1
|
Fiber Synergy of Polyvinyl Alcohol and Steel Fibers on the Bond Behavior of a Hybrid Fiber-Reinforced Cementitious Composite. MATERIALS (BASEL, SWITZERLAND) 2024; 17:629. [PMID: 38591488 PMCID: PMC10856745 DOI: 10.3390/ma17030629] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Revised: 01/10/2024] [Accepted: 01/19/2024] [Indexed: 04/10/2024]
Abstract
Based on multi-scale characteristics inherent in the cracking process of cementitious composites, fibers with different geometric dimensions are simultaneously used to restrain the formation and development of cracks at different scales. Accordingly, hybrid fiber-reinforced cementitious composites (HyFRCCs) exhibit excellent bond behavior and deformation capacity in terms of tension and compression, accompanied by higher damage tolerance. Using these benefits of the mechanical properties of HyFRCCs, the structural performance of HyFRCC structures under complex loading conditions can be improved. To objectively evaluate the contributions of all fibers to the mechanical properties of HyFRCCs, steel macro-fibers, and polyvinyl alcohol (PVA) micro-fibers were used to design several reinforced cementitious composites. Four of the specimens were mono-fibrous cementitious composites, three specimens were cementitious composites reinforced with hybrid fibers, and one was a non-fibrous cementitious composite. The synergy effect of the steel and PVA fibers was analyzed using various fiber combinations. The results indicated a significant enhancement of the bonding properties of HyFRCCs through the incorporation of PVA and steel fibers. Specifically, the peak bond strength, peak slip displacement, and residual bond strength exhibited increments ranging from 31.0% to 41.7%, 60.6% to 118.4%, and 34.6% to 391.3%, respectively, in comparison to the reference test block. Notably, the combined presence of the PVA and steel fibers consistently demonstrated a positive confounding effect on the residual bond strength. However, negative confounding effects were observed in terms of the peak bond strength and peak slip displacement, particularly with 1.0% steel fiber content and 0.5% PVA fiber content.
Collapse
|
2
|
Simulation of Tetrahedral Profiled Carbon Rovings for Concrete Reinforcements. MATERIALS (BASEL, SWITZERLAND) 2023; 16:2767. [PMID: 37049062 PMCID: PMC10095989 DOI: 10.3390/ma16072767] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/04/2023] [Revised: 03/21/2023] [Accepted: 03/24/2023] [Indexed: 06/19/2023]
Abstract
Textile reinforcements are increasingly establishing their position in the construction industry due to their high tensile properties and corrosion resistance for concrete applications. In contrast to ribbed monolithic steel bars with a defined form-fit effect, the conventional carbon rovings' bond force is transmitted primarily by an adhesive bond (material fit) between the textile surface and the surrounding concrete matrix. As a result, relatively large bonding lengths are required to transmit bond forces, resulting in inefficient material utilization. Novel solutions such as tetrahedral profiled rovings promise significant improvements in the bonding behavior of textile reinforcements by creating an additional mechanical interlock with the concrete matrix while maintaining the high tensile properties of carbon fibers. Therefore, simulative investigations of tensile and bond behavior have been conducted to increase the transmittable bond force and bond stiffness of profiled rovings through a defined roving geometry. Geometric and material models were thus hereby developed, and tensile and pullout tests were simulated. The results of the simulations and characterizations could enable the optimization of the geometric parameters of tetrahedral profiled rovings to achieve better bond and tensile properties and provide basic principles for the simulative modeling of profiled textile reinforcements.
