1
|
Abbreviated Urine Collection Compared With 24-Hour Urine Collection for Measuring Creatinine Clearance in Adult Critically Ill Patients: A Systematic Review. Ann Pharmacother 2024:10600280241241820. [PMID: 38619016 DOI: 10.1177/10600280241241820] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/16/2024] Open
Abstract
OBJECTIVE To evaluate the accuracy of abbreviated urine collection (≤12 hours) compared with 24-hour urine collection for measuring creatinine clearance (CrCl) in critically ill adult patients. DATA SOURCES We searched PubMed, Embase, Web of Science, Google Scholar, and ProQuest Dissertations and Thesis Global; screened reference lists of included studies; and contacted the authors when needed. English studies only were considered with no restriction on dates. STUDY SELECTION AND DATA EXTRACTION After duplicate removal, 2 reviewers screened titles/abstracts, reviewed full-text articles, and extracted data independently. Studies that compared abbreviated versus 24-hour urine collection for measuring CrCl were included. We assessed the risk of bias using the QUADAS-2 tool. We extracted correlation coefficients, mean prediction errors (ME)-as a measure of bias, and root mean squared prediction errors (RMSE)-as a measure of precision. DATA SYNTHESIS Five studies were included, comprising 528 adult critically ill adults from surgical, medical, and trauma intensive care units (ICUs). Three studies had high risk of bias, and 2 had low risk. The studies evaluated different durations of urine collection, including 30-minute, 2-hour, 4-hour, 6-hour, and 12-hour. Mean 24-hour CrCl ranged from 57 mL/min/1.73 m2 to 103 mL/min. Abbreviated urine collection led to CrCl that correlated well with the 24-hour measured CrCl (correlation coefficient ranged from 0.8 to 0.95). Mean prediction error ranged from 5 mL/min/1.73 m2 to 16 mL/min (from 8% to 25% of the 24-hour CrCl). Root mean squared prediction error calculated from 1 study was 30.5 mL/min/1.73 m2. RELEVANCE TO PATIENT CARE AND CLINICAL PRACTICE Abbreviated urine collection is used to measure CrCl for renal drug dosing in critically ill patients, but its accuracy is not well-established. CONCLUSIONS Abbreviated urine collection may overestimate CrCl compared with 24-hour urine collection. Larger, well-conducted studies are needed to evaluate the accuracy of CrCl measured using different durations of urine collection in critically ill patients.
Collapse
|
2
|
UAS™-A Urine Preservative for Oncology Applications. Cancers (Basel) 2023; 15:3119. [PMID: 37370729 DOI: 10.3390/cancers15123119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Revised: 05/26/2023] [Accepted: 06/07/2023] [Indexed: 06/29/2023] Open
Abstract
Liquid biopsy is a revolutionary tool that is gaining momentum in the field of cancer research. As a body fluid, urine can be used in non-invasive diagnostics for various types of cancer. We investigated the performance of UAS™ as a preservative for urinary analytes. Firstly, the need for urine preservation was investigated using urine samples from healthy volunteers. Secondly, the performance of UAS™ was assessed for cell-free DNA (cfDNA) and host cell integrity during storage at room temperature (RT) and after freeze-thaw cycling. Finally, UAS™ was used in a clinical setting on samples from breast and prostate cancer patients. In the absence of a preservative, urinary cfDNA was degraded, and bacterial overgrowth occurred at RT. In urine samples stored in UAS™, no microbial growth was seen, and cfDNA and cellular integrity were maintained for up to 14 days at RT. After freeze-thaw cycling, the preservation of host cell integrity and cfDNA showed significant improvements when using UAS™ compared to unpreserved urine samples. Additionally, UAS™ was found to be compatible with several commercially available isolation methods.
