1
|
Electrocautery-induced Inappropriate Implantable Cardiac Defibrillator Shock. THE ISRAEL MEDICAL ASSOCIATION JOURNAL : IMAJ 2024; 26:245-246. [PMID: 38616671] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 04/16/2024]
|
2
|
Cardioneuroablation as a strategy to prevent pacemaker implantation in young patients with vasovagal syncope. IJC HEART & VASCULATURE 2024; 51:101360. [PMID: 38379634 PMCID: PMC10877404 DOI: 10.1016/j.ijcha.2024.101360] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2023] [Revised: 01/22/2024] [Accepted: 02/07/2024] [Indexed: 02/22/2024]
Abstract
Background Cardioneuroablation (CNA) is an ablation technique that targets epicardial ganglionic plexi to reduce syncope burden and avoid pacemaker implantation in patients with cardioinhibitory vasovagal syncope (VVS). This study aims to demonstrate feasibility and safety of CNA in high-risk refractory VVS patients using continuous monitoring with an implantable loop recorder (ILR). Methods Data was collected prospectively for patients undergoing CNA. Patients were required to have recurrent syncope with documented asystole, refractory to conservative measures. Ganglionic plexi (GPs) were identified by fragmented signals and high frequency stimulation (HFS). Ablation was performed until loss of positive response to HFS, Wenckebach cycle shortening was achieved, or an increase in sinus rate of > 20 bpm. Follow-up was performed through remote and clinic follow-up of their ILRs. Results Between December 2020 and July 2023 six patients (mean age 29 ± 3, 67 % female)underwent CNA. The baseline heart rate and Wenckebach cycle length was 63.2 ± 15 bpm and 582 ms before and 91 ± 5 bpm and 358 ms after ablation respectively. During a median follow-up of 13.4 months, 3/5 patients had no further syncopal episodes, 1 had a recurrence, underwent repeat CNA with no further episodes at 1 year, and 1 had 5 syncopal events, which was a dramatic reduction from nearly daily episodes pre-CNA. There were no procedure related complications. Conclusions A dramatic reduction in documented pauses and syncope burden was noted post CNA. Appropriate patient selection with rigorous objective follow-up in an experienced center is necessary. Larger studies are required to confirm these findings.
Collapse
|
3
|
Cryocure-VT: the safety and effectiveness of ultra-low-temperature cryoablation of monomorphic ventricular tachycardia in patients with ischaemic and non-ischaemic cardiomyopathies. Europace 2024; 26:euae076. [PMID: 38582974 PMCID: PMC10998960 DOI: 10.1093/europace/euae076] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2024] [Accepted: 03/18/2024] [Indexed: 04/08/2024] Open
Abstract
AIMS The ultra-low-temperature cryoablation (ULTC) ablation system using -196°C N2 cryogen has been reported to create lesions with freeze duration-dependent depth titratable to over 10 mm with minimum attenuation by scar. Cryocure-VT (NCT04893317) was a first-in-human clinical trial evaluating the safety and efficacy of a novel, purpose-built ULTC catheter in endocardial ablation of scar-dependent ventricular tachycardias (VTs). METHODS AND RESULTS This prospective, multi-centre study enrolled patients referred for de novo or second ablations of recurrent monomorphic VT of both ischaemic and non-ischaemic aetiologies. Primary safety and efficacy endpoints of the study were freedom from device- or procedure-related major adverse events (MAEs) up to 30 days post-ablation, acute non-inducibility of clinical VTs at the end of the procedure, and freedom from sustained VT or implantable defibrillator intervention at 6 months. Ultra-low-temperature cryoablation was performed in 64 patients (age 67 ± 11 years, 78% ischaemic, ejection fraction = 35 ± 10%) at 9 centres. The primary acute effectiveness endpoint was achieved in 94% (51/54) of patients in whom post-ablation induction was attempted. There were no protocol-defined MAEs; four procedure-related serious adverse events resolved without clinical sequelae. At 6-month follow-up, 38 patients (60.3%) remained VT-free, and freedom from defibrillator shock was 81.0%, with no significant difference between ischaemic and non-ischaemic cohorts. In 47 patients with defibrillator for at least 6 months prior to the ablation, the VT burden was reduced from median of 4, inter-quartile range (IQR, 1-9) to 0, IQR (0-2). CONCLUSION In this first-in-human multi-centre experience, endocardial ULTC ablation of monomorphic VT appears safe and effective in patients with both ischaemic-cardiomyopathy and non-ischaemic-cardiomyopathy. CLINICAL TRIAL REGISTRATION NCT04893317.
Collapse
|
4
|
Atrial Fibrillation Burden: Impact on Stroke Risk and Beyond. MEDICINA (KAUNAS, LITHUANIA) 2024; 60:536. [PMID: 38674182 PMCID: PMC11051719 DOI: 10.3390/medicina60040536] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/01/2024] [Revised: 03/07/2024] [Accepted: 03/14/2024] [Indexed: 04/28/2024]
Abstract
Atrial fibrillation (AF) is an important independent risk factor for stroke. Current guidelines handle AF as a binary entity with risk driven by the presence of clinical risk factors, which guides the decision to treat with an oral anticoagulant. Recent studies in the literature suggest a dose-response relationship between AF burden and stroke risk, in both clinical AF and subclinical atrial fibrillation (SCAF), which differs from current guidance to disregard burden and utilize clinical risk scores alone. Within clinical classification and at the same risk levels in various scores, the risk of stroke increases with AF burden. This opens the possibility of incorporating burden into risk profiles, which has already shown promise. Long-term rhythm monitoring is needed to elucidate SCAF in patients with stroke. Recent data from randomized trials are controversial regarding whether there is an independent risk from AF episodes with a duration of less than 24 h, including the duration of SCAF greater than six minutes but less than 24 h.
Collapse
|
5
|
Ultra-Low-Temperature Cryoablation for Ventricular Tachycardia: An Early Single-Centre Report of Acute Results. CJC Open 2024; 6:560-568. [PMID: 38559338 PMCID: PMC10980890 DOI: 10.1016/j.cjco.2023.11.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Accepted: 11/10/2023] [Indexed: 04/04/2024] Open
Abstract
Background Endocardial catheter ablation for ventricular tachycardia (VT) may fail because of the inability to deliver transmural lesions. Ultra-low-temperature cryoablation (ULTC) uses near-critical nitrogen and can generate temperatures as low as -196 °C. We report a series of 18 patients who underwent ULTC at the McGill University Health Centre (MUHC), representing the largest single-centre experience to date. Methods Eighteen patients with monomorphic drug-refractory VT underwent VT ablation with ULTC at our institution as part of the first-in-human CryoCure-VT trial (NCT04893317). After voltage map, the mapping catheter was replaced with the ULTC catheter, and lesions were applied over a fixed duration of time (60-180 seconds), followed by a 60-second thaw and another application at the original duration (freeze-thaw-freeze). Duration of ablation time was selected depending on the wall thickness of the left ventricle monitored with intracardiac echo to achieve tissue depths of 4.5 to 7.5 mm. Results Baseline left ventricular ejection fraction was 32%, mean age 71 years, 94% were male. A total of 32 sustained VTs were induced in 16 of 18 patients. A total of 177 cryoablation lesions were delivered (9.8 lesions per patient). Of the 16 patients with inducible VT, 15 (94%) were rendered noninducible postablation, and 1 was inducible only for a nonclinical VT. Complications included 1 pericardial effusion that required drainage. From 18 patients, 16 (89%) were discharged within the first 24 hours postablation. Conclusions ULTC is feasible and permits acute control of monomorphic VT during VT ablation procedures in drug-refractory patients.
Collapse
|
6
|
A Case of Loss of Ventricular Pacing Due to Inappropriate Hysteresis Function Programming After AV Node Ablation. CJC Open 2024; 6:62-64. [PMID: 38313342 PMCID: PMC10837710 DOI: 10.1016/j.cjco.2023.11.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Accepted: 11/13/2023] [Indexed: 02/06/2024] Open
|
7
|
High-power short-duration versus low-power long-duration ablation for pulmonary vein isolation: A substudy of the AWARE randomized controlled trial. J Cardiovasc Electrophysiol 2024; 35:136-145. [PMID: 37990448 DOI: 10.1111/jce.16123] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 10/21/2023] [Accepted: 10/26/2023] [Indexed: 11/23/2023]
Abstract
INTRODUCTION Pulmonary vein isolations (PVI) are being performed using a high-power, short-duration (HPSD) strategy. The purpose of this study was to compare the clinical efficacy and safety outcomes of an HPSD versus low-power, long-duration (LPLD) approach to PVI in patients with paroxysmal atrial fibrillation (AF). METHODS Patients were grouped according to a HPSD (≥40 W) or LPLD (≤35 W) strategy. The primary endpoint was the 1-year recurrence of any atrial arrhythmia lasting ≥30 s, detected using three 14-day ambulatory continuous ECG monitoring. Procedural and safety endpoints were also evaluated. The primary analysis were regression models incorporating propensity scores yielding adjusted relative risk (RRa ) and mean difference (MDa ) estimates. RESULTS Of the 398 patients included in the AWARE Trial, 173 (43%) underwent HPSD and 225 (57%) LPLD ablation. The distribution of power was 50 W in 75%, 45 W in 20%, and 40 W in 5% in the HPSD group, and 35 W with 25 W on the posterior wall in the LPLD group. The primary outcome was not statistically significant at 30.1% versus 22.2% in HPSD and LPLD groups with RRa 0.77 (95% confidence interval [CI]) 0.55-1.10; p = .165). The secondary outcome of repeat catheter ablation was not statistically significant at 6.9% and 9.8% (RRa 1.59 [95% CI 0.77-3.30]; p = .208) respectively, nor was the incidence of any ECG documented AF during the blanking period: 1.7% versus 8.0% (RRa 3.95 [95% CI 1.00-15.61; p = .049) in the HPSD versus LPLD group respectively. The total procedure time was significantly shorter in the HPSD group (MDa 97.5 min [95% CI 84.8-110.4)]; p < .0001) with no difference in adjudicated serious adverse events. CONCLUSIONS An HPSD strategy was associated with significantly shorter procedural times with similar efficacy in terms of clinical arrhythmia recurrence. Importantly, there was no signal for increased harm with a HPSD strategy.
