1
|
Effect of drug load on the aerosolisation propensity of binary adhesive mixtures for inhalation. Int J Pharm 2024; 657:124122. [PMID: 38621619 DOI: 10.1016/j.ijpharm.2024.124122] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2024] [Revised: 04/12/2024] [Accepted: 04/12/2024] [Indexed: 04/17/2024]
Abstract
The aim of this study was to investigate how the propensity for aerosolisation in binary adhesive mixtures was affected by the drug load, and to determine whether these findings could be linked to different blend states. Binary blends of two different lactose carriers, each with varying size and morphology, were prepared together with budesonide. In vitro aerosolisation studies were conducted at four different pressure drops, ranging from 0.5 to 4 kPa, utilising a Next Generation Impactor. Several dispersion parameters were derived from the relationship between the quantity of dispersed API and the pressure drop. The evolution of the parameters with drug load was complex, especially at low drug loads. While similar responses were observed for both carriers, the range of drug load that could be used varied significantly. The choice of carrier not only influenced the capacity for drug loading but also affected the spatial distribution of the API within the mixture, which, in turn, affected its aerosolisation propensity. Thus, the drug dispersion process could be linked to different configurations of the lactose carrier and budesonide in the blends, i.e. blend states. In conclusion, the study suggests that the concept of blend states can provide an explanation for the complex dispersion process observed in adhesive blends.
Collapse
|
2
|
The effect of mixing on the dispersibility of adhesive mixtures for inhalation. Comparison of high shear and Turbula mixers. Eur J Pharm Sci 2024; 193:106679. [PMID: 38128841 DOI: 10.1016/j.ejps.2023.106679] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2023] [Revised: 12/15/2023] [Accepted: 12/16/2023] [Indexed: 12/23/2023]
Abstract
This study investigates the effect of different mixers and the applicability of the mixing energy (ME) concept to dry powder formulations for inhalation. With the aim to step-wise build and expand this concept, adhesive mixtures of 2 % budesonide and lactose carrier were investigated, both with 1 % magnesium stearate (MgSt) added in a 'coating' step, and without, the latter referred to as 'naked' formulations. For high shear mixed formulations, the fine particle fraction (FPF) was found to increase with increasing ME up to 60 % and thereafter decreased, using the Novolizer device. The data could be well fitted to the modeling equation, thus confirming the validity of the ME concept. The naked formulations displayed a linear decrease in FPF with increasing ME, again showing the validity of the ME concept. For Turbula mixed formulations, FPF increased with increased mixing time (and mixing energy) for all batches. The naked (binary) composition reached to higher FPF values than for high shear mixing and the formulation with MgSt reached to FPF values around 60 %, demonstrating that it is possible to achieve the same high drug dispersibility with the Turbula mixer as for high shear mixer. An equation for calculation of mixing energy in Turbula mixing was set up in an analogous way to the equation for high shear mixing, which enabled direct comparison between the two mixers.
Collapse
|
3
|
Spray freeze dried niclosamide nanocrystals embedded dry powder for high dose pulmonary delivery. POWDER TECHNOL 2023; 415:118168. [PMID: 36533138 PMCID: PMC9746026 DOI: 10.1016/j.powtec.2022.118168] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 12/09/2022] [Accepted: 12/12/2022] [Indexed: 12/15/2022]
Abstract
Based on the drug repositioning strategy, niclosamide (NCL) has shown potential applications for treating COVID-19. However, the development of new formulations for effective NCL delivery is still challenging. Herein, NCL-embedded dry powder for inhalation (NeDPI) was fabricated by a novel spray freeze drying technology. The addition of Tween-80 together with 1,2-Distearoyl-sn-glycero-3-phosphocholine showed the synergistic effects on improving both the dispersibility of primary NCL nanocrystals suspended in the feed liquid and the spherical structure integrity of the spray freeze dried (SFD) microparticle. The SFD microparticle size, morphology, crystal properties, flowability and aerosol performance were systematically investigated by regulating the feed liquid composition and freezing temperature. The addition of leucine as the aerosol enhancer promoted the microparticle sphericity with greatly improved flowability. The optimal sample (SF- 80D-N20L2D2T1) showed the highest fine particle fraction of ∼47.83%, equivalently over 3.8 mg NCL that could reach the deep lung when inhaling 10 mg dry powders.
