1
|
Balloon pulmonary angioplasty in the current era of CTEPH treatment: How did we get here? Pulm Circ 2023; 13:e12312. [PMID: 38027455 PMCID: PMC10661326 DOI: 10.1002/pul2.12312] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/07/2023] [Revised: 11/06/2023] [Accepted: 11/11/2023] [Indexed: 12/01/2023] Open
Abstract
Chronic thromboembolic pulmonary hypertension (CTEPH) is caused by persistent organized thromboembolic obstruction of the pulmonary arteries from incompletely resolved pulmonary embolism. The treatment of choice is pulmonary thromboendarterectomy (PTE) surgery and all patients should be evaluated for operability candidacy. Despite advancements in PTE technique allowing more segmental-subsegmental surgeries, up to a third of patients with CTEPH may still be considered inoperable. Over the past decade, there have been increasing treatment options for these inoperable CTEPH patients. Balloon pulmonary angioplasty (BPA) is a percutaneous-based interventional treatment option for select CTEPH cases. Early BPA experiences were plagued by high complication rates, but further refinements in technique and equipment pioneered by Japan led to the worldwide spread and adoption of BPA. Multiple centers have shown that patients experience significant improvements in hemodynamics, quality of life, exercise capacity, and survival with BPA treatment. There remain many questions on best practices, but BPA has evolved into a pivotal cornerstone of CTEPH treatment.
Collapse
|
2
|
Coronary Artery and Microvascular Physiology in Heart Transplant Recipients from Hepatitis C Viremic Donors. J Heart Lung Transplant 2023. [DOI: 10.1016/j.healun.2023.02.868] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/05/2023] Open
|
3
|
Time to Standardize Definitions for the Success and Complications of Balloon Pulmonary Angioplasty: A Quality Imperative. JACC Cardiovasc Interv 2023; 16:984-985. [PMID: 36964098 DOI: 10.1016/j.jcin.2023.02.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Accepted: 02/14/2023] [Indexed: 03/26/2023]
|
4
|
CRT-100.12 Risk of Bleeding Among Cangrelor-Treated Patients Administered Upstream P2Y12 Inhibitor Therapy. JACC Cardiovasc Interv 2023. [DOI: 10.1016/j.jcin.2023.01.061] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/22/2023]
|
5
|
Percutaneous Interventional Therapy for Chronic Thromboembolic Pulmonary Hypertension. STRUCTURAL HEART 2022. [DOI: 10.1016/j.shj.2022.100115] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
6
|
Hot topics in interventional cardiology: Proceedings from the society for cardiovascular angiography and interventions (SCAI) 2021 think tank. Catheter Cardiovasc Interv 2021; 98:904-913. [PMID: 34398509 DOI: 10.1002/ccd.29898] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Accepted: 07/28/2021] [Indexed: 01/07/2023]
Abstract
The Society for Cardiovascular Angiography and Interventions (SCAI) Think Tank is a collaborative venture that brings together interventional cardiologists, administrative partners, and select members of the cardiovascular industry community annually for high-level field-wide discussions. The 2021 Think Tank was organized into four parallel sessions reflective of the field of interventional cardiology: (a) coronary intervention, (b) endovascular medicine, (c) structural heart disease, and (d) congenital heart disease. Each session was moderated by a senior content expert and co-moderated by a member of SCAI's Emerging Leader Mentorship program. This document presents the proceedings to the wider cardiovascular community in order to enhance participation in this discussion, create additional dialog from a broader base, and thereby aid SCAI, the industry community and external stakeholders in developing specific action items to move these areas forward.
Collapse
|
7
|
MUSiC: a model-unspecific search for new physics in proton-proton collisions at s = 13 TeV. THE EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS 2021; 81:629. [PMID: 34727144 PMCID: PMC8550789 DOI: 10.1140/epjc/s10052-021-09236-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/06/2020] [Accepted: 05/13/2021] [Indexed: 06/13/2023]
Abstract
Results of the Model Unspecific Search in CMS (MUSiC), using proton-proton collision data recorded at the LHC at a centre-of-mass energy of 13 TeV , corresponding to an integrated luminosity of 35.9 fb - 1 , are presented. The MUSiC analysis searches for anomalies that could be signatures of physics beyond the standard model. The analysis is based on the comparison of observed data with the standard model prediction, as determined from simulation, in several hundred final states and multiple kinematic distributions. Events containing at least one electron or muon are classified based on their final state topology, and an automated search algorithm surveys the observed data for deviations from the prediction. The sensitivity of the search is validated using multiple methods. No significant deviations from the predictions have been observed. For a wide range of final state topologies, agreement is found between the data and the standard model simulation. This analysis complements dedicated search analyses by significantly expanding the range of final states covered using a model independent approach with the largest data set to date to probe phase space regions beyond the reach of previous general searches.
Collapse
Grants
- Austrian Federal Ministry of Education, Science and Research
- Austrian Science Fund
- Belgian Fonds de la Recherche Scientifique
- Belgian Fonds voor Wetenschappelijk Onderzoek
- CNPq
- CAPES
- FAPERJ
- FAPERGS
- FAPESP
- Bulgarian Ministry of Education and Science
- CERN
- Chinese Academy of Sciences
- Ministry of Science and Technology
- Chinese National Natural Science Foundation of China
- Colombian Funding Agency (COLCIENCIAS)
- Croatian Ministry of Science, Education and Sport
- Croatian Science Foundation
- Research and Innovation Foundation
- SENESCYT
- Ministry of Education and Research
- Estonian Research Council via PRG780, PRG803, and PRG445
- European Regional Development Fund
- Academy of Finland
- Finnish Ministry of Education and Culture
- Helsinki Institute of Physics
- Institut National de Physique Nucléaire et de Physique des Particules
- Centre National de la Recherche Scientifique
- Commissariat à l’Énergie Atomique et aux Énergies Alternatives
- Bundesministerium für Bildung und Forschung
- Deutsche Forschungsgemeinschaft
- Helmholtz-Gemeinschaft Deutscher Forschungszentren
- General Secretariat for Research and Technology
- National Research, Development and Innovation Fund
- Department of Atomic Energy
- Department of Science and Technology
- Institute for Research in Fundamental Studies
- Science Foundation
- Istituto Nazionale di Fisica Nucleare
- Korean Ministry of Education, Science and Technology
- National Research Foundation of Korea (NRF)
- MES
- Lithuanian Academy of Sciences
- Ministry of Education
- University of Malaya
- BUAP
- CINVESTAV
- CONACYT
- LNS
- SEP
- UASLP
- MOS
- Ministry of Business, Innovation and Employment
- Pakistan Atomic Energy Commission
- Ministry of Science and Higher Education
- National Science Centre
- Fundação para a Ciência e a Tecnologia
- JINR, Dubna
- Ministry of Education and Science of the Russian Federation
- Federal Agency of Atomic Energy of the Russian Federation
- Russian Academy of Sciences
- Russian Foundation for Basic Research
- National Research Center “Kurchatov Institute”
- Ministry of Education, Science and Technological Development of Serbia
- Secretaría de Estado de Investigación, Desarrollo e Innovación
- Programa Consolider-Ingenio 2010
- Plan de Ciencia, Tecnología e Innovación 2017-2020 del Principado de Asturias, research project IDI-2018-000174
