1
|
On-Chip Fabrication-Tolerant Exceptional Points Based on Dual-Scatterer Engineering. NANO LETTERS 2024; 24:3906-3913. [PMID: 38506264 DOI: 10.1021/acs.nanolett.3c05075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/21/2024]
Abstract
The intriguing and anomalous optical characteristics of exceptional points (EPs) in optical resonators have attracted significant attention. While EP-related phenomena have been observed by perturbing resonators with off-chip components, implementing EPs fully on-chip remains challenging due to their extreme susceptibility to fabrication errors. In this Letter, we propose a succinct and compact approach to reach EP in an on-chip integrated silicon microring resonator by manipulating the evolution of backscatterings with two nanocylinders of disparate diameters. The theoretical analysis unveils that the fabrication constraints could be significantly relieved by increasing the difference in diameters of the nanocylinders. The evolution from non-EP to EP is traced experimentally through the step-by-step tuning of the angular and radial positions of nanocylinders. The proposed method opens a pathway toward the on-chip high-density integration of non-Hermitian devices.
Collapse
|
2
|
A Wireless Passive Pressure-Sensing Method for Cryogenic Applications Using Magnetoresistors. SENSORS (BASEL, SWITZERLAND) 2024; 24:717. [PMID: 38339434 PMCID: PMC10857315 DOI: 10.3390/s24030717] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Revised: 01/12/2024] [Accepted: 01/22/2024] [Indexed: 02/12/2024]
Abstract
In this study, we developed a novel wireless, passive pressure-sensing method functional at cryogenic temperatures (-196 °C). The currently used pressure sensors are inconvenient and complicated in cryogenic environments for their weak low-temperature tolerances and long wires for power supply and data transmission. We propose a novel pressure-sensing method for cryogenic applications by only using low-temperature-tolerant passive devices. By innovatively integrating a magnetoresistor (MR) on a backscattering antenna, the pressure inside a cryogenic environment is transferred to a wirelessly obtainable return loss. Wireless passive measurement is thus achieved using a backscattering method. In the measurement, the pressure causes a relative displacement between the MR and a magnet. The MR's resistance changes with the varied magnetic field, thus modulating the antenna's return loss. The experimental results indicate that our fabricated sensor successfully identified different pressures, with high sensitivities of 4.3 dB/MPa at room temperature (24 °C) and 1.3 dB/MPa at cryogenic temperature (-196 °C). Additionally, our method allows for simultaneous wireless readings of multi sensors via a single reading device by separating the frequency band of each sensor. Our method performs low-cost, simple, robust, passive, and wireless pressure measurement at -196 °C; thus, it is desirable for cryogenic applications.
Collapse
|
3
|
Experimental Characterization of Polarized Light Backscattering in Fog Environments. SENSORS (BASEL, SWITZERLAND) 2023; 23:8896. [PMID: 37960595 PMCID: PMC10649006 DOI: 10.3390/s23218896] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Revised: 10/24/2023] [Accepted: 10/30/2023] [Indexed: 11/15/2023]
Abstract
This paper focuses on the experimental characterization of the polarization behavior of light backscattered through fog. A polarimetric orthogonal state contrast imager and an active, purely polarized white illuminator system are used to evaluate both linear and circular polarization signals. The experiments are carried out in a macro-scale fog chamber under controlled artificial fog conditions. We explore the effect of backscattering in each imaging channel, and the persistence of both polarization signals as a function of meteorological visibility. We confirm the presence of the polarization memory effect with circularly polarized light, and, as a consequence, the maintenance of helicity in backscattering. Moreover, the circular cross-polarized channel is found to be the imaging channel less affected by fog backscattering. These results are useful and should be taken into account when considering active polarimetric imaging techniques for outdoor applications under foggy conditions.
Collapse
|
4
|
A Methodology to Model the Rain and Fog Effect on the Performance of Automotive LiDAR Sensors. SENSORS (BASEL, SWITZERLAND) 2023; 23:6891. [PMID: 37571674 PMCID: PMC10422612 DOI: 10.3390/s23156891] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Revised: 07/24/2023] [Accepted: 07/28/2023] [Indexed: 08/13/2023]
Abstract
In this work, we introduce a novel approach to model the rain and fog effect on the light detection and ranging (LiDAR) sensor performance for the simulation-based testing of LiDAR systems. The proposed methodology allows for the simulation of the rain and fog effect using the rigorous applications of the Mie scattering theory on the time domain for transient and point cloud levels for spatial analyses. The time domain analysis permits us to benchmark the virtual LiDAR signal attenuation and signal-to-noise ratio (SNR) caused by rain and fog droplets. In addition, the detection rate (DR), false detection rate (FDR), and distance error derror of the virtual LiDAR sensor due to rain and fog droplets are evaluated on the point cloud level. The mean absolute percentage error (MAPE) is used to quantify the simulation and real measurement results on the time domain and point cloud levels for the rain and fog droplets. The results of the simulation and real measurements match well on the time domain and point cloud levels if the simulated and real rain distributions are the same. The real and virtual LiDAR sensor performance degrades more under the influence of fog droplets than in rain.
Collapse
|
5
|
Investigation on Modulation-Based Straightness Measurement. SENSORS (BASEL, SWITZERLAND) 2023; 23:2912. [PMID: 36991623 PMCID: PMC10053020 DOI: 10.3390/s23062912] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/10/2022] [Revised: 02/10/2023] [Accepted: 03/02/2023] [Indexed: 06/19/2023]
Abstract
The concept of a novel non-contacting technique for measuring straightness and its practical realization in a mechanical device are presented in this article. The device, called InPlanT, is based on the acquisition of the luminous signal retroreflected by a spherical glass target and impinged on a photodiode after mechanical modulation. The received signal is reduced to the sought straightness profile using dedicated software. The system was characterized with a high-accuracy CMM and the maximum error of indication was derived.
Collapse
|
6
|
Radio Frequency Identification Temperature/CO 2 Sensor Using Carbon Nanotubes. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:273. [PMID: 36678026 PMCID: PMC9864907 DOI: 10.3390/nano13020273] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/29/2022] [Revised: 12/18/2022] [Accepted: 12/20/2022] [Indexed: 06/17/2023]
Abstract
In the world of digitization, different objects cooperate with the Internet of Things (IoT); these objects also amplify using sensing and data processing structures. Radio frequency identification (RFID) has been identified as a key enabler technology for IoT. RFID technology has been used in different conventional applications for security, goods storage, transportation and asset management. In this paper, a fully inkjet-printed chipless radio frequency identification (RFID) sensor tag is presented for the wireless identification of tagged objects. The dual polarized tag consists of two resonating structures functioning wirelessly. One resonator works for encoding purpose and other resonator is used as a CO2/temperature sensor. The sensing behavior of the tag relies on the integration of a meandered structure comprising of multi-wall carbon nanotubes (MWCNT). The MWCNT is highly sensitive to CO2 gas. The backscattered response of the square-shaped cascaded split ring resonators (SRR) is analyzed through a radar cross-section (RCS) curve. The overall tag dimension is 42.1 mm × 19.5 mm. The sensing performance of the tag is examined and optimized for two different flexible substrates, i.e., PET and Kapton®HN. The flexible tag structure has the capability to transmit 5-bit data in the frequency bands of 2.36-3.9 GHz and 2.37-3.89 GHz, for PET and Kapton®HN, respectively. The proposed chipless RFID sensor tag does not require any microchip or a power source, so it has a great potential for low-cost and automated temperature/CO2 sensing applications.
