1
|
Impact of Academia-Government Collaboration on Laboratory Medicine Standardization in South Korea: analysis of eight years creatinine proficiency testing experience. Clin Chem Lab Med 2024; 62:861-869. [PMID: 37999449 DOI: 10.1515/cclm-2023-1160] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Accepted: 11/14/2023] [Indexed: 11/25/2023]
Abstract
OBJECTIVES To evaluate the performance of the Academia-Government Collaboration for Laboratory Medicine Standardization in Korea (KR-STDZN) based on data from KR-STDZN proficiency testing (KR-STDZN-PT) for creatinine over eight years (2015-2022). METHODS We used KR-STDZN-PT data of creatinine tests from 2015 to 2022. Acceptance of the participating institutions' test results was assessed by calculating the acceptance performance as absolute bias (absBias%), total coefficient of variance (tCV%), and total error (TE%) for each sample using six measurements from each institution and true values of each reference material. The test result was considered acceptable when absBias%, tCV%, and TE% were <5.10, <3.20, and <11.40 %, respectively. The proportion of acceptable institutions among all participating institutions in each round was defined as the acceptance rate. Improvements in absBias%, tCV%, and TE% were analyzed using creatinine concentration ranges in samples. RESULTS The number of participating institutions increased from 2015 to 2017 but remained consistent since 2018. The acceptance rates for absBias% and TE% increased from 52.2 and 77.6 %, in 2015 and to 90.7 and 96.3 %, in 2022, respectively. The acceptance rate for tCV% remained in the 90 % range for eight years. When creatinine <3 mg/dL, mean absBias%, and mean TE% improved significantly in 2021-2022 compared to 2015-2016 (p<0.05). When creatinine >3 mg/dL, acceptance performance did not improve. Mean tCV% remained consistent annually regardless of creatinine concentration. No significant variations in test methods were observed. CONCLUSIONS The collaboration between academia and the government improved creatinine testing quality. Nevertheless, KR-STDZN must be expanded and refined.
Collapse
|
2
|
Reverse Transcription-PCR-based Sanger Sequencing-confirmed Exon-skipping Effect of a Novel GEN1 Intronic Variant (c.1408+4A>G). Ann Lab Med 2024; 44:188-191. [PMID: 37840312 PMCID: PMC10628752 DOI: 10.3343/alm.2023.0163] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2023] [Revised: 07/22/2023] [Accepted: 09/12/2023] [Indexed: 10/17/2023] Open
|
3
|
Skeletal Muscle Mass Measurement via Bioelectrical Impedance Analysis as an Aid to Screen for Chronic Kidney Disease in Routine Health Checkups. Ann Lab Med 2024; 44:100-102. [PMID: 37665292 PMCID: PMC10485860 DOI: 10.3343/alm.2024.44.1.100] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2023] [Revised: 05/18/2023] [Accepted: 07/05/2023] [Indexed: 09/05/2023] Open
|
4
|
Improving the Work Efficiency of Therapeutic Drug Monitoring Reports Through the Establishment of an Automated Data Transfer System. Ann Lab Med 2023; 43:628-631. [PMID: 37387497 DOI: 10.3343/alm.2023.43.6.628] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 04/25/2023] [Accepted: 05/31/2023] [Indexed: 07/01/2023] Open
|
5
|
A New Strategy for Evaluating the Quality of Laboratory Results for Big Data Research: Using External Quality Assessment Survey Data (2010-2020). Ann Lab Med 2023; 43:425-433. [PMID: 37080743 PMCID: PMC10151270 DOI: 10.3343/alm.2023.43.5.425] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2022] [Revised: 02/01/2023] [Accepted: 03/24/2023] [Indexed: 04/22/2023] Open
Abstract
Background To ensure valid results of big data research in the medical field, the input laboratory results need to be of high quality. We aimed to establish a strategy for evaluating the quality of laboratory results suitable for big data research. Methods We used Korean Association of External Quality Assessment Service (KEQAS) data to retrospectively review multicenter data. Seven measurands were analyzed using commutable materials: HbA1c, creatinine (Cr), total cholesterol (TC), triglyceride (TG), alpha-fetoprotein (AFP), prostate-specific antigen (PSA), and cardiac troponin I (cTnI). These were classified into three groups based on their standardization or harmonization status. HbA1c, Cr, TC, TG, and AFP were analyzed with respect to peer group values. PSA and cTnI were analyzed in separate peer groups according to the calibrator type and manufacturer, respectively. The acceptance rate and absolute percentage bias at the medical decision level were calculated based on biological variation criteria. Results The acceptance rate (22.5%-100%) varied greatly among the test items, and the mean percentage biases were 0.6%-5.6%, 1.0%-9.6%, and 1.6%-11.3% for all items that satisfied optimum, desirable, and minimum criteria, respectively. Conclusions The acceptance rate of participants and their external quality assessment (EQA) results exhibited statistically significant differences according to the quality grade for each criterion. Even when they passed the EQA standards, the test results did not guarantee the quality requirements for big data. We suggest that the KEQAS classification can serve as a guide for building big data.
Collapse
|
6
|
Usefulness and performance evaluation of serum KL-6 and SP-A assays in healthy individuals and patients with interstitial lung disease. Clin Biochem 2023:110609. [PMID: 37414329 DOI: 10.1016/j.clinbiochem.2023.110609] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2023] [Revised: 07/02/2023] [Accepted: 07/03/2023] [Indexed: 07/08/2023]
Abstract
BACKGROUND Interstitial lung abnormalities (ILAs) are associated with the risk of progression to interstitial lung diseases (ILDs). Krebs von den Lungen 6 (KL-6) and surfactant protein (SP)-A have been used as biomarkers of ILDs. In this study, we evaluated the levels of these biomarkers and identified their clinical correlations in healthy individuals to assess their usefulness in the diagnosis of ILAs. METHODS The patient samples were categorized into three groups: healthy, disease, and ILD groups. We used the automated immunoassay HISCL KL-6 and SP-A assay kits. The analytical performance evaluation involved precision, linearity, comparison, establishment of reference intervals, and determination of the cutoff points. We also analyzed the correlations between presence of abnormalities on chest radiography and computed tomography (CT) or pulmonary function test (PFT) and serum levels in the healthy group. RESULTS KL-6 and SP-A assays showed good analytical performance. The KL-6 and SP-A cutoff values were 304 U/mL and 43.5 ng/mL between the ILD and healthy groups, respectively, which were lower than the values recommended by the manufacturer. In the clinical correlations with radiological findings, SP-A values in subjects with lung abnormalities on CT scans were significantly higher than those in normal scans. There was no significant difference in KL-6 and SP-A levels among PFT patterns; however, both serum levels in the mixed pattern showed higher values than those in the other patterns. CONCLUSIONS The results revealed a positive association between increased serum levels of SP-A and KL-6 and clinical characteristics as incidental findings on chest imaging and reduced lung function.
