioluminescent Assessment of the Progression of Pancreatic Cancer Metastases in the Liver. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:3369-3378. [PMID: 32907773 PMCID: PMC9066934 DOI: 10.1016/j.ultrasmedbio.2020.08.006] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2020] [Revised: 08/04/2020] [Accepted: 08/05/2020] [Indexed: 05/24/2023]
Abstract
The non-invasive quantification of tumor burden and the response to therapies remain an important objective for imaging modalities. To characterize the performance of two newly optimized ultrasound-based analyses, we applied shear wave and H-scan scattering analyses to repeated trans-abdominal ultrasound scans of a murine model of metastatic pancreatic cancer. In addition, bioluminescence measurements were obtained as an alternative reference. The tumor metastases grow aggressively and result in death at approximately 4 wk if untreated, but longer for those treated with chemotherapy. We found that our three imaging methods (shear wave speed, H-scan, bioluminescence) trended toward increasing output measures with time during tumor growth, and these measures were delayed for the group receiving chemotherapy. The relative sensitivity of H-scan tracked closely with bioluminescence measurements, particularly in the early to mid-stages of tumor growth. The correlation between H-scan and bioluminescence was found to be strong, with a Spearman's rank correlation coefficient greater than 0.7 across the entire series. These preliminary results suggest that non-invasive ultrasound imaging analyses are capable of tracking the response of tumor models to therapeutic agents.
Collapse
|
32
|
Abstract
From the development of X-ray imaging in the late 19th century, the field of medical imaging developed an impressive array of modalities. These can measure and image a variety of physical parameters from absorption coefficients to spin-spin relaxations. However, throughout most of the 20th century, the intrinsic biomechanical properties of tissues remained hidden from conventional radiology. This changed around 1990 when it was demonstrated that medical ultrasound systems with their fast pulse repetition rate and high sensitivity to motion could create images related to the stiffness of tissues and their shear wave properties. From there, vigorous development efforts towards imaging the elastic properties of tissues were launched across different modalities. These progressed from the research phase, through implementation on clinical scanners, through extensive clinical trials of selected diagnostic tasks, to government approvals, payer approvals, international standards statements, and into routine clinical practice around the globe. This review covers highlights of some major topics of the technical and clinical developments over the last 30 years with brief pointers to some of the remaining issues for the next decade of development.
Collapse
|
33
|
IP Infringement. TECHNOLOGY AND INNOVATION 2020. [DOI: 10.21300/21.3.2020.203] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
34
|
Infringement Battles: A Case Study Illustrates The Need for Reforms. TECHNOLOGY AND INNOVATION 2020. [DOI: 10.21300/21.3.2020.237] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
We present a case of a university invention and the long, costly legal process that was required to challenge prominent infringing products. This history highlights a number of areas where reforms are urgently needed so that small entities can defend their intellectual property with
realistic budgets, timelines, and solid facts—and without baseless recriminations. A call for coordinated action is made to restore the ability of the National Academy of Inventors members and other inventors and small entities to access the law in defense of issued patents.
Collapse
|
35
|
Abstract
After 100 years of theoretical treatment of speckle patterns from coherent illumination, there remain some open questions about the nature of ultrasound speckle from soft vascularized tissues. A recent hypothesis is that the fractal branching vasculature is responsible for the dominant echo pattern from organs such as the liver. In that case, an analysis of cylindrical scattering structures arranged across a power law distribution of sizes is warranted. Using a simple model of echo strength and basic transformation rules from probability, we derive the first order statistics of speckle considering the amplitude, the intensity, and the natural log of amplitude. The results are given by long tailed distributions that have been studied in the statistics literature for other fields. Examples are given from simulations and animal studies, and the theoretical fit to these preliminary data support the overall framework as a plausible model for characterizing ultrasound speckle statistics.