Collapse
|
3
|
Optimising urinary catecholamine metabolite diagnostics for neuroblastoma. Pediatr Blood Cancer 2023; 70:e30289. [PMID: 37010353 DOI: 10.1002/pbc.30289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Revised: 02/02/2023] [Accepted: 02/20/2023] [Indexed: 04/04/2023]
Abstract
INTRODUCTION The analysis of urinary catecholamine metabolites is a cornerstone of neuroblastoma diagnostics. Currently, there is no consensus regarding the sampling method, and variable combinations of catecholamine metabolites are being used. We investigated if spot urine samples can be reliably used for analysis of a panel of catecholamine metabolites for the diagnosis of neuroblastoma. METHODS Twenty-four-hour urine or spot urine samples were collected from patients with and without neuroblastoma at diagnosis. Homovanillic acid (HVA), vanillylmandelic acid (VMA), dopamine, 3-methoxytyramine, norepinephrine, normetanephrine, epinephrine and metanephrine were measured by high-performance liquid chromatography coupled with fluorescence detection (HPLC-FD) and/or ultra-performance liquid chromatography coupled with electrospray tandem mass spectrometry (UPLC-MS/MS). RESULTS Catecholamine metabolite levels were measured in urine samples of 400 neuroblastoma patients (24-hour urine, n = 234; spot urine, n = 166) and 571 controls (all spot urine). Excretion levels of catecholamine metabolites and the diagnostic sensitivity for each metabolite were similar in 24-hour urine and spot urine samples (p > .08 and >.27 for all metabolites). The area under the receiver-operating-characteristic curve (AUC) of the panel containing all eight catecholamine metabolites was significantly higher compared to that of only HVA and VMA (AUC = 0.952 vs. 0.920, p = .02). No differences were observed in metabolite levels between the two analysis methods. CONCLUSION Catecholamine metabolites in spot urine and 24-hour urine resulted in similar diagnostic sensitivities. The Catecholamine Working Group recommends the implementation of spot urine as standard of care. The panel of eight catecholamine metabolites has superior diagnostic accuracy over VMA and HVA.
Collapse
|
4
|
Urine collection techniques in non-toilet trained children: Switzerland's paediatric office practices in 2022. Acta Paediatr 2023. [PMID: 36932711 DOI: 10.1111/apa.16758] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/15/2023] [Revised: 03/14/2023] [Accepted: 03/15/2023] [Indexed: 03/19/2023]
|
5
|
Urine collection methods in precontinent children treated at the paediatric emergency department. Acta Paediatr 2023; 112:550-556. [PMID: 36463432 DOI: 10.1111/apa.16614] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/07/2022] [Revised: 11/29/2022] [Accepted: 12/01/2022] [Indexed: 12/05/2022]
Abstract
AIM To describe the urine collection methods used in precontinent children presenting at the Paediatric Emergency Department (PED) and compare results and contamination rates. METHODS Retrospective observational cohort study that included 1678 urine cultures collected in infants <24 months of age between January 2016 and December 2019. Urine cultures were compared based on collection technique, sex and patient age. RESULTS In total, 60.4% of samples were collected by clean-catch urine collection (CCUC), 26.4% by urethral catheterisation (UC) and 13.2% by urine bag (UB). Contamination rates were 2.9% (95% CI 1.3, 4.4) for UC, 11.3% (95% CI 9.3, 13.2) for CCUC and 23.4% (95% CI 17.8, 29.0) for UB. Significant differences in contamination rates were found between UC and CCUC in the 6-12-month age group (1.9% [95% CI 0.0-4.0] versus 12.0% [95% CI 7.2-16.8] [p < 0.0009]), and between UC and UB for all ages. CONCLUSIONS CCUC is the most common method for urine culture collection in infants <24 months of age at the PED in our centre. UC has the lowest contamination rates, but significant differences were only observed between CCUC and UC in the 6-12-month age group. CCUC is a non-invasive alternative for urine collection in infants.
Collapse
|
6
|
Technical note: A procedure to place urinary catheters in 1-week and 6-week-old preweaned Holstein heifer calves for the in vivo evaluation of intestinal permeability. J Anim Sci 2022; 100:6605033. [PMID: 35679611 DOI: 10.1093/jas/skac213] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Accepted: 06/07/2022] [Indexed: 11/13/2022] Open
Abstract
Oral administration of indigestible markers and subsequent urine collection is a useful method to determine in vivo gastrointestinal tract (GIT) permeability in cattle for research purposes. However, urine sampling techniques often rely on total waste collection, which reduces the ability to perform more frequent sampling and obtain accurate volumes and sterile samples. An alternative is urethral catheterization, though the feasibility of this technique has not been thoroughly tested in preweaned Holstein heifer calves. The study objective was to develop a urethral catheter placement procedure in preweaned Holstein heifer calves for continuous and accurate urine collection to evaluate GIT permeability using an indigestible marker. Fifteen Holstein heifer calves had catheters placed at approximately 1 week (8.0 ± 1.5 d) and 6 weeks (40.0 ± 1.5 d) of age. During the procedure, calves were individually housed and restrained. The vulva was sterilized and then a sterile, lubricated speculum was inserted into the vagina. A sterile 0.09 cm diameter guidewire was guided into a lubricated, sterile 10 French Foley catheter. The catheter was inserted at approximately 5 through 7 cm into the urethral opening, guided into the bladder, and the catheter balloon was filled with 10 mL of water. The guidewire was removed, and urine flow confirmed correct placement before a 4 L urinary drainage bag was attached to the catheter. After catheterization (24 h), 1 L of chromium (Cr)-ethylenediaminetetraacetic acid was orally dosed to the calves. Calf health observations were made six times over a 48-h period and any occurrence of vaginal discharge, tissue discharge in catheter, bleeding, inflammation, or abnormal urine was considered a localized reaction. Proportion of localized reactions for each age group was determined using Microsoft Excel, and total Cr output was analyzed using PROC GLIMMIX. Localized reactions occurred for 20.0% of the 1-week-old calves and 13.3% of the 6-week-old calves. In the first 4 h, urine was collected every 15 min and there were no overall Cr output differences (P = 0.38; 10.28 ± 3.21 mg Cr) when comparing 1- and 6-week-old calves. However, 1-week-old calves tended (P = 0.08) to have greater overall Cr output at 480 min (19.2%) and 1,440 min (41.9%) when compared to 6-week-old calves. In summary, urinary catheterization is a viable urinary collection method for the determination of in vivo GIT permeability in preweaned Holstein heifer calves.