Collapse
|
8
|
Adaptive versus conventional cardiac resynchronisation therapy in patients with heart failure (AdaptResponse): a global, prospective, randomised controlled trial. Lancet 2023; 402:1147-1157. [PMID: 37634520 DOI: 10.1016/s0140-6736(23)00912-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 05/01/2023] [Accepted: 05/04/2023] [Indexed: 08/29/2023]
Abstract
BACKGROUND Continuous automatic optimisation of cardiac resynchronisation therapy (CRT), stimulating only the left ventricle to fuse with intrinsic right bundle conduction (synchronised left ventricular stimulation), might offer better outcomes than conventional CRT in patients with heart failure, left bundle branch block, and normal atrioventricular conduction. This study aimed to compare clinical outcomes of adaptive CRT versus conventional CRT in patients with heart failure with intact atrioventricular conduction and left bundle branch block. METHODS This global, prospective, randomised controlled trial was done in 227 hospitals in 27 countries across Asia, Australia, Europe, and North America. Eligible patients were aged 18 years or older with class 2-4 heart failure, an ejection fraction of 35% or less, left bundle branch block with QRS duration of 140 ms or more (male patients) or 130 ms or more (female patients), and a baseline PR interval 200 ms or less. Patients were randomly assigned (1:1) via block permutation to adaptive CRT (an algorithm providing synchronised left ventricular stimulation) or conventional biventricular CRT using a device programmer. All patients received device programming but were masked until procedures were completed. Site staff were not masked to group assignment. The primary outcome was a composite of all-cause death or intervention for heart failure decompensation and was assessed in the intention-to-treat population. Safety events were collected and reported in the intention-to-treat population. This study is registered with ClinicalTrials.gov, NCT02205359, and is closed to accrual. FINDINGS Between Aug 5, 2014, and Jan 31, 2019, of 3797 patients enrolled, 3617 (95·3%) were randomly assigned (1810 to adaptive CRT and 1807 to conventional CRT). The futility boundary was crossed at the third interim analysis on June 23, 2022, when the decision was made to stop the trial early. 1568 (43·4%) of 3617 patients were female and 2049 (56·6%) were male. Median follow-up was 59·0 months (IQR 45-72). A primary outcome event occurred in 430 of 1810 patients (Kaplan-Meier occurrence rate 23·5% [95% CI 21·3-25·5] at 60 months) in the adaptive CRT group and in 470 of 1807 patients (25·7% [23·5-27·8] at 60 months) in the conventional CRT group (hazard ratio 0·89, 95% CI 0·78-1·01; p=0·077). System-related adverse events were reported in 452 (25·0%) of 1810 patients in the adaptive CRT group and 440 (24·3%) of 1807 patients in the conventional CRT group. INTERPRETATION Compared with conventional CRT, adaptive CRT did not significantly reduce the incidence of all-cause death or intervention for heart failure decompensation in the included population of patients with heart failure, left bundle branch block, and intact AV conduction. Death and heart failure decompensation rates were low with both CRT therapies, suggesting a greater response to CRT occurred in this population than in patients in previous trials. FUNDING Medtronic.
Collapse
|
9
|
Ventricular Tachycardia and ICD Therapy Burden With Catheter Ablation Versus Escalated Antiarrhythmic Drug Therapy. JACC Clin Electrophysiol 2023; 9:808-821. [PMID: 37380314 DOI: 10.1016/j.jacep.2023.01.030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Revised: 01/24/2023] [Accepted: 01/26/2023] [Indexed: 06/30/2023]
Abstract
BACKGROUND Catheter ablation improves ventricular tachycardia (VT) event-free (time to event) survival in patients with antiarrhythmic drug (AAD)-refractory VT and previous myocardial infarction (MI). The effects of ablation on recurrent VT and implantable cardioverter-defibrillator (ICD) therapy (burden) have yet to be investigated. OBJECTIVES This study sought to compare the VT and ICD therapy burden following treatment with either ablation or escalated AAD therapy among patients with VT and previous MI in the VANISH (Ventricular tachycardia AblatioN versus escalated antiarrhythmic drug therapy in ISchemic Heart disease) trial. METHODS The VANISH trial randomized patients with previous MI and VT despite initial AAD therapy to either escalated AAD treatment or catheter ablation. VT burden was defined as the total number of VT events treated with ≥1 appropriate ICD therapy. Appropriate ICD therapy burden was defined as the total number of appropriate shocks or antitachycardia pacing therapies (ATPs) delivered. The Anderson-Gill recurrent event model was used to compare burden between the treatment arms. RESULTS Of the 259 enrolled patients (median age, 69.8 years; 7.0% women), 132 patients were randomized to ablation and 129 patients were randomized to escalated AAD therapy. Over 23.4 months of follow-up, ablation-treated patients had a 40% lower shock-treated VT event burden and a 39% lower appropriate shock burden compared with patients who received escalated AAD therapy (P <0.05 for all). A reduction in VT burden, ATP-treated VT event burden, and appropriate ATP burden among ablation patients was only demonstrated in the stratum of patients with amiodarone-refractory VT (P <0.05 for all). CONCLUSIONS Among patients with AAD-refractory VT and a previous MI, catheter ablation reduced shock-treated VT event burden and appropriate shock burden compared with escalated AAD therapy. There was also lower VT burden, ATP-treated VT event burden, and appropriate ATP burden among ablation-treated patients; however, the effect was limited to patients with amiodarone-refractory VT.
Collapse
|
10
|
Standard vs Augmented Ablation of Paroxysmal Atrial Fibrillation for Reduction of Atrial Fibrillation Recurrence: The AWARE Randomized Clinical Trial. JAMA Cardiol 2023; 8:475-483. [PMID: 36947030 PMCID: PMC10034661 DOI: 10.1001/jamacardio.2023.0212] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Accepted: 01/24/2023] [Indexed: 03/23/2023]
Abstract
Importance Recurrent atrial fibrillation (AF) commonly occurs after catheter ablation and is associated with patient morbidity and health care costs. Objective To evaluate the superiority of an augmented double wide-area circumferential ablation (WACA) compared with a standard single WACA in preventing recurrent atrial arrhythmias (AA) (atrial tachycardia, atrial flutter, or atrial fibrillation [AF]) in patients with paroxysmal AF. Design, Setting, and Participants This was a pragmatic, multicenter, prospective, randomized, open, blinded end point superiority clinical trial conducted at 10 university-affiliated centers in Canada. The trial enrolled patients 18 years and older with symptomatic paroxysmal AF from March 2015 to May 2017. Analysis took place between January and April 2022. Analyses were intention to treat. Interventions Patients were randomized (1:1) to receive radiofrequency catheter ablation for pulmonary vein isolation with either a standard single WACA or an augmented double WACA. Main Outcomes and Measures The primary outcome was AA recurrence between 91 and 365 days postablation. Patients underwent 42 days of ambulatory electrocardiography monitoring after ablation. Secondary outcomes included need for repeated catheter ablation and procedural and safety variables. Results Of 398 patients, 195 were randomized to the single WACA (control) arm (mean [SD] age, 60.6 [9.3] years; 65 [33.3%] female) and 203 to the double WACA (experimental) arm (mean [SD] age, 61.5 [9.3] years; 66 [32.5%] female). Overall, 52 patients (26.7%) in the single WACA arm and 50 patients (24.6%) in the double WACA arm had recurrent AA at 1 year (relative risk, 0.92; 95% CI, 0.66-1.29; P = .64). Twenty patients (10.3%) in the single WACA arm and 15 patients (7.4%) in the double WACA arm underwent repeated catheter ablation (relative risk, 0.72; 95% CI, 0.38-1.36). Adjudicated serious adverse events occurred in 13 patients (6.7%) in the single WACA arm and 14 patients (6.9%) in the double WACA arm. Conclusions and Relevance In this randomized clinical trial of patients with paroxysmal AF, additional ablation by performing a double ablation lesion set did not result in improved freedom from recurrent AA compared with a standard single ablation set. Trial Registration ClinicalTrials.gov Identifier: NCT02150902.
Collapse
|
11
|
Association of the Timing and Extent of Cardiac Implantable Electronic Device Infections With Mortality. JAMA Cardiol 2023; 8:484-491. [PMID: 37017943 PMCID: PMC10077129 DOI: 10.1001/jamacardio.2023.0467] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/13/2022] [Accepted: 02/06/2023] [Indexed: 04/06/2023]
Abstract
Importance Cardiac implantable electronic device (CIED) infection is a potentially devastating complication with an estimated 12-month mortality of 15% to 30%. The association of the extent (localized or systemic) and timing of infection with all-cause mortality has not been established. Objective To evaluate the association of the extent and timing of CIED infection with all-cause mortality. Design, Setting, and Participants This prospective observational cohort study was conducted between December 1, 2012, and September 30, 2016, in 28 centers across Canada and the Netherlands. The study included 19 559 patients undergoing CIED procedures, 177 of whom developed an infection. Data were analyzed from April 5, 2021, to January 14, 2023. Exposures Prospectively identified CIED infections. Main Outcomes and Measures Time-dependent analysis of the timing (early [≤3 months] or delayed [3-12 months]) and extent (localized or systemic) of infection was performed to determine the risk of all-cause mortality associated with CIED infections. Results Of 19 559 patients undergoing CIED procedures, 177 developed a CIED infection. The mean (SD) age was 68.7 (12.7) years, and 132 patients were male (74.6%). The cumulative incidence of infection was 0.6%, 0.7%, and 0.9% within 3, 6, and 12 months, respectively. Infection rates were highest in the first 3 months (0.21% per month), reducing significantly thereafter. Compared with patients who did not develop CIED infection, those with early localized infections were not at higher risk for all-cause mortality (no deaths at 30 days [0 of 74 patients]: adjusted hazard ratio [aHR], 0.64 [95% CI, 0.20-1.98]; P = .43). However, patients with early systemic and delayed localized infections had an approximately 3-fold increase in mortality (8.9% 30-day mortality [4 of 45 patients]: aHR, 2.88 [95% CI, 1.48-5.61]; P = .002; 8.8% 30-day mortality [3 of 34 patients]: aHR, 3.57 [95% CI, 1.33-9.57]; P = .01), increasing to a 9.3-fold risk of death for those with delayed systemic infections (21.7% 30-day mortality [5 of 23 patients]: aHR, 9.30 [95% CI, 3.82-22.65]; P < .001). Conclusions and Relevance Findings suggest that CIED infections are most common within 3 months after the procedure. Early systemic infections and delayed localized infections are associated with increased mortality, with the highest risk for patients with delayed systemic infections. Early detection and treatment of CIED infections may be important in reducing mortality associated with this complication.