Collapse
|
36
|
Abstract
The H-scan approach ('H' denoting hue, or Hermite) is a recent matched filter methodology that aims to add information to the traditional ultrasound B-scan. The theory is based on the differences in the echoes produced by different classes of reflectors or scatterers. Matched filters can be created for different types of scatterers, whereby the maximum output indicates a match, and color schemes can be used to indicate the class of scatterer responsible for echoes, providing a visual interpretation of the results. However, within the theory of weak scattering from a variety of shapes, small changes in the size of the inhomogeneous objects will create shifts in the scattering transfer function. In this paper, we argue for a general power law transfer function as the canonical model for transfer functions from most normal soft vascularized tissues, at least over some bandpass spectrum illuminated by the incident pulse. In cases where scatterer size and distributions change, this produces a corresponding shift in center frequency, along with time and frequency domain characteristics of echoes, and these are captured by matched filters to distinguish and visualize in color the major characteristics of scattering types. With this general approach, the H-scan matched filters can be set to elicit more fine grain shifts in scattering types, commensurate with more subtle changes in tissue morphology. Compensation for frequency-dependent attenuation is helpful for avoiding beam softening effects with increasing depths. Examples from phantoms and normal and pathological tissues are provided to demonstrate that the H-scan analysis and displays are sensitive to scatterer size and morphology, and can be adapted to conventional imaging systems.
Collapse
|
37
|
Speckle from branching vasculature: dependence on number density. J Med Imaging (Bellingham) 2020; 7:027001. [PMID: 32313816 DOI: 10.1117/1.jmi.7.2.027001] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2019] [Accepted: 03/23/2020] [Indexed: 11/14/2022] Open
Abstract
Purpose: Recent theories examine the role of the fractal branching vasculature as a primary site of Born scattering from soft normal tissues. These derivations postulate that the first-order statistics of speckle from soft tissue, such as the liver, thyroid, and prostate, will follow a Burr distribution with a power law parameter that can be related back to the underlying power law, which governs the branching network. However, the issue of scatterer spacing, or the number of cylindrical vessels per sample volume of the interrogating pulse, has not been directly addressed. Approach: Speckle statistics are examined with a 3D simulation that varies the number density and the governing power law parameter of an ensemble of different sized cylinders. Several in vivo liver scans are also analyzed for confirmation across different conditions. Results: The Burr distribution is found to be an appropriate model for the histogram of amplitudes from speckle regions, where the parameters track the underlying power law and scatterer density conditions. These results are also tested in a more general model of rat liver scans in normal versus abnormal conditions, and the resulting Burr parameters are also found to be appropriate and sensitive to underlying scatterer distributions. Conclusions: These preliminary results suggest that the classical Burr distribution may be useful in the quantification of scattering of ultrasound from soft vascularized tissues and as a tool in tissue characterization.
Collapse
|
38
|
The first order statistics of backscatter from the fractal branching vasculature. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2019; 146:3318. [PMID: 31795650 PMCID: PMC6853797 DOI: 10.1121/1.5132934] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/30/2019] [Revised: 09/06/2019] [Accepted: 10/14/2019] [Indexed: 05/08/2023]
Abstract
The issue of speckle statistics from ultrasound images of soft tissues such as the liver has a long and rich history. A number of theoretical distributions, some related to random scatterers or fades in optics and radar, have been formulated for pulse-echo interference patterns. This work proposes an alternative framework in which the dominant echoes are presumed to result from Born scattering from fluid-filled vessels that permeate the tissue parenchyma. These are modeled as a branching, fractal, self-similar, multiscale collection of cylindrical scatterers governed by a power law distribution relating to the number of branches at each radius. A deterministic accounting of the echo envelopes across the scales from small to large is undertaken, leading to a closed form theoretical formula for the histogram of the envelope of the echoes. The normalized histogram is found to be related to the classical Burr distribution, with the key power law parameter directly related to that of the number density of vessels vs diameter, frequently reported in the range of 2 to 4. Examples are given from liver scans to demonstrate the applicability of the theory.
Collapse
|
39
|
Abstract
A rising wave of technologies and instruments are enabling more labs and clinics to make a variety of measurements related to tissue viscoelastic properties. These instruments include elastography imaging scanners, rheological shear viscometers, and a variety of calibrated stress-strain analyzers. From these many sources of disparate data, a common step in analyzing results is to fit the measurements of tissue response to some viscoelastic model. In the best scenario, this places the measurements within a theoretical framework and enables meaningful comparisons of the parameters against other types of tissues. However, there is a large set of established rheological models, even within the class of linear, causal, viscoelastic solid models, so which of these should be chosen? Is it simply a matter of best fit to a minimum mean squared error of the model to several data points? We argue that the long history of biomechanics, including the concept of the extended relaxation spectrum, along with data collected from viscoelastic soft tissues over an extended range of times and frequencies, and the theoretical framework of multiple relaxation models which model the multi-scale nature of physical tissues, all lead to the conclusion that fractional derivative models represent the most succinct and meaningful models of soft tissue viscoelastic behavior. These arguments are presented with the goal of clarifying some distinctions between, and consequences of, some of the most commonly used models, and with the longer term goal of reaching a consensus among different sub-fields in acoustics, biomechanics, and elastography that have common interests in comparing tissue measurements.
