1
|
A multi-city study of indoor air quality in green vs non-green low-income housing. ENVIRONMENTAL RESEARCH 2024; 240:117576. [PMID: 37923110 DOI: 10.1016/j.envres.2023.117576] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Revised: 10/31/2023] [Accepted: 11/01/2023] [Indexed: 11/07/2023]
Abstract
OBJECTIVES The condition of the home is a strong predictor of exposure to environmental contaminants, with low-income households being particularly vulnerable. Therefore, improving housing standards is a priority. Housing built to "green" standards, with improved building methods and materials, has been suggested to reduce contaminants. However, evidence is limited as to which contaminants are reduced. The Green Housing Study was conducted to address this issue. The study hypothesis was that housing built using green components has lower concentrations of environmental contaminants compared to conventional housing. METHODS A repeated-measures, 12-month cohort study was performed in three U.S. cities. Data were collected in the home at three time points throughout a year. The level of contaminants were estimated using air samples for particulate matter and black carbon, dust samples for aeroallergens and pesticides, and resident or study staff reporting evidence of mold. To investigate source(s) of PM2.5 and black carbon, multivariable models using stepwise variable selection were developed. RESULTS In adjusted generalized estimating equations (GEE) models, black carbon concentration (μg/m3) (β = -0.22, 95% CI = -0.38 to -0.06, p = 0.01), permethrin (OR = 0.28, 95% CI = 0.15-0.49, p < 0.0001), and reported mold (OR = 0.29, 95% CI = 0.13-0.68, p = 0.003) were significantly lower in green homes. Cockroach antigen was also lower in green homes (OR = 0.59, 95% CI = 0.33-1.08, p = 0.09), although not statistically significant. We found that 68% of PM2.5 was explained by dwelling type and smoking and 42% of black carbon was explained by venting while cooking and use of a gas stove. CONCLUSIONS This study provides quantitative data suggesting benefits of incorporating green building practices on the level of numerous environmental contaminants known to be associated with health. Occupant behavior, particularly smoking, is an important contributor to indoor air pollution.
Collapse
|
2
|
The effects of waste sorting in environmental microbiome, THP-1 cell viability and inflammatory responses. ENVIRONMENTAL RESEARCH 2020; 185:109450. [PMID: 32244107 DOI: 10.1016/j.envres.2020.109450] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/21/2020] [Revised: 02/28/2020] [Accepted: 03/25/2020] [Indexed: 06/11/2023]
Abstract
Workers in the waste sorting industry are exposed to diverse bioaerosols. Characterization of these bioaerosols is necessary to more accurately assess the health risks of exposure. The use of high-throughput DNA sequencing for improved analysis of microbial composition of bioaerosols, in combination with their in vitro study in relevant cell cultures, represents an important opportunity to find answers on the biological effects of bioaerosols. This study aimed to characterize by high-throughput sequencing the biodiversity present in complex aerosol mixtures retained in forklift air conditioning filters of a waste-sorting industry and its effects on cytotoxicity and secretion of proinflammatory cytokines in vitro using human macrophages derived from monocytic THP-1 cells. Seventeen filters from the filtration system from forklifts operating in one waste sorting facility and one control filter (similar filter without prior use) were analyzed using high-throughput sequencing and toxicological tests in vitro. A trend of positive correlation was seen between the number of bacterial and fungal OTUs (r = 0.47, p = 0.06). Seven filters (39%) exhibited low or moderate cytotoxicity (p < 0.05). The highest cytotoxic responses had a reduction in cell viability between 17 and 22%. Filter samples evoked proinflammatory responses, especially the production of TNFα. No significant correlation was found between fungal richness and inflammatory responses in vitro. The data obtained stress the need of thorough exposure assessment in waste-sorting industry and to take immunomodulatory properties into consideration for bioaerosols hazard characterization. The broad spectrum of microbial contamination detected in this study demonstrates that adequate monitoring of bioaerosol exposure is necessary to evaluate and minimize risks. The combined techniques can support the implementation of effective environmental monitoring programs of public and occupational health importance.
Collapse
|
3
|
Retention of fungal enzyme activity in environmental liquid and filter samples. ENVIRONMENTAL SCIENCE. PROCESSES & IMPACTS 2017; 19:134-140. [PMID: 28079907 DOI: 10.1039/c6em00554c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Fungal biomass can be determined by measuring the beta-N-acetylhexos-aminidase (NAHA) enzyme activity. NAHA, an enzyme present in fungal mycelium and spores, has been detected in inactive, dormant and non-viable cells. Very little information is available on the enzyme activity of different species or retention of the activity under various storage conditions. This study used fluorometry to evaluate the enzyme activity of liquid and filter samples containing spores of four fungal species from genera Penicillium, Cladosporium, Aspergillus, and Acremonium. When fungal spores were stored on a filter, enzyme activity was more stable than when the spores were maintained in suspension for one year. The enzyme activity in suspension samples increased with most of the differences detected between the values at the baseline and 12 months being statistically significant. The results indicate that enzyme activity varies between species. Cladosporium spores had highest NAHA content per spore, whereas Acremonium did not exhibit any detectable enzyme activity even when viability was detected. The results indicated that samples should be stored as dry filter samples.