Collapse
|
7
|
Use of Cotton Balls in Diapers for Collection of Urine Samples Impacts the Analysis of Routine Chemistry Tests: An Evaluation of Cotton Balls, Diapers, and Chemistry Analyzers. J Pediatr 2022; 245:179-183.e8. [PMID: 35248569 DOI: 10.1016/j.jpeds.2022.02.051] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Revised: 02/23/2022] [Accepted: 02/24/2022] [Indexed: 11/25/2022]
Abstract
OBJECTIVE To evaluate the suitability of urine samples collected with cotton balls placed into diapers for routine laboratory chemistry analyses. STUDY DESIGN Twenty pools of residual unpreserved urine samples were separated into control and treated aliquots. The treated samples were absorbed into 2 different brands of cotton balls, wrapped in 3 different brands of diapers, and incubated at 37°C for 1 hour. The urine-soaked cotton balls were placed into a syringe and expressed via plunger depression. Urine sodium, potassium, creatinine, urea, calcium, magnesium, inorganic phosphorus, albumin, and total protein were measured on all samples on 5 automated clinical chemistry platforms: Ortho Vitros 4600, Siemens Dimension Vista 500, Beckman Coulter AU5822, Roche Cobas 6000, and Abbott Architect c8000 at 5 separate hospital laboratories. Criteria used to exclude the presence of significant effects of urine from presoaked cotton balls in a diaper on the measurement of chemistry laboratory tests were R2 >0.95, slope of 0.9-1.1, and mean bias within ±10%. RESULTS Albumin and total protein measurements demonstrated significant negative bias in urine from both brands of presoaked cotton balls with all brands of diapers on all 5 chemistry platforms compared with the control urine. We did not observe a significant effect of presoaking urine in cotton balls in a diaper on the measurement of sodium, inorganic phosphorus, and urea. The remaining tests demonstrated significant effects when measured in urine from presoaked cotton balls and/or diapers that were specific to the chemistry analyzer platform or diaper. CONCLUSIONS Diaper and cotton ball-based urine collection significantly impacts the measurement of several common chemistry assays.
Collapse
|
8
|
Investigating Risk Factors for Urine Culture Contamination in Outpatient Clinics: A New Avenue for Diagnostic Stewardship. ANTIMICROBIAL STEWARDSHIP & HEALTHCARE EPIDEMIOLOGY : ASHE 2022; 2. [PMID: 35445218 PMCID: PMC9016366 DOI: 10.1017/ash.2021.260] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Mixed flora in urine cultures usually occur due to preanalytic contamination. In our outpatient urology clinic, we detected a high prevalence of mixed flora (46.2%), which was associated with female sex and older age. Patient education did not influence the rate of mixed flora. Future efforts should target high-risk patients.