Collapse
|
12
|
Abstract
BACKGROUND Atrial fibrillation is a chronic, progressive disorder, and persistent forms of atrial fibrillation are associated with increased risks of thromboembolism and heart failure. Catheter ablation as initial therapy may modify the pathogenic mechanism of atrial fibrillation and alter progression to persistent atrial fibrillation. METHODS We report the 3-year follow-up of patients with paroxysmal, untreated atrial fibrillation who were enrolled in a trial in which they had been randomly assigned to undergo initial rhythm-control therapy with cryoballoon ablation or to receive antiarrhythmic drug therapy. All the patients had implantable loop recorders placed at the time of trial entry, and evaluation was conducted by means of downloaded daily recordings and in-person visits every 6 months. Data regarding the first episode of persistent atrial fibrillation (lasting ≥7 days or lasting 48 hours to 7 days but requiring cardioversion for termination), recurrent atrial tachyarrhythmia (defined as atrial fibrillation, flutter, or tachycardia lasting ≥30 seconds), the burden of atrial fibrillation (percentage of time in atrial fibrillation), quality-of-life metrics, health care utilization, and safety were collected. RESULTS A total of 303 patients were enrolled, with 154 patients assigned to undergo initial rhythm-control therapy with cryoballoon ablation and 149 assigned to receive antiarrhythmic drug therapy. Over 36 months of follow-up, 3 patients (1.9%) in the ablation group had an episode of persistent atrial fibrillation, as compared with 11 patients (7.4%) in the antiarrhythmic drug group (hazard ratio, 0.25; 95% confidence interval [CI], 0.09 to 0.70). Recurrent atrial tachyarrhythmia occurred in 87 patients in the ablation group (56.5%) and in 115 in the antiarrhythmic drug group (77.2%) (hazard ratio, 0.51; 95% CI, 0.38 to 0.67). The median percentage of time in atrial fibrillation was 0.00% (interquartile range, 0.00 to 0.12) in the ablation group and 0.24% (interquartile range, 0.01 to 0.94) in the antiarrhythmic drug group. At 3 years, 8 patients (5.2%) in the ablation group and 25 (16.8%) in the antiarrhythmic drug group had been hospitalized (relative risk, 0.31; 95% CI, 0.14 to 0.66). Serious adverse events occurred in 7 patients (4.5%) in the ablation group and in 15 (10.1%) in the antiarrhythmic drug group. CONCLUSIONS Initial treatment of paroxysmal atrial fibrillation with catheter cryoballoon ablation was associated with a lower incidence of persistent atrial fibrillation or recurrent atrial tachyarrhythmia over 3 years of follow-up than initial use of antiarrhythmic drugs. (Funded by the Cardiac Arrhythmia Network of Canada and others; EARLY-AF ClinicalTrials.gov number, NCT02825979.).
Collapse
|
13
|
Novel Oral Anticoagulants in Patients With Atrial Fibrillation and Moderate to Severe Mitral Stenosis: A Systematic Review. Cureus 2023; 15:e33222. [PMID: 36741597 PMCID: PMC9891397 DOI: 10.7759/cureus.33222] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/01/2023] [Indexed: 01/02/2023] Open
Abstract
The use of novel oral anticoagulants (NOAC) in patients with moderate to severe mitral stenosis (MS) and atrial fibrillation (AF) is not recommended. We aimed to evaluate the efficacy and safety of NOAC usage compared to vitamin K antagonist (VKA) in patients with moderate to severe MS and AF. We conducted a systematic review to identify articles that compared warfarin to NOAC in patients with moderate to severe MS and AF. Only four studies (two observational studies and two trials) met our search criteria and reported a total of 7529 patients with MS and AF with MS and AF, 4138 of them treated with NOAC. In both observational studies, the severity of MS was not determined, and there was heterogeneity in MS etiology. Nevertheless, both studies showed a positive signal toward the efficacy and safety of NOAC compared to VKA in this population. A randomized pilot trial (n=40) was done on patients with moderate to severe MS, and it showed further acceptable efficacy and safety for rivaroxaban use. However, a larger randomized controlled trial (n=4531) disclosed that VKA (warfarin) led to a significantly lower rate of a composite of cardiovascular events or mortality than rivaroxaban, without a higher rate of major bleeding but not fatal bleeding. Our systematic review provides exploratory information on NOAC safety and effectiveness in patients with MS; it also discourages using NOACs for patients with moderate to severe MS and supports the current treatment guidelines. However, more dedicated clinical trials evaluating the use of NOACs in moderate to severe MS are underway. They will categorically establish the safety profile and clinical effectiveness of NOAC in this high-risk population.
Collapse
|
14
|
Characterization of arrhythmia substrate to ablate persistent atrial fibrillation (COAST-AF): Randomized controlled trial design and rationale. Am Heart J 2022; 254:133-140. [PMID: 36030965 DOI: 10.1016/j.ahj.2022.08.010] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/24/2022] [Revised: 08/21/2022] [Accepted: 08/22/2022] [Indexed: 06/15/2023]
Abstract
BACKGROUND Atrial low voltage area (LVA) catheter ablation has emerged as a promising strategy for ablation of persistent atrial fibrillation (AF). It is unclear if catheter ablation of atrial LVA increases treatment success rates in patients with persistent AF. OBJECTIVE The primary aim of this trial is to assess the potential benefit of adjunctive catheter ablation of atrial LVA in addition to pulmonary vein isolation (PVI) in patients with persistent AF, when compared to PVI alone. The secondary aims are to evaluate safety outcomes, the quality of life and the healthcare resource utilization. METHODS/DESIGN A multicenter, prospective, parallel-group, 2-arm, single-blinded randomized controlled trial is under way (NCT03347227). Patients who are candidates for catheter ablation for persistent AF will be randomly assigned (1:1) to either PVI alone or PVI + atrial LVA ablation. The primary outcome is 18-month documented event rate of atrial arrhythmia (AF, atrial tachycardia or atrial flutter) post catheter ablation. Secondary outcomes include procedure-related complications, freedom from atrial arrhythmia at 12 months, AF burden, need for emergency department visits/hospitalization, need for repeat ablation for atrial arrhythmia, quality of life at 12 and 18 months, ablation time, and procedure duration. DISCUSSION Characterization of Arrhythmia Mechanism to Ablate Atrial Fibrillation (COAST-AF) is a multicenter randomized trial evaluating ablation strategies for catheter ablation. We hypothesize that catheter ablation of atrial LVA in addition to PVI will result in higher procedural success rates when compared to PVI alone in patients with persistent AF.
Collapse
|
15
|
OCEAN trial update. Am Heart J 2022; 248:169. [PMID: 34419415 DOI: 10.1016/j.ahj.2021.08.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
16
|
Augmented wide area circumferential catheter ablation for reduction of atrial fibrillation recurrence (AWARE) trial: Design and rationale. Am Heart J 2022; 248:1-12. [PMID: 35219715 DOI: 10.1016/j.ahj.2022.02.009] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 02/03/2022] [Accepted: 02/19/2022] [Indexed: 11/15/2022]
Abstract
BACKGROUND Recurrence of atrial fibrillation (AF) after a pulmonary vein isolation procedure is often due to electrical reconnection of the pulmonary veins. Repeat ablation procedures may improve freedom from AF but are associated with increased risks and health care costs. A novel ablation strategy in which patients receive "augmented" ablation lesions has the potential to reduce the risk of AF recurrence. OBJECTIVE The Augmented Wide Area Circumferential Catheter Ablation for Reduction of Atrial Fibrillation Recurrence (AWARE) Trial was designed to evaluate whether an augmented wide-area circumferential antral (WACA) ablation strategy will result in fewer atrial arrhythmia recurrences in patients with symptomatic paroxysmal AF, compared with a conventional WACA strategy. METHODS/DESIGN The AWARE trial was a multicenter, prospective, randomized, open, blinded endpoint trial that has completed recruitment (ClinicalTrials.gov NCT02150902). Patients were randomly assigned (1:1) to either the control arm (single WACAlesion set) or the interventional arm (augmented- double WACA lesion set performed after the initial WACA). The primary outcome was atrial tachyarrhythmia (AA; atrial tachycardia [AT], atrial flutter [AFl] or AF) recurrence between days 91 and 365 post catheter ablation. Patient follow-up included 14-day continuous ambulatory ECG monitoring at 3, 6, and 12 months after catheter ablation. Three questionnaires were administered during the trial- the EuroQuol-5D (EQ-5D) quality of life scale, the Canadian Cardiovascular Society Severity of Atrial Fibrillation scale, and a patient satisfaction scale. DISCUSSION The AWARE trial was designed to evaluate whether a novel approach to catheter ablation reduced the risk of AA recurrence in patients with symptomatic paroxysmal AF.
Collapse
|
17
|
Reduction in shock burden with catheter ablation versus escalated antiarrhythmic drug therapy: Insights from the VANISH trial. Europace 2022. [DOI: 10.1093/europace/euac053.364] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Abstract
Funding Acknowledgements
Type of funding sources: Public grant(s) – National budget only. Main funding source(s): 1. Canadian Institutes of Health Research (CIHR)
2. Additional financial support from St. Jude Medical and Biosense Webster
Background
Recurrent shocks for ventricular tachycardia (VT) are associated with an increased risk of heart failure and mortality and have a negative influence on quality of life. Catheter ablation has been shown to improve VT event-free survival in patients with antiarrhythmic drug (AAD)-refractory VT and prior myocardial infarction (MI); however, the effects of ablation on shock burden has yet to be investigated.
Purpose
Our primary objectives were to compare the shock-treated VT event burden and appropriate shock burden following randomization to treatment with either catheter ablation or escalated AAD therapy among VT patients with prior MI in the Ventricular tachycardia AblatioN versus escalated antiarrhythmic drug therapy in Ischemic Heart disease (VANISH) randomized trial.
Methods
Recurrent event analyses were performed using the intention-to-treat population of the VANISH trial. Shock-treated VT event burden was defined as the total number of VT events treated with ≥1 appropriate internal or external shocks. Appropriate shock burden was defined as the total number of appropriate internal and external shocks delivered, regardless of the number of VT events. All VT events and implantable cardioverter defibrillator (ICD) therapies were adjudicated by reviewers blinded to the treatment allocation. Three recurrent event models were used to compare the shock burden between treatment arms (Anderson-Gill (AG), Frailty, and Prentice, Williams, and Peterson Total Time (PWP-TT). Each model clustered by patient and accounted for competing risk of death with the Fine and Gray sub-distributions hazards model.
Results
Of the 259 patients enrolled in the VANISH trial [median age 69.8 (IQR 63.0-74.2) years, 7.0% women], 132 patients were randomized to ablation and 129 patients to escalated AAD therapy. Over a median follow-up of 23.4 (IQR 14.7-40.4) months, there were 138 shock-treated VT events [39.07 (95% CI 33.14-46.07) shock-treated VT events per 100 person-years] in the ablation arm and 218 shock-treated VT events [64.60 (95% CI 56.49–73.84) shock-treated VT events per 100 person-years] in the escalated AAD therapy arm (Figure 1). Ablation patients had a 40% lower shock-treated VT event burden (ie. number of shock-treated VT events) compared to patients randomized to escalated AAD therapy [Figure 1; AG HR 0.60 (95% 0.38-0.95)]. Further, there was also a statistically significant reduction in the appropriate shock burden (i.e. number of appropriate shocks) among ablation patients (169 appropriate shocks) compared to escalated AAD therapy patients (266 appropriate shocks) [Figure 1; AG HR 0.61 (95% CI 0.37-0.96)]. All results were consistent between the 3 recurrent event models.
