1
|
Abstract
Abstract
Four methods were developed for the determination of intact disopyramide phosphate in the presence of its degradation product. In the first and second methods, third-derivative spectrophotometry and first derivative of the ratio spectra were used. For the third-derivative spectrophotometric method, the peak amplitude was measured at 272 nm, while for the derivative ratio spectrophotometric method, disopyramide phosphate was determined by measuring the peak amplitude at 248 and 273 nm. Both methods were used for the determination of disopyramide phosphate in the concentration range 12.587.5 μg/mL, with corresponding mean recovery 100.8 ± 0.7% for the first method and 99.9 ± 0.7% and 99.6 ± 0.7% for the second method at 248 and 273 nm, respectively. In the third method, an ion selective electrode (ISE) was fabricated using phosphotungstic acid as an anionic exchanger, PVC as the polymer matrix, and dibutylsebacate as a plasticizer. The ISE was used for the determination of disopyramide phosphate in pure powder form in the concentration range 10-210-5 M. The slope was found to be 58.5 (mV/decade), and the average recovery was 99.9 ± 1.6%. The fourth method depended on the quantitative densitometric determination of the drug in concentration range of 0.252.5 μg/spot using silica gel 60 F245 plates and ethyl acetatechloroformammonium hydroxide (85 + 10 + 5, v/v/v) as the mobile phase, with corresponding mean accuracy of 100.3 1.1%. The 4 proposed methods were found to be specific for disopyramide phosphate in presence of up to 80% of its degradation product for the spectrophotometric methods, 90% of its degradation for the densitometric method, and 40% for the ISE method. The 4 proposed procedures were successfully applied for the determination of disopyramide phosphate in Norpace capsules. Statistical comparison between the results obtained by these methods and the official method of the drug was done, and no significant differences were found.
Collapse
|
2
|
Assessment of pectin-coated magnetite nanoparticles in low-energy water desalination applications. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2018; 25:18476-18483. [PMID: 29696545 DOI: 10.1007/s11356-018-2060-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/15/2017] [Accepted: 04/17/2018] [Indexed: 06/08/2023]
Abstract
Novel magnetite nanoparticles (NPs) modified with pectin coating were fabricated, characterized, and evaluated as potential draw solute in a forward osmosis (FO) process for water desalination applications. The prepared NPs had a spherical shape with an average diameter of 200 nm and saturation magnetization of 23.13 emu/g. Thermogravimetric analysis (TGA) and FTIR spectra elucidated the successful pectin coating on magnetite surface. The potential use of the fabricated NPs in water desalination was conducted via a newly developed lab-scale FO system. Deionized water, saline water (0.2, 0.5, and 1 g% NaCl solution), and real well water (TDS = 0.9 g%) were used as feed solutions. In all experiments, the water flux gradually decreased along with the extension of experimental time and NaCl rejection rate by the FO membrane was measured to be higher than 95%. Moreover, it was found that the pectin-coated magnetite NPs demonstrated to be able to draw clean water across the FO membrane from well water with a remarkable salt rejection of 97%. Thus, it is believed that the proposed FO system using pectin-coated magnetite NPs as draw solute can be a promising technique for desalination of well waters in an environmental-friendly and energy-saving manner.
Collapse
|
3
|
Comparative Assessment of the Effect of Hyper-glycosylation on the Pattern and Kinetics of Degradation of Darbepoetin Alfa using a Stability-Indicating Orthogonal Testing Protocol. J Chromatogr B Analyt Technol Biomed Life Sci 2018; 1072:405-414. [DOI: 10.1016/j.jchromb.2017.10.057] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2017] [Revised: 10/21/2017] [Accepted: 10/29/2017] [Indexed: 10/18/2022]
|
4
|
Evaluation of the combined effects of pegylation and glycosylation on the stability of erythropoietin using a stability-indicating SE-HPLC. Biologicals 2017; 50:129-136. [PMID: 28958787 DOI: 10.1016/j.biologicals.2017.08.012] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2017] [Revised: 08/23/2017] [Accepted: 08/24/2017] [Indexed: 10/18/2022] Open
Abstract
Recombinant human erythropoietin (rhEPO) is a commonly used biopharmaceutical for the treatment of anemia-associated disorders. Epogen; glycosylated erythropoietin (G-EPO) has short half-life and poor stability. Pegylated Epogen (Peg-G-EPO) was introduced to the market to overcome these limitations. The combined effects of pegylation and glycosylation on the stability of Peg-G-EPO was studied. Determination of Peg-G-EPO in the presence of its degradation products was achieved using SE-HPLC. The assay was validated according to ICH guidelines over concentration range of 50.00-320.00 μg/mL (r 0.9999). A mobile phase of 50 mM phosphate buffer (pH 6.5) with 300 mM sodium chloride and 20% ethanol was employed. Isocratic elution was carried out at 0.5 mL/min over run time of 30 min. Peg-G-EPO was found stable towards mechanical agitation only at low concentrations while it was stable towards repeated freeze/thaw; regardless of the concentration. Effect of temperature and pH were also investigated and Peg-G-EPO was found stable within narrow ranges. Results indicated formation of small molecular weight and very high molecular weight aggregates that have been filtered-off the column. Although Peg-G-EPO was found relatively more stable than its non-pegylated but glycosylated version, results indicated the need for careful stability-assessment of Peg-G-EPO.