- Fondo Europeo de Desarrollo Regional, Spain
- MOSTR
- ETH Board
- ETH Zurich
- PSI
- SNF
- UniZH
- Canton Zurich
- SER
- Thailand Center of Excellence in Physics
- Institute for the Promotion of Teaching Science and Technology of Thailand
- Special Task Force for Activating Research
- National Science and Technology Development Agency of Thailand
- Scientific and Technical Research Council of Turkey
- Turkish Atomic Energy Authority
- National Academy of Sciences of Ukraine
- Science and Technology Facilities Council
- US Department of Energy
- US National Science Foundation
- Marie-Curie programme
- European Research Council and EPLANET (European Union)
- Horizon 2020 Grant, contract Nos. 675440, 724704, 752730, and 765710 (European Union)
- Leventis Foundation
- Alfred P. Sloan Foundation
- Alexander von Humboldt Foundation
- Belgian Federal Science Policy Office
- Fonds pour la Formation à la Recherche dans l’Industrie et dans l’Agriculture (FRIA-Belgium)
- Agentschap voor Innovatie door Wetenschap en Technologie (IWT-Belgium)
- Belgian Fonds de la Recherche Scientifique, “Excellence of Science - EOS” - be.h project n. 30820817
- Belgian Fonds voor Wetenschappelijk Onderzoek, “Excellence of Science - EOS” - be.h project n. 30820817
- Beijing Municipal Science & Technology Commission, No. Z191100007219010
- Ministry of Education, Youth and Sports (MEYS) of the Czech Republic
- Deutsche Forschungsgemeinschaft (DFG) under Germany’s Excellence Strategy - EXC 2121 “Quantum Universe” – 390833306
- Lendúlet (“Momentum”) Programme and the János Bolyai Research Scholarship of the Hungarian Academy of Sciences
- New National Excellence Program ÚNKP, the NKFIA research grants 123842, 123959, 124845, 124850, 125105, 128713, 128786, and 129058
- Council of Scientific and Industrial Research, India
- HOMING PLUS programme of Foundation for Polish Science, cofinanced from European Union, Regional Development Fund
- National Science Center, Opus 2014/15/B/ST2/03998 and 2015/19/B/ST2/02861
- National Priorities Research Program by Qatar National Research Fund
- Ministry of Science and Higher Education, project no. 0723-2020-0041
- Tomsk Polytechnic University Competitiveness Enhancement Program
- Programa Estatal de Fomento de la Investigación Científica y Técnica de Excelencia María de Maeztu, grant MDM-2015-0509
- Programa Severo Ochoa del Principado de Asturias
- Thalis and Aristeia programmes cofinanced by EU-ESF and the Greek NSRF
- Rachadapisek Sompot Fund for Postdoctoral Fellowship, Chulalongkorn University (Thailand)
- CUAASC
- Kavli Foundation
- Nvidia Corporation
- Welch Foundation, contract C-1845
- Weston Havens Foundation
Collapse
|
8
|
Advances in balloon pulmonary angioplasty for chronic thromboembolic pulmonary hypertension. Pulm Circ 2021; 11:20458940211007385. [PMID: 34104421 PMCID: PMC8150503 DOI: 10.1177/20458940211007385] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Accepted: 03/14/2021] [Indexed: 11/17/2022] Open
Abstract
Balloon pulmonary angioplasty (BPA) is an emerging treatment option for patients with chronic thromboembolic pulmonary hypertension (CTEPH) who have inoperable, segmental/subsegmental disease, or residual disease after pulmonary endarterectomy. In the past decade, advances in the techniques for BPA have led to better clinical outcomes with improvements in hemodynamics, pulmonary perfusion, exercise tolerance, functional capacity, and quality of life. We present the experience with BPA at our university, the largest CTEPH center in the world, followed by reviewing the published data regarding the efficacy and safety of BPA in patients with CTEPH. There is increasing evidence to support that the initial hemodynamic improvement is sustained for ≥3 years after the procedure. Although infrequent, complications observed with BPA are associated with pulmonary vascular injury or rarely reperfusion pulmonary edema. As the technique for percutaneous pulmonary artery revascularization has improved, the procedural risk and complications have continued to decrease. This promising technique continues to develop, and future research is required to demonstrate the long-term benefits of BPA, standardize the technique, and define a uniform institutional infrastructure for providing BPA as a part of the treatment of CTEPH.
Collapse
|
9
|
A case report of cardiogenic shock from takotsubo cardiomyopathy with left ventricular outflow tract obstruction: fundamental lessons in cardiac pathophysiology. EUROPEAN HEART JOURNAL-CASE REPORTS 2021; 5:ytab127. [PMID: 34124552 PMCID: PMC8188875 DOI: 10.1093/ehjcr/ytab127] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/15/2020] [Revised: 12/11/2020] [Accepted: 03/16/2021] [Indexed: 01/23/2023]
Abstract
Background A subset of patients with takotsubo cardiomyopathy will develop significant dynamic left ventricular outflow tract (LVOT) obstruction leading to cardiogenic shock. However, traditional therapies for cardiogenic shock that focus on increased inotropy and afterload reduction can be detrimental in this situation. Case summary We describe a 71-year-old woman who presented to the emergency department with typical, substernal chest pain found to be hypotensive with ST-elevations in the lateral leads. Coronary angiography showed no significant coronary artery disease, but a left ventriculogram demonstrated takotsubo cardiomyopathy. Right heart catheterization revealed cardiogenic shock and elevated filling pressures. Haemodynamics and symptoms worsened with the initiation of dopamine and placement of intra-aortic balloon pump but improved with the initiation of phenylephrine. Follow-up echocardiogram demonstrated dynamic LVOT obstruction with concomitant severe mitral regurgitation (MR). The patient recovered in the intensive care unit for 5 days after successful weaning of phenylephrine and initiation of low-dose beta-blocker. Repeat echocardiogram 3 weeks later showed complete resolution of apical akinesis, LVOT obstruction, and MR. Discussion Elucidating whether dynamic LVOT obstruction is contributing to cardiogenic shock physiology is paramount since the management radically differs depending on the presence or absence of obstruction. Corrective therapy focuses on reducing the LVOT gradient and includes fluid administration to improve preload, beta-blocker therapy to increase diastolic filling time, and vasopressors to raise afterload.
Collapse
|
10
|
Development and validation of HERWIG 7 tunes from CMS underlying-event measurements. THE EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS 2021; 81:312. [PMID: 34727148 PMCID: PMC8550252 DOI: 10.1140/epjc/s10052-021-08949-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/06/2020] [Accepted: 02/03/2021] [Indexed: 06/13/2023]
Abstract
This paper presents new sets of parameters ("tunes") for the underlying-event model of the H E R W I G 7 event generator. These parameters control the description of multiple-parton interactions (MPI) and colour reconnection in H E R W I G 7 , and are obtained from a fit to minimum-bias data collected by the CMS experiment at s = 0.9 , 7, and 13 Te . The tunes are based on the NNPDF 3.1 next-to-next-to-leading-order parton distribution function (PDF) set for the parton shower, and either a leading-order or next-to-next-to-leading-order PDF set for the simulation of MPI and the beam remnants. Predictions utilizing the tunes are produced for event shape observables in electron-positron collisions, and for minimum-bias, inclusive jet, top quark pair, and Z and W boson events in proton-proton collisions, and are compared with data. Each of the new tunes describes the data at a reasonable level, and the tunes using a leading-order PDF for the simulation of MPI provide the best description of the data.