Collapse
|
9
|
Estimating urine volume from the urine creatinine concentration. Nephrol Dial Transplant 2021; 38:811-818. [PMID: 34850163 DOI: 10.1093/ndt/gfab337] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2021] [Indexed: 11/12/2022] Open
Abstract
Spot determinations of the urine creatinine concentration are widely used as a substitute for 24-hour urine collections. Expressed as the amount excreted per gram of creatinine, urine concentrations in a single-voided sample are often used to estimate 24-hour excretion rates of protein, sodium, potassium, calcium, magnesium, urea, and uric acid. These estimates are predicated on the assumption that daily creatinine excretion equals 1 gm (and that a urine creatinine concentration of 100 mg/dl reflects a 1 Liter 24-hour urine volume). Such estimates are invalid if the serum creatinine concentration is rising or falling. In addition, because creatinine excretion is determined by muscle mass, the assumption that 24-hour urine creatinine excretion equals 1 gm yields a misleading estimate at the extremes of age and body size. In this review we evaluate seven equations for the accuracy of their estimates of urine volume based on urine creatinine concentrations in actual and idealized patients. None of the equations work well in patients who are morbidly obese or in patients with markedly decreased muscle mass. In other patients, estimates based on a reformulation of the Cockroft-Gault equation are reasonably accurate. A recent study based on this relationship found a high strength of correlation between estimated and measured urine output with chronic kidney disease (CKD) studied in the African American Study of Kidney Disease (AASK) trial and for the patients studied in the CKD Optimal Management with Binders and NictomidE (COMBINE) trial. However, the equation systematically underestimated urine output in the AASK trial. Hence, an intercept was added to account for the bias in estimated output. A more rigorous equation, derived from an ambulatory Swiss population, that includes body mass index and models the non-linear accelerated decline in creatinine excretion with age, could potentially be more accurate in overweight and elderly patients. In addition to extremes of body weight and muscle mass, decreased dietary intake or reduced hepatic synthesis of creatine, a precursor of creatinine, or ingestion of creatine supplements will also result in inaccurate estimates. These limitations must be appreciated to rationally use predictive equations to estimate urine volume. If the baseline urine creatinine concentration is determined in a sample of known volume, subsequent urine creatinine concentrations will reveal actual urine output as well as the change in urine output. Given the constraints of the various estimating equations, a single baseline timed collection may be more useful strategy for monitoring urine volume than entering anthropomorphic data into a calculator.
Collapse
|
10
|
Patient-Centered Telehealth Solution for Observed Urine Collections in Substance Use Disorder Care Delivery During COVID-19 and Beyond. J Patient Exp 2021; 8:23743735211033128. [PMID: 34377769 PMCID: PMC8330461 DOI: 10.1177/23743735211033128] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Patients with substance use disorder (SUD) rely upon urine drug testing to support treatment adherence and to mitigate relapse. Before the onset of coronavirus 2019 (COVID-19), the logistical challenges of randomized observed collections for urine drug testing for the patient were significant. During COVID-19, these barriers were often insurmountable. Since SUD patients represent a population at a higher risk for complications from COVID-19, an alternative strategy to support COVID-19 testing was urgently needed. We designed and deployed a telehealth-based solution in which patients could use mobile devices to connect with trained collection professionals to perform observed urine collections, often referred to a UA (urinalysis). The solution was designed with patient-centered best practices for telehealth, stigma prevention, trauma-informed, empathy and compassion, and to remove barriers to access to care. This approach demonstrated high patient satisfaction scores thereby proving that it is possible to provide urine collection services in the patient's home via a telehealth technology, while still upholding SUD testing integrity best practices. This study lays the path for a more patient-centered way to support this population.
Collapse
|
11
|
Microalbuminuria After Kidney Transplantation Predicts Cardiovascular Morbidity. Front Med (Lausanne) 2021; 8:635847. [PMID: 33912576 PMCID: PMC8071984 DOI: 10.3389/fmed.2021.635847] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Accepted: 03/08/2021] [Indexed: 11/17/2022] Open
Abstract
Background: Microalbuminuria is a well-characterized marker of kidney malfunction, both in diabetic and non-diabetic populations, and is used as a prognostic marker for cardiovascular morbidity and mortality. A few studies implied that it has the same value in kidney transplanted patients, but the information relies on spot or dipstick urine protein evaluations, rather than the gold standard of timed urine collection. Methods: We revisited a cohort of 286 kidney transplanted patients, several years after completing a meticulously timed urine collection and assessed the prevalence of major cardiovascular adverse events (MACE) in relation to albuminuria. Results: During a median follow up of 8.3 years (IQR 6.4–9.1) 144 outcome events occurred in 101 patients. By Kaplan-Meier analysis microalbuminuria was associated with increased rate of CV outcome or death (p = 0.03), and this was still significant after stratification according to propensity score quartiles (p = 0.048). Time dependent Cox proportional hazard analysis showed independent association between microalbuminuria and CV outcomes 2 years following microalbuminuria detection (HR 1.83, 95% CI 1.07–2.96). Conclusions: Two years after documenting microalbuminuria in kidney transplanted patients, their CVD risk was increased. There is need for primary prevention strategies in this population and future studies should address the topic.