Collapse
|
5
|
Challenge Approach of an Inexpensive Electrochemical Sensor for Rapid Selective Determination of two Non-classical β-Lactams in Presence of Different Degradants and Interference Substances. ELECTROANAL 2017. [DOI: 10.1002/elan.201700431] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
6
|
Correlation between Dynamic Light Scattering and Size Exclusion High Performance Liquid Chromatography for Monitoring the Effect of pH on Stability of Biopharmaceuticals. J Chromatogr B Analyt Technol Biomed Life Sci 2017; 1060:1-9. [DOI: 10.1016/j.jchromb.2017.05.029] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2017] [Revised: 05/24/2017] [Accepted: 05/25/2017] [Indexed: 10/19/2022]
|
7
|
Zero and second-derivative synchronous fluorescence spectroscopy for the quantification of two non-classical β-lactams in pharmaceutical vials: Application to stability studies. LUMINESCENCE 2017; 32:1517-1527. [DOI: 10.1002/bio.3353] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2016] [Revised: 03/15/2017] [Accepted: 04/18/2017] [Indexed: 11/06/2022]
|
8
|
Development and validation of HPLC and CE methods for simultaneous determination of amlodipine and atorvastatin in the presence of their acidic degradation products in tablets. ACTA PHARMACEUTICA 2016; 66:479-490. [PMID: 27749253 DOI: 10.1515/acph-2016-0040] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 05/01/2016] [Indexed: 11/15/2022]
Abstract
Two methods were developed for separation and quantitation of amlodipine (AML) and atorvastatin (ATV) in the presence of their acidic degradation products. The first method was a simple isocratic RP-HPLC method while the second was capillary electrophoresis (CE). Degradation products were obtained by acidic hydrolysis of the two drugs and their structures were elucidated for the first time by IR and MS spectra. Degradation products did not interfere with the determination of either drug and the assays were therefore stability-indicating. The linearity of the proposed methods was established over the ranges 1-50 μg mL-1 for AML and ATV in the HPLC method and in the range of 3-50 and 4-50 μg mL-1 for AML and ATV, respectively, in the CE method. The proposed methods were validated according to ICH guidelines. The methods were successfully applied to estimation of AML and ATV in combined tablets.
Collapse
|
9
|
Immunoaffinity extraction using conformation-dependent antibodies coupled to SE-HPLC for the development of stability and potency-indicating assay for quadrivalent human papillomavirus vaccine. J Chromatogr B Analyt Technol Biomed Life Sci 2016; 1032:211-217. [PMID: 27037127 DOI: 10.1016/j.jchromb.2016.03.036] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2016] [Revised: 03/12/2016] [Accepted: 03/23/2016] [Indexed: 10/22/2022]
Abstract
Quadrivalent human papillomavirus (HPV) vaccine is formulated of four types of non-infectious recombinant virus like particles (VLPs) that are structurally and immunologically similar to the corresponding infectious HPV virus types 6, 11, 16 and 18. With almost identical physical, chemical and structural properties of the four types of VLPs, ELISA remains the only approved in vitro potency testing assay. In this study, an alternative industry-friendly, stability- and potency-indicating assay protocol was developed and validated for the determination of HPV vaccine. Vacuum-driven immunoaffinity extraction (IAE) was employed using type-specific, conformation-dependent antibodies against each type of HPV VLPs. ELISA assay was employed to evaluate the ability of IAE columns to specifically separate each of the four types of VLPs from their quadrivalent mixture. Mean percentage recoveries of 76.76±2.69, 69.12±5.79, 84.86±5.25 and 71.14±4.50% were obtained for VLPs types 6, 11, 16 and 18, respectively with no significant interference in each case. Antigen content was then determined using SE-HPLC over a concentration range of 5.00-20.00μg/mL (r>0.998) for VLPs type 6, 11, 16 and 18, respectively. The SE-HPLC assay was found accurate and precise (RSD<10.00%) with LOD ranging from 1.23-3.85μg/mL. The assay protocol was found superior to conventional ELISA assay with respect to simplicity, total analysis time and cost. Good correlation between the results of analysis obtained using IAE-SE-HPLC and ELISA demonstrated the suitability of the suggested assay protocol for stability and potency assessment with a good potential for implementation for batch release. This approach should be applicable for quality assessment of other vaccine preparations based on VLPs.
Collapse
|
10
|
A validated direct thin-layer chromatographic separation and enantioselective determination of racemic centrally acting drugs using ion-pair and ligand-exchange chiral selectors: A thermodynamic study of complexation. JPC-J PLANAR CHROMAT 2016; 29:176-183. [DOI: 10.1556/1006.2016.29.3.2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
|
11
|
Comparative study between recent methods manipulating ratio spectra and classical methods based on two-wavelength selection for the determination of binary mixture of antazoline hydrochloride and tetryzoline hydrochloride. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2016; 159:98-105. [PMID: 26836449 DOI: 10.1016/j.saa.2016.01.014] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2015] [Revised: 12/21/2015] [Accepted: 01/11/2016] [Indexed: 06/05/2023]
Abstract
A comparative study was developed between two classical spectrophotometric methods (dual wavelength method and Vierordt's method) and two recent methods manipulating ratio spectra (ratio difference method and first derivative of ratio spectra method) for simultaneous determination of Antazoline hydrochloride (AN) and Tetryzoline hydrochloride (TZ) in their combined pharmaceutical formulation and in the presence of benzalkonium chloride as a preservative without preliminary separation. The dual wavelength method depends on choosing two wavelengths for each drug in a way so that the difference in absorbance at those two wavelengths is zero for the other drug. While Vierordt's method, is based upon measuring the absorbance and the absorptivity values of the two drugs at their λ(max) (248.0 and 219.0 nm for AN and TZ, respectively), followed by substitution in the corresponding Vierordt's equation. Recent methods manipulating ratio spectra depend on either measuring the difference in amplitudes of ratio spectra between 255.5 and 269.5 nm for AN and 220.0 and 273.0 nm for TZ in case of ratio difference method or computing first derivative of the ratio spectra for each drug then measuring the peak amplitude at 250.0 nm for AN and at 224.0 nm for TZ in case of first derivative of ratio spectrophotometry. The specificity of the developed methods was investigated by analyzing different laboratory prepared mixtures of the two drugs. All methods were applied successfully for the determination of the selected drugs in their combined dosage form proving that the classical spectrophotometric methods can still be used successfully in analysis of binary mixture using minimal data manipulation rather than recent methods which require relatively more steps. Furthermore, validation of the proposed methods was performed according to ICH guidelines; accuracy, precision and repeatability are found to be within the acceptable limits. Statistical studies showed that the methods can be competitively applied in quality control laboratories.
