1
|
Pilot study: A simple CAD-based tool to detect breast cancer on MRI of the breast. Magn Reson Imaging 2024; 110:1-6. [PMID: 38479541 DOI: 10.1016/j.mri.2024.03.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Revised: 03/06/2024] [Accepted: 03/10/2024] [Indexed: 04/01/2024]
Abstract
PURPOSE This pilot-study aims to assess, whether quantitatively assessed enhancing breast tissue as a percentage of the entire breast volume can serve as an indicator of breast cancer at breast MRI and whether the contrast-agent employed affects diagnostic efficacy. MATERIALS This retrospective IRB-approved study, included 39 consecutive patients, that underwent two subsequent breast MRI exams for suspicious findings at conventional imaging with 0.1 mmol/kg gadobenic and gadoteric acid. Two independent readers, blinded to the histopathological outcome, assessed unenhanced and early post-contrast images using computer-assisted software (Brevis, Siemens Healthcare). Diagnostic performance was statistically determined for percentage of ipsilateral voxel volume enhancement and for percentage of contralateral enhancing voxel volume subtracted from ipsilateral enhancing voxel volume after crosstabulation with the dichotomized histological outcome (benign/malignant). RESULTS Ipsilateral enhancing voxel volume versus histopathological outcome resulted in an AUC of 0.707 and 0.687 for gadobenic acid, reader 1 and 2, respectively and in an AUC of 0.778 and 0.773 for gadoteric acid, reader 1 and 2, respectively. Accounting for background parenchymal enhancement by subtracting contralateral enhancing volume from ipsilateral enhancing voxel volume versus histolopathological outcome resulted in an AUC of 0.793 and 0.843 for gadobenic acid, reader 1 and 2, respectively and in an AUC of 0.692 and 0.662 for gadoteric acid, reader 1 and 2, respectively. Pairwise testing yielded no statistically significant difference both between readers and between contrast agents employed (p > 0.05). CONCLUSION Our proposed CAD algorithm, which quantitatively assesses enhancing breast tissue as a percentage of the entire breast volume, allows indicating the presence of breast cancer.
Collapse
|
2
|
ESR Essentials: screening for breast cancer - general recommendations by EUSOBI. Eur Radiol 2024:10.1007/s00330-024-10740-5. [PMID: 38656711 DOI: 10.1007/s00330-024-10740-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Revised: 02/13/2024] [Accepted: 02/17/2024] [Indexed: 04/26/2024]
Abstract
Breast cancer is the most frequently diagnosed cancer in women accounting for about 30% of all new cancer cases and the incidence is constantly increasing. Implementation of mammographic screening has contributed to a reduction in breast cancer mortality of at least 20% over the last 30 years. Screening programs usually include all women irrespective of their risk of developing breast cancer and with age being the only determining factor. This approach has some recognized limitations, including underdiagnosis, false positive cases, and overdiagnosis. Indeed, breast cancer remains a major cause of cancer-related deaths in women undergoing cancer screening. Supplemental imaging modalities, including digital breast tomosynthesis, ultrasound, breast MRI, and, more recently, contrast-enhanced mammography, are available and have already shown potential to further increase the diagnostic performances. Use of breast MRI is recommended in high-risk women and women with extremely dense breasts. Artificial intelligence has also shown promising results to support risk categorization and interval cancer reduction. The implementation of a risk-stratified approach instead of a "one-size-fits-all" approach may help to improve the benefit-to-harm ratio as well as the cost-effectiveness of breast cancer screening. KEY POINTS: Regular mammography should still be considered the mainstay of the breast cancer screening. High-risk women and women with extremely dense breast tissue should use MRI for supplemental screening or US if MRI is not available. Women need to participate actively in the decision to undergo personalized screening. KEY RECOMMENDATIONS: Mammography is an effective imaging tool to diagnose breast cancer in an early stage and to reduce breast cancer mortality (evidence level I). Until more evidence is available to move to a personalized approach, regular mammography should be considered the mainstay of the breast cancer screening. High-risk women should start screening earlier; first with yearly breast MRI which can be supplemented by yearly or biennial mammography starting at 35-40 years old (evidence level I). Breast MRI screening should be also offered to women with extremely dense breasts (evidence level I). If MRI is not available, ultrasound can be performed as an alternative, although the added value of supplemental ultrasound regarding cancer detection remains limited. Individual screening recommendations should be made through a shared decision-making process between women and physicians.
Collapse
|
3
|
How young radiologists use contrast media and manage adverse reactions: an international survey. Insights Imaging 2024; 15:92. [PMID: 38530547 DOI: 10.1186/s13244-024-01658-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2023] [Accepted: 02/25/2024] [Indexed: 03/28/2024] Open
Abstract
OBJECTIVES To collect real-world data about the knowledge and self-perception of young radiologists concerning the use of contrast media (CM) and the management of adverse drug reactions (ADR). METHODS A survey (29 questions) was distributed to residents and board-certified radiologists younger than 40 years to investigate the current international situation in young radiology community regarding CM and ADRs. Descriptive statistics analysis was performed. RESULTS Out of 454 respondents from 48 countries (mean age: 31.7 ± 4 years, range 25-39), 271 (59.7%) were radiology residents and 183 (40.3%) were board-certified radiologists. The majority (349, 76.5%) felt they were adequately informed regarding the use of CM. However, only 141 (31.1%) received specific training on the use of CM and 82 (18.1%) about management ADR during their residency. Although 266 (58.6%) knew safety protocols for handling ADR, 69.6% (316) lacked confidence in their ability to manage CM-induced ADRs and 95.8% (435) expressed a desire to enhance their understanding of CM use and handling of CM-induced ADRs. Nearly 300 respondents (297; 65.4%) were aware of the benefits of contrast-enhanced ultrasound, but 249 (54.8%) of participants did not perform it. The preferred CM injection strategy in CT parenchymal examination and CT angiography examination was based on patient's lean body weight in 318 (70.0%) and 160 (35.2%), a predeterminate fixed amount in 79 (17.4%) and 116 (25.6%), iodine delivery rate in 26 (5.7%) and 122 (26.9%), and scan time in 31 (6.8%) and 56 (12.3%), respectively. CONCLUSION Training in CM use and management ADR should be implemented in the training of radiology residents. CRITICAL RELEVANCE STATEMENT We highlight the need for improvement in the education of young radiologists regarding contrast media; more attention from residency programs and scientific societies should be focused on training about contrast media use and the management of adverse drug reactions. KEY POINTS • This survey investigated training of young radiologists about use of contrast media and management adverse reactions. • Most young radiologists claimed they did not receive dedicated training. • An extreme heterogeneity of responses was observed about contrast media indications/contraindications and injection strategy.
Collapse
|
4
|
A spiculated mass target model for clinical image quality control in digital mammography. Br J Radiol 2024; 97:560-566. [PMID: 38265303 DOI: 10.1093/bjr/tqad055] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Revised: 11/16/2023] [Accepted: 12/04/2023] [Indexed: 01/25/2024] Open
Abstract
OBJECTIVES Quality assurance of breast imaging has a long history of using test objects to optimize and follow up imaging devices. In particular, the evaluation of new techniques benefits from suitable test objects. The applicability of a phantom consisting of spiculated masses to assess image quality and its dependence on dose in flat field digital mammography (FFDM) and digital breast tomosynthesis systems (DBT) is investigated. METHODS Two spiculated masses in five different sizes each were created from a database of clinical tumour models. The masses were produced using 3D printing and embedded into a cuboid phantom. Image quality is determined by the number of spicules identified by human observers. RESULTS The results suggest that the effect of dose on spicule detection is limited especially in cases with smaller objects and probably hidden by the inter-reader variability. Here, an average relative inter-reader variation of the counted number of 31% was found (maximum 83%). The mean relative intra-reader variability was found to be 17%. In DBT, sufficiently good results were obtained only for the largest masses. CONCLUSIONS It is possible to integrate spiculated masses into a cuboid phantom. It is easy to print and should allow a direct and prompt evaluation of the quality status of the device by counting visible spicules. Human readout presented the major uncertainty in this study, indicating that automated readout may improve the reproducibility and consistency of the results considerably. ADVANCES IN KNOWLEDGE A cuboid phantom including clinical objects as spiculated lesion models for visual assessing the image quality in FFDM and DBT was developed and is introduced in this work. The evaluation of image quality works best with the two larger masses with 21 spicules.
Collapse
|
5
|
MRI Insights in Breast Imaging. Curr Med Imaging 2024; 20:CMIR-EPUB-138778. [PMID: 38415477 DOI: 10.2174/0115734056274670240205090722] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2023] [Revised: 11/17/2023] [Accepted: 12/22/2023] [Indexed: 02/29/2024]
Abstract
In the world, breast cancer is the most commonly diagnosed cancer among women. Currently, MRI is the most sensitive breast imaging method for detecting breast cancer, although false positive rates are still an issue. To date, the accuracy of breast MRI is widely recognized across various clinical scenarios, in particular, staging of known cancer, screening for breast cancer in high-risk women, and evaluation of response to neoadjuvant chemotherapy. Since technical development and further clinical indications have expanded over recent years, dedicated breast radiologists need to constantly update their knowledge and expertise to remain confident and maintain high levels of diagnostic performance in breast MRI. This review aims to detail current and future applications of breast MRI, from technological requirements and advances to new multiparametric and abbreviated protocols, and ultrafast imaging, as well as current and future indications.
Collapse
|
6
|
Contrast-enhanced breast imaging: Current status and future challenges. Eur J Radiol 2024; 171:111312. [PMID: 38237520 DOI: 10.1016/j.ejrad.2024.111312] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Revised: 01/04/2024] [Accepted: 01/09/2024] [Indexed: 02/10/2024]
Abstract
BACKGROUND Contrast-enhanced breast MRI and recently also contrast-enhanced mammography (CEM) are available for breast imaging. The aim of the current overview is to explore existing evidence and ongoing challenges of contrast-enhanced breast imaging. METHODS This narrative provides an introduction to the contrast-enhanced breast imaging modalities breast MRI and CEM. Underlying principle, techniques and BI-RADS reporting of both techniques are described and compared, and the following indications and ongoing challenges are discussed: problem-solving, high-risk screening, supplemental screening in women with extremely dense breast tissue, breast implants, neoadjuvant systemic therapy (NST) response monitoring, MRI-guided and CEM- guided biopsy. RESULTS Technique and reporting for breast MRI are standardised, for the newer CEM standardisation is in progress. Similarly, compared to other modalities, breast MRI is well established as superior for problem-solving, screening women at high risk, screening women with extremely dense breast tissue or with implants; and for monitoring response to NST. Furthermore, MRI-guided biopsy is a reliable technique with low long-term false negative rates. For CEM, data is as yet either absent or limited, but existing results in these settings are promising. CONCLUSION Contrast-enhanced breast imaging achieves highest diagnostic performance and should be considered essential. Of the two contrast-enhanced modalities, evidence of breast MRI superiority is ample, and preliminary results on CEM are promising, yet CEM warrants further study.
Collapse
|
7
|
Automated analysis of the total choline resonance peak in breast proton magnetic resonance spectroscopy. NMR IN BIOMEDICINE 2024; 37:e5054. [PMID: 37794648 DOI: 10.1002/nbm.5054] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Revised: 09/08/2023] [Accepted: 09/11/2023] [Indexed: 10/06/2023]
Abstract
The aim of the current study was to compare the performance of fully automated software with human expert interpretation of single-voxel proton magnetic resonance spectroscopy (1H-MRS) spectra in the assessment of breast lesions. Breast magnetic resonance imaging (MRI) (including contrast-enhanced T1-weighted, T2-weighted, and diffusion-weighted imaging) and 1H-MRS images of 74 consecutive patients were acquired on a 3-T positron emission tomography-MRI scanner then automatically imported into and analyzed by SpecTec-ULR 1.1 software (LifeTec Solutions GmbH). All ensuing 117 spectra were additionally independently analyzed and interpreted by two blinded radiologists. Histopathology of at least 24 months of imaging follow-up served as the reference standard. Nonparametric Spearman's correlation coefficients for all measured parameters (signal-to-noise ratio [SNR] and integral of total choline [tCho]), Passing and Bablok regression, and receiver operating characteristic analysis, were calculated to assess test diagnostic performance, as well as to compare automated with manual reading. Based on 117 spectra of 74 patients, the area under the curve for tCho SNR and integrals ranged from 0.768 to 0.814 and from 0.721 to 0.784 to distinguish benign from malignant tissue, respectively. Neither method displayed significant differences between measurements (automated vs. human expert readers, p > 0.05), in line with the results from the univariate Spearman's rank correlation coefficients, as well as the Passing and Bablok regression analysis. It was concluded that this pilot study demonstrates that 1H-MRS data from breast MRI can be automatically exported and interpreted by SpecTec-ULR 1.1 software. The diagnostic performance of this software was not inferior to human expert readers.