Conclusion
Among patients with AAD-refractory VT and a prior MI, catheter ablation reduced shock-treated VT event burden and appropriate shock burden compared to escalated AAD therapy.
Collapse
|
18
|
BS-400-20 COMPARISON OF THE EFFICACY OF BI-V VS RV BURST ATP IN TERMINATING VT IN PATIENTS WITH NON-ISCHEMIC VS ISCHEMIC CARDIOMYOPATHY. Heart Rhythm 2022. [DOI: 10.1016/j.hrthm.2022.03.1212] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
|
19
|
CE-540-01 EFFICACY OF BURST VS RAMP ATP FOR SLOW VT. Heart Rhythm 2022. [DOI: 10.1016/j.hrthm.2022.03.631] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
20
|
Randomized Ablation-Based Rhythm-Control Versus Rate-Control Trial in Patients with Heart Failure and Atrial Fibrillation: Results from the RAFT-AF trial. Circulation 2022; 145:1693-1704. [PMID: 35313733 DOI: 10.1161/circulationaha.121.057095] [Citation(s) in RCA: 44] [Impact Index Per Article: 22.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background: Atrial fibrillation (AF) and heart failure (HF) frequently coexist and can be challenging to treat. Pharmacologic based rhythm-control of AF has not proven to be superior to rate-control. Ablation-based rhythm-control was compared to rate-control to evaluate if clinical outcomes in patients with HF and AF could be improved. Methods: This was a multicenter, open-label trial with blinded outcome evaluation using a central adjudication committee. Patients with high burden paroxysmal (>4 episodes in six months) or persistent (duration < three years) AF, New York Heart Association class II-III HF, and elevated NT-proBNP were randomized to ablation-based rhythm-control or rate-control. The primary outcome was a composite of all-cause mortality and all HF events, with a minimum follow up of two years. Secondary outcomes included left ventricular ejection fraction (LVEF), six-minute walk test and NT-proBNP. Quality of life was measured using the Minnesota Living with Heart Failure Questionnaire (MLHFQ) and the AF Effect on quality of life (AFEQT). The primary analysis was time-to-event using Cox proportional hazards modeling. The trial was stopped early due to a determination of apparent futility by the Data Safety Monitoring Committee. Results: From December 1, 2011, to January 20, 2018, 411 patients were randomized to ablation-based rhythm-control (n=214) or rate-control (n=197). The primary outcome occurred in 50 (23.4%) patients in the ablation-based rhythm-control group and 64 (32.5%) patients in the rate-control group (hazard ratio 0.71 95% CI (0.49, 1.03), p=0.066). LVEF increased in the ablation-based group (10.1±1.2% vs 3.8±1.2%, p=0.017); six-minute walk distance improved (44.9±9.1 meters 27.5±9.7 meters, p=0.025) and NT-proBNP demonstrated a decrease (mean change -77.1% vs -39.2%, p<0.0001). MLHFQ demonstrated greater improvement in the ablation-based rhythm-control group (LSMD of -5.4, 95%CI (-10.5, -0.3), p=0.0036), as did the AFEQT score (LSMD of 6.2, 95%CI (1.7, 10.7), p=0.0005). Serious adverse events were observed in 50% of patients in both treatment groups. Conclusions: In patients with high burden AF and HF, there was no statistical difference in all-cause mortality or HF events with ablation-based rhythm-control versus rate-control, however, there was a non-significant trend for improved outcomes with ablation-based rhythm control over rate-control.
Collapse
|
21
|
A Cost-Utility Analysis of the Syncope: Pacing or Recording In ThE Later Years Trial. CJC Open 2022; 4:617-624. [PMID: 35865020 PMCID: PMC9294989 DOI: 10.1016/j.cjco.2022.03.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2022] [Accepted: 03/25/2022] [Indexed: 12/05/2022] Open
Abstract
Background The Syncope: Pacing or Recording in the Later Years (SPRITELY) trial reported that a strategy of empiric permanent pacing in patients with syncope and bifascicular block reduces major adverse events more effectively than acting on the results of an implantable cardiac monitor (ICM). Our objective was to determine the cost-effectiveness of using the ICM, compared with a pacemaker (PM), in the management of older adults (age > 50 years) with bifascicular block and syncope enrolled in the SPRITELY trial. Methods SPRITELY was a pragmatic, open-label randomized controlled trial with a median follow-up of 33 months. The primary outcome of this analysis is the cost per additional quality-adjusted life-year (QALY). Resource utilization and utility data were collected prospectively, and outcomes at 2 years were compared between the 2 arms. A decision analytic model simulated a 3-year time horizon. Results The mean cost incurred by participants randomized to the PM arm was $9918, compared to $15,416 (both in Canadian dollars) for participants randomized to the ICM arm. The ICM strategy resulted in 0.167 QALYs fewer than the PM strategy. Cost and QALY outcomes are sensitive to the proportion of participants randomized to the ICM arm who subsequently required PM insertion. In 40,000 iterations of probabilistic sensitivity analysis, the PM strategy resulted in cost-savings in 99.7% of iterations, compared with the ICM strategy. Conclusions The PM strategy was dominant—that is, less costly and estimated to result in a greater number of QALYs. For patients with unexplained syncope, bifascicular block, and age > 50 years, a PM is more likely to be cost-effective than an ICM.
Collapse
|
22
|
Pattern of Atrial Fibrillation and Cognitive Function in Young Patients With Atrial Fibrillation and Low CHADS 2 Score: Insights From the BRAIN-AF Trial. Circ Arrhythm Electrophysiol 2022; 15:e010462. [PMID: 35089051 DOI: 10.1161/circep.121.010462] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
23
|
Randomized Pragmatic Trial of Pacemaker Versus Implantable Cardiac Monitor in Syncope and Bifascicular Block. JACC Clin Electrophysiol 2022; 8:239-248. [PMID: 35210082 DOI: 10.1016/j.jacep.2021.10.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2021] [Revised: 10/01/2021] [Accepted: 10/08/2021] [Indexed: 10/19/2022]
Abstract
OBJECTIVES In this study, the authors tested whether a strategy of empiric permanent pacing reduces major composite events more effectively than acting on the results of an implantable cardiac monitor (ICM). BACKGROUND Syncope may be caused by intermittent complete heart block in patients with bifascicular heart block, but competing diagnoses coexist. Whether empiric permanent pacing or acting on investigative results provides best care is unknown. METHODS This was a multinational, randomized, pragmatic clinical trial of patients ≥50 years of age with bifascicular block, preserved left ventricular function, and ≥1 syncope in the preceding year. The primary composite outcome measure comprised cardiovascular death, syncope, bradycardia resulting in pacemaker insertion, and device complications. RESULTS There were 57 and 58 subjects randomized to receive a pacemaker or ICM. A total of 41 patients had left bundle branch block and 74 had right bundle branch block and a left fascicular block. Patients were followed for a median 33 months. There were fewer composite primary outcomes in patients randomized to pacemaker compared with ICM, respectively (20 [35%] vs 44 [76%]; chi square P < 0.0001), with lower actuarial probabilities of a primary outcome (0.45 and 1.00; P < 0.001). Syncope was as likely in the groups randomized to receive a pacemaker or ICM (29% vs 26%, chi-square P = 0.95). CONCLUSIONS Empiric permanent pacing compared with ICM reduced major adverse events but not syncope in older patients with bifascicular block and recent syncope. There remains a substantial likelihood of syncope recurrence in patients who receive a permanent pacemaker likely caused by vasodepressor syncope. (Syncope: Pacing or Recording in the Later Years [SPRITELY]; NCT01423994).
Collapse
|
24
|
Ventricular tachycardia characteristics and outcomes with catheter ablation vs. antiarrhythmic therapy: insights from the VANISH trial. Europace 2022; 24:1112-1118. [PMID: 35030257 PMCID: PMC9301970 DOI: 10.1093/europace/euab328] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2021] [Accepted: 12/22/2021] [Indexed: 01/16/2023] Open
Abstract
AIMS Catheter ablation is superior to escalated antiarrhythmic drugs among patients with ventricular tachycardia (VT) and prior myocardial infarction (MI). However, it is uncertain whether clinical VT characteristics, should influence choice of therapy. The purpose of this study was to evaluate whether presentation with electrical storm and the clinical VT cycle length predicted response to ablation vs. escalated antiarrhythmic therapy. METHODS AND RESULTS All patients enrolled in the Ventricular Tachycardia Ablation vs. Escalated Antiarrhythmic Drug Therapy in Ischaemic Heart Disease (VANISH) trial were included. The association between VT cycle length and presentation with electrical storm and the primary outcome of death, subsequent VT storm or appropriate ICD shock was evaluated. Among the study population of 259 patients, escalated antiarrhythmic drug therapy had worse outcomes for those presenting with a VT cycle length >400 ms [<150 b.p.m., 89/259, hazard ratio (HR) 1.7 (1.02-3.13)]. This effect was more pronounced among those taking amiodarone at baseline [HR of 2.22 (1.19-4.16)]. Presentation with VT storm (32/259) did not affect the primary outcome between groups. However, those presenting with VT storm on amiodarone had a trend towards worse outcomes with escalated antiarrhythmic therapy [HR 4.31 (0.55-33.93)]. CONCLUSION The VT cycle length can influence response to either ablation or escalated drug therapy in patients with VT and prior MI. Those with slow VT had improved outcomes with ablation. Patients presenting with electrical storm demonstrated similar outcomes to the overall trial population, with a trend to benefit of catheter ablation, particularly in those on amiodarone.