Collapse
Grants
- Austrian Federal Ministry of Education, Science, and Research
- Austrian Science Fund
- Belgian Fonds de la Recherche Scientifique
- Belgian Fonds voor Wetenschappelijk Onderzoek
- CNPq
- CAPES
- FAPERJ
- FAPERGS
- FAPESP
- Bulgarian Ministry of Education and Science
- CERN
- Chinese Academy of Sciences
- Ministry of Science and Technology
- Chinese National Natural Science Foundation of China
- Colombian Funding Agency (COLCIENCIAS)
- Croatian Ministry of Science, Education and Sport
- Croatian Science Foundation
- Research and Innovation Foundation
- SENESCYT
- Ministry of Education and Research
- Estonian Research Council via PRG780, PRG803, and PRG445
- European Regional Development Fund
- Academy of Finland
- Finnish Ministry of Education and Culture
- Helsinki Institute of Physics
- Institut National de Physique Nucléaire et de Physique des Particules
- Centre National de la Recherche Scientifique
- Commissariat à l’Énergie Atomique et aux Énergies Alternatives
- Bundesministerium für Bildung und Forschung
- Deutsche Forschungsgemeinschaft
- Helmholtz-Gemeinschaft Deutscher Forschungszentren
- General Secretariat for Research and Technology
- National Research, Development and Innovation Fund
- Department of Atomic Energy
- Department of Science and Technology
- Institute for Research in Fundamental Studies
- Science Foundation
- Istituto Nazionale di Fisica Nucleare
- Korean Ministry of Education, Science and Technology
- National Research Foundation of Korea (NRF)
- MES
- Lithuanian Academy of Sciences
- Ministry of Education
- University of Malaya
- BUAP
- CINVESTAV
- CONACYT
- LNS
- SEP
- UASLP
- MOS
- Ministry of Business, Innovation and Employment
- Pakistan Atomic Energy Commission
- Ministry of Science and Higher Education
- National Science Centre
- Fundação para a Ciência e a Tecnologia
- JINR, Dubna
- Ministry of Education and Science of the Russian Federation
- Federal Agency of Atomic Energy of the Russian Federation
- Russian Academy of Sciences
- Russian Foundation for Basic Research
- National Research Center “Kurchatov Institute"
- Ministry of Education, Science and Technological Development of Serbia
- Secretaría de Estado de Investigación, Desarrollo e Innovación
- Programa Consolider-Ingenio 2010
- Plan de Ciencia, Tecnología e Innovación 2017-2020 del Principado de Asturias, research project IDI-2018-000174
- Fondo Europeo de Desarrollo Regional, Spain
- MOSTR
- ETH Board
- ETH Zurich
- PSI
- SNF
- UniZH
- Canton Zurich
- SER
- Ministry of Science and Technology
- Thailand Center of Excellence in Physics
- Institute for the Promotion of Teaching Science and Technology of Thailand
- Special Task Force for Activating Research
- National Science and Technology Development Agency of Thailand
- Scientific and Technical Research Council of Turkey
- Turkish Atomic Energy Authority
- National Academy of Sciences of Ukraine
- Science and Technology Facilities Council
- US Department of Energy
- US National Science Foundation
- Marie-Curie programme
- European Research Council and EPLANET (European Union)
- Horizon 2020 Grant, contract Nos. 675440,724704, 752730, and 765710 (European Union)
- Leventis Foundation
- Alfred P. Sloan Foundation
- Alexander von Humboldt Foundation
- Belgian Federal Science Policy Office
- Fonds pour la Formation à la Recherche dans l’Industrie et dans l’Agriculture (FRIA-Belgium)
- Agentschap voor Innovatie door Wetenschap en Technologie (IWT-Belgium)
- Belgian Fonds de la Recherche Scientifique, "Excellence of Science - EOS" - be.h project n. 30820817
- Belgian Fonds voor Wetenschappelijk Onderzoek, "Excellence of Science - EOS" - be.h project n. 30820817
- Beijing Municipal Science & Technology Commission, No. Z191100007219010
- Ministry of Education, Youth and Sports (MEYS) of the Czech Republic
- Deutsche Forschungsgemeinschaft (DFG) under Germany’s Excellence Strategy - EXC 2121 “Quantum Universe” – 390833306
- Lendúlet (“Momentum”) Programme and the János Bolyai Research Scholarship of the Hungarian Academy of Sciences
- New National Excellence Program ÚNKP, the NKFIA research Grants 123842, 123959, 124845, 124850and, 125105, 128713, 128786, and 129058
- Council of Scientific and Industrial Research, India
- HOMING PLUS programme of Foundation for Polish Science, cofinanced from European Union, Regional Development Fund
- National Science Center, contracts Harmonia 2014/14/M/ST2/00428, Opus 2014/13/B/ST2/02543, 2014/15/B/ST2/03998, and 2015/19/B/ST2/02861, Sonata-bis 2012/07/E/ST2/01406
- National Priorities Research Program by Qatar National Research Fund
- Ministry of Science and Higher Education, project no. 02.a03.21.0005
- Tomsk Polytechnic University Competitiveness Enhancement Program
- Programa Estatal de Fomento de la Investigación Científica y Técnica de Excelencia María de Maeztu, Grant MDM-2015-0509
- Programa Severo Ochoa del Principado de Asturias
- Thalis and Aristeia programmes cofinanced by EU-ESF and the Greek NSRF
- Rachadapisek Sompot Fund for Postdoctoral Fellowship, Chulalongkorn University (Thailand)
- CUAASC
- Kavli Foundation
- Nvidia Corporation
- Welch Foundation, contract C-1845
- Weston Havens Foundation
Collapse
|
11
|
Medicine in motion: Opportunities, challenges and data analytics-based solutions for traditional medicine integration into western medical practice. JOURNAL OF ETHNOPHARMACOLOGY 2021; 267:113477. [PMID: 33098971 PMCID: PMC7577282 DOI: 10.1016/j.jep.2020.113477] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Revised: 09/23/2020] [Accepted: 10/13/2020] [Indexed: 05/03/2023]
Abstract
ETHNOPHARMACOLOGICAL RELEVANCE Traditional pharmacopeias have been developed by multiple cultures and evaluated for efficacy and safety through both historical/empirical iteration and more recently through controlled studies using Western scientific paradigms and an increasing emphasis on data science methodologies for network pharmacology. Traditional medicines represent likely sources of relatively inexpensive drugs for symptomatic management as well as potential libraries of new therapeutic approaches. Leveraging this potential requires hard evidence for efficacy that separates science from pseudoscience. MATERIALS AND METHODS We performed a review of non-Western medical systems and developed case studies that illustrate the epistemological and practical translative barriers that hamper their transition to integration with Western approaches. We developed a new data analytics approach, in silico convergence analysis, to deconvolve modes of action, and potentially predict desirable components of TM-derived formulations based on computational consensus analysis across cultures and medical systems. RESULTS Abstraction, simplification and altered dose and delivery modalities were identified as factors that influence actual and perceived efficacy once a medicine is moved from a non-Western to Western setting. Case studies on these factors highlighted issues with translation between non-Western and Western epistemologies, including those where epistemological and medicinal systems drive markets that can be epicenters for zoonoses such as the novel Coronavirus. The proposed novel data science approach demonstrated the ability to identify and predict desirable medicinal components for a test indication, pain. CONCLUSIONS Relegation of traditional therapies to the relatively unregulated nutraceutical industry may lead healthcare providers and patients to underestimate the therapeutic potential of these medicines. We suggest three areas of emphasis for this field: First, vertical integration and embedding of traditional medicines into healthcare systems would subject them to appropriate regulation and evidence-based practice, as viable integrative implementation mode. Second, we offer a new Bradford-Hill-like framework for setting research priorities and evaluating efficacy, with the goal of rescuing potentially valuable therapies from the nutraceutical market and discrediting those that are pseudoscience. Third, data analytics pipelines offer new capacity to generate new types of TMS-inspired medicines that are rationally-designed based on integrated knowledge across cultures, and also provide an evaluative framework against which to test claims of fidelity and efficacy to TMS made for nutraceuticals.
Collapse
|
12
|
Resource Utilization During Elective Robotic-Assisted Percutaneous Coronary Intervention. THE JOURNAL OF INVASIVE CARDIOLOGY 2020; 32:E321-E325. [PMID: 32829309] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
OBJECTIVE Robotic percutaneous coronary intervention (R-PCI) results in comparable outcomes to manual PCI in the treatment of obstructive coronary artery disease (CAD). The objective of this study is to evaluate the cost and resource utilization of R-PCI compared with manual PCI. METHODS Consecutive patients with CAD undergoing elective R-PCI or manual PCI over an 18-month period by a single operator were included. Procedure-related costs and resource utilization were analyzed and propensity adjusted to account for differences in baseline demographic and lesion characteristics. RESULTS A total of 164 patients (mean age, 68.9 ± 10.8 years; 81% men) underwent R-PCI (n = 56) or manual PCI (n = 108). The R-PCI group demonstrated higher Syntax scores (17.8 ± 12.9% vs 11.8 ± 7.7%; P<.01) and a greater proportion of type B2/C lesions (89.3% vs 69.4%; P<.01). R-PCI was associated with higher unadjusted costs of total hospitalization ($8219.90 ± 336.60 vs $7268.50 ± 220.10; P=.02) and direct supplies ($4711.10 ± 239.90 vs $3809.40 ± 166.80; P<.01). Following propensity-matched analysis, R-PCI was associated with higher direct supply costs alone, without a significant difference in total hospitalization or catheterization laboratory cost. Furthermore, R-PCI demonstrated similar fluoroscopy time, procedural time, and total number of stents, but with a lower volume of contrast (182.7 ± 8.9 mL vs 206.8 ± 9.0 mL; P=.04). CONCLUSIONS Costs and resources associated with R-PCI are comparable with manual PCI, with an expected increase in direct supply costs attributed to single-use robotic components.