Collapse
|
8
|
Current use and future perspectives of contrast-enhanced mammography (CEM): a survey by the European Society of Breast Imaging (EUSOBI). Eur Radiol 2024:10.1007/s00330-023-10574-7. [PMID: 38227202 DOI: 10.1007/s00330-023-10574-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2023] [Revised: 12/08/2023] [Accepted: 12/16/2023] [Indexed: 01/17/2024]
Abstract
OBJECTIVES To perform a survey among members of the European Society of Breast Imaging (EUSOBI) regarding the use of contrast-enhanced mammography (CEM). METHODS A panel of nine board-certified radiologists developed a 29-item online questionnaire, distributed to all EUSOBI members (inside and outside Europe) from January 25 to March 10, 2023. CEM implementation, examination protocols, reporting strategies, and current and future CEM indications were investigated. Replies were exploratively analyzed with descriptive and non-parametric statistics. RESULTS Among 434 respondents (74.9% from Europe), 50% (217/434) declared to use CEM, 155/217 (71.4%) seeing less than 200 CEMs per year. CEM use was associated with academic settings and high breast imaging workload (p < 0.001). The lack of CEM adoption was most commonly due to the perceived absence of a clinical need (65.0%) and the lack of resources to acquire CEM-capable systems (37.3%). CEM protocols varied widely, but most respondents (61.3%) had already adopted the 2022 ACR CEM BI-RADS® lexicon. CEM use in patients with contraindications to MRI was the most common current indication (80.6%), followed by preoperative staging (68.7%). Patients with MRI contraindications also represented the most commonly foreseen CEM indication (88.0%), followed by the work-up of inconclusive findings at non-contrast examinations (61.5%) and supplemental imaging in dense breasts (53.0%). Respondents declaring CEM use and higher CEM experience gave significantly more current (p = 0.004) and future indications (p < 0.001). CONCLUSIONS Despite a trend towards academic high-workload settings and its prevalent use in patients with MRI contraindications, CEM use and progressive experience were associated with increased confidence in the technique. CLINICAL RELEVANCE STATEMENT In this first survey on contrast-enhanced mammography (CEM) use and perspectives among the European Society of Breast Imaging (EUSOBI) members, the perceived absence of a clinical need chiefly drove the 50% CEM adoption rate. CEM adoption and progressive experience were associated with more extended current and future indications. KEY POINTS • Among the 434 members of the European Society of Breast Imaging who completed this survey, 50% declared to use contrast-enhanced mammography in clinical practice. • Due to the perceived absence of a clinical need, contrast-enhanced mammography (CEM) is still prevalently used as a replacement for MRI in patients with MRI contraindications. • The number of current and future CEM indications marked by respondents was associated with their degree of CEM experience.
Collapse
|
9
|
Using the Kaiser Score as a clinical decision rule for breast lesion classification: Does computer-assisted curve type analysis improve diagnosis? Eur J Radiol 2024; 170:111271. [PMID: 38185026 DOI: 10.1016/j.ejrad.2023.111271] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Revised: 12/12/2023] [Accepted: 12/14/2023] [Indexed: 01/09/2024]
Abstract
PURPOSE We aimed to investigate the effect of using visual or automatic enhancement curve type assessment on the diagnostic performance of the Kaiser Score (KS), a clinical decision rule for breast MRI. METHOD This IRB-approved retrospective study analyzed consecutive conventional BI-RADS 0, 4 or 5 patients who underwent biopsy after 1.5T breast MRI according to EUSOBI recommendations between 2013 and 2015. The KS includes five criteria (spiculations; signal intensity (SI)-time curve type; margins of the lesion; internal enhancement; and presence of edema) resulting in scores from 1 (=lowest) to 11 (=highest risk of breast cancer). Enhancement curve types (Persistent, Plateau or Wash-out) were assessed by two radiologists independently visually and using a pixel-wise color-coded computed parametric map of curve types. KS diagnostic performance differences between readings were compared by ROC analysis. RESULTS In total 220 lesions (147 benign, 73 malignant) including mass (n = 148) and non-mass lesions (n = 72) were analyzed. KS reading performance in distinguishing benign from malignant lesions did not differ between visual analysis and parametric map (P = 0.119; visual: AUC 0.875, sensitivity 95 %, specificity 63 %; and map: AUC 0.901, sensitivity 97 %, specificity 65 %). Additionally, analyzing mass and non-mass lesions separately, showed no difference between parametric map based and visual curve type-based KS analysis as well (P = 0.130 and P = 0.787). CONCLUSIONS The performance of the Kaiser Score is largely independent of the curve type assessment methodology, confirming its robustness as a clinical decision rule for breast MRI in any type of breast lesion in clinical routine.
Collapse
|
10
|
Added value of clinical decision rules for the management of enhancing breast MRI lesions: A systematic comparison of the Kaiser score and the Göttingen score. Eur J Radiol 2023; 169:111185. [PMID: 37939606 DOI: 10.1016/j.ejrad.2023.111185] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2023] [Revised: 10/16/2023] [Accepted: 11/02/2023] [Indexed: 11/10/2023]
Abstract
PURPOSE We investigated the added value of two internationally used clinical decision rules in the management of enhancing lesions on breast MRI. METHODS This retrospective, institutional review board approved study included consecutive patients from two different populations. Patients received breast MRI according to the recommendations of the European Society of Breast Imaging (EUSOBI). Initially, all examinations were assessed by expert readers without using clinical decision rules. All lesions rated as category 4 or 5 according to the Breast Imaging Reporting and Data System were histologically confirmed. These lesions were re-evaluated by an expert reader blinded to the histology. He assigned each lesion a Göttingen score (GS) and a Kaiser score (KS) on different occasions. To provide an estimate on inter-reader agreement, a second fellowship-trained reader assessed a subset of these lesions. Subgroup analyses based on lesion type (mass vs. non-mass), size (>1 cm vs. ≤ 1 cm), menopausal status, and significant background parenchymal enhancement were conducted. The areas under the ROC curves (AUCs) for the GS and KS were compared, and the potential to avoid unnecessary biopsies was determined according to previously established cutoffs (KS > 4, GS > 3) RESULTS: 527 lesions in 506 patients were included (mean age: 51.8 years, inter-quartile-range: 43.0-61.0 years). 131/527 lesions were malignant (24.9 %; 95 %-confidence-interval: 21.3-28.8). In all subgroups, the AUCs of the KS (median = 0.91) were higher than those of the GS (median = 0.83). Except for "premenopausal patients" (p = 0.057), these differences were statistically significant (p ≤ 0.01). Kappa agreement was higher for the KS (0.922) than for the GS (0.358). CONCLUSION Both the KS and the GS provided added value for the management of enhancing lesions on breast MRI. The KS was superior to the GS in terms of avoiding unnecessary biopsies and showed superior inter-reader agreement; therefore, it may be regarded as the clinical decision rule of choice.
Collapse
|
11
|
Estimation of the biomechanical mammographic deformation of the breast using machine learning models. Clin Biomech (Bristol, Avon) 2023; 110:106117. [PMID: 37826970 DOI: 10.1016/j.clinbiomech.2023.106117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Revised: 09/07/2023] [Accepted: 09/27/2023] [Indexed: 10/14/2023]
Abstract
BACKGROUND A typical problem in the registration of MRI and X-ray mammography is the nonlinear deformation applied to the breast during mammography. We have developed a method for virtual deformation of the breast using a biomechanical model automatically constructed from MRI. The virtual deformation is applied in two steps: unloaded state estimation and compression simulation. The finite element method is used to solve the deformation process. However, the extensive computational cost prevents its usage in clinical routine. METHODS We propose three machine learning models to overcome this problem: an extremely randomized tree (first model), extreme gradient boosting (second model), and deep learning-based bidirectional long short-term memory with an attention layer (third model) to predict the deformation of a biomechanical model. We evaluated our methods with 516 breasts with realistic compression ratios up to 76%. FINDINGS We first applied one-fold validation, in which the second and third models performed better than the first model. We then applied ten-fold validation. For the unloaded state estimation, the median RMSE for the second and third models is 0.8 mm and 1.2 mm, respectively. For the compression, the median RMSE is 3.4 mm for both models. We evaluated correlations between model accuracy and characteristics of the clinical datasets such as compression ratio, breast volume, and tissue types. INTERPRETATION Using the proposed models, we achieved accurate results comparable to the finite element model, with a speedup of factor 240 using the extreme gradient boosting model. These proposed models can replace the finite element model simulation, enabling clinically relevant real-time application.
Collapse
|
12
|
Image quality of DWI at breast MRI depends on the amount of fibroglandular tissue: implications for unenhanced screening. Eur Radiol 2023:10.1007/s00330-023-10321-y. [PMID: 38008743 DOI: 10.1007/s00330-023-10321-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Revised: 06/29/2023] [Accepted: 07/05/2023] [Indexed: 11/28/2023]
Abstract
OBJECTIVES To compare image quality of diffusion-weighted imaging (DWI) and contrast-enhanced breast MRI (DCE-T1) stratified by the amount of fibroglandular tissue (FGT) as a measure of breast density. METHODS Retrospective, multi-reader, bicentric visual grading analysis study on breast density (A-D) and overall image and fat suppression quality of DWI and DCE-T1, scored on a standard 5-point Likert scale. Cross tabulations and visual grading characteristic (VGC) curves were calculated for fatty breasts (A/B) versus dense breasts (C/D). RESULTS Image quality of DWI was higher in the case of increased breast density, with good scores (score 3-5) in 85.9% (D) and 88.4% (C), compared to 61.6% (B) and 53.5% (A). Overall image quality of DWI was in favor of dense breasts (C/D), with an area under the VGC curve of 0.659 (p < 0.001). Quality of DWI and DCE-T1 fat suppression increased with higher breast density, with good scores (score 3-5) for 86.9% and 45.7% of density D, and 90.2% and 42.9% of density C cases, compared to 76.0% and 33.6% for density B and 54.7% and 29.6% for density A (DWI and DCE-T1 respectively). CONCLUSIONS Dense breasts show excellent fat suppression and substantially higher image quality in DWI images compared with non-dense breasts. These results support the setup of studies exploring DWI-based MR imaging without IV contrast for additional screening of women with dense breasts. CLINICAL RELEVANCE STATEMENT Our findings demonstrate that image quality of DWI is robust in women with an increased amount of fibroglandular tissue, technically supporting the feasibility of exploring applications such as screening of women with mammographically dense breasts. KEY POINTS • Image and fat suppression quality of diffusion-weighted imaging are dependent on the amount of fibroglandular tissue (FGT) which is closely connected to breast density. • Fat suppression quality in diffusion-weighted imaging of the breast is best in women with a high amount of fibroglandular tissue. • High image quality of diffusion-weighted imaging in women with a high amount of FGT in MRI supports that the technical feasibility of DWI can be explored in the additional screening of women with mammographically dense breasts.
