1
|
Garty G, Xu Y, Elliston C, Marino SA, Randers-Pehrson G, Brenner DJ. Mice and the A-Bomb: Irradiation Systems for Realistic Exposure Scenarios. Radiat Res 2017; 187:465-475. [PMID: 28211757 DOI: 10.1667/rr008cc.1] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Validation of biodosimetry assays is normally performed with acute exposures to uniform external photon fields. Realistically, exposure to a radiological dispersal device or reactor leak will include exposure to low dose rates and likely exposure to ingested radionuclides. An improvised nuclear device will likely include a significant neutron component in addition to a mixture of high- and low-dose-rate photons and ingested radionuclides. We present here several novel irradiation systems developed at the Center for High Throughput Minimally Invasive Radiation Biodosimetry to provide more realistic exposures for testing of novel biodosimetric assays. These irradiators provide a wide range of dose rates (from Gy/s to Gy/week) as well as mixed neutron/photon fields mimicking an improvised nuclear device.
Collapse
Affiliation(s)
- Guy Garty
- a Radiological Research Accelerator Facility, Columbia University, Irvington, New York 10533; and
| | - Yanping Xu
- a Radiological Research Accelerator Facility, Columbia University, Irvington, New York 10533; and
| | - Carl Elliston
- b Center for Radiological Research, Columbia University, New York, New York 10032
| | - Stephen A Marino
- a Radiological Research Accelerator Facility, Columbia University, Irvington, New York 10533; and
| | - Gerhard Randers-Pehrson
- a Radiological Research Accelerator Facility, Columbia University, Irvington, New York 10533; and
| | - David J Brenner
- b Center for Radiological Research, Columbia University, New York, New York 10032
| |
Collapse
|
2
|
Abstract
The Radiological Research Accelerator Facility (RARAF) is in its 50th year of operation. It was commissioned on April 1, 1967 as a collaboration between the Radiological Research Laboratory (RRL) of Columbia University, and members of the Medical Research Center of Brookhaven National Laboratory (BNL). It was initially funded as a user facility for radiobiology and radiological physics, concentrating on monoenergetic neutrons. Facilities for irradiation with MeV light charged particles were developed in the mid-1970s. In 1980 the facility was relocated to the Nevis Laboratories of Columbia University. RARAF now has seven beam lines, each having a dedicated irradiation facility: monoenergetic neutrons, charged particle track segments, two charged particle microbeams (one electrostatically focused to <1 μm, one magnetically focused), a 4.5 keV soft X-ray microbeam, a neutron microbeam, and a facility that produces a neutron spectrum similar to that of the atomic bomb dropped at Hiroshima. Biology facilities are available on site within close proximity to the irradiation facilities, making the RARAF very user friendly.
Collapse
Affiliation(s)
- Stephen A Marino
- Radiological Research Accelerator Facility, Columbia University, Irvington, New York 10533
| |
Collapse
|
3
|
Xu Y, Randers-Pehrson G, Turner HC, Marino SA, Geard CR, Brenner DJ, Garty G. Accelerator-Based Biological Irradiation Facility Simulating Neutron Exposure from an Improvised Nuclear Device. Radiat Res 2015; 184:404-10. [PMID: 26414507 DOI: 10.1667/rr14036.1] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
We describe here an accelerator-based neutron irradiation facility, intended to expose blood or small animals to neutron fields mimicking those from an improvised nuclear device at relevant distances from the epicenter. Neutrons are generated by a mixed proton/deuteron beam on a thick beryllium target, generating a broad spectrum of neutron energies that match those estimated for the Hiroshima bomb at 1.5 km from ground zero. This spectrum, dominated by neutron energies between 0.2 and 9 MeV, is significantly different from the standard reactor fission spectrum, as the initial bomb spectrum changes when the neutrons are transported through air. The neutron and gamma dose rates were measured using a custom tissue-equivalent gas ionization chamber and a compensated Geiger-Mueller dosimeter, respectively. Neutron spectra were evaluated by unfolding measurements using a proton-recoil proportional counter and a liquid scintillator detector. As an illustration of the potential use of this facility we present micronucleus yields in single divided, cytokinesis-blocked human peripheral lymphocytes up to 1.5 Gy demonstrating 3- to 5-fold enhancement over equivalent X-ray doses. This facility is currently in routine use, irradiating both mice and human blood samples for evaluation of neutron-specific biodosimetry assays. Future studies will focus on dose reconstruction in realistic mixed neutron/photon fields.
Collapse
Affiliation(s)
- Yanping Xu
- a Radiological Research Accelerator Facility, Columbia University, Irvington, New York 10533 and
| | - Gerhard Randers-Pehrson
- a Radiological Research Accelerator Facility, Columbia University, Irvington, New York 10533 and
| | - Helen C Turner
- b Center for Radiological Research, Columbia University, New York, New York 10032
| | - Stephen A Marino
- a Radiological Research Accelerator Facility, Columbia University, Irvington, New York 10533 and
| | - Charles R Geard
- a Radiological Research Accelerator Facility, Columbia University, Irvington, New York 10533 and
| | - David J Brenner
- b Center for Radiological Research, Columbia University, New York, New York 10032
| | - Guy Garty
- a Radiological Research Accelerator Facility, Columbia University, Irvington, New York 10533 and
| |
Collapse
|
4
|
Xu Y, Randers-Pehrson G, Marino SA, Garty G, Harken A, Brenner DJ. Broad Energy Range Neutron Spectroscopy using a Liquid Scintillator and a Proportional Counter: Application to a Neutron Spectrum Similar to that from an Improvised Nuclear Device. Nucl Instrum Methods Phys Res A 2015; 794:234-239. [PMID: 26273118 PMCID: PMC4528388 DOI: 10.1016/j.nima.2015.05.041] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
A novel neutron irradiation facility at the Radiological Research Accelerator Facility (RARAF) has been developed to mimic the neutron radiation from an Improvised Nuclear Device (IND) at relevant distances (e.g. 1.5 km) from the epicenter. The neutron spectrum of this IND-like neutron irradiator was designed according to estimations of the Hiroshima neutron spectrum at 1.5 km. It is significantly different from a standard reactor fission spectrum, because the spectrum changes as the neutrons are transported through air, and it is dominated by neutron energies from 100 keV up to 9 MeV. To verify such wide energy range neutron spectrum, detailed here is the development of a combined spectroscopy system. Both a liquid scintillator detector and a gas proportional counter were used for the recoil spectra measurements, with the individual response functions estimated from a series of Monte Carlo simulations. These normalized individual response functions were formed into a single response matrix for the unfolding process. Several accelerator-based quasi-monoenergetic neutron source spectra were measured and unfolded to test this spectroscopy system. These reference neutrons were produced from two reactions: T(p,n)3He and D(d,n)3He, generating neutron energies in the range between 0.2 and 8 MeV. The unfolded quasi-monoenergetic neutron spectra indicated that the detection system can provide good neutron spectroscopy results in this energy range. A broad-energy neutron spectrum from the 9Be(d,n) reaction using a 5 MeV deuteron beam, measured at 60 degrees to the incident beam was measured and unfolded with the evaluated response matrix. The unfolded broad neutron spectrum is comparable with published time-of-flight results. Finally, the pair of detectors were used to measure the neutron spectrum generated at the RARAF IND-like neutron facility and a comparison is made to the neutron spectrum of Hiroshima.