Collapse
|
7
|
Spray-Dried Infant Formula Emulsion Stability as Affected by Pre-Heat Treatment and Total Solids Content of the Feed. Foods 2022; 11:foods11233752. [PMID: 36496560 PMCID: PMC9737341 DOI: 10.3390/foods11233752] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Revised: 11/10/2022] [Accepted: 11/12/2022] [Indexed: 11/23/2022] Open
Abstract
Pre-spray-drying processing may affect stability after reconstitution of emulsion-based powders, such as infant formulas. This study aimed to evaluate the effects of pasteurization temperature and total solids (TS) of the feed on the stability of the emulsions obtained from the reconstituted powders. Four infant formula powders (50%-75 °C, 50%-100 °C, 60%-75 °C, and 60%-100 °C) were produced at pilot scale, from emulsions with 50 or 60% TS pasteurized at 75 or 100 °C for 18 s. Both the emulsion feeds and the emulsions from the reconstituted powders (12.5% TS) were analyzed. The results showed that feeds with 60% TS were flocculated, as indicated by the large particle size and viscosity and the pseudoplastic behavior. Light microscopy revealed that, during spray drying, the flocs were disrupted in 60%-100 °C, while the 60%-75 °C emulsion remained flocculated, reducing its stability post-reconstitution. Although all four emulsions were mainly stabilized by caseins, the presence of β-lactoglobulin was also detected at the oil-water interface, in native state in the formulas preheated at 75 °C and aggregated in the formulas preheated at 100 °C. In conclusion, both the degree of whey protein denaturation (resulting from pasteurization) and the TS of the concentrates during infant formula production affected the emulsion stability of the reconstituted powders.
Collapse
|
8
|
Optical Modeling of Single Asian Dust and Marine Air Particles: A Comparison with Geometric Particle Shapes for Remote Sensing. JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER 2022; 254:10.1016/j.jqsrt.2020.107197. [PMID: 38567026 PMCID: PMC10986421 DOI: 10.1016/j.jqsrt.2020.107197] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/04/2024]
Abstract
We compare the optical properties of various geometric shapes with single atmospheric Asian dust and marine background air particles collected at Mauna Loa Observatory. Three-dimensional representations of the particles were acquired with focused ion-beam (FIB) tomography, which involves FIB milling of individual particles followed by imaging and elemental mapping with scanning electron microscopy. Particles were heterogeneous with mainly dolomite or calcite and a minor amount of iron; marine air particles contained gypsum but no iron. Extinction and backscatter fraction were calculated with the discrete dipole approximation method. Geometric shapes were grouped as ellipsoids (sphere, spheroid, ellipsoid), cuboids (cube, square prism, rectangular prism), and pyramids (tetrahedron, triangular pyramid). Each group represented a progression of shapes with 1, 2, or 3 non-identical axes. Most shapes underestimated particle extinction and overestimated the backscatter fraction. Not surprisingly, extinction and the backscatter fraction of the sphere and cube were furthest from those of the particles. While the 3-axis ellipsoid and rectangular prism were closer dimensionally to the particles, extinction and the backscatter fraction for the 2-axis spheroid and square prism, respectively, were often closer to the particles. The extinction and backscatter fraction for the tetrahedron and triangular pyramid were closer on average to the actual particles than were the other shapes. Tetrahedra have the advantage that parameterization of an aerosol model for remote sensing would not require an aspect ratio distribution. Particle surface roughness invariably decreased the backscatter fraction. While surface roughness typically contributes a minor part to overall scattering, in some cases the larger surface area of the tetrahedron and triangular pyramid sufficiently accounted for enhanced forward scattering of particles from surface roughness.
Collapse
|
9
|
Ultrasonic Monitoring of the Water Content in Concentrated Water-Petroleum Emulsions Using the Slope of the Phase Spectrum. SENSORS (BASEL, SWITZERLAND) 2022; 22:7236. [PMID: 36236335 PMCID: PMC9572599 DOI: 10.3390/s22197236] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/04/2022] [Revised: 09/04/2022] [Accepted: 09/15/2022] [Indexed: 06/16/2023]
Abstract
This work proposes the slope of the phase spectrum as a signal processing parameter for the ultrasonic monitoring of the water content of water-in-crude oil emulsions. Experimental measurements, with water volume fractions from 0 to 0.48 and test temperatures of 20 °C, 25 °C, and 30 °C, were carried out using ultrasonic measurement devices operating in transmission-reception and backscattering modes. The results show the phase slope depends on the water volume fraction and, to a lesser extent, on the size of the emulsion droplets, leading to a stable behavior over time. Conversely, the behavior of the phase slope as a function of the volume fraction is monotonic with low dispersion. Fitting a power function to the experimental data provides calibration curves that can be used to determine the water content with percentage relative error up to 70% for a water volume fraction of 0.06, but less than 10% for water volume fractions greater than 0.06. Furthermore, the methodology works over a wide range of volume fractions.
Collapse
|
10
|
Intracameral Microimaging of Maturation of Human iPSC Derivatives into Islet Endocrine Cells. Cell Transplant 2022; 31:9636897211066508. [PMID: 35156411 PMCID: PMC8848082 DOI: 10.1177/09636897211066508] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
We exploited the anterior chamber of the eye (ACE) of immunodeficient mice as an ectopic site for both transplantation and microimaging of engineered surrogate islets from human induced pluripotent stem cells (hiPSC-SIs). These islets contained a majority of insulin-expressing cells, positive or negative for PDX1 and NKX6.1, and a minority of glucagon- or somatostatin-positive cells. Single, non-aggregated hiPSC-SIs were satisfactorily engrafted onto the iris. They underwent gradual vascularization and progressively increased their light scattering signals, reflecting the abundance of zinc-insulin crystal packaged inside mature insulin secretory granules. Intracameral hiPSC-SIs retrieved from recipients showed enhanced insulin immunofluorescence in correlation with the parallel increase in overall vascularization and light backscattering during the post-transplantation period. This approach enables longitudinal, nondestructive and intravital microimaging of cell fates, engraftment, vascularization and mature insulin secretory granules of single hiPSC-SI grafts, and may offer a feasible and reliable means to screen compounds for promoting in vivo hiPSC-SI maturation.
Collapse
|
11
|
The Imprint of Primary Production on High-Frequency Profiles of Lake Optical Properties. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2021; 55:14234-14244. [PMID: 34591466 DOI: 10.1021/acs.est.1c02585] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Water inherent optical properties (IOPs) contain integrative information on the optical constituents of surface waters. In lakes, IOP measurements have not been traditionally collected. This study describes how high-frequency IOP profiles can be used to document short-term physical and biogeochemical processes that ultimately influence the long-term trajectory of lake ecosystems. Between October 2018 and May 2020, we collected 1373 high-resolution hyperspectral IOP profiles in the uppermost 50 m of the large mesotrophic Lake Geneva (Switzerland-France), using an autonomous profiler. A data set of this size and content does not exist for any other lake. Results showed seasonal variations in the IOPs, following the expected dynamic of phytoplankton. We found systematic diel patterns in the IOPs. Phases of these diel cycles were consistent year-round, and amplitudes correlated to the diurnal variations of dissolved oxygen, clarifying the link between IOPs and phytoplankton metabolism. Diel amplitudes were largest in spring and summer under low wind condition. Wind-driven changes in thermal stratification impacted the dynamic of the IOPs, illustrating the potential of high-frequency profiles of water optical properties to increase our understanding of carbon cycling in lake ecosystems.