Collapse
|
13
|
Preoperative breast MRI positively impacts surgical outcomes of needle biopsy-diagnosed pure DCIS: a patient-matched analysis from the MIPA study. Eur Radiol 2023:10.1007/s00330-023-10409-5. [PMID: 37999727 DOI: 10.1007/s00330-023-10409-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2023] [Revised: 09/16/2023] [Accepted: 10/11/2023] [Indexed: 11/25/2023]
Abstract
OBJECTIVES To investigate the influence of preoperative breast MRI on mastectomy and reoperation rates in patients with pure ductal carcinoma in situ (DCIS). METHODS The MIPA observational study database (7245 patients) was searched for patients aged 18-80 years with pure unilateral DCIS diagnosed at core needle or vacuum-assisted biopsy (CNB/VAB) and planned for primary surgery. Patients who underwent preoperative MRI (MRI group) were matched (1:1) to those who did not receive MRI (noMRI group) according to 8 confounding covariates that drive referral to MRI (age; hormonal status; familial risk; posterior-to-nipple diameter; BI-RADS category; lesion diameter; lesion presentation; surgical planning at conventional imaging). Surgical outcomes were compared between the matched groups with nonparametric statistics after calculating odds ratios (ORs). RESULTS Of 1005 women with pure unilateral DCIS at CNB/VAB (507 MRI group, 498 noMRI group), 309 remained in each group after matching. First-line mastectomy rate in the MRI group was 20.1% (62/309 patients, OR 2.03) compared to 11.0% in the noMRI group (34/309 patients, p = 0.003). The reoperation rate was 10.0% in the MRI group (31/309, OR for reoperation 0.40) and 22.0% in the noMRI group (68/309, p < 0.001), with a 2.53 OR of avoiding reoperation in the MRI group. The overall mastectomy rate was 23.3% in the MRI group (72/309, OR 1.40) and 17.8% in the noMRI group (55/309, p = 0.111). CONCLUSIONS Compared to those going directly to surgery, patients with pure DCIS at CNB/VAB who underwent preoperative MRI had a higher OR for first-line mastectomy but a substantially lower OR for reoperation. CLINICAL RELEVANCE STATEMENT When confounding factors behind MRI referral are accounted for in the comparison of patients with CNB/VAB-diagnosed pure unilateral DCIS, preoperative MRI yields a reduction of reoperations that is more than twice as high as the increase in overall mastectomies. KEY POINTS • Confounding factors cause imbalance when investigating the influence of preoperative MRI on surgical outcomes of pure DCIS. • When patient matching is applied to women with pure unilateral DCIS, reoperation rates are significantly reduced in women who underwent preoperative MRI. • The reduction of reoperations brought about by preoperative MRI is more than double the increase in overall mastectomies.
Collapse
|
14
|
A survey by the European Society of Breast Imaging on radiologists' preferences regarding quality assurance measures of image interpretation in screening and diagnostic mammography. Eur Radiol 2023; 33:8103-8111. [PMID: 37481690 PMCID: PMC10598074 DOI: 10.1007/s00330-023-09973-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/24/2023]
Abstract
OBJECTIVES Quality assurance (QA) of image interpretation plays a key role in screening and diagnostic mammography, maintaining minimum standards and supporting continuous improvement in interpreting images. However, the QA structure across Europe shows considerable variation. The European Society of Breast Imaging (EUSOBI) conducted a survey among the members to collect information on radiologists' preferences regarding QA measures in mammography. MATERIALS AND METHODS An anonymous online survey consisting of 25 questions was distributed to all EUSOBI members and national breast radiology bodies in Europe. The questions were designed to collect demographic characteristics, information on responders' mammography workload and data about QA measures currently used in their country. Data was analysed using descriptive statistical analysis, the χ2 test, linear regression, and Durbin-Watson statistic test. RESULTS In total, 251 breast radiologists from 34 countries completed the survey. Most respondents were providing both screening and symptomatic services (137/251, 54.6%), working in an academic hospital (85/251, 33.9%) and reading 1000-4999 cases per year (109/251, 43.4%). More than half of them (133/251, 53%) had established QA measures in their workplace. Although less than one-third (71/251, 28.3%) had to participate in regular performance testing, the vast majority (190/251, 75.7%) agreed that a mandatory test would be helpful to improve their skills. CONCLUSION QA measures were in place for more than half of the respondents working in screening and diagnostic mammography to evaluate their breast imaging performance. Although there were substantial differences between countries, the importance of having QA in the workplace and implemented was widely acknowledged by radiologists. CLINICAL RELEVANCE STATEMENT Although several quality assurance (QA) measures of image interpretation are recommended by European bodies or national organisations, the QA in mammography is quite heterogenous between countries and reporting settings, and not always actively implemented across Europe. KEY POINTS The first survey that presents radiologists' preferences regarding QA measures of image interpretation in mammography. Quality assurance measures in the workplace are better-established for breast screening compared to diagnostic mammography. Radiologists consider that performance tests would help to improve their mammography interpretation skills.
Collapse
|
15
|
Panoramic Magnetic Resonance Imaging of the Breast With a Wearable Coil Vest. Invest Radiol 2023; 58:799-810. [PMID: 37227137 PMCID: PMC10581436 DOI: 10.1097/rli.0000000000000991] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Accepted: 04/21/2023] [Indexed: 05/26/2023]
Abstract
BACKGROUND Breast cancer, the most common malignant cancer in women worldwide, is typically diagnosed by x-ray mammography, which is an unpleasant procedure, has low sensitivity in women with dense breasts, and involves ionizing radiation. Breast magnetic resonance imaging (MRI) is the most sensitive imaging modality and works without ionizing radiation, but is currently constrained to the prone imaging position due to suboptimal hardware, therefore hampering the clinical workflow. OBJECTIVES The aim of this work is to improve image quality in breast MRI, to simplify the clinical workflow, shorten measurement time, and achieve consistency in breast shape with other procedures such as ultrasound, surgery, and radiation therapy. MATERIALS AND METHODS To this end, we propose "panoramic breast MRI"-an approach combining a wearable radiofrequency coil for 3 T breast MRI (the "BraCoil"), acquisition in the supine position, and a panoramic visualization of the images. We demonstrate the potential of panoramic breast MRI in a pilot study on 12 healthy volunteers and 1 patient, and compare it to the state of the art. RESULTS With the BraCoil, we demonstrate up to 3-fold signal-to-noise ratio compared with clinical standard coils and acceleration factors up to 6 × 4. Panoramic visualization of supine breast images reduces the number of slices to be viewed by a factor of 2-4. CONCLUSIONS Panoramic breast MRI allows for high-quality diagnostic imaging and facilitated correlation to other diagnostic and interventional procedures. The developed wearable radiofrequency coil in combination with dedicated image processing has the potential to improve patient comfort while enabling more time-efficient breast MRI compared with clinical coils.
Collapse
|
16
|
Simultaneous 18F-FDG PET/MRI Radiomics and Machine Learning Analysis of the Primary Breast Tumor for the Preoperative Prediction of Axillary Lymph Node Status in Breast Cancer. Cancers (Basel) 2023; 15:5088. [PMID: 37894455 PMCID: PMC10604950 DOI: 10.3390/cancers15205088] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Revised: 10/08/2023] [Accepted: 10/17/2023] [Indexed: 10/29/2023] Open
Abstract
In this prospective study, 117 female patients (mean age = 53 years) with 127 histologically proven breast cancer lesions (lymph node (LN) positive = 85, LN negative = 42) underwent simultaneous 18F-FDG PET/MRI of the breast. Quantitative parameters were calculated from dynamic contrast-enhanced (DCE) imaging (tumor Mean Transit Time, Volume Distribution, Plasma Flow), diffusion-weighted imaging (DWI) (tumor ADCmean), and PET (tumor SUVmax, mean and minimum, SUVmean of ipsilateral breast parenchyma). Manual whole-lesion segmentation was also performed on DCE, T2-weighted, DWI, and PET images, and radiomic features were extracted. The dataset was divided into a training (70%) and a test set (30%). Multi-step feature selection was performed, and a support vector machine classifier was trained and tested for predicting axillary LN status. 13 radiomic features from DCE, DWI, T2-weighted, and PET images were selected for model building. The classifier obtained an accuracy of 79.8 (AUC = 0.798) in the training set and 78.6% (AUC = 0.839), with sensitivity and specificity of 67.9% and 100%, respectively, in the test set. A machine learning-based radiomics model comprising 18F-FDG PET/MRI radiomic features extracted from the primary breast cancer lesions allows high accuracy in non-invasive identification of axillary LN metastasis.
Collapse
|
17
|
Screening and diagnostic breast MRI: how do they impact surgical treatment? Insights from the MIPA study. Eur Radiol 2023; 33:6213-6225. [PMID: 37138190 PMCID: PMC10415233 DOI: 10.1007/s00330-023-09600-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2022] [Revised: 01/19/2023] [Accepted: 02/22/2023] [Indexed: 05/05/2023]
Abstract
OBJECTIVES To report mastectomy and reoperation rates in women who had breast MRI for screening (S-MRI subgroup) or diagnostic (D-MRI subgroup) purposes, using multivariable analysis for investigating the role of MRI referral/nonreferral and other covariates in driving surgical outcomes. METHODS The MIPA observational study enrolled women aged 18-80 years with newly diagnosed breast cancer destined to have surgery as the primary treatment, in 27 centres worldwide. Mastectomy and reoperation rates were compared using non-parametric tests and multivariable analysis. RESULTS A total of 5828 patients entered analysis, 2763 (47.4%) did not undergo MRI (noMRI subgroup) and 3065 underwent MRI (52.6%); of the latter, 2441/3065 (79.7%) underwent MRI with preoperative intent (P-MRI subgroup), 510/3065 (16.6%) D-MRI, and 114/3065 S-MRI (3.7%). The reoperation rate was 10.5% for S-MRI, 8.2% for D-MRI, and 8.5% for P-MRI, while it was 11.7% for noMRI (p ≤ 0.023 for comparisons with D-MRI and P-MRI). The overall mastectomy rate (first-line mastectomy plus conversions from conserving surgery to mastectomy) was 39.5% for S-MRI, 36.2% for P-MRI, 24.1% for D-MRI, and 18.0% for noMRI. At multivariable analysis, using noMRI as reference, the odds ratios for overall mastectomy were 2.4 (p < 0.001) for S-MRI, 1.0 (p = 0.957) for D-MRI, and 1.9 (p < 0.001) for P-MRI. CONCLUSIONS Patients from the D-MRI subgroup had the lowest overall mastectomy rate (24.1%) among MRI subgroups and the lowest reoperation rate (8.2%) together with P-MRI (8.5%). This analysis offers an insight into how the initial indication for MRI affects the subsequent surgical treatment of breast cancer. KEY POINTS • Of 3065 breast MRI examinations, 79.7% were performed with preoperative intent (P-MRI), 16.6% were diagnostic (D-MRI), and 3.7% were screening (S-MRI) examinations. • The D-MRI subgroup had the lowest mastectomy rate (24.1%) among MRI subgroups and the lowest reoperation rate (8.2%) together with P-MRI (8.5%). • The S-MRI subgroup had the highest mastectomy rate (39.5%) which aligns with higher-than-average risk in this subgroup, with a reoperation rate (10.5%) not significantly different to that of all other subgroups.