Collapse
|
12
|
Advanced stability indicating chemometric methods for quantitation of amlodipine and atorvastatin in their quinary mixture with acidic degradation products. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2016; 154:58-66. [PMID: 26513228 DOI: 10.1016/j.saa.2015.10.007] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2015] [Revised: 06/02/2015] [Accepted: 10/04/2015] [Indexed: 06/05/2023]
Abstract
Two advanced, accurate and precise chemometric methods are developed for the simultaneous determination of amlodipine besylate (AML) and atorvastatin calcium (ATV) in the presence of their acidic degradation products in tablet dosage forms. The first method was Partial Least Squares (PLS-1) and the second was Artificial Neural Networks (ANN). PLS was compared to ANN models with and without variable selection procedure (genetic algorithm (GA)). For proper analysis, a 5-factor 5-level experimental design was established resulting in 25 mixtures containing different ratios of the interfering species. Fifteen mixtures were used as calibration set and the other ten mixtures were used as validation set to validate the prediction ability of the suggested models. The proposed methods were successfully applied to the analysis of pharmaceutical tablets containing AML and ATV. The methods indicated the ability of the mentioned models to solve the highly overlapped spectra of the quinary mixture, yet using inexpensive and easy to handle instruments like the UV-VIS spectrophotometer.
Collapse
|
13
|
Mean centering of double divisor ratio spectra, a novel spectrophotometric method for analysis of ternary mixtures. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2016; 153:132-142. [PMID: 26298680 DOI: 10.1016/j.saa.2015.07.109] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2015] [Revised: 07/29/2015] [Accepted: 07/30/2015] [Indexed: 06/04/2023]
Abstract
A novel spectrophotometric method was developed for determination of ternary mixtures without previous separation, showing significant advantages over conventional methods. The new method is based on mean centering of double divisor ratio spectra. The mathematical explanation of the procedure is illustrated. The method was evaluated by determination of model ternary mixture and by the determination of Amlodipine (AML), Aliskiren (ALI) and Hydrochlorothiazide (HCT) in laboratory prepared mixtures and in a commercial pharmaceutical preparation. For proper presentation of the advantages and applicability of the new method, a comparative study was established between the new mean centering of double divisor ratio spectra (MCDD) and two similar methods used for analysis of ternary mixtures, namely mean centering (MC) and double divisor of ratio spectra-derivative spectrophotometry (DDRS-DS). The method was also compared with a reported one for analysis of the pharmaceutical preparation. The method was validated according to the ICH guidelines and accuracy, precision, repeatability and robustness were found to be within the acceptable limits.
Collapse
|
14
|
Removal of cationic and anionic dyes from aqueous solution with magnetite/pectin and magnetite/silica/pectin hybrid nanocomposites: kinetic, isotherm and mechanism analysis. RSC Adv 2016. [DOI: 10.1039/c5ra23452b] [Citation(s) in RCA: 141] [Impact Index Per Article: 17.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023] Open
Abstract
Novel adsorbents, magnetite nanoparticles modified with pectin shell and silica/pectin double shell, were fabricated and tested for single dye and dye mixture adsorption from water samples.
Collapse
|
15
|
Continuous Wavelet Transform, a powerful alternative to Derivative Spectrophotometry in analysis of binary and ternary mixtures: A comparative study. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2015; 151:945-955. [PMID: 26186613 DOI: 10.1016/j.saa.2015.06.100] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/21/2015] [Revised: 06/20/2015] [Accepted: 06/25/2015] [Indexed: 06/04/2023]
Abstract
A comparative study was established between two signal processing techniques showing the theoretical algorithm for each method and making a comparison between them to indicate the advantages and limitations. The methods under study are Numerical Differentiation (ND) and Continuous Wavelet Transform (CWT). These methods were studied as spectrophotometric resolution tools for simultaneous analysis of binary and ternary mixtures. To present the comparison, the two methods were applied for the resolution of Bisoprolol (BIS) and Hydrochlorothiazide (HCT) in their binary mixture and for the analysis of Amlodipine (AML), Aliskiren (ALI) and Hydrochlorothiazide (HCT) as an example for ternary mixtures. By comparing the results in laboratory prepared mixtures, it was proven that CWT technique is more efficient and advantageous in analysis of mixtures with severe overlapped spectra than ND. The CWT was applied for quantitative determination of the drugs in their pharmaceutical formulations and validated according to the ICH guidelines where accuracy, precision, repeatability and robustness were found to be within the acceptable limit.