Collapse
|
7
|
Accuracy of the New Creatinine-based Equations for Estimating Glomerular Filtration Rate in Koreans. Ann Lab Med 2023; 43:244-252. [PMID: 36544336 PMCID: PMC9791020 DOI: 10.3343/alm.2023.43.3.244] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Revised: 08/23/2022] [Accepted: 10/06/2022] [Indexed: 12/24/2022] Open
Abstract
Background New creatinine-based estimated glomerular filtration rate (eGFR) equations, including the 2021 Chronic Kidney Disease Epidemiology Collaboration (2021 CKD-EPI) and European Kidney Function Consortium (EKFC) equations, have been introduced recently. We assessed the performance of the 2021 CKD-EPI and EKFC equations in the Korean population. Methods We analyzed 1,654 Korean patients aged ≥18 years who underwent chromium-51-ethylenediamine tetraacetic acid GFR measurements (mGFR). Bias (eGFR-mGFR), root mean square error (RMSE), and proportion of eGFR within 30% of mGFR (P30) of the 2009 CKD-EPI, 2021 CKD-EPI, and EFKC equations were compared. The concordance rate between eGFR and mGFR categories was evaluated. Both eGFR and mGFR categories were classified into six groups: ≥90, 89-60, 59-45, 44-30, 29-15, and <15 mL/min/1.73 m2. Results The median bias (mL/min/1.73 m2) was 1.8 for the 2009 CKD-EPI equation, 4.8 for the 2021 CKD-EPI equation, and -0.3 for the EKFC equation. The P30 and RMSE were 78.2% and 17.0 for the 2009 CKD-EPI equation, 75.6% and 17.4 for the 2021 CKD-EPI equation, and 80.0% and 16.7 for the EKFC equation, respectively. The overall GFR category concordance rate between eGFR and mGFR was 63.4% for the 2009 CKD-EPI equation, 60.5% for the 2021 CKD-EPI equation, and 61.0% for the EKFC equation. Conclusions Among the three eGFR equations, the EKFC equation had the smallest bias and highest P30 in Koreans. The 2009 CKD-EPI equation had a lower bias than the 2021 CKD-EPI equation.
Collapse
|
8
|
Total PSA Test Performance Evaluation on Cobas Pure and Measurement System Comparison with Different Calibrators. Clin Lab 2023; 69. [PMID: 37057943 DOI: 10.7754/clin.lab.2022.220204] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/15/2023]
Abstract
BACKGROUND This study investigated the performance evaluation of total prostate specific antigen (tPSA) testing using Cobas Pure integrated solutions system (calibrated against WHO IS 96/670) and the comparison with established measurement systems with different traceability. METHODS The evaluation was performed in terms of imprecision, linearity, detection limit, and correlation with Alinity i (calibrated against WHO IS 96/670) and Unicel DxI 800 (calibrated against the manufacturer's working calibrators). RESULTS Within-laboratory reproducibility and repeatability were observed less than 1.2%. Linearity was achieved within the claimed analytical measurement range. The claimed LoB and LoD were experimentally verified. All the correlation coefficients among the assays indicated good correlation, but the significant mean bias with Unicel DxI 800 using a different calibrator were observed. CONCLUSIONS Since the tPSA calibrators against different traceability is still commercially available, our research could convey the impact of calibration on tPSA results as well as the performance information of a new assay for tPSA.
Collapse
|
9
|
Proposed Model for Evaluating Real-world Laboratory Results for Big Data Research. Ann Lab Med 2023; 43:104-107. [PMID: 36045065 PMCID: PMC9467825 DOI: 10.3343/alm.2023.43.1.104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Revised: 05/23/2022] [Accepted: 07/27/2022] [Indexed: 12/31/2022] Open
|
10
|
Intuitive Modification of the Friedewald Formula for Calculation of LDL-Cholesterol. Ann Lab Med 2023; 43:29-37. [PMID: 36045054 PMCID: PMC9467839 DOI: 10.3343/alm.2023.43.1.29] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Revised: 05/13/2022] [Accepted: 08/11/2022] [Indexed: 12/27/2022] Open
Abstract
Background High LDL-cholesterol (LDL-C) is an established risk factor for cardiovascular disease and is considered an important therapeutic target. It can be measured directly or calculated from the results of other lipid tests. The Friedewald formula is the most widely used formula for calculating LDL-C. We modified the Friedewald formula for a more accurate and practical estimation of LDL-C. Methods Datasets, including measured triglyceride, total cholesterol, HDL-cholesterol, and LDL-C concentrations were collected and assigned to derivation and validation sets. The datasets were further divided into five groups based on triglyceride concentrations. In the modified formula, LDL-C was defined as total cholesterol - HDL-cholesterol - (triglyceride/adjustment factor). For each group, the adjustment factor that minimized the difference between measured LDL-C and calculated LDL-C using modified formula was obtained. For validation, measured LDL-C and LDL-C calculated using the modified formula (LDL-CM), Friedewald formula (LDL-CF), Martin-Hopkins formula (LDL-CMa), and Sampson formula (LDL-CS) were compared. Results In the derivation set, the adjustment factors were 4.7, 5.9, 6.3, and 6.4 for the groups with triglyceride concentrations <100, 101-200, 201-300, and >300 mg/dL, respectively. In the validation set, the coefficient of determination (R2) between measured and calculated LDL-C was higher for LDL-CM than for LDL-CF (R2=0.9330 vs. 0.9206). The agreement according to the National Cholesterol Education Program Adult Treatment Panel III classification of LDL-C was 86.36%, 86.08%, 86.82%, and 86.15% for LDL-CM, LDL-CF, LDL-CMa, and LDL-CS, respectively. Conclusions We proposed a practical, improved LDL-C calculation formula by applying different factors depending on the triglyceride concentration.