Collapse
|
18
|
Introduction of a breast apparent diffusion coefficient category system (ADC-B) derived from a large multicenter MRI database. Eur Radiol 2023; 33:5400-5410. [PMID: 37166495 PMCID: PMC10326122 DOI: 10.1007/s00330-023-09675-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2022] [Revised: 02/27/2023] [Accepted: 03/14/2023] [Indexed: 05/12/2023]
Abstract
OBJECTIVES To develop an intuitive and generally applicable system for the reporting, assessment, and documentation of ADC to complement standard BI-RADS criteria. METHODS This was a multicentric, retrospective analysis of 11 independently conducted institutional review board-approved studies from seven institutions performed between 2007 and 2019. Breast Apparent Diffusion coefficient (ADC-B) categories comprised ADC-B0 (ADC non-diagnostic), ADC-B1 (no enhancing lesion), and ADC-B2-5. The latter was defined by plotting ADC versus cumulative malignancy rates. Statistics comprised ANOVA with post hoc testing and ROC analysis. p values ≤ 0.05 were considered statistically significant. RESULTS A total of 1625 patients (age: 55.9 years (± 13.8)) with 1736 pathologically verified breast lesions were included. The mean ADC (× 10-3 mm2/s) differed significantly between benign (1.45, SD .40) and malignant lesions (.95, SD .39), and between invasive (.92, SD .22) and in situ carcinomas (1.18, SD .30) (p < .001). The following ADC-B categories were identified: ADC-B0-ADC cannot be assessed; ADC-B1-no contrast-enhancing lesion; ADC-B2-ADC ≥ 1.9 (cumulative malignancy rate < 0.1%); ADC-B3-ADC 1.5 to < 1.9 (0.1-1.7%); ADC-B4-ADC 1.0 to < 1.5 (10-24.5%); and ADC-B5-ADC < 1.0 (> 24.5%). At the latter threshold, a positive predictive value of 95.8% (95% CI 0.94-0.97) for invasive versus non-invasive breast carcinomas was reached. CONCLUSIONS The breast apparent diffusion coefficient system (ADC-B) provides a simple and widely applicable categorization scheme for assessment, documentation, and reporting of apparent diffusion coefficient values in contrast-enhancing breast lesions on MRI. CLINICAL RELEVANCE STATEMENT The ADC-B system, based on diverse MRI examinations, is clinically relevant for stratifying breast cancer risk via apparent diffusion coefficient measurements, and complements BI-RADS for improved clinical decision-making and patient outcomes. KEY POINTS • The breast apparent diffusion coefficient category system (ADC-B) is a simple tool for the assessment, documentation, and reporting of ADC values in contrast-enhancing breast lesions on MRI. • The categories comprise ADC-B0 for non-diagnostic examinations, ADC-B1 for examinations without an enhancing lesion, and ADC-B2-5 for enhancing lesions with an increasing malignancy rate. • The breast apparent diffusion coefficient category system may be used to complement BI-RADS in clinical decision-making.
Collapse
|
19
|
European Society of Breast Imaging (EUSOBI) guidelines on the management of axillary lymphadenopathy after COVID-19 vaccination: 2023 revision. Insights Imaging 2023; 14:126. [PMID: 37466753 DOI: 10.1186/s13244-023-01453-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Accepted: 05/14/2023] [Indexed: 07/20/2023] Open
Abstract
Axillary lymphadenopathy is a common side effect of COVID-19 vaccination, leading to increased imaging-detected asymptomatic and symptomatic unilateral axillary lymphadenopathy. This has threatened to negatively impact the workflow of breast imaging services, leading to the release of ten recommendations by the European Society of Breast Imaging (EUSOBI) in August 2021. Considering the rapidly changing scenario and data scarcity, these initial recommendations kept a highly conservative approach. As of 2023, according to newly acquired evidence, EUSOBI proposes the following updates, in order to reduce unnecessary examinations and avoid delaying necessary examinations. First, recommendation n. 3 has been revised to state that breast examinations should not be delayed or rescheduled because of COVID-19 vaccination, as evidence from the first pandemic waves highlights how delayed or missed screening tests have a negative effect on breast cancer morbidity and mortality, and that there is a near-zero risk of subsequent malignant findings in asymptomatic patients who have unilateral lymphadenopathy and no suspicious breast findings. Second, recommendation n. 7 has been revised to simplify follow-up strategies: in patients without breast cancer history and no imaging findings suspicious for cancer, symptomatic and asymptomatic imaging-detected unilateral lymphadenopathy on the same side of recent COVID-19 vaccination (within 12 weeks) should be classified as a benign finding (BI-RADS 2) and no further work-up should be pursued. All other recommendations issued by EUSOBI in 2021 remain valid.
Collapse
|
20
|
Prospective validation of 18F-Fluoroethylcholine as a tracer in PET/MRI for the evaluation of breast lesions and prediction of lymph node status. LA RADIOLOGIA MEDICA 2023:10.1007/s11547-023-01633-6. [PMID: 37221356 DOI: 10.1007/s11547-023-01633-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Accepted: 04/19/2023] [Indexed: 05/25/2023]
Abstract
PURPOSE To assess 18F-Fluoroethylcholine (18F-FEC) as a PET/MRI tracer in the evaluation of breast lesions, breast cancer aggressiveness, and prediction of lymph node status. MATERIALS AND METHODS This prospective, monocentric study was approved by the ethics committee and patients gave written, informed consent. This clinical trial was registered in the EudraCT database (Number 2017-003089-29). Women who presented with suspicious breast lesions were included. Histopathology was used as reference standard. Simultaneous 18F-FEC PET/MRI of the breast was performed in a prone position with a dedicated breast coil. MRI was performed using a standard protocol before and after contrast agent administration. A simultaneous read by nuclear medicine physicians and radiologists collected the imaging data of MRI-detected lesions, including the maximum standardized 18F-FEC-uptake value of breast lesions (SUVmaxT) and axillary lymph nodes (SUVmaxLN). Differences in SUVmax were evaluated with the Mann-Whitney U test. To calculate diagnostic performance, the area under the receiver operating characteristics curve (ROC) was used. RESULTS There were 101 patients (mean age 52.3 years, standard deviation 12.0) with 117 breast lesions included (30 benign, 7 ductal carcinomas in situ, 80 invasive carcinomas). 18F-FEC was well tolerated by all patients. The ROC to distinguish benign from malignant breast lesions was 0.846. SUVmaxT was higher if lesions were malignant (p < 0.001), had a higher proliferation rate (p = 0.011), and were HER2-positive (p = 0.041). SUVmaxLN was higher in metastatic lymph nodes, with an ROC of 0.761 for SUVmaxT and of 0.793 for SUVmaxLN. CONCLUSION: Simultaneous 18F-FEC PET/MRI is safe and has the potential to be used for the evaluation of breast cancer aggressiveness, and prediction of lymph node status.
Collapse
|
21
|
Image-Guided Localization Techniques for Metastatic Axillary Lymph Nodes in Breast Cancer; What Radiologists Should Know. Cancers (Basel) 2023; 15:cancers15072130. [PMID: 37046791 PMCID: PMC10093304 DOI: 10.3390/cancers15072130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 03/31/2023] [Accepted: 03/31/2023] [Indexed: 04/14/2023] Open
Abstract
Targeted axillary dissection (TAD) is an axillary staging technique after NACT that involves the removal of biopsy-proven metastatic lymph nodes in addition to sentinel lymph node biopsy (SLNB). This technique avoids the morbidity of traditional axillary lymph node dissection and has shown a lower false-negative rate than SLNB alone. Therefore, marking positive axillary lymph nodes before NACT is critical in order to locate and remove them in the subsequent surgery. Current localization methods include clip placement with intraoperative ultrasound, carbon-suspension liquids, localization wires, radioactive tracer-based localizers, magnetic seeds, radar reflectors, and radiofrequency identification devices. The aim of this paper is to illustrate the management of axillary lymph nodes based on current guidelines and explain the features of axillary lymph node markers, with relative advantages and disadvantages.
Collapse
|
22
|
Residual fibroglandular breast tissue after mastectomy is associated with an increased risk of a local recurrence or a new primary breast cancer". BMC Cancer 2023; 23:281. [PMID: 36978031 PMCID: PMC10044359 DOI: 10.1186/s12885-023-10764-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2022] [Accepted: 03/22/2023] [Indexed: 03/30/2023] Open
Abstract
BACKGROUND Residual fibroglandular breast tissue (RFGT) following a mastectomy has been claimed to be associated with the occurrence of an in-breast local recurrence (IBLR) or new primary tumor (NP). Yet, scientific evidence proving this assumption is lacking. The primary aim of the study was to verify whether RFGT following a mastectomy is a risk factor for an IBLR or NP. METHODS This retrospective analysis included all patients that underwent a mastectomy and were followed up at the Department of Obstetrics and Gynecology of the Medical University of Vienna between 01.01.2015 and 26.02.2020. RFGT volume (assessed on magnetic resonance imaging) was correlated with the prevalence of an IBLR and a NP. RESULTS A total of 105 patients (126 breasts) following a therapeutic mastectomy were included. After a mean follow-up of 46.0 months an IBLR had occurred in 17 breasts and a NP in 1 breast. A significant difference in RFGT volume was observed between the disease-free cohort and the subgroup with an IBLR or NP (p = .017). A RFGT volume of ≥ 1153 mm3 increased the risk by the factor 3.57 [95%CI 1.27; 10.03]. CONCLUSIONS RFGT volume is associated with an increased risk for an IBLR or NP.
Collapse
|
23
|
Clinical value of contralateral breast cancers detected by pre-operative MRI in patients diagnosed with DCIS: a population-based cohort study-commentary. Eur Radiol 2023; 33:2207-2208. [PMID: 36692600 DOI: 10.1007/s00330-023-09396-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2022] [Revised: 10/30/2022] [Accepted: 11/22/2022] [Indexed: 01/25/2023]
|
24
|
Clinical Decision Support for Axillary Lymph Node Staging in Newly Diagnosed Breast Cancer Patients Based on 18F-FDG PET/MRI and Machine Learning. J Nucl Med 2023; 64:304-311. [PMID: 36137756 PMCID: PMC9902847 DOI: 10.2967/jnumed.122.264138] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Revised: 08/19/2022] [Accepted: 08/19/2022] [Indexed: 02/04/2023] Open
Abstract
In addition to its high prognostic value, the involvement of axillary lymph nodes in breast cancer patients also plays an important role in therapy planning. Therefore, an imaging modality that can determine nodal status with high accuracy in patients with primary breast cancer is desirable. Our purpose was to investigate whether, in newly diagnosed breast cancer patients, machine-learning prediction models based on simple assessable imaging features on MRI or PET/MRI are able to determine nodal status with performance comparable to that of experienced radiologists; whether such models can be adjusted to achieve low rates of false-negatives such that invasive procedures might potentially be omitted; and whether a clinical framework for decision support based on simple imaging features can be derived from these models. Methods: Between August 2017 and September 2020, 303 participants from 3 centers prospectively underwent dedicated whole-body 18F-FDG PET/MRI. Imaging datasets were evaluated for axillary lymph node metastases based on morphologic and metabolic features. Predictive models were developed for MRI and PET/MRI separately using random forest classifiers on data from 2 centers and were tested on data from the third center. Results: The diagnostic accuracy for MRI features was 87.5% both for radiologists and for the machine-learning algorithm. For PET/MRI, the diagnostic accuracy was 89.3% for the radiologists and 91.2% for the machine-learning algorithm, with no significant differences in diagnostic performance between radiologists and the machine-learning algorithm for MRI (P = 0.671) or PET/MRI (P = 0.683). The most important lymph node feature was tracer uptake, followed by lymph node size. With an adjusted threshold, a sensitivity of 96.2% was achieved by the random forest classifier, whereas specificity, positive predictive value, negative predictive value, and accuracy were 68.2%, 78.1%, 93.8%, and 83.3%, respectively. A decision tree based on 3 simple imaging features could be established for MRI and PET/MRI. Conclusion: Applying a high-sensitivity threshold to the random forest results might potentially avoid invasive procedures such as sentinel lymph node biopsy in 68.2% of the patients.
Collapse
|
25
|
Dual-Tracer PET-MRI-Derived Imaging Biomarkers for Prediction of Clinically Significant Prostate Cancer. Curr Oncol 2023; 30:1683-1691. [PMID: 36826090 PMCID: PMC9954891 DOI: 10.3390/curroncol30020129] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 01/11/2023] [Accepted: 01/24/2023] [Indexed: 02/03/2023] Open
Abstract
PURPOSE To investigate if imaging biomarkers derived from 3-Tesla dual-tracer [(18)F]fluoromethylcholine (FMC) and [68Ga]Ga-PSMAHBED-CC conjugate 11 (PSMA)-positron emission tomography can adequately predict clinically significant prostate cancer (csPC). METHODS We assessed 77 biopsy-proven PC patients who underwent 3T dual-tracer PET/mpMRI followed by radical prostatectomy (RP) between 2014 and 2017. We performed a retrospective lesion-based analysis of all cancer foci and compared it to whole-mount histopathology of the RP specimen. The primary aim was to investigate the pretherapeutic role of the imaging biomarkers FMC- and PSMA-maximum standardized uptake values (SUVmax) for the prediction of csPC and to compare it to the mpMRI-methods and PI-RADS score. RESULTS Overall, we identified 104 cancer foci, 69 were clinically significant (66.3%) and 35 were clinically insignificant (33.7%). We found that the combined FMC+PSMA SUVmax were the only significant parameters (p < 0.001 and p = 0.049) for the prediction of csPC. ROC analysis showed an AUC for the prediction of csPC of 0.695 for PI-RADS scoring (95% CI 0.591 to 0.786), 0.792 for FMC SUVmax (95% CI 0.696 to 0.869), 0.852 for FMC+PSMA SUVmax (95% CI 0.764 to 0.917), and 0.852 for the multivariable CHAID model (95% CI 0.763 to 0.916). Comparing the AUCs, we found that FMC+PSMA SUVmax and the multivariable model were significantly more accurate for the prediction of csPC compared to PI-RADS scoring (p = 0.0123, p = 0.0253, respectively). CONCLUSIONS Combined FMC+PSMA SUVmax seems to be a reliable parameter for the prediction of csPC and might overcome the limitations of PI-RADS scoring. Further prospective studies are necessary to confirm these promising preliminary results.