Collapse
Affiliation(s)
- Yanping Xu
- Radiological Research Accelerator Facility, Columbia University, Irvington, NY 10533
| | | | - Stephen A Marino
- Radiological Research Accelerator Facility, Columbia University, Irvington, NY 10533
| | - Guy Garty
- Radiological Research Accelerator Facility, Columbia University, Irvington, NY 10533
| | - Andrew Harken
- Radiological Research Accelerator Facility, Columbia University, Irvington, NY 10533
| | - David J Brenner
- Radiological Research Accelerator Facility, Columbia University, Irvington, NY 10533
| |
Collapse
|
5
|
Shuryak I, Bryan RA, Broitman J, Marino SA, Morgenstern A, Apostolidis C, Dadachova E. Effects of radiation type and delivery mode on a radioresistant eukaryote Cryptococcus neoformans. Nucl Med Biol 2015; 42:515-23. [PMID: 25800676 DOI: 10.1016/j.nucmedbio.2015.02.006] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2015] [Revised: 02/24/2015] [Accepted: 02/26/2015] [Indexed: 01/22/2023]
Abstract
INTRODUCTION Most research on radioresistant fungi, particularly on human pathogens such as Cryptococcus neoformans, involves sparsely-ionizing radiation. Consequently, fungal responses to densely-ionizing radiation, which can be harnessed to treat life-threatening fungal infections, remain incompletely understood. METHODS We addressed this issue by quantifying and comparing the effects of densely-ionizing α-particles (delivered either by external beam or by (213)Bi-labeled monoclonal antibodies), and sparsely-ionizing (137)Cs γ-rays, on Cryptococcus neoformans. RESULTS The best-fit linear-quadratic parameters for clonogenic survival were the following: α = 0.24 × 10(-2) Gy(-1) for γ-rays and 1.07 × 10(-2) Gy(-1) for external-beam α-particles, and β = 1.44 × 10(-5) Gy(-2) for both radiation types. Fungal cell killing by radiolabeled antibodies was consistent with predictions based on the α-particle dose to the cell nucleus and the linear-quadratic parameters for external-beam α-particles. The estimated RBE (for α-particles vs. γ-rays) at low doses was 4.47 for the initial portion of the α-particle track, and 7.66 for the Bragg peak. Non-radiological antibody effects accounted for up to 23% of cell death. CONCLUSIONS These results quantify the degree of C. neoformans resistance to densely-ionizing radiations, and show how this resistance can be overcome with fungus-specific radiolabeled antibodies.
Collapse
Affiliation(s)
- Igor Shuryak
- Center for Radiological Research, Columbia University Medical Center, New York, New York
| | - Ruth A Bryan
- Department of Radiology, Albert Einstein College of Medicine, Bronx, New York
| | - Jack Broitman
- Department of Radiology, Albert Einstein College of Medicine, Bronx, New York
| | - Stephen A Marino
- Radiological Research Accelerator Facility, Nevis Laboratories, Irvington, New York
| | - Alfred Morgenstern
- European Commission, Joint Research Centre, Institute for Transuranium Elements, Karlsruhe, Germany
| | - Christos Apostolidis
- European Commission, Joint Research Centre, Institute for Transuranium Elements, Karlsruhe, Germany
| | - Ekaterina Dadachova
- Department of Radiology, Albert Einstein College of Medicine, Bronx, New York; Department of Microbiology and Immunology, Albert Einstein College of Medicine, Bronx, New York.
| |
Collapse
|
6
|
Brenner DJ, Vazquez M, Buonanno M, Amundson SA, Bigelow AW, Garty G, Harken AD, Hei TK, Marino SA, Ponnaiya B, Randers-Pehrson G, Xu Y. Integrated interdisciplinary training in the radiological sciences. Br J Radiol 2013; 87:20130779. [PMID: 24363386 DOI: 10.1259/bjr.20130779] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
The radiation sciences are increasingly interdisciplinary, both from the research and the clinical perspectives. Beyond clinical and research issues, there are very real issues of communication between scientists from different disciplines. It follows that there is an increasing need for interdisciplinary training courses in the radiological sciences. Training courses are common in biomedical academic and clinical environments, but are typically targeted to scientists in specific technical fields. In the era of multidisciplinary biomedical science, there is a need for highly integrated multidisciplinary training courses that are designed for, and are useful to, scientists who are from a mix of very different academic fields and backgrounds. We briefly describe our experiences running such an integrated training course for researchers in the field of biomedical radiation microbeams, and draw some conclusions about how such interdisciplinary training courses can best function. These conclusions should be applicable to many other areas of the radiological sciences. In summary, we found that it is highly beneficial to keep the scientists from the different disciplines together. In practice, this means not segregating the training course into sections specifically for biologists and sections specifically for physicists and engineers, but rather keeping the students together to attend the same lectures and hands-on studies throughout the course. This structure added value to the learning experience not only in terms of the cross fertilization of information and ideas between scientists from the different disciplines, but also in terms of reinforcing some basic concepts for scientists in their own discipline.
Collapse
Affiliation(s)
- D J Brenner
- Center for Radiological Research, Columbia University Medical Center, New York, NY, USA
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
7
|
Xu Y, Garty G, Marino SA, Massey TN, Randers-Pehrson G, Johnson GW, Brenner DJ. Novel neutron sources at the Radiological Research Accelerator Facility. J Instrum 2012; 7:C03031. [PMID: 22545061 PMCID: PMC3337765 DOI: 10.1088/1748-0221/7/03/c03031] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Since the 1960s, the Radiological Research Accelerator Facility (RARAF) has been providing researchers in biology, chemistry and physics with advanced irradiation techniques, using charged particles, photons and neutrons.We are currently developing a unique facility at RARAF, to simulate neutron spectra from an improvised nuclear device (IND), based on calculations of the neutron spectrum at 1.5 km from the epicenter of the Hiroshima atom bomb. This is significantly different from a standard fission spectrum, because the spectrum changes as the neutrons are transported through air, and is dominated by neutron energies between 0.05 and 8 MeV. This facility will be based on a mixed proton/deuteron beam impinging on a thick beryllium target.A second, novel facility under development is our new neutron microbeam. The neutron microbeam will, for the first time, provide a kinematically collimated neutron beam, 10-20 micron in diameter. This facility is based on a Proton Microbeam, impinging on a thin lithium target near the threshold of the (7)Li(p,n)(7)Be reaction. This novel neutron microbeam will enable studies of neutron damage to small targets, such as single cells, individual organs within small animals or microelectronic components.