Collapse
|
11
|
Association between measured or calculated small dense low-density lipoprotein cholesterol and oxidized low-density lipoprotein in subjects with or without type 2 diabetes mellitus. J Clin Lab Anal 2022; 37:e24807. [PMID: 36525335 PMCID: PMC9833976 DOI: 10.1002/jcla.24807] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Revised: 10/31/2022] [Accepted: 11/30/2022] [Indexed: 12/23/2022] Open
Abstract
BACKGROUND Small dense low-density lipoprotein (sdLDL) possesses atherogenic potential and is predicted to be susceptible to atherogenic modifications, which further increases its atherogenicity. However, studies on the association between measured or estimated sdLDL cholesterol (sdLDL-C) levels and atherogenic modification in diverse population groups are lacking. METHODS Surplus serum samples were collected from male subjects with type 2 diabetes mellitus (DM) under treatment (n = 300) and without DM (non-DM; n = 150). sdLDL and oxidized LDL (oxLDL) levels were measured using the Lipoprint LDL subfractions kit (Quantimetrix Corporation) and the Mercodia oxidized LDL competitive enzyme-linked immunosorbent assay kit (Mercodia), respectively. The estimated sdLDL-Cs were calculated from two relevant equations. The effects of sdLDL-C on oxLDL were assessed using multiple linear regression (MLR) models. RESULTS The mean (±SD) of measured sdLDL-C and oxLDL concentrations were 11.8 ± 10.0 mg/dl and 53.4 ± 14.2 U/L in the non-DM group and 0.20 ± 0.81 mg/dl and 46.0 ± 15.3 U/L in the DM group, respectively. The effects of measured sdLDL-Cs were significant (p = 0.031), whereas those of estimated sdLDL-Cs were not (p = 0.060, p = 0.116) in the non-DM group in the MLR models. The effects of sdLDL-Cs in the DM group were not significant. CONCLUSION In the general population, high level of sdLDL-C appeared to be associated with high level of oxLDL. The equation for estimating sdLDL-C developed from a general population should be applied with caution to a special population, such as patients with DM on treatment.
Collapse
|
12
|
Age Group-specific Reference Intervals for the Elecsys Anti-Müllerian Hormone Assay in Healthy Korean Women: a Nationwide Population-based Study. Ann Lab Med 2022; 42:621-629. [PMID: 35765870 DOI: 10.3343/alm.2022.42.6.621] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2021] [Revised: 03/21/2022] [Accepted: 06/07/2022] [Indexed: 11/19/2022] Open
Abstract
Background Anti-Müllerian hormone (AMH) is one of the most reliable markers of ovarian reserve. Automated AMH assays are widely used in clinical laboratories, but reference intervals for the Elecsys AMH assay for Asian populations have not yet been determined. We aimed to determine reference intervals in healthy Korean women. Methods The study included 1,450 women aged 19 to 54 years who participated in the Korea National Health and Nutrition Examination Survey between 2013 and 2016. The study participants were divided into seven 5-year age groups. AMH and progesterone concentrations were measured using Roche Elecsys assays, and bone morphogenetic protein-15 (BMP15) was genotyped for the detection of major variants. Age group-specific reference intervals for AMH were established as recommended by the CLSI EP28-A3c guidelines. Results The mean age was 37.4 years. AMH concentrations decreased with increasing age, especially after 40 years, with the median AMH decreasing from 30.9 pmol/L in participants of 19-24 years to 0.071 pmol/L in participants of 50-54 years. The mid-95 percentile AMH reference intervals decreased from 7.93-81.21 pmol/L in participants of 19-24 years to 0.07-3.86 pmol/L in participants of 50-54 years. Disease-associated BMP15 variants were not detected. Conclusions We determined Elecsys AMH assay reference intervals in healthy Korean women. The results may provide basic information for the interpretation of AMH concentrations and assessment of ovarian reserve in Korean women.
Collapse
|
13
|
Practical Considerations for Clinical Laboratories in Top-down Approach for Assessing the Measurement Uncertainty of Clinical Chemistry Analytes. Ann Lab Med 2022; 42:630-637. [PMID: 35765871 PMCID: PMC9277045 DOI: 10.3343/alm.2022.42.6.630] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2022] [Revised: 03/22/2022] [Accepted: 06/20/2022] [Indexed: 11/23/2022] Open
Abstract
Background The top-down (TD) approach using internal quality control (IQC) data is regarded a practical method for estimating measurement uncertainty (MU) in clinical laboratories. We estimated the MU of 14 clinical chemistry analytes using the TD approach and evaluated the effect of lot changes on the MU. Methods MU values were estimated using subgrouping by reagent lot changes or using the data as a whole, and both methods were compared. Reagent lot change was simulated using randomly generated data, and the mean values and MU for two IQC datasets (different QC material lots) were compared using statistical methods. Results All MU values calculated using subgrouping were lower than the total values; however, the average differences were minimal. The simulation showed that the greater the increase in the extent of the average shift, the larger the difference in MU. In IQC data comparison, the mean values and MU exhibited statistically significant differences for most analytes. The MU calculation methods gave rise to minimal differences, suggesting that IQC data in clinical laboratories show no significant shift. However, the simulation results demonstrated that notable differences in the MU can arise from significant variations in IQC results before and after a reagent lot change. Additionally, IQC material lots should be treated separately when IQC data are collected for MU estimation. Conclusions Lot changes in IQC data are a key factor affecting MU estimation and should not be overlooked during MU estimation.
Collapse
|
14
|
Strategies to shorten turnaround time in outpatient laboratory. J Clin Lab Anal 2022; 36:e24665. [PMID: 36036784 PMCID: PMC9550964 DOI: 10.1002/jcla.24665] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2022] [Revised: 08/04/2022] [Accepted: 08/06/2022] [Indexed: 11/09/2022] Open
Abstract
BACKGROUND Turnaround time (TAT) is one of the most important indicators of laboratory quality. For the outpatient routine chemistry tests whose results are checked by clinicians on the same day, we set a quality goal that >90% of these samples should be reported within 60 min. As more than 20% of the samples failed to achieve this goal in 2020, we introduced an additional autoanalyzer and a real-time monitoring system to improve this rate. METHODS As the TAT of the pre-analytical phase is the greatest contributor to TAT, we divided it into sampling, sample transport, and sample preparation times. An additional autoanalyzer was introduced, and its effect on TAT improvement was evaluated with the TAT data of June and July 2020. A real-time monitoring system was introduced to sort delayed samples, and its effect was assessed with the TAT data of June and July 2021. TAT data from December 2019 to January 2020 were set as baseline controls. RESULTS The preparation time comprised the largest proportion of TAT. Although there was a slight decrease in overall TAT after the introduction of the above two strategies, the target TAT achievement rate increased significantly from 78.5% to 88.7% (p < 0.001). CONCLUSIONS We checked the cause of TAT prolongation and introduced new strategies to improve it. The addition of an autoanalyzer per se was not so effective but was better when combined with the real-time monitoring system. Such strategies would increase the quality of the laboratory services.