Collapse
|
12
|
[Review on wetland water level monitoring using interferometric synthetic aperture radar]. YING YONG SHENG TAI XUE BAO = THE JOURNAL OF APPLIED ECOLOGY 2021; 31:2841-2848. [PMID: 34494807 DOI: 10.13287/j.1001-9332.202008.035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
Water level is an important indicator of wetland hydrological regime. Detection of wetland water levels through interferometric synthetic aperture radar (InSAR) has outstanding advantage, including high spatial resolution, high accuracy, low cost, and high efficiency. We introduced prerequisites for the monitoring of wetland water levels with InSAR, discussed the types of InSAR techniques, the influencing factors for monitoring wetland water levels and their advantages and disadvantages. There are three prerequisites for effectively detecting wetland water levels with InSAR techniques: 1) the presence of emergent aquatic plants; 2) the main backscattering mechanism is double bounce scattering; and 3) the interferometric coherence exceeds a certain threshold. Current water level monitoring techniques have been developed from traditional InSAR techniques to advanced InSAR techniques, such as STBAS, MM, and DSI. These techniques evolve from detecting relative water level changes to estimate absolute water level and water depth time series. The influencing factors of InSAR techniques for monitoring wetland water levels include operating para-meters of the synthetic aperture radar (SAR) and characteristics of the wetlands themselves. Finally, we proposed the key directions for future research in this field: i) investigating the potential use of specific water level monitoring techniques in other regions with different backscattering and interferometric coherence characteristics; ii) developing new algorithms to integrate multi-sensor, multi-track, multi-band, multi-polarization, and multi-temporal InSAR repeat-pass observation; iii) considering alternative sources of SAR data; and (iv) strengthening research on "by-products" of wetland water level monitoring with InSAR, such as wetland hydrological connectivity, flow direction, and flow regime.
Collapse
|
13
|
A Low-Cost Active Reflector for Interferometric Monitoring Based on Sentinel-1 SAR Images. SENSORS 2021; 21:s21062008. [PMID: 33809112 PMCID: PMC8001941 DOI: 10.3390/s21062008] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/29/2021] [Revised: 03/01/2021] [Accepted: 03/09/2021] [Indexed: 11/16/2022]
Abstract
The effectiveness of radar interferometric techniques in non-urban areas can often be compromised due to the lack of stable natural targets. This drawback can be partially compensated through the installation of reference targets, characterized by a bright and stable radar response. The installation of passive corner reflectors (PCR) often represents a valid aid, but these objects are usually cumbersome, and suffer from severe weather conditions; furthermore, the installation of a PCR can be difficult and costly, especially in places with hard accessibility. Active reflectors (AR) represent a less cumbersome alternative to PCRs, while still providing a stable phase response. This paper describes the design, implementation, and test of an AR prototype, designed to operate with the Sentinel-1 synthetic aperture radar (SAR), aimed at providing a fair performance/cost benefit. These characteristics, obtained through a tradeoff between the use of off-the-shelf components and a simple architecture, can make the setup of a dense network (i.e., tens of devices) in the monitored areas feasible. The paper reports the design, implementation, and the analysis of different tests carried out in a laboratory, and in a real condition in the field, to illustrate AR reliability and estimate its phase stability.
Collapse
|
14
|
Forward and Backward Unidirectional Scattering by the Core-Shell Nanocube Dimer with Balanced Gain and Loss. NANOMATERIALS 2020; 10:nano10081440. [PMID: 32718062 PMCID: PMC7466381 DOI: 10.3390/nano10081440] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/25/2020] [Revised: 07/13/2020] [Accepted: 07/16/2020] [Indexed: 11/16/2022]
Abstract
An optical nanoantenna consisting of a Au-dielectric core-shell nanocube dimer with switchable directionality was designed and described. Our theoretical model and numerical simulation showed that switching between forward and backward directions can be achieved with balanced gain and loss, using a single element by changing the coefficient κ in the core, which can be defined by the relative phase of the polarizability. The optical response indicated a remarkable dependence on the coefficient κ in the core as well as frequency. The location of the electric field enhancement was specified by the different coefficient κ and, furthermore, the chained optical nanoantenna and coupled electric dipole emitted to the optical nanoantenna played significant roles in unidirectional scattering. This simple method to calculate the feasibility of unidirectional and switchable scattering provides an effective strategy to explore the functionalities of nanophotonic devices.
Collapse
|
15
|
Combined Use of Sentinel-1 SAR and Landsat Sensors Products for Residual Soil Moisture Retrieval over Agricultural Fields in the Upper Blue Nile Basin, Ethiopia. SENSORS 2020; 20:s20113282. [PMID: 32526894 PMCID: PMC7309137 DOI: 10.3390/s20113282] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/26/2020] [Revised: 06/03/2020] [Accepted: 06/05/2020] [Indexed: 11/17/2022]
Abstract
The objective of this paper is to investigate the potential of sentinel-1 SAR sensor products and the contribution of soil roughness parameters to estimate volumetric residual soil moisture (RSM) in the Upper Blue Nile (UBN) basin, Ethiopia. The backscatter contribution of crop residue water content was estimated using Landsat sensor product and the water cloud model (WCM). The surface roughness parameters were estimated from the Oh and Baghdadi models. A feed-forward artificial neural network (ANN) method was tested for its potential to translate SAR backscattering and surface roughness input variables to RSM values. The model was trained for three inversion configurations: (i) SAR backscattering from vertical transmit and vertical receive (SAR VV) polarization only; (ii) using SAR VV and the standard deviation of surface heights (hrms), and (iii) SAR VV, hrms, and optimal surface correlation length (leff). Field-measured volumetric RSM data were used to train and validate the method. The results showed that the ANN soil moisture estimation model performed reasonably well for the estimation of RSM using the single input variable of SAR VV data only. The ANN prediction accuracy was slightly improved when SAR VV and the surface roughness parameters (hrms and leff) were incorporated into the prediction model. Consequently, the ANN’s prediction accuracy with root mean square error (RMSE) = 0.035 cm3/cm3, mean absolute error (MAE) = 0.026 cm3/cm3, and r = 0.73 was achieved using the third inversion configuration. The result implies the potential of Sentinel-1 SAR data to accurately retrieve RSM content over an agricultural site covered by stubbles. The soil roughness parameters are also potentially an important variable to soil moisture estimation using SAR data although their contribution to the accuracy of RSM prediction is slight in this study. In addition, the result highlights the importance of combining Sentinel-1 SAR and Landsat images based on an ANN approach for improving RSM content estimations over crop residue areas.