Collapse
|
13
|
Evidence for Top Quark Production in Nucleus-Nucleus Collisions. PHYSICAL REVIEW LETTERS 2020; 125:222001. [PMID: 33315428 DOI: 10.1103/physrevlett.125.222001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/28/2020] [Accepted: 10/07/2020] [Indexed: 06/12/2023]
Abstract
Ultrarelativistic heavy ion collisions recreate in the laboratory the thermodynamical conditions prevailing in the early universe up to 10^{-6} sec, thereby allowing the study of the quark-gluon plasma (QGP), a state of quantum chromodynamics (QCD) matter with deconfined partons. The top quark, the heaviest elementary particle known, is accessible in nucleus-nucleus collisions at the CERN LHC, and constitutes a novel probe of the QGP. Here, we report the first evidence for the production of top quarks in nucleus-nucleus collisions, using lead-lead collision data at a nucleon-nucleon center-of-mass energy of 5.02 TeV recorded by the CMS experiment. Two methods are used to measure the cross section for top quark pair production (σ_{tt[over ¯]}) via the selection of charged leptons (electrons or muons) and bottom quarks. One method relies on the leptonic information alone, and the second one exploits, in addition, the presence of bottom quarks. The measured cross sections, σ_{tt[over ¯]}=2.54_{-0.74}^{+0.84} and 2.03_{-0.64}^{+0.71} μb, respectively, are compatible with expectations from scaled proton-proton data and QCD predictions.
Collapse
|
14
|
Observation of the B_{s}^{0}→X(3872)ϕ Decay. PHYSICAL REVIEW LETTERS 2020; 125:152001. [PMID: 33095627 DOI: 10.1103/physrevlett.125.152001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2020] [Revised: 06/22/2020] [Accepted: 08/27/2020] [Indexed: 06/11/2023]
Abstract
Using a data sample of proton-proton collisions at sqrt[s]=13 TeV, corresponding to an integrated luminosity of 140 fb^{-1} collected by the CMS experiment in 2016-2018, the B_{s}^{0}→X(3872)ϕ decay is observed. Decays into J/ψπ^{+}π^{-} and K^{+}K^{-} are used to reconstruct, respectively, the X(3872) and ϕ. The ratio of the product of branching fractions B[B_{s}^{0}→X(3872)ϕ]B[X(3872)→J/ψπ^{+}π^{-}] to the product B[B_{s}^{0}→ψ(2S)ϕ]B[ψ(2S)→J/ψπ^{+}π^{-}] is measured to be [2.21±0.29(stat)±0.17(syst)]%. The ratio B[B_{s}^{0}→X(3872)ϕ]/B[B^{0}→X(3872)K^{0}] is found to be consistent with one, while the ratio B[B_{s}^{0}→X(3872)ϕ]/B[B^{+}→X(3872)K^{+}] is two times smaller. This suggests a difference in the production dynamics of the X(3872) in B^{0} and B_{s}^{0} meson decays compared to B^{+}. The reported observation may shed new light on the nature of the X(3872) particle.
Collapse
|
15
|
Observation of the Production of Three Massive Gauge Bosons at sqrt[s]=13 TeV. PHYSICAL REVIEW LETTERS 2020; 125:151802. [PMID: 33095594 DOI: 10.1103/physrevlett.125.151802] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2020] [Accepted: 08/24/2020] [Indexed: 06/11/2023]
Abstract
The first observation is reported of the combined production of three massive gauge bosons (VVV with V=W, Z) in proton-proton collisions at a center-of-mass energy of 13 TeV. The analysis is based on a data sample recorded by the CMS experiment at the CERN LHC corresponding to an integrated luminosity of 137 fb^{-1}. The searches for individual WWW, WWZ, WZZ, and ZZZ production are performed in final states with three, four, five, and six leptons (electrons or muons), or with two same-sign leptons plus one or two jets. The observed (expected) significance of the combined VVV production signal is 5.7 (5.9) standard deviations and the corresponding measured cross section relative to the standard model prediction is 1.02_{-0.23}^{+0.26}. The significances of the individual WWW and WWZ production are 3.3 and 3.4 standard deviations, respectively. Measured production cross sections for the individual triboson processes are also reported.
Collapse
|
16
|
Robotic Peripheral Vascular Intervention With Drug-Coated Balloons is Feasible and Reduces Operator Radiation Exposure: Results of the Robotic-Assisted Peripheral Intervention for Peripheral Artery Disease (RAPID) Study II. THE JOURNAL OF INVASIVE CARDIOLOGY 2020; 32:380-384. [PMID: 32999092] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
BACKGROUND A robotic-assisted platform (CorPath System; Corindus Vascular Robotics) is feasible for peripheral vascular intervention (PVI) for the treatment of femoropopliteal lesions. OBJECTIVES This study was designed to determine the feasibility and safety of robotic PVI for treating femoropopliteal lesions with drug-coated balloon (DCB), and to evaluate the effect of robotic PVI on operator radiation exposure during robotic PVI. METHODS This prospective, single-arm trial enrolled patients with symptomatic peripheral arterial disease affecting the femoropopliteal artery. The primary outcome measure was clinical success, defined as <50% residual stenosis and the absence of periprocedural device-related serious adverse events. Operator radiation exposure was compared between the robotic cockpit vs the tableside. RESULTS This study enrolled 20 patients (age, 65.5 ± 9.9 years; 60% men), with the majority (75%) Rutherford category 3-4. A total of 24 lesions (lesion length, 49.8 ± 37.5 mm) were treated with DCB and 91.7% were located in the superficial femoral artery. Clinical success was 100% and provisional stenting was required in 1 lesion. Fluoroscopy time was 7.3 ± 3.3 minutes and operator radiation exposure was 1.9 ± 2.9 μSv, which was reduced by 96.9 ± 5.0% when compared with the table-side (control) dosimeter (P<.001). There were no adverse events associated with the use of the robotic system. CONCLUSIONS These data demonstrate the safety and feasibility of using a robotic-assisted platform for treating femoropopliteal lesions with rapid-exchange interventional devices, and show 96.9% reduction in radiation exposure for the primary operator.
Collapse
|
17
|
Cardiac procedural deferral during the coronavirus (
COVID
‐19) pandemic. Catheter Cardiovasc Interv 2020; 96:1080-1086. [DOI: 10.1002/ccd.29262] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/27/2020] [Accepted: 08/31/2020] [Indexed: 12/18/2022]
|
18
|
Measurements of tt[over ¯]H Production and the CP Structure of the Yukawa Interaction between the Higgs Boson and Top Quark in the Diphoton Decay Channel. PHYSICAL REVIEW LETTERS 2020; 125:061801. [PMID: 32845700 DOI: 10.1103/physrevlett.125.061801] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/24/2020] [Accepted: 06/19/2020] [Indexed: 06/11/2023]
Abstract
The first observation of the tt[over ¯]H process in a single Higgs boson decay channel with the full reconstruction of the final state (H→γγ) is presented, with a significance of 6.6 standard deviations (σ). The CP structure of Higgs boson couplings to fermions is measured, resulting in an exclusion of the pure CP-odd structure of the top Yukawa coupling at 3.2σ. The measurements are based on a sample of proton-proton collisions at a center-of-mass energy sqrt[s]=13 TeV collected by the CMS detector at the LHC, corresponding to an integrated luminosity of 137 fb^{-1}. The cross section times branching fraction of the tt[over ¯]H process is measured to be σ_{tt[over ¯]H}B_{γγ}=1.56_{-0.32}^{+0.34} fb, which is compatible with the standard model prediction of 1.13_{-0.11}^{+0.08} fb. The fractional contribution of the CP-odd component is measured to be f_{CP}^{Htt}=0.00±0.33.