Collapse
|
4
|
An emerging paradox: Toward a better understanding of the potential benefits and adversity of microbe exposures in the indoor environment. INDOOR AIR 2017; 27:3-5. [PMID: 28025873 DOI: 10.1111/ina.12344] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
|
5
|
Effects of fungal species, cultivation time, growth substrate, and air exposure velocity on the fluorescence properties of airborne fungal spores. INDOOR AIR 2015; 25:653-661. [PMID: 25292152 DOI: 10.1111/ina.12166] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/12/2014] [Accepted: 09/30/2014] [Indexed: 06/03/2023]
Abstract
UNLABELLED Real-time bioaerosol monitoring is possible with fluorescence based instruments. This study provides information on major factors that can affect the fluorescence properties of airborne fungal spores. Two fluorescence-based bioaerosol detectors, BioScout, and ultraviolet aerodynamic particle sizer (UVAPS), were used to study fluorescent particle fractions (FPFs) of released spores of three fungal species (Aspergillus versicolor, Cladosporium cladosporioides, and Penicillium brevicompactum). Two culture media (agar and gypsum board), three ages of the culture (one week, one month, and four months), and three aerosolization air velocities (5, 15, and 27 m/s) were tested. The results showed that the FPF values for spores released from gypsum were typically lower than for those released from agar indicating that poor nutrient substrate produces spores with lower amounts of fluorescent compounds. The results also showed higher FPF values with lower air velocities in aerosolization. This indicates that easily released fully developed spores have more fluorescent compounds compared to forcibly extracted non-matured spores. The FPFs typically were lower with older samples. The FPF results between the two instruments were similar, except with four-month-old samples. The results can be utilized in field measurements of fungal spores to estimate actual concentrations and compare different instruments with fluorescence-based devices as well as in instrument calibration and testing in laboratory conditions. PRACTICAL IMPLICATIONS Fluorescence-based instruments are the only choice for real-time detection of fungal spores at the moment. In general, all fluorescence-based bioaerosol instruments are tested against known bacterial and fungal spores in laboratory conditions. This study showed that fungal species, growth substrate, age of culture, and air current exposure rate have an effect on detection efficiency of fungal spores in the fluorescence-based instruments. Therefore, these factors should be considered in the instrument calibration process. The results are also important when interpreting results of fluorescence-based field measurements of fungal spores.
Collapse
|
6
|
Duration of day care attendance during infancy predicts asthma at the age of seven: the Cincinnati Childhood Allergy and Air Pollution Study. Clin Exp Allergy 2015; 44:1274-81. [PMID: 25179746 DOI: 10.1111/cea.12397] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2014] [Revised: 06/11/2014] [Accepted: 07/28/2014] [Indexed: 12/25/2022]
Abstract
BACKGROUND Studies vary with respect to the reported effects of day care attendance on childhood asthma. OBJECTIVES To evaluate the independent and combined effects of day care attendance and respiratory infections on the development of asthma at the age of seven in a prospective birth cohort. METHOD At the age of seven, the study sample included 589 children with complete data of 762 enrolled at birth. Day care hours and number of respiratory infections were reported in follow-up questionnaires through age four. At 7 years of age, asthma was diagnosed in 95 children (16%), based on predefined symptoms criteria confirmed by either asthma FEV1 reversibility after bronchodilator or a positive methacholine test (PC20 ≤ 4 mg/mL). Logistic regression was used to investigate the relationships between asthma at the age of seven, cumulative hours of day care attendance and reported respiratory infections at ages 1-4. RESULTS In the univariate analyses, day care attendance at 12 months was associated with an increased risk of asthma [odds ratio (OR) = 1.8, 95% confidence interval (CI) = 1.1-3.0]. Both upper and lower respiratory infections at 12 months also increased the likelihood of asthma [OR = 2.4 (1.4-4.1); OR = 2.3 (1.5-3.7), respectively]. In the final multivariate logistic model, cumulative hours of day care attendance and number of lower respiratory infections at 12 months were associated with asthma [OR = 1.2 (1.1-1.5); OR = 1.4 (1.2-1.7), respectively]. However, a threshold of greater than 37.5 hours per week of day care attendance was associated with a lower risk of asthma [OR = 0.6 (0.4-0.9)]. CONCLUSION Depending on duration of attendance, day care during infancy can either increase or reduce risk of asthma at the age of seven.
Collapse
|
7
|
Susceptibility of green and conventional building materials to microbial growth. INDOOR AIR 2015; 25:273-84. [PMID: 24975616 DOI: 10.1111/ina.12140] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/21/2014] [Accepted: 06/20/2014] [Indexed: 05/04/2023]
Abstract
Green building materials are becoming more popular. However, little is known about their ability to support or limit microbial growth. The growth of fungi was evaluated on five building materials. Two green, two conventional building materials and wood as a positive control were selected. The materials were inoculated with Aspergillus versicolor, Cladosporium cladosporioides and Penicillium brevicompactum, in the absence and presence of house dust. Microbial growth was assessed at four different time points by cultivation and determining fungal biomass using the N-acetylhexosaminidase (NAHA) enzyme assay. No clear differences were seen between green and conventional building materials in their susceptibility to support microbial growth. The presence of dust, an external source of nutrients, promoted growth of all the fungal species similarly on green and conventional materials. The results also showed a correlation coefficient ranging from 0.81 to 0.88 between NAHA activity and culturable counts. The results suggest that the growth of microbes on a material surface depends on the availability of organic matter rather than the classification of the material as green or conventional. NAHA activity and culturability correlated well indicating that the two methods used in the experiments gave similar trends for the growth of fungi on material surfaces.