Collapse
|
15
|
Abstract No. 521 Robot-assisted transarterial chemoembolization using “operation bed mounted master-slave robot system” for the treatment of hepatocellular carcinoma: pilot study to evaluate the safety and efficiency. J Vasc Interv Radiol 2022. [DOI: 10.1016/j.jvir.2022.03.503] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
|
16
|
RNA Sequencing for Elucidating an Intronic Variant of Uncertain Significance ( SDHD c.314+3A>T) in Splicing Site Consensus Sequences. Ann Lab Med 2022; 42:376-379. [PMID: 34907111 PMCID: PMC8677484 DOI: 10.3343/alm.2022.42.3.376] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2021] [Revised: 09/02/2021] [Accepted: 11/29/2021] [Indexed: 11/19/2022] Open
|
17
|
W250 Accuracy evaluation of automated electrochemiluminescence immunoassay for everolimus and sirolimus compared to liquid chromatography-tandem mass spectrometry. Clin Chim Acta 2022. [DOI: 10.1016/j.cca.2022.04.491] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
18
|
M041 Comparability of selected assays on COBAS pure integrated solutions under routine-like conditions. Clin Chim Acta 2022. [DOI: 10.1016/j.cca.2022.04.332] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
19
|
M104 Application and modification of reference change values for delta checks in clinical laboratory. Clin Chim Acta 2022. [DOI: 10.1016/j.cca.2022.04.202] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
20
|
M246 Estimated mean recovery of two LDL cholesterol homogeneous methods by non-HDL particle size distribution. Clin Chim Acta 2022. [DOI: 10.1016/j.cca.2022.04.465] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
21
|
RNA Sequencing Provides Evidence for Pathogenicity of a Novel CHEK2 Splice Variant (C.1009-7T>G). Ann Lab Med 2022; 42:380-383. [PMID: 34907112 PMCID: PMC8677473 DOI: 10.3343/alm.2022.42.3.380] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2021] [Revised: 09/22/2021] [Accepted: 11/26/2021] [Indexed: 11/19/2022] Open
|
22
|
M109 Monitoring of the proportion of unacceptable specimen for laboratory quality improvement. Clin Chim Acta 2022. [DOI: 10.1016/j.cca.2022.04.207] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
23
|
T115 Hematocrit is a predictive marker for inaccurate interpretation of arterial blood gas analysis caused by inadequate sample mixing. Clin Chim Acta 2022. [DOI: 10.1016/j.cca.2022.04.583] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
24
|
Effect of Outlier Elimination on the 99th Percentile Upper Reference Limits of High-Sensitivity Cardiac Troponin I Assays Based on a Strictly Selected Healthy Reference Population. Ann Lab Med 2022; 42:331-341. [PMID: 34907103 PMCID: PMC8677476 DOI: 10.3343/alm.2022.42.3.331] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2021] [Revised: 06/13/2021] [Accepted: 11/30/2021] [Indexed: 11/19/2022] Open
Abstract
Background We established high-sensitivity cardiac troponin I (hsTnI) 99th percentile upper reference limits (URLs) for the Centaur XPT High-Sensitivity Troponin I assay (Centaur hsTnI; Siemens, Erlangen, Germany) and Atellica IM High-Sensitivity Troponin I assay (Atellica hsTnI; Siemens) and assessed the effect of outlier elimination. Methods The reference population comprised 380 men and 387 women, satisfying the strict systematic reference population criteria. After reference population verification by the N-terminal pro-B-type natriuretic peptide (NT-proBNP) assay, 99th percentile URLs for Centaur hsTnI and Atellica hsTnI were calculated before and after outlier elimination. Results The 99th percentile URL for Centaur hsTnI was 60.4 (men, 74.7; women, 57.5) ng/L and that for Atellica hsTnI was 59.6 (men, 75.2; women, 55.1) ng/L. After the elimination of 61 (8.0%) outlier samples in Centaur hsTnI and 58 (7.6%) in Atellica hsTnI, the 99th percentile URLs were 13.5 ng/L (men, 15.3 ng/L; women, 11.9 ng/L) and 13.4 ng/L (men, 15.5 ng/L; women, 12.9 ng/L), respectively, significantly lower than those before outlier elimination. The CVs at the 99th percentile URLs were 5.2% and 3.5%, respectively. The measurable fractions among the reference population were 91.5% and 93.4%, respectively. Performance evaluation of Atellica B-type natriuretic peptide (BNP), Atellica NT-proBNP, Centaur hsTnI, and Atellica hsTnI showed outstanding results. Conclusions The Korean hsTnI 99th percentile URLs calculated in this study were significantly lower after outlier elimination than before. Centaur hsTnI and Atellica hsTnI meet the "Guideline acceptable" and "Level 3 (second generation, high sensitivity)" requirements, satisfying international standards.
Collapse
|
25
|
Abstract
Objective This study aimed to examine the intra- and interlaboratory variations of cycle threshold (Ct) values using the nationwide proficiency testing for SARS-CoV-2. Methods Triplicated strong-positive contrived samples duplicated weak-positive contrived samples, and 2 negative samples were transported to participating laboratories in October 2021. Results A total of 232 laboratories responded. All except 4 laboratories correctly answered. Six false-negative results, including 2 false-negatives with Ct values beyond the threshold and 1 clerical error, were noted from weak-positive samples. Intralaboratory variations of Ct values of weak-positive and strong-positive samples were not acceptable (Ct > 1.66) in 17 and 7 laboratories, respectively. High interlaboratory variations of Ct values (up to 7 cycles) for the 2 commonly used polymerase chain reaction (PCR) reagents were observed. Conclusion The overall qualitative performance was acceptable; intralaboratory variation was acceptable. However, interlaboratory variations of Ct values were remarkable even when the same PCR reagents were used.