Collapse
|
4
|
Increasing the fine particle fraction of pressurised metered dose inhaler solutions with novel actuator shapes. Int J Pharm 2021; 597:120341. [PMID: 33545289 DOI: 10.1016/j.ijpharm.2021.120341] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2020] [Revised: 01/20/2021] [Accepted: 01/31/2021] [Indexed: 11/16/2022]
Abstract
In this paper we demonstrate that the use of multiple orifices can improve the fine particle fraction (FPF) of pressurised metered-dose inhaler solution formulations by up to 75% when compared to a single orifice with an equivalent cross sectional area (p<0.05). While prior work has relied on metal actuator components, improvements in micro injection moulding and micro drilling now make it possible to mass produce novel orifice shapes to achieve similar FPF gains in plastic parts, with orifice diameters less than 0.2 mm. The ability to create internal features inside the actuator is also demonstrated. We show through in vitro high speed imaging that twin orifice sprays merge quickly and act as a single, modified plume. We also show for the first time that FPF and fine particle dose (FPD) are strongly correlated with the distance at which the plume velocity decays to half its initial value (R2=0.997 and 0.95 respectively). When plume velocity & FPF are increased, mouthpiece deposition decreases. This suggests that while smaller orifices produce more fine particles, higher sustained plume velocities also entrain more of the fine particles produced at the periphery of the spray due to increased shear. The effect occurs within the mouthpiece and is thus unlikely to alter the flow field in the upper airway.
Collapse
|
5
|
On the relationship between blend state and dispersibility of adhesive mixtures containing active pharmaceutical ingredients. Int J Pharm X 2021; 3:100069. [PMID: 33409485 PMCID: PMC7773864 DOI: 10.1016/j.ijpx.2020.100069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
The objectives of this investigation were to study the evolution in blend state of adhesive mixtures containing the active pharmaceutical ingredients (APIs) salbutamol, budesonide and AZD5423 and to study the relationship between blend state and dispersibility of the mixtures, as assessed by the fine particle fraction (FPF). A series of adhesive mixtures of varied fines concentration were prepared for each API using the same type of carrier. Based on visual examination and powder mechanics, blend states were identified and summarized as blend state maps for each API. The dispersibility of the mixtures was studied using a Fast Screening Impactor (FSI) equipped with a ScreenHaler. The evolution in blend state differed between the APIs in terms of the width of the blend states. The structure of the adhesion layer also differed between the APIs, from relatively uniform to a heterogeneous layer with small agglomerates dispersed on the carrier surface. All three APIs expressed a similar type of bended relationship between FPF and fines concentration. However, the initial rate of increase and the fines concentration of the plateau differed between the APIs. The adhesive mixtures of all APIs followed the three main states in terms of structural evolution and the overall shape of the FPF-fines concentration profiles could be explained by the evolution in blend state. It is proposed that the structure of the adhesion layer is an important factor explaining the differences in blend state - blend dispersibility relationships between the APIs.
Collapse
|
6
|
Spherical agglomerates of lactose as potential carriers for inhalation. Eur J Pharm Biopharm 2020; 159:11-20. [PMID: 33358941 DOI: 10.1016/j.ejpb.2020.12.015] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2020] [Revised: 12/02/2020] [Accepted: 12/15/2020] [Indexed: 11/21/2022]
Abstract
We report here on spherical lactose agglomerates as potential carriers for inhalation applications. Micromeritic properties of three spherical lactose agglomerates (SA-A, SA-B, SA-C) and a standard lactose inhalation grade carrier (Lactohale 100; LH100) were evaluated and compared. Ordered mixtures with micronized salbutamol sulfate as the model active pharmaceutical ingredient (API) and lactose carriers at two drug loadings (2 wt%, 5 wt%) were prepared, and in-vitro aerosolization performance was assessed. The spherical crystallization process led to particles with tailored micromeritic properties. These had larger specific surface area and greater fine fraction < 10 µm, compared to LH100, due to their coarse morphology. Their properties were reflected in the flowability parameters, where two types of spherical agglomerates of lactose showed more cohesive behavior compared to the other lactose grades. Blend uniformity showed improved homogeneous distribution of the API at higher drug load. In-vitro aerosolization tests showed that the spherical agglomerates of lactose enhanced the dose of API, compared to LH100. SA-B and SA-C showed significantly higher fine particle fractions at low drug load compared to the others, whereas overall, the largest fine particle fraction was for SA-B at high drug load. The carrier material attributes related to particle size, specific surface area, compressibility, flowability (cohesion, flow function), and air permeability were critical for aerosolization performance.