Collapse
Affiliation(s)
- Yanping Xu
- Radiological Research Accelerator Facility, Columbia University, 136 S. Broadway, P.O. Box 21, Irvington, NY 10533, USA
| | - Guy Garty
- Radiological Research Accelerator Facility, Columbia University, 136 S. Broadway, P.O. Box 21, Irvington, NY 10533, USA
| | - Stephen A. Marino
- Radiological Research Accelerator Facility, Columbia University, 136 S. Broadway, P.O. Box 21, Irvington, NY 10533, USA
| | - Thomas N. Massey
- Institute for Nuclear and Particle Physics, Edwards Accelerator Laboratory, Ohio University, Athens, OH 45701
| | - Gerhard Randers-Pehrson
- Radiological Research Accelerator Facility, Columbia University, 136 S. Broadway, P.O. Box 21, Irvington, NY 10533, USA
| | - Gary W. Johnson
- Radiological Research Accelerator Facility, Columbia University, 136 S. Broadway, P.O. Box 21, Irvington, NY 10533, USA
| | - David J. Brenner
- Radiological Research Accelerator Facility, Columbia University, 136 S. Broadway, P.O. Box 21, Irvington, NY 10533, USA
| |
Collapse
|
8
|
Xu Y, Randers-Pehrson G, Marino SA, Bigelow AW, Akselrod MS, Sykora JG, Brenner DJ. An accelerator-based neutron microbeam system for studies of radiation effects. Radiat Prot Dosimetry 2011; 145:373-6. [PMID: 21131327 PMCID: PMC3145382 DOI: 10.1093/rpd/ncq424] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/26/2010] [Revised: 10/15/2010] [Accepted: 10/27/2010] [Indexed: 05/30/2023]
Abstract
A novel neutron microbeam is being developed at the Radiological Research Accelerator Facility (RARAF) of Columbia University. The RARAF microbeam facility has been used for studies of radiation bystander effects in mammalian cells for many years. Now a prototype neutron microbeam is being developed that can be used for bystander effect studies. The neutron microbeam design here is based on the existing charged particle microbeam technology at the RARAF. The principle of the neutron microbeam is to use the proton beam with a micrometre-sized diameter impinging on a very thin lithium fluoride target system. From the kinematics of the ⁷Li(p,n)⁷Be reaction near the threshold of 1.881 MeV, the neutron beam is confined within a narrow, forward solid angle. Calculations show that the neutron spot using a target with a 17-µm thick gold backing foil will be <20 µm in diameter for cells attached to a 3.8-µm thick propylene-bottomed cell dish in contact with the target backing. The neutron flux will roughly be 2000 per second based on the current beam setup at the RARAF singleton accelerator. The dose rate will be about 200 mGy min⁻¹. The principle of this neutron microbeam system has been preliminarily tested at the RARAF using a collimated proton beam. The imaging of the neutron beam was performed using novel fluorescent nuclear track detector technology based on Mg-doped luminescent aluminum oxide single crystals and confocal laser scanning fluorescent microscopy.
Collapse
Affiliation(s)
- Yanping Xu
- Radiological Research Accelerator Facility, Columbia University, Irvington, NY 10533, USA.
| | | | | | | | | | | | | |
Collapse
|
9
|
Marino SA, Johnson GW, Schiff PB, Brenner DJ. Modification of shirt buttons for retrospective radiation dosimetry after a radiological event. Health Phys 2011; 100:542-547. [PMID: 21451325 PMCID: PMC3079536 DOI: 10.1097/hp.0b013e31820153d4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Preliminary results are presented for a personal radiation dosimeter in the form of a clothing button to provide gamma-ray dose estimation for clinically-significant external radiation exposures to the general public due to a radiological incident, such as use of a radiological dispersal device. Rods of thermoluminescent material (LiF:Mg,Ti and LiF:Mg,Cu,P) were encapsulated in plastic "buttons," attached to shirts, and subjected to three cycles of home or commercial laundering or dry cleaning, including ironing or pressing. The buttons were subsequently exposed to doses of 137Cs gamma rays ranging from 0.75 to 8.2 Gy. The rods were removed from the buttons and their light output compared to their responses when bare or to the responses of a set of calibration rods of the same type and from the same manufacturer. In all three of the comparisons for LiF:Mg,Ti rods, the relative responses of the rods in buttons changed by 2-6% relative to the same rods before cleaning. In both comparisons for LiF:Mg,Cu,P rods, the response of laundered rods was 1-3% lower than for the same rods before cleaning. Both these materials are potential candidates for button dosimeters.
Collapse
Affiliation(s)
- Stephen A Marino
- Center for Radiological Research, Columbia University, New York, NY, USA.
| | | | | | | |
Collapse
|
10
|
Kovalchuk O, Zemp FJ, Filkowski JN, Altamirano AM, Dickey JS, Jenkins-Baker G, Marino SA, Brenner DJ, Bonner WM, Sedelnikova OA. microRNAome changes in bystander three-dimensional human tissue models suggest priming of apoptotic pathways. Carcinogenesis 2010; 31:1882-8. [PMID: 20643754 DOI: 10.1093/carcin/bgq119] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
The radiation-induced bystander effect (RIBE) is a phenomenon whereby unexposed cells exhibit molecular symptoms of stress exposure when adjacent or nearby cells are traversed by ionizing radiation (IR). Recent data suggest that RIBE may be epigenetically mediated by microRNAs (miRNAs), which are small regulatory molecules that target messenger RNA transcripts for translational inhibition. Here, we analyzed microRNAome changes in bystander tissues after α-particle microbeam irradiation of three-dimensional artificial human tissues using miRNA microarrays. Our results indicate that IR leads to a deregulation of miRNA expression in bystander tissues. We report that major bystander end points, including apoptosis, cell cycle deregulation and DNA hypomethylation, may be mediated by altered expression of miRNAs. Specifically, c-MYC-mediated upregulation of the miR-17 family was associated with decreased levels of E2F1 and RB1, suggesting a switch to a proliferative state in bystander tissues, while priming these cells for impending death signals. Upregulation of the miR-29 family resulted in decreased levels of its targets DNMT3a and MCL1, consequently affecting DNA methylation and apoptosis. Altered expression of miR-16 led to changes in expression of BCL2, suggesting modulation of apoptosis. Thus, our data clearly show that miRNAs play a profound role in the manifestation of late RIBE end points. In summary, this study creates a roadmap for understanding the role of microRNAome in RIBE and for developing novel RIBE biomarkers.
Collapse
Affiliation(s)
- Olga Kovalchuk
- Department of Biological Sciences, University of Lethbridge, 4401 University Drive, Lethbridge, Alberta, T1K 3M4 Canada.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Randers-Pehrson G, Johnson GW, Marino SA, Xu Y, Dymnikov AD, Brenner DJ. The Columbia University Sub-micron Charged Particle Beam. Nucl Instrum Methods Phys Res A 2009; 609:294-299. [PMID: 20161365 PMCID: PMC2778032 DOI: 10.1016/j.nima.2009.08.041] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
A lens system consisting of two electrostatic quadrupole triplets has been designed and constructed at the Radiological Research Accelerator Facility (RARAF) of Columbia University. The lens system has been used to focus 6-MeV (4)He ions to a beam spot in air with a diameter of 0.8 µm. The quadrupole electrodes can withstand voltages high enough to focus (4)He ions up to 10 MeV and protons up to 5 MeV. The quadrupole triplet design is novel in that alignment is made through precise construction and the relative strengths of the quadrupoles are accomplished by the lengths of the elements, so that the magnitudes of the voltages required for focusing are nearly identical. The insulating sections between electrodes have had ion implantation to improve the voltage stability of the lens. The lens design employs Russian symmetry for the quadrupole elements.