Collapse
|
3
|
Improved Tensile and Bond Properties through Novel Rod Constructions Based on the Braiding Technique for Non-Metallic Concrete Reinforcements. MATERIALS (BASEL, SWITZERLAND) 2023; 16:2459. [PMID: 36984338 PMCID: PMC10058978 DOI: 10.3390/ma16062459] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Revised: 03/14/2023] [Accepted: 03/15/2023] [Indexed: 06/18/2023]
Abstract
Textile reinforcements have established themselves as a convincing alternative to conventional steel reinforcements in the building industry. In contrast to ribbed steel bars that ensure a stable mechanical interlock with concrete (form fit), the bonding force of smooth carbon rovings has so far been transmitted primarily by an adhesive bonding with the concrete matrix (material fit). However, this material fit does not enable the efficient use of the mechanical load capacity of the textile reinforcement. Solutions involving surface-profiled rods promise significant improvements in the bonding behavior by creating an additional mechanical interlock with the concrete matrix. An initial analysis was carried out to determine the effect of a braided rod geometry on the bonding behavior. For this purpose, novel braided rods with defined surface profiling consisting of several carbon filament yarns were developed and characterized in their tensile and bond properties. Further fundamental examinations to determine the influence of the impregnation as well as the application of a pre-tension during its consolidation in order to minimize the rod elongation under load were carried out. The investigations showed a high potential of the impregnated surface-profiled braided rods for a highly efficient application in concrete reinforcements. Hereby, a complete impregnation of the rod with a stiff polymer improved the tensile and bonding properties significantly. Compared to unprofiled reinforcement structures, the specific bonding stress could be increased up to 500% due to the strong form-fit effect of the braided rods while maintaining the high tensile properties.
Collapse
|
4
|
Active SMA Fibers' Effect on the Pullout Behavior of a Steel Bar Embedded in Concrete. MATERIALS (BASEL, SWITZERLAND) 2023; 16:1947. [PMID: 36903062 PMCID: PMC10003967 DOI: 10.3390/ma16051947] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/05/2023] [Revised: 02/16/2023] [Accepted: 02/22/2023] [Indexed: 06/18/2023]
Abstract
This study investigated the bond behavior and radial crack between concrete and reinforcing bars using cold-drawn shape memory alloy (SMA) crimped fibers controlled by the temperature and volume fraction of the fibers. In this novel approach, the concrete specimens containing cold-drawn SMA crimped fibers with 1.0% and 1.5% volume fractions of cold-drawn SMA fibers were prepared. After that, the specimens were heated to 150 °C to generate recovery stress and activate prestressing within the concrete. The bond strength of specimens was estimated by pullout test using the universal testing machine (UTM). Furthermore, the cracking patterns were investigated using radial strain measured by a circumferential extensometer. The results showed that adding up to 1.5% of SMA fibers improved the bond strength by 47.9% and reduced radial strain by more than 54%. Thus, heating specimens containing SMA fibers showed improved bond behavior compared with non-heated specimens with the same volume fraction.
Collapse
|
5
|
Bond Behavior of Steel Rebar Embedded in Cementitious Composites Containing Polyvinyl Alcohol (PVA) Fibers and Carbon Nanotubes (CNTs). Polymers (Basel) 2023; 15:polym15040884. [PMID: 36850166 PMCID: PMC9960286 DOI: 10.3390/polym15040884] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2023] [Revised: 02/06/2023] [Accepted: 02/08/2023] [Indexed: 02/12/2023] Open
Abstract
In this study, pull-out tests were conducted to investigate the bond behavior of a rebar embedded in cementitious composites with polyvinyl alcohol (PVA) fibers and carbon nanotubes (CNTs). In the cementitious composites, the binder consisted of ordinary Portland cement, blast furnace slag, and fly ash, with a weight ratio of 39.5, 21.0 and 39.5%, respectively, while the nonbinder consisted of quartzite sand, lightweight aggregate, superplasticizer, and shrinkage-reducing admixture. The water/binder ratio and volume fractions of the PVA fibers were 32.9% and 2.07%, respectively. In the test program, the rebar diameter (D13, D16, and D19) and CNTs mix ratio (0.0, 0.1, 0.2, and 0.3 wt.%) were considered as the test variables. The test results showed that the bond strength of a rebar increased as the rebar diameter decreased or as the CNTs mix ratio increased. Based on the test results, a new, simple model has been proposed with consideration of the rebar diameter, as well as the CNTs mix ratio. Comparing the test results, it was investigated that the proposed model generally represented the bond behavior well, including the bond strength and the corresponding slip of a rebar embedded in PVA cementitious composites, with or without CNTs.