Collapse
|
25
|
Randomized trial of conventional versus radiofrequency needle transseptal puncture for cryoballoon ablation: the CRYO-LATS trial. J Interv Card Electrophysiol 2022; 65:481-489. [PMID: 35739438 PMCID: PMC9640463 DOI: 10.1007/s10840-022-01277-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2022] [Accepted: 06/09/2022] [Indexed: 12/30/2022]
Abstract
BACKGROUND Transseptal puncture to achieve left atrial access is necessary for many cardiac procedures, including atrial fibrillation ablation. More recently, there has been an increasing need for left atrial access using large caliber sheaths, which increases risk of perforation associated with the initial advancement into the left atrium. We compared the effectiveness of a radiofrequency needle-based transseptal system versus conventional needle for transseptal access. METHODS This prospective controlled trial randomized 161 patients with symptomatic paroxysmal atrial fibrillation undergoing cryoballoon pulmonary vein isolation to transseptal access with a commercially available transseptal system (radiofrequency needle plus stiff pigtail wire; RF + Pigtail group) versus conventional transseptal access (standard group). The primary outcome was time required for left atrial access. Secondary outcomes included failure of the assigned transseptal system, radiation exposure, and complications. RESULTS The median transseptal puncture time was significantly shorter using the radiofrequency needle plus stiff pigtail wire transseptal system compared with conventional transseptal (840 ± 323 vs. 956 ± 407 s, P = 0.0489). Compared to conventional transseptal puncture, fewer transseptal attempts were required (1.0 ± 0.5 RF applications vs. 1.3 ± 0.8 mechanical punctures, P = 0.0123) and the fluoroscopy time was significantly shorter (72.0 [IQR 48.0, 129.0] vs. 93.0 [IQR 60.0, 171.0] s, P = 0.0490) with the radiofrequency needle plus stiff pigtail wire transseptal system. Failure to achieve transseptal LA access with the assigned system was rarely observed (1.3% vs. 5.7%, P = 0.2192). There were no procedural complications observed with either system. CONCLUSIONS The use of a radiofrequency needle plus stiff pigtail wire resulted in shorter time to left atrial access and reduced fluoroscopy time compared to left atrial access using conventional transseptal equipment. TRIAL REGISTRATION ClinicalTrials.gov identifier NCT03199703.
Collapse
|
26
|
Comparative effectiveness of ventricular tachycardia ablation vs. escalated antiarrhythmic drug therapy by location of myocardial infarction: a sub-study of the VANISH trial. Europace 2021; 24:948-958. [PMID: 34964475 PMCID: PMC9282915 DOI: 10.1093/europace/euab298] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Accepted: 11/16/2021] [Indexed: 12/31/2022] Open
Abstract
AIMS Complexity of the ventricular tachycardia (VT) substrate and the size and thickness of infarction area border zones differ based on location of myocardial infarctions (MIs). These differences may translate into heterogeneity in the effectiveness of treatments. This study aims to examine the influence of infarct location on the effectiveness of VT ablation in comparison with escalated pharmacological therapy in patients with prior MI and antiarrhythmic drug (AAD)-refractory VT. METHODS AND RESULTS VANISH trial participants were categorized based on the presence or absence of an inferior MI scar. Inverse probability of treatment weighted Cox models were calculated for each subgroup. Of 259 randomized patients (median age 69.8 years, 7.0% women), 135 had an inferior MI and 124 had a non-inferior MI. Among patients with an inferior MI, no statistically significant difference in the composite primary outcome of all-cause mortality, appropriate implantable cardioverter-defibrillator (ICD) shock, and VT storm was detected between treatment arms [adjusted hazard ratio (aHR) 0.80, 95% confidence interval (CI) 0.51-1.20]. In contrast, patients with non-inferior MIs had a statistically significant reduction in the incidence of the primary outcome with ablation (aHR 0.48, 95% CI 0.27-0.86). In a sensitivity analysis of anterior MI patients (n = 83), a trend towards a reduction in the primary outcome with ablation was detected (aHR 0.50, 95% CI 0.23-1.09). CONCLUSION The effectiveness of VT ablation versus escalated AADs varies based on the location of the MI. Patients with MI scars located only in non-inferior regions of the ventricles derive greater benefit from VT ablation in comparison to escalation of AADs in reducing VT-related events.
Collapse
|
27
|
Impact of Choice of Prophylaxis on the Microbiology of Cardiac Implantable Electronic Device Infections: Insights From the Prevention of Arrhythmia Device Infection Trial (PADIT). Open Forum Infect Dis 2021; 8:ofab513. [PMID: 34859113 PMCID: PMC8632784 DOI: 10.1093/ofid/ofab513] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Accepted: 10/12/2021] [Indexed: 01/01/2023] Open
Abstract
Background The Prevention of Arrhythmia Device Infection Trial (PADIT) investigated whether intensification of perioperative prophylaxis could prevent cardiac implantable electronic device (CIED) infections. Compared with a single dose of cefazolin, the perioperative administration of cefazolin, vancomycin, bacitracin, and cephalexin did not significantly decrease the risk of infection. Our objective was to compare the microbiology of infections between study arms in PADIT. Methods This was a post hoc analysis. Differences between study arms in the microbiology of infections were assessed at the level of individual patients and at the level of microorganisms using the Fisher exact test. Results Overall, 209 microorganisms were reported from 177 patients. The most common microorganisms were coagulase-negative staphylococci (CoNS; 82/209 [39.2%]) and S. aureus (75/209 [35.9%]). There was a significantly lower proportion of CoNS in the incremental arm compared with the standard arm (30.1% vs 46.6%; P = .04). However, there was no significant difference between study arms in the frequency of recovery of other microorganisms. In terms of antimicrobial susceptibility, 26.5% of microorganisms were resistant to cefazolin. CoNS were more likely to be cefazolin-resistant in the incremental arm (52.2% vs 26.8%, respectively; P = .05). However, there was no difference between study arms in terms of infections in which the main pathogen was sensitive to cefazolin (77.8% vs 64.3%; P = .10) or vancomycin (90.8% vs 90.2%; P = .90). Conclusions Intensification of the prophylaxis led to significant changes in the microbiology of infections, despite the absence of a decrease in the overall risk of infections. These findings provide important insight on the physiopathology of CIED infections. Trial registration NCT01002911.
Collapse
|
28
|
Post-operative pain following cardiac implantable electronic device implantation: insights from the BRUISE CONTROL trials. Europace 2021; 23:748-756. [PMID: 33367623 DOI: 10.1093/europace/euaa349] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2020] [Accepted: 11/12/2020] [Indexed: 01/15/2023] Open
Abstract
AIMS Post-operative pain following cardiac implantable electronic device (CIED) insertion is associated with patient dissatisfaction, emotional distress, and emergency department visits. We sought to identify factors associated with post-operative pain and develop a prediction score for post-operative pain. METHODS AND RESULTS All patients from the BRUISE CONTROL-1 and 2 trials were included in this analysis. A validated Visual Analogue Scale (VAS) was used to assess the severity of pain related to CIED implant procedures. Patients were asked to grade the most severe post-operative pain, average post-operative pain, and pain on the day of the first post-operative clinic. Multivariable regression analyses were performed to identify predictors of significant post-operative pain and to develop a pain-prediction score. A total of 1308 patients were included. Multivariable regression analysis found that the presence of post-operative clinically significant haematoma {CSH; P value < 0.001; odds ratio (OR) 3.82 [95% confidence interval (CI): 2.37-6.16]}, de novo CIED implantation [P value < 0.001; OR 1.90 (95% CI: 1.47-2.46)], female sex [P value < 0.001; OR 1.61 (95% CI: 1.22-2.12)], younger age [<65 years; P value < 0.001; OR 1.54 (95% CI: 1.14-2.10)], and lower body mass index [<20 kg/m2; P value < 0.05; OR 2.05 (95% CI: 0.98-4.28)] demonstrated strong and independent associations with increased post-operative pain. An 11-point post-operative pain prediction score was developed using the data. CONCLUSION Our study has identified multiple predictors of post-operative pain after CIED insertion. We have developed a prediction score for post-operative pain that can be used to identify individuals at risk of experiencing significant post-operative pain.
Collapse
|
29
|
Long-term effectiveness of catheter ablation in patients with atrial fibrillation and heart failure. Europace 2021; 22:739-747. [PMID: 32227165 DOI: 10.1093/europace/euaa036] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2019] [Accepted: 02/11/2020] [Indexed: 01/20/2023] Open
Abstract
AIMS Randomized trials suggest reductions in all-cause mortality and heart failure (HF) rehospitalizations with catheter ablation (CA) in patients with atrial fibrillation (AF) and HF. Whether these results can be replicated in a real-world population with long-term follow-up or varies over time is unknown. We sought to evaluate the long-term effectiveness of CA in reducing the incidence of all-cause mortality, HF hospitalizations, stroke, and major bleeding in AF-HF patients. METHODS AND RESULTS In a cohort of patients newly diagnosed with AF-HF in Quebec, Canada (2000-2017), CA patients were matched 1:2 to controls on time and frequency of hospitalizations. Confounders were controlled for using inverse probability of treatment weighting. Multivariable Cox models adjusted for the presence of cardiac electronic implantable devices and medication use during follow-up, and the effect of time since CA was modelled with B-splines. For non-fatal outcomes, the Lunn-McNeil approach was used to account for the competing risk of death. Among 101 933 AF-HF patients, 451 underwent CA and were matched to 899 controls. Over a median follow-up of 3.8 years, CA was associated with a statistically significant reduction in all-cause mortality [hazard ratio 0.4 (95% confidence interval 0.2-0.7)], but no difference in stroke or major bleeding. The hazard of HF rehospitalization for CA patients, relative to non-CA patients, varied with time since CA (P = 0.01), with a reduction in HF rehospitalizations until approximately 3 years post-CA. CONCLUSION Compared with matched non-CA patients, CA was associated with a long-term reduction in all-cause mortality and a reduction in HF rehospitalizations until 3 years post-CA.
Collapse
|
30
|
Relationship between quality of life and burden of recurrent atrial fibrillation following ablation: CAPCOST multicentre cohort study. Europace 2021; 22:1017-1025. [PMID: 32531030 DOI: 10.1093/europace/euaa066] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2019] [Accepted: 03/13/2020] [Indexed: 01/12/2023] Open
Abstract
AIMS Atrial fibrillation (AF) significantly impairs patients' quality of life (QOL). We performed this study to investigate the effect of AF-ablation success and atrial fibrillation burden (AFB) on QOL measures. METHODS AND RESULTS Overall, 230 patients with paroxysmal AF refractory to antiarrhythmic drugs were enrolled and underwent ablation in a multicentre, prospective cohort. Electrocardiogram, 48-h Holter, Canadian Cardiovascular Society Severity of Atrial Fibrillation (CCS-SAF), short form-12 (SF-12), and Atrial Fibrillation Effect on Quality of life (AFEQT) scales were used to assess patients. Atrial fibrillation burden was defined as total duration of AF during the month prior to each visit (h/month). The change in AFB was calculated as the difference between the month prior to the 12-month post-ablation and the baseline pre-ablation. The Minimal Clinically Important Difference (MCID) was considered as a 19-point change for AFEQT and 3-5-point change for SF-12 scores. There was significant rise in the AFEQT and SF12 and decrease in CCS-SAF score post-AF ablation; however, the magnitude of these changes was greater in patients without AF recurrence (P < 0.05). The QOL score that best differentiated patients with and without recurrence was AFEQT, while, CCS-SAF was the most specific score. Patients with AFB decrease >19 h/month had significantly greater change in QOL scores. Atrial fibrillation burden < 24 h/month at 12-months post-ablation was associated with significant changes in QOL and CCS-SAF when adjusting for baseline scores and other covariates. These changes were consistent with the MCID of these measures. CONCLUSION Patients experience significant improvements in QOL post-ablation, which correlate with a decrease in AFB despite ongoing brief recurrences of AF. CLINICAL TRIAL REGISTRATION NCT01562912. https://www.clinicaltrials.gov/ct2/show/NCT01562912? term=capcost&rank=1.