Collapse
|
12
|
Abstract
PURPOSE To address the relationship between the bystander effect and the adaptive response that can compete to impact on the dose-response curve at low doses. MATERIALS AND METHODS A novel radiation apparatus, where targeted and non-targeted cells were grown in close proximity, was used to investigate these phenomena in C3H 10T(1/2) cells. It was further examined whether a bystander effect or an adaptive response could be induced by a factor(s) present in the supernatants of cells exposed to a high or low dose of X-rays, respectively. RESULTS When non-hit cells were co-cultured for 24 h with cells irradiated with 5 Gy alpha-particles, a significant increase in both cell killing and oncogenic transformation frequency was observed. If these cells were treated with 2 cGy X-rays 5 h before co-culture with irradiated cells, approximately 95% of the bystander effect was cancelled out. A 2.5-fold decrease in the oncogenic transformation frequency was also observed. When cells were cultured in medium donated from cells exposed to 5 Gy X-rays, a significant bystander effect was observed for clonogenic survival. When cells were cultured for 5 h with supernatant from donor cells exposed to 2 cGy and were then irradiated with 4 Gy X-rays, they failed to show an increase in survival compared with cells directly irradiated with 4 Gy. However, a twofold reduction in the oncogenic transformation frequency was seen. CONCLUSIONS An adaptive dose of X-rays cancelled out the majority of the bystander effect produced by alpha-particles. For oncogenic transformation, but not cell survival, radioadaption can occur in unirradiated cells via a transmissible factor(s).
Collapse
Affiliation(s)
- S A Mitchell
- Center for Radiological Research, Columbia University, New York, NY 10032, USA
| | | | | | | |
Collapse
|
13
|
Sedelnikova OA, Nakamura A, Kovalchuk O, Koturbash I, Mitchell SA, Marino SA, Brenner DJ, Bonner WM. DNA double-strand breaks form in bystander cells after microbeam irradiation of three-dimensional human tissue models. Cancer Res 2007; 67:4295-302. [PMID: 17483342 DOI: 10.1158/0008-5472.can-06-4442] [Citation(s) in RCA: 159] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The "radiation-induced bystander effect," in which irradiated cells can induce genomic instability in unirradiated neighboring cells, has important implications for cancer radiotherapy and diagnostic radiology as well as for human health in general. Although the mechanisms of this effect remain to be elucidated, we reported previously that DNA double-strand breaks (DSBs), directly measured by gamma-H2AX focus formation assay, are induced in bystander cultured cells. To overcome the deficiencies of cultured cell studies, we examined alpha-particle microbeam irradiation-induced bystander effects in human tissue models, which preserve the three-dimensional geometric arrangement and communication of cells present in tissues in vivo. In marked contrast to DNA DSB dynamics in irradiated cells, in which maximal DSB formation is seen 30 min after irradiation, the incidence of DSBs in bystander cells reached a maximum by 12 to 48 h after irradiation, gradually decreasing over the 7-day time course. At the maxima, 40% to 60% of bystander cells were affected, a 4- to 6-fold increase over controls. These increases in bystander DSB formation were followed by increased levels of apoptosis and micronucleus formation, by loss of nuclear DNA methylation, and by an increased fraction of senescent cells. These findings show the involvement of DNA DSBs in tissue bystander responses and support the notion that bystander DNA DSBs are precursors to widespread downstream effects in human tissues. Bystander cells exhibiting postirradiation signs of genomic instability may be more prone than unaffected cells to become cancerous. Thus, this study points to the importance of considering the indirect biological effects of radiation in cancer risk assessment.
Collapse
Affiliation(s)
- Olga A Sedelnikova
- Laboratory of Molecular Pharmacology, Center for Cancer Research, National Cancer Institute, NIH, Bethesda, Maryland 20892, USA.
| | | | | | | | | | | | | | | |
Collapse
|
14
|
Sykora GJ, Akselrod MS, Salasky M, Marino SA. Novel Al2O3:C,Mg fluorescent nuclear track detectors for passive neutron dosimetry. Radiat Prot Dosimetry 2007; 126:278-83. [PMID: 17522030 DOI: 10.1093/rpd/ncm058] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
The latest advances in the development of a fluorescent nuclear track detector (FNTD) for neutron and heavy charged particle dosimetry are described and compared with CR-39 plastic nuclear etched track detectors (PNTDs). The technique combines a new luminescent aluminium oxide single crystal detector (Al(2)O(3):C,Mg) with an imaging technique based on laser scanning and confocal fluorescence detection. Detection efficiency was obtained after irradiations with monoenergetic neutron and proton beams. Dose dependences were measured for different configurations of the detectors exposed in fast- and thermal-neutron fields. A specially developed image processing technique allows for fast fluorescent track identification and counting. The readout method is non-destructive, and detectors can be reused after thermal annealing.
Collapse
Affiliation(s)
- G Jeff Sykora
- Landauer, Inc., Stillwater Crystal Growth Division, Stillwater, OK 74074, USA
| | | | | | | |
Collapse
|
15
|
Zhu A, Zhou H, Leloup C, Marino SA, Geard CR, Hei TK, Lieberman HB. Differential impact of mouse Rad9 deletion on ionizing radiation-induced bystander effects. Radiat Res 2005; 164:655-61. [PMID: 16238443 PMCID: PMC4052439 DOI: 10.1667/rr3458.1] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
The cellular response to ionizing radiation is not limited to cells irradiated directly but can be demonstrated in neighboring "bystander" populations. The ability of mouse embryonic stem (ES) cells to express a bystander effect and the role of the radioresistance gene Rad9 were tested. Mouse ES cells differing in Rad9 status were exposed to broad-beam 125 keV/ microm 3He alpha particles. All populations, when confluent, demonstrated a dose-independent bystander effect with respect to cell killing, and the Rad9-/- genotype did not selectively alter that response or cell killing after direct exposure to this high-LET radiation. In contrast, relative to Rad9+/+ cells, the homozygous mutant was sensitive to direct exposure to alpha particles when in log phase, providing evidence of a role for Rad9 in repair of potentially lethal damage. Direct exposure to alpha particles induced an increase in the frequency of apoptosis and micronucleus formation, regardless of Rad9 status, although the null mutant showed high spontaneous levels of both end points. All populations demonstrated alpha-particle-induced bystander apoptosis, but that effect was most prominent in Rad9-/- cells. Minimal alpha-particle induction of micronuclei in bystander cells was observed, except for the Rad9-/- mutant, where a significant increase above background was detected. Therefore, the Rad9 null mutation selectively sensitizes mouse ES cells to spontaneous and high-LET radiation-induced bystander apoptosis and micronucleus formation, but it has much less impact on cell killing by direct or bystander alpha-particle exposure. Results are presented in the context of defining the function of Rad9 in the cellular response to radiation and its differential effects on individual bystander end points.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Howard B. Lieberman
- Address for correspondence: Center for Radiological Research, Columbia University College of Physicians and Surgeons, 630 W. 168th St., New York, NY 10032;
| |
Collapse
|
16
|
Belyakov OV, Mitchell SA, Parikh D, Randers-Pehrson G, Marino SA, Amundson SA, Geard CR, Brenner DJ. Biological effects in unirradiated human tissue induced by radiation damage up to 1 mm away. Proc Natl Acad Sci U S A 2005; 102:14203-8. [PMID: 16162670 PMCID: PMC1202386 DOI: 10.1073/pnas.0505020102] [Citation(s) in RCA: 209] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
A central tenet in understanding the biological effects of ionizing radiation has been that the initially affected cells were directly damaged by the radiation. By contrast, evidence has emerged concerning "bystander" responses involving damage to nearby cells that were not themselves directly traversed by the radiation. These long-range effects are of interest both mechanistically and for assessing risks from low-dose exposures, where only a small proportion of cells are directly hit. Bystander effects have been observed largely by using single-cell in vitro systems that do not have realistic multicellular morphology; no studies have as yet been reported in three-dimensional, normal human tissue. Given that the bystander phenomenon must involve cell-to-cell interactions, the relevance of such single-cell in vitro studies is questionable, and thus the significance of bystander responses for human health has remained unclear. Here, we describe bystander responses in a three-dimensional, normal human-tissue system. Endpoints were induction of micronucleated and apoptotic cells. A charged-particle microbeam was used, allowing irradiation of cells in defined locations in the tissue yet guaranteeing that no cells located more than a few micrometers away receive any radiation exposure. Unirradiated cells up to 1 mm distant from irradiated cells showed a significant enhancement in effect over background, with an average increase in effect of 1.7-fold for micronuclei and 2.8-fold for apoptosis. The surprisingly long range of bystander signals in human tissue suggests that bystander responses may be important in extrapolating radiation risk estimates from epidemiologically accessible doses down to very low doses where nonhit bystander cells will predominate.