Collapse
|
19
|
SCAI
position statement on the performance of percutaneous coronary intervention in ambulatory surgical centers. Catheter Cardiovasc Interv 2020; 96:862-870. [DOI: 10.1002/ccd.28991] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Accepted: 05/08/2020] [Indexed: 11/10/2022]
|
20
|
Planned Robotic Chronic Total Occlusion Percutaneous Coronary Intervention: Feasibility Report. THE JOURNAL OF INVASIVE CARDIOLOGY 2020; 32:201-205. [PMID: 32330119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
BACKGROUND Complex robotic percutaneous coronary intervention (R-PCI) is technically possible and leads to clinically comparable outcomes compared with the manual approach. However, there are limited data on the feasibility of chronic total occlusion (CTO) revascularization via the R-PCI approach. METHODS Ten consecutive patients undergoing R-PCI for a coronary CTO at a single tertiary academic center were analyzed. The PRECISION, PRECISION GRX, and PROGRESS CTO registries were utilized for data collection with regard to procedural/clinical details and results. RESULTS Technical success, defined as successful CTO revascularization with full or partial robotic support, occurred in 7 of 10 patients. There were no periprocedural major adverse cardiac events. Average J-CTO score was 2; all procedures were performed from an antegrade approach. The time from robotic wire manipulation to completion of procedure regardless of method averaged 55.1 minutes; average fluoroscopy time was 29.9 minutes. CONCLUSIONS CTO revascularization via a robotic approach is feasible. Technical success may be best predicted by those patients with low J-CTO scores and lesions amenable to antegrade wire escalation technique. Given the potential benefits to both operators and patients, further research is warranted.
Collapse
|
21
|
Constraints on the χ_{c1} versus χ_{c2} Polarizations in Proton-Proton Collisions at sqrt[s]=8 TeV. PHYSICAL REVIEW LETTERS 2020; 124:162002. [PMID: 32383915 DOI: 10.1103/physrevlett.124.162002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/16/2019] [Revised: 01/25/2020] [Accepted: 03/26/2020] [Indexed: 06/11/2023]
Abstract
The polarizations of promptly produced χ_{c1} and χ_{c2} mesons are studied using data collected by the CMS experiment at the LHC, in proton-proton collisions at sqrt[s]=8 TeV. The χ_{c} states are reconstructed via their radiative decays χ_{c}→J/ψγ, with the photons being measured through conversions to e^{+}e^{-}, which allows the two states to be well resolved. The polarizations are measured in the helicity frame, through the analysis of the χ_{c2} to χ_{c1} yield ratio as a function of the polar or azimuthal angle of the positive muon emitted in the J/ψ→μ^{+}μ^{-} decay, in three bins of J/ψ transverse momentum. While no differences are seen between the two states in terms of azimuthal decay angle distributions, they are observed to have significantly different polar anisotropies. The measurement favors a scenario where at least one of the two states is strongly polarized along the helicity quantization axis, in agreement with nonrelativistic quantum chromodynamics predictions. This is the first measurement of significantly polarized quarkonia produced at high transverse momentum.
Collapse
|
22
|
COST AND RESOURCE UTILIZATION DURING ELECTIVE ROBOTIC ASSISTED PERCUTANEOUS CORONARY INTERVENTION. J Am Coll Cardiol 2020. [DOI: 10.1016/s0735-1097(20)34128-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
23
|
Abstract
Nociceptive Transient Receptor Potential channels such as TRPV1 are targets for treating pain. Both antagonism and agonism of TRP channels can promote analgesia, through inactivation and chronic desensitization. Since plant-derived mixtures of cannabinoids and the Cannabis component myrcene have been suggested as pain therapeutics, we screened terpenes found in Cannabis for activity at TRPV1. We used inducible expression of TRPV1 to examine TRPV1-dependency of terpene-induced calcium flux responses. Terpenes contribute differentially to calcium fluxes via TRPV1 induced by Cannabis-mimetic cannabinoid/terpenoid mixtures. Myrcene dominates the TRPV1-mediated calcium responses seen with terpenoid mixtures. Myrcene-induced calcium influx is inhibited by the TRPV1 inhibitor capsazepine and Myrcene elicits TRPV1 currents in the whole-cell patch-clamp configuration. TRPV1 currents are highly sensitive to internal calcium. When Myrcene currents are evoked, they are distinct from capsaicin responses on the basis of Imax and their lack of shift to a pore-dilated state. Myrcene pre-application and residency at TRPV1 appears to negatively impact subsequent responses to TRPV1 ligands such as Cannabidiol, indicating allosteric modulation and possible competition by Myrcene. Molecular docking studies suggest a non-covalent interaction site for Myrcene in TRPV1 and identifies key residues that form partially overlapping Myrcene and Cannabidiol binding sites. We identify several non-Cannabis plant-derived sources of Myrcene and other compounds targeting nociceptive TRPs using a data mining approach focused on analgesics suggested by non-Western Traditional Medical Systems. These data establish TRPV1 as a target of Myrcene and suggest the therapeutic potential of analgesic formulations containing Myrcene.
Collapse
|
24
|
Chronic Thromboembolic Pulmonary Hypertension: Evolving Therapeutic Approaches for Operable and Inoperable Disease. J Am Coll Cardiol 2019; 71:2468-2486. [PMID: 29793636 DOI: 10.1016/j.jacc.2018.04.009] [Citation(s) in RCA: 104] [Impact Index Per Article: 20.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2017] [Revised: 03/19/2018] [Accepted: 04/03/2018] [Indexed: 12/31/2022]
Abstract
Chronic thromboembolic pulmonary hypertension (CTEPH), a rare consequence of an acute pulmonary embolism, is a disease that is underdiagnosed, and surgical pulmonary thromboendarterectomy (PTE) remains the preferred therapy. However, determination of operability is multifactorial and can be challenging. There is growing excitement for the percutaneous treatment of inoperable CTEPH with data from multiple centers around the world showing the clinical feasibility of balloon pulmonary angioplasty. Riociguat remains the only approved medical therapy for CTEPH patients deemed inoperable or with persistent pulmonary hypertension after PTE. We recommend that expert multidisciplinary CTEPH teams be developed at individual institutions. Additionally, optimal and standardized techniques for balloon pulmonary angioplasty need to be developed along with dedicated interventional equipment and appropriate training standards. In the meantime, the percutaneous revascularization option is appropriate for patients deemed inoperable in combination with targeted medical therapy, or those who have failed to benefit from surgery.
Collapse
|
25
|
Abstract
Chronic thromboembolic pulmonary hypertension (CTEPH) is associated with several risk factors but is most frequently seen as a rare consequence of an acute pulmonary embolism. Surgical pulmonary thromboendarterectomy (PTE) is potentially curative for CTEPH with the best outcomes seen for the treatment of primarily proximal, accessible lobar or segmental disease. For surgically inoperable patients, percutaneous balloon pulmonary angioplasty (BPA) is feasible and has good short- to mid-term efficacy outcomes. This review focuses on the technique and outcomes associated with BPA which has emerged as a new therapeutic option for CTEPH.