Collapse
|
31
|
Comparative effectiveness of ventricular tachycardia ablation versus escalated antiarrhythmic drug therapy by location of myocardial infarction: A sub-study of the VANISH trial. Europace 2021. [DOI: 10.1093/europace/euab116.073] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Abstract
Funding Acknowledgements
Type of funding sources: Public Institution(s). Main funding source(s): Fonds de recherché du Québec-Santé (FRQS) [post doctoral award for Dr. Samuel)
BACKGROUND
Complexity of ventricular tachycardia (VT) substrate, efficiency of lesion formation, and the size and thickness of infarction area border zones differ based on location of myocardial infarctions (MI). These differences may translate into heterogeneity in risk of events and effectiveness of treatments for VT. Small observational studies suggest that VT from inferior infarctions have higher risk of early recurrence despite smaller infarct areas. However, differential effectiveness of VT treatments based on location of MI not been definitively established.
PURPOSE
The objective of this sub-study of the Ventricular tachycardia AblatioN versus escalated antiarrhythmic drug therapy in ISchemic Heart disease (VANISH) randomized trial was to compare the effectiveness of VT ablation by location of MI in reducing the composite endpoint of all-cause mortality, VT storm, or appropriate ICD therapy when compared to escalated pharmacological therapy in VT patients with a prior MI.
METHODS
VANISH participants were categorized into 3 subgroups based on MI location: 1. Inferior (may also have MI in other locations); 2. Non-inferior (no inferior MI, all patients not in group 1); and 3. Anterior (may also have MI in other locations). Inverse probability of treatment weighting was used to balance baseline characteristics (ie. age, sex, comorbidities, medications, and the location of additional infarctions) between patients randomized to ablation or escalated therapy within each subgroup. Weighted Cox proportional hazards models were calculated separately for each subgroup.
RESULTS
Of 259 patients enrolled in the VANISH trial [median age 69.8 (IQR 63.0-74.2) years, 7.0% women], 135 had an inferior MI, 124 a non-inferior MI, and 83 an anterior MI. Among patients with an inferior MI, no statistically significant difference in the primary outcome was detected between patients randomized to ablation or escalated therapy [aHR 0.78 (95% CI 0.51-1.20)]. In contrast, patients with non-inferior MIs had a statistically significant reduction in the incidence of the primary outcome with ablation [aHR 0.48 (95% CI 0.27-0.86)]; which was of greater magnitude than the reduction observed in the overall results of the VANISH trial [HR 0.72 (95% CI 0.53-0.98)]. In addition, a trend towards a reduction in the primary outcome with ablation was detected in patients with anterior MIs [aHR 0.50 (95% CI 0.23-1.09)].
CONCLUSION
The effectiveness of VT ablation versus escalated pharmacological therapy varies based on the location of the MI. Patients with MI scars located only in non-inferior regions of the ventricles derive greater benefit from VT ablation in reducing VT-related events. Further studies are required to explore reasons for this finding and to assess the impact of VT treatment strategies based on MI location in optimizing outcomes.
Collapse
|
32
|
A randomized ablation-based atrial fibrillation rhythm control versus rate control trial in patients with heart failure and high burden atrial fibrillation: The RAFT-AF trial rationale and design. Am Heart J 2021; 234:90-100. [PMID: 33472052 DOI: 10.1016/j.ahj.2021.01.012] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/15/2020] [Accepted: 01/15/2021] [Indexed: 10/22/2022]
Abstract
Heart failure (HF) and atrial fibrillation (AF) are 2 cardiac conditions that are increasing in prevalence and incidence. The 2 conditions frequently coexist, and are associated with increased morbidity and mortality. Catheter ablation of AF has been successfully performed in patients with HF, with an improvement in HF and AF, when compared to amiodarone, but further data is required to compare this to rate control. OBJECTIVES: The primary objective is to determine whether AF treated by catheter ablation, with or without antiarrhythmic drugs reduces all-cause mortality and hospitalizations for HF as compared with rate control in patients with HF and a high burden AF. METHODS: This is a multi-center prospective randomized open blinded endpoint (PROBE) study. Patients with NYHA class II-III HF (HF with reduced ejection fraction (<35%) or HF with preserved ejection fraction), and high burden AF are included in the trial. Patients are randomized to either rate control or catheter ablation-based AF rhythm control in a 1:1 ratio. Patients in the rate control group receive optimal HF therapy and rate control measures to achieve a resting hazard ratio (HR) < 80 bpm and 6-minute walk HR < 110 bpm. Patients randomized to catheter ablation-based AF rhythm control group receive optimal HF therapy and one or more aggressive catheter ablation, which include PV antral ablation and LA substrate ablation with or without adjunctive antiarrhythmic drug. The primary outcome is a composite of all-cause mortality and hospitalization for heart failure defined as an admission to a health care facility. The sample size is 600. Enrolment has been completed.
Collapse
|
33
|
Canadian Registry of Electronic Device Outcomes: remote monitoring outcomes in the Abbott battery performance alert-a multicentre cohort. Europace 2021; 23:1319-1323. [PMID: 33608700 DOI: 10.1093/europace/euab025] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2020] [Accepted: 01/19/2021] [Indexed: 11/12/2022] Open
Abstract
AIMS Cardiac implantable electronic devices with device advisories have the potential of device malfunction. Remote monitoring (RM) of devices has been suggested to allow the identification of abnormal device performance and permit early intervention. We sought to describe the outcomes of patients with and without RM in devices subject to the Abbott Premature Battery Depletion (PBD) advisory with data from a Canadian registry. METHODS AND RESULTS Patients with an Abbott device subject to the PBD advisory from nine implantable cardioverter defibrillator (ICD) implanting centres in Canada were included in the registry. The use of RM was identified from baseline and follow-up data in the registry. The primary outcome was detection of PBD and all-cause mortality. A total of 2666 patients were identified with a device subject to the advisory. In all, 1687 patients (63.2%) had RM at baseline. There were 487 deaths during follow-up. At a mean follow-up of 5.7 ± 0.7 years, mortality was higher in those without a remote monitor compared with RM at baseline (24.7% vs. 14.5%; P < 0.001). Pre-mature battery depletion was identified in 36 patients (2.1%) with RM vs. 7 (0.7%) without RM (P = 0.004). Time to battery replacement was significantly reduced in patients on RM (median 5 vs. 13 days, P = 0.001). CONCLUSION The use of RM in patients with ICD and cardiac resynchronization therapy under advisory improved detection of PBD, time to device replacement, and was associated with a reduction in all-cause mortality. The factors influencing the association with mortality are unknown and deserve further study.
Collapse
|
34
|
Abstract
BACKGROUND Guidelines recommend a trial of one or more antiarrhythmic drugs before catheter ablation is considered in patients with atrial fibrillation. However, first-line ablation may be more effective in maintaining sinus rhythm. METHODS We randomly assigned 303 patients with symptomatic, paroxysmal, untreated atrial fibrillation to undergo catheter ablation with a cryothermy balloon or to receive antiarrhythmic drug therapy for initial rhythm control. All the patients received an implantable cardiac monitoring device to detect atrial tachyarrhythmia. The follow-up period was 12 months. The primary end point was the first documented recurrence of any atrial tachyarrhythmia (atrial fibrillation, atrial flutter, or atrial tachycardia) between 91 and 365 days after catheter ablation or the initiation of an antiarrhythmic drug. The secondary end points included freedom from symptomatic arrhythmia, the atrial fibrillation burden, and quality of life. RESULTS At 1 year, a recurrence of atrial tachyarrhythmia had occurred in 66 of 154 patients (42.9%) assigned to undergo ablation and in 101 of 149 patients (67.8%) assigned to receive antiarrhythmic drugs (hazard ratio, 0.48; 95% confidence interval [CI], 0.35 to 0.66; P<0.001). Symptomatic atrial tachyarrhythmia had recurred in 11.0% of the patients who underwent ablation and in 26.2% of those who received antiarrhythmic drugs (hazard ratio, 0.39; 95% CI, 0.22 to 0.68). The median percentage of time in atrial fibrillation was 0% (interquartile range, 0 to 0.08) with ablation and 0.13% (interquartile range, 0 to 1.60) with antiarrhythmic drugs. Serious adverse events occurred in 5 patients (3.2%) who underwent ablation and in 6 patients (4.0%) who received antiarrhythmic drugs. CONCLUSIONS Among patients receiving initial treatment for symptomatic, paroxysmal atrial fibrillation, there was a significantly lower rate of atrial fibrillation recurrence with catheter cryoballoon ablation than with antiarrhythmic drug therapy, as assessed by continuous cardiac rhythm monitoring. (Funded by the Cardiac Arrhythmia Network of Canada and others; EARLY-AF ClinicalTrials.gov number, NCT02825979.).
Collapse
|
35
|
Canadian Registry of Electronic Device Outcomes (CREDO): The Abbott ICD Premature Battery Depletion Advisory, a Multicentre Cohort Study. CJC Open 2021; 3:48-53. [PMID: 33458632 PMCID: PMC7801196 DOI: 10.1016/j.cjco.2020.09.008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2020] [Accepted: 09/08/2020] [Indexed: 11/30/2022] Open
Abstract
Background Premature or rapid battery depletion may compromise the performance and reliability of an implantable cardioverter defibrillator (ICD), potentially resulting in harm or death to patients. We sought to describe the outcomes and clinical management of devices included in the Abbott ICD Premature Battery Depletion Advisory, using data from a Canadian registry. Methods This prospective observational study includes patients with an Abbott device subject to the advisory, from 9 centres in Canada. The incidence and outcomes related to device revision owing to premature battery depletion were identified and adjudicated by a committee. Results There were 2678 patients enrolled with a device subject to the advisory. Devices were implanted between 2010 and 2017; follow-up time was 5.7 ± 0.7 years. Device revision occurred in 222 patients (8.3%). Revision for premature battery depletion occurred in 43 patients (1.6%). Devices were revised at physician discretion on notice of the advisory in 16 patients (0.6%), and at patient request in 5 patients (0.2%). A total of 63 (2.4%) devices reached routine end of battery life. A further 95 (3.5%) patients underwent revision for other reasons. There were no reported major complications or adverse events with device revision owing to the advisory. There were no deaths attributed to premature battery depletion. Conclusions The rate of premature battery depletion associated with the Abbott ICD Premature Battery Depletion Advisory is low. There were no clinically adverse events identified that were associated with the battery performance of devices under advisory.