Collapse
Affiliation(s)
- Oleg V Belyakov
- Center for Radiological Research, Columbia University, New York, NY 10032, USA.
| | | | | | | | | | | | | | | |
Collapse
|
17
|
Brenner DJ, Sawant SG, Hande MP, Miller RC, Elliston CD, Fu Z, Randers-Pehrson G, Marino SA. Routine screening mammography: how important is the radiation-risk side of the benefit-risk equation? Int J Radiat Biol 2002; 78:1065-7. [PMID: 12556334 DOI: 10.1080/0955300021000016576] [Citation(s) in RCA: 40] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
The potential radiation hazards associated with routine screening mammography, in terms of breast cancer induction, are discussed in the context of the potential benefits. The very low energy X-rays used in screening mammography (26-30 kVp) are expected to be more hazardous, per unit dose, than high-energy X- or gamma-rays, such as those to which A-bomb survivors (from which radiation risk estimates are derived) were exposed. Based on in vitro studies using oncogenic transformation and chromosome aberration end-points, as well as theoretical estimates, it seems likely that low doses of low-energy X-rays produce an increased risk per unit dose (compared with high energy photons) of about a factor of 2. Because of the low doses involved in screening mammography, the benefit-risk ratio for older women would still be expected to be large, though for younger women the increase in the estimated radiation risk suggests a somewhat later age than currently recommended--by about 5-10 years--at which to commence routine breast screening.
Collapse
Affiliation(s)
- D J Brenner
- Center for Radiological Research, Columbia University, 630 West 168th Street, New York, NY 10032, USA.
| | | | | | | | | | | | | | | |
Collapse
|
18
|
Marino SA, Johnson GW. A microdosimetry chamber for low-energy X rays. Radiat Prot Dosimetry 2002; 99:377-378. [PMID: 12194331 DOI: 10.1093/oxfordjournals.rpd.a006809] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
A wall-less proportional counter designed to measure single event spectra produced by low energy X rays is described. The sensitive volume of the counter and the housing are made entirely of non-metallic materials to minimise distortions in the secondary electron spectrum.
Collapse
Affiliation(s)
- S A Marino
- RARAF, Center for Radiological Research, Columbia University, PO Box 21, Irvington, NY 10533, USA.
| | | |
Collapse
|
19
|
Geard CR, Jenkins-Baker G, Marino SA, Ponnaiya B. Novel approaches with track segment alpha particles and cell co-cultures in studies of bystander effects. Radiat Prot Dosimetry 2002; 99:233-236. [PMID: 12194293 DOI: 10.1093/oxfordjournals.rpd.a006771] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
There is now a significant body of data that indicate that the effects of ionising radiation may extend to more than those cells that directly suffer damage to DNA in the cell nucleus. Cells neighbouring those cells that are irradiated, or even well separated from those that are irradiated demonstrate several responses that are recorded in hit cells as a function of absorbed dose. That is, the responding non-hit cells are bystanders of hit cells. A protocol has been devised which allows for examination of one means of eliciting bystander responses, specifically, effects on non-contacting cells. Cell culture chambers are set up such that a population of cells is physically separate from the energy depositions of track segment charged particles. Absorption of energy in sub-millimetre distances in the cell culture medium ensures that one population of cells can only respond to factors generated in the irradiated medium or in another population of irradiated co-cultured cells, which may be of similar or dissimilar origin. For irradiation of medium alone, enhanced levels of micronuclei, and of delays in cell cycle progression occur in normal human fibroblasts, but not epithelial cells. This procedure allows for a defining of the factors responsible for initiating bystander effects and for determining their quantitative relevance.
Collapse
Affiliation(s)
- C R Geard
- Radiological Research Accelerator Facility, Center for Radiological Research, College of Physicians and Surgeons of Columbia University, 136 South Broadway, PO Box 21, Irvington, NY 10533, USA.
| | | | | | | |
Collapse
|
20
|
Abstract
PURPOSE Occupational exposure to neutrons typically includes significant doses of low-energy neutrons, with energies below 100 keV. In addition, the normal-tissue dose from boron neutron capture therapy will largely be from low-energy neutrons. Microdosimetric theory predicts decreasing biological effectiveness for neutrons with energies below about 350 keV compared with that for higher-energy neutrons; based on such considerations, and limited biological data, the current radiation weighting factor (quality factor) for neutrons with energies from 10 keV to 100 keV is less than that for higher-energy neutrons. By contrast, some reports have suggested that the biological effectiveness of low-energy neutrons is similar to that of fast neutrons. The purpose of the current work is to assess the relative biological effectiveness of low-energy neutrons for an endpoint of relevance to carcinogenesis: in vitro oncogenic transformation. METHODS Oncogenic transformation induction frequencies were determined for C3H10T1/2 cells exposed to two low-energy neutron beams, respectively, with dose-averaged energies of 40 and 70 keV, and the results were compared with those for higher-energy neutrons and X-rays. RESULTS These results for oncogenic transformation provide evidence for a significant decrease in biological effectiveness for 40 keV neutrons compared with 350 keV neutrons. The 70 keV neutrons were intermediate in effectiveness between the 70 and 350 keV beams. CONCLUSIONS A decrease in biological effectiveness for low-energy neutrons is in agreement with most (but not all) earlier biological studies, as well as microdosimetric considerations. The results for oncogenic transformation were consistent with the currently recommended decreased values for low-energy neutron radiation weighting factors compared with fast neutrons.
Collapse
Affiliation(s)
- R C Miller
- Center for Radiological Research, Columbia University, New York, NY 10032, USA
| | | | | | | | | | | | | |
Collapse
|
21
|
Miller RC, Marino SA, Martin SG, Komatsu K, Geard CR, Brenner DJ, Hall EJ. Neutron-energy-dependent cell survival and oncogenic transformation. J Radiat Res 1999; 40 Suppl:53-59. [PMID: 10804994 DOI: 10.1269/jrr.40.s53] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Both cell lethality and neoplastic transformation were assessed for C3H10T1/2 cells exposed to neutrons with energies from 0.040 to 13.7 MeV. Monoenergetic neutrons with energies from 0.23 to 13.7 MeV and two neutron energy spectra with average energies of 0.040 and 0.070 MeV were produced with a Van de Graaff accelerator at the Radiological Research Accelerator Facility (RARAF) in the Center for Radiological Research of Columbia University. For determination of relative biological effectiveness (RBE), cells were exposed to 250 kVp X rays. With exposures to 250 kVp X rays, both cell survival and radiation-induced oncogenic transformation were curvilinear. Irradiation of cells with neutrons at all energies resulted in linear responses as a function of dose for both biological endpoints. Results indicate a complex relationship between RBEm and neutron energy. For both survival and transformation, RBEm was greatest for cells exposed to 0.35 MeV neutrons. RBEm was significantly less at energies above or below 0.35 MeV. These results are consistent with microdosimetric expectation. These results are also compatible with current assessments of neutron radiation weighting factors for radiation protection purposes. Based on calculations of dose-averaged LET, 0.35 MeV neutrons have the greatest LET and therefore would be expected to be more biologically effective than neutrons of greater or lesser energies.