Collapse
|
16
|
Subdiffuse scattering model for single fiber reflectance spectroscopy. JOURNAL OF BIOMEDICAL OPTICS 2020; 25:1-11. [PMID: 31920047 PMCID: PMC7008500 DOI: 10.1117/1.jbo.25.1.015001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/24/2019] [Accepted: 12/03/2019] [Indexed: 05/08/2023]
Abstract
To detect small-scale changes in tissue with optical techniques, small sampling volumes are required. Single fiber reflectance (SFR) spectroscopy has a sampling depth of a few hundred micrometers. SFR spectroscopy uses a single fiber to emit and collect light. The only available model to determine optical properties with SFR spectroscopy was derived for tissues with modified Henyey-Greenstein phase functions. Previously, we demonstrated that this model is inadequate for other tissue phase functions. We develop a model to relate SFR measurements to scattering properties for a range of phase functions, in the absence of absorption. Since the source and detector overlap, the reflectance cannot be accurately described by diffusion theory alone: SFR measurements are subdiffuse. Therefore, we describe the reflectance as a combination of a diffuse and a semiballistic component. We use the model of Farrell et al. for the diffuse component, solved for an overlapping source and detector fiber. For the semiballistic component, we derive a new parameter, psb, which incorporates the integrals of the phase function over 1 deg in the backward direction and 23 deg in the forward direction. Our model predicts the reflectance with a median error of 2.1%, compared to 9.0% for the currently available model.
Collapse
|
17
|
A proof that multiple waves propagate in ensemble-averaged particulate materials. Proc Math Phys Eng Sci 2019; 475:20190344. [PMID: 31611729 PMCID: PMC6784390 DOI: 10.1098/rspa.2019.0344] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2019] [Accepted: 08/14/2019] [Indexed: 11/12/2022] Open
Abstract
Effective medium theory aims to describe a complex inhomogeneous material in terms of a few important macroscopic parameters. To characterize wave propagation through an inhomogeneous material, the most crucial parameter is the effective wavenumber. For this reason, there are many published studies on how to calculate a single effective wavenumber. Here, we present a proof that there does not exist a unique effective wavenumber; instead, there are an infinite number of such (complex) wavenumbers. We show that in most parameter regimes only a small number of these effective wavenumbers make a significant contribution to the wave field. However, to accurately calculate the reflection and transmission coefficients, a large number of the (highly attenuating) effective waves is required. For clarity, we present results for scalar (acoustic) waves for a two-dimensional material filled (over a half-space) with randomly distributed circular cylindrical inclusions. We calculate the effective medium by ensemble averaging over all possible inhomogeneities. The proof is based on the application of the Wiener-Hopf technique and makes no assumption on the wavelength, particle boundary conditions/size or volume fraction. This technique provides a simple formula for the reflection coefficient, which can be explicitly evaluated for monopole scatterers. We compare results with an alternative numerical matching method.
Collapse
|
18
|
General model for depth-resolved estimation of the optical attenuation coefficients in optical coherence tomography. JOURNAL OF BIOPHOTONICS 2019; 12:e201800402. [PMID: 31012263 DOI: 10.1002/jbio.201800402] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/26/2018] [Revised: 04/19/2019] [Accepted: 04/22/2019] [Indexed: 05/22/2023]
Abstract
We present the proof of concept of a general model that uses the tissue sample transmittance as input to estimate the depth-resolved attenuation coefficient of tissue samples using optical coherence tomography (OCT). This method allows us to obtain an image of tissue optical properties instead of intensity contrast, guiding diagnosis and tissues differentiation, extending its application from thick to thin samples. The performance of our method was simulated and tested with the assistance of a home built single-layered and multilayered phantoms (~100 μm each layer) with known attenuation coefficient on the range of 0.9 to 2.32 mm-1 . It is shown that the estimated depth-resolved attenuation coefficient recovers the reference values, measured by using an integrating sphere followed by the inverse adding doubling processing technique. That was corroborated for all situations when the correct transmittance value is used with an average difference of 7%. Finally, we applied the proposed method to estimate the depth-resolved attenuation coefficient for a thin biological sample, demonstrating the ability of our method on real OCT images.
Collapse
|
19
|
Radio Frequency Identification and Sensing Techniques and Their Applications-A Review of the State-of-the-Art. SENSORS 2019; 19:s19184012. [PMID: 31533321 PMCID: PMC6766906 DOI: 10.3390/s19184012] [Citation(s) in RCA: 55] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/17/2019] [Revised: 08/27/2019] [Accepted: 09/13/2019] [Indexed: 11/25/2022]
Abstract
Radio Frequency Identification (RFID) sensors, integrating the features of Wireless Information and Power Transfer (WIPT), object identification and energy efficient sensing capabilities, have been considered a new paradigm of sensing and communication for the futuristic information systems. RFID sensor tags featuring contactless sensing, wireless information transfer, wireless powered, light weight, non-line-of-sight transmission, flexible and pasteable are a critical enabling technology for future Internet-of-Things (IoT) applications, such as manufacturing, logistics, healthcare, agriculture and food. They have attracted numerous research efforts due to their innovative potential in the various application fields. However, there has been a gap between the in-lab investigations and the practical IoT application scenarios, which has motivated this survey of this research to identify the promising enabling techniques and the underlying challenges. This study aims to provide an exhaustive review on the state-of-art RFID sensor technologies from the system implementation perspective by focusing on the fundamental RF energy harvesting theories, the recent technical progresses and commercial solutions, innovative applications and some RFID sensor based IoT solutions, identify the underlying technological challenges at the time being, and give the future research trends and promising application fields in the rich sensing applications of the forthcoming IoT era.
Collapse
|
20
|
High-pressure nuclear inelastic scattering with backscattering monochromatization. JOURNAL OF SYNCHROTRON RADIATION 2019; 26:1592-1599. [PMID: 31490149 DOI: 10.1107/s1600577519008853] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/15/2018] [Accepted: 06/21/2019] [Indexed: 06/10/2023]
Abstract
The capability to perform high-pressure low-temperature nuclear inelastic scattering on 125Te and 121Sb with a sapphire backscattering monochromator is presented. This technique was applied to measure nuclear inelastic scattering in TeO2 at pressures up to 10 GPa and temperatures down to 25 K. The evaluated partial Te densities of phonon states were compared with theoretical calculations and with Raman scattering measured under the same conditions. The high-pressure cell developed in this work can also be used for other techniques at pressures up to at least 100 GPa.
Collapse
|
21
|
High-Index Glass Ball Retroreflectors for Measuring Lateral Positions. SENSORS 2019; 19:s19051082. [PMID: 30832424 PMCID: PMC6427531 DOI: 10.3390/s19051082] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/25/2019] [Revised: 02/17/2019] [Accepted: 02/27/2019] [Indexed: 11/16/2022]
Abstract
This paper is concerned with backscattered luminous signals, coming from a particular class of dielectric spheres illuminated by a coherent source. The purpose is to measure the lateral position of the sphere serving as an optical target, to achieve an overall contactless sensor of lateral position in space. Traditional approaches and theories such as ray-tracing and Mie scattering—as implemented in dedicated software—are applied to investigate their fitness for purpose in this application. No previous literature was found dealing with this specific case. Unfortunately, our observations did not match the theories’ predictions to an acceptable degree, and these approaches proved to be unsatisfactory. The rest of the paper focusses then on the development and comparison of suitable algorithms to compute the image coordinates of a representative point, which was in fact the true motivation of this work. Two original algorithms are proposed and discussed. Their robustness and repeatability are benchmarked under noisy conditions and at different distances from the target, with simulated as well as real images. Both resulted capable of sub-pixel accuracy.