Collapse
|
36
|
Fusion pacing in patients with right bundle branch block who undergo cardiac resynchronization therapy. J Electrocardiol 2020; 64:66-71. [PMID: 33348136 DOI: 10.1016/j.jelectrocard.2020.12.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2020] [Revised: 11/26/2020] [Accepted: 12/02/2020] [Indexed: 11/30/2022]
Abstract
PURPOSE Patients with right bundle branch block (RBBB) are less likely to respond to cardiac resynchronization therapy (CRT). We aimed to assess whether patients with RBBB respond to CRT with biventricular fusion pacing. METHODS Consecutive patients with RBBB at a single tertiary care center, who were implanted with a CRT device capable of biventricular fusion pacing using SyncAV programming, were assessed and compared to a historical cohort of CRT patients with RBBB. QRSd was measured and compared during intrinsic conduction, nominal CRT pacing and manual electrocardiogram-based optimized SyncAV programming. Left ventricular ejection fraction (LVEF) was also compared before and 6 months after CRT. RESULTS We included 8 consecutive patients with RBBB (group 1) who were able to undergo SyncAV programming and 16 patients with RBBB (group 2) from a historical cohort. In group 1, compared to mean intrinsic conduction QRSd (155 ± 13 ms), mean nominally-paced QRSd was 156 ± 15 ms (ΔQRSd 1.3 ± 11.6; p = 0.77) and SyncAV-optimized paced QRSd was 135 ± 14 ms (ΔQRSd -20.0 ± 20.4; p = 0.03 and ΔQRSd -21.3 ± 16.3; p = 0.008; compared to intrinsic conduction and nominal pacing respectively). In group 2, mean QRSd with nominal pacing was 160 ± 24 ms (ΔQRSd 3.8 ± 33.4; p = 0.66 compared to intrinsic conduction). In group 1, baseline LVEF was 22.1 ± 11.5 and after 6 months of follow-up was 27.8 ± 8.6 (p = 0.047). In group 2, the baseline LVEF was 27.2 ± 10.6 and after 6 months of follow-up was 25.0 ± 10.0 (p = 0.45). CONCLUSIONS CRT programed to allow biventricular fusion pacing significantly improved electrical synchrony and LVEF in patients with RBBB. Larger studies are required to confirm these findings.
Collapse
|
37
|
Association of the left common ostium with clinical outcome after pulmonary vein isolation in atrial fibrillation. Indian Pacing Electrophysiol J 2020; 21:95-100. [PMID: 33271275 PMCID: PMC7952770 DOI: 10.1016/j.ipej.2020.11.020] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2020] [Revised: 11/01/2020] [Accepted: 11/27/2020] [Indexed: 11/19/2022] Open
Abstract
Introduction Electrical pulmonary vein isolation (PVI) is used for the invasive treatment of atrial fibrillation (AF). However, despite the procedure’s technical evolution, the rate of AF recurrence due to electrical reconnection of the PVs is high. The aims of this study was to assess the influence of left common pulmonary venous ostium (LCO) on clinical outcomes following PVI. Methods Retrospective cohort of 254 patients who underwent the first procedure of PVI from the years 2013–2018 was assessed. Patients with persistent AF of long duration and extra-pulmonary focus associated with triggers for arrhythmia were excluded. Patients were stratified into two groups according to the presence of a LCO and received follow up for atrial tachyarrhythmia-free survival. The mean follow-up period was 28 ± 1.73 months. Results The majority were men (68.5%), with a mean age of 54 ± 12 years. With respect to the atrial anatomy, LCO occurred in 23.6% of cases after pulmonary venous angiotomography. The arrhythmia-free survival rate was 79.5% in the follow-up period. The Cox regression model was utilized and the adjusted hazard ratio for LCO was 0.36 (95% CI 0.15–0.87; p = 0.02) in terms of age, body mass index, left atrium diameter, bi-directional blocking of the cavotricuspid isthmus, persistent AF, left ventricular ejection fraction adjusted model. Conclusion Anatomic abnormality with the presence of the LCO is present in a quarter of patients undergoing AF ablation, which is associated with a lower rate of arrhythmia recurrence in our population. Pulmonary vein isolation is used for the invasive treatment of atrial fibrillation. The majority of arrhythmias triggers have their origins in the anatomic abnormality. Pulmonary vein isolation using radiofrequency ablation.
Collapse
|
38
|
Class I and Class III Antiarrhythmic Agents: Mechanisms of Action and the Problem of Proarrhythmic Activity. Mcgill J Med 2020. [DOI: 10.26443/mjm.v1i2.723] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
|
39
|
Catheter Ablation of Atrial Fibrillation: Current and Evolving Indications. Can J Cardiol 2020; 36:1685-1689. [DOI: 10.1016/j.cjca.2020.01.012] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2019] [Revised: 01/04/2020] [Accepted: 01/07/2020] [Indexed: 11/16/2022] Open
|
40
|
2020 Canadian Cardiovascular Society/Canadian Heart Rhythm Society Position Statement on the Management of Ventricular Tachycardia and Fibrillation in Patients With Structural Heart Disease. Can J Cardiol 2020; 36:822-836. [DOI: 10.1016/j.cjca.2020.04.004] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2020] [Revised: 03/29/2020] [Accepted: 04/05/2020] [Indexed: 10/24/2022] Open
|
41
|
Population-Level Sex Differences and Predictors for Treatment With Catheter Ablation in Patients With Atrial Fibrillation and Heart Failure. CJC Open 2020; 2:85-93. [PMID: 32462121 PMCID: PMC7242511 DOI: 10.1016/j.cjco.2020.01.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2019] [Accepted: 01/20/2020] [Indexed: 10/26/2022] Open
Abstract
Background Current guidelines are relatively general regarding the type of patient with heart failure (HF) who should be considered for catheter ablation (CA) of atrial fibrillation (AF). The aim of the present study was to identify clinical predictors and sex differences for treatment with CA in the AF-HF population. Methods A population-based AF-HF cohort was created using the Quebec administrative data (2000-2017). Patients were followed from the date of diagnosis of both diseases to the date of CA or death. Predictors for CA, represented by time-varying covariates, were assessed in a multivariable Cox model that accounted for the competing risk of death. Results Among 101,931 patients with AF-HF with medication information (median age, 80.7 years; interquartile range [IQR], 73.9-86.3; 51.4% were female, median CHA2DS2-VASc, 4; IQR, 3-4), only 432 (0.4%) underwent CA after a median of 0.8 years (IQR, 0.1-2.7). Independent of multiple comorbidities and advanced age, which were associated with a lower likelihood of CA, women were approximately half as likely to undergo a CA (26% were women; adjusted hazard ratio, 0.6; 95% confidence interval, 0.4-0.7). Prior use of direct-acting oral anticoagulants and antiarrhythmics, and the presence of an implantable cardioverter-defibrillator were also predictors for CA treatment (P < 0.05 for all). Conclusion In a real-world population, CA was infrequently used to treat AF among patients with HF, and the likelihood of CA was further reduced in women. Because patients with CA had few comorbidities, future studies need to be conducted to determine whether CA can be beneficial in subjects whose clinical characteristics are more representative of the AF-HF population.
Collapse
|
42
|
Long-term outcomes of catheter ablation for atrial fibrillation: It's a matter of time. J Cardiovasc Electrophysiol 2020; 31:1048-1050. [PMID: 32115788 DOI: 10.1111/jce.14428] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2020] [Accepted: 02/24/2020] [Indexed: 11/28/2022]
|
43
|
Sustained quality-of-life improvement post-cryoballoon ablation in patients with paroxysmal atrial fibrillation: Results from the STOP-AF Post-Approval Study. Heart Rhythm 2020; 17:485-491. [DOI: 10.1016/j.hrthm.2019.10.014] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/03/2019] [Indexed: 10/25/2022]
|
44
|
Mortality Risk Increases With Clustered Ventricular Arrhythmias in Patients With Implantable Cardioverter-Defibrillators. JACC Clin Electrophysiol 2020; 6:327-337. [PMID: 32192684 DOI: 10.1016/j.jacep.2019.11.012] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2019] [Revised: 11/12/2019] [Accepted: 11/14/2019] [Indexed: 11/25/2022]
Abstract
OBJECTIVES This study sought to examine the adverse prognosis associated with ventricular arrhythmia clusters that falls outside the current electrical storm definition. BACKGROUND Electrical storm is most frequently defined as a cluster of ≥3 episodes of ventricular arrhythmia (VA) in a 24-h period. This definition has been associated with adverse cardiovascular outcomes and mortality, but the effect of lesser and greater clustering of arrhythmias has not been described. METHODS Among all patients in the Resynchronization in Ambulatory Heart Failure trial, 14,515 implantable cardioverter-defibrillator-detected events with data available were rigorously adjudicated in blinded fashion. Arrhythmia incidence was examined for clustering, defined as 2 or more VA events occurring within 3 months. The prognostic importance of clustering was analyzed by varying the cluster length and number of events used to define a cluster. Mortality rates of groups with clustered arrhythmias were compared to patients with no arrhythmia or with unclustered arrhythmia. RESULTS The trial included 1,764 patients, among whom 465 patients had two or more VA episodes within 3 months, whereas 406 had unclustered arrhythmias. Compared to patients with no arrhythmia, patients experiencing unclustered VA had increased risk of death (hazard ratio [HR]: 1.45; 95% confidence interval [CI]: 1.09 to 1.93; p = 0.011), whereas the risk was even higher in patients with clustered arrhythmia (HR: 2.68; 95% CI: 2.13 to 3.36; p < 0.0001). Mortality risk increased with higher VA burden (number of VAs in a cluster) and shorter cluster length. This was observed in all groups tested, including the cluster with the least VA burden in the longest cluster length tested (2 VA episodes occurring within 3 months) (mortality HR: 2.85; 95% CI: 1.95 to 4.17; p < 0.0001). Although clustered arrhythmias terminated with antitachycardia pacing were associated with increased mortality, clusters terminated with implantable cardioverter-defibrillator shocks were associated with still higher mortality risk. CONCLUSIONS Significant adverse prognostic association of clustered VAs is observable with even 2 VA events within 3 months and increases with higher cluster density.