Collapse
Affiliation(s)
- R C Miller
- Center for Radiological Research, College of Physicians and Surgeons of Columbia University, New York, NY 10032, USA.
| | | | | | | | | | | | | |
Collapse
|
22
|
Obelić B, Srdoc D, Djurić PM, Marino SA. The frequency distribution of the number of ion pairs in irradiated tissue. Radiat Res 1998; 149:411-5. [PMID: 9588350] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
The statistical distribution of the number of ion pairs per ionizing event in a small volume simulating a tissue sphere was obtained by applying the Expectation-Maximization (EM) algorithm to experimental spectra measured by exposing a Rossi-type spherical proportional counter to gamma radiation. The normalized experimental spectrum, r(x), which is the distribution of the number of ion pairs per event from both the primary track and the subsequent electron multiplication, can be represented as Sum(n) p(n) x f(n,x), where the f(n,x)'s for n = 1, 2, 3, ..., n are the normalized spectra for exactly 1, 2, 3, ..., n primary ion pairs and are calculated by convoluting the single-electron spectrum. The coefficients pn represent the mixing proportions of the spectra corresponding to 1, 2, 3, ..., n ion pairs in forming the experimental spectrum. The single-electron spectrum used in our calculations is the distribution of the number of ion pairs due to the multiplication process, and it is represented in analytical form by the Gamma distribution f(1,x) = a x x(b) x e(-cx), where x is energy, usually in eV, and a, b and c are constants. The EM algorithm is an iterative procedure for computing the maximum likelihood or maximum a posteriori estimates of the mixing proportions p(n), which we also refer to as the primary distribution of ion pairs in a microscopic spherical tissue-equivalent volume. The experimental and primary spectra are presented for simulated tissue spheres ranging from 0.25 to 8 microm in diameter exposed to 60Co gamma radiation.
Collapse
Affiliation(s)
- B Obelić
- Ruder Bosković Institute, Zagreb, Croatia
| | | | | | | |
Collapse
|
23
|
Miller RC, Martin SG, Hanson WR, Marino SA, Hall EJ. Effect of track structure and radioprotectors on the induction of oncogenic transformation in murine fibroblasts by heavy ions. Adv Space Res 1998; 22:1719-1723. [PMID: 11542416 DOI: 10.1016/s0273-1177(99)00037-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
The oncogenic potential of high-energy 56Fe particles (1 GeV/nucleon) accelerated with the Alternating Gradient Synchrotron at the Brookhaven National Laboratory was examined utilizing the mouse C3H 10T1/2 cell model. The dose-averaged LET for high-energy 56Fe is estimated to be 143 keV/micrometer with the exposure conditions used in this study. For 56Fe ions, the maximum relative biological effectiveness (RBEmax) values for cell survival and oncogenic transformation were 7.71 and 16.5 respectively. Compared to 150 keV/micrometer 4He nuclei, high-energy 56Fe nuclei were significantly less effective in cell killing and oncogenic induction. The prostaglandin E1 analog misoprostol, an effective oncoprotector of C3H 10T1/2 cells exposed to X rays, was evaluated for its potential as a radioprotector of oncogenic transformation with high-energy 56Fe. Exposure of cells to misoprostol did not alter 56Fe cytotoxicity or the rate of 56Fe-induced oncogenic transformation.
Collapse
Affiliation(s)
- R C Miller
- Center for Radiological Research, Columbia University, New York 10032, USA
| | | | | | | | | |
Collapse
|
24
|
Srdoc D, Marino SA. Microdosimetry of monoenergetic neutrons. Radiat Res 1996; 146:466-74. [PMID: 8927719] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Tissue spheres 0.25, 0.5, 1.0, 2.0, 4.0 and 8.0 micron in diameter were simulated using a wall-less spherical counter filled with propane-based tissue-equivalent gas. Microdosimetric spectra corresponding to these site sizes were measured for five neutron energies (0.22, 0.44, 1.5, 6 and 14 MeV) and the related mean values /yF and /yD were calculated for several site sizes and neutron energies. An elaborate calibration technique combining soft X rays, an 55Fe photon source and a collimated 244Cm alpha-particle source was used throughout the measurements. The spectra and their mean values are compared with theoretically calculated values for ICRU standard tissue. The agreement between the calculated and the measured data is good in spite of a systematic discrepancy, which could be attributed, in part, to the difference in elemental composition between the tissue-equivalent gas and plastic used in the counter and the ICRU standard tissue used in the calculations.
Collapse
Affiliation(s)
- D Srdoc
- Brookhaven National Laboratory, Upton, New York 11973, USA
| | | |
Collapse
|
25
|
|
26
|
Worgul BV, Medvedovsky C, Huang Y, Marino SA, Randers-Pehrson G, Brenner DJ. Quantitative assessment of the cataractogenic potential of very low doses of neutrons. Radiat Res 1996; 145:343-9. [PMID: 8927703] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
We report on the prevalence and relative biological effectiveness (RBE) for various stages of lens opacification in rats induced by very low doses (2 to 250 mGy) of medium-energy (440 keV) neutrons, compared to those for X rays. Neutron doses were delivered either in a single fraction or in four separate fractions and the irradiated animals were followed for over 100 weeks. At the highest observed dose (250 mGy) and at early observation times, there was evidence of an inverse dose-rate effect; i.e., a fractionated exposure was more potent than a single exposure. Neutron RBEs relative to X rays were estimated using a non-parametric technique. The results were only weakly dependent on time postirradiation. At 30 weeks, for example, 80% confidence intervals for the RBE of acutely delivered neutrons relative to X rays were 8-16 at 250 mGy, 10-20 at 50 mGy, 50-100 at 10 mGy and 250-500 at 2 mGy. The results are consistent with the estimated neutron RBEs in Japanese A-bomb survivors, though broad confidence bounds are present in the Japanese results. Our findings are also consistent with data reported earlier for cataractogenesis induced by heavy ions in rats, mice, and rabbits. We conclude from these results that, at very low doses (<10 mGy), the RBE for neutron-induced cataractogenesis is considerably larger than the RBE of 20 commonly used, and use of a significantly larger value for calculating equivalent dose would be prudent.
Collapse
Affiliation(s)
- B V Worgul
- Eye Radiation and Environmental Research Laboratory, Columbia University, New York 10032, USA
| | | | | | | | | | | |
Collapse
|
27
|
Grosso A, Gardelli G, Mei F, Battista G, Boriani F, Ghigi G, Motta R, Marino SA, Burlizzi S, Corinaldesi A. [The correlation between morphology, electrolytic content and risk factors in breast cysts]. Radiol Med 1996; 91:194-7. [PMID: 8628929] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Many studies on the biochemical composition of the liquid aspirated from breast cysts have identified three types of cysts: type I (apocrine) cysts, with a high concentration of K+ and low levels of Na+ and C1-; type II (transudate) cysts, with an electrolytic content similar to that of plasma and high Na+ levels and, finally, type III cysts, with intermediate characteristics. The literature data appear to indicate that the women with type I cysts are at higher risk for breast cancer. The authors report the results of a study carried out on 143 women from October, 1991, through October, 1994, in the Radiology Department of the University of Bologna, to investigate the correlations between some risk factors for breast cancer, the characteristics of cyst fluid and the morphology of the cysts after pneumocystography. Of 186 cysts, 104 (55.9%) were type I, 49 (26.4%) were type II, and 33 (17.7%) were type III. Among the risk factors we considered, only the premenopausal state (41 to 45 years of age) exhibited a statistically significant correlation with the presence of type I cysts. The morphological study of the cysts after pneumocystography showed a surprisingly high correlation between the honeycomb pattern and type I cysts. The constant correlation between cyst morphology and electrolytic content may allow the easy identification of the subgroups of patients eligible for a closer follow-up.