Collapse
|
7
|
Does upper airway deformation affect drug deposition? Int J Pharm 2019; 572:118773. [PMID: 31678391 DOI: 10.1016/j.ijpharm.2019.118773] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2019] [Revised: 09/18/2019] [Accepted: 10/07/2019] [Indexed: 12/17/2022]
Abstract
Knowledge that enables the accurate simulation of drug deposition in the human upper airway is necessary to develop robust platforms for efficient drug delivery by inhalation devices. The human upper airway is deformable during inhalation but how it could affect the deposition of inhaled drugs is unknown. We aimed to determine whether pharyngeal deformation at the soft palate level would have any significant effects on throat deposition, in vitro lung dose and fine particle fraction. In this study, dry mannitol powders were delivered to the next-generation cascade impactor (NGI) through the United States Pharmacopeia (USP) throat, and a realistic upper airway cast (RUPAC) at flow rates of 40, 60 and 80 L min-1. Deformation of the upper airway at 25%, 50%, and 75% in the lateral and antero-posterior directions were experimentally simulated in the RUPAC. Throat deposition (p = 0.04) is significantly affected when the upper airway deforms laterally but not antero-posteriorly.
Collapse
|
8
|
Chitosan-based binary dry powder inhaler carrier with nanometer roughness for improving in vitro and in vivo aerosolization performance. Drug Deliv Transl Res 2018; 8:1274-1288. [PMID: 30112607 DOI: 10.1007/s13346-018-0564-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
Suitable nanometer roughness favors interactions between drugs and carriers, and it is a promising approach to enhance the aerosolization performance of carrier-based dry powder inhalers (DPIs). In this study, by altering the molecular migration rates, chitosan-based binary carriers (CBBCs) with nanometer roughness were fabricated for DPIs. Comprehensive physicochemical characterizations were conducted to elucidate the formation mechanism of the CBBCs. It was hypothesized that different constituent ratios in the formulations would result in different assembling of the particles and diverse roughness scales. The fine particle fractions (FPF, approximately 40~60%) of nanometer roughness CBBC-based DPI formulations were satisfactory, demonstrating the enhancement of the in vitro aerodynamic performance. The positive correlation (R2 = 0.9883) between the nanometer roughness and FPF was revealed, and the surface roughness of 20 nm might achieve the best aerosolization performance. CBBCs (optimal formulations) showed no difference in cytotoxicity on A549 and Calu-3 cells (p > 0.05). Additionally, the increased Cmax and AUC0-8h of the formulation with the nanometer roughness (p < 0.05) were observed in pharmacokinetic studies, which resulted from the improved in vivo aerosolization performance. In summary, the CBBCs were a prospective tool to improve the in vitro and in vivo aerosolization performance of DPIs. Graphical abstract ᅟ.