Collapse
|
22
|
Investigation on the Influence of Humidity on Stimulated Brillouin Backscattering in Perfluorinated Polymer Optical Fibers. SENSORS 2018; 18:s18113952. [PMID: 30445689 PMCID: PMC6263901 DOI: 10.3390/s18113952] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/26/2018] [Revised: 11/09/2018] [Accepted: 11/09/2018] [Indexed: 11/23/2022]
Abstract
In this paper perfluorinated graded-index polymer optical fibers are characterized with respect to the influence of relative humidity changes on spectral transmission absorption and Rayleigh backscattering. The hygroscopic and thermal expansion coefficient of the fiber are determined to be CHE = (7.4 ± 0.1) ·10−6 %r.h.−1 and CTE = (22.7 ± 0.3) ·10−6 K−1, respectively. The influence of humidity on the Brillouin backscattering power and linewidth are presented for the first time to our knowledge. The Brillouin backscattering power at a pump wavelength of 1319 nm is affected by temperature and humidity. The Brillouin linewidth is observed to be a function of temperature but not of humidity. The strain coefficient of the BFS is determined to be CS= (−146.5 ± 0.9) MHz/% for a wavelength of 1319 nm within a strain range from 0.1% to 1.5%. The obtained results demonstrate that the humidity-induced Brillouin frequency shift is predominantly caused by the swelling of the fiber over-cladding that leads to fiber straining.
Collapse
|
23
|
Plasmonic Effect of Gold Nanostars in Highly Efficient Organic and Perovskite Solar Cells. ACS APPLIED MATERIALS & INTERFACES 2017; 9:36111-36118. [PMID: 28937203 DOI: 10.1021/acsami.7b11084] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Herein, a novel strategy is presented for enhancing light absorption by incorporating gold nanostars (Au NSs) into both the active layer of organic solar cells (OSCs) and the rear-contact hole transport layer of perovskite solar cells (PSCs). We demonstrate that the power conversion efficiencies of OSCs and PSCs with embedded Au NSs are improved by 6 and 14%, respectively. We find that pegylated Au NSs are greatly dispersable in a chlorobenzene solvent, which enabled complete blending of Au NSs with the active layer. The plasmonic contributions and accelerated charge transfer are believed to improve the short-circuit current density and the fill factor. This study demonstrates the roles of plasmonic nanoparticles in the improved optical absorption, where the improvement in OSCs was attributed to surface plasmon resonance (SPR) and in PSCs was attributed to both SPR and the backscattering effect. Additionally, devices including Au NSs exhibited a better charge separation/transfer, reduced charge recombination rate, and efficient charge transport. This work provides a comprehensive understanding of the roles of plasmonic Au NS particles in OSCs and PSCs, including an insightful approach for the further development of high-performance optoelectronic devices.
Collapse
|
24
|
Abstract
In this paper, we propose a model-based scattering removal method for stereo vision for robot manipulation in indoor scattering media where the commonly used ranging sensors are unable to work. Stereo vision is an inherently ill-posed and challenging problem. It is even more difficult in the case of images of dense fog or dense steam scenes illuminated by active light sources. Images taken in such environments suffer attenuation of object radiance and scattering of the active light sources. To solve this problem, we first derive the imaging model for images taken in a dense scattering medium with a single active illumination close to the cameras. Based on this physical model, the non-uniform backscattering signal is efficiently removed. The descattered images are then utilized as the input images of stereo vision. The performance of the method is evaluated based on the quality of the depth map from stereo vision. We also demonstrate the effectiveness of the proposed method by carrying out the real robot manipulation task.
Collapse
|
25
|
COSMO-SkyMed Image Investigation of Snow Features in Alpine Environment. SENSORS 2017; 17:s17010084. [PMID: 28054962 PMCID: PMC5298657 DOI: 10.3390/s17010084] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/12/2016] [Revised: 12/20/2016] [Accepted: 12/27/2016] [Indexed: 11/16/2022]
Abstract
In this work, X band images acquired by COSMO-SkyMed (CSK) on alpine environment have been analyzed for investigating snow characteristics and their effect on backscattering variations. Preliminary results confirmed the capability of simultaneous optical and Synthetic Aperture Radar (SAR) images (Landsat-8 and CSK) in separating snow/no-snow areas and in detecting wet snow. The sensitivity of backscattering to snow depth has not always been confirmed, depending on snow characteristics related to the season. A model based on Dense Media Radiative Transfer theory (DMRT-QMS) was applied for simulating the backscattering response on the X band from snow cover in different conditions of grain size, snow density and depth. By using DMRT-QMS and snow in-situ data collected on Cordevole basin in Italian Alps, the effect of grain size and snow density, beside snow depth and snow water equivalent, was pointed out, showing that the snow features affect the backscatter in different and sometimes opposite ways. Experimental values of backscattering were correctly simulated by using this model and selected intervals of ground parameters. The relationship between simulated and measured backscattering for the entire dataset shows slope >0.9, determination coefficient, R2 = 0.77, and root mean square error, RMSE = 1.1 dB, with p-value <0.05.
Collapse
|
26
|
Enhancing the sensitivity of mesoscopic light reflection statistics in weakly disordered media by interface reflections. INTERNATIONAL JOURNAL OF MODERN PHYSICS. B 2016; 30:1650155. [PMID: 29307948 PMCID: PMC5754019 DOI: 10.1142/s0217979216501551] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Reflection statistics have not been well studied for optical random media whose mean refractive indices do not match with the refractive indices of their surrounding media. Here, we theoretically study how this refractive index mismatch between a one-dimensional (1D) optical sample and its surrounding medium affects the reflection statistics in the weak disorder limit, when the fluctuation part of the refractive index (Δn) is much smaller than the mismatch as well as the mean refractive index of the sample (Δn ≪ 〈n〉). In the theoretical derivation, we perform a detailed calculation that results in the analytical forms of the mean and standard deviation (STD) of the reflection coefficient in terms of disorder parameters ( [Formula: see text] and its correlation length lc ) in an index mismatched backscattering system. Particularly, the orders of disorder parameters in STD of the reflection coefficient for index mismatched systems are shown to be lower (~(〈Δn2〉lc )1/2) than that of the matched systems (~〈Δn2〉lc ). By comparing STDs of the reflection coefficient values of index matched and mismatched systems, we show that reflection coefficient at the sample boundaries in index mismatched systems can enhance the signal of the STD to the "disorder parameters" of the reflection coefficient. In terms of biophotonics applications, this result can lead to potential techniques that effectively extract the sample disorder parameters by manipulating the index mismatched conditions. Potential applications of the technique for enhancement in sensitivity of cancer detection at the single cell level are also discussed.
Collapse
|
27
|
Diffuse optical microscopy for quantification of depth-dependent epithelial backscattering in the cervix. JOURNAL OF BIOMEDICAL OPTICS 2016; 21:66001. [PMID: 27251077 PMCID: PMC8357336 DOI: 10.1117/1.jbo.21.6.066001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/23/2016] [Accepted: 05/02/2016] [Indexed: 05/21/2023]
Abstract
A fiber optic imaging approach is presented using structured illumination for quantification of almost pure epithelial backscattering. We employ multiple spatially modulated projection patterns and camera-based reflectance capture to image depth-dependent epithelial scattering. The potential diagnostic value of our approach is investigated on cervical ex vivo tissue specimens. Our study indicates a strong backscattering increase in the upper part of the cervical epithelium caused by dysplastic microstructural changes. Quantization of relative depth-dependent backscattering is confirmed as a potentially useful diagnostic feature for detection of precancerous lesions in cervical squamous epithelium.