Collapse
|
40
|
Reverberant 3D optical coherence elastography maps the elasticity of individual corneal layers. Nat Commun 2019; 10:4895. [PMID: 31653846 PMCID: PMC6814807 DOI: 10.1038/s41467-019-12803-4] [Citation(s) in RCA: 48] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2019] [Accepted: 09/24/2019] [Indexed: 12/01/2022] Open
Abstract
The elasticity mapping of individual layers in the cornea using non-destructive elastography techniques advances diagnosis and monitoring of ocular diseases and treatments in ophthalmology. However, transient Lamb waves, currently used in most dynamic optical coherence and ultrasound elastography techniques, diminish the translation of wave speed into shear/Young’s modulus. Here, we present reverberant 3D optical coherence elastography (Rev3D-OCE), a novel approach leveraging the physical properties of diffuse fields in detecting elasticity gradients not only in the lateral direction, but also along the depth axis of the cornea. A Monte Carlo analysis, finite element simulations, and experiments in layered phantoms are conducted to validate the technique and to characterize the axial elastography resolution. Experiments in ex vivo porcine cornea at different intraocular pressures reveal that Rev3D-OCE enables the elastic characterization of single layers that matches the anatomical description of corneal layers with unprecedented contrast in the dynamic OCE field. Elastic mapping of individual layers of the cornea with elastography uses Lamb waves, which are dependent on the thickness of each layer and the direction of propagation. Here the authors present Reverberant 3D Optical Coherence Elastography to measure elasticity of single layers using waves propagating in all directions.
Collapse
|
41
|
Abstract
What causes scattering of ultrasound from normal soft tissues such as the liver, thyroid, and prostate? Commonly, the answer is formulated around the properties of spherical scatterers, related to cellular shapes and sizes. However, an alternative view is that the closely packed cells forming the tissue parenchyma create the reference media, and the long cylindrical-shaped fluid vessels serve as the scattering sites. Under a weak scattering or Born approximation for the extracellular fluid in the vessels, and assuming an isotropic distribution of cylindrical channels across a wide range of diameters, consistent with a fractal branching pattern, some simple predictions can be made about the nature of backscatter as a function of frequency in soft tissues. Specifically, a number of plausible shapes would predict that backscatter increases as a power law of frequency, where the power law is determined by the function governing the number density of the vessels versus diameter. These results are compared with some historical models developed over the last 100 years in scattering theory and point to the need for higher spatial resolution and higher bandwidths to obtain more precise measures of the key parameters in normal tissues, and to better identify the dominant structures responsible for backscatter in everyday clinical imaging.
Collapse
|
42
|
An initial study of complete 2D shear wave dispersion images using a reverberant shear wave field. ACTA ACUST UNITED AC 2019; 64:145009. [DOI: 10.1088/1361-6560/ab2778] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
43
|
Longitudinal shear waves for elastic characterization of tissues in optical coherence elastography. BIOMEDICAL OPTICS EXPRESS 2019; 10:3699-3718. [PMID: 31360610 PMCID: PMC6640829 DOI: 10.1364/boe.10.003699] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/08/2019] [Revised: 05/30/2019] [Accepted: 06/11/2019] [Indexed: 05/10/2023]
Abstract
In dynamic optical coherence elastography (OCE), surface acoustic waves are the predominant perturbations. They constrain the quantification of elastic modulus to the direction of wave propagation only along the surface of tissues, and disregard elasticity gradients along depth. Longitudinal shear waves (LSW), on the other hand, can be generated at the surface of the tissue and propagate through depth with desirable properties for OCE: (1) LSW travel at the shear wave speed and can discriminate elasticity gradients along depth, and (2) the displacement of LSW is longitudinally polarized along the direction of propagation; therefore, it can be measured by a phase-sensitive optical coherence tomography system. In this study, we explore the capabilities of LSW generated by a circular glass plate in contact with a sample using numerical simulations and tissue-mimicking phantom experiments. Results demonstrate the potential of LSW in detecting an elasticity gradient along axial and lateral directions simultaneously. Finally, LSW are used for the elastography of ex vivo mouse brain and demonstrate important implications in in vivo and in situ measurements of local elasticity changes in brain and how they might correlate with the onset and progression of degenerative brain diseases.