Collapse
|
6
|
Experimental Study on Bond Behavior of Glass Textile Mesh in Earth-Based Matrix. MATERIALS (BASEL, SWITZERLAND) 2023; 16:1161. [PMID: 36770164 PMCID: PMC9920028 DOI: 10.3390/ma16031161] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Revised: 01/21/2023] [Accepted: 01/23/2023] [Indexed: 06/18/2023]
Abstract
The bond behavior between the textile and the earth-based matrix determined the reinforcement effectiveness of the composite systems. This paper presented a pull-out experimental study on the glass textile mesh reinforced earth-based matrix. The bond behavior was studied using different development length, mesh spacing size and matrix thickness, with a total of 32 experimental specimens. The test results showed that the peak pull-out force had increased by 31.7% and 40.5% with 200 mm and 300 mm versus 100 mm development length, respectively. The 16 mm compared to 10 mm matrix thickness specimens had a high strength improvement (9.73%) because the elevated thickness had increased the matrix strength. However, the 20 mm versus 10 mm mesh spacing size specimens had achieved a slight reduction (5.72%) due to the reduction in the number of textiles along the weft direction. The failure mode shifted from pulling out, compound modes (both pulling out and textile rupture) to textile rupture mainly accompanied by elevated development length. In addition, we discussed the applicability of the trilinear bond-slip model on the earth-based matrix and proposed a method based on the fracture energy concept for estimating the effective development length, which could provide a reference for future research.
Collapse
|
7
|
Bond Modification of Carbon Rovings through Profiling. MATERIALS (BASEL, SWITZERLAND) 2022; 15:5581. [PMID: 36013718 PMCID: PMC9416130 DOI: 10.3390/ma15165581] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Revised: 08/10/2022] [Accepted: 08/11/2022] [Indexed: 06/15/2023]
Abstract
The load-bearing behavior and the performance of composites depends largely on the bond between the individual components. In reinforced concrete construction, the bond mechanisms are very well researched. In the case of carbon and textile reinforced concrete, however, there is still a need for research, especially since there is a greater number of influencing parameters. Depending on the type of fiber, yarn processing, impregnation, geometry, or concrete, the proportion of adhesive, frictional, and shear bond in the total bond resistance varies. In defined profiling of yarns, we see the possibility to increase the share of the shear bond (form fit) compared to yarns with a relatively smooth surface and, through this, to reliably control the bond resistance. In order to investigate the influence of profiling on the bond and tensile behavior, yarns with various profile characteristics as well as different impregnation and consolidation parameters are studied. A newly developed profiling technique is used for creating a defined tetrahedral profile. In the article, we present this approach and the first results from tensile and bond tests as well as micrographic analysis with profiled yarns. The study shows that bond properties of profiled yarns are superior to conventional yarns without profile, and a defined bond modification through variation of the profile geometry as well as the impregnation and consolidation parameters is possible.
Collapse
|
8
|
A Review on the Physical Parameters Affecting the Bond Behavior of FRP Bars Embedded in Concrete. Polymers (Basel) 2022; 14:1796. [PMID: 35566964 PMCID: PMC9104929 DOI: 10.3390/polym14091796] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Revised: 04/14/2022] [Accepted: 04/18/2022] [Indexed: 11/17/2022] Open
Abstract
The present study is a detailed literal survey on the bond behavior of FRP (Fiber Reinforced Polymer) reinforcing bars embedded in concrete. There is an urgent need for the accurate assessment of the parameters affecting the FRP-concrete bond and quantification of these effects. A significant majority of the previous studies could not derive precise and comprehensive conclusions on the effects of each of these parameters. The present study aimed at listing all of the physical parameters affecting the concrete-FRP bond, presenting the effects of each of these parameters based on the common opinions of the previous researchers and giving reasonable justifications on these effects. The studies on each of the parameters are presented in detailed tables. Among all listed parameters, the surface texture was established to have the most pronounced effect on the FRP-concrete bond strength. The bond strength values of the bars with coarse sand-coating exceeded the respective values of the fine sand-coated ones. However, increasing the concrete strength was found to result in a greater improvement in bond behavior of fine sand-coated bars due to the penetration of concrete particles into the fine sand-coating layer. The effects of fiber type, bar diameter and concrete compressive strength on the bar bond strength was shown to primarily originate from the relative slip of fibers inside the resin of the bar, also known as the shear lag effect.