Collapse
|
28
|
Reconstruction of explicit structural properties at the nanoscale via spectroscopic microscopy. JOURNAL OF BIOMEDICAL OPTICS 2016; 21:25007. [PMID: 26886803 PMCID: PMC4756051 DOI: 10.1117/1.jbo.21.2.025007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/11/2015] [Accepted: 01/14/2016] [Indexed: 05/03/2023]
Abstract
The spectrum registered by a reflected-light bright-field spectroscopic microscope (SM) can quantify the microscopically indiscernible, deeply subdiffractional length scales within samples such as biological cells and tissues. Nevertheless, quantification of biological specimens via any optical measures most often reveals ambiguous information about the specific structural properties within the studied samples. Thus, optical quantification remains nonintuitive to users from the diverse fields of technique application. In this work, we demonstrate that the SM signal can be analyzed to reconstruct explicit physical measures of internal structure within label-free, weakly scattering samples: characteristic length scale and the amplitude of spatial refractive-index (RI) fluctuations. We present and validate the reconstruction algorithm via finite-difference time-domain solutions of Maxwell's equations on an example of exponential spatial correlation of RI. We apply the validated algorithm to experimentally measure structural properties within isolated cells from two genetic variants of HT29 colon cancer cell line as well as within a prostate tissue biopsy section. The presented methodology can lead to the development of novel biophotonics techniques that create two-dimensional maps of explicit structural properties within biomaterials: the characteristic size of macromolecular complexes and the variance of local mass density.
Collapse
|
29
|
Artifact reduction of ultrasound Nakagami imaging by combining multifocus image reconstruction and the noise-assisted correlation algorithm. ULTRASONIC IMAGING 2015; 37:53-69. [PMID: 24626567 DOI: 10.1177/0161734614526379] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Several studies have investigated Nakagami imaging to complement the B-scan in tissue characterization. The noise-induced artifact and the parameter ambiguity effect can affect performance of Nakagami imaging in the detection of variations in scatterer concentration. This study combined multifocus image reconstruction and the noise-assisted correlation algorithm (NCA) into the algorithm of Nakagami imaging to suppress the artifacts. A single-element imaging system equipped with a 5 MHz transducer was used to perform the brightness/depth (B/D) scanning of agar phantoms with scatterer concentrations ranging from 2 to 32 scatterers/mm(3). Experiments were also carried out on a mass with some strong point reflectors in a breast phantom using a commercial scanner with a 7.5 MHz linear array transducer operated at multifocus mode. The multifocus radiofrequency (RF) signals after the NCA process were used for Nakagami imaging. In the experiments on agar phantoms, an increasing scatterer concentration from 2 to 32 scatterers/mm(3) led to backscattered statistics ranging from pre-Rayleigh to Rayleigh distributions, corresponding to the increase in the Nakagami parameter measured in the focal zone from 0.1 to 0.8. However, the artifacts in the far field resulted in the Nakagami parameters of various scatterer concentrations to be close to 1 (Rayleigh distribution), making Nakagami imaging difficult to characterize scatterers. In the same scatterer concentration range, multifocus Nakagami imaging with the NCA simultaneously suppressed two types of artifacts, making the Nakagami parameter increase from 0.1 to 0.8 in the focal zone and from 0.18 to 0.7 in the far field, respectively. In the breast phantom experiments, the backscattered statistics of the mass corresponded to a high degree of pre-Rayleigh distribution. The Nakagami parameter of the mass before and after artifact reduction was 0.7 and 0.37, respectively. The results demonstrated that the proposed method for artifact reduction allows a sensitive and effective scatterer characterization by Nakagami imaging.
Collapse
|
30
|
Scattering anisotropy-weighted mesoscopic imaging. JOURNAL OF BIOMEDICAL OPTICS 2012; 17:90501-1. [PMID: 23085898 PMCID: PMC3434765 DOI: 10.1117/1.jbo.17.9.090501] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
We report that when tissue images are formed via a small solid angle in the backward direction (i.e., back-directional gating), the image intensity is dominantly determined by tissue scattering anisotropy. Thus, this configuration allows for scattering anisotropy-weighted imaging that can provide an intrinsic contrast by capturing tissue structures and organizations. To demonstrate the immediate feasibility, we apply scattering anisotropy-weighted imaging to tissue blocks including basal-cell carcinomas as a pilot study. The main feature of our imaging approach is the high sensitivity to tumor locations and the simplicity for large-area visualization. We further envision that scattering anisotropy-weighted imaging could potentially be used to visualize tissue microenvironments in a mesoscopic (between microscopic and macroscopic) imaging setting.
Collapse
|
31
|
Characterization and three-dimensional localization of cancerous prostate tissue using backscattering scanning polarization imaging and independent component analysis. JOURNAL OF BIOMEDICAL OPTICS 2012; 17:081419. [PMID: 23224180 PMCID: PMC3602815 DOI: 10.1117/1.jbo.17.8.081419] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2011] [Revised: 07/15/2012] [Accepted: 07/17/2012] [Indexed: 05/23/2023]
Abstract
Characterization and three-dimensional (3-D) localization of human cancerous prostate tissue embedded in normal prostate tissue were demonstrated using backscattering scanning polarization imaging and an inverse imaging reconstruction algorithm, optical tomography using independent component analysis (OPTICA). Two-dimensional (2-D) backscattering images of a prostate tissue sample illuminated with a scanning laser beam were measured with a CCD camera to obtain multiple angular views of the target embedded inside the tissue. The recorded sets of 2-D images were used to determine the existence and 3-D location of the cancerous prostate tissue using the algorithm. The difficulty arises in the backscattering geometry because the profile of the incident beam and the surface property of the tissue sample appreciably affect the spatial distribution of the backscattered light. This challenge was addressed by: (1) synthesizing a "clean" background image of the host medium; and (2) numerically marching the propagation of the scattered light from the hidden target to the surface of the tissue sample until matching the retrieved independent component. The OPTICA algorithm was improved specifically for the backscattering model, and used to obtain 3-D locations of the cancerous tissue embedded in normal host tissue. The retrieved results were found in good agreement with the known 3-D positions of the cancerous tissue.
Collapse
|
32
|
Wavelength-dependent backscattering measurements for quantitative monitoring of apoptosis, part 2: early spectral changes during apoptosis are linked to apoptotic volume decrease. JOURNAL OF BIOMEDICAL OPTICS 2011; 16:117002. [PMID: 22112134 PMCID: PMC3221718 DOI: 10.1117/1.3644911] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/25/2011] [Revised: 09/05/2011] [Accepted: 09/08/2011] [Indexed: 05/18/2023]
Abstract
Elastic scattering spectroscopy (ESS), in the form of wavelength-dependent backscattering measurements, can be used to monitor apoptosis in cell cultures. Early changes in backscattering upon apoptosis induction are characterized by an overall decrease in spectral slope and begin as early as 10 to 15 min post-treatment, progressing over the next 6 to 8 h. The timescale of early scattering changes is consistent with reports of the onset of apoptotic volume decrease (AVD). Modeling cellular scattering with a fixed distribution of sizes and a decreasing index ratio, as well as an increased contribution of the whole cell to cellular scattering, resulting from increased cytoplasmic density, is also consistent with observed spectral changes. Changes in ESS signal from cells undergoing osmotically-induced volume decrease in the absence of apoptosis were similar, but smaller in magnitude, to those of apoptotic cells. Further, blockage of Cl(-) channels, which blocks AVD and delays apoptosis, blocked the early scattering changes, indicating that the early scattering changes during apoptosis result, at least partially, from AVD. Work continues to identify the additional sources of early spectral scattering changes that result from apoptosis induction.