Collapse
|
44
|
Monitoring Early Breast Cancer Response to Neoadjuvant Therapy Using H-Scan Ultrasound Imaging: Preliminary Preclinical Results. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2019; 38:1259-1268. [PMID: 30280391 PMCID: PMC6445796 DOI: 10.1002/jum.14806] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2018] [Accepted: 07/22/2018] [Indexed: 05/10/2023]
Abstract
OBJECTIVE H-scan imaging is a new ultrasound technique used to visualize the relative size of acoustic scatterers. The purpose of this study was to evaluate the use of H-scan ultrasound imaging for monitoring early tumor response to neoadjuvant treatment using a preclinical breast cancer animal model. METHODS Real-time H-scan ultrasound imaging was implemented on a programmable ultrasound scanner (Vantage 256; Verasonics Inc., Kirkland, WA) equipped with an L11-4v transducer. Bioluminescence and H-scan ultrasound was used to image luciferase-positive breast cancer-bearing mice at baseline and at 24, 48, and 168 hours after administration of a single dose of neoadjuvant (paclitaxel) or sham treatment. Animals were euthanized at 48 or 168 hours, and tumors underwent histologic processing to identify cancer cell proliferation and apoptosis. RESULTS Baseline H-scan ultrasound images of control and therapy group tumors were comparable, but the latter exhibited significant changes over the 7-day study (P < .05). At termination, there was a marked difference between the H-scan ultrasound images of control and treated tumors (P < .05). Specifically, H-scan ultrasound images of treated tumors were more blue in hue than images obtained from control tumors. There was a significant linear correlation between the predominance of the blue hue found in the H-scan ultrasound images and intratumoral apoptotic activity (R2 > 0.40, P < .04). CONCLUSION Preliminary preclinical results suggest that H-scan ultrasound imaging is a new and promising tissue characterization modality. H-scan ultrasound imaging may provide prognostic value when monitoring early tumor response to neoadjuvant treatment.
Collapse
|
45
|
Abstract
The fractal branching vasculature within soft tissues and the mathematical properties of the branching system influence a wide range of important phenomena from blood velocity to ultrasound backscatter. Among the mathematical descriptors of branching networks, the spatial autocorrelation function plays an important role in statistical measures of the tissue and of wave propagation through the tissue. However, there are open questions about analytic models of the 3D autocorrelation function for the branching vasculature and few experimental validations for soft vascularized tissue. To address this, high resolution computed tomography scans of a highly vascularized placenta perfused with radiopaque contrast through the umbilical artery were examined. The spatial autocorrelation function was found to be consistent with a power law, which then, in theory, predicts the specific power law behavior of other related functions, including the backscatter of ultrasound.
Collapse
|
46
|
Attenuation of Shear Waves in Normal and Steatotic Livers. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:895-901. [PMID: 30685077 DOI: 10.1016/j.ultrasmedbio.2018.12.002] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/15/2018] [Revised: 11/29/2018] [Accepted: 12/08/2018] [Indexed: 06/09/2023]
Abstract
Shear wave propagation in the liver has been a robust subject of research, with shear wave speed receiving the most attention. The correlation between increased shear wave speed and increased fibrosis in the liver has been established as a useful diagnostic tool. In comparison, the precise mechanisms of shear wave attenuation, and its relation to diseased states of the liver, are less well-established. This study focused on the hypothesis that steatosis adds a viscous (lossy) component to the liver, which increases shear wave attenuation. Twenty patients' livers were scanned with ultrasound and with induced shear wave propagation, and the resulting displacement profiles were analyzed using recently developed estimators to derive both the speed and attenuation of the shear waves within 6-cm2 regions of interest. The results were compared with pathology scores obtained from liver biopsies taken under ultrasound guidance. Across these cases, increases in shear wave attenuation were linked to increased steatosis score. This preliminary study supports the hypothesis and indicates the possible utility of the measurements for non-invasive and quantitative assessment of steatosis.