Collapse
|
9
|
In vitro and clinical characterization of the valved holding chamber AeroChamber Plus ® Flow-Vu ® for administrating tiotropium Respimat ® in 1-5-year-old children with persistent asthmatic symptoms. Respir Med 2018; 137:181-190. [PMID: 29605203 DOI: 10.1016/j.rmed.2018.03.010] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/13/2018] [Revised: 03/02/2018] [Accepted: 03/05/2018] [Indexed: 11/18/2022]
Abstract
BACKGROUND When characterizing inhalation products, a comprehensive assessment including in vitro, pharmacokinetic (PK), and clinical data is required. We conducted a characterization of tiotropium Respimat® when administered with AeroChamber Plus® Flow-Vu® anti-static valved holding chamber (test VHC) with face mask in 1-5-year-olds with persistent asthmatic symptoms. METHODS In vitro tiotropium dose and particle size distribution delivered into a cascade impactor were evaluated under fixed paediatric and adult flow rates between actuation and samplings. The tiotropium mass likely to reach children's lungs was assessed by tidal breathing simulations and an ADAM-III Child Model. PK exposure to tiotropium in preschool children with persistent asthmatic symptoms (using test VHC) was compared with pooled data from nine Phase 2/3 trials in older children, adolescents, and adults with symptomatic persistent asthma not using test VHC. RESULTS At fixed inspiratory flow rates, emitted mass and fine particle dose decreased under lower flow conditions; dose reduction was observed when Respimat® was administered by test VHC at paediatric flow rates. In <5-year-old children, such a dose reduction is appropriate. In terms of dose per kg/body weight, in vitro-delivered dosing in children was comparable with adults. Transmission and aerosol holding properties of Respimat® when administered with test VHC were fully sufficient for aerosol delivery to patients. At zero delay, particles <5 μm (most relevant fraction) exhibited a transfer efficacy of ≥60%. The half-time was>10 s, allowing multiple breaths. Standardized tidal inhalation resulted in an emitted mass from the test VHC of approximately one-third of labelled dose, independent of coordination and face mask use, indicating predictable tiotropium administration by test VHC with Respimat®. Tiotropium exposure in 1-5-year-old patients using the test VHC, when adjusted by height or body surface, was comparable with that in older age groups without VHCs; no overexposure was observed. Adverse events were less frequent with tiotropium (2.5 μg, n = 20 [55.6%]; 5 μg, n = 18 [58.1%]) than placebo (n = 25 [73.5%]). CONCLUSIONS Our findings provide good initial evidence to suggest that tiotropium Respimat® may be administered with AeroChamber Plus® Flow-Vu® VHC in 1-5-year-old patients with persistent asthmatic symptoms. To confirm the clinical efficacy and safety in these patients, additional trials are required. CLINICAL TRIALS REGISTRY NUMBER The trial was registered under NCT01634113 at http://www.clinicaltrials.gov.
Collapse
|
10
|
Dry powder aerosols to co-deliver antibiotics and nutrient dispersion compounds for enhanced bacterial biofilm eradication. Int J Pharm 2017; 531:14-23. [PMID: 28826725 DOI: 10.1016/j.ijpharm.2017.08.060] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2017] [Revised: 07/20/2017] [Accepted: 08/02/2017] [Indexed: 02/01/2023]
Abstract
The purpose of this study was to formulate a dry powder for inhalation containing a combination treatment for eradication of Pseudomonas aeruginosa bacterial biofilms. Dry powders containing an antibiotic (ciprofloxacin hydrochloride, CH) and nutrient dispersion compound (glutamic acid, GA) at a ratio determined to eliminate the biofilms were generated by spray drying. Leucine was added to the spray dried formulation to aid powder flowability. A central composite design of experiments was performed to determine the effects of solution and processing parameters on powder yield and aerodynamic properties. Combinations of CH and GA eradicated bacterial biofilms at lower antibiotic concentrations compared to CH alone. Spray dried powders were produced with yields up to 43% and mass mean aerodynamic diameters (MMAD) in the respirable range. Powder yield was primarily affected by variables that determine cyclone efficiency, i.e. atomizer and solution flow rates and solution concentration; while MMAD was mainly determined by solution concentration. Fine particle fractions (FPF)<4.46μm and <2.82μm of the powders ranged from 56 to 70% and 35 to 46%, respectively. This study demonstrates that dry powder aerosols containing high concentrations of a combination treatment effective against P. aeruginosa biofilms could be developed with high yield, aerodynamic properties appropriate for inhalation, and no loss of potency.