Collapse
Affiliation(s)
- A Grosso
- Istituto di Radiologia, Policlinico S. Orsola, Bologna
| | | | | | | | | | | | | | | | | | | |
Collapse
|
28
|
Worgul BV, Medvedovsky C, Huang Y, Marino SA, Randers-Pehrson G, Brenner DJ. Quantitative Assessment of the Cataractogenic Potential of Very Low Doses of Neutrons. Radiat Res 1996. [DOI: 10.2307/3578991] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
29
|
Miller RC, Geard CR, Martin SG, Marino SA, Hall EJ. Neutron-induced cell cycle-dependent oncogenic transformation of C3H 10T1/2 cells. Radiat Res 1995; 142:270-5. [PMID: 7761576] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Exposure of synchronized populations of mouse C3H 10T1/2 cells to a single dose (0.6 Gy) of 5.9 MeV neutrons at intervals after mitotic shake-off results in a distinctive variation in the oncogenic transformation frequency through the cell cycle. Previous findings show a sensitive window for X-ray-induced oncogenic transformants at late times after mitotic shake-off (14-16 h). Optimal sensitivity to neutrons was observed for cell populations irradiated soon after mitotic shake-off (4-6 h), where the majority of cells would be in the G1 phase of the cell cycle. Additionally, enhanced sensitivity was also found for that period after shake-off (14-16 h) which was maximally sensitive to X rays corresponding to cell populations with a high proportion of G2-phase cells. That is, low-LET radiation (250 kVp X rays) largely appears to produce oncogenic transformants in G2-phase cells, while intermediate-LET radiation (5.9 MeV neutrons) is effective principally on G1- and, to a somewhat lesser extent, G2-phase cells. Cells irradiated with neutrons showed less variation for lethality through the cell cycle than those irradiated with X rays, in agreement with previous findings. The mechanistic basis for the difference in the response of cells in the different phases of the cell cycle to radiations of different quality is unknown but is suggestive of distinct ("signature") molecular changes leading to the observed oncogenic transformation response.
Collapse
Affiliation(s)
- R C Miller
- Center for Radiological Research, College of Physicians and Surgeons, Columbia University, New York, New York 10032, USA
| | | | | | | | | |
Collapse
|
30
|
Miller RC, Marino SA, Brenner DJ, Martin SG, Richards M, Randers-Pehrson G, Hall EJ. The Biological Effectiveness of Radon-Progeny Alpha Particles. II. Oncogenic Transformation as a Function of Linear Energy Transfer. Radiat Res 1995. [DOI: 10.2307/3578966] [Citation(s) in RCA: 51] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
31
|
Miller RC, Marino SA, Brenner DJ, Martin SG, Richards M, Randers-Pehrson G, Hall EJ. The biological effectiveness of radon-progeny alpha particles. II. Oncogenic transformation as a function of linear energy transfer. Radiat Res 1995; 142:54-60. [PMID: 7899559] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Epidemiological studies have established an association between exposure to radon and carcinoma of the lung. However, based on data for either lung cancer in uranium miners exposed to radon or bronchial epithelial carcinomas in Japanese A-bomb survivors, it has not been possible to assign estimates of risk of lung cancer for the general population exposed to radon in their homes. Based on past success with the excellent quantitative properties of the C3H 10T1/2 in vitro oncogenic transformation assay system, the relative biological effectiveness (RBE) for radiation-induced transformation for charged particles of defined LET has been determined. As the LET of the radiation was increased, the rate of induction of oncogenic transformation increased and the RBEm approached 20. At higher LETs, RBE dropped precipitously. The rapid drop in effectiveness for alpha particles with LETs between 120 and 265 keV/microns implies a lower quality factor than the 20-25 currently considered appropriate when estimating lung cancer mortality.
Collapse
Affiliation(s)
- R C Miller
- Center for Radiological Research, College of Physicians and Surgeons of Columbia University, New York, New York 10032
| | | | | | | | | | | | | |
Collapse
|
32
|
Miller RC, Randers-Pehrson G, Hieber L, Marino SA, Richards M, Hall EJ. The Inverse Dose-Rate Effect for Oncogenic Transformation by Charged Particles Is Dependent on Linear Energy Transfer. Radiat Res 1993. [DOI: 10.2307/3578222] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
33
|
Miller RC, Randers-Pehrson G, Hieber L, Marino SA, Richards M, Hall EJ. The inverse dose-rate effect for oncogenic transformation by charged particles is dependent on linear energy transfer. Radiat Res 1993; 133:360-4. [PMID: 8451387] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
Mouse C3H 10T1/2 cells were exposed to single or fractionated doses of charged particles of defined linear energy transfer (LET) from 25 to 200 keV/microns. Dose fractionation with prolonged time intervals enhanced the yield of transformed foci compared with a single acute dose for a range of LET values between 40 and 120 keV/microns. Radiations of lower or higher LET did not show the enhancement that is commonly referred to as the inverse dose-rate effect. The fractionation scheme that was used consisted of three dose fractions; the maximum enhancement of transformation occurred with an interval of 150 min between dose fractions. This inverse dose-rate effect, demonstrated for cycling cells in log phase, was not seen for cells in plateau phase.
Collapse
Affiliation(s)
- R C Miller
- Center for Radiological Research, College of Physicians and Surgeons of Columbia University, New York, New York 10032
| | | | | | | | | | | |
Collapse
|
34
|
Miller RC, Geard CR, Marino SA, Richards M, Randers-Pehrson G. Oncogenic transformation following sequential irradiations with monoenergetic neutrons and X rays. Radiat Res 1991; 125:338-42. [PMID: 2000458] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Mouse C3H 10T1/2 cells were exposed sequentially to low doses (0.1 and 0.3 Gy) of monoenergetic neutrons (0.35, 0.45, 5.9, and 13.7 MeV) and 250-kVp X rays (1 and 3 Gy). The incidences of oncogenic transformation in the cells exposed to neutrons followed by X rays indicated that the effects of the individual radiations were simply additive. This supports the contention that risks associated with the two different radiation modalities may be considered to be additive.