Collapse
|
26
|
Optimal Technique for Performing Invasive Pulmonary Angiography for Chronic Thromboembolic Pulmonary Disease. THE JOURNAL OF INVASIVE CARDIOLOGY 2019; 31:E211-E219. [PMID: 31257216] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
High-quality invasive pulmonary angiography is invaluable for the evaluation of chronic pulmonary thromboembolic disease. Optimization of multiple technical factors enables optimal angiography, crucial for identifying both high-grade pulmonary thromboembolic disease warranting surgical resection, and surgically inaccessible disease for interventional and/or targeted medical therapy. Appropriate strategies to address the pitfalls encountered during angiography are highlighted. This manuscript provides detailed guidance in performing hemodynamic assessment and invasive pulmonary angiography for the evaluation of chronic thromboembolic pulmonary disease.
Collapse
|
27
|
Abstract
The occupational hazards for interventional cardiologists include the risk of cataracts, malignancy, and orthopedic injury. Robotic technology is now available with the introduction of platforms for performing percutaneous coronary and peripheral interventions. The original remote navigation system has evolved into the current CorPath robotic system, now approved for robotic-assisted cardiovascular interventions. The system removes the operator from the tableside and has been validated for safety, feasibility, and efficacy in coronary and peripheral vascular disease.
Collapse
|
28
|
Complex robotic compared to manual coronary interventions: 6‐ and 12‐month outcomes. Catheter Cardiovasc Interv 2018; 93:613-617. [DOI: 10.1002/ccd.27867] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/11/2018] [Revised: 06/30/2018] [Accepted: 08/10/2018] [Indexed: 11/06/2022]
|
29
|
Bacterial Contamination of Lead Aprons in a High-Volume Cardiac Catheterization Laboratory and Disinfection Using an Automated Ultraviolet-C Radiation System. THE JOURNAL OF INVASIVE CARDIOLOGY 2018; 30:416-420. [PMID: 30373951] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
OBJECTIVES Quantify and characterize bacterial contamination of lead aprons in a high-volume catheterization laboratory and evaluate the efficacy of decontamination using an ultraviolet-C (UV-C) radiation system. BACKGROUND Bacterial contamination and ineffective disinfection of personal protective equipment in medical centers pose potential health risks to patients and medical staff. The contamination burden of lead aprons and a reliable disinfection strategy are unknown. METHODS Ten routinely used, unsterilized lead aprons from a high-volume catheterization laboratory were studied. Standard and bacteria-resistant outer fabrics were included. Swabbings from four locations on each apron (inner thyroid collar, chest, waist, and bottom border) were obtained at baseline and after a 15-minute decontamination cycle using the UV-C based DCab System (Nosocom Solutions). Colony counts, speciation, and antibiotic resistance were obtained from aerobic and anaerobic cultures. RESULTS Baseline cultures grew ≥1 colony from 25 of 40 samples (62.5%; 310 colonies; 0-100 colonies/sample; 16 organisms), mainly skin and mouth flora without antibiotic resistance. Baseline growth was greatest from the thyroid collar and similar between different fabrics. UV-C reduced subsequent growth (7.8 ± 23.8 colonies overall vs 0.1 ± 0.3 colonies overall; P<.001), with all four isolates considered contaminants of laboratory handling. Colony counts were reduced in thyroid collar, chest, waist, nylon fabric, polyurethane fabric, and alternative bacteria-resistant fabric subgroups (all P<.05). CONCLUSIONS Routinely used lead aprons in a high-volume catheterization laboratory were contaminated by non-pathogenic skin and mouth flora located predominantly on the thyroid collar. Disinfection using an automated UV-C based system is highly effective across different apron surface locations and fabric types.
Collapse
|
30
|
TCT-165 Safety of Balloon Pulmonary Angioplasty for Chronic Thromboembolic Pulmonary Hypertension: Initial Single Center United States Experience. J Am Coll Cardiol 2018. [DOI: 10.1016/j.jacc.2018.08.1276] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
31
|
TCT-442 Robotic Peripheral Vascular Intervention with Drug Coated Balloons is Feasible and Reduces Operator Radiation Exposure: Results of the Robotic-Assisted Peripheral Intervention for Peripheral Artery Disease (RAPID) Study II. J Am Coll Cardiol 2018. [DOI: 10.1016/j.jacc.2018.08.1608] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
32
|
TCT-57 Hemodynamic and Functional Improvement Following Balloon Pulmonary Angioplasty for Chronic Thromboembolic Pulmonary Hypertension: Initial Experience at a High Volume Pulmonary Thromboendarterectomy Center. J Am Coll Cardiol 2018. [DOI: 10.1016/j.jacc.2018.08.1145] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
33
|
Safety and Feasibility of a Novel, Second-Generation Robotic-Assisted System for Percutaneous Coronary Intervention: First-in-Human Report. THE JOURNAL OF INVASIVE CARDIOLOGY 2018; 30:152-156. [PMID: 29335386] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
OBJECTIVES The goal of this study is to evaluate the safety and efficacy of the second-generation robotic-assisted system CorPath GRX (Corindus) for percutaneous coronary intervention (PCI). BACKGROUND The first-generation CorPath 200 robotic-assisted system for PCI is effective, but is limited by the lack of an active robotic guide-catheter control. The CorPath GRX device enables robotic guide-catheter manipulation, in addition to guidewire and balloon/stent delivery. However, there have been no clinical data reported with this device. METHODS Consecutive patients with demonstrated obstructive coronary artery disease (>70% stenosis) and clinical indications for PCI were treated with the CorPath GRX system and enrolled in the study. The two co-primary endpoints were clinical procedural success (final TIMI 3 flow, and <30% residual stenosis without in-hospital major adverse cardiac event) and device technical success (robotic clinical procedural success without the need for unplanned manual assistance/conversion). RESULTS The study enrolled 40 subjects (65.7 ± 11.9 years; 72.5% males; 54 lesions) with a high proportion of American College of Cardiology/American Heart Association type B2/C lesions (77.8%). Clinical procedural success and device technical success rates were 97.5% (n = 39 of 40) and 90.0% (n = 36 of 40), respectively. CONCLUSION The second-generation CorPath GRX system for robotic-assisted PCI is safe and effective, and achieves high rates of clinical and technical success in a cohort of patients with complex coronary disease.
Collapse
|
34
|
A Bleeding Heart: Coronary-Cameral Fistula After Septal Myomectomy. THE JOURNAL OF INVASIVE CARDIOLOGY 2017; 29:E199-E200. [PMID: 29207370] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Coronary-cameral fistulas are relatively rare communications arising within the coronary vasculature entering into one of the four cardiac chambers. This case highlights a striking angiographic example of coronary-cameral fistula occurring after septal myomectomy, a complication occurring somewhat frequently with typical spontaneous resolution.
Collapse
|
35
|
Elevated Baseline Serum Fibrinogen: Effect on 2-Year Major Adverse Cardiovascular Events Following Percutaneous Coronary Intervention. J Am Heart Assoc 2017; 6:JAHA.117.006580. [PMID: 29151032 PMCID: PMC5721757 DOI: 10.1161/jaha.117.006580] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Background Elevated fibrinogen is associated with short‐term major adverse cardiovascular events (MACE) after percutaneous coronary intervention, but the relation with late MACE is unknown. Methods and Results Baseline demographics and 2‐year MACE were recorded among subjects undergoing nonemergent percutaneous coronary intervention. A total of 332 subjects (66.6±19.5 years, 69.9% male, 25.3% acute coronary syndrome) were enrolled. Two‐year MACE (periprocedural myocardial infarction 9.0%, rehospitalization 6.3%, revascularization 12.7%, non–periprocedural myocardial infarction 4.5%, stent thrombosis 0.9%, stroke 1.8%, and death 0.6%) were associated with higher fibrinogen (352.8±123.4 mg/dL versus 301.6±110.8 mg/dL; P<0.001), longer total stent length (40.1±25.3 mm versus 32.1±19.3 mm; P=0.004), acute coronary syndrome indication (38.7% versus 17.8%; P<0.001), number of bare‐metal stents (0.5±1.1 versus 0.2±0.5; P=0.002), and stent diameter ≤2.5 mm (55.8% versus 38.4%, P=0.003). No relation between platelet reactivity and 2‐year MACE was observed. Fibrinogen ≥280 mg/dL (odds ratio [OR] 3.0, confidence interval [CI], 1.6–5.4, P<0.001), total stent length ≥32 mm (OR 2.2, CI, 1.3–3.8, P<0.001), acute coronary syndrome indication (OR 4.1, CI, 2.3–7.5, P<0.001), any bare‐metal stents (OR 3.2, CI, 1.6–6.1, P<0.001), and stent diameter ≤2.5 mm (OR 2.0, CI, 1.2–3.5, P=0.010) were independently associated with 2‐year MACE. Following a landmark analysis excluding periprocedural myocardial infarction, fibrinogen ≥280 mg/dL remained strongly associated with 2‐year MACE (37.0% versus 17.4%, log‐rank P<0.001). Conclusions Elevated baseline fibrinogen level is associated with 2‐year MACE after percutaneous coronary intervention. Acute coronary syndrome indication for percutaneous coronary intervention, total stent length implanted, and use of bare‐metal stents or smaller‐diameter stents are also independently associated with 2‐year MACE, while measures of on‐thienopyridine platelet reactivity are not.