Collapse
|
16
|
Application of the ratio difference spectrophotometry to the determination of ibuprofen and famotidine in their combined dosage form: comparison with previously published spectrophotometric methods. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2015; 143:251-255. [PMID: 25733252 DOI: 10.1016/j.saa.2015.02.050] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2014] [Revised: 02/10/2015] [Accepted: 02/12/2015] [Indexed: 06/04/2023]
Abstract
Ratio difference spectrophotometric method was developed for the determination of ibuprofen and famotidine in their mixture form. Ibuprofen and famotidine were determined in the presence of each other by the ratio difference spectrophotometric (RD) method where linearity was obtained from 50 to 600μg/mL and 2.5 to 25μg/mL for ibuprofen and famotidine, respectively. The suggested method was validated according to ICH guidelines and successfully applied for the analysis of ibuprofen and famotidine in their pharmaceutical dosage forms without interference from any additives or excipients.
Collapse
|
17
|
Different signal processing techniques of ratio spectra for spectrophotometric resolution of binary mixture of bisoprolol and hydrochlorothiazide; a comparative study. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2015; 140:334-343. [PMID: 25615684 DOI: 10.1016/j.saa.2014.12.107] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/14/2014] [Revised: 12/10/2014] [Accepted: 12/28/2014] [Indexed: 06/04/2023]
Abstract
Five signal processing techniques were applied to ratio spectra for quantitative determination of bisoprolol (BIS) and hydrochlorothiazide (HCT) in their binary mixture. The proposed techniques are Numerical Differentiation of Ratio Spectra (ND-RS), Savitsky-Golay of Ratio Spectra (SG-RS), Continuous Wavelet Transform of Ratio Spectra (CWT-RS), Mean Centering of Ratio Spectra (MC-RS) and Discrete Fourier Transform of Ratio Spectra (DFT-RS). The linearity of the proposed methods was investigated in the range of 2-40 and 1-22 μg/mL for BIS and HCT, respectively. The proposed methods were applied successfully for the determination of the drugs in laboratory prepared mixtures and in commercial pharmaceutical preparations and standard deviation was less than 1.5. The five signal processing techniques were compared to each other and validated according to the ICH guidelines and accuracy, precision, repeatability and robustness were found to be within the acceptable limit.
Collapse
|
18
|
Development and validation of chromatographic methods for simultaneous determination of ibuprofen and famotidine in presence of related substances in pharmaceutical formulations. Acta Chim Slov 2015; 62:45-51. [PMID: 25830959 DOI: 10.17344/acsi.2014.703] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
Two validated methods for the simultaneous determination of ibuprofen and famotidine in the presence of ibuprofen impurity (4-isobutylacetophenone) and or famotidine degradation products were described. The first method was a simple TLC method where separation was performed on silica gel platesusing ethyl acetate: methanol: ammonia (9:2:1, by volume) as a mobile phase. Rf values were found to be 0.40, 0.94, 0.66, 0.27, 0.83 for ibuprofen, 4-isobutylacetophenone, famotidine, famotidine acid and basic degradation products, respectively. The second method is by HPLC on C18 column using methanol: phosphate buffer pH 3 (80:20, v/v) as a mobile phase. Retention times were found to be 2.2, 9.9, and 8.6 for famotidine, ibuprofen, and 4-isobutylacetophenone, respectively. Both methods were validated according to the ICH guidelines and applied for the determination of the two drugs in pure powder and combined dosage form without interference from the excipients.
Collapse
|
19
|
Validated green high-performance liquid chromatographic methods for the determination of coformulated pharmaceuticals: A comparison with reported conventional methods. J Sep Sci 2015; 38:757-63. [DOI: 10.1002/jssc.201401151] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2014] [Revised: 11/22/2014] [Accepted: 12/09/2014] [Indexed: 11/09/2022]
|
20
|
A novel surfactant silica gel modified carbon paste electrode in micellar media for selective determination of diminazene aceturate in the presence of its stabilizer. RSC Adv 2015. [DOI: 10.1039/c5ra06292f] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
A novel irreversible anodic voltammetric method was introduced for selective determination of diminazene aceturate in the presence of phenazone as a stabilizer.
Collapse
|
21
|
Assessment of the Degradation Pattern and Extent of PEG Interferon α-2b Using a Stability-Indicating SE-HPLC Assay. Chromatographia 2014. [DOI: 10.1007/s10337-014-2760-3] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
22
|
Different approaches in Partial Least Squares and Artificial Neural Network models applied for the analysis of a ternary mixture of Amlodipine, Valsartan and Hydrochlorothiazide. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2014; 122:744-750. [PMID: 24378624 DOI: 10.1016/j.saa.2013.11.045] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2013] [Revised: 09/10/2013] [Accepted: 11/03/2013] [Indexed: 06/03/2023]
Abstract
Different chemometric models were applied for the quantitative analysis of Amlodipine (AML), Valsartan (VAL) and Hydrochlorothiazide (HCT) in ternary mixture, namely, Partial Least Squares (PLS) as traditional chemometric model and Artificial Neural Networks (ANN) as advanced model. PLS and ANN were applied with and without variable selection procedure (Genetic Algorithm GA) and data compression procedure (Principal Component Analysis PCA). The chemometric methods applied are PLS-1, GA-PLS, ANN, GA-ANN and PCA-ANN. The methods were used for the quantitative analysis of the drugs in raw materials and pharmaceutical dosage form via handling the UV spectral data. A 3-factor 5-level experimental design was established resulting in 25 mixtures containing different ratios of the drugs. Fifteen mixtures were used as a calibration set and the other ten mixtures were used as validation set to validate the prediction ability of the suggested methods. The validity of the proposed methods was assessed using the standard addition technique.