Collapse
|
26
|
Semiquantitative Analysis of the Results of an Image-Based Urine Sediment Analyzer Considering the Preanalytical Factors. Clin Lab 2021; 67. [PMID: 34758221 DOI: 10.7754/clin.lab.2021.210105] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
BACKGROUND Automated microscopic platforms are increasingly used in clinical laboratories for rapid analysis of samples. However, it is important to present the results quantitatively or semiquantitatively because automated platforms use various technologies for analysis as well as different sediment preparation methods. The results of cell counting using an on screen image review program for the cobas u 701 analyzer (Roche Diagnostics Interna-tional, Rotkreuz, Switzerland) differed from those obtained by manual microscopic examination (MME). This study was performed to investigate the difference of results among analyzer, on-screen image review and MME. METHODS Freshly collected urine specimens from outpatients were used. We calculated the mean, standard deviation, and 95% confidence interval for red and white blood cell (RBC/WBC) quantitative results obtained using the cobas u 701 analyzer. These results were compared to those obtained by manual counting. RBC and WBC counts determined with the cobas u 701 analyzer were compared to those obtained by MME per unit field. RESULTS The semiquantitative results of MME were graded as 0 - 2, 3 - 5, 6 - 10, 11 - 20, 21 - 30, and many or numerous cells/high power field (HPF). The RBC and WBC counts determined by image analyses showed the tendency to be one grade higher than those from MME in the range of 3 to 5/HPF to many/HPF. The results of nearly all samples with 0 - 2/HPF and numerous/HPF for RBC and WBC counts were consistent with the grade found by MME. CONCLUSIONS The one-grade difference may have been caused by the differences of preanalytical factors in the sample volume, centrifugal force, urine concentration ratio, or sediment volume/area of the slide. When reporting the results of image analyses, RBC and WBC counts should be raised by one grade to compensate for MME. Each laboratory needs to verify the on-screen review of images corresponding to the microscopic field of view according to the clinical laboratory's specific preanalytical practices.
Collapse
|
27
|
Immunosuppressive Drug Measurement by Liquid Chromatography Coupled to Tandem Mass Spectrometry: Interlaboratory Comparison in the Korean Clinical Laboratories. Ann Lab Med 2021; 41:268-276. [PMID: 33303711 PMCID: PMC7748092 DOI: 10.3343/alm.2021.41.3.268] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Revised: 06/12/2020] [Accepted: 11/17/2020] [Indexed: 11/19/2022] Open
Abstract
Background Liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) is increasingly used for immunosuppressive drug tests. However, most LC-MS/MS tests are laboratory-developed and their agreement is unknown in different Korean laboratories. This interlaboratory comparison study evaluated test reproducibility and identified potential error sources. Methods Test samples containing three concentrations of tacrolimus, sirolimus, everolimus, cyclosporine, and mycophenolic acid were prepared by pooling surplus samples from patients undergoing routine therapeutic drug monitoring and tested in duplicate in the participating 10 clinical laboratories. Reconstitution and storage experiments were conducted for the commonly used commercial calibrator set. The robust estimators of reproducibility parameters were calculated. Spearman’s rank correlation coefficient (rho, ρ) was used to evaluate the correlation between drugs. Multiple linear regression was used to determine whether the experimental conditions alter the calibration curves. Results The reproducibility coefficient of variation exceeded 10% only for sirolimus concentrations 1 and 2 (10.8% and 12.5%, respectively) and everolimus concentrations 1 and 2 (12.3% and 11.4%, respectively). The percent difference values showed weak correlations between sirolimus and everolimus (ρ=0.334, P =0.175). The everolimus calibration curve slope was significantly altered after reconstitution following prolonged 5°C storage (P =0.015 for 14 days; P =0.025 for 28 days); the expected differences at 6 ng/mL were 0.598% for 14 days and 0.384% for 28 days. Conclusions LC-MS/MS test reproducibility for immunosuppressive drugs seems to be good in the Korean clinical laboratories. Continuous efforts are required to achieve test standardization and harmonization, especially for sirolimus and everolimus.
Collapse
|
28
|
Schemes and Performance Evaluation Criteria of Korean Association of External Quality Assessment (KEQAS) for Improving Laboratory Testing. Ann Lab Med 2021; 41:230-239. [PMID: 33063686 PMCID: PMC7591290 DOI: 10.3343/alm.2021.41.2.230] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2020] [Revised: 06/07/2020] [Accepted: 09/19/2020] [Indexed: 12/11/2022] Open
Abstract
External quality assessment (EQA) is important for evaluating clinical laboratories and enhancing their testing quality. EQA schemes are variable; thus, it is crucial that the EQA organizers share their experiences to continuously improve the EQA scheme. The Korean Association of External Quality Assessment Service (KEQAS) has been the leading, authorized EQA institute for the standardization and quality management of laboratory testing in Korean medical institutions since 1976. The EQA scheme underwent a major change in 2016, and the number of EQA programs increased significantly since then. The key changes implemented in EQA scheme include a fully computerized assessment to accelerate feedback and unification of the testing and reporting methods. We provide an overview of the EQA schemes and performance evaluation criteria of the KEQAS and suggest directions for achieving the global harmonization of EQA.
Collapse
|
29
|
Establishment of Pediatric Reference Intervals for Routine Laboratory Tests in Korean Population: A Retrospective Multicenter Analysis. Ann Lab Med 2021; 41:155-170. [PMID: 33063677 PMCID: PMC7591287 DOI: 10.3343/alm.2021.41.2.155] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2020] [Revised: 04/08/2020] [Accepted: 09/08/2020] [Indexed: 12/24/2022] Open
Abstract
Background Reference intervals defined for adults or children of other ethnicities cannot be applied in the evaluation of Korean pediatric patients. Pediatric reference intervals are difficult to establish because children are in their growing stage and their physiology changes continuously. We aimed to establish reference intervals for routine laboratory tests for Korean pediatric patients through retrospective multicenter data analysis. Methods Preoperative laboratory test results from 1,031 pediatric patients aged 0 month–18 years who underwent minor surgeries in four university hospitals were collected. Age- and sex-specific reference intervals for routine laboratory tests were defined based on the Clinical and Laboratory Standards Institute (CLSI) EP28-A3c guidelines. Results The pediatric reference intervals determined in this study were different from existing adult reference intervals and pediatric reference intervals for other ethnicities. Most tests required age-specific partitioning, and some of those required sex-specific partitioning for at least one age-partitioned subgroup. Erythrocyte sedimentation rate, monocyte percentage, basophil percentage, activated partial thromboplastin time, glucose, cholesterol, albumin, bilirubin, chloride, and C-reactive protein did not show any difference between age- or sex-partitioned subgroups. Conclusions We determined Korean pediatric reference intervals for hematology, coagulation, and chemistry tests by indirect sampling based on medical record data from multiple institutions. These reference intervals would be valuable for clinical evaluations in the Korean pediatric population.