Collapse
|
36
|
Robotically-assisted percutaneous coronary intervention: Reasons for partial manual assistance or manual conversion. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2017; 19:526-531. [PMID: 29221959 DOI: 10.1016/j.carrev.2017.11.003] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2017] [Revised: 11/04/2017] [Accepted: 11/06/2017] [Indexed: 12/22/2022]
Abstract
BACKGROUND Robotically-assisted percutaneous coronary intervention (R-PCI) is feasible for simple coronary lesions. OBJECTIVES To determine the frequency and reasons for partial manual assistance or manual conversion during R-PCI in clinical practice. METHODS The CorPath 200 System (Corindus, Waltham, MA) enables the operator to sit in a radiation-shielded cockpit and remotely control intracoronary devices including guidewires, balloons, and stents. Consecutive R-PCI procedures performed over 18months were analyzed to identify reasons for planned or unplanned manual assistance or manual conversion, and categorized as due to 1) adverse event; 2) technical limitation of the robotic platform; or 3) limited guide catheter/wire support. RESULTS During the study period, 108 R-PCI procedures (68.1±11.0years, 77.8% men, 69.4% elective PCI, 78.3% type B2/C lesions, and 50.3% left anterior descending/left main target lesion segment) were performed. High robotic technical success (91.7%) and clinical procedural success (99.1%) were achieved. Twenty procedures (18.5%) required either planned partial manual assistance (3.7%), unplanned partial manual assistance (7.4%), or manual conversion (7.4%). Among these procedures, manual assistance/conversion was required in 3 procedures for an adverse event (15%), 8 for technical limitation of the robotic platform (40%), and 9 for guide catheter/wire support issues (45%). CONCLUSIONS High clinical success with R-PCI for a complex lesion cohort is possible with only occasional partial manual assistance or manual conversion. The majority of procedures requiring manual assistance/conversion were due to limited guide catheter/wire support or robotic platform limitations, rather than occurrence of adverse events.
Collapse
|
37
|
Abstract
INTRODUCTION The fundamental technique of performing percutaneous cardiovascular (CV) interventions has remained unchanged and requires operators to wear heavy lead aprons to minimize exposure to ionizing radiation. Robotic technology is now being utilized in interventional cardiology partially as a direct result of the increasing appreciation of the long-term occupational hazards of the field. This review was undertaken to report the clinical outcomes of percutaneous robotic coronary and peripheral vascular interventions. Areas covered: A systematic literature review of percutaneous robotic CV interventions was undertaken. The safety and feasibility of percutaneous robotically-assisted CV interventions has been validated in simple to complex coronary disease, and iliofemoral disease. Studies have shown that robotically-assisted PCI significantly reduces operator exposure to harmful ionizing radiation without compromising procedural success or clinical efficacy. In addition to the operator benefits, robotically-assisted intervention has the potential for patient advantages by allowing more accurate lesion length measurement, precise stent placement and lower patient radiation exposure. However, further investigation is required to fully elucidate these potential benefits. Expert commentary: Incremental improvement in robotic technology and telecommunications would enable treatment of an even broader patient population, and potentially provide remote robotic PCI.
Collapse
|
38
|
Robotic technology in interventional cardiology: Current status and future perspectives. Catheter Cardiovasc Interv 2017; 90:956-962. [DOI: 10.1002/ccd.27209] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/31/2017] [Accepted: 06/24/2017] [Indexed: 11/07/2022]
|
39
|
Inappropriate ICD Shock From Perceived Ventricular Fibrillation During Balloon Manipulation at the Time of Percutaneous Coronary Intervention. THE JOURNAL OF INVASIVE CARDIOLOGY 2017; 29:E94-E95. [PMID: 28756425] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
The authors demonstrate that device manipulation during percutaneous coronary intervention can result in "noise," which can be perceived as an arrhythmia resulting in an inappropriate shock. Although rare, this possibility should be considered when an operator encounters a difficult to traverse lesion in a patient with an ICD.
Collapse
|
40
|
Abstract
Robotic technology has been used in cardiovascular medicine for over a decade, and over that period its use has been expanded to interventional cardiology and percutaneous coronary and peripheral vascular interventions. The safety and feasibility of robotically assisted interventions has been demonstrated in multiple studies ranging from simple to complex coronary lesions, and in the treatment of iliofemoral and infrapopliteal disease. These studies have shown a reduction in operator exposure to harmful ionizing radiation, and the use of robotics has the intuitive benefit of alleviating the occupational hazard of operator orthopedic injuries. In addition to the interventional operator benefits, robotically assisted intervention has the potential to also be beneficial for patients by allowing more accurate lesion length measurement, stent placement, and patient radiation exposure; however, more investigation is required to elucidate these benefits fully.
Collapse
|
41
|
Demonstration of the Safety and Feasibility of Robotically Assisted Percutaneous Coronary Intervention in Complex Coronary Lesions. JACC Cardiovasc Interv 2017; 10:1320-1327. [DOI: 10.1016/j.jcin.2017.03.050] [Citation(s) in RCA: 90] [Impact Index Per Article: 12.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/15/2016] [Revised: 03/19/2017] [Accepted: 03/23/2017] [Indexed: 11/29/2022]
|
42
|
Plasma Phospholipids and Sphingolipids Identify Stent Restenosis After Percutaneous Coronary Intervention. JACC Cardiovasc Interv 2017. [DOI: 10.1016/j.jcin.2017.04.007] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
43
|
CRT-700.05 Safety, Feasibility And Success of Radial- Versus Femoral-Access Robotic Percutaneous Coronary Intervention: Results From the Multicenter PRECISION Registry. JACC Cardiovasc Interv 2017. [DOI: 10.1016/j.jcin.2016.12.200] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
44
|
The Prevalence of Lipoprotein(a) Measurement and Degree of Elevation Among 2710 Patients With Calcific Aortic Valve Stenosis in an Academic Echocardiography Laboratory Setting. Angiology 2017; 68:795-798. [DOI: 10.1177/0003319716688415] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Lipoprotein(a; Lp[a]) and its associated oxidized phospholipids are causal, genetic risk factors for calcific aortic valve stenosis (CAVS). We determined the prevalence of Lp(a) measurement among 2710 patients with CAVS and 1369 control patients (∼50% of study group) without CAVS with an echocardiogram between January 2010 and February 2016 in an academic echocardiography laboratory. Lipoprotein(a) measurements were performed at a referral laboratory using an isoform-independent assay. The prevalence of any Lp(a) measurement was 4.6% (124 of the 2710) in patients with CAVS and 3.1% (42 of the 1369) in the control group ( P = .021). In patients with CAVS, mean (standard deviation) Lp(a) levels were 38 (54) mg/dL and median (interquartile range) Lp(a) levels were 14 (6-48) mg/dL. Of the 124 patients with CAVS having Lp(a) measurements, 83 (66.9%) had Lp(a) <30 mg/dL and 41 (33.1%) had Lp(a) ≥30 mg/dL. This study reflects low physician testing of Lp(a) levels in CAVS. Given the role of Lp(a) as a causal risk factor for CAVS, and the ongoing development of therapies to normalize Lp(a) levels, our results suggest that Lp(a) measurements in CAVS should be more widely obtained in clinical practice.