Collapse
|
23
|
Quality in the pharmaceutical industry - A literature review. Saudi Pharm J 2013; 23:463-9. [PMID: 26594110 PMCID: PMC4605917 DOI: 10.1016/j.jsps.2013.11.004] [Citation(s) in RCA: 54] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2013] [Accepted: 11/10/2013] [Indexed: 11/28/2022] Open
Abstract
Objectives The aim of this study is to:Highlight the most important guidelines and practices of quality in the pharmaceutical industry. Organize such guidelines and practices to create a guide to pave the way for other researchers who would like to dig deeper into these guidelines and practices.
Design A review was conducted of 102 publications; 56 publications were concerned with the pharmaceutical quality directly while 46 publications were concerned with the general quality practices. The content of those sources was analyzed and the following themes were identified:Research theme 1: Guidelines of the pharmaceutical quality. Research theme 2: General practices recently applied in the pharmaceutical industry.
Main outcome measures The following guidelines were identified and reviewed: WHO guidelines, FDA guidelines, EU guidelines and ICH guidelines in the research theme I. In research theme II; the following topics were identified and reviewed: quality risk management, quality by design, corrective actions and preventive actions, process capability analysis, Six Sigma, process analytical technology, lean manufacturing, total quality management, ISO series and HACCP. Results Upon reviewing the previously highlighted guidelines and the practices that are widely applied in the pharmaceutical industry, it was noticed that there is an abundant number of papers and articles that explain the general guidelines and practices but the literature lack those describing application; case studies of the pharmaceutical factories applying those guidelines and significance of those guidelines and practices. Conclusions It is recommended that the literature would invest more in the area of application and significance of guidelines and practices. New case studies should be done to prove the feasibility of such practices.
Collapse
|
24
|
Comparative study between derivative spectrophotometry and multivariate calibration as analytical tools applied for the simultaneous quantitation of Amlodipine, Valsartan and Hydrochlorothiazide. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2013; 113:215-223. [PMID: 23727675 DOI: 10.1016/j.saa.2013.04.068] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2012] [Revised: 03/06/2013] [Accepted: 04/14/2013] [Indexed: 06/02/2023]
Abstract
Four simple, accurate and specific methods were developed and validated for the simultaneous estimation of Amlodipine (AML), Valsartan (VAL) and Hydrochlorothiazide (HCT) in commercial tablets. The derivative spectrophotometric methods include Derivative Ratio Zero Crossing (DRZC) and Double Divisor Ratio Spectra-Derivative Spectrophotometry (DDRS-DS) methods, while the multivariate calibrations used are Principal Component Regression (PCR) and Partial Least Squares (PLSs). The proposed methods were applied successfully in the determination of the drugs in laboratory-prepared mixtures and in commercial pharmaceutical preparations. The validity of the proposed methods was assessed using the standard addition technique. The linearity of the proposed methods is investigated in the range of 2-32, 4-44 and 2-20 μg/mL for AML, VAL and HCT, respectively.
Collapse
|
25
|
SIMULTANEOUS DETERMINATION OF PRAMOCAINE HCL AND HYDROCORTISONE ACETATE IN PHARMACEUTICAL DOSAGE FORM. J LIQ CHROMATOGR R T 2013. [DOI: 10.1080/10826076.2012.725696] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
26
|
Novel stability indicating methods for the determination of certain synthetic estrogen level modifiers. ACTA ACUST UNITED AC 2013. [DOI: 10.1016/j.bfopcu.2012.11.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
27
|
Three different methods for determination of binary mixture of Amlodipine and Atorvastatin using dual wavelength spectrophotometry. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2013; 104:70-76. [PMID: 23266678 DOI: 10.1016/j.saa.2012.11.079] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/04/2012] [Revised: 11/10/2012] [Accepted: 11/23/2012] [Indexed: 06/01/2023]
Abstract
Three simple, specific, accurate and precise spectrophotometric methods depending on the proper selection of two wavelengths are developed for the simultaneous determination of Amlodipine besylate (AML) and Atorvastatin calcium (ATV) in tablet dosage forms. The first method is the new Ratio Difference method, the second method is the Bivariate method and the third one is the Absorbance Ratio method. The calibration curve is linear over the concentration range of 4-40 and 8-32 μg/mL for AML and ATV, respectively. These methods are tested by analyzing synthetic mixtures of the above drugs and they are applied to commercial pharmaceutical preparation of the subjected drugs. Methods are validated according to the ICH guidelines and accuracy, precision, repeatability and robustness are found to be within the acceptable limit. The mathematical explanation of the procedures is illustrated.
Collapse
|
28
|
Different stability-indicating chromatographic techniques for the determination of netobimin. JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY 2012; 2012:754650. [PMID: 22567566 PMCID: PMC3335307 DOI: 10.1155/2012/754650] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/17/2011] [Revised: 01/12/2012] [Accepted: 01/20/2012] [Indexed: 05/31/2023]
Abstract
Two simple, accurate, and sensitive methods were developed for the determination of netobimin in the presence of its degradation product. Method (A) was an HPLC method, performed on C18 column using acetonitrile/methanol/0.01 M potassium dihydrogen phosphate (56 : 14 : 30 by volume) as a mobile phase with a flow rate of 0.5 mL/min. Detection was performed at 254 nm. Method (B) was a TLC method, using silica gel 60 F(254) plates; the optimized mobile phase was toluene/methanol/chloroform/ammonium hydroxide (5 : 4 : 6 : 0.1 by volume). The spots were scanned densitometrically at 346 nm. Linearity ranges were 1-10 μg/mL for method (A) and 0.5-5 μg/band for method (B), and the mean percentage recoveries were 99.3 ± 0.7% and 99.7 ± 0.7% for methods (A) and (B), respectively. The proposed methods were found to be specific for netobimin in the presence of up to 90% of its degradation product. Statistical comparison between the results obtained by these methods and the manufacturer method was done, and no significance difference was obtained.