Collapse
|
33
|
Wavelength-dependent backscattering measurements for quantitative monitoring of apoptosis, part 1: early and late spectral changes are indicative of the presence of apoptosis in cell cultures. JOURNAL OF BIOMEDICAL OPTICS 2011; 16:117001. [PMID: 22112133 PMCID: PMC3221717 DOI: 10.1117/1.3644389] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/25/2011] [Revised: 09/05/2011] [Accepted: 09/08/2011] [Indexed: 05/23/2023]
Abstract
Apoptosis, a form of programmed cell death with unique morphological and biochemical features, is dysregulated in cancer and is activated by many cancer chemotherapeutic drugs. Noninvasive assays for apoptosis in cell cultures can aid in screening of new anticancer agents. We have previously demonstrated that elastic scattering spectroscopy can monitor apoptosis in cell cultures. In this report we present data on monitoring the detailed time-course of scattering changes in a Chinese hamster ovary (CHO) and PC-3 prostate cancer cells treated with staurosporine to induce apoptosis. Changes in the backscattering spectrum are detectable within 10 min, and continue to progress up to 48 h after staurosporine treatment, with the magnitude and kinetics of scattering changes dependent on inducer concentration. Similar responses were observed in CHO cells treated with several other apoptosis-inducing protocols. Early and late scattering changes were observed under conditions shown to induce apoptosis via caspase activity assay and were absent under conditions where apoptosis was not induced. Finally, blocking caspase activity and downstream apoptotic morphology changes prevented late scattering changes. These observations demonstrate that early and late changes in wavelength-dependent backscattering correlate with the presence of apoptosis in cell cultures and that the late changes are specific to apoptosis.
Collapse
|
34
|
Abstract
Retinal oximetry offers potential for noninvasive assessment of central venous oxyhemoglobin saturation (SO(2)) via the retinal vessels but requires a calibrated accuracy of ±3% saturation in order to be clinically useful. Prior oximeter designs have been hampered by poor saturation calibration accuracy. We demonstrate that the blue-green oximetry (BGO) technique can provide accuracy within ±3% in swine when multiply scattered light from blood within a retinal vessel is isolated. A noninvasive on-axis scanning retinal oximeter (ROx-3) is constructed that generates a multiwavelength image in the range required for BGO. A field stop in the detection pathway is used in conjunction with an anticonfocal bisecting wire to remove specular vessel reflections and isolate multiply backscattered light from the blood column within a retinal vessel. This design is tested on an enucleated swine eye vessel and a retinal vein in a human volunteer with retinal SO(2) measurements of ∼1 and ∼65%, respectively. These saturations, calculated using the calibration line from earlier work, are internally consistent with a standard error of the mean of ±2% SO(2). The absolute measures are well within the expected saturation range for the site (-1 and 63%). This is the first demonstration of noninvasive on-axis BGO retinal oximetry.
Collapse
|
35
|
A Fully-Passive Wireless Microsystem for Recording of Neuropotentials using RF Backscattering Methods. JOURNAL OF MICROELECTROMECHANICAL SYSTEMS : A JOINT IEEE AND ASME PUBLICATION ON MICROSTRUCTURES, MICROACTUATORS, MICROSENSORS, AND MICROSYSTEMS 2011; 20:1119-1130. [PMID: 22267898 PMCID: PMC3259707 DOI: 10.1109/jmems.2011.2162487] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
The ability to safely monitor neuropotentials is essential in establishing methods to study the brain. Current research focuses on the wireless telemetry aspect of implantable sensors in order to make these devices ubiquitous and safe. Chronic implants necessitate superior reliability and durability of the integrated electronics. The power consumption of implanted electronics must also be limited to within several milliwatts to microwatts to minimize heat trauma in the human body. In order to address these severe requirements, we developed an entirely passive and wireless microsystem for recording neuropotentials. An external interrogator supplies a fundamental microwave carrier to the microsystem. The microsystem comprises varactors that perform nonlinear mixing of neuropotential and fundamental carrier signals. The varactors generate third-order mixing products that are wirelessly backscattered to the external interrogator where the original neuropotential signals are recovered. Performance of the neuro-recording microsystem was demonstrated by wireless recording of emulated and in vivo neuropotentials. The obtained results were wireless recovery of neuropotentials as low as approximately 500 microvolts peak-to-peak (μV(pp)) with a bandwidth of 10 Hz to 3 kHz (for emulated signals) and with 128 epoch signal averaging of repetitive signals (for in vivo signals).
Collapse
|
36
|
Milli-electronvolt monochromatization of hard X-rays with a sapphire backscattering monochromator. JOURNAL OF SYNCHROTRON RADIATION 2011; 18:802-810. [PMID: 21862862 PMCID: PMC3258116 DOI: 10.1107/s090904951102485x] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/29/2010] [Accepted: 06/24/2011] [Indexed: 05/31/2023]
Abstract
A sapphire backscattering monochromator with 1.1 (1) meV bandwidth for hard X-rays (20-40 keV) is reported. The optical quality of several sapphire crystals has been studied and the best crystal was chosen to work as the monochromator. The small energy bandwidth has been obtained by decreasing the crystal volume impinged upon by the beam and by choosing the crystal part with the best quality. The monochromator was tested at the energies of the nuclear resonances of (121)Sb at 37.13 keV, (125)Te at 35.49 keV, (119)Sn at 23.88 keV, (149)Sm at 22.50 keV and (151)Eu at 21.54 keV. For each energy, specific reflections with sapphire temperatures in the 150-300 K region were chosen. Applications to nuclear inelastic scattering with these isotopes are demonstrated.
Collapse
|
37
|
Multiple scattering model for the penetration depth of low-coherence enhanced backscattering. JOURNAL OF BIOMEDICAL OPTICS 2011; 16:097006. [PMID: 21950941 PMCID: PMC3188644 DOI: 10.1117/1.3625402] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2011] [Revised: 07/20/2011] [Accepted: 07/21/2011] [Indexed: 05/24/2023]
Abstract
Low-coherence enhanced backscattering (LEBS) is a depth-selective self-interference phenomenon that originates from light traveling time-reversed paths in a scattering medium. The depth selectivity of LEBS and its sensitivity to optical properties of the scattering medium has made it a promising technique for probing the structure of biological tissue with applications to disease diagnosis and, in particular, precancerous conditions. The ability to accurately predict the penetration depth of the LEBS signal is important in targeting an optimal tissue depth for detecting precancerous cells. This prediction is further complicated by the variation in optical properties of different tissue types. In this paper, the effects of the reduced scattering coefficient (μ(s)'), the phase function and the instrument spatial coherence length (L(sc)) on the LEBS penetration depth are quantified. It is determined that the LEBS penetration depth is primarily dependent on L(sc), μ(s)', and the anisotropy factor (g), but has minimal dependence on higher moments of the phase function. An empirical expression, having a similar form as the double scattering approximation for LEBS, is found to accurately predict the average penetration depth in the multiple scattering regime. The expression is shown to be accurate for a broad range of experimentally relevant optical properties and spatial coherence lengths.