Collapse
|
11
|
L-Leucine as an excipient against moisture on in vitro aerosolization performances of highly hygroscopic spray-dried powders. Eur J Pharm Biopharm 2016; 102:132-41. [PMID: 26970252 DOI: 10.1016/j.ejpb.2016.02.010] [Citation(s) in RCA: 111] [Impact Index Per Article: 13.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2015] [Revised: 02/17/2016] [Accepted: 02/18/2016] [Indexed: 11/29/2022]
Abstract
L-Leucine (LL) has been widely used to enhance the dispersion performance of powders for inhalation. LL can also protect powders against moisture, but this effect is much less studied. The aim of this study was to investigate whether LL could prevent moisture-induced deterioration in in vitro aerosolization performances of highly hygroscopic spray-dried powders. Disodium cromoglycate (DSCG) was chosen as a model drug and different amounts of LL (2-40% w/w) were added to the formulation, with the aim to explore the relationship between powder dispersion, moisture protection and physicochemical properties of the powders. The powder formulations were prepared by spray drying of aqueous solutions containing known concentrations of DSCG and LL. The particle sizes were measured by laser diffraction. The physicochemical properties of fine particles were characterized by X-ray powder diffraction (XRD), differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), and dynamic vapor sorption (DVS). The surface morphology and chemistry of fine particles were analyzed by scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), and time-of-flight secondary ion mass spectrometry (ToF-SIMS). In vitro aerosolization performances were evaluated by a next generation impactor (NGI) after the powders were stored at 60% or 75% relative humidity (RH), and 25°C for 24h. Spray-dried (SD) DSCG powders were amorphous and absorbed 30-45% (w/w) water at 70-80% RH, resulting in deterioration in the aerosolization performance of the powders. LL did not decrease the water uptake of DSCG powders, but it could significantly reduce the effect of moisture on aerosolization performances. This is due to enrichment of crystalline LL on the surface of the composite particles. The effect was directly related to the percentage of LL coverage on the surface of particles. Formulations having 61-73% (molar percent) of LL on the particle surface (which correspond to 10-20% (w/w) of LL in the bulk powders) could minimize moisture-induced deterioration in the aerosol performance. In conclusion, particle surface coverage of LL can offer short-term protection against moisture on dispersion of hygroscopic powders.
Collapse
|
12
|
Influence of surface characteristics of modified glass beads as model carriers in dry powder inhalers (DPIs) on the aerosolization performance. Drug Dev Ind Pharm 2015; 41:1710-7. [PMID: 25632978 DOI: 10.3109/03639045.2014.997246] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
The aim of this work is to investigate the effect of surface characteristics (surface roughness and specific surface area) of surface-modified glass beads as model carriers in dry powder inhalers (DPIs) on the aerosolization, and thus, the in vitro respirable fraction often referred to as fine particle fraction (FPF). By processing glass beads in a ball mill with different grinding materials (quartz and tungsten carbide) and varying grinding time (4 h and 8 h), and by plasma etching for 1 min, glass beads with different shades of surface roughness and increased surface area were prepared. Compared with untreated glass beads, the surface-modified rough glass beads show increased FPFs. The drug detachment from the modified glass beads is also more reproducible than from untreated glass beads indicated by lower standard deviations for the FPFs of the modified glass beads. Moreover, the FPF of the modified glass beads correlates with their surface characteristics. The higher the surface roughness and the higher the specific surface area of the glass beads the higher is the FPF. Thus, surface-modified glass beads make an ideal carrier for tailoring the performance of DPIs in the therapy of asthma and chronically obstructive pulmonary diseases.
Collapse
|
13
|
Dry powder inhalers: physicochemical and aerosolization properties of several size-fractions of a promising alterative carrier, freeze-dried mannitol. Eur J Pharm Sci 2014; 68:56-67. [PMID: 25497318 DOI: 10.1016/j.ejps.2014.12.005] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2014] [Revised: 12/01/2014] [Accepted: 12/02/2014] [Indexed: 11/24/2022]
Abstract
The purpose of this work was to evaluate the physicochemical and inhalation characteristics of different size fractions of a promising carrier, i.e., freeze-dried mannitol (FDM). FDM was prepared and sieved into four size fractions. FDMs were then characterized in terms of micromeritic, solid-state and bulk properties. Dry powder inhaler (DPI) formulations were prepared using salbutamol sulphate (SS) and then evaluated in terms of drug content homogeneity and in vitro aerosolization performance. The results showed that the crystalline state of mannitol was maintained following freeze-drying for all size fractions of FDM. All FDM particles showed elongated morphology and contained mixtures of α-, β- and δ-mannitol. In comparison to small FDM particles, FDMs with larger particle sizes demonstrated narrower size distributions, higher bulk and tap densities, lower porosities and better flowability. Regardless of particle size, all FDMs generated a significantly higher (2.2-2.9-fold increase) fine particle fraction (FPF, 37.5 ± 0.9%-48.6 ± 2.8%) of SS in comparison to commercial mannitol. The FPFs of SS were related to the shape descriptors of FDM particles; however, FPFs did not prove quantitative apparent relationships with either particle size or powder bulk descriptors. Large FDM particles were more favourable than smaller particles because they produced DPI formulations with better flowability, better drug content homogeneity, lower amounts of the drug depositing on the throat and contained lower fine-particle-mannitol. Optimized stable DPI formulations with superior physicochemical and pharmaceutical properties can be achieved using larger particles of freeze-dried mannitol (FDM).