Collapse
|
8
|
Concentration gradient patterns of traffic and non-traffic-generated fine and coarse aerosol particles. JOURNAL OF ENVIRONMENTAL HEALTH 2014; 76:122-9. [PMID: 24645423 PMCID: PMC6719303] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
The research project described in this article was undertaken to establish baseline information for a Health Impact Assessment (HIA) project of Interstate 75 road construction in Cincinnati, Ohio. The objective of the authors' study was to evaluate the concentrations of elemental and organic carbon (EC and OC), as well as characterize particle number concentrations using devices that measure the fine fraction in the range of 0.02-1 microm and the coarse fraction up to 20 pm. The measurements were conducted at two sites located in the proximity of an interstate highway (at 124 and 277 m) as well as at a remote control site (at >2000 m from any interstate highway). Samples were collected for 24 hours over 12 days in each season (i.e., summer, fall, and winter). Wind data were obtained from the area weather station. Data were analyzed using mixed linear models. Significant increases in concentrations of EC, OC, and fine particles as well as in EC/OC ratios were observed with decreased distance to the highway; this difference was more pronounced in the fall. These results suggest that residents and workers in areas near high-traffic highways may be exposed to elevated levels of airborne fine particles. The results can be used as a baseline for future HIAs of road construction in the area.
Collapse
|
9
|
Stenotrophomonas, Mycobacterium, and Streptomyces in home dust and air: associations with moldiness and other home/family characteristics. INDOOR AIR 2013; 23:387-96. [PMID: 23397905 PMCID: PMC3679357 DOI: 10.1111/ina.12035] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/31/2012] [Accepted: 02/06/2013] [Indexed: 05/15/2023]
Abstract
Respiratory illnesses have been linked to children's exposures to water-damaged homes. Therefore, understanding the microbiome in water-damaged homes is critical to preventing these illnesses. Few studies have quantified bacterial contamination, especially specific species, in water-damaged homes. We collected air and dust samples in twenty-one low-mold homes and twenty-one high-mold homes. The concentrations of three bacteria/genera, Stenotrophomonas maltophilia, Streptomyces sp., and Mycobacterium sp., were measured in air and dust samples using quantitative PCR (QPCR). The concentrations of the bacteria measured in the air samples were not associated with any specific home characteristic based on multiple regression models. However, higher concentrations of S. maltophilia in the dust samples were associated with water damage, that is, with higher floor surface moisture and higher concentrations of moisture-related mold species. The concentrations of Streptomyces and Mycobacterium sp. had similar patterns and may be partially determined by human and animal occupants and outdoor sources of these bacteria.
Collapse
|
10
|
Airborne fungal cell fragments in homes in relation to total fungal biomass. INDOOR AIR 2013; 23:142-147. [PMID: 22804753 DOI: 10.1111/j.1600-0668.2012.00799.x] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/05/2012] [Accepted: 06/25/2012] [Indexed: 06/01/2023]
Abstract
Fungal exposure may induce respiratory symptoms. The causative agents are compounds in the fungal cell wall. Fragments of microbes may be present in air samples but are not measurable using conventional spore counting or by the determination of viable organisms. This study assesses the proportion of fungal cell biomass and endotoxin in different particle size fractions in air samples from homes. Air samples were collected from 15 homes using a cyclone sampler, collecting particles in three aerodynamic size fractions: <1.0, 1.0-1.8, and >1.8 μm. N-Acetylhexosaminidase (NAHA) was determined as a marker of fungal cell biomass. Endotoxin was determined using the Limulus amebocyte lysate method. NAHA and endotoxin in the size range <1.0 μm comprised up to 63% (mean 22.7%) and 96.3% (mean 22.6%) of the total concentrations, respectively. There were significant relationships between the amounts of NAHA and endotoxin in the total amount and in the size fraction >1.8 μm but not in the smaller fractions. The results demonstrate significant amounts of fungal cell biomass and endotoxin in particles <1.0 μm. Homes with reported mold damage had a lower concentration of NAHA in particles <1.0 μm than homes without mold damage. To assess airborne exposure for diagnostic and preventive purposes, measurement techniques that include this fraction should be considered.