Collapse
|
26
|
Impact of PI-QUAL on PI-RADS and cancer yield in an MRI-TRUS fusion biopsy population. Eur J Radiol 2022; 154:110431. [DOI: 10.1016/j.ejrad.2022.110431] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Revised: 06/21/2022] [Accepted: 06/30/2022] [Indexed: 11/26/2022]
|
27
|
Evaluation des PI-QUAL-Scores für die Prostata-MRT: Hält er was er verspricht? ROFO-FORTSCHR RONTG 2022. [DOI: 10.1055/s-0042-1749905] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
28
|
Breast MRI: does a clinical decision algorithm outweigh reader experience? Eur Radiol 2022; 32:6557-6564. [PMID: 35852572 PMCID: PMC9474540 DOI: 10.1007/s00330-022-09015-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Revised: 05/30/2022] [Accepted: 07/02/2022] [Indexed: 11/28/2022]
Abstract
Objectives Due to its high sensitivity, DCE MRI of the breast (MRIb) is increasingly used for both screening and assessment purposes. The Kaiser score (KS) is a clinical decision algorithm, which formalizes and guides diagnosis in breast MRI and is expected to compensate for lesser reader experience. The aim was to evaluate the diagnostic performance of untrained residents using the KS compared to off-site radiologists experienced in breast imaging using only MR BI-RADS. Methods Three off-site, board-certified radiologists, experienced in breast imaging, interpreted MRIb according to the MR BI-RADS scale. The same studies were read by three residents in radiology without prior training in breast imaging using the KS. All readers were blinded to clinical information. Histology was used as the gold standard. Statistical analysis was conducted by comparing the AUC of the ROC curves. Results A total of 80 women (median age 52 years) with 93 lesions (32 benign, 61 malignant) were included. The individual within-group performance of the three expert readers (AUC 0.723–0.742) as well as the three residents was equal (AUC 0.842–0.928), p > 0.05, respectively. But, the rating of each resident using the KS significantly outperformed the experts’ ratings using the MR BI-RADS scale (p ≤ 0.05). Conclusion The KS helped residents to achieve better results in reaching correct diagnoses than experienced radiologists empirically assigning MR BI-RADS categories in a clinical “problem solving MRI” setting. These results support that reporting breast MRI benefits more from using a diagnostic algorithm rather than expert experience. Key Points • Reporting breast MRI benefits more from using a diagnostic algorithm rather than expert experience in a clinical “problem solving MRI” setting. • The Kaiser score, which provides a clinical decision algorithm for structured reporting, helps residents to reach an expert level in breast MRI reporting and to even outperform experienced radiologists using MR BI-RADS without further formal guidance. Supplementary Information The online version contains supplementary material available at 10.1007/s00330-022-09015-8.
Collapse
|
29
|
How much can abbreviated protocols for breast MRI increase patient throughput? A multi-centric evaluation. Eur J Radiol 2022; 154:110436. [DOI: 10.1016/j.ejrad.2022.110436] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Revised: 06/23/2022] [Accepted: 07/04/2022] [Indexed: 11/03/2022]
|
30
|
Contrast-enhanced Mammography versus Contrast-enhanced Breast MRI: A Systematic Review and Meta-Analysis. Radiology 2022; 305:94-103. [PMID: 36154284 DOI: 10.1148/radiol.212530] [Citation(s) in RCA: 32] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Background Contrast-enhanced mammography (CEM) is a more accessible alternative to contrast-enhanced MRI (CE-MRI) in breast imaging, but a summary comparison of published studies is lacking. Purpose To directly compare the performance of CEM and CE-MRI regarding sensitivity, specificity, and negative predictive value in detecting breast cancer, involving all publicly available studies in the English language. Materials and Methods Two readers extracted characteristics of studies investigating the comparative diagnostic performance of CEM and CE-MRI in detecting breast cancer. Studies published until April 2021 were eligible. Sensitivity, specificity, negative predictive value, and positive and negative likelihood ratios were calculated using bivariate random effects models. A Fagan nomogram was used to identify the maximum pretest probability at which posttest probabilities of a negative CEM or CE-MRI examination were in line with the 2% malignancy rate benchmark for downgrading a Breast Imaging Reporting and Data System (BI-RADS) category 4 to a BI-RADS category 3 result. I 2 statistics, Deeks funnel plot asymmetry test for publication bias, and meta-regression were used. Results Seven studies investigating 1137 lesions (654 malignant, 483 benign) with an average cancer prevalence of 65.3% (range: 47.3%-82.2%) were included. No publication bias was found (P = .57). While the positive likelihood ratio was equal at a value of 3.1 for CE-MRI and 3.6 for CEM, the negative likelihood ratio of CE-MRI (0.04) was lower than that with CEM (0.12). CE-MRI had higher sensitivity for breast cancer than CEM (97% [95% CI: 86, 99] vs 91% [95% CI: 77, 97], respectively; P < .001) but lower specificity (69% [95% CI: 46, 85] vs 74% [95% CI: 52, 89]; P = .09). A Fagan nomogram demonstrated that the maximum pretest probability at which both tests could rule out breast cancer was 33% for CE-MRI and 14% for CEM. Furthermore, iodine concentration was positively associated with CEM sensitivity and negatively associated with its specificity (P = .04 and P < .001, respectively). Conclusion Contrast-enhanced MRI had superior sensitivity and negative likelihood ratios with higher pretest probabilities to rule out malignancy compared with contrast-enhanced mammography. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Mann and Veldhuis in this issue.
Collapse
|
31
|
Feasibility and Optimal Time Point of [68Ga]Gallium-labeled Prostate-specific Membrane Antigen Ligand Positron Emission Tomography Imaging in Patients Undergoing Cytoreductive Surgery After Systemic Therapy for Primary Oligometastatic Prostate Cancer: Implications for Patient Selection and Extent of Surgery. EUR UROL SUPPL 2022; 40:117-124. [PMID: 35638090 PMCID: PMC9142741 DOI: 10.1016/j.euros.2022.04.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/10/2022] [Indexed: 11/26/2022] Open
Abstract
Background Prostate-specific membrane antigen (PSMA) targeted molecular imaging using positron emission tomography (PET) has significantly improved the diagnosis and treatment of prostate cancer (PCA). Objective To assess the feasibility and compare the diagnostic accuracy of [68Ga]Ga-PSMA-11 PET images taken at baseline, before the initiation of systemic treatment and preoperative images, using histopathology after cytoreductive surgery as reference. Design, setting, and participants We identified 20 patients in our prospectively maintained database with primary oligometastatic PCA who underwent cytoreductive radical prostatectomy and superextended pelvic lymph node dissection after systemic therapy, who had baseline and preoperative [68Ga]Ga-PSMA-11 PET imaging available. Outcome measurements and statistical analysis We performed a region-based analysis to determine the diagnostic accuracy of imaging, using pathology as a reference. Regions were predefined as prostate, internal iliac left/right, obturator left/right, external iliac left/right, common iliac left/right, and presacral. Results and limitations Sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV), and diagnostic effectiveness were, respectively, 95.65%, 78.22%, 98.39%, 57.89%, and 83.00% for baseline [68Ga]Ga-PSMA-11 PET, compared to 56.52%, 98.05%, 88.30%, 89.66%, and 88.50% for preoperative [68Ga]Ga-PSMA-11 PET. On a receiver operating characteristic analysis, the diagnostic accuracy of baseline [68Ga]Ga-PSMA-11 PET with an area under the curve (AUC) of 0.87 (95% confidence interval [CI] 0.83–0.92) was significantly better than that of preoperative [68Ga]Ga-PSMA-11 PET after systemic therapy with an AUC of 0.77 (95% CI 0.70–0.85, p = 0.01). Conclusions Baseline imaging, [68Ga]Ga-PSMA-11 PET has significantly better diagnostic accuracy, sensitivity, and NPV than images obtained preoperatively, in systemically pretreated patients. If a patient is suitable for local treatment and complete resection of the residual tumor is intended, [68Ga]Ga-PSMA-11 PET images taken prior to systemic therapy are significantly more accurate in selecting the relevant lymph nodes for resection. Patient summary We found that prostate-specific membrane antigen positron emission tomography (PSMA-PET) imaging used early, before hormonal therapy or chemotherapy, provides more accurate information about the spread of the disease, than if used immediately before surgery but after hormonal therapy or chemotherapy. Early use of PSMA-PET has the potential to improve therapy also at later stages of the disease.
Collapse
|
32
|
Breast cancer screening in women with extremely dense breasts recommendations of the European Society of Breast Imaging (EUSOBI). Eur Radiol 2022; 32:4036-4045. [PMID: 35258677 PMCID: PMC9122856 DOI: 10.1007/s00330-022-08617-6] [Citation(s) in RCA: 115] [Impact Index Per Article: 57.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Revised: 01/21/2022] [Accepted: 01/27/2022] [Indexed: 02/07/2023]
Abstract
Breast density is an independent risk factor for the development of breast cancer and also decreases the sensitivity of mammography for screening. Consequently, women with extremely dense breasts face an increased risk of late diagnosis of breast cancer. These women are, therefore, underserved with current mammographic screening programs. The results of recent studies reporting on contrast-enhanced breast MRI as a screening method in women with extremely dense breasts provide compelling evidence that this approach can enable an important reduction in breast cancer mortality for these women and is cost-effective. Because there is now a valid option to improve breast cancer screening, the European Society of Breast Imaging (EUSOBI) recommends that women should be informed about their breast density. EUSOBI thus calls on all providers of mammography screening to share density information with the women being screened. In light of the available evidence, in women aged 50 to 70 years with extremely dense breasts, the EUSOBI now recommends offering screening breast MRI every 2 to 4 years. The EUSOBI acknowledges that it may currently not be possible to offer breast MRI immediately and everywhere and underscores that quality assurance procedures need to be established, but urges radiological societies and policymakers to act on this now. Since the wishes and values of individual women differ, in screening the principles of shared decision-making should be embraced. In particular, women should be counselled on the benefits and risks of mammography and MRI-based screening, so that they are capable of making an informed choice about their preferred screening method. KEY POINTS: • The recommendations in Figure 1 summarize the key points of the manuscript.