Collapse
Affiliation(s)
- R C Miller
- Center for Radiological Research, College of Physicians & Surgeons, Columbia University, New York, New York 10032
| | | | | | | | | |
Collapse
|
35
|
Miller RC, Brenner DJ, Randers-Pehrson G, Marino SA, Hall EJ. The Effects of the Temporal Distribution of Dose on Oncogenic Transformation by Neutrons and Charged Particles of Intermediate LET. Radiat Res 1990. [DOI: 10.2307/3577679] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
36
|
Miller RC, Brenner DJ, Randers-Pehrson G, Marino SA, Hall EJ. The effects of the temporal distribution of dose on oncogenic transformation by neutrons and charged particles of intermediate LET. Radiat Res 1990; 124:S62-8. [PMID: 2236513] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
The effects of dose rate and dose fractionation on high-LET radiation-induced oncogenic transformation of C3H 10T1/2 cells were examined. Cells were irradiated with graded doses of 5.9-MeV monoenergetic neutrons administered either in single acute exposures (30 mGy/min) or extended over an 8-h period at low dose rates (from 0.21 to 1 mGy/min). Although cell survival studies showed no difference in effect with a change in radiation delivery rate, enhancement of oncogenic transformation occurred when the dose rate was reduced. When the neutron dose was divided into three fractions over 8 h, the biological effect was intermediate between that for the acute and that for the low-dose-rate exposures. Further irradiations were made using deuterons with an LET of 40 keV/microns. The dose-mean lineal energy was comparable to that measured for the 5.9-MeV monoenergetic neutrons. An inverse dose-rate/fractionation effect for the induction of transformation by high-LET deuterons was observed when the time between each of three fractions for a 0.3-Gy total dose was at least 45 min. No further enhancement was seen for longer dose fractionations, suggesting that very long protracted exposures of high-LET radiation would produce no additional enhancement.
Collapse
Affiliation(s)
- R C Miller
- Center for Radiological Research, College of Physicians and Surgeons of Columbia University, New York, New York 10032
| | | | | | | | | |
Collapse
|
37
|
Miller RC, Geard CR, Brenner DJ, Komatsu K, Marino SA, Hall EJ. Neutron-energy-dependent oncogenic transformation of C3H 10T1/2 mouse cells. Radiat Res 1989; 117:114-27. [PMID: 2913605] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
The relative biological effectiveness (RBE) of a range of neutron energies relative to 250-kVp X rays has been determined for oncogenic transformation and cell survival in the mouse C3H 10T 1/2 cell line. Monoenergetic neutrons at 0.23, 0.35, 0.45, 0.70, 0.96, 1.96, 5.90, and 13.7 MeV were generated at the Radiological Research Accelerator Facility of the Radiological Research Laboratories, Columbia University, and were used to irradiate asynchronous cells at low absorbed doses from 0.05 to 1.47 Gy. X irradiations covered the range 0.5 to 8 Gy. Over the more than 2-year period of this study, the 31 experiments provided comprehensive information, indicating minimal variability in control material, assuring the validity of comparisons over time. For both survival and transformation, a curvilinear dose response for X rays was contrasted with linear or nearly linear dose responses for the various neutron energies. RBE increased as dose decreased for both end points. Maximal RBE values for transformation ranged from 13 for cells exposed to 5.9-MeV neutrons to 35 for 0.35-MeV neutrons. This study clearly shows that over the range of neutron energies typically seen by nuclear power plant workers and individuals exposed to the atomic bombs in Japan, a wide range of RBE values needs to be considered when evaluating the neutron component of the effective dose. These results are in concordance with the recent proposals in ICRU 40 both to change upward and to vary the quality factor for neutron irradiations.
Collapse
Affiliation(s)
- R C Miller
- Radiological Research Laboratories, College of Physicians & Surgeons, Columbia University, New York, New York 10032
| | | | | | | | | | | |
Collapse
|
38
|
Miller RC, Brenner DJ, Geard CR, Komatsu K, Marino SA, Hall EJ. Oncogenic transformation by fractionated doses of neutrons. Radiat Res 1988; 114:589-98. [PMID: 3375445] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
Oncogenic transformation was assayed after C3H 10T1/2 cells were irradiated with monoenergetic neutrons; cells were exposed to 0.23-, 0.35-, 0.45-, 5.9-, and 13.7-MeV neutrons given singly or in five equal fractions over 8 h. At the biologically effective neutron energy of 0.45 MeV, enhancement of transformation was evident with some small fractionated doses (below 1 Gy). When transformation was examined as a function of neutron energy at 0.5 Gy, enhancement was seen for cells exposed to three of the five energies (0.35, 0.45, and 5.9 MeV). Enhancement was greatest for cells irradiated with 5.9-MeV neutrons. Of the neutron energies examined, 5.9-MeV neutrons had the lowest dose-averaged lineal energy and linear energy transfer. This suggests that enhancement of transformation by fractionated low doses of neutrons may be radiation-quality dependent.
Collapse
Affiliation(s)
- R C Miller
- Department of Radiation Oncology, College of Physicians & Surgeons, Columbia University, New York, New York 10032
| | | | | | | | | | | |
Collapse
|
39
|
|
40
|
Bird RP, Zaider M, Rossi HH, Hall EJ, Marino SA, Rohrig N. The sequential irradiation of mammalian cells with X rays and charged particles of high LET. Radiat Res 1983; 93:444-52. [PMID: 6856752] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Chinese hamster V79 cells, synchronized in late-S phase, were irradiated with high-LET charged particles or X rays, or exposed sequentially to a single dose of charged particles followed by graded doses of X rays. The charged-particle irradiations consisted of deuterons (LET, 50 keV/microns) or 3He ions (96 or 160 keV/microns). The survival data obtained following the sequential irradiations show a synergistic effect compared with exposure to the low-LET radiation. An enhancement ratio is defined in order to quantify this effect. On the basis of this concept the present data show an enhanced interaction effect as the LET of the primary dose is increased or the size of this dose is increased. The data are also discussed in terms of a recent theoretical formulation which predicts synergism as a result of the interaction between the sublethal damage produced by the two radiations.
Collapse
|
41
|
DeWyngaert JK, Leith JT, Peck RA, Bliven SF, Zeman EM, Marino SA, Glicksman AS. Differential RBE Values Obtained for Mammary Adenocarcinoma Tumor Cell Subpopulations after 14.8-MeV Neutron Irradiation. Radiat Res 1981. [DOI: 10.2307/3575757] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
42
|
DeWyngaert JK, Leith JT, Peck RA, Bliven SF, Zeman EM, Marino SA, Glicksman AS. Differential RBE values obtained for mammary adenocarcinoma tumor cell subpopulations after 14.8-MeV neutron irradiation. Radiat Res 1981; 88:118-31. [PMID: 7302122] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
|
43
|
Bird RP, Rohrig N, Colvett RD, Geard CR, Marino SA. Inactivation of synchronized Chinese Hamster V79 cells with charged-particle track segments. Radiat Res 1980; 82:277-89. [PMID: 6246560] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
|
44
|
Bird RP, Rohrig N, Colvett RD, Geard CR, Marino SA. Inactivation of Synchronized Chinese Hamster V79 Cells with Charged-Particle Track Segments. Radiat Res 1980. [DOI: 10.2307/3575379] [Citation(s) in RCA: 55] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
45
|
Rini FJ, Hall EJ, Marino SA. The oxygen enhancement ratio as a function of neutron energy with mammalian cells in culture. Radiat Res 1979; 78:25-37. [PMID: 451143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
46
|
|
47
|
Hall EJ, Novak JK, Marino SA. Comparative radiobiological measurements with two high-energy cyclotron-produced neutron beams presently used for radiotherapy. Br J Radiol 1974; 47:882-7. [PMID: 4215532 DOI: 10.1259/0007-1285-47-564-882] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023] Open
|
48
|
Bengtsson LG, Goodman LJ, Marino SA, Robertson JS. Computer evaluation of monoenergetic neutron irradiations in radiobiology. Health Phys 1970; 18:577-578. [PMID: 5513089] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
|