Collapse
|
9
|
Analytical Model for Bond Behavior Prediction of CFRP-Concrete Joints with End Anchorage. Polymers (Basel) 2021; 13:polym13213684. [PMID: 34771240 PMCID: PMC8587106 DOI: 10.3390/polym13213684] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2021] [Revised: 09/23/2021] [Accepted: 10/21/2021] [Indexed: 11/17/2022] Open
Abstract
Use of the end anchorages can significantly control the debonding of CFRP-to-concrete bond interface, and improve the bearing capacity of CFRP strengthened concrete member. An analytical model was presented in this paper to predict the bond behavior and debonding process of CFRP-concrete bonded joint with end anchorage. The calculation formulas of bond failure load and effective bond length for anchored CFRP-concrete joint are derived from the proposed analytical model. According to these models and formulas, the influence of different bond lengths on the mechanical behaviors during the debonding process was analyzed. Results show the load-slip curves of end anchored CFRP-concrete joints could be divided into three branches: elastic stage, stable stage, and enhancement stage. As the bond length increases, the plateau length in stable stage increases. Besides, the bond failure load decreased firstly to a lower limit and then increased with the increase of bond length. The effective bond length of CFRP-concrete joint with end anchorage was longer than that of the external bonded joint, and the value of effective bond length for end anchored joint shall be at least 7.2/AB, where the parameters A and B were related to the interfacial properties of bonded joint. Furthermore, a single shear test was carried out on the end anchored CFRP-concrete bonded joint with different bond lengths, to verify the consistency of the proposed model and formulas. The analytical result of load-slip response at the load end, as well as the strain distribution of CFRP material and the bond failure load, was compared with the experimental result. The comparisons showed that the analytical results had a good agreement with the experimental results.
Collapse
|
10
|
Accelerated Aging Behavior in Alkaline Environments of GFRP Reinforcing Bars and Their Bond with Concrete. MATERIALS 2021; 14:ma14195700. [PMID: 34640100 PMCID: PMC8510303 DOI: 10.3390/ma14195700] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Revised: 09/20/2021] [Accepted: 09/24/2021] [Indexed: 11/24/2022]
Abstract
This study investigates the durability of glass fiber-reinforced polymer (GFRP) reinforcing bars (rebars) and their bond in concrete. Accelerated aging tests were first conducted on bare rebars that were either subjected to direct immersion in an alkaline solution or previously embedded in concrete before immersion in the solution (indirect immersion). Accelerated aging was conducted at different temperatures of the solution (20 °C, 40 °C and 60 °C) and for various periods up to 240 days. Residual tensile properties were determined for rebars subjected to direct immersion and served as input data of a predictive Arrhenius model. A large decrease in the residual tensile strength assigned to the alkali-attack of glass fibers was extrapolated in the long term, suggesting that direct immersion is very severe compared to actual service conditions. Short-beam tests were also performed on rebars conditioned under direct/indirect immersion conditions, but did not reveal any significant evolution of the interlaminar shear strength (ILSS). In a second part, bond tests were performed on pull-out specimens after immersion in the alkaline solution at different temperatures, in order to assess possible changes in the concrete/GFRP bond properties over aging. Results showed antagonistic effects, with an initial increase in bond strength assigned to a confinement effect of the rebar resulting from changes in the concrete properties over aging, followed by a decreasing trend possibly resulting from interfacial degradation. Complementary characterizations by scanning electron microscopy (SEM), differential scanning calorimetry (DSC) and Fourier transform infrared (FTIR) spectroscopy were also carried out to evaluate the effects of aging on the physical/microstructural properties of GFRPs.