Collapse
|
12
|
Abstract
Urinalysis could be helpful to investigate the health status of giraffes held in captivity using noninvasive methods to avoid animal handling or anesthesia. We collected 52 voided urine samples from 20 giraffes of different ages, sexes, and subspecies from the ground. To evaluate potential interference by soil contaminants, a pilot study was performed using 20 urine samples obtained from 10 cows. All bovine and 29 giraffe samples were subjected to routine urinalysis including urine specific gravity (USG). All samples were analyzed for urine total protein (uTP), urine creatinine (uCrea) concentration, and urine protein-to-urine creatinine ratio (UPC). Urinary proteins were separated by SDS-PAGE electrophoresis. No significant differences were determined between free-catch and urine sampled from the ground in cows. Giraffe urine was pale-yellow, with alkaline pH (>8.0) and a mean USG of 1.035 ± 0.013. The uTP, uCrea, and UPC expressed as median (range) were 0.20 (0.08-0.47) g/L, 2.36 (0.62-5.2) g/L, and 0.08 (0.05-0.15), respectively. SDS-PAGE allowed the separation of protein bands with different molecular masses, including putative uromodulin at 90 kD, putative albumin at 64 kD, and putative immunoglobulin heavy and light chains at 49 kD and 25 kD, respectively. Urine collection from the ground appears to be a reliable technique for urinalysis and urine electrophoresis in giraffes.
Collapse
|
13
|
Discordance of renal drug dosing using estimated creatinine clearance and measured urine creatinine clearance in hospitalized adults: A retrospective cohort study. Int J Crit Illn Inj Sci 2020; 10:1-5. [PMID: 33376682 PMCID: PMC7759072 DOI: 10.4103/ijciis.ijciis_61_19] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2019] [Revised: 01/16/2020] [Accepted: 02/14/2020] [Indexed: 01/03/2023] Open
Abstract
Background Assessment of kidney function is fundamental to optimize drug dosing. The Cockcroft-Gault (CG) equation is widely used but has questionable validity for females, changing renal function, and the critical ill. Eight-hour urine collections (U8h) offer direct measurement of creatinine clearance (CrCl) but lack the data for drug dosing. The primary objective of this study was to determine if there was a difference in renal drug dosing based on the estimation of CG CrCl (CrClCG) versus 8-h CrCl (CrCl8h). Methods This was an observational, retrospective cohort study of adult patients admitted between March 2018 and September 2018 with a collection U8h during hospitalization. The primary outcome was discordance of renal drug dosing defined as the percentage of U8h for which at least one different active medication CrCl dosing cutoff would result using the CrClCG versus CrCl8h. The secondary outcomes were correlation between CrClCG and CrCl8h and percentage of CrClCG values outside ± 20% of the CrCl8h. Results One hundred collections drawn from 85 unique patients (50.6% male, median age 55 [41-70] years, intensive care unit 88%) were included in the analysis. Median serum creatinine was 0.76 (0.52-1.06) mg/dL and blood urea nitrogen was 20 (14-28) mg/dL at time of collection8h. Median CrCl8h was 86.2 (43.5-140.3) mL/min versus 99.7 (56.5-166.9) mL/min CrClCG(P < 0.001) and discordance was 25%. The correlation between CrCl8h and CrClCG was 0.76 (P < 0.001). Only 31% of CrClCG values were within ± 20% of the CrCl8h value. Conclusion We found 25% discordance for drug dosing between CrCl8h and CrClCG. Further studies are needed to determine the impact on clinical outcomes.
Collapse
|
14
|
[Contamination of urine collected for cytobacteriological examination: situation in a university hospital in Morocco]. Ann Biol Clin (Paris) 2020; 78:139-146. [PMID: 32319942 DOI: 10.1684/abc.2020.1538] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The pre-analytical step of the cytobacteriological examination of urine (CBEU) is one of the most critical in microbiology. The objectives of our study were to determine the rate of urinary contamination and to analyze the factors that would facilitate this in order to propose solutions to this problem. METHOD This is a 26-month descriptive study including all CBEU requests to our laboratory. Urine was treated in accordance with the recommendations of the medical microbiology recommendations. Urine was considered contaminated in the case of polymorphic culture with at least three different types of germs with a count from 103 CFU/mL. RESULTS We collected 16,412 CBEU requests. Urine was contaminated in 4,830 cases (29.43%). Of the contaminated urine, 39.23% (n=1,895) was from emergency departments, 79.44% (n=3,837) was collected in the middle of the stream, 69.83% (n=3,373) was from a female patient and 16.34% (n=789) was from children under the age of 5. DISCUSSION AND CONCLUSION To reduce urine contamination, quality instructions describing sampling procedures should be available and samples in the middle of the stream and through the collection adhesive bags should be replaced by sus-pubic puncture samples in children, whenever the profit/risk ratio of this method is favourable.