Collapse
|
11
|
|
12
|
Possible application of the environmental relative moldiness index (ermi) in brittany, france. J Mycol Med 2012. [DOI: 10.1016/j.mycmed.2012.07.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
13
|
|
14
|
Comparison of Two Analytical Methods for Detecting (1-3)-β-D-Glucan in Pure Fungal Cultures and in Home Dust Samples. ACTA ACUST UNITED AC 2008. [DOI: 10.2174/1874838400801010026] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
There are two methods available for the analysis of (1-3)-β-D-glucan: the Limulus Amebocyte Lysate assay
(LAL) and the inhibition Enzyme Immunoassay (EIA). The aim of this study was to compare the accuracy and specificity
of these two methods in detecting eight alpha and beta-glucan standards, and their sensitivity for the analysis of (1-3)-β-
D-glucan content of common indoor fungal species and indoor dust samples. The results show that the LAL assay is more
accurate, specific, and sensitive in measuring linear and branched β-D-glucans than the EIA. The greatest LAL-analyzed
(1-3)-β-D-glucan content per spore (241 pg/spore) was found with E. nigrum, which also had the largest spore size (28
μm). The biomass-normalized (1-3)-β-D-glucan content of fungal spores from pure cultures was within similar range with
the two assays but no correlation was found between the results from the two assays. In contrast, there was a significant
correlation between the EIA and LAL-measured (1-3)-β-D-glucan concentrations (μg/m2 of floor area) in field dust samples.
Collapse
|
15
|
Use of (1-3)-beta-d-glucan concentrations in dust as a surrogate method for estimating specific fungal exposures. INDOOR AIR 2008; 18:225-232. [PMID: 18429996 DOI: 10.1111/j.1600-0668.2008.00526.x] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
UNLABELLED Indoor exposure to fungi has been associated with respiratory symptoms,often attributed to their cell wall component, (1-3)-beta-D-glucan. Performing(1-3)-beta-D-glucan analysis is less time consuming and labor intensive than cultivation or microscopic counting of fungal spores. This has prompted many to use(1-3)-beta-D-glucan as a surrogate for fungal exposure. The aim of this study was to examine which indoor fungal species are major contributors to the (1-3)-beta-D-glucan concentration in field dust samples. We used the quantitative polymerase chain reaction (QPCR) method to analyze 36 indoor fungal species in 297 indoor dust samples. These samples were also simultaneously analyzed for (1-3)-beta-D-glucan concentration using the endpoint chromogenic Limulus Amebocyte lysate assay. Linear regression analysis, followed by factor analysis and structural equation modeling, were utilized in order to identify fungal species that mostly contribute to the (1-3)-beta-D-glucan concentration in field dust samples. The study revealed that Cladosporium and Aspergillus genera, as well as Epicoccum nigrum, Penicillium brevicompactum and Wallemia sebi were the most important contributors to the (1-3)-beta-D-glucan content of these home dust samples. The species that contributed most to the (1-3)-beta-D-glucan concentration were also the most prevalent in indoor environments. However, Alternaria alternata, a common fungal species in indoor dust, did not seem to be a significant source of (1-3)-beta-D-glucan. PRACTICAL IMPLICATIONS This study revealed that the (1-3)-beta-D-glucan content of different fungal species varies widely. (1-3)-beta-D-glucan inhouse dust from the Greater Cincinnati area may be a good marker for some fungal species of the Cladosporium and Aspergillus genera. In contrast, Alternaria alternata did not contribute much to the (1-3)-beta-D-glucan load. Therefore, (1-3)-beta-D-glucan concentration in field samples as a surrogate for total fungal exposure should be used with caution.
Collapse
|
16
|
Abstract
BACKGROUND (1-3)-Beta-D-glucan is a fungal cell wall component, suspected to cause respiratory symptoms in adults. However, very little is known on the possible health effects of (1-3)-beta-D-glucan during infancy. We examined the association between (1-3)-beta-D-glucan exposure and the prevalence of allergen sensitization and wheezing during the first year of life in a birth cohort of 574 infants born to atopic parents. Endotoxin exposure was included as a possible confounder. METHODS (1-3)-Beta-D-glucan and endotoxin exposures were measured in settled dust collected from infants' primary activity rooms. The primary outcomes at approximately age one included parental reports of recurrent wheezing and allergen sensitization evaluated by skin prick testing to a panel of 15 aeroallergens as well as milk and egg white. RESULTS Exposure to high (1-3)-beta-D-glucan concentration (within fourth quartile) was associated with reduced likelihood of both recurrent wheezing [adjusted OR (aOR) = 0.39, 95% CI = 0.16-0.93] and recurrent wheezing combined with allergen sensitization (aOR = 0.13, 95% CI = 0.03-0.61). Similar trends were found between (1-3)-beta-D-glucan concentrations and allergen sensitization (aOR = 0.57, 95% CI = 0.30-1.10). In contrast, recurrent wheezing with or without allergen sensitization was positively associated with low (1-3)-beta-D-glucan exposure within the first quartile (aOR = 3.04, 95% CI = 1.25-7.38; aOR = 4.89, 95% CI = 1.02-23.57). There were no significant associations between endotoxin exposure and the studied health outcomes. CONCLUSIONS This is the first study to report that indoor exposure to high levels of (1-3)-beta-D-glucan (concentration >60 microg/g) is associated with decreased risk for recurrent wheezing among infants born to atopic parents. This effect was more pronounced in the subgroup of allergen-sensitized infants.