Collapse
|
11
|
Bond Behavior of Reinforced Concrete Considering Freeze-Thaw Cycles and Corrosion of Stirrups. MATERIALS 2021; 14:ma14164732. [PMID: 34443253 PMCID: PMC8402155 DOI: 10.3390/ma14164732] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/17/2021] [Revised: 08/02/2021] [Accepted: 08/20/2021] [Indexed: 11/16/2022]
Abstract
In relatively cold environments, the combination of freeze-thaw and steel bar corrosion is a key factor affecting the durability of concrete. The adjustment of the stirrup ratio would change the mechanical performance of surrounding concrete, while the circumferential compressive stress can further improve the bonding performance. Hence, based on eccentrically tensioned specimens, the influence of corrosion of stirrups and freeze-thaw of concrete on bond properties is discussed in this paper. The monotonic pull-out test of reinforced concrete specimens is carried out to study the variation rules of bond strength and slip between steel bar and concrete under the coupling action of corrosion rate, freeze-thaw times and stirrup spacing. Based on the experimental data, the empirical formula for the ultimate bond strength is obtained, and a bond-slip constitutive model is established considering the stirrup spacing, stirrup corrosion rate and freeze-thaw times. Then, a refined finite element pull-out specimen model is established by ABAQUS simulation, and the numerical simulation results are compared with the real test ones, so as to make up for the deficiencies in the test and lay the foundation for further finite element analysis.
Collapse
|
12
|
Basic Mechanical Properties of Duplex Stainless Steel Bars and Experimental Study of Bonding between Duplex Stainless Steel Bars and Concrete. MATERIALS 2021; 14:ma14112995. [PMID: 34205945 PMCID: PMC8198329 DOI: 10.3390/ma14112995] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/10/2021] [Revised: 05/26/2021] [Accepted: 05/29/2021] [Indexed: 11/17/2022]
Abstract
In recent years, as a result of the large-scale use of stainless steel bars in production and life, people's demand for stainless steel bars has increased. However, existing research information on stainless steel bars is scant, especially the lack of research on the mechanical properties of duplex stainless steel bars and the bonding properties of duplex stainless steel bars to concrete. Therefore, this paper selects 177 duplex stainless steel bars with different diameters for room temperature tensile test, and then uses mathematical methods to provide suggestions for the values of their mechanical properties. The test results show that the duplex stainless steel bar has a relatively high tensile strength of 739 MPa, no significant yield phase, and a relatively low modulus of elasticity of 1.43 × 105 MPa. In addition, 33 specimens were designed to study the bonding properties of duplex stainless steel bars to concrete. In this paper, the effects of concrete strength, duplex stainless steel reinforcement diameter, the ratio of concrete cover to reinforcing steel diameter, and relative anchorage length on the bond stress were investigated, and a regression model was established based on the experimental results. The results show that, with the concrete strength concrete strength from C25 to C40, the compressive strength of concrete increased by 56.1%, the bond stress increased by 27%; the relative anchorage length has been increased from 3 to 6, the relative anchorage length has doubled, and the bond stress has increased by 13%; and, the ratio of concrete cover to reinforcing steel diameter increased to a certain range on the bond stress has no significant effect and duplex stainless steel reinforcement diameter has little effect on the bond stress. The ratio of concrete cover to reinforcing steel diameter from 3.3 to 4.5 and the bond stress increased by 24.7%. A ratio of concrete cover to reinforcing steel diameter greater than 4.5 has no significant effect on the bond stress, with the average bond stress value of 20.1 MPa. The duplex stainless steel bar diameter has little effect on the bond stress for the diameters of 12 mm, 16 mm, 25 mm duplex stainless steel bar, and their average bond stress is 19.9 MPa.