Collapse
|
30
|
Standardization Status of Total Cholesterol Concentration Measurement: Analysis of Korean External Quality Assessment Data. Ann Lab Med 2021; 41:366-371. [PMID: 33536354 PMCID: PMC7884189 DOI: 10.3343/alm.2021.41.4.366] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2020] [Revised: 09/07/2020] [Accepted: 01/20/2021] [Indexed: 11/19/2022] Open
Abstract
Background Total cholesterol concentration measurement is important in the diagnosis of dyslipidemia and evaluation of cardiovascular disease risk factors. Measurement reliability for obtaining an accurate total cholesterol concentration requires procedure standardization. We evaluated the standardization status for total cholesterol concentration measurement through Korean external quality assessment (EQA) data analysis. Methods This study involved 1,670 laboratories that participated in the EQA of total cholesterol concentration measurements in 2019 for 32 products from different manufacturers. The target concentrations of three quality control (QC) materials (samples A, B, and C) were measured using the reference method and compared with EQA data. The performance criteria for total cholesterol concentration measurement were based on the National Cholesterol Education Program guidelines, with ±3% inaccuracy. Results The target values and inaccuracies of the QC material based on the reference method measurements were 254.65±7.64, 108.30±3.25, and 256.29±7.69 mg/dL (6.59±0.20, 2.80±0.08, and 6.63±0.20 mmol/L) for samples A, B, and C, respectively. The performance criteria were not met in 42.7% laboratories for sample A, 68.4% of laboratories for sample B, and 38.0% laboratories for sample C. Conclusions Despite significant efforts to accurately measure total cholesterol concentrations, further actions are needed for measurement standardization. Manufacturers reporting values that differ from target values should check calibrator traceability; additional efforts to accurately measure total cholesterol concentrations are required for laboratories that use products from these manufacturers.
Collapse
|
31
|
Recent Trends in Creatinine Assays in Korea: Long-Term Accuracy-Based Proficiency Testing Survey Data by the Korean Association of External Quality Assessment Service (2011-2019). Ann Lab Med 2021; 41:372-379. [PMID: 33536355 PMCID: PMC7884186 DOI: 10.3343/alm.2021.41.4.372] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Revised: 08/17/2020] [Accepted: 01/11/2021] [Indexed: 11/19/2022] Open
Abstract
Background Accurate serum creatinine (Cr) concentration measurement is essential for evaluating kidney function. In 2011, the Korean Association of External Quality Assessment Service (KEQAS) launched an accuracy-based Cr proficiency testing (ABCr PT) survey. We analyzed long-term data of the KEQAS ABCr PT survey collected between 2011 and 2019 to assess recent trends in Cr assays in Korea. Methods The ABCr PT survey including three commutable fresh-frozen serum samples was performed twice a year. The target Cr concentration was assigned using isotope-dilution mass spectrometry. We analyzed data obtained from the participating laboratories, calculated the yearly bias, and evaluated bias trends for the major reagents and instruments. Outliers were excluded from all analysis. Results The mean percentage bias based on the total data of all participating laboratories was 10.8% in the 2011-A survey and 0.2% in 2019-B survey. Bias for the major reagents and instruments differed depending on the manufacturer. Enzymatic assays generally showed desirable bias ranging from –3.9% to 3.2% at all Cr concentrations and lower interlaboratory variability than non-enzymatic assays (enzymatic vs. non-enzymatic, 3.3%–7.2% vs. 6.3%–9.1%). Conclusions Although the mean percentage bias of Cr assays tends to decrease over time, it is necessary to continuously strive to improve Cr assay accuracy, especially at low concentrations.
Collapse
|
32
|
Status of Four Trace Elements in Elderly Patients with Online Hemodiafiltration. Clin Lab 2021; 67. [PMID: 34107631 DOI: 10.7754/clin.lab.2020.201026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
BACKGROUND Essential trace elements play key roles in multiple biological systems, and hemodialysis patients are at risk for deficiency of essential trace elements. The aim of the study was to assess the essential element status in end stage renal disease patients undergoing online hemodiafiltration (online HDF) in outpatient dialysis clinic. METHODS A total of 28 Korean patients with regular online HDF were included. Blood samples were collected before and after one HDF session, and serum concentrations of zinc, copper, selenium, and manganese were simulta-neously measured by inductively coupled plasma mass spectrometry. RESULTS Selenium, zinc, copper deficiencies were observed in 71.4%, 35.8%, and 21.4%, compared with the reference range. No patients revealed manganese deficiency. After the HDF, the post-HDF level significantly increased in all trace elements, compared with the pre-HDF (11.2% for selenium, 10.7% for copper, and 6.6% for zinc). However, 50% patients were still deficient for selenium at the post-HDF. CONCLUSIONS Our data suggest that the patients undergoing online HDF are at an increased risk of trace element deficiency, especially for selenium.
Collapse
|
33
|
Prostate cancer detection, tolerability and safety of transperineal prostate biopsy under local-anaesthesia versus standard transrectal biopsy in biopsy-naïve men: A pragmatic, parallel group, randomized-controlled study. Eur Urol 2021. [DOI: 10.1016/s0302-2838(21)01372-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
34
|
CP01.06 Veterans Affairs Insurance Disparities for Metastatic Lung Cancer in the Hawaiian Islands. J Thorac Oncol 2021. [DOI: 10.1016/j.jtho.2020.10.047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
35
|
Application and optimization of reference change values for Delta Checks in clinical laboratory. J Clin Lab Anal 2020; 34:e23550. [PMID: 32862477 PMCID: PMC7755783 DOI: 10.1002/jcla.23550] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2020] [Revised: 07/23/2020] [Accepted: 08/06/2020] [Indexed: 11/12/2022] Open
Abstract
BACKGROUND Delta check is a patient-based QC tool for detecting errors by comparing current and previous test results of patient. Reference change value (RCV) is adopted in guidelines as method for delta check, but the performance is not verified. We applied RCV-based delta check method to patients' data and modified for application. MATERIALS AND METHODS Reference change value were calculated using results of internal QC materials and biological variation data. Test results of 17 analytes in inpatients, outpatients, and health examination recipients were collected. The detection rates of currently used delta check method and those of RCV-based method were compared, and the methods were modified. RESULTS Reference change value-based method had higher detection rates compared to conventional method. Applied modifications reduced detection rates. Removing the pairs of results within reference interval reduced detection rates (0.42% ~ 10.92%). When RCV was divided by time interval, the detection rates were similar to prior rates in outpatients (0.19% ~ 1.34%). Using RCV multiplied by twice the upper limit of reference value as cutoff reduced the detection rate (0.07% ~ 1.58%). CONCLUSIONS Reference change value is a robust criterion for delta check and included in clinical laboratory practice guideline. However, RCV-based method generates high detection rates which increase workload. It needs modification for use in clinical laboratories.