Collapse
|
17
|
|
18
|
Relationship between indoor and outdoor bio-aerosols collected with a button inhalable aerosol sampler in urban homes. INDOOR AIR 2006; 16:37-47. [PMID: 16420496 PMCID: PMC2233950 DOI: 10.1111/j.1600-0668.2005.00396.x] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
This field study investigated the relationship between indoor and outdoor concentrations of airborne actinomycetes, fungal spores, and pollen. Air samples were collected for 24 h with a button inhalable aerosol sampler inside and outside of six single-family homes located in the Cincinnati area (overall, 15 pairs of samples were taken in each home). The measurements were conducted during three seasons - spring and fall 2004, and winter 2005. The concentration of culturable actinomycetes was mostly below the detection limit. The median indoor/outdoor ratio (I/O) for actinomycetes was the highest: 2.857. The indoor of fungal and pollen concentrations followed the outdoor concentrations while indoor levels were mostly lower than the outdoor ones. The I/O ratio of total fungal spores (median=0.345) in six homes was greater than that of pollen grains (median=0.025). The low I/O ratios obtained for pollen during the peak ambient pollination season (spring) suggest that only a small fraction penetrated from outdoor to indoor environment. This is attributed to the larger size of pollen grains. Higher indoor concentration levels and variability in the I/O ratio observed for airborne fungi may be associated with indoor sources and/or higher outdoor-to-indoor penetration of fungal spores compared to pollen grains. Practical Implication This study addresses the relationship between indoor and outdoor concentrations of three different types of bio-aerosols, namely actinomycetes, fungal spores, and pollen grains. The results show that actinomycetes are rare in indoor and outdoor air in Midwest, USA. Exposure to pollen occurs mainly in the outdoor air even during peak pollen season. Unexpectedly high fungal spore concentrations were measured outdoors during winter. The presented pilot database on the inhalable levels of indoor and outdoor bio-aerosols can help apportion and better characterize the inhalation exposure to these bio-aerosols. Furthermore, the data can be incorporated into existing models to quantify the penetration of biological particles into indoor environments from outdoors.
Collapse
|
19
|
Gene-Environment Interaction between CD14 -159C→T and Diesel Exhaust Particle (DEP) Exposure Underlying Aero Allergen Sensitization. J Allergy Clin Immunol 2006. [DOI: 10.1016/j.jaci.2005.12.734] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
20
|
Abstract
UNLABELLED Numerous techniques have been developed over the years for reducing aerosol exposure in indoor air environments. Among indoor air purifiers of different types, ionic emitters have gained increasing attention and are presently used for removing dust particles, aeroallergens and airborne microorganisms from indoor air. In this study, five ionic air purifiers (two wearable and three stationary) that produce unipolar air ions were evaluated with respect to their ability to reduce aerosol exposure in confined indoor spaces. The concentration decay of respirable particles of different properties was monitored in real time inside the breathing zone of a human manikin, which was placed in a relatively small (2.6 m3) walk-in chamber during the operation of an ionic air purifier in calm air and under mixing air condition. The particle removal efficiency as a function of particle size was determined using the data collected with a size-selective optical particle counter. The removal efficiency of the more powerful of the two wearable ionic purifiers reached about 50% after 15 min and almost 100% after 1.5 h of continuous operation in the chamber under calm air conditions. In the absence of external ventilation, air mixing, especially vigorous one (900 CFM), enhanced the air cleaning effect. Similar results were obtained when the manikin was placed inside a partial enclosure that simulated an aircraft seating configuration. All three stationary ionic air purifiers tested in this study were found capable of reducing the aerosol concentration in a confined indoor space. The most powerful stationary unit demonstrated an extremely high particle removal efficiency that increased sharply to almost 90% within 5-6 min, reaching about 100% within 10-12 min for all particle sizes (0.3-3 microm) tested in the chamber. For the units of the same emission rate, the data suggest that the ion polarity per se (negative vs. positive) does not affect the performance but the ion emission rate does. The effects of particle size (within the tested range) and properties (NaCl, PSL, Pseudomonas fluorescens bacteria) as well as the effects of the manikin's body temperature and its breathing on the ionic purifier performance were either small or insignificant. The data suggest that the unipolar ionic air purifiers are particularly efficient in reducing aerosol exposure in the breathing zone when used inside confined spaces with a relatively high surface-to-volume ratio. PRACTICAL IMPLICATIONS Ionic air purifiers have become increasingly popular for removing dust particles, aeroallergens and airborne microorganisms from indoor air in various settings. While the indoor air cleaning effect, resulting from unipolar and bipolar ion emission, has been tested by several investigators, there are still controversial claims (favorable and unfavorable) about the performance of commercially available ionic air purifiers. Among the five tested ionic air purifiers (two wearable and three stationary) producing unipolar air ions, the units with a higher ion emission rate provided higher particle removal efficiency. The ion polarity (negative vs. positive), the particle size (0.3-3 microm) and properties (NaCl, PSL, Pseudomonas fluorescens bacteria), as well as the body temperature and breathing did not considerable affected the ionization-driven particle removal. The data suggest that the unipolar ionic air purifiers are particularly efficient in reducing aerosol exposure in the breathing zone when they are used inside confined spaces with a relatively high surface-to-volume ratio (such as automobile cabins, aircraft seating areas, bathrooms, cellular offices, small residential rooms, and animal confinements). Based on our experiments, we proposed that purifiers with a very high ion emission rate be operated in an intermittent mode if used indoors for extended time periods. As the particles migrate to and deposit on indoor surfaces during the operation of ionic air purifiers, some excessive surface contamination may occur, which introduces the need of periodic cleaning these surfaces.