Collapse
|
47
|
Real-time H-scan ultrasound imaging using a Verasonics research scanner. ULTRASONICS 2019; 94:28-36. [PMID: 30606648 PMCID: PMC6467760 DOI: 10.1016/j.ultras.2018.12.010] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/11/2018] [Revised: 11/29/2018] [Accepted: 12/19/2018] [Indexed: 05/10/2023]
Abstract
H-scan ultrasound (US) is a new imaging technique that relies on matching a model that describes US image formation to the mathematics of a class of Gaussian-weighted Hermite polynomials (GH). In short, H-scan US (where the 'H' denotes Hermite or hue) is a tissue classification technique that images the relative size of acoustic scatterers. Herein, we detail development of a real-time H-scan US imaging technology that was implemented on a programmable US research scanner (Vantage 256, Verasonics Inc, Kirkland, WA). This custom US imaging system has a dual display for real-time visualization of both the H-scan and B-scan US images. This MATLAB-based (Mathworks Inc, Natick, MA) system includes a graphical user interface (GUI) for controlling the entire US scan sequence including the raw radio frequency (RF) data acquisition parameters, image processing, variable control of a parallel set of convolution filters used to derive the H-scan US signal, and data (cine loop) save. The system-level structure used for software-based image reconstruction and display is detailed. Imaging studies were conducted using a series of homogeneous and heterogeneous tissue-mimicking phantom materials embedded with monodisperse spherical US scatterers of size 15-40 µm in diameter. Relative to H-scan US image measurements from a phantom with 15 µm-sized scatterers, data from phantoms with the 30 and 40 µm-sized scatterers exhibited mean intensity increases of 5.2% and 11.6%, respectively. Overall, real-time H-scan US imaging is a promising approach for visualizing the relative size and distribution of acoustic scattering objects.
Collapse
|
48
|
Shear wave propagation in viscoelastic media: validation of an approximate forward model. Phys Med Biol 2019; 64:025008. [PMID: 30524099 DOI: 10.1088/1361-6560/aaf59a] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Many approaches to elastography incorporate shear waves; in some systems these are produced by acoustic radiation force (ARF) push pulses. Understanding the shape and decay of propagating shear waves in lossy tissues is key to obtaining accurate estimates of tissue properties, and so analytical models have been proposed. In this paper, we reconsider a previous analytical model with the goal of obtaining a computationally straightforward and efficient equation for the propagation of shear waves from a focal push pulse. Next, this model is compared with an experimental optical coherence tomography (OCT) system and with finite element models, in two viscoelastic materials that mimic tissue. We find that the three different cases-analytical model, finite element model, and experimental results-demonstrate reasonable agreement within the subtle differences present in their respective conditions. These results support the use of an efficient form of the Hankel transform for both lossless (elastic) and lossy (viscoelastic) media, and for both short (impulsive) and longer (extended) push pulses that can model a range of experimental conditions.
Collapse
|
49
|
Abstract
Across the varieties of waves that have been studied in physics, it is well established that group velocities can be significantly greater than or less than phase velocities measured within comparable frequency bands, depending on the particular mechanisms involved. The distinction between group and phase velocities is important in elastography, because diagnoses are made based on shear wave speed estimations from a variety of techniques. We review the general definitions of group and phase velocity and examine their specific relations within an important general class of rheological models. For the class of tissues and materials exhibiting power law dispersion, group velocity is significantly greater than phase velocity, and simple expressions are shown to interrelate the commonly measured parameters. Examples are given from phantoms and tissues.
Collapse
|
50
|
The nonlinear ultrasound needle pulse. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2018; 144:861. [PMID: 30180703 DOI: 10.1121/1.5050519] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/08/2018] [Accepted: 07/26/2018] [Indexed: 06/08/2023]
Abstract
Recent work has established an analytical formulation of broadband fields which extend in the axial direction and converge to a narrow concentrated line. Those unique (needle) fields have their origins in an angular spectrum configuration in which the forward propagating wavenumber of the field ( kz ) is constant across any z plane for all of the propagated frequencies. A 3 MHz-based, finite amplitude distorted simulation of such a field is considered here in a water path scenario relevant to medical imaging. That nonlinear simulation had its focal features compared to those of a comparable Gaussian beam. The results suggest that the unique convergence of the needle pulse to a narrow but extended axial line in linear propagation is also inherited by higher harmonics in nonlinear propagation. Furthermore, the linear needle field's relatively short duration focal pulses, and the asymptotic declines of its radial profiles, also hold for the associated higher harmonics. Comparisons with the Gaussian field highlight some unique and potentially productive features of needle fields.
Collapse
|