Collapse
|
29
|
Three different spectrophotometric methods manipulating ratio spectra for determination of binary mixture of Amlodipine and Atorvastatin. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2011; 83:140-148. [PMID: 21908232 DOI: 10.1016/j.saa.2011.08.005] [Citation(s) in RCA: 61] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/05/2011] [Revised: 06/19/2011] [Accepted: 08/08/2011] [Indexed: 05/31/2023]
Abstract
Three simple, specific, accurate and precise spectrophotometric methods manipulating ratio spectra are developed for the simultaneous determination of Amlodipine besylate (AM) and Atorvastatin calcium (AT) in tablet dosage forms. The first method is first derivative of the ratio spectra ((1)DD), the second is ratio subtraction and the third is the method of mean centering of ratio spectra. The calibration curve is linear over the concentration range of 3-40 and 8-32 μg/ml for AM and AT, respectively. These methods are tested by analyzing synthetic mixtures of the above drugs and they are applied to commercial pharmaceutical preparation of the subjected drugs. Standard deviation is <1.5 in the assay of raw materials and tablets. Methods are validated as per ICH guidelines and accuracy, precision, repeatability and robustness are found to be within the acceptable limit.
Collapse
|
30
|
Comparative study of 2-hydroxy propyl beta cyclodextrin and calixarene as ionophores in potentiometric ion-selective electrodes for neostigmine bromide. Talanta 2011; 85:913-8. [DOI: 10.1016/j.talanta.2011.04.071] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2011] [Revised: 04/27/2011] [Accepted: 04/28/2011] [Indexed: 10/18/2022]
|
31
|
Stability-indicating spectrophotometric and spectrodensitometric methods for the determination of diacerein in the presence of its degradation product. Drug Test Anal 2010; 3:221-7. [PMID: 21500366 DOI: 10.1002/dta.213] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2010] [Revised: 09/23/2010] [Accepted: 09/24/2010] [Indexed: 11/08/2022]
Abstract
Three sensitive, selective, and precise stability-indicating methods for the determination of the novel osteoarthritis drug, diacerein (DIA) in the presence of its alkaline degradation product (active metabolite, rhein) and in pharmaceutical formulation were developed and validated. The first method is a first derivative (D(1) ) spectrophotometric one, which allows the determination of DIA in the presence of its degradate at 322 nm (corresponding to zero crossing of the degradate) over a concentration range of 4-40 µg/mL with mean percentage recovery 100.21 ± 0.833. The second method is the first derivative of the ratio spectra (DD(1) ) by measuring the peak amplitude at 352 nm over the same concentration range as (D(1) ) spectrophotometric method, with mean percentage recovery 100.09 ± 0.912. The third method is a TLC-densitometric one, where DIA was separated from its degradate on silica gel plates using ethyl acetate:methanol:chloroform (8:1.5:0.5 v:v:v) as a developing system. This method depends on quantitative densitometric evaluation of thin layer chromatogram of DIA at 340 nm over a concentration range of 1-10 µg/spot, with mean percentage recovery 100.24 ± 1.412. The selectivity of the proposed methods was tested using laboratory-prepared mixtures. The proposed methods have been successfully applied to the analysis of DIA in pharmaceutical dosage forms without interference from other dosage form additives and the results were statistically compared with reference method.
Collapse
|
32
|
Spectrophotometric and spectrodensitometric methods for the determination of rivastigmine hydrogen tartrate in presence of its degradation product. Drug Test Anal 2010; 2:225-33. [PMID: 20468010 DOI: 10.1002/dta.121] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Three sensitive, selective and precise stability-indicating methods for the determination of the anti-Alzheimer's drug, rivastigmine hydrogen tartrate (RIV) in the presence of its alkaline degradation product (major metabolite, NAP 226-90) and in pharmaceutical formulation were developed and validated. The first method is a second derivative (D(2)) spectrophotometric one, which allows the determination of RIV in the presence of its degradate at 262 nm (corresponding to zero crossing of the degradate) over a concentration range of 50-500 microg/ml with mean percentage recovery 100.18 +/- 0.628. The second method is the first derivative of the ratio spectra (DD(1)) by measuring the peak amplitude at 272 nm over the same concentration range as (D(2)) spectrophotometric method, with mean percentage recovery 99.97 +/- 0.641. The third method is a TLC-densitometric one, where RIV was separated from its degradate on silica gel plates using methanol:butanol:H(2)O:ammonia (5:4:1:0.01 v:v:v) as a developing system. This method depends on the quantitative densitometric evaluation of thin layer chromatogram of RIV at 263 nm over a concentration range of 20-160 microg/spot, with mean percentage recovery 100.19 +/- 1.344. The selectivity of the proposed methods was tested using laboratory-prepared mixtures. The proposed methods have been successfully applied to the analysis of RIV in pharmaceutical dosage forms without interference from other dosage form additives and the results were statistically compared with reference method.