Collapse
|
45
|
Routine transferrin saturation measurement in liver clinic patients increases detection of hereditary haemochromatosis. Ann Clin Biochem 2016; 40:521-7. [PMID: 14503989 DOI: 10.1258/000456303322326434] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Background: Hereditary haemochromatosis (HH) is one of the commonest genetic disorders in European populations. Transferrin saturation (TFS) measurement has been advocated as a phenotypic screening test to improve detection. We undertook a prospective study to examine the value of routine TFS measurement in detecting new cases of HH in unselected liver clinic attenders. Methods: Non-fasting TFS was measured in new patients. HH mutations were determined in those with elevated TFS (>45%) and all who underwent liver biopsy. Liver biopsy was performed in 349 patients, including all found to be C282Y homozygotes or compound heterozygotes. Results: Of 667 new patients attending over 5 years, 156 had TFS >45% and 18 had significant mutations (12 C282Y homozygotes and six compound heterozygotes). Eleven of the 12 C282Y homozygotes identified had an elevated TFS and 10 had significant hepatic siderosis. Only two of the six compound heterozygotes had an elevated TFS and hepatic siderosis. Conclusions: The prevalence of new HH cases in patients of European origin attending a liver clinic, detected by phenotypic screening over a 5-year period, was 2.8%. All were identified by a TFS cut off >45%, but TFS >60% provided the best combination of sensitivity and specificity for detecting C282Y homozygosity.
Collapse
|
46
|
New developments in the clinical use of drug-coated balloon catheters in peripheral arterial disease. MEDICAL DEVICES-EVIDENCE AND RESEARCH 2016; 9:161-74. [PMID: 27418859 PMCID: PMC4935119 DOI: 10.2147/mder.s86473] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Peripheral arterial disease (PAD) involving the lower extremity is a major source of morbidity and mortality. Clinical manifestations of PAD span the spectrum from lifestyle limiting claudication to ulceration and gangrene leading to amputation. Advancements including balloon angioplasty, self-expanding stents, drug-eluting stents, and atherectomy have resulted in high technical success rates for endovascular therapy in patients with PAD. However, these advances have been limited by somewhat high rates of clinical restenosis and clinically driven target lesion revascularization. The recent introduction of drug-coated balloon technology shows promise in limiting neointimal hyperplasia induced by vascular injury after endovascular therapies. This review summarizes the contemporary clinical data in the emerging area of drug-coated balloons.
Collapse
|
47
|
Effect of Serum Fibrinogen, Total Stent Length, and Type of Acute Coronary Syndrome on 6-Month Major Adverse Cardiovascular Events and Bleeding After Percutaneous Coronary Intervention. Am J Cardiol 2016; 117:1575-1581. [PMID: 27040574 DOI: 10.1016/j.amjcard.2016.02.032] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/11/2015] [Revised: 02/16/2016] [Accepted: 02/16/2016] [Indexed: 11/19/2022]
Abstract
This study evaluated the relation between baseline fibrinogen and 6-month major adverse cardiovascular events (MACE) and bleeding after percutaneous coronary intervention (PCI). Three hundred eighty-seven subjects (65.6 ± 16.1 years, 69.5% men, 26.9% acute coronary syndrome [ACS]) who underwent PCI with baseline fibrinogen and platelet reactivity (VerifyNow P2Y12 assay, Accumetrics, San Diego, California) measured were enrolled. Fibrinogen (368.8 ± 144.1 vs 316.8 ± 114.3 mg/dl; p = 0.001), total stent length (TSL; 44.5 ± 25.0 vs 32.2 ± 20.1 mm; p <0.001), and ACS presentation (40.6% vs 23.9%; p = 0.005) were independently associated with 6-month MACE rates (17.8%: myocardial infarction 9.8%, rehospitalization for ACS 3.6%, urgent revascularization 3.6%, stroke 0.5%, and death 0.3%). Measures of platelet reactivity were not associated with 6-month MACE. After multivariate analysis, fibrinogen ≥280 mg/dl (odds ratio [OR] 2.60, 95% CI 1.33 to 5.11, p = 0.005), TSL ≥32 mm (OR 3.21, 95% CI 1.82 to 5.64, p <0.001), and ACS presentation (OR 2.58, 95% CI 1.45 to 4.61, p = 0.001) were associated with higher 6-month MACE. In 271 subjects receiving chronic P2Y12 inhibitor therapy, 6-month Thrombolysis In Myocardial Infarction bleeding after PCI was 7.0%, but no difference in fibrinogen level (338.3 ± 109.7 vs 324.3 ± 113.8 mg/dl, p = 0.60) stratified by Thrombolysis In Myocardial Infarction bleeding was observed. In conclusion, elevated serum fibrinogen, ACS presentation, and longer TSL are independently associated with higher 6-month MACE after PCI, whereas no association with on-thienopyridine platelet reactivity and 6-month MACE was observed. Post-PCI bleeding was not associated with lower fibrinogen level.
Collapse
|
48
|
Renal frame count: a measure of renal flow that predicts success of renal artery stenting in hypertensive patients. Catheter Cardiovasc Interv 2016. [PMID: 26198066 DOI: 10.1002/ccd.25946] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVES Renal artery (RA) stenting can improve control of hypertension yet predicting clinical response remains difficult. We sought to determine the role of the renal frame count (RFC) (number of angiographic frames for contrast to reach distal renal parenchyma after initial RA opacification) as a predictor of improvement in blood pressure (BP) after RA stenting. METHODS Renal flow was quantified in 68 consecutive patients (age 72.5 ± 9.1 years, 72% male) undergoing RA stenting for refractory hypertension (BP ≥ 140/90 mm Hg despite treatment with two or more antihypertensive medications) by measuring RFC pre-RA stenting. Significant renal artery stenosis (RAS) was defined as a stenosis ≥ 70% by visual estimation on angiography. Baseline and 6-month follow-up BP was recorded. Clinical response was defined by a drop in systolic blood pressure (SBP) >10 mm Hg on the same or fewer number of anti-hypertensive medications. RESULTS Patients with RFC > 30 had SBP reduction (43.2 ± 25.7 mm Hg vs. 30.1 ± 31.3 mm Hg, P = 0.067), diastolic blood pressure reduction (9.1 ± 19.0 vs. -0.2 ± 13.4 mm Hg, P = 0.02), and mean arterial pressure reduction (23.8 ± 19.4 vs. 11.8 ± 16.1 mm Hg, P < 0.001) compared to patients with RFC ≤ 30. Furthermore, baseline RFC >30 was associated with a higher rate of clinical response to RA stenting (93.5% vs. 73%, P = 0.027). CONCLUSIONS RFC can be used as a clinical predictor of response to RA stenting. RFC > 30 was associated with reduction in BP after RA stenting and was predictive of clinical response. RFC provides a useful intraprocedural tool in assessing the severity of RAS and predicts the likelihood of clinical response following RA stenting.
Collapse
|
49
|
ROBOTIC VERSUS MANUAL PERCUTANEOUS CORONARY INTERVENTION: EFFECT ON PROCEDURE TIME FOR SIMPLE AND COMPLEX LESIONS. J Am Coll Cardiol 2016. [DOI: 10.1016/s0735-1097(16)30230-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
50
|
Invasive Cardiologists Are Exposed to Greater Left Sided Cranial Radiation. JACC Cardiovasc Interv 2015; 8:1197-1206. [DOI: 10.1016/j.jcin.2015.03.027] [Citation(s) in RCA: 56] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/10/2014] [Revised: 02/24/2015] [Accepted: 03/12/2015] [Indexed: 10/23/2022]
|