Collapse
|
33
|
Rectal preparation significantly improves prostate imaging quality: Assessment of the PI-QUAL score with visual grading characteristics. Eur J Radiol 2022; 147:110145. [PMID: 35007983 DOI: 10.1016/j.ejrad.2021.110145] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2021] [Revised: 12/23/2021] [Accepted: 12/29/2021] [Indexed: 01/13/2023]
Abstract
PURPOSE To investigate the effects of a rectal preparation regimen, that consisted of a rectal cleansing enema and an endorectal gel filling protocol, on prostate imaging quality (PI-QUAL). METHODS Multiparametric MRI (mpMRI) was performed in 150 consecutive patients divided into two groups of 75 patients. One group received a rectal preparation with a cleansing enema and endorectal gel filling (median age 65.3 years, median PSA level 6 ng/ml). The other patient group did not receive such a preparation (median age 64 years, median PSA level 6 ng/ml). Two uroradiologists independently rated general image quality and lesion visibility on diffusion-weighted imaging (DWI), T2-weighted (T2w), and dynamic contrast-enhanced (DCE) images using a five-point ordinal scale. In addition, two uroradiologists assigned PI-QUAL scores, using the dedicated scoring sheet. Data sets were compared using visual grading characteristics (VGC) and receiver operating characteristics (ROC)/ area under the curve (AUC) analysis. RESULTS VGC revealed significantly better general image quality for DWI (AUC R1 0.708 (0.628-0.779 CI, p < 0.001; AUC R2 0.687 (0.606-0.760 CI, p < 0.001) and lesion visibility for both readers (AUC R1 0.729 (0.607-0.831 CI, p < 0.001); AUC R2 0.714 (0.590-0.818CI, p < 0.001) in the preparation group. For T2w imaging, rectal preparation resulted in significantly better lesion visibility for both readers (R1 0.663 (0.537-0.774 CI, p = 0.014; R2 0.663 (0.537-0.774 CI, p = 0.014)). Averaged PI-QUAL scores were significantly improved with rectal preparation (AUC R3/R4 0.667, CI 0.581-0.754, p < 0.001). CONCLUSION Rectal preparation significantly improved prostate imaging quality (PI-QUAL) and lesion visibility. Hence, a rectal preparation regimen consisting of a rectal cleansing enema and an endorectal gel filling could be considered.
Collapse
|
34
|
Magnetic resonance imaging before breast cancer surgery: results of an observational multicenter international prospective analysis (MIPA). Eur Radiol 2021; 32:1611-1623. [PMID: 34643778 PMCID: PMC8831264 DOI: 10.1007/s00330-021-08240-x] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2021] [Revised: 07/20/2021] [Accepted: 08/02/2021] [Indexed: 02/08/2023]
Abstract
OBJECTIVES Preoperative breast magnetic resonance imaging (MRI) can inform surgical planning but might cause overtreatment by increasing the mastectomy rate. The Multicenter International Prospective Analysis (MIPA) study investigated this controversial issue. METHODS This observational study enrolled women aged 18-80 years with biopsy-proven breast cancer, who underwent MRI in addition to conventional imaging (mammography and/or breast ultrasonography) or conventional imaging alone before surgery as routine practice at 27 centers. Exclusion criteria included planned neoadjuvant therapy, pregnancy, personal history of any cancer, and distant metastases. RESULTS Of 5896 analyzed patients, 2763 (46.9%) had conventional imaging only (noMRI group), and 3133 (53.1%) underwent MRI that was performed for diagnosis, screening, or unknown purposes in 692/3133 women (22.1%), with preoperative intent in 2441/3133 women (77.9%, MRI group). Patients in the MRI group were younger, had denser breasts, more cancers ≥ 20 mm, and a higher rate of invasive lobular histology than patients who underwent conventional imaging alone (p < 0.001 for all comparisons). Mastectomy was planned based on conventional imaging in 22.4% (MRI group) versus 14.4% (noMRI group) (p < 0.001). The additional planned mastectomy rate in the MRI group was 11.3%. The overall performed first- plus second-line mastectomy rate was 36.3% (MRI group) versus 18.0% (noMRI group) (p < 0.001). In women receiving conserving surgery, MRI group had a significantly lower reoperation rate (8.5% versus 11.7%, p < 0.001). CONCLUSIONS Clinicians requested breast MRI for women with a higher a priori probability of receiving mastectomy. MRI was associated with 11.3% more mastectomies, and with 3.2% fewer reoperations in the breast conservation subgroup. KEY POINTS • In 19% of patients of the MIPA study, breast MRI was performed for screening or diagnostic purposes. • The current patient selection to preoperative breast MRI implies an 11% increase in mastectomies, counterbalanced by a 3% reduction of the reoperation rate. • Data from the MIPA study can support discussion in tumor boards when preoperative MRI is under consideration and should be shared with patients to achieve informed decision-making.
Collapse
|
35
|
Microstructural breast tissue characterization: A head-to-head comparison of Diffusion Weighted Imaging and Acoustic Radiation Force Impulse elastography with clinical implications. Eur J Radiol 2021; 143:109926. [PMID: 34438330 DOI: 10.1016/j.ejrad.2021.109926] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2021] [Revised: 08/12/2021] [Accepted: 08/14/2021] [Indexed: 01/08/2023]
Abstract
PURPOSE Head-to-head comparison of Diffusion Weighted Imaging (DWI) and Acoustic Radiation Force Impulse (ARFI) elastography regarding the characterization of breast lesions in an assessment setting. METHOD Patients undergoing an ultrasound examination including ARFI and an MRI protocol including DWI for the characterization of a BI-RADS 3-5 breast lesion between 06/2013 and 10/2016 were eligible for inclusion in this retrospective, IRB-approved study. 60 patients (30-84 years, median 50) with a median lesion size of 16 mm (range 5-55 mm) were included. The maximum shear wave velocity (SWVmax) and mean apparent diffusion coefficient (ADCmean) for each lesion were retrospectively evaluated by a radiologist experienced in the technique. Histology was the reference standard. Diagnostic performances of ARFI and DWI were assessed using ROC curve analysis. Spearman's rank correlation coefficient and multivariate logistic regression were used to investigate the independence of both tests regarding their diagnostic information to distinguish benign from malignant lesions. RESULTS Corresponding areas under the ROC curve for differentiation of benign (n = 16) and malignant (n = 49) lesions were 0.822 (ARFI) and 0.871 (DWI, p-value = 0.48). SWVmax and ADCmean values showed a significant negative correlation (ρ = -0.501, p-value < 0.001). In multivariate analysis, combination of ARFI and DWI did not improve the results of each single modality, thus no significant independent diagnostic information was present. CONCLUSION Significant correlation between quantitative findings of ARFI and DWI in breast lesions exists. Thus, ARFI provides similar diagnostic information as a DWI-including protocol of an additional "problem-solving" MRI for the characterization of a sonographically evident breast lesion, improving the immediate patient management in the assessment setting.
Collapse
|
36
|
Axillary lymphadenopathy at the time of COVID-19 vaccination: ten recommendations from the European Society of Breast Imaging (EUSOBI). Insights Imaging 2021; 12:119. [PMID: 34417642 PMCID: PMC8378785 DOI: 10.1186/s13244-021-01062-x] [Citation(s) in RCA: 41] [Impact Index Per Article: 13.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Accepted: 07/17/2021] [Indexed: 01/12/2023] Open
Abstract
Unilateral axillary lymphadenopathy is a frequent mild side effect of COVID-19 vaccination. European Society of Breast Imaging (EUSOBI) proposes ten recommendations to standardise its management and reduce unnecessary additional imaging and invasive procedures: (1) in patients with previous history of breast cancer, vaccination should be performed in the contralateral arm or in the thigh; (2) collect vaccination data for all patients referred to breast imaging services, including patients undergoing breast cancer staging and follow-up imaging examinations; (3) perform breast imaging examinations preferentially before vaccination or at least 12 weeks after the last vaccine dose; (4) in patients with newly diagnosed breast cancer, apply standard imaging protocols regardless of vaccination status; (5) in any case of symptomatic or imaging-detected axillary lymphadenopathy before vaccination or at least 12 weeks after, examine with appropriate imaging the contralateral axilla and both breasts to exclude malignancy; (6) in case of axillary lymphadenopathy contralateral to the vaccination side, perform standard work-up; (7) in patients without breast cancer history and no suspicious breast imaging findings, lymphadenopathy only ipsilateral to the vaccination side within 12 weeks after vaccination can be considered benign or probably-benign, depending on clinical context; (8) in patients without breast cancer history, post-vaccination lymphadenopathy coupled with suspicious breast finding requires standard work-up, including biopsy when appropriate; (9) in patients with breast cancer history, interpret and manage post-vaccination lymphadenopathy considering the timeframe from vaccination and overall nodal metastatic risk; (10) complex or unclear cases should be managed by the multidisciplinary team.
Collapse
|
37
|
One view or two views for wide-angle tomosynthesis with synthetic mammography in the assessment setting? Eur Radiol 2021; 32:661-670. [PMID: 34324025 PMCID: PMC8660729 DOI: 10.1007/s00330-021-08079-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2021] [Revised: 04/14/2021] [Accepted: 05/19/2021] [Indexed: 11/30/2022]
Abstract
Objectives To evaluate the diagnostic performance in the assessment setting of three protocols: one-view wide-angle digital breast tomosynthesis (WA-DBT) with synthetic mammography (SM), two-view WA-DBT/SM, and two-view digital mammography (DM). Methods Included in this retrospective study were patients who underwent bilateral two-view DM and WA-DBT. SM were reconstructed from the WA-DBT data. The standard of reference was histology and/or 2 years follow-up. Included were 205 women with 179 lesions (89 malignant, 90 benign). Four blinded readers randomly evaluated images to assess density, lesion type, and level of suspicion according to BI-RADS. Three protocols were evaluated: two-view DM, one-view (mediolateral oblique) WA-DBT/SM, and two-view WA-DBT/SM. Detection rate, sensitivity, specificity, and accuracy were calculated and compared using multivariate analysis. Reading time was assessed. Results The detection rate was higher with two-view WA-DBT/SM (p = 0.063). Sensitivity was higher for two-view WA-DBT/SM compared to two-view DM (p = 0.001) and one-view WA-DBT/SM (p = 0.058). No significant differences in specificity were found. Accuracy was higher with both one-view WA-DBT/SM and two-view WA-DBT/SM compared to DM (p = 0.003 and > 0.001, respectively). Accuracy did not differ between one- and two-view WA-DBT/SM. Two-view WA-DBT/SM performed better for masses and asymmetries. Reading times were significantly longer when WA-DBT was evaluated. Conclusions One-view and two-view WA-DBT/SM can achieve a higher diagnostic performance compared to two-view DM. The detection rate and sensitivity were highest with two-view WA-DBT/SM. Two-view WA-DBT/SM appears to be the most appropriate tool for the assessment of breast lesions. Key Points • Detection rate with two-view wide-angle digital breast tomosynthesis (WA-DBT) is significantly higher than with two-view digital mammography in the assessment setting. • Diagnostic accuracy of one-view and two-view WA-DBT with synthetic mammography (SM) in the assessment setting is higher than that of two-view digital mammography. • Compared to one-view WA-DBT with SM, two-view WA-DBT with SM seems to be the most appropriate tool for the assessment of breast lesions.
Collapse
|
38
|
Abstract
PURPOSE OF REVIEW The purpose of this review was to identify the most recent lines of research focusing on the application of artificial intelligence (AI) in the diagnosis and staging of prostate cancer (PCa) with imaging. RECENT FINDINGS The majority of studies focused on the improvement in the interpretation of bi-parametric and multiparametric magnetic resonance imaging, and in the planning of image guided biopsy. These initial studies showed that AI methods based on convolutional neural networks could achieve a diagnostic performance close to that of radiologists. In addition, these methods could improve segmentation and reduce inter-reader variability. Methods based on both clinical and imaging findings could help in the identification of high-grade PCa and more aggressive disease, thus guiding treatment decisions. Though these initial results are promising, only few studies addressed the repeatability and reproducibility of the investigated AI tools. Further, large-scale validation studies are missing and no diagnostic phase III or higher studies proving improved outcomes regarding clinical decision making have been conducted. SUMMARY AI techniques have the potential to significantly improve and simplify diagnosis, risk stratification and staging of PCa. Larger studies with a focus on quality standards are needed to allow a widespread introduction of AI in clinical practice.