Collapse
|
33
|
Membrane electrodes for the determination of pyridostigmine bromide. J AOAC Int 2009; 92:1631-1638. [PMID: 20166579] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Two pyridostigmine bromide (PB) selective electrodes were investigated with 2-nitrophenyl octyl ether as a plasticizer in a polymeric matrix of carboxylated polyvinyl chloride (PVC-COOH), based on the interaction between the drug solution and the dissociated COOH groups in the PVC-COOH. One of the sensors was fabricated by using PVC-COOH only as anionic site without incorporation of an ionophore (sensor 1). The second sensor was constructed by using 2-hydroxy propyl beta-cyclodextrin as an ionophore (sensor 2). Linear responses of PB within a concentration range of 10(-3)-10(-2) and 10(-5)-10(-2) M, with slopes of 51.9 +/- 0.31 and 56.7 +/- 0.40 mV/decade over pH range of 5-10 were obtained using sensors 2 and 1, respectively. The proposed method displayed useful analytical characteristics for determination of PB in tablets with average recoveries of 100.22 +/- 0.62, and 100.15 +/- 0.72, and in plasma with average recoveries of 99.14 +/- 1.19 and 99.79 +/- 0.72, for sensors 2 and 1, respectively. The utility of 2-hydroxy propyl beta-cyclodextrin as an ionophore has a significant influence on increasing both membrane sensitivity and selectivity of sensor 2 in comparison with sensor 1. The methods were also used to determine the intact drug in the presence of its degradate, and thus could be used as stability-indicating methods. The results obtained by the proposed procedures were statistically analyzed and compared with those obtained by the U.S. Pharmacopeia method. No significant difference for either accuracy or precision was observed.
Collapse
|
34
|
Abstract
Abstract
Two pyridostigmine bromide (PB) selective electrodes were investigated with 2-nitrophenyl octyl ether as a plasticizer in a polymeric matrix of carboxylated polyvinyl chloride (PVC-COOH), based on the interaction between the drug solution and the dissociated COOH groups in the PVC-COOH. One of the sensors was fabricated by using PVC-COOH only as anionic site without incorporation of an ionophore (sensor 1). The second sensor was constructed by using 2-hydroxy propyl -cyclodextrin as an ionophore (sensor 2). Linear responses of PB within a concentration range of 103102 and 105102 M, with slopes of 51.9 0.31 and 56.7 0.40 mV/decade over pH range of 510 were obtained using sensors 2 and 1, respectively. The proposed method displayed useful analytical characteristics for determination of PB in tablets with average recoveries of 100.22 0.62, and 100.15 0.72, and in plasma with average recoveries of 99.14 1.19 and 99.79 0.72, for sensors 2 and 1, respectively. The utility of 2-hydroxy propyl -cyclodextrin as an ionophore has a significant influence on increasing both membrane sensitivity and selectivity of sensor 2 in comparison with sensor 1. The methods were also used to determine the intact drug in the presence of its degradate, and thus could be used as stability-indicating methods. The results obtained by the proposed procedures were statistically analyzed and compared with those obtained by the U.S. Pharmacopeia method. No significant difference for either accuracy or precision was observed.
Collapse
|
35
|
Stability-indicating methods for the determination of disopyramide phosphate. J AOAC Int 2006; 89:976-86. [PMID: 16915833] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
Four methods were developed for the determination of intact disopyramide phosphate in the presence of its degradation product. In the first and second methods, third-derivative spectrophotometry and first derivative of the ratio spectra were used. For the third-derivative spectrophotometric method, the peak amplitude was measured at 272 nm, while for the derivative ratio spectrophotometric method, disopyramide phosphate was determined by measuring the peak amplitude at 248 and 273 nm. Both methods were used for the determination of disopyramide phosphate in the concentration range 12.5-87.5 microg/mL, with corresponding mean recovery 100.8 +/- 0.7% for the first method and 99.9 +/- 0.7% and 99.6 +/- 0.7% for the second method at 248 and 273 nm, respectively. In the third method, an ion selective electrode (ISE) was fabricated using phosphotungstic acid as an anionic exchanger, PVC as the polymer matrix, and dibutylsebacate as a plasticizer. The ISE was used for the determination of disopyramide phosphate in pure powder form in the concentration range 10(-2)-10(-5) M. The slope was found to be 58.5 (mV/decade), and the average recovery was 99.9 +/- 1.6%. The fourth method depended on the quantitative densitometric determination of the drug in concentration range of 0.25-2.5 microg/spot using silica gel 60 F245 plates and ethyl acetate-chloroform-ammonium hydroxide (85 + 10 + 5, v/v/v) as the mobile phase, with corresponding mean accuracy of 100.3 +/- 1.1%. The 4 proposed methods were found to be specific for disopyramide phosphate in presence of up to 80% of its degradation product for the spectrophotometric methods, 90% of its degradation for the densitometric method, and 40% for the ISE method. The 4 proposed procedures were successfully applied for the determination of disopyramide phosphate in Norpace capsules. Statistical comparison between the results obtained by these methods and the official method of the drug was done, and no significant differences were found.
Collapse
|
36
|
Simultaneous determination of domperidone and cinnarizine in a binary mixture using derivative spectrophotometry, partial least squares and principle component regression calibration. Anal Bioanal Chem 2003; 375:211-6. [PMID: 12560964 DOI: 10.1007/s00216-002-1666-3] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2002] [Revised: 09/20/2002] [Accepted: 10/25/2002] [Indexed: 11/25/2022]
Abstract
This work is concerned with the simultaneous determination of domperidone maleate (DOM) and cinnarizine (CINN) in a binary mixture form, without previous separation, by two different techniques. The first method is the application of derivative spectrophotometry where the linearity range and percentage recoveries for DOM and CINN were 2.5-30 micro g mL(-1), 5-25 micro g mL(-1) and 100.06+/-1.157, 99.93+/-1.377, respectively. The second method depends on the application of partial least squares (PLS) and principle component regression (PCR) models. A training set consisting of 10 mixtures containing 5-20 micro g mL(-1) for each component was used for the construction of the PCR and PLS models. These models were used after their validation for the prediction of the concentration of DOM and CINN in their mixtures. The proposed procedures were successfully applied for the simultaneous determination of both drugs in laboratory prepared mixtures and in commercial tablet preparations. The validity of the proposed methods was assessed by applying the standard addition technique where the percentage recovery of the added standard was found to be 99.98+/-0.297 and 99.84+/-0.700 for DOM and CINN, respectively, using the derivative spectrophotometric method and 100.29+/-0.398 and 100.11+/-0.363 for DOM and CINN, respectively, using the PLS and PCR methods. The proposed procedures are rapid, simple, require no preliminary separation steps and can be used for routine analysis of both drugs in quality control laboratories.