Collapse
|
36
|
Abstract
External quality assessment (EQA) is essential for ensuring reliable test results, especially when laboratories are using assays authorized for emergency use for newly emerging pathogens. We developed an EQA panel to assess the quality of real-time reverse transcription PCR assays being used in South Korea to detect severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). With the participation of 23 public health organization laboratories and 95 nongovernmental laboratories involved in SARS-CoV-2 testing, we conducted qualitative and semiquantitative performance assessments by using pooled respiratory samples containing different viral loads of SARS-CoV-2 or human coronavirus OC43. A total of 110 (93.2%) laboratories reported correct results for all qualitative tests; 29 (24.6%) laboratories had >1 outliers according to cycle threshold values. Our EQA panel identified the potential weaknesses of currently available commercial reagent kits. The methodology we used can provide practical experience for those planning to conduct evaluations for testing of SARS-CoV-2 and other emerging pathogens in the future.
Collapse
|
37
|
The Frequency of Discordant Variant Classification in the Human Gene Mutation Database: A Comparison of the American College of Medical Genetics and Genomics Guidelines and ClinVar. Lab Med 2020; 52:250-259. [PMID: 32926152 DOI: 10.1093/labmed/lmaa072] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023] Open
Abstract
OBJECTIVE Discordant variant classifications among public databases is one of the well-documented limitations when interpreting the pathogenicity of variants. The aim of this study is to investigate the level of germline variant misannotation from the Human Gene Mutation Database (HGMD) and the annotation concordance between databases. METHODS We used a total of 188,106 classified variants (disease-causing mutations [n = 179,454] and polymorphisms [n = 8652]) in 6466 genes from the HGMD. All variants were reanalyzed based on the American College of Medical Genetics and Genomics (ACMG) guidelines and compared to ClinVar database variants. RESULTS When variants were classified based on the ACMG guidelines, misclassification was observed in 3.47% (2289/65,896) of variants. The overall concordance between HGMD and ClinVar was 97.62% (52,499/53,780) of variants studied. CONCLUSION Variants in databases must be used with caution when variant pathogenicity is interpreted. This study reveals the frequency of misannotation of the HGMD variants and annotation concordance between databases in depth.
Collapse
|
38
|
A Novel Splice Variant (c.438T>A) of APC, Suspected by Family History and Confirmed by RNA Sequencing. Ann Lab Med 2020; 41:123-125. [PMID: 32829589 PMCID: PMC7443526 DOI: 10.3343/alm.2021.41.1.123] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2020] [Revised: 04/21/2020] [Accepted: 07/17/2020] [Indexed: 11/19/2022] Open
|
39
|
Performance evaluation of an amplicon-based next-generation sequencing panel for BRCA1 and BRCA2 variant detection. J Clin Lab Anal 2020; 34:e23524. [PMID: 32812259 PMCID: PMC7755770 DOI: 10.1002/jcla.23524] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2020] [Revised: 07/16/2020] [Accepted: 07/20/2020] [Indexed: 12/13/2022] Open
Abstract
BACKGROUND As next-generation sequencing (NGS) technology matures, various amplicon-based NGS tests for BRCA1/2 genotyping have been introduced. This study was designed to evaluate an NGS test using a newly released amplicon-based panel, AmpliSeq for Illumina BRCA Panel (AmpliSeq panel), for detection of clinically significant BRCA variants, and to compare it to another amplicon-based NGS test confirmed by Sanger sequencing. METHODS We reviewed BRCA test results done by NGS using the TruSeq Custom Amplicon kit from patients suspected of hereditary breast/ovarian cancer syndrome (HBOC) in 2018. Of those, 96 residual samples with 100 clinically significant variants were included in this study using predefined criteria: 100 variants were distributed throughout the BRCA1 and BRCA2 genes. All target variants were confirmed by Sanger sequencing. Duplicate NGS testing of these samples was performed using the AmpliSeq panel, and the concordance of results from the two amplicon-based NGS tests was assessed. RESULTS Ninety-nine of 100 variants were detected in duplicate BRCA1/2 genotyping using the AmpliSeq panel (sensitivity, 99%; specificity, 100%). In the discordant case, one variant (BRCA1 c.3627dupA) was found only in repeat 1, but not in repeat 2. Automated nomenclature of all variants, except for two indel variants, was in consensus with Human Genome Variation Society nomenclature. CONCLUSION Our findings confirm that the analytic performance of the AmpliSeq panel is satisfactory, with high sensitivity and specificity.
Collapse
|
40
|
Preparedness and Rapid Implementation of External Quality Assessment Helped Quickly Increase COVID-19 Testing Capacity in the Republic of Korea. Clin Chem 2020; 66:979-981. [PMID: 32321159 PMCID: PMC7188181 DOI: 10.1093/clinchem/hvaa097] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/16/2020] [Indexed: 11/12/2022]
|
41
|
Transrectal vs. transperineal prostate biopsy under local anaesthesia: Prospective comparative analysis of cancer detection, safety and tolerability using patient-reported outcome measures at a single centre. EUR UROL SUPPL 2020. [DOI: 10.1016/s2666-1683(20)34175-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022] Open
|
42
|
Are Genetic Variants Associated with the Location of Cerebral Arterial Lesions in Stroke Patients? Cerebrovasc Dis 2020; 49:262-268. [PMID: 32526736 DOI: 10.1159/000508301] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2019] [Accepted: 04/28/2020] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND Genetic variants may play a role in determining the location of cerebral atherosclerosis. We aimed to investigate the association between RNF213, MMP2, and genetic polymorphisms linked to vascular tortuosity with the location of cerebral arterial atherosclerosis. METHODS A prospective case-control study was conducted on patients with ischemic stroke and age- and sex-matched stroke-free controls. The stroke patients were categorized into those with intracranial artery atherosclerosis (ICAS), extracranial artery atherosclerosis (ECAS), and small vessel occlusion (SVO). Six single nucleotide polymorphisms (SNPs) including rs2118181 (FBN1), rs2179357 (SLC2A10), rs1036095 (TGFBR2), rs243865 (MMP2), rs1800470 (TGFB1), and rs112735431 (RNF213) were analyzed with the TaqMan Genotyping Assay, and the distribution of genotypes across groups was compared. RESULTS None of the 6 SNPs were associated with stroke on comparing the 449 stroke patients (71 with ECAS, 169 with ICAS, and 209 with SVO) to the 447 controls. In the subgroup analysis, the adjusted odds ratios (aORs) for age and sex indicated a significant association between rs112735431 and ICAS in the allele comparison analysis and in the additive and dominant model analyses. rs112735431 was associated with anterior circulation involvement and increased burden of cerebral atherosclerosis. rs2179357 was significantly associated with ICAS in the recessive model analysis, and rs1800470 was significantly associated with ECAS in the recessive model analysis when compared to controls. CONCLUSION rs112735431 was associated with ICAS and increased atherosclerosis burden in Korean stroke patients. Further studies are needed to elucidate the role of rs112735431 and to confirm the association of rs2179357 and rs1800470 with cerebral atherosclerosis.