Collapse
|
21
|
Abstract
UNLABELLED The airborne fungal concentration measured with air samplers during specific time intervals may not adequately represent the indoor air quality because of the sporadic nature of spore release from sources. The conventional source evaluation (e.g. swab and tape sampling) characterizes the mold source but does not relate to the fraction of spores that can be aerosolized from a contaminated material. As an alternative to these methods, we have recently developed and laboratory-tested a novel Fungal Spore Source Strength Tester (FSSST). It allows assessing the potential of aerosolization of fungal spores from contaminated surfaces under the most favorable release conditions. In this study, the FSSST was used to characterize the release of spores from four building materials in mold-problem homes. The spores of different species were efficiently aerosolized by the FSSST, exhibiting a total spore release rate ranging approximately from 10(2) to 10(3) cm2/min. For all tested materials, <2% of the spores on the contaminated surface were released during the tests. The airborne spore concentration estimated from the release rate data was found in most cases to be significantly greater than the concentration actually measured in these environments with simultaneous air sampling. The results suggest that the FSSST can be used for the assessment of maximum potential exposure to airborne spores released from identified sources in homes. PRACTICAL IMPLICATIONS A recently developed FSSST was found to be suitable to measure the aerosolization potential of indoor fungal sources at the most favorable release conditions. The FSSST generates the data that allows assessing the strength of mold sources in homes with respect to their maximum ability to contaminate indoor air with fungi. The novel approach bridges two conventional methods, the air sampling and the direct source evaluation (e.g. swab sampling), thus providing a better representation of the airborne fungal exposure than these methods individually. The device prototype can be used for evaluating the effectiveness of environmental interventions by taking samples before and after the intervention. As a broader application, the FSSST can be utilized for assessing the release of various hazardous biological and non-biological particles from contaminated surfaces.
Collapse
|
22
|
Limitations of monoclonal antibodies for monitoring of fungal aerosols using Penicillium brevicompactum as a model fungus. J Immunol Methods 2004; 283:235-45. [PMID: 14659915 DOI: 10.1016/j.jim.2003.09.012] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Molds are ubiquitous in every environment and many species have been recently associated with an increase in opportunistic infections in immunocompromised patients or the exacerbation of asthmatic episodes in allergic patients. The degree of environmental contamination with fungi thus needs to be monitored and in this study we report the development of a monoclonal antibody (mAb)-mediated enzyme-linked immunosorbent assay (ELISA) for the detection of spores of Penicillium brevicompactum in experimental model aerosols. In addition, we have investigated the influence of different parameters of air sampling and sample recovery on ELISA performance. MAbs were produced with standard hybridoma techniques and cross-reactivities were determined against spores of 53 fungal species by indirect ELISA. Standardized experimental fungal aerosols were collected with the Button Personal Inhalable Aerosol Sampler onto polycarbonate or polytetrafluoroethylene filters (PTFE) and the effects of different extraction buffers and filter agitation methods during sample processing on spore recovery and ELISA detection were investigated. Five mAbs were produced and all of them cross-reacted with several of 31 related Aspergillus, Penicillium and Eurotium species. However, cross-reactivities with 21 non-related fungi were rare. Spores were recovered in much higher numbers from polycarbonate filters (PFs) than from polytetrafluoroethylene filters. Optical densities (ODs) in ELISA were higher for spores collected into carbonate coating buffer (CCB) than phosphate-buffered saline (PBS). Filter bath sonication following filter vortexing had no positive effects on ELISA sensitivity. The cross-reactivity patterns of mAbs suggest that Aspergillus and Penicillium species share multiple antigens. Quantitative ELISA results for fungal aerosols were found to be influenced by differential sample processing and thus method standardization will be essential to maintain the comparability of immunometric monitoring results.
Collapse
|
23
|
Comparison of filter bag, cyclonic, and wet dust collection methods in vacuum cleaners. AIHAJ : A JOURNAL FOR THE SCIENCE OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH AND SAFETY 2001; 62:573-83. [PMID: 11669383 DOI: 10.1080/15298660108984656] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
In this study, methods were developed for comparative evaluation of three primary dust collection methods employed in vacuum cleaners: filter bag, cyclonic, and wet primary dust collection. The dry collectors were evaluated with KCl test aerosols that are commonly used in filter testing. However, these aerosols cannot be used for evaluating wet collectors due to their hygroscopicity. Therefore, the wet collectors were evaluated with nonhygroscopic test particles. Both types of test aerosol indicated similar collection efficiencies in tests with dry collectors. The data show that high initial collection efficiency can be achieved by any one of the three dust collection methods: up to 50% for 0.35 microm particles, and close to 100% for 1.0 microm and larger particles. The degree of dependence of the initial collection efficiency on airflow rate was strongly related to the type and manufacturing of the primary dust collector. Collection efficiency decreased most with decreasing flow rate for the tested wet collectors. The tested cyclonic and wet collectors showed high reentrainment of already collected dust particles. After the filter bag collectors had been loaded with test dust, they also reemitted particles. The degree of reentrainment from filter bags depends on the particulate load and the type of filter material used. Thus, the overall particle emissions performance of a vacuum cleaner depends not only on the dust collection efficiency of the primary collector and other filtration elements employed, but also on the degree of reentrainment of already collected particles.