Collapse
|
37
|
Simultaneous determination of domperidone maleate and cinnarizine in a binary mixture using derivative ratio spectrophotometry and classical least squares calibration. J Pharm Biomed Anal 2002; 30:21-33. [PMID: 12151062 DOI: 10.1016/s0731-7085(02)00094-8] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
This work is concerned with the simultaneous determination of domperidone maleate (DOM) and cinnarizine (CINN) in a binary mixture form without previous separation by two different methods. The first method is the application of derivative ratio spectrophotometry where the linearity range was 2.5-30 micro g/ml, 2.5-25 micro g/ml for DOM and CINN, respectively, and percentage recoveries were 100.26+/-1.308 and 99.86+/-0.939 for DOM and CINN, respectively, in their laboratory prepared mixtures. The second method depends on the application of classical least squares (CLS) calibration model. Two training sets were constructed and the best model was used for the prediction of the concentrations of both drugs. The proposed procedures were successfully applied for the simultaneous determination of both drugs in laboratory prepared mixtures and in commercial tablet preparations. The validity of the proposed methods was assessed by applying the standard addition technique where the percentage recovery of the added standard was found to be 99.83+/-1.861 and 98.38+/-0.871 for DOM and CINN, respectively, using the derivative ratio method and 99.53+/-0.916 and 99.39+/-0.599 for DOM and CINN, respectively, using the CLS method. The proposed procedures are rapid, simple, require no preliminary separation steps and can, therefore, be used routine analysis of both drugs in quality control laboratories.
Collapse
|
38
|
GC-MS determination of heroin metabolites in meconium: evaluation of four solid-phase extraction cartridges. J Anal Toxicol 2001; 25:93-8. [PMID: 11300513 DOI: 10.1093/jat/25.2.93] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
A procedure for extraction of heroin and metabolites for gas chromatography-mass spectrometry (GC-MS) analysis of meconium specimens that would allow detection of these analytes at low levels was needed. Solid-phase extraction (SPE) cartridges were therefore evaluated for their effectiveness in sample preparation. Four different types of commercially available extraction cartridges were used. Heroin, 6-monoacetylmorphine (6-MAM), morphine, and codeine were extracted from meconium samples using these SPE cartridges and then simultaneously analyzed using GC-MS. In each case, the extraction efficiency, linearity range, limit of detection (LOD), limit of quantitation (LOQ), between-run precision, and within-run precision were determined. Although satisfactory results were obtained with the four different types of SPE cartridges, best overall performance was observed using Clean Screen columns following the procedures outlined here. LODs as low as 20 ng/g for codeine, 10 ng/g for morphine, and 2.5 ng/g for 6-MAM were obtained, and LOQs as low as 20 ng/g for codeine, 10 ng/g for morphine, and 5 ng/g for 6-MAM were obtained. In all cases linearities were observed (r = > 0.99) for codeine, morphine, and 6-MAM over a wide concentration range (100-2000, 100-2000, and 5-100, respectively). At 50 ng/g codeine and morphine and 10 ng/g 6-MAM, the precision of analysis using these cartridges showed coefficients of variation ranging from 4.75% to 15.5%.
Collapse
|
39
|
Simultaneous analysis of delta9-THC and its major metabolites in urine, plasma, and meconium by GC-MS using an immunoaffinity extraction procedure. J Anal Toxicol 2000; 24:395-402. [PMID: 10999345 DOI: 10.1093/jat/24.6.395] [Citation(s) in RCA: 42] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
A simple extraction procedure for delta9-tetrahydrocannabinol (delta9-THC) and its metabolites from various biological specimens was developed based on immunoaffinity chromatography. Using the affinity resin prepared by immobilization of THC antibody onto cyanogen bromide-activated Sepharose 4B, delta9-THC and its major metabolites including 11-nor-delta9-THC-9-carboxylic acid (delta9-THCCOOH), 11-hydroxy-delta9-THC (11-OH-delta9-THC), and 8beta,11-dihydroxy-delta9-THC (8beta,11-diOH-delta9-THC) were extracted simultaneously from plasma or urine after enzyme hydrolysis. The samples were derivatized as TMS derivatives and analyzed by gas chromatography-mass spectrometry in EI mode with SIM monitoring. Greater than 87% extraction recovery of the four analytes was obtained from both plasma and urine at 5 and 50 ng/mL concentration levels. The method was also used for meconium analysis with some modification. The extraction recovery from meconium, however, was lower than that of plasma and urine, ranging from 52 to 72% at the 10-ng/g level. All compounds showed good linearity within the tested ranges up to 100 ng/mL (g). The limits of detection ranged from 0.5 to 2.5 ng/mL in plasma and urine, and from 1.0 to 2.5 ng/g in meconium. Analysis of 24 meconium specimens showed that 11-OH-delta9-THC is indeed an important metabolite in meconium.
Collapse
|