Collapse
|
45
|
Optimization of Chronic Cardiac Resynchronization Therapy Using Fusion Pacing Algorithm Improves Echocardiographic Response. CJC Open 2020; 2:62-70. [PMID: 32190827 PMCID: PMC7067690 DOI: 10.1016/j.cjco.2019.12.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2019] [Accepted: 12/22/2019] [Indexed: 11/15/2022] Open
Abstract
Background Whether reprogramming of cardiac resynchronization therapy (CRT) to increase electrical synchrony translates into echocardiographic improvement remains unclear. SyncAV is an algorithm that allows fusion of intrinsic conduction with biventricular pacing. We aimed to assess whether reprogramming chronically implanted CRT devices with SyncAV is associated with improved echocardiographic parameters. Methods Patients at a quaternary center with previously implanted CRT devices with a programmable SyncAV algorithm underwent routine electrocardiography-based SyncAV optimization during regular device clinic visits. This analysis included only patients who could be programmed to the SyncAV algorithm (i.e., in sinus rhythm with intrinsic atrioventricular conduction). Echocardiography was performed before and 6 months after CRT optimization. Results Of 64 consecutive, potentially eligible patients who underwent assessment, 34 who were able to undergo SyncAV programming were included. Their mean age was 74 ± 9 years, 41% were female, and 59% had ischemic cardiomyopathy. The mean time from CRT implant to SyncAV optimization was 17.8 ± 8.5 months. At 6-month follow-up, SyncAV optimization was associated with a significant increase in left ventricular ejection fraction (LVEF) (mean LVEF 36.5% ± 13.3% vs 30.9% ± 13.3%; P < 0.001) and a reduction in left ventricular end-systolic volume (LVESV) (mean LVESV 110.5 ± 57.5 mL vs 89.6 ± 52.4 mL; P < 0.001) compared with baseline existing CRT programming. Conclusion CRT reprogramming to maximize biventricular fusion pacing significantly increased LVEF and reduced LVESV in patients with chronic CRT devices. Further studies are needed to assess if a continuous fusion pacing algorithm improves long-term clinical outcomes and to identify which patients are most likely to derive benefit.
Collapse
|
46
|
Major Adverse Cardiovascular Events Associated With Postoperative Atrial Fibrillation After Noncardiac Surgery. Circ Arrhythm Electrophysiol 2020; 13:e007437. [DOI: 10.1161/circep.119.007437] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
Background:
Postoperative atrial fibrillation (POAF) is a frequent occurrence after noncardiac surgery. It remains unclear whether POAF is associated with an increased risk of major adverse events. We aimed to elucidate the risk of stroke, myocardial infarction, and death associated with POAF following noncardiac surgery by a meta-analysis of randomized controlled studies and observational studies.
Methods:
We searched electronic databases from inception up to August 1, 2019 for all studies that reported stroke or myocardial infarction in adult patients who developed POAF following noncardiac surgery. We used random-effects models to summarize the studies.
Results:
The final analyses included 28 studies enrolling 2 612 816 patients. At 1-month (10 studies), POAF was associated with an ≈3-fold increase in the risk of stroke (weighted mean 2.1% versus 0.7%; odds ratio [OR], 2.82 [95% CI, 2.15–3.70];
P
<0.001). POAF was associated with ≈4-fold increase in the long-term risk of stroke with (weighted mean, 2.0% versus 0.6%; OR, 4.12 [95% CI, 3.32–5.11];
P
≤0.001) in 8 studies with ≥12-month follow-up. There was a significant overall increase in the risk of stroke and myocardial infarction associated with POAF (weighted mean, 2.5% versus 0.9%; OR, 3.44 [95% CI, 2.38–4.98];
P
<0.001) and (weighted mean, 12.6% versus 2.7%; OR, 4.02 [95% CI, 3.08–5.24];
P
<0.001), respectively. Furthermore, POAF was associated with a 3-fold increase in all-cause mortality at 30 days (weighted mean, 15.0% versus 5.4%; OR, 3.36 [95% CI, 2.13–5.31];
P
<0.001).
Conclusions:
POAF was associated with markedly higher risk of stroke, myocardial infarction, and all-cause mortality following noncardiac surgery. Future studies are needed to evaluate the impact of optimal cardiovascular pharmacotherapies to prevent POAF and to decrease the risk of major adverse events in these high-risk patients.
Collapse
|
47
|
Continued vs. interrupted direct oral anticoagulants at the time of device surgery, in patients with moderate to high risk of arterial thrombo-embolic events (BRUISE CONTROL-2). Eur Heart J 2019; 39:3973-3979. [PMID: 30462279 DOI: 10.1093/eurheartj/ehy413] [Citation(s) in RCA: 110] [Impact Index Per Article: 22.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/02/2018] [Accepted: 06/28/2018] [Indexed: 11/13/2022] Open
Abstract
Aims Guidelines recommend warfarin continuation rather than heparin bridging for pacemaker and defibrillator surgery, after the BRUISE CONTROL trial demonstrated an 80% reduction in device pocket haematoma with this approach. However, direct oral anticoagulants (DOACs) are now used to treat the majority of patients with atrial fibrillation. We sought to understand the best strategy to manage the DOACs at the time of device surgery and specifically hypothesized that performing device surgery without DOAC interruption would result in a reduced haematoma rate. Methods and results We randomly assigned patients with atrial fibrillation and CHA2DS2-VASc score ≥2, to continued vs. interrupted DOAC (dabigatran, rivaroxaban, or apixaban). The primary outcome was blindly evaluated, clinically significant device pocket haematoma: resulting in re-operation, interruption of anticoagulation, or prolonging hospital stay. In the continued arm, the median time between pre- and post-operative DOAC doses was 12 h; in the interrupted arm the median time was 72 h. Clinically significant haematoma occurred in of 7 of 328 (2.1%; 95% CI 0.9-4.3) patients in the continued DOAC arm and 7 of 334 (2.1%; 95% CI 0.9-4.3) patients in the interrupted DOAC arm (P = 0.97). Complications were uncommon, and included one stroke and one symptomatic pericardial effusion in each arm. Conclusions These results suggest that, dependent on the clinical scenario, either management strategy (continued DOAC or interrupted DOAC) might be reasonable, at least for patients similar to those enrolled in our trial.
Collapse
|
48
|
Effect of Direct Oral Anticoagulants, Warfarin, and Antiplatelet Agents on Risk of Device Pocket Hematoma: Combined Analysis of BRUISE CONTROL 1 and 2. Circ Arrhythm Electrophysiol 2019; 12:e007545. [PMID: 31610718 DOI: 10.1161/circep.119.007545] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
BACKGROUND Oral anticoagulant use is common among patients undergoing pacemaker or defibrillator surgery. BRUISE CONTROL (Bridge or Continue Coumadin for Device Surgery Randomized Controlled Trial; NCT00800137) demonstrated that perioperative warfarin continuation reduced clinically significant hematomas (CSH) by 80% compared with heparin bridging (3.5% versus 16%). BRUISE-CONTROL-2 (NCT01675076) observed a similarly low risk of CSH when comparing continued versus interrupted direct oral anticoagulant (2.1% in both groups). Using patient level data from both trials, the current study aims to: (1) evaluate the effect of concomitant antiplatelet therapy on CSH, and (2) understand the relative risk of CSH in patients treated with direct oral anticoagulant versus continued warfarin. METHODS We analyzed 1343 patients included in BRUISE-CONTROL-1 and BRUISE-CONTROL-2. The primary outcome for both trials was CSH. There were 408 patients identified as having continued either a single or dual antiplatelet agent at the time of device surgery. RESULTS Antiplatelet use (versus nonuse) was associated with CSH in 9.8% versus 4.3% of patients (P<0.001), and remained a strong independent predictor after multivariable adjustment (odds ratio, 1.965; 95% CI, 1.202-3.213; P=0.0071). In multivariable analysis, adjusting for antiplatelet use, there was no significant difference in CSH observed between direct oral anticoagulant use compared with continued warfarin (odds ratio, 0.858; 95% CI, 0.375-1.963; P=0.717). CONCLUSIONS Concomitant antiplatelet therapy doubled the risk of CSH during device surgery. No difference in CSH was found between direct oral anticoagulant versus continued warfarin. In anticoagulated patients undergoing elective or semi-urgent device surgery, the patient specific benefit/risk of holding an antiplatelet should be carefully considered. CLINICAL TRIAL REGISTRATION URL: https://www.clinicaltrials.gov. Unique identifiers: NCT00800137, NCT01675076.
Collapse
|
49
|
The use of adenosine to identify dormant conduction after accessory pathway ablation: a single center experience and literature review. AMERICAN JOURNAL OF CARDIOVASCULAR DISEASE 2019; 9:84-90. [PMID: 31763060 PMCID: PMC6872466] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 06/04/2019] [Accepted: 09/13/2019] [Indexed: 06/10/2023]
Abstract
INTRODUCTION Atrio-ventricular reentrant tachycardias (AVRT) represent around 40 percent of supraventricular tachycardias. After ablation, recurrence rates are around 10 percent. Adenosine has been described as a useful tool to assess presence of dormant conduction and predict recurrence after apparently successful ablation. We reviewed the patients of our service and assessed the role of adenosine in predicting dormant conduction and factors that could influence recurrence rates. METHODS We retrospectively reviewed electrophysiologic studies and medical charts of 65 patients who had AVRT ablation and had adenosine used to assess dormant conduction at a single quaternary center between 2011 and 2015. Dormant conduction was defined as transient recovery of the preexcitation (for pathways with antegrade conduction) or return of the retrograde conduction through an apparently successfully ablated concealed accessory pathway (AP). RESULTS One patient was found to have dormant conduction (1.5%) with early recurrence that was not further ablated due to the difficult location of the AP. The overall recurrence rate was 4.6%. General features like location of AP's, their properties, ablation times and technique were assessed. CONCLUSION Similar to its use in identifying other arrhythmias, adenosine may be useful in identifying dormant conduction for further ablation during initial ablation of an accessory pathway; however, the absence of dormant conduction on adenosine testing does not reliably predict non-recurrence. The low recurrence rates in our service may be related to the frequent use of irrigated tip catheters, 3D mapping and long average ablation time over the successful site of ablation.
Collapse
|
50
|
Population‐level evaluation of complications after catheter ablation in patients with atrial fibrillation and heart failure. J Cardiovasc Electrophysiol 2019; 30:2678-2685. [DOI: 10.1111/jce.14202] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/16/2019] [Revised: 09/11/2019] [Accepted: 09/26/2019] [Indexed: 12/01/2022]
|