Collapse
|
15
|
The Effect of Lemonade and Diet Lemonade Upon Urinary Parameters Affecting Calcium Urinary Stone Formation. J Endourol 2020; 33:160-166. [PMID: 30585747 DOI: 10.1089/end.2018.0623] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
PURPOSE To determine the effects of regular and diet lemonade upon urinary parameters affecting kidney stone formation. METHODS In this prospective blinded crossover study, 12 healthy participants consumed either 2 L of regular or diet lemonade daily while on a standardized low sodium moderate calcium diet. Twenty four-hour urine collections were obtained at baseline on the controlled diet only and on days 4 and 5 of each treatment phase. There was a 1-week washout period between regular and diet lemonade treatments. Primary outcomes were urine citrate, pH, and volume determined by 24-hour urine collections. Secondary outcomes included the supersaturation of calcium oxalate, calcium phosphate, and uric acid. RESULTS Urine volume was significantly higher with both regular and diet lemonade consumption compared with baseline values. Urinary citrate significantly increased from baseline with diet lemonade only. Urine pH was unchanged with both beverages. The supersaturation of calcium oxalate significantly decreased with diet lemonade only, whereas supersaturation of calcium phosphate decreased with both beverages. Daily consumption of 2 L of regular and diet lemonade resulted in an intake of 168.4 and 170.2 mEq of citrate but a total alkali intake of 12.2 and 16.0 mEq, respectively. Compared with diet lemonade, regular lemonade provided subjects with 805 additional calories and 225 g of sugar per day. CONCLUSIONS Diet lemonade may provide a low-calorie sugar-free cost-effective option for decreasing the risk of recurrent calcium nephrolithiasis through a significant increase in urine volume, increase in urinary citrate, and reduction in supersaturation of calcium oxalate and calcium phosphate.
Collapse
|
16
|
Development of objective indicators for quantitative analysis of sodium intake: the sodium to potassium ratio of second-void urine is correlated with 24-hour urinary sodium excretion. Nutr Res Pract 2020; 14:25-31. [PMID: 32042371 PMCID: PMC6997146 DOI: 10.4162/nrp.2020.14.1.25] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2019] [Revised: 05/19/2019] [Accepted: 08/13/2019] [Indexed: 01/26/2023] Open
Abstract
BACKGROUND/OBJECTIVES To date, sodium intake has been evaluated based on spot urine instead of 24-hour (hr) urine collection. Nevertheless, the optimal method for assessing daily sodium intake remains unclear. SUBJECTS/METHODS Fifteen male (age 32.7 ± 6.5 years) participants were offered 3 meals with a total of 9-10 g salt over 24 hours, and 24-hr urine was collected from the second-void urine of the first day to the first-void urine of the second day. Twenty-four-hr urinary sodium (24UNa) was estimated using Tanaka's equation and the Korean formula, and spot urine Na, potassium (K), chloride (Cl), urea nitrogen (UN), creatinine (Cr), specific gravity (SG) and osmolality (Osm) were measured. The ratios of urinary Na to other parameters were calculated, and correlations with total measured 24UNa were identified. RESULTS Average 24-hr urine volume was 1,403 ± 475 mL, and measured 24UNa was 143.9 ± 42.1 mEq (range, 87.1-239.4 mEq). Measured 24UNa was significantly correlated with urinary Na/UN (r = 0.560, P < 0.01), urinary Na/Osm (r = 0.510, P < 0.01), urinary Na/Cr (r = 0.392, P < 0.01), urinary Na/K (r = 0.290, P < 0.01), 24UNa estimated using Tanaka's equation (r = 0.452, P < 0.01) and the Korean formula (r = 0.414, P < 0.01), age (r = 0.548, P < 0.01), weight (r = 0.497, P < 0.01), and height (r = 0.393, P < 0.01) in all spot urine samples. Estimated 24UNa based on the second-void spot urine of the first day tended to be more closely correlated with measured 24UNa than were estimates from the other spot urine samples. The significant parameters correlated with the second-void urine of the first day were urinary Na/K (r = 0.647, P < 0.01), urinary Na/Cr (r = 0.558, P < 0.05), and estimated 24UNa using Tanaka's equation (r = 0.616, P < 0.05) and the Korean formula (r = 0.588, P < 0.05). CONCLUSIONS Second-void urine is more reliable than first-void urine for estimating 24UNa. Urinary Na/K in the second-void urine on the first day is significantly correlated with 24UNa. Further studies are needed to establish the most reliable index and the optimal time of urine sampling for predicting 24UNa.