Collapse
|
24
|
Comparison of the indoor air quality in mould damaged and reference buildings in a subarctic climate. Cent Eur J Public Health 2001; 9:133-9. [PMID: 11505735] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/21/2023]
Abstract
The purpose of this study was to search for objective parameters most relevant to indicate microbial problems of buildings in cold climate. Various indoor characteristics were compared in nine buildings with known history of moisture problems and visible mould (index) and in nine matched reference buildings. The concentrations of airborne viable fungal had a clear difference between the two groups of buildings. In this study, airborne concentrations of viable bacteria, formaldehyde, total volatile organic compounds (TVOC) and the occurrence of house dust mites in these index buildings were compared with the levels of the pollutants in matched reference buildings. Fungal growth and flora on moist building materials were also studied. The concentrations of TVOC were slightly higher in the index buildings than in the reference buildings. However, the differences in the concentrations or appearance of any of the studied pollutants were not significant. These parameters do not seem to be relevant indicators of microbial growth or surrogates of microbial exposure. Thus, fungal concentration and composition of fungal genera in the air still seems to be the best indicator for moisture problems among the studied pollutants. In the moist building materials, some fungal genera, such as Ulocladium and Chaetophoma were detected that were not found in indoor air showing that building material samples give additional information on the microflora of the building.
Collapse
|
25
|
Particle emission characteristics of filter-equipped vacuum cleaners. AIHAJ : A JOURNAL FOR THE SCIENCE OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH AND SAFETY 2001; 62:482-93. [PMID: 11549143 DOI: 10.1080/15298660108984651] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
Industrial vacuum cleaners with final high-efficiency particulate air (HEPA) filters traditionally have been used for cleanup operations in which all of the nozzle-entrained dust must be collected with high efficiency, for example, after lead-based paint abatement in homes. In this study household vacuum cleaners ranging from $70 to $650 and an industrial vacuum cleaner costing more than $1400 were evaluated relative to their collection efficiency immediately after installing new primary dust collectors in them. Using newly developed testing technology, some of the low-cost household vacuum cleaners equipped with a final HEPA filter were found to have initial overall filtration efficiencies comparable to those of industrial vacuum cleaners equipped with a final HEPA filter. The household vacuum cleaners equipped with a final HEPA filter efficiently collect about 100% of the dry dust entrained by the nozzle. For extensive cleaning efforts and for vacuum cleaning of wet surfaces, however, industrial vacuum cleaners may have an advantage, including ruggedness and greater loading capacity. The methods and findings of this study are applicable to field evaluations of vacuum cleaners.
Collapse
|
26
|
Test methods for evaluating the filtration and particulate emission characteristics of vacuum cleaners. AIHAJ : A JOURNAL FOR THE SCIENCE OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH AND SAFETY 2001; 62:313-21. [PMID: 11434437 DOI: 10.1080/15298660108984633] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
The overall filtration efficiency of a vacuum cleaner traditionally has been tested by placing the vacuum cleaner in a test chamber and measuring aerosol concentrations at the chamber inlet and outlet. The chamber test method was refined and validated in this study. However, this chamber test method shows an overall filtration efficiency of close to 100% for most of the industrial vacuum cleaners and for most of the newly developed household vacuum cleaners of midprice range or higher because all these vacuum cleaners have a high-efficiency particulate air (HEPA) or other highly efficient filter installed at the exhaust. A new test method was therefore developed through which the vacuum cleaner was probed in various internal locations so that the collection efficiency of the individual components could be determined. For example, the aerosol concentration upstream of the final HEPA filter can thus be measured, which permits one to estimate the life expectancy of this expensive component. The probed testing method is particularly suitable for field evaluations of vacuum cleaners because it uses compact, battery-operated optical particle size spectrometers with internal data storage. Both chamber and probed tests gave the same results for the aerosol filtration efficiency. The probed testing method, however, also gives information on the performance of the individual components in a vacuum cleaner. It also can be used to determine the dust pickup efficiency and the degree of reaerosolization of particles collected in the vacuum cleaner.
Collapse
|
27
|
Performance of Air-O-Cell, Burkard, and Button Samplers for total enumeration of airborne spores. AIHAJ : A JOURNAL FOR THE SCIENCE OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH AND SAFETY 2000; 61:855-64. [PMID: 11192220 DOI: 10.1080/15298660008984598] [Citation(s) in RCA: 39] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
Performance of three devices used for the total enumeration of airborne spores-the Air-O-Cell sampling cassette, the Burkard personal volumetric air sampler, and the Button Aerosol Sampler--was evaluated under controlled laboratory conditions. The first two are glass-slide impactors; the third collects spores on a filter. The samplers were challenged with 0.44-5.10 microm polystyrene latex particles and five microorganisms of 0.84-3.07 microm mean aerodynamic diameter: Streptomyces albus, Bacillus subtilis, Cladosporium cladosporioides, Penicillium brevicompactum, and Penicillium melinii. An optical particle counter measured the particle concentrations upstream and downstream of each sampler, and thus determined the physical collection efficiency of the three samplers. Collection efficiency of the Button Aerosol Sampler was close to 100% for the entire particle size range studied. The cut-off size of each impactor was 2.3-2.4 microm. Acridine orange (with epifluorescent microscopy) and lactophenol cotton blue (with bright light microscopy) staining techniques were used for the microscopic enumeration of spores. No significant difference in microscopic counts was found (at the 95% significance level) when using these two techniques with the Button Aerosol Sampler filters. When the lactophenol cotton blue staining was used to compare total microbial counts yielded by all three samplers, the Button Sampler showed significantly higher counts for the smaller size microorganisms (B. subtilis and C. cladosporioides). For the larger microorganisms (P. brevicompactum and P. melinii) all three samplers yielded similar results. Uniformity of particle deposition on the collection surface was highest for the Button Aerosol Sampler due to the design of its inlet. Thus, the filter collection method used with the Button Aerosol Sampler is suitable and can be advantageous for the enumeration of total airborne spores.