Collapse
|
14
|
The clinical relevance of dry powder inhaler performance for drug delivery. Respir Med 2014; 108:1195-203. [PMID: 24929253 DOI: 10.1016/j.rmed.2014.05.009] [Citation(s) in RCA: 97] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/29/2014] [Revised: 05/08/2014] [Accepted: 05/13/2014] [Indexed: 01/27/2023]
Abstract
BACKGROUND Although understanding of the scientific basis of aerosol therapy with dry powder inhalers (DPIs) has increased, some misconceptions still persist. These include the beliefs that high resistance inhalers are unsuitable for some patients, that extra fine (<1.0 μm) particles improve peripheral lung deposition and that inhalers with flow rate-independent fine particle fractions (FPFs) produce a more consistent delivered dose to the lungs. OBJECTIVES This article aims to clarify the complex inter-relationships between inhaler design and resistance, inspiratory flow rate (IFR), FPF, lung deposition and clinical outcomes, as a better understanding may result in a better choice of DPI for individual patients. METHODS The various factors that determine the delivery of drug particles into the lungs are reviewed. These include aerodynamic particle size distribution, the inspiratory manoeuvre, airway geometry and the three basic principles that determine the site and extent of deposition: inertial impaction, sedimentation and diffusion. DPIs are classed as either dependent or independent of inspiratory flow rate and vary in their internal resistance to inspiration. The effects of these characteristics on drug deposition in the airways are described using data from studies directly comparing currently available inhaler devices. RESULTS Clinical experience shows that most patients can use a high resistance DPI effectively, even during exacerbations. Particles in the aerodynamic size range from 1.5-5 μm are shown to be optimal, as particles <1.0 μm are very likely to be exhaled again while those >5 μm may impact on the oropharynx. For DPIs with a constant FPF at all flow rates, less of the delivered dose reaches the central and peripheral lung when the flow rate increases, risking under-dosing of the required medication. In contrast, flow rate-dependent inhalers increase their FPF output at higher flow rates, which compensates for the greater impaction on the upper airways as flow rate increases. CONCLUSIONS The technical characteristics of different inhalers and the delivery and deposition of the fine particle dose to the lungs may be important additional considerations to help the physician to select the most appropriate device for the individual patient to optimise their treatment.
Collapse
|
15
|
Deposition and fine particle production during dynamic flow in a dry powder inhaler: a CFD approach. Int J Pharm 2013; 461:129-36. [PMID: 24296048 DOI: 10.1016/j.ijpharm.2013.11.047] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2013] [Revised: 11/21/2013] [Accepted: 11/24/2013] [Indexed: 10/25/2022]
Abstract
In this work the dynamic flow as well as the particle motion and deposition in a commercial dry powder inhaler, DPI (i.e., Turbuhaler) is described using computational fluid dynamics, CFD. The dynamic flow model presented here is an extension of a steady flow model previously described in Milenkovic et al. (2013). The model integrates CFD simulations for dynamic flow, an Eulerian-fluid/Lagrangian-particle description of particle motion as well as a particle/wall interaction model providing the sticking efficiency of particles colliding with the DPI walls. The dynamic flow is imposed by a time varying outlet pressure and the particle injections into the DPI are assumed to occur instantaneously and follow a prescribed particle size distribution, PSD. The total particle deposition and the production of fine particles in the DPI are determined for different peak inspiratory flow rates, PIFR, flow increase rates, FIR, and particle injection times. The simulation results for particle deposition are found to agree well with available experimental data for different values of PIFR and FIR. The predicted values of fine particle fraction are in agreement with available experimental results when the mean size of the injected PSD is taken to depend on the PIFR.
Collapse
|