Collapse
|
13
|
Experimental Characterization of the FRCM-Concrete Interface Bond Behavior Assisted by Digital Image Correlation. SENSORS 2021; 21:s21041154. [PMID: 33562171 PMCID: PMC7914966 DOI: 10.3390/s21041154] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Revised: 02/02/2021] [Accepted: 02/04/2021] [Indexed: 11/16/2022]
Abstract
Digital Image Correlation (DIC) provides measurements without disturbing the specimen, which is a major advantage over contact methods. Additionally, DIC techniques provide full-field maps of response quantities like strains and displacements, unlike traditional methods that are limited to a local investigation. In this work, an experimental application of DIC is presented to investigate a problem of relevant interest in the civil engineering field, namely the interface behavior between externally bonded fabric reinforced cementitious mortar (FRCM) sheets and concrete substrate. This represents a widespread strengthening technique of existing reinforced concrete structures, but its effectiveness is strongly related to the bond behavior between composite fabric and underlying concrete. To investigate this phenomenon, a set of notched concrete beams are realized, reinforced with FRCM sheets on the bottom face, subsequently cured in different environmental conditions (humidity and temperature) and finally tested up to failure under three-point bending. Mechanical tests are carried out vis-à-vis DIC measurements using two distinct cameras simultaneously, one focused on the concrete front face and another focused on the FRCM-concrete interface. This experimental setup makes it possible to interpret the mechanical behavior and failure mode of the specimens not only from a traditional macroscopic viewpoint but also under a local perspective concerning the evolution of the strain distribution at the FRCM-concrete interface obtained by DIC in the pre- and postcracking phase.
Collapse
|
14
|
Finite Element Modeling of Bond Behavior of FRP and Steel Plates. MATERIALS 2021; 14:ma14040757. [PMID: 33562779 PMCID: PMC7915636 DOI: 10.3390/ma14040757] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/28/2020] [Revised: 01/25/2021] [Accepted: 02/01/2021] [Indexed: 11/29/2022]
Abstract
Strengthening systems for existing reinforced concrete (RC) structures are increasingly needed due to several problems such as degradation of materials over the time, underdesign, serviceability or seismic upgrading, or new code requirements. In the last decades, strengthening by fibers composite materials applied with various techniques (FRP, FRCM, NSM) were largely investigated and theoretical formulations have been introduced in national and international design guidelines. Although they are an excellent strengthening solution, steel plates may represent still a valid traditional alternative, due to low costs, ductile stress-strain behavior, simple and fast mounting with possibility of reusing the material. Guidelines for a correct design are still lack and, therefore, detailed models and design formulas are needed. In this paper, the bond behavior at the plate-concrete interface, which plays a key role for the effectiveness of the strengthening system, is analyzed by means of 3D finite element models calibrated on experimental results available in literature. Parametric analyses were carried out by changing some meaningful parameters.
Collapse
|
15
|
Characterization and Simulation of the Bond Response of NSM FRP Reinforcement in Concrete. MATERIALS 2020; 13:ma13071770. [PMID: 32283862 PMCID: PMC7179015 DOI: 10.3390/ma13071770] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/06/2020] [Revised: 03/29/2020] [Accepted: 04/07/2020] [Indexed: 11/17/2022]
Abstract
The near-surface mounted (NSM) technique with fiber reinforced polymer (FRP) reinforcement as strengthening system for concrete structures has been broadly studied during the last years. The efficiency of the NSM FRP-to-concrete joint highly depends on the bond between both materials, which is characterized by a local bond–slip law. This paper studies the effect of the shape of the local bond–slip law and its parameters on the global response of the NSM FRP joint in terms of load capacity, effective bond length, slip, shear stress, and strain distribution along the bonded length, which are essential parameters on the strengthening design. A numerical procedure based on the finite difference method to solve the governing equations of the FRP-to-concrete joint is developed. Pull-out single shear specimens are tested in order to experimentally validate the numerical results. Finally, a parametric study is performed. The effect of the bond–shear strength slip at the bond strength, maximum slip, and friction branch on the parameters previously described is presented and discussed.