Collapse
|
38
|
Measurement of optical scattering properties with low-coherence enhanced backscattering spectroscopy. JOURNAL OF BIOMEDICAL OPTICS 2011; 16:067007. [PMID: 21721828 PMCID: PMC3138801 DOI: 10.1117/1.3589349] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Low-coherence enhanced backscattering (LEBS) is a depth selective technique that allows noninvasive characterization of turbid media such as biological tissue. LEBS provides a spectral measurement of the tissue reflectance distribution as a function of distance between incident and reflected ray pairs through the use of partial spatial coherence broadband illumination. We present LEBS as a new depth-selective technique to measure optical properties of tissue in situ. Because LEBS enables measurements of reflectance due to initial scattering events, LEBS is sensitive to the shape of the phase function in addition to the reduced scattering coefficient (μ(s) (*)). We introduce a simulation of LEBS that implements a two parameter phase function based on the Whittle-Matérn refractive index correlation function model. We show that the LEBS enhancement factor (E) primarily depends on μ(s) (*), the normalized spectral dependence of E (S(n)) depends on one of the two parameters of the phase function that also defines the functional type of the refractive index correlation function (m), and the LEBS peak width depends on both the anisotropy factor (g) and m. Three inverse models for calculating these optical properties are described and the calculations are validated with an experimental measurement from a tissue phantom.
Collapse
|
39
|
Automated classification of breast pathology using local measures of broadband reflectance. JOURNAL OF BIOMEDICAL OPTICS 2010; 15:066019. [PMID: 21198193 PMCID: PMC3032233 DOI: 10.1117/1.3516594] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
We demonstrate that morphological features pertinent to a tissue's pathology may be ascertained from localized measures of broadband reflectance, with a mesoscopic resolution (100-μm lateral spot size) that permits scanning of an entire margin for residual disease. The technical aspects and optimization of a k-nearest neighbor classifier for automated diagnosis of pathologies are presented, and its efficacy is validated in 29 breast tissue specimens. When discriminating between benign and malignant pathologies, a sensitivity and specificity of 91 and 77% was achieved. Furthermore, detailed subtissue-type analysis was performed to consider how diverse pathologies influence scattering response and overall classification efficacy. The increased sensitivity of this technique may render it useful to guide the surgeon or pathologist where to sample pathology for microscopic assessment.
Collapse
|
40
|
Scanning elastic scattering spectroscopy detects metastatic breast cancer in sentinel lymph nodes. JOURNAL OF BIOMEDICAL OPTICS 2010; 15:047001. [PMID: 20799832 PMCID: PMC2917446 DOI: 10.1117/1.3463005] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
A novel method for rapidly detecting metastatic breast cancer within excised sentinel lymph node(s) of the axilla is presented. Elastic scattering spectroscopy (ESS) is a point-contact technique that collects broadband optical spectra sensitive to absorption and scattering within the tissue. A statistical discrimination algorithm was generated from a training set of nearly 3000 clinical spectra and used to test clinical spectra collected from an independent set of nodes. Freshly excised nodes were bivalved and mounted under a fiber-optic plate. Stepper motors raster-scanned a fiber-optic probe over the plate to interrogate the node's cut surface, creating a 20x20 grid of spectra. These spectra were analyzed to create a map of cancer risk across the node surface. Rules were developed to convert these maps to a prediction for the presence of cancer in the node. Using these analyses, a leave-one-out cross-validation to optimize discrimination parameters on 128 scanned nodes gave a sensitivity of 69% for detection of clinically relevant metastases (71% for macrometastases) and a specificity of 96%, comparable to literature results for touch imprint cytology, a standard technique for intraoperative diagnosis. ESS has the advantage of not requiring a pathologist to review the tissue sample.
Collapse
|
41
|
DAVE: A Comprehensive Software Suite for the Reduction, Visualization, and Analysis of Low Energy Neutron Spectroscopic Data. JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY 2009; 114:341-58. [PMID: 27504233 PMCID: PMC4646530 DOI: 10.6028/jres.114.025] [Citation(s) in RCA: 456] [Impact Index Per Article: 30.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 10/16/2009] [Indexed: 05/18/2023]
Abstract
National user facilities such as the NIST Center for Neutron Research (NCNR) require a significant base of software to treat the data produced by their specialized measurement instruments. There is no universally accepted and used data treatment package for the reduction, visualization, and analysis of inelastic neutron scattering data. However, we believe that the software development approach adopted at the NCNR has some key characteristics that have resulted in a successful software package called DAVE (the Data Analysis and Visualization Environment). It is developed using a high level scientific programming language, and it has been widely adopted in the United States and abroad. In this paper we describe the development approach, elements of the DAVE software suite, its usage and impact, and future directions and opportunities for development.
Collapse
|
42
|
Wavelength-dependent backscattering measurements for quantitative real-time monitoring of apoptosis in living cells. JOURNAL OF BIOMEDICAL OPTICS 2009; 14:064013. [PMID: 20059251 PMCID: PMC2794414 DOI: 10.1117/1.3259363] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/13/2009] [Revised: 09/16/2009] [Accepted: 09/16/2009] [Indexed: 05/18/2023]
Abstract
Apoptosis--programmed cell death--is a cellular process exhibiting distinct biochemical and morphological changes. An understanding of the early morphological changes that a cell undergoes during apoptosis can provide the opportunity to monitor apoptosis in tissue, yielding diagnostic and prognostic information. There is avid interest regarding the involvement of apoptosis in cancer. The initial response of a tumor to successful cancer treatment is often massive apoptosis. Current apoptosis detection methods require cell culture disruption. Our aim is to develop a nondisruptive optical method to monitor apoptosis in living cells and tissues. This would allow for real-time evaluation of apoptotic progression of the same cell culture over time without alteration. Elastic scattering spectroscopy (ESS) is used to monitor changes in light-scattering properties of cells in vitro due to apoptotic morphology changes. We develop a simple instrument capable of wavelength-resolved ESS measurements from cell cultures in the backward direction. Using Mie theory, we also develop an algorithm that extracts the size distribution of scatterers in the sample. The instrument and algorithm are validated with microsphere suspensions. For cell studies, Chinese hamster ovary (CHO) cells are cultured to confluence on plates and are rendered apoptotic with staurosporine. Backscattering measurements are performed on pairs of treated and control samples at a sequence of times up to 6-h post-treatment. Initial results indicate that ESS is capable of discriminating between treated and control samples as early as 10- to 15-min post-treatment, much earlier than is sensed by standard assays for apoptosis. Extracted size distributions from treated and control samples show a decrease in Rayleigh and 150-nm scatterers, relative to control samples, with a corresponding increase in 200-nm particles. Work continues to correlate these size distributions with underlying morphology. To our knowledge, this is the first report of the use of backscattering spectral measurements to quantitatively monitor apoptosis in viable cell cultures in vitro.
Collapse
|