Collapse
|
39
|
A Multicentric Comparison of Apparent Diffusion Coefficient Mapping and the Kaiser Score in the Assessment of Breast Lesions. Invest Radiol 2021; 56:274-282. [PMID: 33122603 DOI: 10.1097/rli.0000000000000739] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
MATERIALS AND METHODS In this multicentric study, individual patient data from 3 different centers were analyzed. Consecutive patients receiving standardized multiparametric breast magnetic resonance imaging for standard nonscreening indications were included. At each center, 2 experienced radiologists with more than 5 years of experience retrospectively interpreted the examinations in consensus and applied the KS to every histologically verified lesion. The corresponding mean ADC of each lesion was measured using a Wielema type 4 region of interest. According to established methods, the KS and ADC were combined, yielding the KS+ score. Diagnostic accuracy was evaluated by the area under the receiver operating characteristics curve (AUROC) and compared between the KS, ADC, and KS+ (DeLong test). Likewise, the potential to help avoid unnecessary biopsies was compared between the KS, ADC, and KS+ based on established high sensitivity thresholds (McNemar test). RESULTS A total of 450 lesions in 414 patients (mean age, 51.5 years; interquartile range, 42-60.8 years) were included, with 219 lesions being malignant (48.7%; 95% confidence interval [CI], 44%-53.4%). The performance of the KS (AUROC, 0.915; CI, 0.886-0.939) was significantly better than that of the ADC (AUROC, 0.848; CI, 0.811-0.880; P < 0.001). The largest difference between these parameters was observed when assessing subcentimeter lesions (AUROC, 0.909 for KS; CI, 0.849-0.950 vs 0.811 for ADC; CI, 0.737-0.871; P = 0.02).The use of the KS+ (AUROC, 0.918; CI, 0.889-0.942) improved the performance slightly, but without any significant difference relative to a single KS or ADC reading (P = 0.64).When applying high sensitivity thresholds for avoiding unnecessary biopsies, the KS and ADC achieved equal sensitivity (97.7% for both; cutoff values, >4 for KS and ≤1.4 × 10-3 mm2/s for ADC). However, the rate of potentially avoidable biopsies was higher when using the KS (specificity: 65.4% for KS vs 32.9% for ADC; P < 0.0001). The KS was superior to the KS+ in avoiding unnecessary biopsies. CONCLUSIONS Both the KS and ADC may be used to distinguish benign from malignant breast lesions. However, KS proved superior in this task including, most of all, when assessing small lesions less than 1 cm. Using the KS may avoid twice as many unnecessary biopsies, and the combination of both the KS and ADS does not improve diagnostic performance.
Collapse
|
40
|
Diffusion-weighted Imaging Allows for Downgrading MR BI-RADS 4 Lesions in Contrast-enhanced MRI of the Breast to Avoid Unnecessary Biopsy. Clin Cancer Res 2021; 27:1941-1948. [PMID: 33446565 PMCID: PMC8406278 DOI: 10.1158/1078-0432.ccr-20-3037] [Citation(s) in RCA: 39] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2020] [Revised: 10/13/2020] [Accepted: 01/06/2021] [Indexed: 12/12/2022]
Abstract
PURPOSE Diffusion-weighted imaging with the calculation of an apparent diffusion coefficient (ADC) has been proposed as a quantitative biomarker on contrast-enhanced MRI (CE-MRI) of the breast. There is a need to approve a generalizable ADC cutoff. The purpose of this study was to evaluate whether a predefined ADC cutoff allows downgrading of BI-RADS 4 lesions on CE-MRI, avoiding unnecessary biopsies. EXPERIMENTAL DESIGN This was a retrospective, multicentric, cross-sectional study. Data from five centers were pooled on the individual lesion level. Eligible patients had a BI-RADS 4 rating on CE-MRI. For each center, two breast radiologists evaluated the images. Data on lesion morphology (mass, non-mass), size, and ADC were collected. Histology was the standard of reference. A previously suggested ADC cutoff (≥1.5 × 10-3 mm2/second) was applied. A negative likelihood ratio of 0.1 or lower was considered as a rule-out criterion for breast cancer. Diagnostic performance indices were calculated by ROC analysis. RESULTS There were 657 female patients (mean age, 42; SD, 14.1) with 696 BI-RADS 4 lesions included. Disease prevalence was 59.5% (414/696). The area under the ROC curve was 0.784. Applying the investigated ADC cutoff, sensitivity was 96.6% (400/414). The potential reduction of unnecessary biopsies was 32.6% (92/282). CONCLUSIONS An ADC cutoff of ≥1.5 × 10-3 mm2/second allows downgrading of lesions classified as BI-RADS 4 on breast CE-MRI. One-third of unnecessary biopsies could thus be avoided.
Collapse
|
41
|
Correct determination of the enhancement curve is critical to ensure accurate diagnosis using the Kaiser score as a clinical decision rule for breast MRI. Eur J Radiol 2021; 138:109630. [PMID: 33744507 DOI: 10.1016/j.ejrad.2021.109630] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2021] [Revised: 02/28/2021] [Accepted: 03/02/2021] [Indexed: 11/30/2022]
Abstract
OBJECTIVES the Kaiser score is increasingly recognized as a valuable tool to improve breast MRI interpretation. Contrast enhancement kinetics are the second most important diagnostic criterion, thus defining the curve type plays a crucial role in Kaiser score assessment. We investigate whether the timepoint used to determine the initial enhancement (earlyor peak) for the signal-intensity time curve analysis affects the diagnostic performance of the Kaiser score. METHODS This IRB-approved, retrospective, single-center study included 70 consecutives histologically verified breast MRI cases. Two off-site breast radiologists independently read all examinations using the Kaiser score, assessing the initial enhancement using three approaches: -first (1 st), second (2nd) and peak (maximum) of either 1 st or 2nd post-contrast timepoints. The initial enhancement was then compared to the last timepoint (delayed enhancement) to determine the curve type. Visual assessment of curve types was used for this study. Diagnostic performance was evaluated by receiver operating characteristics (ROC) analysis. RESULTS Kaiser score reading results using the peak enhancement of either the first or second timepoint performed significantly better than the other approaches (P < 0.05, respectively) and specifically achieved higher sensitivity. Diagnostic accuracy (AUC area under the curve) ranged between 85.4 % and 91.6 %, without significant differences between the two readers (P < 0.5). CONCLUSIONS Diagnostic performance of the Kaiser score is significantly influenced by how the initial enhancement timepoint is determined. Peak enhancement should be used as initial timepoint to avoid pitfalls due to timing or physiological differences.
Collapse
|
42
|
Images Are Data: A Breast Imaging Perspective on a Contemporary Paradigm. ROFO-FORTSCHR RONTG 2021; 193:898-908. [PMID: 33535260 DOI: 10.1055/a-1346-0095] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
BACKGROUND Considering radiological examinations not as mere images, but as a source of data, has become the key paradigm in the diagnostic imaging field. This change of perspective is particularly popular in breast imaging. It allows breast radiologists to apply algorithms derived from computer science, to realize innovative clinical applications, and to refine already established methods. In this context, the terminology "imaging biomarker", "radiomics", and "artificial intelligence" are of pivotal importance. These methods promise noninvasive, low-cost (e. g., in comparison to multigene arrays), and workflow-friendly (automated, only one examination, instantaneous results, etc.) delivery of clinically relevant information. METHODS AND RESULTS This paper is designed as a narrative review on the previously mentioned paradigm. The focus is on key concepts in breast imaging and important buzzwords are explained. For all areas of breast imaging, exemplary studies and potential clinical use cases are discussed. CONCLUSION Considering radiological examination as a source of data may optimize patient management by guiding individualized breast cancer diagnosis and oncologic treatment in the age of precision medicine. KEY POINTS · In conventional breast imaging, examinations are interpreted based on patterns perceivable by visual inspection.. · The radiomics paradigm treats breast images as a source of data, containing information beyond what is visible to our eyes.. · This results in radiomic signatures that may be considered as imaging biomarkers, as they provide diagnostic, predictive, and prognostic information.. · Radiomics derived imaging biomarkers may be used to individualize breast cancer treatment in the era of precision medicine.. · The concept and key research of radiomics in the field of breast imaging will be discussed in this narrative review.. CITATION FORMAT · Dietzel M, Clauser P, Kapetas P et al. Images Are Data: A Breast Imaging Perspective on a Contemporary Paradigm. Fortschr Röntgenstr 2021; 193: 898 - 908.
Collapse
|
43
|
Side of contrast injection and breast size correlate with motion artifacts grade and image quality on breast MRI. Acta Radiol 2021; 62:19-26. [PMID: 32228030 DOI: 10.1177/0284185120912408] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Motion is a relevant cause of artifacts in breast magnetic resonance imaging (MRI), potentially degrading image quality, even with optimized protocols. PURPOSE To investigate the causes of motion artifacts (MA) impacting on image quality (IQ) of contrast-enhanced breast MRI. MATERIAL AND METHODS Retrospective two-center study on consecutive 1.5-T contrast-enhanced breast MRI, independently reviewed by two radiologists on first subtracted and maximum intensity projection images to define the side most affected by MA. IQ was scored as 1 (optimal), 2 (reduced, but without reduction of diagnostic power), or 3 (reduced, with reduced diagnostic power). Correlations with injection side, breast size (A/B vs. C/D cups), patient age, clinical indication, and MRI scanner/protocol were assessed using χ2 and Fisher's exact statistics. RESULTS In total, 237 examinations were included, with right injection performed in 124 (52%) and left in 113 (48%). MA were more frequent on the side ipsilateral to the injection (144/237, 61%, 95% confidence interval [CI] 54-67%) than on the contralateral (93/237, 95% CI 33-46%) (P < 0.001); IQ was scored 1 in 154/237 (65%), 2 in 63/237 (27%), and 3 in 20/237 (8%) examinations; patients with A/B cups showed higher IQ score than patients with C/D cups (scores 1, 2, and 3: 54% vs. 70%; 29% vs. 25%; 17% vs. 5%, respectively, P = 0.002). No significant correlations were found for MA (P≥0.106) or IQ (P ≥ 0.318) between ipsi- or contralateral injection and right/left injection, breast size, age, indication, or scanner/protocol. CONCLUSION MA were more frequent in breasts ipsilateral to contrast injection and showed a reduced IQ for small breasts.
Collapse
|
44
|
A risk stratification algorithm for lesions of uncertain malignant potential diagnosed by vacuum-assisted breast biopsy (VABB) of mammographic microcalcifications. Eur J Radiol 2020; 135:109479. [PMID: 33370641 DOI: 10.1016/j.ejrad.2020.109479] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2020] [Revised: 11/28/2020] [Accepted: 12/13/2020] [Indexed: 11/17/2022]
Abstract
PURPOSE To investigate a risk stratification strategy for lesions of uncertain malignant potential (B3) diagnosed by vacuum-assisted breast biopsy (VABB) of mammographic microcalcifications. METHODS Patients who underwent VABB for microcalcification-only lesions with a diagnosis of B3 and subsequent surgery were included in this retrospective, IRB-approved study. Seventy-six B3-lesions (final histology: 66 benign, 10 malignant) were included (Tr). Data on B3 lesion type and presence of atypia, microcalcification characteristics (BI-RADS), removal at biopsy and concomitant lesions were collected. After univariate analysis (Chi-square test), data were combined into a risk stratification algorithm by using a ten-fold, cross-validated Classification and Regression Tree analysis (CRT). The algorithm was tested on a testing dataset (Te) of 23 B3-lesions (six malignant, 17 benign). RESULTS Malignancy was more frequent in women with a concomitant cancer (P < 0.001) and highly suspicious microcalcifications (P < 0.001). The CRT algorithm retained three characteristics: morphology; presence of atypia; presence of concomitant cancer. The algorithm identified 25/76 (32.9 %,Tr) and 6/23 (26.1 %,Te) lesions at low risk of malignancy. No malignant cases were identified at surgery (0/31). There were 3/76 (3.9 %,Tr) and 1/23 (4.3 %,Te) lesions assigned as high-risk by the algorithm and confirmed at surgery (4/4). In the remaining lesions (48/76, 63.1 %,Tr; 16/23, 69.6 %,Te), malignancy rates varied between 9% and 88.4 %; thus, surgery could not have been avoided. CONCLUSION We constructed and tested a risk stratification algorithm for B3 microcalcifications, including clinical, imaging, and pathological features, to assign probabilities of malignancy, which has the potential to reduce unnecessary surgeries.