Collapse
|
16
|
Bond-Slip Behavior between Stainless Steel Rebars and Concrete. MATERIALS 2020; 13:ma13040979. [PMID: 32098233 PMCID: PMC7078846 DOI: 10.3390/ma13040979] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/04/2020] [Revised: 02/19/2020] [Accepted: 02/20/2020] [Indexed: 11/16/2022]
Abstract
Maintenance of reinforced concrete structures is a prevailing topic, especially with regard to lifeline structures and bridges, many of which are now designed with a service life beyond 100 years. Reinforcement made of ordinary (carbon) steel may corrode in aggressive environments. Stainless steel, being much more resistant to corrosion, is a valid solution to facilitate the protection of the works, increasing the service life and reducing the need for repair and maintenance. Despite the potential for stainless steel to reduce maintenance costs, studies investigating the influence of stainless steel on the behavior of reinforced concrete structures are limited. This study investigated the bond behavior of stainless steel rebars by means of experimental tests on reinforced concrete specimens with different concrete cover thicknesses, concrete strengths, and bar diameters. In each case, identical specimens with carbon steel reinforcement were tested for comparison. The failure modes of the specimens were examined, and a bond stress–slip relationship for stainless steel bars was established. This research shows that the bond behavior of stainless steel rebars is comparable to that of carbon steel bars.
Collapse
|
17
|
Research on the Bond Behavior of Preplaced Aggregate Concrete-Filled Steel Tube Columns. MATERIALS 2020; 13:ma13020300. [PMID: 31936537 PMCID: PMC7013690 DOI: 10.3390/ma13020300] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/21/2019] [Revised: 12/27/2019] [Accepted: 01/07/2020] [Indexed: 11/16/2022]
Abstract
In order to investigate the bond behavior of preplaced aggregate concrete-filled steel tube (CFT-PAC) columns and the difference of bond behavior between CFT-PAC columns and normal concrete-filled steel tube (CFT-NC) columns, a total of 11 columns were prepared and the push-out tests were conducted. The experimental parameters included the type of concrete (preplaced aggregate concrete and normal concrete), concrete strength (C40, C50 and C60), cross-section dimension (D = 219 mm, 299 mm and 351 mm) and the thickness of steel tube (t = 6 mm and 8 mm). The results indicated that the CTF-PAC columns had a similar load-slip curves with CFT-NC columns. The bond stresses of the CFT-PAC columns were higher than that of the PAC-NC columns at the same concrete strength. Increasing compressive strength of PAC increased the critical bond strength and bond strength of CFT-PAC columns. With an increase of the L/D ratio, both of the slip corresponding to peak load and bond strength of CFT-PAC columns exhibited an increasing trend. A rise in the D/t ratio led to a decrease in the bond stress of CFT-PAC columns and an increase in slip corresponding to the peak load of CFT-PAC columns. The proposed bond stress–slip relationship model considerably matched the bond stress–slip relationship of CFT-PAC columns.
Collapse
|
18
|
Effects of Defects on Bond Behavior of Fiber Reinforced Cementitious Matrix Materials. MATERIALS 2020; 13:ma13010164. [PMID: 31906312 PMCID: PMC6981375 DOI: 10.3390/ma13010164] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/11/2019] [Revised: 12/24/2019] [Accepted: 12/27/2019] [Indexed: 11/16/2022]
Abstract
High-strength fibers embedded in inorganic matrix i.e., Fiber Reinforced Cementitious Mortar materials (FRCM) are commonly used as strengthening technique for existing masonry structures, due to the low sensitivity to debonding phenomena between substrate and matrix. Nevertheless, the use of lime or cement-based matrix instead of epoxy adhesive implies that attention has to be paid to the bond behavior between the fibers and the matrix, since sliding phenomena and cohesive failures in the mortar matrix can occur. The paper aims to investigate the effect of the mechanical properties of fiber and matrix on the FRCM efficiency, and potential geometrical defects, typical of real applications. The aim is to analyze the mechanical behavior of the FRCM system by simulating hypothetical bond tests, as they are usually performed in laboratories. The bond test has a significant role, as it is used for the qualification of the material, providing sometimes very scattered results. Hence, it is particularly important and greatly discussed in the scientific community and among manufactures and practitioners. The purpose is to understand where this variability could derive from and possibly how to contain it, to improve the characterization of FRCM systems. A mechanical model has been proposed to simulate the usual bond test to focus and stress the way in which each fiber slips out of the matrix as the load increases; and this has been recognized as the main reason for scattered results in bond tests. The model was then applied to the typical cases of PBO-FRCM and Glass-FRCM, hence considering different ratios for the fiber and matrix properties.