Collapse
|
17
|
Identifying safe practices for use of the urinary leg bag drainage system in the postacute and long-term care setting: An integrative review. Am J Infect Control 2018; 46:973-979. [PMID: 30172338 DOI: 10.1016/j.ajic.2018.03.029] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2018] [Revised: 03/15/2018] [Accepted: 03/16/2018] [Indexed: 12/31/2022]
Abstract
BACKGROUND In the postacute and long-term care setting, the practice of changing the indwelling urinary catheter large sterile drainage bag to a small-size leg drainage bag is intended to maintain a person's mobility, dignity, and comfort. There is scant evidence that assesses the impact of intermittent use of a leg bag on frequency of urinary tract infection since this breaks the closed urinary drainage system. METHODS We reviewed research published between 1993 and 2014 for the answers to 20 practice questions developed by experts and long-term care clinicians on the risks and benefits, cleaning, connection, and storage of reusable leg bags. RESULTS Seventeen of the 26 publications and studies provided varying advice on the risk of breaking the closed system and on practices for changing, disinfecting, and storing leg bags between uses. Thirteen of 20 practice questions were answered by ≥1 publications, few of which were evidence based. CONCLUSIONS We identified the existence of low-level evidence that leg bags pose no evident, disproportionate risk of infection compared with maintaining a closed system. The lack of uniformity in evidence in the literature suggests aseptic technique should guide practice. Available evidence suggests that aseptic technique should guide practice.
Collapse
|
18
|
Abstract
Representative urine collection that respects the standards of animal welfare is still an issue in experimental nephrology. The commonly used metabolic cages induce stress in rodents. In mice, the volume of collected urine is sometimes insufficient for further analysis. The aim of this experiment was to analyse the effects of time of day, temperature and 2%, 5% or 10% sucrose solutions on diuresis, weight change and liquid intake of adult mice placed in metabolic cages for urine collection. Mice were placed in metabolic cages for 12 h during the day or night at standard ambient (22℃) and thermoneutral (28℃) temperatures. To determine the effect of acclimatisation, mice were placed in metabolic cages for five consecutive days. Diuresis increased with concentrations of sucrose. Body weight reduction was most rapid in the group given tap water and decreased with increasing sucrose concentrations. A drastic drop in body weight was observed in mice placed in metabolic cages for four consecutive days with access to tap water and food, indicating that time spent in metabolic cages should be kept to a minimum, as prolonged confinement in metabolic cages can be harmful to mice. The administration of concentrated sucrose solutions can potentially aid in mouse urine collection by reducing the time spent in metabolic cages. Sucrose supplementation increased the albumin/creatinine ratio. However, without showing estimates of glomerular filtration rate, renal haemodynamics, plasma electrolytes and urinary electrolyte excretions, the results of this study do not provide any conclusion about the effect of sucrose on renal function.
Collapse
|
19
|
Evaluation of cellulose pads as a method to detect cytomegalovirus DNA in neonatal urine. Ann Clin Biochem 2018; 55:553-560. [PMID: 29216741 DOI: 10.1177/0004563217750183] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Background Several approaches exist to screen neonates for congenital cytomegalovirus infection. We here describe a new method using cellulose pads for urine collection and its evaluation in an experimental and a clinical setting. Methods We systematically tested the effect of storage duration of the pads after exposure to cytomegalovirus-positive urine, meconium contamination and specimen handling on the cytomegalovirus load and the detection rate. Further, the method was tested in clinical practice in a cohort of 500 neonates. Results Following exposure of urine pads with cytomegalovirus-positive urine, the viral load decreased after 15 min, 12 h, 24 h, and 7 days to 63.2%, 42.1%, 31.6%, and 9.3% of the baseline value. Cytomegalovirus detection rate after seven days was 100%. Contamination with meconium resulted in a comparable reduction of the viral load. The detection rate for dried urine pads after seven days was 93.3%. In clinical practice, urine collection from pads was successful in 73.6% by the first attempt and in 26.4% by the second attempt. Conclusions Urine collection using cellulose pads seems feasible regardless of a reduction of the cytomegalovirus load due to exposure to the pad itself or to meconium. Drying of the exposed urine pad should be avoided.
Collapse
|
20
|
Repetitive urine and blood sampling in neonatal and weaned piglets for pharmacokinetic and pharmacodynamic modelling in drug discovery: a pilot study. Lab Anim 2017; 51:498-508. [PMID: 28178895 DOI: 10.1177/0023677217692372] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Piglets are considered to be suitable animal models for predicting the pharmacokinetics and pharmacodynamics (PK/PD) of test drugs for potential use in the paediatric population. Such PK/PD studies require multiple blood and urine samplings. The goal of the present study was to determine a suitable blood collection strategy applicable in the youngest age categories of six days, four weeks and eight weeks of age, as well as a urine collection technique for male piglets in the same age categories. Blood was collected either by a surgically-placed jugular vein catheter (six days old [ n = 4] and four weeks old [ n = 2] piglets) or by direct venepuncture of the jugular vein (four weeks old [ n = 2] and eight weeks old [ n = 4] piglets). A non-invasive method for total volume urine collection in male piglets was also developed using a urine pouch. No specific complications were encountered during anaesthesia or surgery for jugular catheter placement. After a 24 h recovery period, urine and blood were easily collected without technical complications. One piglet was humanely killed at week 2 because of septicaemia. Histological analysis of both veins in all four piglets revealed negligible damage to the blood vessel wall. In conclusion, the presented techniques for blood (jugular catheter and direct venepuncture) and urine collection (pouches) are suitable for PK/PD studies in piglets.