Collapse
|
45
|
Breast imaging and cancer diagnosis during the COVID-19 pandemic: recommendations from the Italian College of Breast Radiologists by SIRM. LA RADIOLOGIA MEDICA 2020; 125:926-930. [PMID: 32661780 PMCID: PMC7357257 DOI: 10.1007/s11547-020-01254-3] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 05/13/2020] [Accepted: 07/02/2020] [Indexed: 12/17/2022]
Abstract
The Italian College of Breast Radiologists by the Italian Society of Medical Radiology (SIRM) provides recommendations for breast care provision and procedural prioritization during COVID-19 pandemic, being aware that medical decisions must be currently taken balancing patient's individual and community safety: (1) patients having a scheduled or to-be-scheduled appointment for in-depth diagnostic breast imaging or needle biopsy should confirm the appointment or obtain a new one; (2) patients who have suspicious symptoms of breast cancer (in particular: new onset palpable nodule; skin or nipple retraction; orange peel skin; unilateral secretion from the nipple) should request non-deferrable tests at radiology services; (3) asymptomatic women performing annual mammographic follow-up after breast cancer treatment should preferably schedule the appointment within 1 year and 3 months from the previous check, compatibly with the local organizational conditions; (4) asymptomatic women who have not responded to the invitation for screening mammography after the onset of the pandemic or have been informed of the suspension of the screening activity should schedule the check preferably within 3 months from the date of the not performed check, compatibly with local organizational conditions. The Italian College of Breast Radiologists by SIRM recommends precautions to protect both patients and healthcare workers (radiologists, radiographers, nurses, and reception staff) from infection or disease spread on the occasion of breast imaging procedures, particularly mammography, breast ultrasound, breast magnetic resonance imaging, and breast intervention procedures.
Collapse
|
46
|
Combined texture analysis and machine learning in suspicious calcifications detected by mammography: Potential to avoid unnecessary stereotactical biopsies. Eur J Radiol 2020; 132:109309. [PMID: 33010682 DOI: 10.1016/j.ejrad.2020.109309] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2020] [Revised: 08/28/2020] [Accepted: 09/18/2020] [Indexed: 10/23/2022]
Abstract
OBJECTIVES To investigate whether combined texture analysis and machine learning can distinguish malignant from benign suspicious mammographic calcifications, to find an exploratory rule-out criterion to potentially avoid unnecessary benign biopsies. METHODS Magnification views of 235 patients which underwent vacuum-assisted biopsy of suspicious calcifications (BI-RADS 4) during a two-year period were retrospectively analyzed using the texture analysis tool MaZda (Version 4.6). Microcalcifications were manually segmented and analyzed by two readers, resulting in 249 image features from gray-value histogram, gray-level co-occurrence and run-length matrices. After feature reduction with principal component analysis (PCA), a multilayer perceptron (MLP) artificial neural network was trained using histological results as the reference standard. For training and testing of this model, the dataset was split into 70 % and 30 %. ROC analysis was used to calculate diagnostic performance indices. RESULTS 226 patients (150 benign, 76 malignant) were included in the final analysis due to missing data in 9 cases. Feature selection yielded nine image features for MLP training. Area under the ROC-curve in the testing dataset (n = 54) was 0.82 (95 %-CI: 0.70-0.94) and 0.832 (95 %-CI 0.72-0.94) for both readers, respectively. A high sensitivity threshold criterion was identified in the training dataset and successfully applied to the testing dataset, demonstrating the potential to avoid 37.1-45.7 % of unnecessary biopsies at the cost of one false-negative for each reader. CONCLUSION Combined texture analysis and machine learning could be used for risk stratification in suspicious mammographic calcifications. At low costs in terms of false-negatives, unnecessary biopsies could be avoided.
Collapse
|
47
|
Non-Invasive Assessment of Hypoxia and Neovascularization with MRI for Identification of Aggressive Breast Cancer. Cancers (Basel) 2020; 12:cancers12082024. [PMID: 32721996 PMCID: PMC7464174 DOI: 10.3390/cancers12082024] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2020] [Revised: 07/20/2020] [Accepted: 07/21/2020] [Indexed: 01/01/2023] Open
Abstract
The aim of this study was to investigate the potential of magnetic resonance imaging (MRI) for a non-invasive synergistic assessment of tumor microenvironment (TME) hypoxia and induced neovascularization for the identification of aggressive breast cancer. Fifty-three female patients with breast cancer underwent multiparametric breast MRI including quantitative blood-oxygen-level-dependent (qBOLD) imaging for hypoxia and vascular architecture mapping for neovascularization. Quantitative MRI biomarker maps of oxygen extraction fraction (OEF), metabolic rate of oxygen (MRO2), mitochondrial oxygen tension (mitoPO2), microvessel radius (VSI), microvessel density (MVD), and microvessel type indicator (MTI) were calculated. Histopathology was the standard of reference. Histopathological markers (vascular endothelial growth factor receptor 1 (FLT1), podoplanin, hypoxia-inducible factor 1-alpha (HIF-1alpha), carbonic anhydrase 9 (CA IX), vascular endothelial growth factor C (VEGF-C)) were used to confirm imaging biomarker findings. Univariate and multivariate regression analyses were performed to differentiate less aggressive luminal from aggressive non-luminal (HER2-positive, triple negative) malignancies and assess the interplay between hypoxia and neoangiogenesis markers. Aggressive non-luminal cancers (n = 40) presented with significantly higher MRO2 (i.e., oxygen consumption), lower mitoPO2 values (i.e., hypoxia), lower MTI, and higher MVD than less aggressive cancers (n = 13). Data suggest that a model derived from OEF, mitoPO2, and MVD can predict tumor proliferation rate. This novel MRI approach, which can be easily implemented in routine breast MRI exams, aids in the non-invasive identification of aggressive breast cancer.
Collapse
|
48
|
Stand-Alone Artificial Intelligence for Breast Cancer Detection in Mammography: Comparison With 101 Radiologists. J Natl Cancer Inst 2020; 111:916-922. [PMID: 30834436 DOI: 10.1093/jnci/djy222] [Citation(s) in RCA: 268] [Impact Index Per Article: 67.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2018] [Revised: 10/06/2018] [Accepted: 11/29/2018] [Indexed: 12/11/2022] Open
Abstract
BACKGROUND Artificial intelligence (AI) systems performing at radiologist-like levels in the evaluation of digital mammography (DM) would improve breast cancer screening accuracy and efficiency. We aimed to compare the stand-alone performance of an AI system to that of radiologists in detecting breast cancer in DM. METHODS Nine multi-reader, multi-case study datasets previously used for different research purposes in seven countries were collected. Each dataset consisted of DM exams acquired with systems from four different vendors, multiple radiologists' assessments per exam, and ground truth verified by histopathological analysis or follow-up, yielding a total of 2652 exams (653 malignant) and interpretations by 101 radiologists (28 296 independent interpretations). An AI system analyzed these exams yielding a level of suspicion of cancer present between 1 and 10. The detection performance between the radiologists and the AI system was compared using a noninferiority null hypothesis at a margin of 0.05. RESULTS The performance of the AI system was statistically noninferior to that of the average of the 101 radiologists. The AI system had a 0.840 (95% confidence interval [CI] = 0.820 to 0.860) area under the ROC curve and the average of the radiologists was 0.814 (95% CI = 0.787 to 0.841) (difference 95% CI = -0.003 to 0.055). The AI system had an AUC higher than 61.4% of the radiologists. CONCLUSIONS The evaluated AI system achieved a cancer detection accuracy comparable to an average breast radiologist in this retrospective setting. Although promising, the performance and impact of such a system in a screening setting needs further investigation.
Collapse
|
49
|
The Kaiser score reliably excludes malignancy in benign contrast-enhancing lesions classified as BI-RADS 4 on breast MRI high-risk screening exams. Eur Radiol 2020; 30:6052-6061. [PMID: 32504098 PMCID: PMC7553895 DOI: 10.1007/s00330-020-06945-z] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2020] [Revised: 04/08/2020] [Accepted: 05/08/2020] [Indexed: 11/29/2022]
Abstract
OBJECTIVES MRI is an integral part of breast cancer screening in high-risk patients. We investigated whether the application of the Kaiser score, a clinical decision-support tool, may be used to exclude malignancy in contrast-enhancing lesions classified as BI-RADS 4 on breast MRI screening exams. METHODS This retrospective study included 183 consecutive, histologically proven, suspicious (MR BI-RADS 4) lesions detected within our local high-risk screening program. All lesions were evaluated according to the Kaiser score for breast MRI by three readers blinded to the final histopathological diagnosis. The Kaiser score ranges from 1 (lowest, cancer very unlikely) to 11 (highest, cancer very likely) and reflects increasing probabilities of malignancy, with scores greater than 4 requiring biopsy. Receiver operating characteristic (ROC) curve analysis was used to evaluate diagnostic accuracy. RESULTS There were 142 benign and 41 malignant lesions, diagnosed in 159 patients (mean age, 43.6 years). Median Kaiser scores ranged between 2 and 5 in benign and 7 and 8 in malignant lesions. For all lesions, the Kaiser score's accuracy, represented by the area under the curve (AUC), ranged between 86.5 and 90.2. The sensitivity of the Kaiser score was high, between 95.1 and 97.6% for all lesions, and was best in mass lesions. Application of the Kaiser score threshold for malignancy (≤ 4) could have potentially avoided 64 (45.1%) to 103 (72.5%) unnecessary biopsies in 142 benign lesions previously classified as BI-RADS 4. CONCLUSIONS The use of Kaiser score in high-risk MRI screening reliably excludes malignancy in more than 45% of contrast-enhancing lesions classified as BI-RADS 4. KEY POINTS • The Kaiser score shows high diagnostic accuracy in identifying malignancy in contrast-enhancing lesions in patients undergoing high-risk screening for breast cancer. • The application of the Kaiser score may avoid > 45% of unnecessary breast biopsies in high-risk patients. • The Kaiser score aids decision-making in high-risk breast cancer MRI screening programs.
Collapse
|
50
|
Development of a Non-invasive Assessment of Hypoxia and Neovascularization with Magnetic Resonance Imaging in Benign and Malignant Breast Tumors: Initial Results. Mol Imaging Biol 2020; 21:758-770. [PMID: 30478507 DOI: 10.1007/s11307-018-1298-4] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
PURPOSE To develop a novel magnetic resonance imaging (MRI) approach for the noninvasive assessment of hypoxia and neovascularization in breast tumors. PROCEDURES In this IRB-approved prospective study, 20 patients with suspicious breast lesions (BI-RADS 4/5) underwent multiparametric breast MRI including quantitative BOLD (qBOLD) and vascular architecture mapping (VAM). Custom-made in-house MatLab software was used for qBOLD and VAM data postprocessing and calculation of quantitative MRI biomarker maps of oxygen extraction fraction (OEF), metabolic rate of oxygen (MRO2), and mitochondrial oxygen tension (mitoPO2) to measure tissue hypoxia and neovascularization including vascular architecture including microvessel radius (VSI), density (MVD), and type (MTI). Histopathology was used as standard of reference. Appropriate statistics were performed to assess and compare correlations between MRI biomarkers for hypoxia and neovascularization. RESULTS qBOLD and VAM data with good quality were obtained from all patients with 13 invasive ductal carcinoma (IDC) and 7 benign breast tumors with a lesion diameter of at least 10 mm in all spatial directions. MRI biomarker maps of oxygen metabolism and neovascularization demonstrated intratumoral spatial heterogeneity with a broad range of biomarker values. Bulk tumor neovasculature consisted of draining venous microvasculature with slow flowing blood. High OEF and low mitoPO2 were associated with low MVD and vice versa. The heterogeneous pattern of MRO2 values showed spatial congruence with VSI. IDCs showed significantly higher MRO2 (P = 0.007), lower mitoPO2 (P = 0.021), higher MVD (P = 0.005), and lower (i.e., more pathologic) MTI (P = 0.001) compared with benign breast tumors. These results indicate that IDCs consume more oxygen and are more hypoxic and neovascularized than benign tumors. CONCLUSIONS We developed a novel MRI approach for the noninvasive assessment of hypoxia and neovascularization in benign and malignant breast tumors that can be easily integrated in a diagnostic MRI protocol and provides insight into intratumoral heterogeneity.
Collapse
|