Collapse
|
19
|
Influence of Surface Preparation Method on the Bond Behavior of Externally Bonded CFRP Reinforcements in Concrete. MATERIALS (BASEL, SWITZERLAND) 2019; 12:E414. [PMID: 30700012 PMCID: PMC6384808 DOI: 10.3390/ma12030414] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/18/2018] [Revised: 12/30/2018] [Accepted: 01/28/2019] [Indexed: 11/16/2022]
Abstract
In last decades significant investigation has been carried out in order to predict the bond strength of externally bonded reinforcement (EBR) systems with carbon fiber reinforced polymer (CFRP) materials in concrete and, as consequence of that, many analytical expressions can be found in the literature, including in standards. However, these expressions do not account for the influence of several parameters on bond behavior such as the type of surface preparation which is a mandatory and critical task in the strengthening application. The present work gives contributions to reduce this lack of knowledge. For this purpose, an experimental program composed of single-lap shear tests was carried out, the main parameters studied being: (i) the type of concrete surface preparation (i.e., grinding and sandblasting) and (ii) the bond length. Prior to the application of the EBR CFRP system, the roughness level provided by the different methods of surface preparation was characterized by a laser sensor. Test results revealed that sandblasting concrete surface preparation yielded higher values, in terms of maximum shear force and fracture energy. Finally, existing expressions in standards were upgraded in order to account for the concrete surface roughness level in the estimation of the bond strength.
Collapse
|
20
|
Behaviour of Prestressed CFRP Anchorages during and after Freeze-Thaw Cycle Exposure. Polymers (Basel) 2018; 10:polym10060565. [PMID: 30966599 PMCID: PMC6404005 DOI: 10.3390/polym10060565] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2018] [Revised: 05/09/2018] [Accepted: 05/17/2018] [Indexed: 11/16/2022] Open
Abstract
The long-term performance of externally-bonded reinforcements (EBR) on reinforced concrete (RC) structures highly depends on the behavior of constituent materials and their interfaces to various environmental loads, such as temperature and humidity exposure. Although significant efforts have been devoted to understanding the effect of such conditions on the anchorage resistance of unstressed EBR, with or without sustained loading, the effect of a released prestressing has not been thoroughly investigated. For this purpose, a series of experiments has been carried out herein, with concrete blocks strengthened with carbon fiber-reinforced polymer (CFRP) strips, both unstressed, as well as prestressed using the gradient anchorage. The gradient anchorage is a non-mechanical technique to anchor prestressed CFRP by exploiting the accelerated curing property of epoxy under higher temperatures and segment-wise prestress-force releasing. Subsequently, strengthened blocks are transferred into a chamber for exposure in dry freeze-thaw cycles (FTC). Following FTC exposure, the blocks are tested in a conventional lap-shear test setup to determine their residual anchorage resistance and then compared with reference specimens. Blocks were monitored during FTC by conventional and Fabry–Pérot-based fiber optic strain (FOS) sensors and a 3D-digital image correlation (3D-DIC) system during gradient application and lap-shear testing. Results indicate a reduction of residual anchorage resistance, stiffness and deformation capacity of the system after FTC and a change in the failure mode from concrete substrate to epoxy-concrete interface failure. It was further observed that all of these properties experienced a more significant reduction for prestressed specimens. These findings are presented with a complementary finite element model to shed more light onto the durability of such systems.
Collapse
|