Collapse
|
21
|
Hepcidin on 24-hour urine collection: preanalytical aspects and correlation with ferritin levels. Scandinavian Journal of Clinical and Laboratory Investigation 2016; 76:454-9. [PMID: 27284811 DOI: 10.1080/00365513.2016.1190864] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
BACKGROUND Urine hepcidin measurement is a potential non-invasive tool for assessing iron stores. However, hepcidin, due to its amphipathic structure, tends to aggregate and to adhere to surfaces in a protein-poor environment. In this study, we assessed the effect of solid bovine serum albumin (BSA) at different final concentrations (0, 2.5 or 5 g/L) in limiting the loss of hepcidin in spot urine samples. We also explored how hepcidin measured on plasma, spot or 24-hour urine collections can identify iron deficiency. METHODS Hepcidin levels were quantified on plasma, spot (with or without BSA) or 24-h urine collections for 33 volunteers. Hematological and iron status parameters were measured for each individual. The ability to detect iron deficiency (defined as a ferritin level <30 μg/L) based on plasma, spot or 24-h urine collections hepcidin levels was assessed by the means of receiver operator curves analysis. RESULTS The addition of BSA into urine prior to sample collection prevented hepcidin loss by 13.3% (mean) in spot urine samples whatever the amount. The areas under the receiver operator curves obtained for detecting iron deficiency were respectively 0.94 and 0.93 for hepcidin levels obtained on plasma and 24-h urine collections. CONCLUSION In this study, we showed that the addition of solid BSA into urine sample collection containers could prevent aggregation of hepcidin and that 24-h urine hepcidin levels could be as efficient as plasma concentrations for identifying iron deficiency.
Collapse
|
22
|
The association between cognitive function and objective adherence to dietary sodium guidelines in patients with heart failure. Patient Prefer Adherence 2016; 10:233-41. [PMID: 27042017 PMCID: PMC4780397 DOI: 10.2147/ppa.s95528] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Abstract
BACKGROUND Although cognitive impairment is common in heart failure (HF) patients, its effects on sodium adherence recommendations are unknown. PURPOSE Our aim is to examine if cognitive function is associated with patient sodium adherence. METHODS Sodium collection/excretion and cognitive function were assessed for 339 HF patients over a 5-8-week period. Neuropsychological testing was performed at baseline (Visit 1), whereas two 24-hour urine samples were collected within 7 weeks postbaseline. The ability to collect two 24-hour urine samples and the estimation of sodium excretion levels from these samples were used to estimate sodium adherence recommendations. RESULTS Nearly half (47%) of the study participants (n=159) were unable to give two valid 24-hour urine samples. Participants who were unable to adhere to two valid 24-hour urine samples had significantly poorer attention and global cognition tests (P<0.044), with a trend for poorer executive function (P=0.064). Among those with valid samples, urine sodium level was not associated with global cognitive function, attention, executive function, or memory after adjusting for covariates. Female sex was associated with lower sodium excretion (all P<0.01); individuals with knowledge of sodium guidelines had less intake of sodium, resulting in excretion of less sodium (all P≤0.03). Conversely, higher socioeconomic status (SES) and body mass index (BMI) were associated with greater sodium (all P≤0.02 and P≤0.01). CONCLUSION Adherence to urine sodium collection was poor, especially among those with poorer cognitive function. Sodium consumption exceeded recommended amounts and was unrelated to cognitive function. Interventions for improving sodium adherence should focus on at-risk groups (high SES and BMI) and at improving knowledge of recommended salt intake.
Collapse
|
23
|
Abstract
On May 5, 1961, astronaut Alan Shepard became the first American to fly in space. Although National Aeronautics and Space Administration (NASA) had discounted the need for him to urinate, Shepard did, in his spacesuit, short circuiting his electronic biosensors. With the development of the pressure suit needed for high-altitude and space flight during the 1950s, technicians had developed the means for urine collection. However, cultural mores, combined with a lack of interagency communication, and the technical difficulties of spaceflight made human waste collection a difficult task. Despite the difficulties, technicians at NASA created a successful urine collection device that John Glenn wore on the first Mercury orbital flight on February 20, 1962. With minor modifications, male astronauts used this system to collect urine until the Space Shuttle program. John Glenn's urine collection device is at the National Air and Space Museum and has been on view to the public since 1976.
Collapse
|