Collapse
|
43
|
The New Diagnosis-Related Group Reimbursement System and Laboratory Test Quality in Korea: Analysis of External Quality Assessment Results. Healthcare (Basel) 2020; 8:E127. [PMID: 32392746 PMCID: PMC7349770 DOI: 10.3390/healthcare8020127] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2020] [Revised: 04/20/2020] [Accepted: 05/01/2020] [Indexed: 12/31/2022] Open
Abstract
Korea introduced a new diagnosis-related group (NDRG), which is a mixed-bundle reimbursement system. We evaluated the effects of NDRGs on laboratory test quality by analyzing data over three years (2016-2018) from the Korean Association of External Quality Assessment Service (KEQAS). A total of 42 NDRG-participating hospitals (CASE), 84 non-participating similar size-hospitals (CON-1), and 42 tertiary hospitals (CON-2) were included. We assumed the proportion of KEQAS results with a larger than 2 standard deviation index (SDI) to be a bad laboratory quality marker (BLQM). CASE BLQMs were lower than CON-1 BLQMs for more than 2 years in alkaline phosphatase (ALP), alanine aminotransferase (ALT), chloride, glucose, sodium, and total protein, and higher in creatinine. CASE BLQMs were higher than CON-2 BLQMs for more than 2 years in ALP, chloride, creatinine, glucose, lactate dehydrogenase (LDH), phosphorus, potassium, sodium, total calcium, total cholesterol, triglyceride, and uric acid. Mean SDIs for general chemistry tests were not significantly different depending on NDRG participation. However, the NDRG is currently a pilot program that compensates the amount of each institution's reimbursement based on the fee-for-service system, and most participants were public hospitals. Thus, the effects of NDRGs on laboratory test quality should be re-evaluated after the NDRG program has stabilized and more private hospitals are participating.
Collapse
|
44
|
Identification of a Novel Splice Variant (c.423-8A>G) of APC by RNA Sequencing. Ann Lab Med 2020; 40:345-347. [PMID: 32067438 PMCID: PMC7054688 DOI: 10.3343/alm.2020.40.4.345] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2019] [Revised: 10/02/2019] [Accepted: 01/14/2020] [Indexed: 11/19/2022] Open
|
45
|
GeneReader NGS System Is a Useful Sequencing Platform for Clinical Testing of BRCA1 and BRCA2. ANNALS OF CLINICAL AND LABORATORY SCIENCE 2020; 50:107-118. [PMID: 32161019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Although next-generation sequencing (NGS) is widely used for BRCA1/2 sequencing analysis, it involves a fragmented workflow along with complex bioinformatic analysis and interpretation. In this study, the performance characteristics and workflow of the GeneReader NGS System (QIAGEN), including BRCA1/2 sequencing, were evaluated. For BRCA1/2 genetic testing, we conducted library preparation, emulsion PCR, and sequencing. QCI Analyze software was used for read alignment, quality control, variant calling, and clinical report generation. GeneReader and Sanger sequencing utilized 63 patients with breast or ovarian cancer for comparison. Reproducibility, precision, variant calling, turnaround time, and hands-on time were evaluated. The read percentage in the on-target regions was 90.5%. More than 99.99% of target regions showed read depths ≥100x. Variants generated from GeneReader showed 100% accuracy compared to the Sanger sequencing results. Annotation with GeneReader showed >99.8% concordance with HGVS nomenclature. Single-nucleotide variations and indel variants showed 100% calling reproducibility; the precision for variant frequency showed a 0.3-3.6% coefficient of variation. Most processes involved hands-off time (3714 min, 88.6% of total run time). The GeneReader NGS System for BRCA1 and BRCA2 testing showed good analytical performance and a short hands-on time. Because of its integrated sample preparation for bioinformatic interpretation, this system is practical for clinical laboratories.
Collapse
|
46
|
PD01.20 Medicaid Outcome Inequalities in Small Cell Lung Cancer. J Thorac Oncol 2019. [DOI: 10.1016/j.jtho.2019.09.056] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
47
|
Association between kidney function, proteinuria and the risk of kidney cancer: A nationwide cohort study involving 10 million participants. Ann Oncol 2019. [DOI: 10.1093/annonc/mdz425] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
48
|
P1.20 Metabolic Responses to Metformin in Early-Stage NSCLC Treated with Definitive Radiotherapy: Results of a Phase II Trial. J Thorac Oncol 2019. [DOI: 10.1016/j.jtho.2019.09.077] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
49
|
Clinical implication of multiplex IHC and serologic biomarkers on hyperprogression in NSCLC patients receiving immune checkpoint blockers in real world. Ann Oncol 2019. [DOI: 10.1093/annonc/mdz260.033] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
50
|
Use of Liquid Chromatography-Tandem Mass Spectrometry for Clinical Testing in Korean Laboratories: a Questionnaire Survey. Ann Lab Med 2019; 39:447-453. [PMID: 31037863 PMCID: PMC6502944 DOI: 10.3343/alm.2019.39.5.447] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2018] [Revised: 01/30/2019] [Accepted: 04/08/2019] [Indexed: 11/30/2022] Open
Abstract
BACKGROUND The use of liquid chromatography-tandem mass spectrometry (LC-MS/MS) has substantially increased in clinical laboratories worldwide. To assess the status of clinical LC-MS/MS testing in Korean laboratories, a questionnaire survey was performed by the Clinical Mass Spectrometry Research Committee of the Korean Society of Clinical Chemistry. METHODS The questionnaire was distributed to 19 clinical laboratories performing clinical LC-MS/MS from April to May 2018. It asked about general characteristics of the laboratory and commonly utilized clinical LC-MS/MS tests: newborn screening, tacrolimus test, vitamin D test, and plasma metanephrine test. Frequency analysis and other statistical analyses were performed. RESULTS A total of 17 laboratories responded. The median number of LC-MS/MS instruments, laboratory medicine physicians, and technicians in each laboratory was three, one, and two, respectively. Nine laboratory directors had >10 years of experience with clinical LC-MS/MS. For each LC-MS/MS test, at least two concentrations of QC materials were measured every 24 hours during clinical testing, and all laboratories used QC acceptability criteria based on their established QC means and SDs. All laboratories participated in an external quality assessment program. However, there was inter-laboratory variability in sample preparation methods, instruments, reagents, internal standards, and calibrators. CONCLUSIONS LC-MS/MS has been successfully introduced in Korean clinical laboratories and is used within a quality framework. Further efforts for harmonization on a nationwide basis could facilitate the widespread use of LC-MS/MS.
Collapse
|