Collapse
|
28
|
|
29
|
Control of exposure to airborne viable microorganisms during remediation of moldy buildings; report of three case studies. AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL 1998; 59:455-60. [PMID: 9697292 DOI: 10.1080/15428119891010190] [Citation(s) in RCA: 24] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Three different techniques for reducing exposure to microorganisms were tested during remediation of moldy buildings. Concentrations of spores (fungi and actinomycetes) were determined by filter sampling before, during, and after remediation. The local exhaust method used for asbestos dismantling was the most effective control method. In the construction zone, concentrations of microorganisms were 4-25 times higher during remediation than before it. In the adjacent area no increase in concentrations was seen. When the construction zone was placed under negative pressure with a fan and isolated with a plastic barrier, concentrations of microorganisms were about 100 times higher there during remediation work. Nevertheless, levels remained low in the adjacent area. The use of a portable exhaust fan with a side-draft hood decreased concentrations of fungi to one-tenth compared with demolition without the control technology. Furthermore, this method prevented the migration of fungal spores from the construction zone to the adjacent area, although it was less effective in prevention of actinomycete spore migration. It also decreased the levels of microorganisms in the construction zone below the preconstruction level within 2 hours. This study showed that levels of airborne microorganisms, including from the working area to adjacent area, can be reduced with commonly used dust control methods during demolition work. However, microorganism levels in the construction zone remained elevated. Therefore, personal protection of construction workers is needed even with control techniques.
Collapse
|
30
|
Field testing of new aerosol sampling method with a porous curved surface as inlet. AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL 1997; 58:713-9. [PMID: 9342831 DOI: 10.1080/15428119791012351] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
A new aerosol sampling method, utilizing a porous curved surface as the sampling inlet, has recently been developed. Previous laboratory evaluations of this method have demonstrated its important features, such as low wind sensitivity and good filter collection uniformity. In this study a prototype incorporating the new method was evaluated in the field as a stationary and personal sampling device. The small sampler, utilizing a 25-mm filter is called the button aerosol sampler and was evaluated for collecting total airborne dust and fungal spores. The study was performed in nine poorly maintained inner-city houses during environmental cleanups at different cleanliness levels. The button sampler was used in parallel with the standard 37-mm closed-face filter cassette. Four collocated samplers of each type were tested at all sites as stationary samplers, and three samplers of each type were tested at two sites as personal samplers. Aerosol samples were collected on filters and analyzed using the gravimetric method for total dust and epifluorescence microscopy for fungal spores. The average particle concentration values measured with the button sampler and with the standard sampling cassette were found to correlate well within ranges of 10(1)-10(3) micrograms/m3 for total dust and 10(3)-10(5) spores/m3 for airborne fungi. The measurement results obtained with the new button sampler showed lower intersample variations of the measured concentration levels and higher uniformity of the particle deposits on the filters than those obtained with the standard cassette.
Collapse
|
31
|
Exposure to airborne microbes during the repair of moldy buildings. AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL 1996; 57:279-84. [PMID: 8776199 DOI: 10.1080/15428119691015016] [Citation(s) in RCA: 36] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Concentrations of airborne microbes, studied during the repair of seven moldy buildings, showed that concentrations of airborne fungi increased during the repair work. This was especially true during the demolition of moldy building materials, even though the total dust levels remained low. Concentrations of viable fungi sampled with a six-stage cascade impactor were 10(3) - > 1.9 x 10(5) cfu/m3, and the total concentrations of fungal propagules, as determined by the Camnea method (i.e., air filtration method with epifluorescence microscopic counting of acridine-stained organisms) showed 10(5)-10(6) counts/m3 during the demolition. Penicillium was the main genus throughout. Concentrations of viable total bacteria also increased, but this change proved less noticeable than that of the fungi. However, rather high concentrations of viable actinomycetes up to 10(4) cfu/m3 were detected during the demolition. Results show that construction workers are exposed to high concentrations of microbes, perhaps causing health problems. Thus, personal protection of both the respiratory system and eyes is strongly recommended for workers as they repair moldy buildings. In addition, the repair room should be isolated from other areas to protect occupants or any other people present.
Collapse
|
32
|
Strategic information systems planning workshops: Lessons from three cases. INTERNATIONAL JOURNAL OF INFORMATION MANAGEMENT 1994. [DOI: 10.1016/0268-4012(94)90095-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
33
|
|